1. Typical Frequency Response Frequency in Hz 10 1000 100000 Phase Shift in Degrees 3 20 Typical Accuracy Curve 2 00 1 50 1 00 0 50 50 mA 0 00 5 10 15 20 25 30 0 50 Error of Reading 1 00 1 50 2 00 Current Measurement Switch on the probe using the On Off switch and check that the LED is lit 2 Connect the output lead to an oscilloscope multimeter or other measuring equipment 3 lf necessary adjust the probe output voltage to zero as described in section Zero Adjustment 4 Clamp the jaw of the probe around the conductor ensuring a good contact between the closing faces of the jaws 5 Observe and take measurements as required Positive output indicates that the current flow is in the direction shown by the arrow on the probe Subject to change without notice Battery Replacement Warning N To avoid personal injury always ensure the probe is removed from any live electric circuit and leads are disconnected before removing the battery co ver Never operate the probe without the battery cover fitted The red LED will flash when the minimum operating voltage is approached Refer to Fig 1 Use the following procedure 1 Unclamp the probe
2. Instrucciones de seguridad Lea esta secci n con atenci n Le familiarizar con las ins trucciones de seguridad m s importantes para la manipula ci n del producto En esta hoja de instrucciones una leyenda de Advertencia identifica condiciones y acciones que repre sentan riesgols para el usuario Una leyenda de Precauci n identifica condiciones y acciones que podr an da ar al calib rador o a los instrumentos de comprobaci n S mbolo Descripci n No se deshaga de este producto como un residuo Y normal utilizando los servicios municipales P ngase en contacto con HAMEG o con un agente de reciclado de residuos autorizado Informaci n importante Consulte el manual Doble aislamiento Nota La leyenda Este es un sensor de corriente tipo A indica que se puede aplicar en torno a conductores energizados peligrosos y su retirarla de los mismos BS ap Satisface las normas de la Canadian Standards Association o e y TY 52 Se ajusta a los requisitos de la Uni n Europea y de la European Union and European Free Trade Association EFTA M Mm 28 Reservado el derecho de modificaci n Advertencia N La pinza HZ56 2 deben ser utilizados y manipula dos nicamente por personal calificado Para evitar lesiones personales guarde estas precauciones Para evitar descargas el ctricas tenga cuidado durante la instalaci n y el empleo de este producto en el circu
3. 1 24 jot HI al Zunahme in dB LH Il 3 Typischer Frequenzgang Frequenz in Hz 10 1000 100000 5 mt 20 Phasenverschiebung in Grad 3 Typische Genauigkeit 2 00 1 50 1 00 0 50 50 mA 0 00 5 10 15 20 25 30 0 50 Messfehler 1 00 1 50 2 00 zu stellen das Daumenrad nach unten dr cken und drehen Sicherstellen dass die Sonde wahrend der Nullstellung von stromf hrenden Leitern getrennt ist Strommessung 1 Die Sonde unter Verwendung des EIN AUS Schalters ein schalten und pr fen ob die LED leuchtet 2 Die Ausgangsmessleitung an ein Oszilloskop Multimeter oder anderes Messger t anschlie en 3 N tigenfalls die Sondenausgangsspannung gem Be schreibung in Abschnitt Nullung auf Null stellen nderungen vorbehalten gt Die Backen der Sonde um den Leiter klemmen und guten Kontakt zwischen den Schlie fl chen der Backen sicher stellen Nach Bedarf das Ger t beobachten und Messungen durchf hren Positiver Ausgang gibt an dass der Strom in die durch den Pfeil auf der Sonde a
4. 290g Operating Instructions LED Zero Adjust Battery Cover ON OFF Switch Protective Barrier Jaws 10000000 Battery Cover Screw Captive Fig 1 HZ56 2 Warning N To avoid injury when using the probe ensure that your fingers are behind the protective barrier as shown in Figure 1 Do not use the probe if any part of the probe including the lead and connector s appear to be damaged or if a malfunction of the instrument is suspected Clean the case periodically by wiping it with a damp cloth and detergent Do not use abrasive cleaners or solvents Do not immerse the probe in liquids Switch On When the probe is switched on the red LED will illuminate The LED starts flashing when the battery voltage is too low for normal operation and warns the user that it requires changing This procedure is described below Zero Adjustment The output zero offset voltage of the probe may change due to thermal shifts and other environmental conditions To ad just the output voltage to zero depress the thumbwheel and rotate Ensure that the probe is away from the current carry ing conductor whilst the adjustment is made Subject to change without notice Typical performance Plots Typical Frequency Response Frequency in Hz 10 1000 100000 o Begny H Gain in dB
5. tier r guli rement en l essuyant avec un chif fon imbib de d tergent N utilisez ni solvants ni produits de nettoyage abrasifs Ne plongez pas la sonde dans un li quide Mise sous tension Le voyant rouge s allume lorsque la sonde est activ e Le voyant se met a clignoter lorsque la tension de la pile est trop faible il avertit l utilisateur que la pile doit tre remplac e pour le bon fonction nement de la sonde Cette proc dure est d crite ci dessous R glage du z ro La tension du d calage du z ro en sortie de la sonde peut varier en fonction des d calages thermiques et d autres con Sous r serve de modifications Courbes de performances typiques R ponse typique en fr quence Fr quence en Hz 10 1000 100000 a TD s 2 H I 3 TT R ponse typique en fr quence Fr quence en Hz 10 1000 100000 0 D phasage en degr s A 20 Courbe de pr cision typique 2 00 1 50 1 00 0 50 50 mA 0 00 5 10 15 20 25 30 0 50 1 00 Erreur de lecture 1 50 2 00 ditions ambiante
6. Este procedimien to se describe m s abajo Ajuste del cero La indicaci n de voltaje cero en la salida de la sonda puede variar debido a corrimientos t rmicos y otras condiciones ambientales Para ajustar el voltaje de salida a cero pre Reservado el derecho de modificaci n Gr ficos t picos de desempe o Respuesta t pica de frecuencia Frecuencia en Hz 10 1000 100000 TT IN mM 0 1 24 jo HI Ganancia en dB LH U 3 Respuesta t pica de frecuencia Frecuencia en Hz 10 1000 100000 o Desplazamiento de fase en grados a Z D Curva t pica de exactitud 2 00 1 50 1 00 0 50 50 mA 0 00 5 10 15 20 25 30 0 50 1 00 Error de lectura 1 50 2 00 sione la ruedecilla y g rela Aseg rese de que mientras se realiza el ajuste la sonda se encuentre alejada del conductor que transporta la corriente Medici n de corriente 1 Encienda la sonda por medio del interruptor de Encendi do Apagado y verifique que el LED est iluminado 2 Conecte el cable de salida a un osciloscopio mul
7. besch digen k nnen Symbol Beschreibung Dieses Produkt nicht in unsortiertem Kommunal X abfall entsorgen Zur Entsorgung mit HAMEG Instruments GmbH oder einer qualifizierten Recycling Einrichtung Kontakt aufnehmen Wichtige Informationen Siehe Handbuch Schutzisolierung Hinweis Dies ist ein Typ A Stromsensor Anwendung in der Umgebung von gef hrlichen stromf hrenden Leitern zul ssig Sa gt Ubereinstimmung mit Canadian Standards Association o Ba Stimmt berein mit den Anforderungen der EU European Union und der EFTA European Free Trade Association MM Mm 4 Anderungen vorbehalten Warnung N Die Stromzange HZ56 2 darf nur durch Fachper sonal bedient werden Zur Vermeidung von Verlet zungen folgende Vorsichtsma nahmen beachten Zur Vermeidung von Stromschlag w hrend der Instal lation und Verwendung dieses Produkts vorsichtig vor gehen im zu pr fenden Stromkreis k nnen gef hrliche Spannungen und Str me vorhanden sein Das Produkt nicht verwenden wenn es besch digt ist Stets die Sonde am Anzeigeger t anschlie en und erst dann um den Leiter installieren Vor Entfernung der Batteriefachabdeckung stets si cherstellen dass die Sonde von allen stromf hrenden elektrischen Schaltkreisen getrennt ist und die Messlei tungen getrennt sind Die Stromzange nur wie in den Betriebsanleitungen an gegeben verwenden da der Schutz des Bedieners
8. durch die Sicherheitseinrichtungen der Stromzange sonst nicht gew hrleistet ist Lokale und landesweite Sicherheitsvorschriften einhal ten Wo gef hrliche stromf hrende Leiter freiliegen muss pers nliche Schutzausr stung zur Vermeidung von Verletzung durch Stromschlag und Lichtbogenent ladung verwendet werden Die Stromzange nicht vor dem Griffschutz halten Die Stromzange vor jedem Gebrauch untersuchen Das Stromzangengeh use und die Ausgangskabelisolierung auf Risse oder fehlenden Kunststoff pr fen Auch nach losen oder verschlissenen Komponenten suchen Die Isolierung im Bereich der Backen besonders sorgf ltig untersuchen Bei Arbeiten mit Spannungen ber 60 V Gleichspannung oder 30 V Wechselspannung eff oder 42 V Wechselspan nung Spitze Vorsicht walten lassen Solche Spannungen bergen Stromschlaggefahr Diese Ausr stung ist so konzipiert dass sie Schutz ge gen impulsf rmige St rsignale in fest installierten An lagen bietet beispielsweise in Verteilertafeln Zulei tungen und kurzen Verzweigungsstromkreisen sowie in Beleuchtungssystemen gro er Geb ude Die Verwendung dieses Ger t in einer anderen hier nicht aufgef hrten Art und Weise kann den Eigenschutz des Ger ts beeintr chtigen CAT IIl Ausr stung ist so konzipiert dass sie Schutz ge gen die impulsf rmigen St rsignale in fest installierten nderungen vorbehalten Anlagen bietet beispielsweise in Verteilertafeln Zulei tungen und
9. tipo de bater a distinto del especificado invalidar la garant a Coloque nica mente una bater a PP3 alcalina de 9 V MN 1604 Reservado el derecho de modificaci n HAMEL Instruments A Rohde amp Schwarz Company Oscilloscopes Spectrum Analyzer Power Supplies Modular System P rr Series 8000 uns Programmable Instruments Series 8100 authorized dealer 47 0056 0240 www hameg com Subject to change without notice 47 0056 0240 02032009 HAMEG Instruments GmbH HAMEG Instruments GmbH IndustriestraBe 6 A Rohde amp Schwarz Company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certification DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg com
10. vie Caract ristiques g n rales Calibre de conducteur maximum Branchements et c ble de sortie Z ro de sortie Plage de temp ratures de fonctionnement Plage de temp ratures d entreposage Poids 20 Aac eff ou DC 30A 500A 100 mV A 1 du r sultat 2 mA 1 mA 200 uVeff gt 100k0 lt 100 pF 1 par rapport a la lecture centrale DC jusqu 100 kHz 0 5 dB 20A ps mieux que 1 us 0 01 du r sultat C 15 85 sans condensation 2000 m 9 V alcaline NEDA 1604 PP3 IEC 6LR61 300 Vac eff ou DC 30 heures indicateur de pile faible Diam tre de 19 mm C ble de 2 m termin par un connecteur BNC 50 ohms ourni avec un adaptateur de s curit de 4 mm R glage manuel avec molet 0 50 C 20 85 C sans la pile 290g Sous r serve de modifications Consignes d utilisation O DEL O R glage du z ro O Couvercle de pile Interrupteur marche arr t Collerette de s curit M choire Vis imperdable du couvercle de pile Figure 1 HZ56 2 Avertissement Pour viter les blessures en utilisant la sonde veiller a positionner les doigts derri re la colle rette de s curit conform ment a la figure 1 Ne pas utiliser la sonde si l un de ses l ments semble endommag y compris ses cordons et ses connecteurs ou si un dysfonctionnement de Uinstrument est suspect Nettoyez le bo
11. vis de fixation imperdable du couvercle de pile Soulevez le couvercle de 30 et retirez le du corps de la sonde conform ment la figure 1 La pile est alors accessible Remplacez la pile et replacez son couvercle puis serrez la vis Remarque L installation d un type de pile autre que celui sp cifi annule la garantie Installez uniquement la pile alcaline 9 V de type PP3 MN 1604 Sous r serve de modifications Indice Deutsch 4 English 12 Francais 20 ntroducci n 28 nstrucciones de seguridad 28 Garant a y reparaciones 30 Datos T cnicos 31 nstrucciones de operaci n 32 edici n de corriente 33 Gr ficos t picos de desempe o 33 Reemplazo de la bater a 34 Reservado el derecho de modificaci n Introducci n La pinza amperim trica HZ56 2 para CA y CD ha sido dise ada para emplearla con osciloscopios y multimetros digi tales para permitir mediciones exactas y no intrusivas tanto de CA CD como de corrientes de formas de onda complejas Mediante una avanzada tecnolog a de efecto Hall la HZ56 2 puede medir corrientes de manera exacta con una resoluci n de 1 mA entre 5 mA y 30 A en un Margen de frecuencias que va desde CD hasta los 100 kHz Estas caracter sticas hacen de ella una potente herramienta para ser utilizada en inver sores fuentes de alimentaci n con modo de conmutaci n controladores industriales y otras aplicaciones que requier an mediciones de corriente y o an lisis de formas de onda
12. 0 kHz 0 5 dB 20A ps inferior a 1 ys 0 01 de la lectura C 85 sin condensaci n 2000 m Alcalina de 9 V EDA 1604 PP3 IEC 6LR61 ormas de seguridad 300 Vac eff o DC horas ndicador de bateria baja 19 mm de diametro Cable de 2 m terminado con un conector BNC 50 ohmios provisto de un adaptador de seguridad de 4 mm Ajuste manual mediante una ruedecilla 0 a 50 C Me 859 con bater a extra da 290g Instrucciones de operaci n 6 O Cubierta de la bater a Llave de ENCEN DIDO APAGADO Barrera protectora 5 Mordazas Tornillo de la cubierta de la bater a cautivo UI Figura 1 HZ56 2 Advertencia Para evitar lesiones cuando use la sonda aseg rese de que los dedos quedan detr s de la barrera de protecci n como se muestra en la figura 1 No utilice la sonda si alguna de las partes incluido el conductor y los conectores presentan da os o si se sospecha que el instrumento no funciona correctamente Limpie la caja peri dicamente pas ndole un pa o h medo y detergente No utilice disolventes o limpiadores abrasivos No sumerja la sonda en l quidos Encendido Cuando la sonda se encienda se iluminar el LED rojo Cuan do el voltaje de la la bater a sea demasiado bajo para la opera ci n normal el LED comenzar a destellar para advertir al usuario de que se requiere reemplazarla
13. HAMEL Instruments A Rohde amp Schwarz Company AC DC Current Clamps HZ56 2 Handbuch Manual Manuel Manual Deutsch English Francais Espa ol Inhalt English 12 Francais 20 Espa ol 28 Einf hrung Sicherheitsanleitungen Gewahrleistung und Reparatur Technische Daten Bedienung und Handhabung Strommessung Typische Leistungskurven Ersetzen der Batterien COD ANAR gt Anderungen vorbehalten Einf hrung Die HZ56 2 AC DC Stromzange wurde fur den Gebrauch mit Oszilloskopen und DMMs fir exakte ber hrungsfreie Wech sel und Gleichstrommessungen und zum Messen komplexer Stromsignalformen konzipiert Mit erweiterter Hall Effekt Technologie liefert die Stromzange exakte Strommessungen im Gleichstromfrequenzbereich bis 100 kHz mit einer Auf l sung von 1 mA von 5 mA bis 30 A Diese Merkmale ma chen das Ger t zu einem leistungsf higen Werkzeug fur die Verwendung mit Wechselrichtern Schaltnetzteilen Indus triesteuerungen und anderen Anwendungen die Strommes sungen und oder Signalanalysen erfordern Sicherheitsanleitungen Diesen Abschnitt sorgf ltig durchlesen Der Abschnitt erl u tert die wichtigsten Sicherheitsanleitungen zur Handhabung des Produkts Ein Warnhinweis in diesem Einf hrungsblatt signalisiert Bedingungen und Handlungen die f r den Be diener gefahrlich sind Ein Vorsichtshinweis kennzeichnet Bedingungen und Handlungen die den verwendeten Kali brator oder die Messger te
14. a RMA number either by internet http www hameg com or fax If you do not have an original shipping carton you may obtain one by calling the HAMEG service dept 49 6182 800 500 or by sending an email to service hameg com Subject to change without notice Specifications Electrical Characteristics all accuracies stated at 23 C 1 C Current range Measuring range Overload capacity Output sensitivity Accuracy at 25 C Resolution Typical output noise level Load impedance Conductor position sensitivity Frequency range di dt following Response time Temperature coefficient Operating humidity Altitude Power supply Working voltage see Safety Standards Battery life General Characteristics Maximum conductor size Output cable connections Output zero Operating temp range Storage temperature range with battery removed Weight Subject to change without notice 20 Aacrms or DC 0A DA 0 mV A of reading 2 mA mA 200 uV rms gt 100 kO lt 100 pF 1 relative to center reading DC to 100 kHz 0 5 dB 20A ps better than 1 us 0 01 of reading C 15 to 85 non condensing 2000 m 9 V Alkaline NEDA 1604 PP3 IEC 6LR61 wo ine E O Ni 300 Var rms or DC 30 hours low battery indicator 19 mm diameter 2 m cable terminated with a BNC connector 50 Ohms supplied with a 4 mm safety adaptor Manual adjust via thumbwheel 0 to 50 C 20 to 85 C
15. ans les installations d quipements fixes notamment sur les panneaux de distribution lectrique les lignes d alimentation et les circuits d riv s courts ainsi que les installations d clairage dans les grands batiments Cet appareil doit tre utilis dans les conditions sp cifi es afin de ne pas entraver la s curit intrinseque assur e par l appareil Les appareils CAT Ill sont con us pour prot ger contre les tensions transitoires dans les installations d quipements fixes notamment sur les panneaux de distribution lec Sous r serve de modifications trique les lignes d alimentation et les circuits d riv s courts ainsi que les installations d clairage dans les grands b timents Normes de s curit BS EN 61010 1 BS EN 61010 2 032 BS EN 61010 031 CSA C22 2 No 1010 1 Cat gorie Ill sur les surtensions de 300 Veff degr de pollution 2 L utilisation de la sonde sur des conducteurs non isol s est limit e jusqu a 300 V c aeff ou c c et aux fr quences inf ri eures a 1 kHz Normes CEM BS EN 61326 A1 A2 et A3 Garantie et r peration Les instruments HAMEG sont soumis a un contr le quali t tres s vere Chaque appareil subit un test burn in de 10 heures avant de quitter la production lequel permet de d tecter pratiquement chaque panne pr matur e lors d un fonctionnement intermittent L appareil est ensuite soumis a un essai de fonctionnement et de qualit approfondi au cours du
16. dustriels et d autres applications exigeant des mesures de courant et ou une analyse des formes d ondes Consignes de s curit Veuillez lire cette section attentivement Elle vous permet tra de vous familiariser avec les consignes de s curit les plus importantes lors de l utilisation de l appareil Un Aver tissement indique des situations et des actions qui pr sentent des dangers pour l utilisateur Une mise en garde Attention indique des situations et des actions qui risquent d endommager le calibrateur ou les instruments de test Symbole Description Ne pas mettre ce produit au rebut avec les d chets X m nagers Contacter HAMEG ou un centre de recyc lage qualifi pour sa mise au rebut Informations importantes Se reporter au manuel Double isolation Remarque Ce capteur de courant de type A est con u pour tre appliqu ou enlev sur des conducteurs sous tension dangereuse BS ap Conforme l association canadienne de normalisation ACNOR a D 509 Conforme aux directives de l Union europ enne et de Association europ enne de libre change AELE M Mm 20 Sous r serve de modifications Avertissement La pince amp rem trique HZ56 2 ne doivent tre utilis es et manipul es que par un personnel qualifi Pour viter les blessures respecter les pr cautions suivantes Pour viter les risques d lectrocution proc der avec prudence penda
17. e protection provided by the equipment CAT Ill equipment is designed to protect against the tran sients in the equipment in fixed equipment installations such as distribution panels feeders and short branch circuits and the lighting systems in large buildings Subject to change without notice Safety Standards BS EN 61010 1 BS EN 61010 2 032 BS EN 61010 031 CSA C22 2 No 1010 1 300 V rms Category Ill Pollution degree 2 Use of the probe on uninsulated conductors is limited to 300 Vac rms or DC and frequencies below 1 kHz EMC Standards BS EN 61326 A1 A2 and AS Warranty and Repair HAMEG instruments are subjected to a strict quality control Prior to leaving the factory each instrument is burnt in for 10 hours By intermittent operation during this period almost all defects are detected Following the burn in each instru ment is tested for function and quality the specifications are checked in all operating modes the test gear is calibrated to national standards The warranty standards applicable are those of the country in which the instrument was sold Reclamations should be directed to the dealer Only valid in EU countries In order to speed reclamations customers in EU countries may also contact HAMEG directly Also after the warranty expired the HAMEG service will be at your disposal for any repairs Return material authorization RMA Prior to returning an instrument to HAMEG ask for
18. en designed for use with oscilloscopes and DMMs for accurate non intru sive measurement of both AC DC and complex waveform currents Using advanced Hall Effect technology the HZ56 2 can accurately measure currents with a resolution of 1 mA from 5 mA to 30 A over the frequency range of DC to 100 kHz These features make it a powerful tool for use in inverters switch mode power supplies industrial controllers and other applications requiring current measurements and or wave form analysis Safety Instructions Please read this section carefully It will make you familiar with the most important safety instructions for handling your product In this instruction sheet a Warning identifies condi tions and actions that pose hazardls to the user A Caution identifies conditions and actions that may damage the calib rator or the test instruments Warning The HZ56 2 may only be used and handled by qua lified personnel To avoid personal injury follow these precautions Symbol Description Do not dispose of this product as unsorted municipal X waste Contact HAMEG Instruments GmbH or a qualified recycler for disposal Important Information See manual Double insulation Do not apply around or remove from the HAZARDOUS LIVE conductors Gn bp Conforms to Canadian Standards Association a E 59 Complies with the relevant European standards Mm m 12 Subject to change without
19. from the conductor turn it off using the On Off switch and disconnect the output leads from external equipment 2 Loosen the captive screw that secures the battery cover Lift the cover through 30 and pull it clear of the probe body as shown in Fig 1 The battery is then accessible Replace the battery and re fit the battery cover and fasten the screw Note Replacement with other than the specified type of battery will invalidate the warranty Fit only the type 9 V PP3 Alkaline MN 1604 Subject to change without notice Table des mati res Deutsch 4 English 12 Espa ol 28 Francais Introduction 20 Consignes de s curit 20 Garantie et r peration 22 Caract ristiques g n rales 23 Consignes d utilisation 24 Courbes de performances typiques 25 Remplacement de la pile 26 Sous r serve de modifications Introduction La pince amp rem trique HZ56 2 AC DC est destin e aux oscilloscopes et aux multim tres num riques pour effectuer des mesures pr cises non intrusives des courants continus et alternatifs et des formes d ondes complexes L utilisation de la technologie de l effet de Hall permet la pince HZ56 2 de mesurer avec pr cision des courants entre 5 mA et 30 A avec une r solution de 1 mA sur la gamme des fr quences de courant continu jusqu a 100 kHz Ces fonctions font de la pince un outil puissant utilis dans les inverseurs les ali mentations lectriques a mode commut les r gulateurs in
20. ito en comprobaci n puede haber presentes voltajes y corri entes altos No utilice este producto si tiene alg n da o Conecte siempre la sonda a la pantalla antes de instalarla en torno del conductor Siempre aseg rese de que antes de retirar la cubierta de la bater a la sonda sea retirada y los cables sean descon ectados de todo circuito el ctrico energizado Utilice la sonda de corriente s lo siguiendo las especifi caciones de las instrucciones de funcionamiento en caso contrario puede que las funciones de seguridad de la sonda de corriente no le protejan Siga los c digos de seguridad locales y nacionales En lugares donde haya conductores energizados expuestos se debe utilizar equipo de protecci n individual para evi tar lesiones por descargas el ctricas y arcos No sujete la sonda de corriente por ning n sitio que no sea el indicador t ctil Antes de cada uso inspeccione la sonda de corriente Busque posibles roturas o piezas que falten en el aloja miento de la sonda o en el aislante del cable de salida Aseg rese tambi n de que no haya componentes sueltos o flojos Preste especial atenci n al aislamiento que rodea las mordazas Tenga cuidado al trabajar con tensiones superiores a 60 V CC 30 V CA valor eficaz o 42 V CA pico Estas ten siones representan un riesgo de descargas el ctricas Estos equipos est n dise ados para proteger contra tran sitorios en los equipos empleados en instalacio
21. kurzen Verzweigungsstromkreisen sowie in Beleuchtungssystemen gro er Geb ude Sicherheitsstandards BS EN 61010 1 BS EN 61010 2 032 BS EN 61010 031 CSA C22 2 Nr 1010 1 300 Veff Kategorie III Verschmutzungs grad 2 Der Gebrauch der Sonde an unisolierten Leitern ist auf 300 V AC eff oder DC und Frequenzen unterhalb 1 kHz beschr nkt EMV Standards BS EN 61326 A1 A2 und A3 Gewahrleistung und Reparatur HAMEG Gerate unterliegen einer strengen Qualitatskontrol le Jedes Gerat durchlauft vor dem Verlassen der Produktion einen 10 st ndigen Burn in Test Im intermittierenden Be trieb wird dabei fast jeder Fr hausfall erkannt AnschlieBend erfolgt ein umfangreicher Funktions und Qualit tstest bei dem alle Betriebsarten und die Einhaltung der technischen Daten gepruft werden Die Pr fung erfolgt mit Pr fmitteln die auf nationale Normale r ckf hrbar kalibriert sind Es gelten die gesetzlichen Gewahrleistungsbestimmungen des Landes in dem das HAMEG Produkt erworben wurde Bei Beanstandungen wenden Sie sich bitte an den Handler bei dem Sie das HAMEG Produkt erworben haben Nur f r die Lander der EU Um den Ablauf zu beschleunigen k nnen Kunden innerhalb der EU die Reparaturen auch direkt mit HAMEG abwickeln Auch nach Ablauf der Gew hrleistungsfrist steht Ihnen der HAMEG Kundenservice f r Reparaturen zur Verf gung Return Material Authorization RMA Bevor Sie ein Ger t an uns zur cksenden fordern Sie bi
22. la UE pueden dirigirse directamente a Ha meg para acelerar sus reparaciones El servicio t cnico de Hameg tambi n estar a su disposici n despu s del per odo de garant a Return Material Authorization RMA Por favor solicite un n mero RMA por internet o fax antes de reenviar un equipo Si no dispone de un embalaje adecuado puede pedir un cart n original vac o de nuestro servicio de ventas Tel 49 0 6182 800 500 E Mail service hameg com Reservado el derecho de modificaci n DATOS TECNICOS Caracter sticas el ctricas Todos los valores exactos se especifican a 23 C 1 C Margen de corriente Margen de medicion Capacidad de sobrecarga Sensibilidad de la salida Exactitud a 25 C Resolucion Nivel tipico del ruido de salida Impedancia de carga Sensibilidad de la posicion de los conductores Margen de frecuencia Seguimiento de di dt Tiempo de respuesta Coeficiente de temperatura Humedad de funcionamiento Altitud Alimentacion Voltaje de operaci n consulte Duraci n de la bater a Caracter sticas generales Tama o m ximo de los conductores Cable de salida y conexiones Puesta a cero de la salida Margen de temperaturas de operaci n Margen de temperaturas de almacenamiento Peso Reservado el derecho de modificaci n 20 Are rms o DC 30A 500A 100 mV A 1 de la lectura 2 mA 1 mA 200 uV rms gt 100 kO lt 100 pF 1 relativa a la lectura del centro DC a 10
23. nes de equipo fijo tales como los paneles de distribuci n ali mentadores circuitos de ramales cortos y los sistemas de iluminaci n de grandes edificios El uso de este equipo de manera no especificada aqui podr a afectar a la protecci n que proporciona Los equipos de la categor a CAT III est n dise ados para proteger contra transitorios en los equipos empleados en instalaciones de equipo fijo tales como los paneles de distribuci n alimentadores circuitos de ramales cortos y los sistemas de iluminaci n de grandes edificios Reservado el derecho de modificaci n Normas de seguridad BS EN 61010 1 BS EN 61010 2 032 BS EN 61010 031 CSA 022 2 N 1010 1 300 Vams categor a Ill grado de poluci n 2 El empleo de la sonda en conductores no aislados est limi tado a 300 V ACRMS o CD y frecuencias por debajo de 1 kHz Normas EMC BS EN 61326 A1 A2 y A3 Garant a y reparaciones Su equipo de medida HAMEG ha sido fabricado con la m xi ma diligencia y ha sido comprobado antes de su entrega por nuestro departamento de control de calidad pasando por una comprobaci n de fatiga intermitente de 10 horas A con tinuaci n se han controlado en un test intensivo de calidad todas las funciones y los datos t cnicos Son v lidas las normas de garant a del pa s en el que se ad quiri el producto de HAMEG Por favor contacte su distribui dor si tiene alguna reclamaci n S lo para los paises de la UE Los clientes de
24. ngegebene Richtung flie t Ersetzen der Batterien Warnung N Zur Vermeidung von Stromschlag vor Entfernen der Batteriefachabdeckung stets sicherstel len dass die Sonde von allen stromf hrenden elektrischen Schaltkreisen getrennt ist und die Messleitungen entfernt sind Die Sonde niemals ohne ordnungsgem angebrachte Abdeckung betreiben Die rote LED blinkt bei Ann herung an die minimale Be triebsspannung Siehe Abbildung 1 Folgendes Verfahren anwenden I Die Sonde vom Leiter trennen das Ger t unter Verwen dung des EIN AUS Schalters ausschalten und die Aus gangsmessleitungen von externen Ger ten trennen Die unverlierbare Schraube l sen die die Batteriefachab deckung befestigt Die Abdeckung 30 anheben und vom Sondengeh use wegziehen siehe Bild 1 Die Batterie ist jetzt zug nglich Die Batterie ersetzen und die Batte riefachabdeckung wieder anbringen und mit der Schrau be befestigen Hinweis Ersatz durch einen nicht spezifizierten Batterietyp macht die Garantie nichtig Ausschlie lich 9 V PP3 Alkalibatterie MN 1604 verwenden nderungen vorbehalten Content Deutsch 4 Francais 20 Espa ol 28 English Introduction Safety Instructions Warranty and Repair Specifications Operating Instructions Current Measurement Typical performance Plots Battery Replacement a 3 a GO JJOs01P NN Subject to change without notice Introduction The HZ56 2 AC DC Current Clamp has be
25. notice To avoid electric shock use caution during installation and use of this product high voltages and currents may be present in circuit under test Do not use the product if damaged Always connect pro be to display device before it is installed around the con ductor Always ensure the probe is removed from any live elec tric circuit and leads are disconnected before removing the battery cover Use the Current Probe only as specified in the operating instructions otherwise the current probe s safety fea tures may not protect you Adhere to local and national safety codes Individual pro tective equipment must be used to prevent the shock and arc blast injury where hazardous live conductors are ex posed Do not hold the Current Probe anywhere beyond the tac tile indicator Before each use inspect the Current Probe Look for cracks or missing portions of the Current Probe housing or output cable insulation Also look for loose or wea kened components Pay particular attention to the insu lation surrounding the jaws Use caution when working with voltages above 60 Voc 30 Vac rms or 42 Vac peak Such voltages pose a shock hazard Use of this equipment is designed to protect against transients in equipment in fixed equipment installations such as distribution panels feeders and short branch circuits and lighting systems in large buildings Use of this equipment in a manner not specified herein may impair th
26. nt l installation et l utilisation de cette pince des tensions et des courants lev s risquent d tre pr sents dans le circuit test Ne pas utiliser l appareil s il est endommag Toujours brancher la sonde Uafficheur avant d installer les m choires autour du conducteur Toujours veiller retirer la sonde d un circuit lectrique sous tension et d brancher les cordons avant d enlever le couvercle du logement de la pile La sonde de courant ne doit tre utilis e qu en respectant ces consignes afin de pas entraver Les fonctions de s cu rit de la sonde Respecter les codes de s curit Locaux et nationaux Utili ser un quipement de protection individuel pour viter les blessures dues aux chocs lectriques et aux clairs d arc la o des conducteurs sous tension sont expos s Ne pas tenir la sonde de courant au del de l indicateur tactile Avant chaque utilisation examiner la sonde de courant Rechercher les fissures et les parties manquantes du boitier de la sonde de courant ou de l isolant du cable de sortie Rechercher galement les composants affaiblis ou desserres Faire particuli rement attention l isolant au tour des m choires Proc der avec prudence en travaillant avec des tensions sup rieures 60 V c c 30 V c a efficace ou 42 V c a maxi mum Ces tensions posent un risque d lectrocution Cet appareil est concu pour prot ger contre les tensions transitoires d
27. quel sont contr l s tous les modes de fonctionnement ainsi que le respect des caract ristiques techniques Les condition de garantie du produit d pendent du pays dans lequel vous l avez achet Pour toute r clamation veuillez vous adresser au fournisseur chez lequel vous vous tes pro cur le produit Pour un traitement plus rapide les clients de l union euro p enne UE peuvent faire effectuer les r parations directe ment par HAMEG M me une fois le d lai de garanti d pass le service client le de HAMEG se tient votre disposition Return Material Authorization RMA Avant chaque renvoi d un appareil veuillez r clamer un nu m ro RMA par Internet http www hameg com ou par fax Si vous ne disposez pas d emballage appropri vous pouvez en commander un en contactant le service commercial de HAMEG tel 49 0 6182 800 500 E Mail service hameg com Sous r serve de modifications Caract ristiques g n rales Caract ristiques lectriques Toutes les pr cisions sont tablies a 23 C 1 C Gamme de courant Gamme de mesure Capacit de surcharge Sensibilit en sortie Precision a 25 C R solution Niveau de bruit typique en sortie Imp dance de charge Sensibilit de position du conducteur Gamme de fr quence di dt suivant Temps de r ponse Coefficient de temp rature Humidit de fonctionnement Altitude Alimentation Tension utile voir Normes de s curit Dur e de
28. s Pour r gler la tension de sortie sur z ro enfoncez la molette et r glez la Pendant le r glage assu rez vous que la sonde est loign e du conducteur transpor tant le courant Mesure de courant 1 Activez la sonde en utilisant l interrupteur marche arr t et v rifiez que le voyant est allum 2 Branchez le cordon de sortie a un oscilloscope multimet re ou un autre appareil de mesure 3 Le cas ch ant r glez la tension de sortie de la sonde sur z ro conform ment a la section R glage du z ro Sous r serve de modifications Fixez la m choire de la sonde autour du conducteur en assurant un bon contact entre les faces de fermeture des m choires Observez et effectuez les mesures comme il y a lieu Une sortie positive indique que le courant circule dans la di rection affich e par la fleche sur la sonde Remplacement de la pile Avertissement Pour viter toute blessure toujours retirer la son de d un circuit lectrique sous tension et d bran cher les cordons avant d enlever le couvercle de la pile Ne jamais utiliser la sonde si le couvercle de pile n est pas en place Le t moin rouge clignote l approche de la tension d utilisation minimale Reportez vous figure 1 Appliquez la proc dure suivante 1 D tachez la sonde du conducteur mettez la hors tension l aide de l interrupteur marche arr t et d branchez les cordons de sortie au niveau de l quipement externe Desserrez la
29. stellung Uber Daumenrad 0 bis 50 C 20 bis 85 C Batterie entfernt 2909 Anderungen vorbehalten Bedienung und Handhabung de LED Nullung Batterie fachabdeckung EIN AUS Schalter Schutz Backen Batteriefachabdec kungsschraube unverlierbar 09906000 Bild 1 HZ56 2 Warnung MA Zur Vermeidung von Verletzung bei Gebrauch der Stromzange sicherstellen dass sich die Finger stets hinter dem Schutz befinden siehe Bild 1 Die Stromzange nicht verwenden wenn Teile davon einschlie lich Messleitung und Anschl s sen besch digt scheinen oder eine St rung des Messger ts vermutet wird Das Geh use periodisch mit einem feuchten Tuch und Reini gungsmittel abwischen Keine Scheuer oder L sungsmittel verwenden Die Sonde nicht in Fl ssigkeiten eintauchen Einschalten Wenn die Sonde eingeschaltet ist leuchtet die rote LED auf Die LED beginnt zu blinken wenn die Batteriespannung f r Normalbetrieb zu niedrig ist und macht den Bediener darauf aufmerksam dass die Batterie gewechselt werden muss Das Verfahren ist unten beschrieben Nullung Die Ausgangsnullungsoffsetspannung der Sonde kann auf grund von W rmeschwankungen und anderer Umgebungs bedingungen ndern Um die Ausgangsspannung auf Null nderungen vorbehalten Typische Leistungskurven Typischer Frequenzgang Frequenz in Hz 10 1000 100000 YE E LIN LIN IN 0
30. t te in jedem Fall per Internet http www hameg com oder Fax eine RMA Nummer an Sollte Ihnen keine geeignete Verpackung zur Verf gung stehen so k nnen Sie einen leeren Originalkarton ber den HAMEG Service Tel 49 0 6182 800 500 E Mail service hameg com bestellen 6 Anderungen vorbehalten Technische Daten Elektrische Eigenschaften Alle Angaben gelten bei 23 C 1 C Strombereich Messbereich Uberlastbarkeit Ausgangsempfindlichkeit Genauigkeit bei 25 C Auflosung Typischer Ausgangsger uschpegel Lastimpedanz 20 Aac eff oder DC 30A 500A 100 mV A 1 des Messwerts 2 mA 1 mA 200 uV rms gt 100k0 lt 100 pF Leiterpositionsempfindlichkeit 1 relativ zu Mittenmessung Frequenzbereich di dt folgend Ansprechzeit Temperaturkoeffizient Betriebsfeuchtigkeit H henlage Stromversorgung Arbeitsspannung siehe Sicherheitsstandards Batterielebensdauer Allgemeine Eigenschaften Maximaler Leitungsdurchmesser Ausgangskabel und Anschl sse Ausgangsnullung Betriebstemperaturbereich Lagertemperaturbereich Gewicht DC bis 100 kHz 0 5 dB 20A us besser als 1 us 0 01 des Messwerts C 15 bis 85 nicht kondensierend 2000 m 9 V Alkalibatterie NEDA 1604 PP3 IEC 6LR61 300 Vac eff oder DC 30 Stunden Anzeige f r schwache Batterie 19 mm Durchmesser 2 m Kable abgeschlossen mit BNC Anschluss 50 Ohm geliefert mit einem 4mm Doppelbananenstecker Manuelle Ein
31. t metro u otro equipo de medici n 3 Si fuera necesario ajuste el voltaje de salida de la sonda a cero tal como se describe en la secci n Ajuste del cero Reservado el derecho de modificaci n 4 Fije la mordaza de la sonda alrededor del conductor ase gurando un buen contacto entre ambas superficies de cierre de la mordaza 5 Observe y tome las mediciones de la manera requerida Una salida positiva indica que el flujo de la corriente es en la direcci n mostrada por la flecha de la sonda Reemplazo de la bater a Advertencia Para evitar lesiones personales siempre aseg rese de que antes de extraer la cubierta de la bater a la sonda sea retirada y los cables sean desconectados de todo circuito el ctrico energi zado Nunca opere la sonda sin la cubierta de la bater a colocada en su lugar Cuando se est por alcanzar el m nimo voltaje de operaci n el LED rojo destellar Consulte la Fig 1 Utilice el siguiente procedimiento 1 Libere la sonda del conductor ap guela con el interruptor de Encendido Apagado y desconecte los cables de salida del equipo externo 2 Afloje el tornillo cautivo que fija la cubierta de la bater a Alce la cubierta a 30 y tire de la misma hasta que salga del cuerpo de la sonda tal como se muestra en la Fig 1 En ese momento se podr acceder a la bater a Reemplace la bater a vuelva a colocar la cubierta de la bater a y apriete el tornillo Nota La colocaci n de un