1. Unit Range Resolution Accuracy C 0 C 45 0 2 2 E 32 F 113 0 36 3 6 Operating Environment Temperature 32 to 113 F 0 to 45 C Relative humidity lt 80 Storage Environment Temperature 14 to 122 F 10 to 50 C Relative humidity lt 85 Size 4 72 x 2 76 x 1 04 in 120 X 70 X 26 5mm Weight about 2 5 709 including battery Power Source 1 CR2032 battery or equivalent Battery Replacement When the battery charge indicator changes to the battery is exhausted and should be replaced immediately To replace the battery turn off the instrument use a coin to turn the battery cover clockwise remove the battery cover Replace the exhausted battery with a new one of the same type make sure that the polarity connection is correct Reinstall the battery cover and turn it counter clockwise 4 ux 12 11 09 6 04 PM DAF3010B ANEMOMETRO HOJA DE INSTRUCCIONES A DE 12 11 09 6 04 Descripci n general Felicitaciones por adquirir el medidor de anem metro estilo bol grafo The Seeker circulaci n de aire DAF3010B Este instrumento se puede utilizar para medir la velocidad y la temperatura del aire Caracter sticas Medici n de la velocidad del viento actual promedio o m xima Indicaci n de fr o por viento Medici n de la temperatura en grados Celsius o Fahrenheit Medici n de la velocidad del viento en m s km
2. o The whole display can be divided into s three areas i zo rn g A e Area A is a battery charge indicator Li LILI Li knots fu which indicates the current charge level In of the battery fd B Bs DDDDDDI e Area B is the temperature reading area Area is the wind speed measurement result area the rest of the display A 12 11 09 6 04 Symbol Instruction in in mit m s meters per second id dm qu min Km h kilometers per hour knots ft min feet per minute ra AKS nen ed A knots nautical miles per hour HB H gt opppD DD mph miles per hour current wind speed Wind Force Indicators measurement indicator MAX max wind speed measurement indicator Ave average wind speed measurement indicator Imp battery charge indicator WINDCHILL It appears when the temperature is below 32 F 0 C The number on the wind force indicator which appears on the display indicates the current wind force Operation Instruction 1 To Turn unit on Press the JL button for more than about 3 seconds to turn on the instrument The instrument is in measurement mode and the display shows wind speed temperature and battery charge indicator 2 Selecting Desired Wind Measurement Press and hold the 2 button until wind spee
3. HOLD Button Sert garder l cran les indications actuelles ou sortir du mode de sauvegarde 6 2 Button Sert mettre en marche l instrument ou entrer en mode r glage 5 4 3 7 Capteur de temp rature Description de l affichage cristaux liquides La surface d affichage totale peut tre divis e en trois zones s e La zone A est un indicateur de charge de et Ooo ri A la pile qui indique le niveau de charge actuel LILILLLI Ah 5 de la pile VER Piera mi 8 e La zone B est la zone de lecture B de la temp rature La zone C est la zone de r sultat de la mesure de la vitesse du vent le reste de l cran 0 DAF3010 MANUAL FINAL 12 9 qxp awb 12 11 09 6 04 PM Guide des symboles nnn rn x T m tres par seconde al a mmn 5 kilom tres par heure wax ave pieds par minute g u T miles nautiques par heure 1 FDPDDDDY T miles par heure indicateur de mesure de la Wind Force Indicators vitesse actuelle du vent MAX indicateur de mesure de la vitesse max du vent AVG indicateur de mesure de la vitesse moyenne du vent amp indicateur de charge de la pile WINDCHILL 1 apparait quand la temp rature est inf rieure 0 C Le nombre donn par l indicateur de force du vent qui apparait sur l cran indique la force actuelle du vent Instructions de fonctio
4. DAF3010 MANUAL FINAL 12 9 qxp awb 12 11 09 6 04 PM DAF3010B ANEMOMETER USER S MANUAL CHEN DAFS010B NINAS GENERAL TOOLS 8 INSTRUMENTS 80 White Street New York NY 10013 3567 PHONE 212 431 6100 e FAX 212 431 6499 e TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com Specifications subject to change without notice 2010 GENERAL TOOLS amp INSTRUMENTS NOTICE WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS DAF3010B 1 10 Please read this manual carefully and thoroughly before using this product A A M 12 11 09 6 04 PM General Description Congratulations on your purchase of The Seeker for Airflow DAF3010B Digital Anemometer This instrument can be used to measure the velocity and the temperature of air Features e Measures current average or max wind speed Wind chill indication Temperature measurement in Celsius or Fahrenheit Measures wind speed in m s km h ft min knots or mph Battery status indication Structure 1 Wind Impeller Used to sense wind speed 2 Display 3 C F Button Used to switch between Celsius and Fahrenheit measurements 4 OFF SET Button Used to turn oft the instrument or select desired wind speed measurement HOLD Button Used to hold the present reading or exit the Hold mode ON Button Used to turn on the 5 4 3 instrument or enter the Setting mode 7 Temperature Sensor LCD Instruction a
5. ctual del viento MAX indicador de medici n de la velocidad m xima del viento AVG indicador de medici n de la velocidad promedio del viento amp indicador de carga de la bater a WINDCHILL Aparece cuando la temperatura es inferior a 0 C El n mero del indicador de fuerza del viento que aparece en pantalla indica la fuerza actual del viento Instrucciones de operaci n u N y 1 Para encender la unidad Mantenga presionado el bot n durante m s de 3 segundos para encender el instrumento El instrumento se encuentra en la funci n de medici n en la pantalla se muestra la velocidad y la temperatura del viento adem s del indicador de carga de la bater a 2 Selecci n de la medici n de viento deseada Mantenga presionado el bot n E am hasta que la unidad de velocidad del viento comience parpadear Presione el boton OFF SET para seleccionar la unidad de velocidad de viento o la medici n deseada el s mbolo correspondiente aparecer y parpadear indicando la medici n seleccionada Cuando el s mbolo deseado aparezca y parpadee en la pantalla presione el bot n aw una vez para la confirmaci n la funci n de configuraci n del instrumento se cierra y la funci n de medici n se reactiva 3 Selecci n de C F Cuando el instrumento se encuentra en la funci n de medici n se puede presionar el bot n C F para cambiar entre mediciones en grados Celsius y Fa
6. d unit starts to flash Press the OFF SET button to select the desired wind speed unit or desired measurement The corresponding symbol will appear and flash indicating the currently selected measurement When the desired symbol appears and flashes on the display press the RE button once for confirmation the instrument exits setting mode and returns to measurement mode 3 Selecting C F When the instrument is in measurement mode you can press the C F button to switch between Celsius and Fahrenheit measurements 4 Measurements When the wind impeller turns the display will show wind speed and temperature according your settings When the temperature is below 32 F 0 C the symbol WINDCHILL will appear 12 11 09 6 04 5 Holding measurement In measurement mode press the HOLD button to freeze the current readings the readings flash on the display Press again to return to normal operation 6 Auto shut off If you don t press any button for about 10 minutes the instrument will turn off automatically 7 To turn off the instrument manually Press the OFF SET button for more than about 3 seconds Specifications Wind Speed Measurement Unit Range Resolution Threshold Accuracy m s 0 30 0 1 0 1 f min 0 5905 19 6 19 6 knots 0 58 0 2 0 1 5 of reading km h 0 108 0 3 0 3 mph 0 67 0 2 0 2 Temperature Measurement
7. h ft min nudos o mph Indicaci n del estado de la bater a Estructura 1 Impulsor de viento Se utiliza para detectar 7 la velocidad del viento 2 Pantalla 3 Bot n de C F Se utiliza para cambiar entre mediciones de grados Celsius y Fahrenheit 4 OFF SET Button Se utiliza para apagar 6 el instrumento o seleccionar la medici n de la velocidad del viento deseada 5 HOLD Button Se utiliza para grabar la lectura actual o para salir de la funci n Grabar 6 wm Button Se utiliza para encender el instrumento y acceder la funci n Configuraci n 5 4 3 7 Sensor de temperatura Instrucciones de la pantalla LCD A La pantalla se puede dividir en tres reas En el rea A se encuentra un indicador PH de carga de la bateria el cual muestra C H H H H Rm n el nivel de carga actual MAX ave Ph gy Area B es el rea de lecturas de temperatura E 0 amp e El rea C es el rea de resultados de medici n FDEDDDDS de velocidades del viento el resto de la pantalla A 12 11 09 6 04 Instrucciones de los simbolos nnn m s metros por segundo Li AA 1 1 A km h kil metros por hora MANN Knots 8 ft min 2 pies por minuto AVG nee uu knots millas n uticas por hora l B Bs ppp mph millas por hora fu indicador de medici n de la velocidad Wind m indicators a
8. hrenheit 4 Mediciones Cuando el impulsor de viento gire en la pantalla se mostrar la velocidad y la temperatura del viento seg n la configuraci n Cuando la temperatura sea inferior a 0 C aparecer el s mbolo WINDCHILL DAF3010 MANUAL FINAL 12 9 qxp awb 12 11 09 6 04 PM 5 Guardado de una medici n En la funci n de medici n presione el bot n HOLD para congelar las lecturas actuales las lecturas parpadear n en la pantalla Presione el bot n nuevamente para el funcionamiento normal 6 Apagado autom tico Si no se presiona ning n bot n durante 10 minutos el instrumento se apagar en forma autom tica 7 Para apagar el instrumento en forma manual presione el bot n OFF SET durante m s de 3 segundos Especificaciones Medici n de la velocidad del viento Unidad Rango Resoluci n Umbral Precisi n m s 0 30 0 1 0 1 ft min 0 5905 19 6 19 6 knots 0 58 0 2 0 1 5 of reading km h 0 108 0 3 0 3 mph 0 67 0 2 0 2 Medici n de la temperatura Unidad Rango Resoluci n Precisi n C 0 C 45 C 0 2 2 C 32 F 113 0 36 3 6 Entorno operativo Temperatura 0 a 45 C Humedad relativa 8096 Entorno de almacenamiento Temperatura 10 a 50 C Humedad relativa 8596 Tama o 120 X 70 X 26 5 mm Peso aproximadamente 70 g bater a incluida Fuente de alimentaci n 1 bater a CR2032 o equ
9. ignoter Appuyez nouveau pour revenir au fonctionnement normal 6 Arr t automatique Si vous sur aucun bouton pendant 10 minutes environ l instrument s teindra automatiquement 7 Pour teindre manuellement l instrument Appuyez sur le bouton OFF SET pendant plus de 3 secondes environ Sp cifications Mesure de la vitesse du vent Unit Intervalle Pr cision d affichage Seuil Pr cision m s 0 30 0 1 0 1 ft min 0 5905 19 6 19 6 knots 0 58 0 2 0 1 5 of reading km h 0 108 0 3 0 3 mph 0 67 0 2 0 2 Mesure de la temp rature Unit Intervalle Pr cision d affichage Pr cision C 0 C 45 0 2 2 F 32 F 113 F 0 36 3 6 Environnement de fonctionnement Temp rature 0 45 C Humidit relative lt 80 Environnement de stockage Temp rature 10 50 C Humidit relative lt 85 Dimensions 120 X 70 X 26 5 mm Poids environ 70g avec la pile Alimentation 1 pile CR2032 ou quivalente Remplacement de la pile Quand l indicateur de charge de la pile passe la pile est puis e et doit tre remplac e imm diatement Pour remplacer la pile teignez l instrument utilisez une pi ce de monnaie pour faire tourner le couvercle de la pile dans le sens des aiguilles d une montre retirez le couvercle de la pile Remplacez la pile puis e par une pile neuve du m me type ass
10. ivalente Reemplazo de la bater a Cuando el indicador de carga de la bater a cambia a 7 significa que la bater a se ha agotado y debe reemplazarse de inmediato Para reemplazar la bater a apague el instrumento utilice una moneda para girar la cubierta de la bater a en sentido horario y retire la tapa de la bater a Reemplace la bater a agotada por una nueva del mismo tipo aseg rese de que la conexi n de polaridad sea correcta Reinstale la tapa de la bater a y girela en sentido antihorario 8 A E 12 11 09 6 04 PM DAF3010B ANENOMETRE MODE D EMPLOI 12 11 09 6 04 Description g n rale F licitations pour l achat de votre appareil de an nom tre format stylo DAF3030B The Seeker pour flux d air Cet instrument peut tre utilis pour mesurer la vitesse et la temp rature de l air Caract ristiques Mesure la vitesse actuelle moyenne ou maximum du vent Indication du refroidissement olien Mesure de la temp rature en degr s Celsius ou Fahrenheit Mesure la vitesse du vent en m s km h pied min n uds ou miles par heure Indication de l tat de la pile Structure 1 Moulinet Sert d tecter la vitesse du vent 2 Mfichage 7 3 Bouton C F Sert passer de la mesure en degr s Celsius celle en degr s Fahrenheit et vice versa 4 OFF SET Button Sert teindre l instrument ou s lectionner le mode de mesure de la vitesse du vent souhait 5
11. nnement 1 Pour mettre en marche l appareil Appuyez sur le bouton pendant plus de 3 secondes pour mettre en marche l instrument L instrument est en mode mesure et l cran affiche la vitesse du vent la temp rature et l indicateur de charge de la pile 2 S lectionner le mode de mesure du vent souhait Pressez et maintenez enfonc le bouton En jusqu ce que l unit de la vitesse du vent se mette clignoter Appuyez sur le bouton OFF SET pour s lectionner l unit de vitesse du vent ou le mode de mesure souhait Le symbole correspondant apparaitra et clignotera indiquant le mode de mesure s lectionn actuellement Quand le symbole souhait apparait et clignote l cran appuyez une fois sur le bouton x RE pour confirmer Linstrument sort du mode de r glage et repasse en mode del mesure 3 S lectionner C F Quand l instrument est en mode de mesure vous pouvez appuyer sur le bouton C F pour passer des degr s Celsius aux degr s Fahrenheit et vice versa 4 Mesures Quand le moulinet tourne l cran affiche la vitesse du vent et la temp rature en fonction de vos r glages Quand la temp rature est inf rieure 0 C le symbole WINDCHILL apparait aw 11 DAF3010 MANUAL FINAL 12 9 qxp awb 12 11 09 6 04 PM 5 Garder une mesure l cran En mode de mesure appuyez sur le bouton HOLD pour garder l cran les indications actuelles Elles se mettent alors cl
12. urez vous de respecter les polarit s Remettez le couvercle de la pile et tournez le dans le sens inverse des aiguilles d une montre 12

Download Pdf Manuals

image

Related Search

Related Contents

StarTech.com 1m External Serial Attached SCSI SAS Cable - SFF-8470 to SFF-8088  Uniden DECT1905 Cordless Telephone User Manual  Home Decorators Collection 0805400520 Instructions / Assembly    Spice M-5115 User`s Manual  CyberPower Brics 850ELG  Diamond Multimedia Radeon HD 3850 User's Manual    CU2200 - Velleman    