Home
ATTENTION ATENCIÓN ATTENTION
Contents
1. E 5 REMOTE CONTROL FUNCTIONS 4 BUTTONS REMOTE NOTE The unit Main Power Switch must be turn on in order for the Remote Control to function POWER The Power button will put the insert in a standby mode This will turn off all functions at once but will hold the settings in memory By pressing the button again the unit will turn on at the same settings FLAME Each time this button is pressed the intensity of the flame decreases There are six brightness levels you can cycle through including the OFF setting 2 HEAT This button will turn the power to the heater and blower on and off when the heater is turned ON it will take several seconds for the unit to begin blowing hot air The rotary switch Temperature controls the thermostat feature to help regulate your room s temperature accordingly bil PLAY i PAUSE Note Please operate remote transmitter at a slow measured a ae p pace Depress the remote control buttons with an even motion Note This button function just apply for ARU series and gentle pressure Repeatedly pressing buttons in rapid model succesion may cause the transmitter to malfunction Press this button you can control the undulating flame effect to play or pause Notice This remote control uses 2 PCS AAA batteries Never dispose ofbatteries in fire except under condition controlled incineration Failure to observe this precaution may resu
2. l 2 11 12 13 14 15 16 17 Lire toutes les instructions avant d utiliser l appareil Cet appareil est chaud pendant son utilisation Pour viter toute br lure la peau nue ne doit jamais toucher directement les surfaces chaudes Si elles sont fournies utiliser les poign es pour d placer cet appareil Garder les mati res inflammables comme les meubles coussins et oreillers articles de literie papiers v tements et rideaux a au moins 0 9 m 3 pi de l appareil AVERTISSEMENT Pour viter une surchauffe ne pas recouvrir l appareil de chauffage Ne pas utiliser dans une garde robe ATTENTION Lorsque l appareil de chauffage fonctionne sans surveillance une prudence extr me est requise si des enfants ou des personnes handicap es sont proximit Cet appareil ne doit pas tre utilis par des enfants des personnes capacit s physiques sensorielles ou mentales restreintes ou des personnes qui connaissent peu le produit ou qui ne sont pas famili res avec son utilisation moins qu ils soient supervis s ou qu on leur donne des instructions pr cises Les enfants ne doivent pas jouer avec l appareil m me sous supervision Dans la mesure du possible toujours d brancher l appareil lorsqu il n est pas utilis Ne pas faire fonctionner un appareil de chauffage si le cordon lectrique ou la fiche sont ab m s apr s une d fectu osit de l appareil ou si ce der
3. alimentaci n a la unidad Primero coloque el interruptor de alimentaci n principal en la posici n OFF apagado Luego retire el enchufe el ctrico del tomacorriente de pared gt gt gt gt S 6 GARANTIA DE 1 ANO Para modelos de Chimeneas El ctricas Twin Star GARANTIA BASICA DE 1 ANO Twin Star International Inc de aqui en adelante denominado la Compa a de manera colec tiva garantiza que su nueva Chimenea El ctrica Twin Star est libre de defectos de fabricaci n y de materiales durante un per odo de un a o a partir de la fecha de compra sujeto a las siguientes condiciones y limitaciones Esta chimenea el ctrica deber instalarse y oper arse en todo momento de acuerdo con las instruc ciones de instalaci n y operaci n suministradas con el producto Toda reparaci n alteraci n abuso intencionado accidente o mala utilizaci n del producto que no est autorizada anular esta garant a 2 Esta garant a no es transferible y se otorga al pro pietario original siempre y cuando la compra se haya realizado a trav s de un proveedor autorizado de la compa a 3 La garant a est limitada a la reparaci n o la reposici n de piezas que se hayan encontrado defectuosas en relaci n con la mano de obra o el material siempre y cuando estas piezas hayan sido sometidas a condiciones normales de uso y man tenimiento luego de que dicho defecto haya sido confirmado por la inspecci
4. aux codes locaux et la norme ANSI NFPA 70 du National Electrical Code Un limiteur de thermostat est situ l int rieur de l appareil de chauffage Lorsque la temp rature interne devient trop lev e ou varie de fa on anormale le limiteur de thermostat coupe l alimentation afin d viter des dommages au foyer ou des risques d incendie F 2 18 19 20 21 22 23 24 Les appareils de chauffage ne doivent pas tre install s directement sous une prise de courant N ins rer aucun objet dans la ventilation ou la bouche d vacuation car cela pourrait causer des chocs lectriques un incendie ou des dommages l appareil Pour viter un incendie ne bloquer d aucune fa on les entr es ou sorties d air Ne pas utiliser cet appareil sur une surface molle comme un lit o les ouvertures pourraient tre bloqu es l int rieur de cet appareil se trouvent des pi ces chaudes qui produisent des tincelles Ne pas utiliser cet appareil dans un endroit o sont entrepos s ou utilis s des liquides inflammables comme de l essence de la peinture ou autre Cet appareil ne doit pas tre utilis comme s choir pour les v tements et il ne faut pas accrocher les bas et d corations de No l proximit Utiliser uniquement cet appareil de la fa on prescrite dans ce manuel Tout autre usage non recommand par le fabricant pourrait causer un incendie un choc lectrique ou des
5. n de la Compa a 4 Seg n su criterio la Compa a podr cumplir con todas las obligaciones con respecto a esta garant a al reembolsar el precio mayorista de las piezas defectuosas 5 Todos los costos de instalaci n mano de obra construcci n transporte u otros gastos que sur jan de las piezas defectuosas la reparaci n la reposici n o similares no estar n cubiertos por esta garant a ni la Compa a asumir la respon sabilidad de stos 6 El propietario usuario asume todos los otros ries gos si los hay que incluyen el riesgo de cualquier p rdida o da o directo indirecto o resultante que surja del uso o la incapacidad para usar el produc to a excepci n de lo dispuesto por ley p Servicio de atenci n al cliente Correo electr nico parts twinstarhome com L nea para llamadas en ingl s 800 318 9373 L nea para llamadas en espa ol 800 318 9373 L nea para llamadas en franc s 800 318 9374 7 Por la presente se excluyen expresamente todas las otras garant as ya sean expl citas o impl citas con respecto al producto sus componentes y acceso rios o cualquier obligaci n responsabilidad por parte de la Compa a 8 La compa a no asume ni autoriza a ning n ter cero a asumir en su nombre ninguna otra respon sabilidad con respecto a la venta del producto Twin Star 9 Las garant as tal como se describen en este docu mento no se aplican a accesorios que no sean de Twin Star y
6. que se utilicen en conjunto con la instalaci n de este producto 10 Esta garant a le otorga derechos legales espec ficos y es posible que usted tenga otros derechos que var an seg n el estado Donde usted v ve Esta garant a no tendr validez en caso de que a La chimenea sea sometida a per odos prolongados de humedad o condensaci n b Toda alteraci n abuso intencionado accidente o mala utilizaci n del producto que no est auto rizada c No tenga el recibo original de la compra SI NECESITA UTILIZAR LA GARANT A Comun quese con la Compa a a parts twinstarhome com O llame al l nea en ingl s 800 318 9373 l nea en franc s 800 318 9374 l nea en espa ol 800 318 9373 Aseg rese de tener la garant a el recibo de venta el lugar de la compra y el n mero de modelo serie de su producto Twin Star Para obtener las actualizaciones y revisiones de este manual visite nuestro sitio Web www twinstarhome com instructions Twin Star International Inc Delray Beach FL 33445 U S A Fabricado en China Impreso en China 2009 Twin Star International Inc FOYER LECTRIQUE ENCASTRABLE FOYER LECTRIQUE NON RACCORD AVEC CHAUFFAGE MANUEL DU PROPRI TAIRE MODELES DFIO16ARA DFIO16ARU DFIO20ARA DFIO20ARU RENSEIGNEMENTS SUR LA S CURIT VEUILLEZ LIRE CE GUIDE AVANT D INSTALLER ET D UTILISER CET APPAREIL AVERTISSEMENT NE PAS SUIVRE LA LETTRE LES RENSEIGNEME
7. 16ARU DFIO20ARA DFIO20ARU CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE USING THIS APPLIANCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE Thank you and congratulations on your purchase of a Twin Star International Inc Twin Star fireplace Please read the Operating Instructions before using this appliance IMPORTANT Read all instructions and warnings carefully before using this appliance Failure to follow these instructions may result in a possible electric shock fire hazard and or injury and will void the warranty For Customer Service E mail parts twinstarhome com In English Call 800 318 9373 In Spanish Call 800 318 9373 In French Call 800 318 9374 Made in China Printed in China WARNING THIS IS AN UNVENTED ELECTRIC APPLIANCE DO NOT ATTEMPT TO BURN WOOD OR MANUFACTURED FIRELOGS IN OR ON THIS APPLIANCE OR GRATE ATTENTION ALSO Requires Wood Fireplace Mantel Distributed by Twin Star International Inc Under license duraflame and the duraflame flame logo are trademarks of Duraflame Inc Twin Star International Inc Delray Beach FL 33445 lade in China Printed in Chin IMPORTANT INSTRUCTIONS When using electrical appliances ba
8. 800 318 9374 INSTRUCTION MANUAL ENCLOSED MANUEL D INSTRUCTION L INT RIEUR MANUAL DE INSTRUCCIONES ADJUNTO
9. AAA Ne jamais liminer les piles par incin ration sauf lorsqu il s agit d une incin ration contr l e le non respect de cette mise en garde peut entra ner une explosion ENTRETIEN Les moteurs du ventilateur et du g n rateur de flammes sont pr lubrifi s pour une dur e prolong e des roulements et ne requi rent aucune lubrification additionnelle Toutefois il est recommand de nettoyer et de passer l aspirateur r guli rement l int rieur du ventilateur et de l appareil de chauffage S assurer que l unit est en position ARR T et d branch e au moment de nettoyer le l appareil de chauffage ou le foyer AVERTISSEMENT S assurer que l appareil est d branch avant de commencer Toute r paration lectrique ou tout remplacement du c blage lectrique de cette unit devrait tre effectu par un lectricien agr conform ment aux codes nationaux et locaux Au moment de la r paration ou du remplacement de pi ces lectriques ou du c blage le routage original des c bles les codes de couleurs et la s curit des lieux doivent tre respect s AVERTISSEMENT Le raccordement des prises lectriques doit tre conforme aux codes du b timent locaux et tout autre r glement en vigueur afin de r duire les risques d incendie de choc lectrique et de blessures corporelles AVERTISSEMENT Ne pas utiliser cet appareil s il a t en tout ou en partie immerg dans l eau Communiquer imm
10. AT Calor enciende y apaga la salida de calor Una vez que se encienda el calentador la unidad demorar varios segundos en comenzar a emitir aire caliente El indicador de calor est in stalado en el conjunto de le os Cuando la unidad est encendida el conjunto de le os se iluminar para indicar que la unidad est encendida TEMPERATURA La perilla de control TEMPERATURE Temperatura regula el nivel de temperatura del calentador Cuanto m s se gire la perilla en el sentido de las agujas del reloj mayor ser la temperatura de punto de ajuste Al girar la perilla en sentido opuesto a las agujas del reloj se disminuir la temperatura de punto de ajuste Use esta funci n para regular el nivel de temperatura ambiente ADVERTENCIA Durante el mantenimiento de este aparato deber apagarse la alimentaci n a la unidad Primero coloque el interruptor de alimentaci n principal en la posici n de apagado O A continuaci n retire el enchufe el ctrico del tomacorriente de pared Modelos DFIO16ARA DFIO16ARU DFIO20ARA DFIO20ARU S 5 FUNCIONES DEL CONTROL REMOTO CONTROL REMOTO CON 4 BOTONES NOTA El interruptor de alimentaci n principal de la unidad debe estar en la posici n de encendido para que el control remoto funcione ENERG A El bot n Power Energ a colocar al hogar en modo de espera De esta
11. INSTRUCTION MANUAL ENCLOSED MANUEL D INSTRUCTION A LINTERIEUR MANUAL DE INSTRUCCIONES ADJUNTO DH amnion Y IF YOU HAVE ANY PROBLEMS OR QUESTIONS EMAIL OR CALL CUSTOMER SERVICE BEFORE YOU RETURN THIS PRODUCT TO THE STORE WHERE IT WAS PURCHASED For Customer Service email parts twinstarhome com in English Call 800 318 9373 in Spanish Call 800 318 9373 in French Call 800 318 9374 arnc n SI TIENE ALG N PROBLEMA O PREGUNTAS ENVIE UN MENSAJE DE CORREO ELECTRONICO O LLAME AL SERVICIO DE ATENCION AL CLIENTE ANTES DE DEVOLVER ESTE PRODUCTO A LA TIENDA EN LA QUE LO COMPRO Servicio de atenci n al cliente Correo electr nico eo RON L nea para llamadas en ingl s 800 318 9373 L nea para llamadas en espa ol 800 318 9373 L nea para llamadas en franc s 800 318 9374 amnion Q SI VOUS AVEZ DES PROBL MES OU DES QUESTIONS ENVOYEZ UN COURRIEL AU SERVICE LA CLIENT LE OU APPELEZ LE SERVICE LA CLIENT LE AVANT DE RETOURNER CE PRODUIT O VOUS L AVEZ ACHET Pour le service la client le courriel parts twinstarhome com pour le service en anglais appelez au 800 318 9373 pour le service en espagnol appelez au 800 318 9373 pour le service en fran ais appelez au 800 318 9374 INSTRUCTION MANUAL ENCLOSED MANUEL D INSTRUCTION L INT RIEUR MANUAL DE INSTRUCCIONES ADJUNTO ELECTRIC FIREPLACE FIREPLACE INSERT HOMEOWNERS OPERATING MANUAL MODELS DFIO16ARA DFIO
12. MME ajuster la temp rature ambiante Chaque fois que l utilisateur appuie sur le bouton FLAMME l intensit de la flamme diminue AVERTISSEMENT L unit doit tre d branch e pendant Six niveaux d intensit peuvent tre s lectionn s de l entretien ou la r paration de l appareil D abord placer le mani re cyclique y compris la mise l arr t commutateur principal la position OFF Arr t O Puis position ARRET retirer la fiche lectrique de la prise murale 20 CHALEUR Le bouton CHALEUR permet d allumer et d teindre la sortie de chaleur Lorsque l appareil de chauffage est r gl a la position MARCHE il faudra quelques secondes a l unit pour commencer souffler de l air chaud L indicateur de chaleur a t install dans l ensemble pour b ches Lorsque l unit est r gl e la position MARCHE l ensemble de b ches s allume pour indiquer que l unit est en marche Modelos DFIO16ARA DFIO16ARU DFIO20ARA DFIO20ARU F 5 FONCTIONS DE LA TELECOMMANDE T L COMMANDE QUATRE BOUTONS NOTE Il est n cessaire de r gler l interrupteur principal de l unit la position ON pour activer la t l commande D ALIMENTATION Le fait d appuyer sur le bouton d alimentation met le po le encastrable en mode d attente Cela aura pour effe
13. NTS INDIQU S DANS CE GUIDE POURRAIT ENTRA NER UN CHOC LECTRIQUE UN INCENDIE DES BLESSURES OU LE D C S NE PAS CONSERVER OU UTILISER D ESSENCE OU TOUT AUTRE LIQUIDE OU SOURCE DE VAPEURS INFLAMMABLES PR S DE CET APPAREIL O DE TOUT AUTRE APPAREIL DU M ME TYPE Nous vous remercions et vous f licitons d avoir achet un foyer demarque Twin Star International Inc Twin Star Veuillez lire les instructions d installation et d utilisation avant de faire fonctionner cet appareil IMPORTANT Veuillez lire attentivement toutes les instructions et tous les avertisse ments avant de commencer l installation de l appareil Ne pas se conformer ces instruc tions pourrait entra ner un choc lectrique un risque d incendie et ou de blessure en plus d annuler la garantie a ant la AVERTISSEMENT IL S AGIT D UN Pour le service la client le ATTENTION Pb eee Gch Courriel parts O twinstarhome com Exige AUSSI VENTIL NE PAS TENTER DE FAIRE en anglais composez le 800 318 9373 BR LER DU BOIS OU DES B CHES en espagnol composez le 800 318 9373 Manteau en bois pour foyer FABRIQU ES DANS L APPAREIL en fran ais composez le 800 318 9374 OU SUR LA GRILLE Fabriqu en Chine Imprim en Chine INSTRUCTIONS IMPORTANTES Lors de l utilisation d appareils lectriques pour viter les risques d incendie d lectrocution et de blessures toujours suivre les consignes de s curit de base suivantes
14. blessures corporelles viter l utilisation d une rallonge lectrique qui pourrait surchauffer et cr er des risques d incendie Toutefois s il est n cessaire d utiliser une rallonge lectrique celle ci devra tre d un calibre minimal de 14 AWG et d une capacit nominale d au moins 1 875 W La rallonge doit tre compos e de trois fils conducteurs avec une fiche de mise la terre et ne pas d passer 6 m 20 pi de long Consulter les directives la figure 1 Cet appareil de chauffage a t con u pour tre utilis sous une tension de 120 V La fiche du cordon est montr e la figure 1 Consulter la figure 1 afin de prendre connaissance des instructions de mise la terre L adaptateur montr en C est disponible pour brancher des fiches trois branches avec mise la terre dans des prises deux fentes La fiche verte de mise la terre qui sort de l adaptateur doit tre reli e une bo te de sortie convenablement mise la terre L adaptateur ne doit pas tre utilis lorsqu une prise mise la terre trois fentes est disponible Figure 1 COUVERCLE DE LA BO TE DE PRISES MISES LA TERRE VIS DE M TAL BROCHE DE MISE A LA TERRE ADAPTATEUR MISE LA TERRE SIGNIFIE BROCHE DE MISE LA TERRE CONSERVER CES INSTRUCTIONS POSITION DES COMPOSANTS DU PRODUIT B ches Et Lit De Braises Cordon D alimentation Et Pris
15. de TEMPERATURA se encuentre en la configuraci n Hi Alta 4 El calentador de la unidad no funciona 4a UBICACI N DE LA REPISA Al elegir una ubicaci n para su nueva chimenea aseg rese de seguir las instrucciones generales Adem s a fin de obtener los mejores resultados instale la chimenea de manera que no est en contacto con la luz del sol Recomendaci n para la instalaci n en climas fr os Al instalar esta unidad contra un compartimiento o una pared exterior sin aislamiento es obligatorio aislar las paredes externas conforme con los c digos correspondientes de aislamiento CONEXI N EL CTRICA Se requiere un circuito de 60 Hz 15 AMP y 120 voltios con un tomacorriente correctamente conectado a tierra Preferentemente la chimenea deber estar en un circuito especial ya que otros aparatos en el mismo circuito podr an causar que se desconecte el interruptor de circuito o que se queme el fusible cuando el calentador est funcionando La unidad viene de serie con un cable trifilar de 1 8 metros 6 pies que sale de la parte trasera de la chimenea Planifique la instalaci n de modo de evitar el uso de un cable prolongador Si es necesario Coloque todos los interruptores en la posici n de apagado O y desenchufe la unidad del tomacorriente de pared durante cinco 5 minutos Transcurridos ese lapso enchufe nuevamente la unidad al tomacorriente y sela normalmente usar un cable prolongador ste d
16. de llama est n lubricados previamente para proporcionar una vida til m s prolongada a los rodamientos y no requieren lubricaci n adicional No obstante se recomienda limpiar aspirar peri dicamente la unidad del ventilador calentador Ase g rese de que la unidad est APAGADA y desenchufada siempre que limpie el calentador o la chimenea ADVERTENCIA Aseg rese de que la energ a est cortada antes de continuar Toda repa raci n o renovaci n del sistema el ctrico de la unidad deber ser realizada por un elec tricista autorizado de acuerdo con c digos nacionales y locales En caso de reparar o cambiar cualquier componente el ctrico o cableado deber seguirse la ruta de cables el c digo de colores y los lugares de sujeci n originales ADVERTENCIA El cableado del tomacorriente el ctrico debe cumplir con los c digos de edificaci n locales y otras normas aplicables a fin de reducir el riesgo de incendio des carga el ctrica y lesiones a personas ADVERTENCIA No utilice esta chimenea si alguna de sus piezas ha estado sumergida en agua Llame inmediatamente a un t cnico de mantenimiento calificado para que inspeccione la chimenea y cambie cualquier pieza del sistema el ctrico ADVERTENCIA Desconecte la alimentaci n antes de intentar realizar mantenimiento o limpieza a fin de reducir el riesgo de incendio descarga el ctrica o lesiones personales ADVERTENCIA Durante el mantenimiento de este aparato deber cortarse la
17. de tres ranuras Figura 1 TAPA DE LA CAJA DE DISTRIBUCI N CON CONEXI N A TIERRA o TORNILLO MET LICO CLAVIJA DE CONEXI N A TIERRA A B C ADAPTADOR US CLAVIJA DE CONEXI N A TIERRA o CLAVIJA DE CONEXI N A TIERRA GUARDE ESTAS INSTRUCCIONES INFORMACI N DE ORIENTACI N DEL PRODUCTO Le os Y Lecho De Brasas Cable De Energ a Y Enchufe Placa Frontal Panel De Controles Conjunto De Calentador ventilador LISTA DE PIEZAS e remosae AAA Pela para co de empereur C memor alimentaci n piepal SR o al a RS SS Motor de accionamiento del generador de llama CELL SK Xx SES lt S IS xs S 3 GU A DE RESOLUCI N DE PROBLEMAS PROBLEMA SOLUCI N 1 No hay energ a el interruptor de alimentaci n se encuentra en la posici n de encendido NI 2 Los le os se encienden pero el efecto de llama no funciona d c 3 El efecto de llama funciona pero el calentador 3a no emite aire caliente 1 Compruebe que la unidad est enchufada en un tomacorriente de 120 V est ndar 2 Compruebe que el motor de accionamiento del generador e llama funcione en caso contrario llame al servicio al liente Coloque el bot n del CALENTADOR en la posici n de encendido apagado varias veces para asegurarse de que se encuentra en la posici n de encendido 3b Aseg rese de que la perilla
18. der no circumstance should this fireplace be modified Parts having to be removed for servicing must be replaced prior to operating this fireplace again 11 Do not use outdoors 12 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this appliance where it may fall into a bathtub or other water container 13 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over 14 To discomnect this appliance turn controls to the off position then remove plug from outlet 15 Connect to properly grounded outlets only 16 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the current CSA C22 1 Canadian Electrical Code or for U S A installations follow local codes and the National Electrical Code ANSI NFPA NO 70 17 There is a thermostat limiter inside the heater When the inner temperature over heats or abnormal heating occurs the thermostat protective device will cut off the power supply to avoid damage to the fireplace or risk of fire 18 19 20 2 ha 22 23 24 E 2 The heaters must not be located immediately below a socket outlet Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or dama
19. diatement avec un technicien qualifi en entretien et en r paration pour qu il inspecte le foyer et remplace les pi ces du syst me lectrique AVERTISSEMENT D brancher l alimentation lectrique avant l entretien ou le nettoyage afin de r duire les risques d incendie de choc lectrique ou de blessures corporelles AVERTISSEMENT L unit doit tre d branch e pendant l entretien ou la r paration de l appareil D abord placer le commutateur principal la position ARRET Puis retirer la fiche lectrique de la prise murale gt gt gt gt gt F 6 GARANTIE LIMIT E D UN AN Pour les mod les de foyer lectrique Twin Star GARANTIE DE BASE Twin Star International Inc ci apr s appel collec tivement la soci t garantit que votre nouveau foyer lectrique Twin Star sera libre de tout d faut de fabrication pendant une p riode d un an compter de la date d achat sous r serve des conditions et des limites suivantes 1 Ce foyer lectrique doit tre install et fonction ner en tout temps conform ment aux instruc tions d installation et d utilisation fournies avec le produit Toute r paration ou modification non autoris e toute utilisation abusive tout accident ou toute mauvaise utilisation du produit annulera la pr sente garantie 2 Cette garantie est non transf rable et ne vise que l acheteur original la condition que l achat ait t effectu par le biais d
20. e De Courant Plaque Avant Panneau De Commande Ensemble Chaufferette soufflante LISTE DES PIECES Nom De La Pi ce DFIO16ARA DFIO20ARU Ensemble chaufferette soufflante ae ENE AE Bouton de contr le de la temp rature de la chaufferette a a O iia Interrupteur principal AAA a A principale Carte Carte de circuits imprim s du panneau de commande circuits imprim s du panneau de commande E ERRERA Moteur du g n rateur de flammes Poy AA cnc capa dramas PA v e MAT PE ERP EE EEE xXx Xx SR lt S SS SS Jf lt ih ls SEIE l DOS xXx xXx Xx F 3 GUIDE DE DEPANNAGE PROBLEME SOLUTION 1 Il n y a pas d alimentation lectrique m me lorsque l interrupteur est r gl la position MARCHE 1 S assurer que l unit est branch e dans une prise standard de 120 V 2 Les b ches s illuminent mais aucun effet de flammes ne s active 2 S assurer que le moteur du g n rateur de flammes fonctionne Sinon communiquer avec le service a la client le 3a Essayer de r gler le bouton CHAUFFERETTE la position ON et la position OFF plusieurs reprises afin de s assurer qu il est r gl la position ON 3b S assurer que le bouton TEMP RATURE Tem perature est r gl la position HI lev 3 Il y a un effet de flammes mais la chaufferette ne souffle pas d air chaud 4a R gler
21. e ce manuel veuillez consulter notre site web www twinstarhome com instructions Twin Star International Inc Delray Beach FL 33445 U S A Fabriqu en Chine Imprim en Chine O 2009 Twin Star International Inc INSTRUCTION MANUAL ENCLOSED MANUEL D INSTRUCTION A LINTERIEUR MANUAL DE INSTRUCCIONES ADJUNTO DH amnion Y IF YOU HAVE ANY PROBLEMS OR QUESTIONS EMAIL OR CALL CUSTOMER SERVICE BEFORE YOU RETURN THIS PRODUCT TO THE STORE WHERE IT WAS PURCHASED For Customer Service email parts twinstarhome com in English Call 800 318 9373 in Spanish Call 800 318 9373 in French Call 800 318 9374 arnc n SI TIENE ALG N PROBLEMA O PREGUNTAS ENVIE UN MENSAJE DE CORREO ELECTRONICO O LLAME AL SERVICIO DE ATENCION AL CLIENTE ANTES DE DEVOLVER ESTE PRODUCTO A LA TIENDA EN LA QUE LO COMPRO Servicio de atenci n al cliente Correo electr nico eo RON L nea para llamadas en ingl s 800 318 9373 L nea para llamadas en espa ol 800 318 9373 L nea para llamadas en franc s 800 318 9374 amnion Q SI VOUS AVEZ DES PROBL MES OU DES QUESTIONS ENVOYEZ UN COURRIEL AU SERVICE LA CLIENT LE OU APPELEZ LE SERVICE LA CLIENT LE AVANT DE RETOURNER CE PRODUIT O VOUS L AVEZ ACHET Pour le service la client le courriel parts twinstarhome com pour le service en anglais appelez au 800 318 9373 pour le service en espagnol appelez au 800 318 9373 pour le service en fran ais appelez au
22. eber ser como m nimo N 14 AWG trifilar con conector de enchufe de conexi n a tierra y clasificaci n no inferior a 1875 vatios El cable no deber tener m s de 6 metros 20 pies de longitud ESPECIFICACIONES EL CTRICAS Voltaje 120 VCA 60 Hz 11 7 Amperios 1400 Vatios DISTANCIA DE MATERIALES INFLAMABLES Mantenga cables el ctricos cortinados muebles y otros materiales inflamables a un minimo de 0 9 metros 3 pies de distancia de la parte frontal del calentador y alejados de los laterales LIMPIEZA DE LA MOLDURA Limpie la moldura met lica con un pa o suave humed ecido con un producto a base de aceite c trico y p lalo con un pa o suave y limpio NO utilice productos de limpieza dom sticos ni limpiametales ya que estos productos da ar n la moldura met lica Los productos a base de aceite c trico pueden conseguirse en super mercados o ferreter as Amperaje Vatios INSTRUCCIONES DE OPERACI N Y FUNCIONES DE LOS CONTROLES C ENCENDIDO El interruptor POWER Energ a suministra energ a a todas las funciones de la chimenea Este interruptor debe estar en la posici n de encendido para ejecutar cualquier funci n incluso para que funcione el control remoto LIAMA Cada vez que se presiona el bot n FLAME Llama la intensidad de la llama disminuye Hay seis niveles de brillo entre los que puede elegir incluida la op ci n de apagado O 222 CALOR El bot n HE
23. eptacle is available Figure 1 COVER OF GROUNDED OUTLET BOX GROUNDING PIN ADAPTER GROUNDING MEANS GROUNDING PIN SAVE THESE INSTRUCTIONS PORDUCT ORIENTATION Logs And Emberbed Power Cord And Plug Faceplate trol Panel Heater Blower Control Pane Assembly PARTS LIST DFIOI6ARA DFIO20ARA DFIO16ARU DFIO20ARU Logs amp Emberbed pov we EA Y Y K y y Heater Blower Assembly Thermost Y RE HE PE MainPowerSwiteh o O J Y y Wain Conor ira cont Par Cireut Board 7 7 Cremers AE _ Flame Generator Drive Motor v Yo vyv v Creme Geneom A Remote Conte 4 Buts 7 SR ER RIRE NES ENS ENENEN is IRIS RR lt S E 3 TROUBLE SHOOTING GUIDE Sas ene Sean 7 1 Check that the unit is plugged into a standard 1 No power the power switch is in ON position 120V outlet 2 Check whether Flame Generator drive motor is running If not call the customer service 2 Logs Glow flame effect does not work 3a Try to trun ON OFF HEATER button several times to make sure it is in ON position 3b Make sure that the TEMPERATURE knob is set to the max setting 3 Flame effect operates but heater does not blow warm air 4 Turn all switches to the o OFF position and unplug the unit from the wall outlet for 5 minutes After 5 minutes plug the unit back into the wall outlet and operata
24. ge the appliance To prevent a possible fire do not block air intakes or exhaust in any manner Do not use on soft surfaces like a bed where opening may become blocked This appliance has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored This fireplace should not be used as a drying rack for clothing Christmas stockings or decorations should not be hung in the area of it Use this appliance only as described in the manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons Avoid the use of an extension cord because the extension cord may overheat and cause risk of fire However if you have to use an extension cord the cord must be No 14 AWG minimum size and rated not less than 1875 Watts The extension cord must be a three wire cord with grounding type plug and cord connection The extension cord shall not be more than 20 feet 6 m in length See directions in Figure 1 This heater is for use with 120 Volt outlet The cord has a plug as shown in Figure 1 See Figure 1 for grounding instructions An adapter as shown at C is available for connecting three blade grounding type plugs to two slot receptacles The green grounding plug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded rec
25. i nuidas o con falta de experiencia o conocimiento a menos que sean supervisados o que hayan recibido instrucciones Los ni os deber n ser supervisados para que no jueguen con el aparato Si es posible siempre desenchufe este aparato cuando no est en uso No opere ning n calentador con un cable o enchufe da ado o luego de que ste funcione incorrectamente o si se cae o se da a de cualquier manera Si se da a el cable provisto deber ser reemplazado por el fabricante su agente de servicios o personas con ca pacitaci n similar a fin de evitar peligros Todas las reparaciones a esta chimenea deber n ser realizadas por una persona calificada de mantenimiento En ninguna circunstancia podr modificarse esta chi menea Las piezas que se hayan retirado para reali zarles el mantenimiento deber n volver a colocarse antes de operar esta chimenea nuevamente No utilice el aparato en exteriores Este calentador no est dise ado para su uso en ba os reas de lavado ni lugares interiores similares Nunca coloque este aparato en un lugar desde el que podr a caer a una ba era o a otro recipiente con agua No pase el cable debajo de una alfombra No cubra el cable con alfombras peque as tapetes o elementos similares Coloque el cable lejos de las reas de paso y donde no ocasione tropezones Para desconectar este aparato coloque los controles en la posici n de apagado y luego retire el enchufe del tomacorriente S
26. lo conecte el aparato a tomacorrientes con una conexi n a tierra adecuada Al instalar este aparato ste deber contar con una conexi n el ctrica a tierra de acuerdo con c digos locales o en ausencia de c digos locales con el C digo Canadiense de Electricidad vigente norma CSA C22 1 o para las instalaciones en EE UU de acuerdo con c digos locales y el C digo Nacional de Electricidad ANSI NFPA N 70 Hay un limitador termost tico dentro del calentador Si la temperatura interna se sobrecalienta u ocurre un calentamiento anormal el dispositivo de protecci n del termostato corta el suministro de energ a para evitar da os a la chimenea o que se genere un riesgo de incendio S 2 18 19 20 21 22 23 24 Los calentadores no deben colocarse inmediatamente debajo de un tomacorriente No introduzca ni permita que objetos extra os ingresen a ninguna abertura de ventilaci n o escape ya que esto podr a causar una descarga el ctrica o incendio o podr a da ar el aparato A fin de evitar un posible incendio no bloquee las entradas ni las salidas de aire de ninguna manera No utilice el aparato sobre superficies blandas como una cama donde la abertura podr a bloquearse Este aparato tiene piezas calientes y piezas que producen arcos el ctricos o chispas en el interior No lo utilice en reas donde se usen o guarden l quidos inflamables gasolina o pintura Esta chimenea no debe utilizarse c
27. lt in an explosion MAINTENANCE The motors used on the fan and the flame generator assembly are pre lubricated for extended bearing life and require no further lubrication However periodic cleaning vacuuming of the fan heater unit is recommended Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace WARNING Make sure the power is turned off before proceeding Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes If repairing or replacing any electrical component or wiring the original wire routing color coding and securing locations must be followed WARNING Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electrical shock and injury to persons WARNING Do not use this fireplace if any part of it has been under water Immediately call a qualified service technician to inspect the fireplace and replace any part of the electrical system Warning Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire electrical shock or personal injury Warning During any service of this appliance the power to the unit must be turned off First turn the main power switch to the OFF position Then remove the electrical plug from the wall outlet E 6 1 YEAR LIMITED WARRANTY Twi
28. manera se apagar n todas las funciones simult neamente pero se mantendr n los ajustes en la memoria Al presionar el bot n otra vez la unidad se encender nuevamente con los mismos ajustes LLAMAS Cada vez que se presiona el bot n FLAME Llama la intensidad de la llama disminuye Hay seis niveles de brillo entre los que puede elegir incluida la opci n de apagado OFF 20 CALOR El bot n HEAT Calor encender y apagar la alimentaci n al calentador y al ventilador impelente Una vez que se encienda el calentador la unidad demorar varios segundos en comenzar a emitir aire caliente El interruptor giratorio Temperature controla la funci n del termostato para ayudar a regular la temperatura ambiente Pil JUGAR PAUSA Atenci n Empuja los botones del control remoto lento y en una manera controlado Empuja los botones del control Nota La funci n del bot n PLAY PAUSA Jugar Pausa remoto uniformamente y suavamente Empujando los botones se aplica nicamente al modelo ARU Presione este bot n rapidamente y irrefrenable puede causar el control remoto a para activar o pausar el efecto ondulante de la llama funcionar defectuoso Importante Este control remoto usa dos bater as AAA Nunca queme las bater as para desecharlas excepto mediante incineraci n controlada El incumplimiento de esta precauci n puede causar una explosi n MANTENIMIENTO Los motores usados en el conjunto del ventilador y el generador
29. n Star Electric Fireplace Models BASIC WARRANTY Twin Star International Inc hereinafter referred to 7 All other warranties expressed of implied collectively as the Company warrants that your with respect to the product its components and new Twin Star Electric Fireplace is free from accessories or any obligations liabilities on the manufacturing and material defects for a period of part of the Company are hereby expressly excluded one year from date of purchase subject to the 8 The Company neither assumes nor authorizes any third party to assume on its behalf any other following conditions and limitations liabilities with respect to the sale of the Twin Star 1 This electric fireplace must be installed and product operated at all times in accordance with the 9 The warranties as outlined within this document installation and operating instructions furnished do not apply to non Twin Star accessories used in with the product Any unauthorized repair alteration conjunction with the installation of this product willful abuse accident or misuse of the product 10 This warranty gives you specific legal rights and shall nullify this warranty you may also have other rights which vary from 2 This warranty is non transferable and is made to state to state the original owner provided that the purchase was made through an authorized supplier of the company This warranty is void if a The fireplace is subjected t
30. nier a t chapp ou endom mag de quelque fa on Si le cordon d alimentation est endommag il doit tre remplac par le fabricant un de ses agents ou une autre personne qualifi e afin d viter tout danger Confier la r paration du foyer un technicien qualifi Cet appareil ne doit tre modifi en aucun cas Les pi ces retir es pour entretien ou r paration doivent tre remplac es avant de remettre le po le en marche Ne pas utiliser le produit l ext rieur Cet appareil de chauffage n est pas con u pour tre utilis dans une salle de bain une salle de lavage ou tout endroit semblable Ne jamais le placer l o il pourrait tomber dans une baignoire ou un autre r cipient contenant de l eau Ne pas glisser le cordon lectrique sous un tapis Ne pas recouvrir le cordon d une carpette d un tapis d escalier ou de couloir ou d un autre tapis semblable loigner le cordon des endroits passants et de l o il pourrait faire tr bucher Pour d brancher cet appareil tourner les boutons de r glage en position arr t puis retirer la fiche de la prise de courant Brancher uniquement dans une prise de courant convenable ment mise la terre Une fois install ce foyer doit tre mis la terre conform ment aux codes locaux ou en l absence de tels codes la derni re dition de la norme CSA C22 1 du Code canadien de l lectricit ou si le produit est install aux tats Unis
31. nstructions For Customer Service Twin Star International Inc E mail parts twinstarhome com Delray Beach FL 33445 In English Call 800 318 9373 U S A In Spanish Call 800 318 9373 Made in Chi In French Call 800 318 9374 Predin ta 2009 Twin Star International Inc E 7 INSERTO PARA CHIMENEA EL CTRICA CHIMENEA SIN RESPIRADERO CON CALENTADOR MANUAL DE OPERACI N DEL PROPIETARIO MODELOS DFIO16ARA DFIOT6ARU DFIO20ARA DFIO20ARU INFORMACI N SOBRE SEGURIDAD PARA EL CONSUMIDOR LEA ESTE MANUAL ANTES DE INSTALAR Y OPERAR ESTE APARATO ADVERTENCIA EN CASO DE NO SEGUIR LA INFORMACI N EN ESTE MANUAL CON EXACTITUD PODR AN PROVOCARSE DESCARGA EL CTRICA O INCENDIO Y DA OS A LA PROPIEDAD LESIONES PERSONALES O LA P RDIDA DE LA VIDA NO GUARDE NI USE GASOLINA NI OTROS VAPORES Y L QUIDOS INFLAMABLES EN LA CERCAN A DE ESTE APARATO NI DE CUALQUIER OTRO Gracias y felicitaciones por su adquisici n de una chimenea de Twin Star International Inc Twin Star Lea las Instrucciones de Instalaci n y Operaci n antes de utilizar este aparato IMPORTANTE Lea todas las instrucciones y advertencias con detenimiento antes de comenzar la instalaci n Si no se siguen las instrucciones podr a provocarse riesgo de descarga el ctrica incendio o lesiones y adem s la garant a perder a validez Servicio de atenci n al cliente ADVERTENCIA ESTE ES UN A APARATO ELECTRICO SIN AT E N C l O N Correo electr nic
32. o parts twinstarhome com VENTILACI N NO INTENTE Linea para llamadas en ingl s 800 318 9373 QUEMAR LENOS FABRICADOS NI TAMBI N se requiere L nea para llamadas en espa ol 800 318 9373 MADERA DENTRO O SOBRE ESTE f ne Repisa de chimenea de madera Linea para llamadas en franc s 800 318 9374 APARATO O SU PARRILLA P INSTRUCCIONES IMPORTANTES Al utilizar aparatos el ctricos siempre deber n tomarse precauciones b sicas para reducir el riesgo de incendio descarga el ctrica y lesiones a personas Estas incluyen 1 2 10 11 12 13 14 15 16 17 Lea todas las instrucciones antes de usar este aparato Este aparato se calienta cuando est en uso Para ev itar quemaduras no permita que la piel sin protecci n entre en contacto con superficies calientes Si est n incluidas utilice las manijas para mover este aparato Mantenga los materiales inflamables como muebles almohadas ropa de cama papeles prendas de vestir y cortinas a un m nimo de 1 metro 3 pies de distancia de la parte frontal de este aparato ADVERTENCIA Para evitar el sobrecalentamiento del aparato no cubra el calentador No se puede utilizar en un armario PRECAUCION Siempre que se deje el calentador en funcionamiento y sin atenci n deber tenerse extremo cuidado si hay ni os o personas inv lidas cerca El aparato no debe ser utilizado por ni os o personas con capacidades mentales sensoriales o f sicas dism
33. o prolonged periods of 3 The warranty is limited to the repair or replacement dampness or condensation of part s found to be defective in material or workmanship provided that such part s have been b Any unauthorized alteration willful abuse subjected to normal conditions of use and service accident or misuse of the product after said defect is confirmed by the Company s c You do not have the original receipt of purchase inspection 4 The Company may at its discretion fully discharge IF WARRANTY SERVICE IS NEEDED all obligations with respect to this warranty by refunding the wholesale price of the defective part s Contact the company at parts twinstarhome com 5 Any installation labor construction transportation or call 800 318 9373 in English 800 318 9374 in or other related costs expenses arising from defective French 800 318 9373 in Spanish Make sure you have part s repair replacement or otherwise of same will not be covered by this warranty nor shall the Company assume responsibility for same your warranty your sales receipt location of purchase and the model serialnumber of your Twin Star products 6 The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the product except as provided by law For update and revisions to this manual please see our website www twinstarhome com i
34. omo un soporte para secar ropa No deben colgarse medias para los regalos de Navidad nielementos decorativos cerca del aparato Utilice este aparato nicamente como se describe en el man ual Cualquier otro uso no recomendado por el fabricante podr a causar incendio descarga el ctrica o lesiones a personas Evite el uso de un cable prolongador ya que ste podr a sobrecalentarse y provocar un riesgo de incendio No obstante si es necesario utilizar un cable prolongador ste debe tener un tama o m nimo No 14 AWG medida de conductor estadounidense y una clasificaci n no inferior a 1875 vatios El cable prolongador debe ser un cable trifilar con conexi n de cable y enchufe de conexi n a tierra El cable prolongador no deber tener m s de 6 metros 20 pies de longitud Consulte las indicaciones de la Figura 1 Este calentador debe utilizarse con 120 voltios El cable tiene un enchufe como se muestra en la Figura 1 Consulte la Figura 1 para obtener las instrucciones sobre la conexi n a tierra Est disponible un adaptador como se muestra en la secci n C para conectar enchufes con conexi n a tierra de tres clavijas a recept culos de dos ranuras El enchufe verde de conexi n a tierra que se extiende desde el adaptador debe conectarse a una toma de tierra permanente como una caja de distribuci n con una conexi n a tierra adecuada El adap tador no deber utilizarse si se dispone de un recept culo conectado a tierra
35. sic precautions should always be followed to reduce the risk of fire electrical shock and injury to persons including the following Read all instructions before using this appliance 2 This appliance is hot when in use To avoid burns do not let bare skin touch hot surfaces If provided use handles when moving this appliance Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from the front of this appliance WARNING In order to avoid overheating do not cover the heater It can not be used in a wardrobe 3 CAUTION Whenever the heater is left operating and unattended extreme caution is necessary if children or invalids are nearby 4 The appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction 5 Children should be supervised and not allowed to play with the appliance 6 Ifpossible always unplug this appliance when not in use 7 Do not operate any heater with a damaged cord or plug or after the appliance malfunctions or if it has been dropped or damaged in any manner 8 Ifthe supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 9 Any repairs to this fireplace should be carried out by a qualified service person 10 Un
36. t accessoires ou de toute obligation responsabilit de la part de la soci t sont express ment exclues par les pr sentes 8 La soci t n assume aucune autre responsabilit l gard de la vente du produit Twin Star ni n autorise un tiers assumer une telle responsabilit en son nom 9 Les garanties pr sent es dans ce document ne s appliquent qu aux accessoires de marque Twin Star utilis s dans Pinstallation de ce produit 10 Cette garantie vous conf re des droits particuliers et vous pourriez aussi avoir d autres droits qui varient d une province ou d un tat l autre La pr sente garantie sera annul e si a Le foyer reste pendant de longues p riodes dans un endroit humide ou avec condensation b Des r parations ou modifications non autoris es y sont effectu es s il y a utilisation abusive accident ou mauvaise utilisation du produit c Vous n avez pas la preuve d achat originale SI UN ENTRETIEN VIS PAR LA GARANTI EST REQUIS Veuillez communiquer avec la soci t al adresse parts twinstarhome com ou composez les num ros suivants pour le service en anglais 800 318 9373 pour le service en fran ais 800 318 9374 ou pour le service en espagnol 800 318 9373 Assurez vous d avoir la garantie la preuve d achat originale Yendroit ot le produit a t achet ainsi que les num ros de modele et de s rie de votre produit Twin Star Pour des mises jour et r visions d
37. t d teindre toutes les fonctions en m me temps mais de conserver les r glages en m moire En appuyant de nouveau sur ce bouton l unit est mise en marche en affichant les m mes r glages FLAMME Chaque fois que l utilisateur appuie sur ce bouton l intensit de la flamme diminue Six niveaux d intensit peuvent tre s lectionn s de mani re cyclique y compris la mise l arr t 20 CHALEUR Le fait d appuyer sur ce bouton permet de mettre en marche et l arr t la chaufferette et la soufflante Lorsque l appareil de chauffage est r gl la position MARCHE ON il faudra quelques secondes l unit pour commencer souffler de Pair chaud L interrupteur rotatif TEMPERATURE permet de contr ler la fonction thermostat afin de r gler la temp rature de la pi ce Remarque Assurez vous de conserver un rythme mesur et lent Pil LECTURE PAUSE orsque vous utilisez la t l commande Ainsi lorsque vous rel chez es boutons de celle ci assurez vous de toujours conserver une Note Cette fonction du bouton s applique uniquement au ression gale et douce car appuyer rapidement et plusieurs mod le URV unit r ponse vocale Ce bouton permet eprises sur les boutons de la t l commande pourrait entra ner un d activer ou d interrompre l effet de flamme ondulant mau vais fonctionnement de cette derni re Note Cette t l commande fonctionne avec deux piles
38. te as normal FIREPLACE LOCATION used it must be a minimum 14 AWG three wires with grounding type plug connector and rated When choosing a location for your new fireplace not less than 1875 Watts The cord shall not be ensure that the general instructions are followed e y Gene Also for best effect install the fireplace out of 4 Unit heater does not work direct sunlight ELECTRICAL SPECIFICATIONS Cold climate installation recommendation Voltage 120VAC 60Hz when installing this unit against a Amps 11 7 Amps non insulated exterior wall or chase it is Watts 1400 Watts mandatory that the outer walls be insulated to conform to applicable insulation codes CLEARANCE TO COMBUSTIBLES Keep electrical cords drapery furniture and other SEE PS ee LAA combustibles at least 3 feet 0 9 m from the front of the A 15 AMP 120 Volt 60 Hz circuit with a heater and away from the sides properly grounded outlet is required Preferably the fireplace will be on a dedicated circuit as other CLEANING TRIM appliances on the same circuit may cause the circuit Clean the metal trim using a soft cloth slightly breaker to trip or the fuse to blow when the heater is dampened with citrus oil based product and buff with in operation The unit comes standard with 6 feet a clean soft cloth DO NOT use brass polish or 1 8 m three wire cord exiting from the rear of the household cleaners as these products will damage fireplace Plan the installation
39. to avoid the use of the metal trim Citrus oil based products can be an extension cord If an extension cord must be obtained at supermarkets or hardware stores E 4 OPERATING INSTRUCTIONS CONTROL FUNCTIONS POWER TEMPERATURE The POWER switch supplies power to all of the The TEMPERATURE control knob regulates the tem function of the fireplace This switch must be in perature level of the heater The further the knob is 1 position for any functions including the rotated clockwise the higher the set point temperature remote to work Turning the knob counter clock wise will lower the set point temperature Use this function to help regulate amp LEE the ambient temperature level Each time the FLAME button is pressed the intensity of the flame decreases There are six brightness levels you can cycle through including the O OFF setting WARNING During any service of this appliance the power to the unit must be turned off First turn the main power switch to the O OFF position 22 HEAT Then remove the electrical plug from the wall outlet The HEAT button will turn ON OFF he heat out put When the heater is turned on it will take several seconds for the unit to begin blowing hot air The heat indicator was installed in log set When the unit was ON the log set will be light up to indicate the unit was on Models DFIO16ARA DFIO16ARU DFIO20ARA DFIO20ARU
40. tous les interrupteurs la position O OFF et d brancher l unit de la prise murale pendant cinq minutes Apr s cinq minutes brancher de nouveau l unit dans la 4 La chaufferette ne fonctionne pas prise et l utiliser normalement EMPLACEMENT DU FOYER Au moment de choisir l emplacement du votre nouveau foyer s assurer de bien suivre toutes les instructions De plus pour un meilleur effet placer le foyer loin des rayons directs du soleil Recommandation pour l installation en climat froid lorsque l unit est install e contre un mur ext rieur ou un ch ssis non isol le contre mur doit obligatoirement tre isol selon les codes d isolation en vigueur BRANCHEMENT LECTRIQUE Un circuit de 15 A 120 V 60 Hz avec une prise ad qu atement mise a la terre est n cessaire De pr f rence le foyer devrait avoir un circuit d di puisque d autres appareils branch s sur le m me circuit pourraient d clencher le disjoncteur ou faire griller les fusibles lorsque la chaufferette est en marche L unit standard comprend un cordon lectrique de 1 8 m 6 pi trois fils conducteurs sortant l arri re du foyer Planifier l installation pour viter d avoir utiliser une rallonge lectrique S il est n cessaire d utiliser une telle rallonge elle doit tre d un calibre minimal de 14 AWG et d une capacit nominale d au moins 1 875 W avec trois fils conducteurs et
41. un fournisseur autoris de la soci t 3 La pr sente garantie se limite la r paration ou au remplacement des pi ces jug es d fectueuses tant au niveau du mat riel que de la qualit d ex cution la condition que ces pi ces aient t utilis es dans des conditions normales d utilisation et d entretien une fois que ce d faut aura t confirm dans le cadre de l inspection effectu e par la soci t 4 La soci t pourra sa discr tion se d charger enti rement de ses obligations l gard de la pr sente garantie en remboursant le prix de gros des pi ces d fectueuses 5 Toute installation tout travail toute construction tout transport ou tout autre co t frais connexe d coulant des pi ces d fectueuses de la r paration du remplacement ou autre ne sera pas couvert par la pr sente garantie et la soci t nassume aucune responsabilit a cet gard 6 Le propri taire utilisateur assume tous les autres risques le cas ch ant y compris tout dommage ou perte direct indirect ou accessoire d coulant de Putilisation ou de Pincapacit a utiliser le produit sauf comme le pr voit la loi Pour le service la client le Courriel parts twinstarhome com en anglais composez le 800 318 9373 en espagnol composez le 800 318 9373 en fran ais composez le 800 318 9374 7 Toutes les autres garanties expresses ou implic ites l gard de ce produit de ses composants e
42. une fiche de mise la terre Par ailleurs elle ne doit pas d passer 6 m 20 pi de long SP CIFICATIONS LECTRIQUES Tension 120 V c a 60 Hz 11 7 A 1 400 W D GAGEMENTS DES MAT RIAUX COMBUSTIBLES Garder les cordons lectriques articles de draperie meubles et autres mat riaux combustibles au moins 0 9 m 3 pi de l avant et des c t s de l appareil de chauffage Amp rage Watts NETTOYAGE DU CONTOUR M TALLIQUE Nettoyer le contour m tallique l aide d un linge doux l g rement humect d huile de citron puis polir avec un linge doux et propre NE PAS UTILISER de produits polir le laiton ou de produits de nettoyage domestique car ils pourraient endommager le contour de m tal Les produits base d huile de citron sont disponibles dans les supermarch s ou les quincailleries INSTRUCTIONS D UTILISATION DES FONCTIONS DE CONTR LE O ALIMENTATION TEMPERATURE Le commutateur alimente toutes les fonctions du Le bouton de contr le de la TEMP RATURE permet de foyer Le commutateur doit tre r gl la position r gler le niveau de temp rature de la chaufferette Plus on MARCHE pour permettre l utilisation de tourne le bouton dans le sens horaire plus la temp rature toutes les fonctions ainsi que pour faire fonctionner augmente Tourner le bouton dans le sens antihoraire pour la t l commande abaisser la temp rature Utiliser cette fonction pour aider IS FLA
Download Pdf Manuals
Related Search
Related Contents
Zykon P1 Sanyo CE42FD81-B User's Manual Kompernaß Handelsgesellschaft mbH Burgstraße 21 Betriebsanleitung Watt-Drive INVEOR Ref. : 6605 Audiovox APS 650RS User's Manual MALLINCAM SDI User Manual JetVision Users Guide, Release 2.6 GE EAMD Installation Guide User Manual - Solar Info Copyright © All rights reserved.
Failed to retrieve file