1. BLACK BOX Copyright 2002 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 BL ACK BOX E RM360A R4 RM361A R4 RM364A R4 RM365A R4 Desktop Serv Rack w Sliding Keyboard Shelf amp Tray Tower Serv Rack w Sliding Keyboard Shelf amp Tray CUSTOMER Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 SUPPORT FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 INFORMA TION Web site www blackbox com E mail info blackbox com FCC IC RFI STATEMENTS TRADEMARKS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be requi
2. lavabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de Operaci n o como se indique en el aparato 12 Precauci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los c
3. the problem We will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse and the results of any testing you ve already done 4 2 Shipping and Packaging If you need to transport or ship your Serv Rack Package it carefully We recommend that you use the original container Before you ship the unit back to Black Box for repair or return contact us to get a Return Authorization RA number
4. 00 Figure 3 1 Attaching the base angles CHAPTER 3 Installation 3 2 Part 2 Attaching the Monitor Shelf 1 Stand the Serv Rack upright 2 Align the holes in the monitor shelf with the corresponding holes in the vertical upright channels as shown in Figure 3 2 3 If you re going to install the shelf at the top of the Rack as shown in Figure 3 2 install four of the included hex head bolts and lock washers then install four of the included panhead screws tightening everything by hand only 4 If you re going to install the monitor shelf in the Rack but not at the top use eight panhead screws only Figure 3 2 Attaching the monitor shelf at the top of the Serv Rack DESKTOP AND TOWER SERV RACKS 3 3 Part 3 Doing the Final Tightening 1 Make sure the rack is square by using a level or a carpenter s square as shown in Figure 3 3 2 Tighten all bolts using a socket or wrench 20000000000000000000000000000000000000000000000000000000000000000000 Li il ul Figure 3 3 Tightening the bolts 3 4 Part 4 Securing the Serv Rack 1 If your Serv Rack is going to be installed in a permanent location we recommend bolting it to the floor or to an equally stabilizing and secure surface using the 4 holes in each of the corners of the base 2 If the Serv Rack needs to be mobile order casters four per set part number RM369 R2 Mount them using the holes in each of the corners of the base CH
5. 360A R4 and RM361A R4 64 10 32 x 4 panhead screws RM364A R4 and RM365A R4 48 10 32 x panhead screws Item 8 Item 9 1 Sliding keyboard shelf with mouse tray 2 Tie down brackets for tower CPUs 8 tie down straps for desktop CPUs Item 10 North America only 1 6 outlet power strip with 6 foot 1 8 m power cord mounted on an adapter bracket 2 4 Before You Begin Assembling the Serv Rack You will need the following tools in order to assemble the Serv Rack e 4 socket or wrench A Phillips screwdriver e A level or a carpenter s square CHAPTER 2 Introduction Switch compartment 4 4 H x 17 75 W x 10 D 11 2 x 45 1 x 25 4 cm asters are available separately as product ode RM369 R2 Figure 2 1 Construction of the Serv Rack DESKTOP AND TOWER SERV RACKS 3 Installation 3 1 Part 1 Attaching the Base Angles to the Vertical Upright Channels 1 Lay the vertical upright channels on their sides Align the holes in the base with the corresponding holes in each upright channel see the illustration below The long leg of the base should be facing you Be sure that the open sides of the upright channels face each other Install four hex head bolts and lock washers Tighten the bolts by hand only at this point Turn the vertical upright assembly over rotate 180 and repeat steps 1 and 2 Tighten by hand only dioooooooooo OOOO0O0O000000000000000000000000000
6. APTER 3 Installation 3 5 Part 5 Installing the CPU Shelves CPU shelves are packed in pairs and are designed to be used with either Desktop or Tower Serv Racks The shelves should be mounted back to back They can also be mounted as single shelves in any EIA spacing 1 Attach the shelf to the vertical channels by inserting four of the included panhead screws through the mounting flanges in front of the shelf and tapped holes in the vertical channels as shown in Figure 3 4 2 Tighten the screws to secure the shelves Figure 3 4 Attaching the Shelves DESKTOP AND TOWER SERV RACKS 3 6 Part 6 Attaching the Tie Down Brackets 3 6 1 DESKTOP SERV RACK RM360A R4 AND RM361A R4 1 Place the CPU in the position you want it on the shelf 2 Position the tie down bracket above the CPU with the padded side facing the CPU as shown in Figure 3 5 3 Insert four of the included panhead screws through the mounting holes in the rack 4 Tighten the screws with a Phillips screwdriver Figure 3 5 Attaching tie down brackets to a Desktop Serv Rack CHAPTER 3 Installation 3 6 2 TOWER SERV RACK RM364A R4 AND RM365A R4 1 2 Loosen the wing nuts located on both sides of the bracket Fully extend each bracket s side member Loosen the flange nuts located at the rear of the bracket Ful
7. a 6 outlet surge protected power strip with a 6 foot 1 8 m power cord The power strip is only included in North America The 23 58 4 cm rackmount width allows plenty of room for most standard computers file servers towers and monitors The shelves are designed so that the equipment can be operated from a standing position they can be positioned at a variety of heights for operator comfort The extra deep base assemblies provide superior stability without having to bolt the unit to the floor Casters are also available The Serv Racks are shipped knocked down and require assembly Additional features Aswitch compartment 2 or 4 port located under the monitor shelf A drawerlike sliding keyboard shelf with a mouse tray you can position as needed The heavy duty steel monitor shelf holds up to 75 Ib 34 kg The steel CPU shelves are adjustable and can hold up to 100 Ib 45 4 kg DESKTOP AND TOWER SERV RACKS 2 3 What s Included You should have received the following components with your Serv Rack Refer to Figure 2 1 on the next page as you identify where each part goes These numbers are also used in the illustrations in Chapter 3 ltem 1 Item 2 Item 3 Item 4 Item 5 ltem 6 Item 7 2 Vertical upright channels 2 Base angles 1 Monitor shelf with switch compartment 12 13 x 1 hex head bolts 12 lock washers CPU shelf packs 2 for Tower Serv Racks 4 for Desktop Serv Racks RM
8. els 8 3 2 Part 2 Attaching the Monitor Shell sscccnivinsin orleans toa ER Rico tete 9 3 3 Part3 Dome the Final Tightening rne etr ree Hi celos Fee Edere NER Eden Eds 10 5 4 Part 4 Securmg the Serv Rack ent dee ter ete e ERO Ee EET te e Re REN eed 10 3 5 Parto Installing the CPU Shelv s dotada 11 3 6 Part 6 Attaching the Tie Down Brackets wo ieee eese eene een nennen nennen 12 3 6 1 Desktop Serv Rack RM360A R4 and 361 4 12 3 6 2 Tower Serv Rack RM364A R4 and RM365A R4 oocccccccccccccccnononanananano nono nnonnnnnnnnnnnnnnonnninnos 13 3 7 Part 7 Installing the Keyboard Shelter ta 14 3 8 Part 8 Installing the Power Strip North America 15 A Iro bleshootng veritat uo un ee eeu 16 4 L Calling Black iaa ett re e 16 4 2 Shipping and Packaglng ierit HO RE RR RR SRI e NR HERR Oe te ORE guns 16 1 Specifications 1 1 Serv Racks RM36xA R4 Size 61 H x 23 W x 23 D 155 x 58 4 x 58 4 cm Weight 130 lb 59 1 kg 1 2 Power Strip Included North America Only Compliance UL CSA Input Rating and Cord 120 VAC 60 Hz 15 amps maximum through a 6 ft 1 8 m cord that exits the end of the enclosure and has a standard NEMA 5 15P plug Surge Protection Circuitry Single stage Response time Less than 5 nanoseconds UL 1449 clamping voltage and maximum surge resistance 400
9. ly extend the L shaped angle brackets to their maximum width Position the CPU towers where you want them on the shelf Attach the bracket assembly to the upright channels using eight of the included panhead screws Repeat for the other side of the rack Slide the horizontal member toward the rack until the angle brackets can be positioned at the sides of the towers Tighten the wing nuts and repeat for the other side of the rack Slide the angle brackets against the sides of the towers Tighten the flange nuts Repeat for the other side of the rack Angle Bracket Horizontal Header Side Header Figure 3 6 Attaching tie down brackets to a Tower Serv Rack DESKTOP AND TOWER SERV RACKS 3 7 Part 7 Installing the Keyboard Shelf 1 Select the desired mounting location for the keyboard shelf either the one included with the Serv Rack or the RM359 R2 if you ve ordered it separately Carefully position the shelf so that the mounting holes in the shelf s flanges align with the tapped holes in the vertical channels NOTE Tapped holes are spaced according to EIA standard universal hole spacing 2 Attach the keyboard shelf to the vertical channels by inserting four of the included panhead screws through the mounting flanges in front of the shelf and the tapped holes in the vertical channels 3 Tighten the screws securely 4 To use the shelf simply pull the tray toward you It will smoothly roll forward on a ball beari
10. ng slide 5 There are four mounting options for the keyboard shelf s mouse tray The tray will be positioned on the right when you receive the keyboard shelf as shown in Figure 3 7 If you d like to move it to one of the other positions unscrew the tray Reposition it and insert the screws you just removed in the pre drilled holes Tighten the screws until the tray is securely in place The mouse tray slides underneath the the keyboard shelf when not in use Make sure to push the tray into this storage position before closing the shelf If you are outside North America this completes your Serv Rack installation Figure 3 7 The keyboard shelf with mouse tray CHAPTER 3 Installation 3 8 Part 8 Installing the Power Strip North America Only 1 If you are in North America you should have received a power strip with your Serv Rack This strip has rackmount brackets attached to it at the factory Attach the bracketed power strip to the vertical channels by inserting four of the included panhead screws through the mounting flange in the bracket and the tapped holes in the vertical channels We recommend attaching the power strip in the rear of the Serv Rack toward the bottom 2 Tighten the screws This completes your Serv Rack installation 4 Troubleshooting 4 1 Calling Black Box If you have any problems with your Serv Rack contact Black Box Technical Support at 724 746 5500 Before you do make a record of the history of
11. ontactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparato ha sido tirado o su cubierta ha sido da ada Jh Contents Chapter Page Ss AA NARA 4 Ll Serv Racks RM906XxA R4 4 1 2 Power Strip Included North America Only ee een eene een rennen 4 2 M 5 2 L valable MOIS sica 5 22 DETO a rta a ses 5 2 3 Whats Included oco mie DU 6 2 4 Before You Begin Assembling the Serv Rack 6 D Installation escis he Fut Reese ISP 8 3 1 Part 1 Attaching the Base Angles to the Vertical Upright Chann
12. red to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le R glement sur le brouillage radio lectrique publi bar Industrie Canada TRADEMARKS USED IN THIS MANUAL UL is a registered trademark of Underwriters Laboratories Incorporated Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners o MA DESKTOP AND TOWER SERV RACKS INSTRUCCIONES DE SEGURIDAD Normas Oficiales Mexicanas Electrical Safety Statement 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o
13. volts computer grade Actual clamping voltage 350 volts Maximum surge current 13 000 amps EMI RFI noise reduction 40 dB Circuit Breaker 15 amps User Control 1 125 VAC 15 amp lighted rocker switch Enclosure Plastic mounts with 2 keyhole slots on rear Output Rating and Connectors 125 VAC at up to 15 amps on 6 equally spaced NEMA 5 15R outlets Size 1 6 H x 2 5 W x 13 25 D 4 1 x 6 4 x 33 7 cm Weight 1 7 Ib 0 8 kg 2 Introduction 2 1 Available Models Currently we offer four Desktop and Tower Serv Rack models Product Code Product Name RM360A R4 Beige Desktop Serv Rack with Sliding Keyboard Shelf and Tray RM361A R4 Black Desktop Serv Rack with Sliding Keyboard Shelf and Tray RM364A R4 Beige Tower Serv Rack with Sliding Keyboard Shelf and Tray RM365A R4 Black Tower Serv Rack with Sliding Keyboard Shelf and Tray We also offer these accessories Product Code Product Name RM357 Beige CPU Shelf for Desktop and Tower Serv Racks RM358 Black CPU Shelf for Desktop and Tower Serv Racks RM359 R2 Black Sliding Keyboard Shelf with Mouse Tray RM369 R2 Casters 2 2 Description The Desktop and Tower Serv Racks are designed to organize your computer hardware and eliminate clutter One Serv Rack will accommodate up to four desktop or tower CPUs These Serv Racks come fully equipped with heavy duty drilled and tapped steel upright channels heavy duty steel CPU shelves steel monitor shelf sliding keyboard shelf and