Home

fan/light combination ventilators read and save these instructions

image

Contents

1. Or insert a straight blade screwdriver into slot in housing next to tab and twist screwdriver Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER WARRANTY BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will atits option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S
2. hidden utilities Ducted fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter pro tected branch circuit Never place a switch where it can be reached from a tub or shower This unit must be grounded a A For general ventilating use only Do not use to exhaust hazardous or explosive materi als and vapors This product is designed for ceiling installa tion only This product is designed for instal lation in ceilings up to a 12 12 pitch Ductwork must point up DO NOT MOUNT THIS PRODUCT IN A WALL To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Please read specification label on product for further information and requirements Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELS 678 678MX 679 680 679FL 680FL TYPICAL INSTALLATIONS POWER CABLE MOUNTING TABS CEILING l MATERIAL GRILLE HOUSING MOUNTED DIRECTLY TO JOIST 2x6 or larger Discharge parallel to joists POWER CABLE MOUNTING S ADDITIONAL CEILING MATERIAL GRILLE HOUSING MOUNTED TO 2x4 TRUSS Requires additional framing for mounting tabs Discharge parallel to joists ADDITIONAL FRAMING POWER CABLE
3. the top hole of each mounting tab Existing Construction 1 Choose the location for your fan light in the ceiling For best possible performance use the shortest possible duct run and a minimum number of elbows 2 In attic position mounting brackets against joist Trace outline of housing on ceiling material 3 Set housing aside and cut ceiling opening slightly larger than marked Broan at bathroomsource com is a division of kitchen accessories U N amp LM tf T E B bathroomsource com Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com Pa o o BROAN MODELS 678 678MX 679 680 679FL 680FL INSTALL THE HOUSING continued Existing Construction 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket 5 Additional mounting holes are provided for installations where access from above is inconvenient or not possible Nail or screw housing directly to joists or framing INSTALL THE DUCTWORK FLUSH NOTE The duct connector has a counter balanced damper flap The flap will be open approx 1 when duct connector is attached to hous ing This design permits insulation to be in direct contact with fan light housing per UL Underwriters Laboratories stan dards
4. 680FL 2 req 99150582 Grille Screw 97015163 Blower Assembly 678 97016207 Blower Assembly 678MX 97015165 Blower Assembly 679 679FL 97015157 Blower Assembly 680 680FL Blower Assemblies include Motor Impeller 8 14 amp 15 99270982 Receptacle Black 99270981 Receptacle White 98009612 Wire Panel 97015171 Wire Panel Assembly includes Key Nos 16 17 18 97014922 Housing 97014185 Damper Duct Connector 98008868 Wiring Plate 99150575 Screw 8 18 x 375 99150471 Ground Screw Not shown assembled Order replacement parts by PART NO not by KEY NO 97015202 98006276 97015167 97015969 Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELS 678 678MX 679 680 679FL 680FL Page 4 USE AND CARE CLEANING TO CLEAN LENS AND GRILLE Remove light lens and bulb Remove nut in center of reflector and lower assembly CAUTION Grille and reflector are separate units Unplug light from WHITE receptacle Plastic parts can be cleaned with mild soapy water use a mild detergent such as dishwashing liquid and dried with a soft cloth Do not use abrasive cloth steel wool pads or scouring powders TO CLEAN FAN ASSEMBLY Unplug fan assembly BLACK receptacle To remove motor plate Find the single tab on the motor plate located next to the recep tacles Push up near motor plate tab while pushing out on side of housing
5. CABLE DE ALIMENTACI N CONDUCTO __ CABLE REDONDO DES DE ALIMENTACI N 4 10 2 CM ALETAS DE MONTAJE CUBIERTA Mia DEL TECHO REJILLA ERAS a VIGUETA CUBIERTA MONTADA DELTECHO REJILLA DEL TECHO DIRECTAMENTE EN LA VIGUETA CUBIERTA MONTADA EN UNA 2x6 o m s grande ESTRUCTURA ADICIONAL Descarga paralela a las viguetas Descarga a 90 de las viguetas REDONDO dd Y ess a aumentacion E0020 7 VIGUETAO _ 4 VIGUETA O Se Sa an Doe or VIGADE 4 VIGA DE A GM 2x4 DE CUBIERTA MATERIAL gt DE CIELO RASO RENA PURAS A ESTRUCTURA VIGUETA O VIGA DE MATERIAL ADICIONAL VIGA DE CUBIERTA MONTADA 2x4DE PECIELORASO REJILLA 2x4 DE CIELO EN UNA VIGA DE 2x4 Raso CUBIERTA MONTADA RASO Se requiere una estructura adicional para las aletas de montaje Descarga paralela a EN UNA VIGA DE 2x4 Se requiere una estructura adicional para las aletas de montaje Descarga a las viguetas 90 de las viguetas ESTRUCTURA c CONDUCTO ABLE DE REDONDO DE CABLE DE de ea ADICIONAL ALIMENTACI N op E ALETAS DE ALETAS DE MONTAJE VIGUETA MATERIAL VIGUETA ESTRUCTURA DE CIELO RASO REJILLA VIGUETAN MATERIAL ADICIONAL VIGUETA CUBIERTA MONTADA I DE CIELO RASO REJILLA EN UNA VIGUETA I Se requiere una estructura adicional para las aletas de montaje Descarga paralela a las viguetas CUBIERTA MONTADA EN UNA VIGUETA 1 Se requiere una estruc
6. ERRA desnudo CONTROL DOBLE se vende por separado CAJA DEL CONMUTADOR erg VENT PLACA DE CONEXIONES L NEA DE ENTRADA DE 120 VCA 1 Conecte la unidad de acuerdo con este diagrama Extienda el cable el ctrico a la unidad tan directamente como sea posible No permita que el cable toque los costados ni la parte superior de la unidad despu s de que la instalaci n est terminada CONEXI N DE LA REJILLA 1 Deslice el reflector de la l mpara enfrente de la abertura para la rejilla Enchufe la l mpara en el recept culo BLANCO Coloque el conjunto rejilla reflector sobre el tornillo que sobresale y fijelo usando la tuerca de caperuza que se proporciona APRIETE CON LA MANO la tuerca de caperuza 1 4 de vuelta despu s de que est ajustada 2 Instale el foco de la l mpara no incluido Vea la paginaci n siguiente para el tipo y la talla para su modelo Introduzca una de las aletas del lente de la l mpara en la ranura del conjunto rejilla reflector Comprima ligeramente la otra aleta y con ctela a presi n en la otra ranura Broan at bathroomsource com is a division of kitchen accessories VUO N L 1 M4 T amp BB bathroomsource com PD qQE 2 BROAN INSTRUCCIONES DE OPERACI N Y LIMPIEZA ADVERTENCIA ANTES DE LIMPIAR O DAR SERVICIO ESTA UNIDAD DESCONECTE EL SUMINISTRO DE ENERG A Y BLO QUEE EL PANEL DE SERVICIO REEMPLAZO DEL FOCO Quite el lente comprimiendo ligeramente los lado
7. F YOU HAVE A TRUSS OR I JOIST INSTALLATION MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANNER Additional framing must be a 2x6 minimum height at least 9 inches long New Construction 1 Choose the location for your fan in the ceiling For best possible performance use the shortest possible duct run and a minimum number of elbows BOTTOM EDGE OF JOIST 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1 amp 1 1 4 thick ceiling material Holes in corners of housing are labeled with various ceiling material thicknesses Position housing so bottom edge of joist is visible through a matched set of holes The housing is now in the proper position for that ceiling material thickness Additional positioning feature for 1 2 thick ceiling material Bend two tabs on side of housing 90 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting brackets Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELS 678 678MX 679 680 679FL 680FL Page 2 INSTALL THE HOUSING continued New Construction 3 Set housing aside and drive nails partially into joist at the top of both keyhole marks z 4 Hang housing from nails and pound nails tight To ensure a noise free mount pound another nail through
8. MOUNTING pr JOIST l CEILING MATERIAL po JOIST GRILLE FRAMING 4 ROUND POWER CABLE DUCT N MOUNTING TABS ADDITIONAL CEILING FRAMING MATERIAL CEILING GRILLE JOIST HOUSING MOUNTED TO ADDITIONAL FRAMING Discharge 90 to joists 4 ROUND POWER CABLE ADDITIONAL 2x4 NE 4 CEILING ERAS GRILLE FRAMING 3 CEILING JOIST or JOIST or TRUSS TRUSS HOUSING MOUNTED TO 2x4 TRUSS Requires additional framing for mounting tabs Discharge 90 to joists 4 ROUND POWER CABLE DUCT N MOUNTING TABS ADDITIONAL Ir IST CEILING GRILLE FRAMING JOIS g JOIST MATERIAL HOUSING MOUNTED TO I JOIST HOUSING MOUNTED TO I JOIST Requires additional framing for mounting tabs Discharge parallel to joists Requires additional framing for mounting tabs Discharge 90 to joists Additional framing must be a 2x6 minimum height at least 9 inches long Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 Broan at bathroomsource com is a division of kitchen accessories U Nk MM 6 TEB bathroomsource com anon BROAN TYPICAL INSTALLATIONS continued 4 ROUND DUCT SUSPENDED CEILING MATERIAL GRILLE SUSPENDED CEILINGS Housing hung with wires 3 point mount INSTALL THE HOUSING PLEASE NOTE THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6 JOISTS I
9. O Para quitar la placa del motor Localice la aleta de la placa del motor se encuentra junto a los recept culos Empuje hacia arriba la aleta de la placa del motor mientras empuja hacia afuera el costado de la cubierta O bien introduzca un destornillador de punta recta en la ranura de la cubierta junto a la aleta y haga girar el destornilla dor Con una aspiradora limpie suavemente el ventilador e motor y el interior de la cubierta NUNCA DEBE SUMERGIR EN AGUA P gina 8 LAS PIEZAS METALICAS NI LAS ELECTRICAS PIEZAS DE SERVICIO Ne CLAVE EN DESCRIPCI N 97013578 Lente de la l mpara 97005316 Tuerca de caperuza 99770029 Portabulbo 678 678MX 679 680 97014211 Reflector de la l mpara 678 678MX 679 68 97014212 Conjunto del reflector de la l mpara 678 678MX 679 680 incluye Clave No 3 y 4 Cableado de la agarradera de la l mpara 679FL Reflector de la l mpara 679FL Conjunto del reflector de la l mpara 679FL incluye Clave No 5 y 6 Conjunto del reflector de la l mpara 680FL 97013974 Rejilla 97014926 Placa del motor 99080521 Motor 678 99080546 Motor 678MX 99080522 Motor 679 679FL 99080517 Motor 680 680FL 99111002 Pist n impulsor 678 678MX 99110446 Pist n impulsor 679 679FL 99020276 Pist n impulsor 680 680FL 99260428 Tuerca del motor 678 679 679FL se req 2 Tuerca del motor 680 680FL se req 2 Tornillo de la rej
10. OP TION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUEN TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defectin the product or part Atthe time of requesting warranty service you must present evidence of the original purchase date 99042900G Broan at bathroomsource com is a division of kitchen accessories U N dk MM 1 TT EB bathroomsource com PA ees BROAN VENTILADORES CON L MPARA Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELOS 678 678MX 679 680 679FL 680FL LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA dl A PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES PERSONALES OBSERVE LO SIGUIENTE 1 Utilice esta unidad solamente de acuerdo con las instrucciones del fabricante Si tiene preguntas comun quese con el fa
11. PA ees BROAN bathroomsource com FAN LIGHT COMBINATION VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OB SERVE THE FOLLOWING 1 N 0 8 9 Use this unit only in the manner intended by the manufacturer If you have questions con tact the manufacturer at the address or tele phone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock the ser vice disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warn ing device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accor dance with all applicable codes and stan dards including fire rated construction codes and standards Sufficient air is needed for proper combus tion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heat ing Refrigeration and Air Conditioning En gineers ASHRAE and the local code au thorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other
12. The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 1 Snap the damper duct connector onto housing Make sure that tabs on the connector lock into slots in housing Top of damper duct connector should be flush with top of hous ing 2 Connect 4 round duct to damper duct connector and ex tend duct to outside through a roof or wall cap Check damper to make sure that it opens freely Tape all duct connections to make them secure and air tight Page 3 CONNECT THE WIRING SCHEMATIC WIRING DIAGRAM WHITE RECEPTACLE LIGHT BLACK RECEPTACLE FAN WIRING PLATE 120 VAC LINE IN 1 Wire unit following diagram above Run electrical cable as direct as possible to unit Do not allow cable to touch sides or top of unit after installation is complete ATTACH THE GRILLE 1 Slide light reflector into front of grille opening Plug light into WHITE receptacle Place grille reflector combina tion over protruding screw and fasten in place using acorn nut provided HAND TIGHTEN acorn nut 1 4 turn after it is snug 2 Install light bulb not included See next page for type and size for your model Insert one tab on light lens into a slot in the grille reflector combination Squeeze other tab slightly and snap into remaining slot Broan at bathroomsource com is a division of kitchen accessories U N dk ML Ml T E 1D bathro
13. bricante a la direcci n o al n mero telef nico que se indica en la garant a 2 Antes de dar servicio o limpiar la unidad interrumpa el uministro de energ a en el panel de servicio y bloquee los ispositivos de desconexi n para evitar la reinstalaci n acci ental de la energ a Cuando no se puedan bloquear los ispositivos de desconexi n fije seguramente en el panel de ervicio un medio de advertencia que sea visible como por jemplo una etiqueta 3 Una persona o personas calificadas deben realizar el trabajo de instalaci n y el cableado el ctrico de acuerdo con todos los c digos y normas aplicables inclusive los c digos y normas de construcci n para evitar incendios 4 Senecesita suficiente aire para que se realice la combusti n y ladescarga de gases adecuadas atrav s de la chimenea del equipo para quemar combustible a fin de evitar las corrientes de inversi n Observe los lineamientos del fabricante del equipo de calefacci n y las normas de seguridad como por ejemplo las publicadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA y la Sociedad Americana de Ingenieros en Calefacci n Refrigeraci n y Sistemas de Acondicionamiento deAire Ameri can Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y los c digos locales ditioning Engineers ASHRAE and the local code authorities 5 Cuando corte o perfore la pared o el cielo raso tenga cuidad
14. ezas que hayan sido utilizadas de forma err nea negligente que hayan causado un accidente o que hayan sido reparadas o mantenidas inapropiadamente por otras compa as que no sean Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitaci n antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE BROAN NUTONE DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTAGARANTIA BROAN NUTONE NO SERA RESPONSABLE POR DA OS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar en la garant a de servicio usted debe a notificar a Broan NuTone al domicilio o al n mero de tel fono que se menciona abajo b dar el n mero del modelo y la identif
15. icaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra 99260425 99150582 97015163 97016207 97015165 97015157 99270982 99270981 98009612 97015171 97014922 97014185 98008868 99042900G Broan at bathroomsource com is a division of kitchen accessories U N dk MM oI or EB
16. illa Conjunto del ventilador 678 Conjunto del ventilador 678MX Conjunto del ventilador 679 679FL Conjunto del ventilador 680 680FL Conjuntos del ventiladores incluyes Motor Pist n impulsor 8 14 amp 15 Recept culo negro Recept culo blanco Panel del cableado Conjunto del panel de cableado incluye Clave No 16 17 18 Cubierta Conector del regulador de tiro conducto Placa de conexiones 99150575 Tornillo 48 18 x 375 99150471 Tornillo de conexi n a tierra No ilustrado ensamblado Pida piezas de servicio dando como referencia el N DE PIEZA no el Ne DE CLAVE 97015202 98006276 97015167 97015969 GARANTIA BROAN NUTONE LIMITADA POR UN A O Broan NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio Broan NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o pi
17. leta estar abierta aproximadamente 1 2 5 cm cuando el conector del conducto se sujete a la cubierta Este dise o permite que el material de aislamiento est en contacto directo con la cubierta del ventilador con l mpara de acuerdo con las normas de UL Underwriters Laboratories Sin embargo la m s ligera corriente invertida cerrar la aleta del regulador de tiro evitando as la entra da de aire a la unidad o al espacio terminado 1 Conecte a presi n el conector del regulador de tiro conducto en la cubierta Aseg rese de que las aletas del conector queden fijas en las ranuras de la cubierta La parte superior del conector del regulador de tiro conducto debe quedar al ras de la parte superior de la cubierta 2 Conecte el conducto redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a trav s de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que abre libremente Coloque cinta en todas las conexiones de los conductos para asegurarlas y hacerlas herm ticas Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELOS 678 678MX 679 680 679FL 680FL P gina 7 CONEXI N EL CTRICA DIAGRAMA EL CTRICO ENE BLANCO TIERRA TIERRA a CAJA DE CONMUTADOR UNIDAD NEGRO BLANCO sa AZUL RECEPT CULO BLANCO LAMP RECEPT CULO NEGRO VENT corr ROJO TI
18. ma nera que el borde inferior de la cubierta quede al ras del cielo raso terminado Caracter stica adicional para la colocaci n en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 4 3 2 cm Los orificios que se encuentran en las esquinas de la cubierta est n marcados con varios espesores del material del cielo raso Coloque la cubierta de manera que el borde inferior de la vigueta sea visible a trav s del conjunto de orificios que coinciden Ahora la cubierta se encuentra en la posici n adecuada para ese espesor del material del cielo raso Caracter stica adicional para la colocaci n en material de cielo raso de 12 1 3 cm Doble a 90 y hacia afuera las dos aletas que se encuentran a los costados de la cubierta Levante la cubierta hasta que las aletas entren en contacto con la cara inferior de la vigueta Marque el orificio con forma de cerradura de ambas abrazaderas de montaje Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELOS 678 678MX 679 680 679FL 680FL P gina 6 INSTALACION DE LA CUBIERTA continuaci n Construcci n nueva 3 Coloque la cubierta a un lado e introduzca parcialmente los cla vos en la vigueta en la parte superior de ambas marcas de los orificios en forma de cerradura z 4 Suspenda la cubierta con los clavos e introduzca los clavos com pletamente Para asegurar un montaje sin ruido coloque otro clavo en el orificio supe
19. o de no da ar el cableado el ctrico ni otras conexiones de servicios que se encuentren ocultas 6 Los ventiladores con conductos siempre deben tener salida hacia el exterior 7 Sisevaainstalar esta unidad sobre una tina o ducha debe marcarse que es apropiada para esta aplicaci n y conectarse aun GFCI interruptor accionado por p rdida de conexi n a tierra en un circuito de derivaci n protegido 8 Nunca coloque el interruptor en un lugar en donde se pueda alcanzar desde la tina o ducha 9 Modelos fluorescentes solamente No emplee un interrupto reductor para controlar la luz de esta unidad 10 Esta unidad debe conectarse atierra PRECAUCI N A Esta unidad debe usarse solamente para ventilaci n gen eral No la utilice para la descarga de materiales ni vapores peligrosos o explosivos 2 Este producto est dise ado solamente para instalarse en el cielo raso Este producto est dise ado para instalarse en cielos rasos con una pendiente de hasta 12 12 El sistema de conductos debe apuntar hacia arriba NO MONTE ESTE PRODUCTO EN LAPARED 3 Para evitar causar da o a los cojinetes del motor y pistones impulsores ruidosos y o no balanceados mantenga los aerosoles para pirca el polvo de construcci n etc lejos del motor 4 Por favor consulte la informaci n y los requerimientos adicionales contenidos en la etiqueta de especificaciones que se encuentra en el producto nanan Do INSTALACIONES T PICAS
20. omsource com A eee BROAN USE AND CARE WARNING DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVIC ING THIS UNIT BULB REPLACEMENT Remove lens by gently depressing sides and pull down Models 678 678MX 679 amp 680 Use 100 Watt maximum incandescent bulb Model 679FL Use only the following 13 Watt fluorescent lamps Broan97010729 Sylvania CF13DD827 Phillips PL C 13W 27 USA General Elec tric F13DBX23T4 SPX27 Osram CF13DD827 NEMA Type CFQ13W GX23 Model 680FL Use only the following 22 Watt fluorescent lamps Broan97015191 Phillips PL C 15MM 22W Panasonic FDL22 NEMA Type CFQ20W GX32d MOTOR LUBRICATION The motor is permanently lubricated Do not oil or disassemble motor SERVICE PARTS 97013578 Light Lens 97005316 Acorn Nut 99770029 Bulb Holder 678 678MX 679 680 97014211 Light Reflector 678 678MX 679 680 97014212 Light Reflector Assembly 678 678MX 679 680 includes Key Nos 3 amp 4 amp Holder Wiring 679FL ight Reflector 679FL ight Reflector Assembly 679FL incl Key Nos 5 amp 6 ight Reflector Assembly 680FL 97013974 Grille 97014926 Motor Plate 99080521 otor 678 99080546 otor 678MX 99080522 otor 679 679FL 99080517 otor 680 680FL 99111002 Impeller 678 678MX 99110446 Impeller 679 679FL 99020276 Impeller 680 680FL 99260428 Motor Nut 678 678MX 679 679FL 2 req 99260425 otor Nut 680
21. rior de cada aleta de montaje Construcci n existente 1 Seleccione la ubicaci n del ventilador con l mpara en el cielo raso Para obtener el mejor rendimiento posible utilice un tramo de conductos lo m s corto posible y un n mero m nimo de codos 2 En el entretecho coloque las abrazaderas de montaje contra la vigueta Trace el per metro de la cubierta en el material del techo 3 Coloque la cubierta a un lado y haga una abertura en el techo ligeramente m s grande que el per metro marcado Broan at bathroomsource com is a division of kitchen accessories U N dk Mo M 1 TT EB bathroomsource com PA ees BROAN INSTALACI N DE LA CUBIERTA continuaci n Construcci n existente 4 Coloque la cubierta en la abertura de manera que su borde infe rior quede al ras del cielo raso terminado Clave la cubierta en la vigueta a trav s del orificio en forma de cerradura en ambos lados Para asegurar un montaje sin ruido coloque otro clavo en el orificio superior de cada aleta de montaje ORIFICIOS DE MONTAJE o ADICIONALES O 5 En la cubierta se pueden encontrar orificios de montaje adicio nales para aquellas instalaciones en las que es inconveniente o imposible el acceso desde arriba Clave o atornille la cubierta directamente en las viguetas o el armaz n INSTALACI N DEL SISTEMA DE CONDUCTOS NOTA El conector del conducto tiene una aleta compensadora para el regulador de tiro La a
22. s y hal ndolas hacia abajo Modelos 678 678MX 679 amp 680 Utilice un foco incandescente de 100 wats como m ximo Modelo 679FL Utilice solamente las l mparas fluorescentes siguientes de 13 vatios Broan 97010729 Sylvania CF13DD827 Phillips PL C 13W 27 USA General Electric F13DBX23T4 SPX27 Osram CF13DD827 NEMA Type CFQ13W GX23 Modelo 680FL Utilice solamente las l mparas fluorescentes siguientes de 22 vatios Broan 97015191 Phillips PL C 15MM 22W Panasonic FDL22 NEMA Type CFQ20W GX32d LUBRICACI N DEL MOTOR El motor est permanentemente lubricado No lubrique ni des monte el motor Call 1 800 667 8721 anywhere in the US and Canada www bathroomsource com MODELOS 678 678MX 679 680 679FL 680FL A EEE INSTRUCCIONES DE OPERACION Y LIMPIEZA LIMPIEZA PARA LIMPIAR EL LENTE Y LA REJILLA Quite el lente de la l mpara y el foco Quite la tuerca que se en cuentra en el centro del reflector y baje el conjunto PRECAUCI N La rejilla y el reflector son unidades separadas Desenchufe la l mpara del recept culo BLANCO Las piezas de pl stico se pueden limpiar con una soluci n suave de agua y jab n use un detergente suave como por ejemplo l quido para lavar vajilla y s quelas con un pa o suave No use tela abrasiva almo hadillas de estropajo de acero ni polvos desengrasadores PARA LIMPIAR EL CONJUNTO DEL VENTILADOR Desenchufe el conjunto del ventilador recept culo NEGR
23. tura adicional para las aletas de montaje Descarga a 90 de las viguetas La estructura adicional debe ser un tramo de 2x6 altura m nima de al menos 9 pulgadas 23 cm de largo A la persona que realiza la instalaci n Deje este manual con el due o de la casa Al due o de la casa Las instrucciones de operaci n y limpieza se encuentran en la p gina 8 Broan at bathroomsource com is a division of kitchen accessories uU N ELMI TEB bathroomsource com anon BROAN INSTALACIONES TIPICAS continuacion CONDUCTO REDONDO DE 4 10 2 CM J CABLE _ DE ALIMENTACION ALETA DE MONTAJE CUBIERTA MATERIAL DEL TECHO SUSPENDIDO REJILLA TECHOS SUSPENDIDOS Cubierta montada con cables Montaje de tres puntos INSTALACI N DE LA CUBIERTA POR FAVOR NOTE LAS SIGUIENTES ILUSTRACIONES DE LA INSTALACI N MUESTRAN VIGUETAS DE 2 X 6 SI LA INSTALACI N ES EN UNA VIGA O EN UNA VIGUETA EN Il MONTE EL VENTILADOR EN LA ESTRUCTURA ADICIONAL DE LA MISMA MANERA La estructura adicional debe ser un tramo de 2x6 altura m nima de al menos 9 pulgadas 23 cm de largo Construcci n nueva 1 Seleccione la ubicaci n del ventilador con l mpara en el cielo raso Para obtener el mejor rendimiento posible utilice un tramo de conductos lo m s corto posible y un n mero m nimo de codos BORDE INFERIOR DE LA VIGUETA 2 Coloque las abrazaderas de montaje contra la vigueta de