Home
Gas & Electric Dryer Secadora a gas y eléctrica
Contents
1. SIDE VIEW SIDE VIEW 9 5 cm MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstructions Rigid metal duct is preferred 2 f dryer is exhausted through the floor and area beneath the mobile home is enclosed the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 169840 is available from your dealer 5 Refer to pages 2 and 3 for other important venting requirements 6 Installation MUST conform to current Manufactured Home Construction amp Safety Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes In Canada the CSA Z240 is applicable The dryer is designed under ANSI Z 21 5 1 for HOME USE only A O DO EA Correct Incorrect 2525 coud Incorrect A UNPACKING 1 Using the four shipping carton corner posts two on each side carefully la
2. RECEPT CULO DEL TOMACORRIENTE recept culo NEMA 10 30 R que debe estar ubicado en un lugar al que el cable de alimentaci n el ctrica pueda acceder cuando la secadora est instalada Canad recept culo NEMA 14 30R ALIMENTACI N CAJA PRINCIPAL DE FUSIBLES CON CONDUCTOR NEUTRO EL CTRICA PUESTO A TIERRA TRIFILAR 120 240 VOLTIOS 60 CICLOS FUSIBLES DE ACCI N RETARDADA DE 30 AMP O DISYUNTOR CONDUCTOR NEUTRO INSTALACION SUJETA LOS REGLAMENTOS LOCALES NEMA 10 30R COBRE Secadorasa GAS CIRCUITO Circuito individual derivado de 15 amp con fusibles de 15 amp de retardo m ximo o disyuntor ALIMENTACION ELECTRICA Corriente alterna monof sica 60 Hz 120 voltios trifilar CORDON ELECTRICO La secadora est equipada con NOTA No saque un cord n el ctrico por ning n trifilarpara motivo la espiga 120 voltios de puesta a tierra del enchufe ESPIGA DE PUESTA A TIERRA REQUERIMIENTOS DEL SISTEMA DE ESCAPE Utilice solamente ductos met licos r gidos o flexibles de 4 10 2 cm de di metro m nimo y una caperuza de salida de uso aprobado con registros que giren hacia afuera que se abren cuando la secadora se encuentra en funcionamiento Cuando la secadora se detiene los registros se cierran autom ticamente para evitar las corrientes de aire y la entrada de insectos y roedores Para evitar obstruir la salida mantenga una altura libre m nima de 12 30 5 cm entr
3. 14 MODELOS DE DEBAJO DE MOSTRADOR Y APILADORES DIMENSIONES PARA LA INSTALACION 26 7 8 68 3 cm ES CONEXI N EL CTRICA BAJO DEL MOSTRADOR 34 5 8 87 9 cm 2 9 16 6 5 cm 34 4 u 36 C 91 5 cm T CONEXION DE LA 3 3 4 TUBER A DEGAS 1 2 54 cm 9 5 cm DE 3 8 0 96 cm VISTA POSTERIOR 47 1 2 120 7 cm PUERTA ABIERTA A 90 4 3 8 11 1 cm DISCO OPCI NAL REMOVIBLE PARA VENTILACI N M 7 68 6 cm 3 3 4 9 5 cm VISTA LATERAL MODELOS AUT NOMOS CON CONSOLA SUPERIOR DIMENSIONES PARA LA INSTALACI N 26 7 8 68 3 cm CONEXION ELECTRICA 2 9 16 6 5 cm 13 1 2 34 4 cm 36 91 5 cm CONEXI N DE LA TUBER A DEGAS 1 2 54 cm DE 3 8 0 96cm VISTA POSTERIOR 3 3 4 9 5 cm 47 1 2 120 7 cm PUERTA ABIERTA A 90 4 3 8 11 1 cm DISCO OPCIONAL REMOVIBLE PARA VENTILACION 68 6 cm 3 3 4 9 5 cm VISTA LATERAL INSTALACION EN CASAS MOVILES Eltubo de escape dela secadora DEBE ser instalado hacia el exterior El escape debe colocarse en la parte exterior y no debajo de la casa m vil Debe usarse ducto de metal que no sea combustible El ducto de metal debe tener cuatro pulgadas 10 16 cm de di metro y no tener obstrucciones Es preferible usar ducto de metal que sea r gido Siel tubo de escape de la secadora corre a trav s del piso y el rea debajo de l
4. 17 Conexiones TIMO 18 Conexi nes el ctricas tera 18 TOT Tm 19 Mirco E E N 19 SEGURIDAD de SECADORA La instalacion y el servicio de la Secadora de ropa se deben realizar por un instalador calificado la agencia de servicio o el surtidor de gas Instale la Secadora de ropa seg n las instrucciones del fabricante y los c digos locales Antes de comenzar la instalaci n lea cuidadosamente estas instrucciones Esto simplificar la instalaci n y asegurar que la secadora se instale correctamente y de manera segura Despu s de completar la instalaci n coloque estas instrucciones cerca de la secadora para referencia futura NOTA La alimentaci n el ctrica para la secadora deber cumplircon los c digos y reglamentos locales y con la ltima edici n del C digo El ctrico Nacional ANSI NFPA 70 o en Canad CSA C22 1 C digo El ctrico Canadiense Parte 1 NOTA La alimentaci n de gas para la secadora deber cumplir con los c digos y reglamentos locales y con la ltima edici n del C digo Nacional para Gases Combustibles ANSI Z223 1 o en Canada CAN CGA B149 12 NOTA La secadora est clasificada para USO DOMESTICO solamente de acuerdo con la norma ANSIZ 21 5 1 o ANSI UL 2158 CAN CSA C22 2 No 112 las ultimas edici nes Esta secadora no serecomienda para uso commercial tal como en restaurantes salones de belleza etc Su seguridad y la seguridad de
5. The following are specific requirements for proper and safe electrical installation of your dryer Failure to follow these instructions can create electrical shock and or a fire hazard This appliance MUST properly grounded Electrical shock can result if the dryer is not properly grounded Follow the instructions in this manual for proper grounding Do not use an extension cord with this dryer Some extension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt creating electrical shock and or fire hazard Locate the dryer within reach of the receptacle for the length power cord to be purchased allowing some slack in the cord Refer to the pre installation requirements in this manual for the proper power cord to be purchased A U L approved strain relief must be installed onto power cord If the strain relief is not attached the cord can be pulled out of the dryer and can be cut by any movement of the cord resulting in electrical shock Do not use aluminum wired receptacle with copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply GROUNDING REQUIREMENTS N
6. the following method must be used to determine if the exhaust system is acceptable 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pressure 15 less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptable Although vertical orientation of the exhaust system is acceptable certain extenuating circumstances could affect the performance of the dryer e Onlythe rigid metal duct work should be used e Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction e Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint e Compression or crimping of the exhaust system will cause Increase in vent restriction The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation EXHAUST DIRECTION All dryers shipped from the factory are set up for rear exhau
7. 30 SRDT calificado para CA m nima de 240 voltios 30 A con 3 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y calificados para uso en secadoras de ropa Vea CONEXIONES EL CTRICAS PARA UN SISTEMA TRIFILAR Tetrafilar la secadora DEBE emplear un cable de alimentaci n el ctrica de 4 conductores tipo NEMA 14 30 SRDT o ST seg n se especifique calificado para CA m nima de 240 voltios 30 amp con 4 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y calificados para uso en secadoras de ropa Vea CONEXIONES EL CTRICAS PARA UN SISTEMA TEIRAFILAR Canad cable de alimentaci n el ctrica de 4 cables instalado en la secadora ADVERTENCIA riesgo de choque el ctrico Electrodom stico puesto a tierra a trav s de un enlace al conductor neutro La puesta a tierra a trav s del neutro est prohibida para 1 instalaciones de circuitos de bifurcaci n nuevos 2 casas rodantes 3 veh culos recreativos y 4 reas cuyas leyes locales no permiten la puesta a tierra a trav s del neutro 1 desconecte el enlace al neutro 2 use un terminal o cable de puesta a tierra para realizar la conexi n segun las leyes locales y 3 conecte el terminal o cable del neutro al neutro del circuito de bifurcaci n como se hace normalmente si el electrodom stico se va a conectar a trav s de un kit de cord n el ctrico use un cable tetrafilar S LO USE CABLES DE COBRE
8. OF FIRE For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life SAVE THESE INSTRUCTIONS Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier PRE INSTALLATION REQUIREMENTS Tools and Materials Required for Installation Phillips head screwdriver Channel lock adjustable pliers Carpenter s level Hat or straight blade screwdriver Duct tape Rigid or flexible metal 4 inch 10 2 cm duct Vent hood Pipe thread sealer Gas Plastic knife RUN ELECTRICAL REQUIREMENTS ELECTRIC Dryer CIRCUIT Individual 30 amp branch circuit fused with 30 amp time delay fuses or circuit breakers Use separately fused circuits for washers and dryers and DO NOT operate a washer and a dryer on the same circuit POWER SUPPLY 3 wire or 4 wire 240 volt single phase
9. c Abra la v lvula de cierre en la tuber a de suministro de gas d Pruebe todas las conexiones aplicando con una escobilla una soluci n jabonosa NUNCA UTILICE UNA LLAMA ABIERTA PARA DETECTAR FUGAS DEGAS 2 Conecte el ducto de escape al sistema de escape exterior Utilice cinta para obturar todas las uniones 3 Con la secadora en su posici n definitiva regule uno o m s tornillos niveladores hasta que la secadora repose firmemente sobre los cuatro tornillos Coloque un nivel sobre la parte superior de la secadora LA SECADORA DEBE ESTAR A NIVEL Y REPOSAR SOLIDA Y FIRMEMENTE SOBRE LOS CUATRO TORNILLOS NIVELADORES Conecte el cord n el ctrico a un tomacorriente puesto a tierra NOTA Aseg rese de que la corriente est desconectada en el disyuntor caja de fusibles antes de conectar el cord n el ctrico en el tomacorriente 5 Conecte la corriente en el disyuntor caja de fusibles Antes de poner en funcionamiento la secadora aseg rese de que no haya materiales combustibles gasolina y otros vapores inflamables cerca de la secadora Adem s aseg rese de que no haya nada tal como cajas ropas etc que obstruya el flujo del aire de combusti n y ventilaci n 6 Haga funcionar la secadora durante un ciclo completo para comprobar su buen funcionamiento NOTA En las secadoras a gas antes de encender el quemador es necesario purgar el aire de la tuber a del gas Siel quemador no enciende dentro de 45 segundos cuando
10. de encender ningun artefacto el ctrico No toque ningun interruptor el ctrico no use ning n tel fono en su edificio Haga salir atodos los ocupantes de la habitaci n del edificio y del lugar Llame a su proveedor de gas desde el tel fono de un vecino Siga las instrucciones del proveedor de gas Sino logra comunicarse con su proveedor de gas llame al departamento de bomberos La nl y el servicio de mantenimiento debe de realizarlos un instalador calificado la agencia de servicios o el proveedor de gas REQUERIMIENTOS DE INSTALACI N PRELIMINARES Herramientas y materiales necesarios para la instalaci n Destornillador Phillips Alicates universales Nivel de carpintero Destornillador para tornillo de cabeza plana o recta Cinta para ductos Ducto met lico r gido o flexible de 4 10 2 cm Caperuza de salida Sellador de tuber as gas Un cuchillo de pl stico ON OY UN Ps WN 11 REQUERIMIENTOS ELECTRICOS Secadoras ELECTRICAS CIRCUITO circuito independiente individual de 30 A con fusibles de acci n retardada o disyuntores Use circuitos con fusibles separados para las lavadoras y secadoras y NO haga funcionar una lavadora y una secadora en el mismo circuito SUMINISTRO EL CTRICO trifilar o tetrafilar 240 V 1 fase 60 Hz corriente alterna CABLE DE ALIMENTACI N EL CTRICA Trifilar la secadora DEBE emplear un cable de alimentaci n el ctrica de 3 conductores tipo NEMA 10
11. del sistema de tuber as de alimentaci n de gas realizado a presiones de prueba de m s de 1 2 Ibs pulg 3 45 kPa 7 Lasecadora DEBE aislarse del sistema de tuber as de alimentaci n de gas durante cualquier ensayo de presi n del sistema de tuber as de alimentaci n de gas realizado en ensayos de presi n iguales o inferiores a 1 2 lbs pulg 3 45 kPa 13 UBICACION DE SU SECADORA NO INSTALE SU SECADORA 1 2 En un lugar donde puede haber goteos de agua o quede expuesta a las inclemencias del tiempo En un rea donde pueda entrar en contacto con cortinas cortinajes o cualquier otra cosa que obstruya el flujo de combusti n y ventilaci n de aire Sobre alfombras El piso DEBE ser firme con un desnivel m ximo de 1 pulgada 2 54 cm INSTALACI N DENTRO DE UN NICHO O ARMARIO 1 Sila secadora es instalada en un dormitorio cuarto de ba o nicho o armario el tubo del escape DEBE ser instalado hacia el exterior No se debe instalar ning n otro artefacto que queme combustible en el mismo armario en que est instalada la secadora a Gas La secadora necesita espacio a su alrededor para una ventilaci n adecuada NO INSTALE LA SECADORA EN UN ARMARIO CON PUERTA MACIZA 60 Pulg 387 1 cm 4 Serequiere como m nimo una abertura de 120 pulgadas cua dradas 774 2 cm dividida equitativamente para la parte superior e inferior de la puerta Cuando se instala una puerta es nece
12. from the power cord and the neutral ground wire from the dryer harness to the silver colored center terminal on the terminal block Tighten the screw securely Attach the red and black power cord conductors to the outer brass colored terminals on the terminal block WINE Do not make a sharp bend or crimp wiring conductor at the connections Tighten the screws securing the cord restraint firmly against the power cord Tighten the strain relief nut securely so the strain relief does not turn Reinstall the terminal block access cover INSTALLATION 1 GAS CONNECTION Gas dryers only a Remove the shipping cap from gas pipe at the rear of the dryer NOTE DO connect the dryer to L P gas service without converting the gas valve An L P conversion kit must be installed by a qualified gas technician b Connect a 1 2 inch 1 27 cm I D semi rigid or approved pipe from gas supply line to the 3 8 inch 0 96 cm pipe located on the back of the dryer Use a 1 2 inch to 3 8 inch 1 27 cm to 0 96 cm reducer for a connection Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections Open the shutoff valve in the gas supply line Test all connections by brushing on a soapy water solution NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME Connect the exhaust duct to outside exhaust system Use duct tape to seal all joints With the dryer in its
13. y el aluminio que puede causar cortacircuitos cableado y tomacorriente apropiado es un cord n el ctrico equipado con conductores de cobre con un tomacorriente con conductores de cobre NOTA Las secadoras que operan con un suministro de energ a de 208 voltios usar n m s tiempo de secado que aquellas que operan con un suministro de energ a de 240 voltios REQUERIMIENTOS PARA LA PUESTA A TIERRA Secadoras EL CTRICAS No canadienses Laconexi n indebida del conductor de puesta a tierra del equipo puede ocasionar un riesgo de choque el ctrico Consulte con un electricista profesional si tiene alguna duda respecto a la puesta a tierra correcta del artefacto Para una secadora puesta a tierra con cord n el ctrico 1 La secadora DEBE ser puesta a tierra En caso de malfuncionamiento o falla la puesta a tierra reducir el riesgo de choque el ctrico proporcionando un trayecto de menor resistencia a la corriente el ctrica 2 Sisusecadoraest equipada con un cord n el ctrico que posee un conductor de puesta a tierra del equipo y un enchufe de puesta a tierra dicho enchufe DEBE ser conectado a un tomacorriente adecuado debidamente instalado y puesto a tierra de acuerdo con todos los c digos y reglamentos locales Sitiene alguna duda consulte a un electricista profesional No modifique el enchufe proporcionado la aplicaci n Para una secadora conectada permanentemente 1 La secadora DEBE ser conectada a un sistema de c
14. 60 Hz Alternating Current POWER SUPPLY CORD KIT 3 wire the dryer MUST employ a 3 conductor power supply cord NEMA 10 30 type SRDT rated at 240 volt AC minimum 30 amp with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS FOR A 3 WIRE SYSTEM 4 wire The dryer MUST employ a 4 conductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS FOR A 4 WIRE SYSTEM Canada 4 wire power supply cord is installed on dryer WARNING Risk of Shock Appliance grounded to neutral conductor through a link Grounding through the neutral link is prohibited for 1 New branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes do not permit grounding through the neutral 1 disconnect the link from the neutral 2 use grounding terminal or lead to ground appliance in accordance with local codes and 3 connect neutral terminal or lead to branch circuit neutral in usual manner if the appliance is to be connected by means of a cord kit use 4 conductor cord for this purpose USE COPPER CONDUCTOR ONLY OUTLET RECEPTACLE NEMA 10 30R receptacle to be located so the power supply cord is accessible when the dryer is i
15. ISAGRA INSTALACION ELECTRICA TODAS as secadoras ELECTRICAS Los siguientes requerimientos son especificos para el funcionamiento correcto y seguro de su secadora El incumplimiento de estas instrucciones puede causar prolongaci n excesiva del tiempo de secado y riesgos de incendio FN Este artefacto DEBE ser puesto a tierra de manera correcta Si la secadora no est debidamente puesta a tierra se puede producir un choque el ctrico Siga las instrucciones indicadas en este manual para la puesta a tierra en forma correcta V X No use un cord n de extensi n con esta secadora Algunos cordones de extensi n no pueden soportar la cantidad de corriente el ctrica que utiliza esta secadora y pueden fundirse creando un peligro de choque el ctrico y o incendio Ubique la secadora de manera que el cord n el ctrico llegue hasta el tomacorriente que se va ausar dejando un poco de holgura para el cord n Consulte los requerimientos de instalaci n preliminares indicados en este manual para el cord n el ctrico que debe ser adquirido V Se debe instalar un anclaje aprobado por el U L para el cord n el ctrico Sinoseutiliza un anclaje para sujetar el cord n el ctrico ste puede salirse de la secadora y cortarse con cualquier movimiento resultando en un choque el ctrico VN No utilice un tomacorriente con cables de aluminio con un cord n y un enchufe de cobre o viceversa Se produce una reacci n qu mica entre el cobre
16. Kenmore Gas amp Electric Dryer Secadora a gas y el ctrica P N 134199600H 0804 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com CONTENTS Pre Imstallation REQUIFEMIENING 2 cae A PS 3 Exhaust System a Us e deanuas 3 4 Gas lee eC SINE I m m 4 5 ON Or YOU 5 BO eile DIMENSION PNE Em 6 Moode Home WAS 7 HP a o o A 7 REVES POD MINO Q 8 ia Mi II EUP 9 e reisen ei aiii REPE 9 Mde cua mo cu E 9 Electrical Connections m 10 Gas C O ee ee ee eer reer MM ee rete ae ee ee eee eee 10 General gus RR e M 10 Sel etii ateos 10 crie m ETT 11 20 SAFETY INSTRUCTIONS Clothes dryer installation and service must be performed by a qualified installer service agency or the gas supplier Install the clothes dryer according to the manufacturer s instructions and local codes Before beginning installation carefully read these instructions This will simplify the installation and ensure the dryer is installed correctly and safely Leave these instructions near the Dryer after install
17. ST be exhausted outdoors 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation 160 SQ IN 387 1 SQ CM 1 1 387 150 CM 15 38 1 cm Y__ CLOSET DOOR 1 2 54 cm o NOR 0 0 cm NOTE Under counter and stack models 0 inches 0 cm for sides rear o 0 0 cm 1 2 54 cm i 0 0 0 0 cm UNDER COUNTER INSTALLATION If an under counter installation is desired the dryer MUST have a top sheet kit installed P N 131629100 Kit 15 available from an authorized parts distributor Custom sized countertop is required UNDER COUNTER amp STACK MODELS TOP CONSOLE MODELS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS 26 7 8 68 3 cm ELECTRIC CONNECTION UNDER COUNTER 34 5 8 87 9 cm 2 9 16 6 5 cm 13 1 2 34 4 cm 36 C 91 5 cm 3 8 0 96 cm DIA Ll 3 8 0 96 cm DIA 8 A GAS PIPE 4 2 54cm 05m GAS PIPE 1 2 54cm REAR VIEW REAR VIEW 47 1 2 120 7 cm 47 1 2 120 7 cm DOOR OPEN 90 DOOR OPEN 90 43 8 m 11 1 cm 4 4 3 8 11 1 cm PA OPTIONAL Dl VENT KNOCKOUT va 1 97 T Ll 68 6 cm 27 9 68 6
18. VERTENCIA Riesgo de explosion No instale la secadora donde se guarda gasolina u otros materiales inflamables Si la secadora se instala en un garage ella debe estar por lo menos 18 pulgadas 45 7 cm por encima del suelo El incumplimiento puede resultar en la muerte explosi n incendio o quemaduras LARGO M XIMO del Conducto Met lico Rigido de 4 10 2 cm de Di metro TIPO DE CAPERUZA DE SALIDA Preferido 60 0328m 20 pies 12 19 32 pies 975 m 16 pies 487 m 48 pies 14 63 m LARGO M XIMO del Conducto Met lico Flexible de 4 10 2 cm de Di metro TIPO DE CAPERUZA DE SALIDA Preferido 30 pies 9 14 m 18 pies 5 49 m 22 pies 6 71 m 14 pies 4 27 m 14 pies 4 27 m 10 pies 3 05 m NO RECOMENDADO INCORRECTO ZER Vp 3 INSTALE LOS ACCESORIOS MACHOS EN LA DIRECCI N CORRECTA Paralasinstalaci nes cuyas sistema de exhaustaci n nose encuentre en el diagrama se puede utilizar el metodo a continuaci n para determinar si el sistema de exhaustaci n es apropiado 1 Conecte un man metro a tubo inclinado o digital entre la secadora y el uni n de exhaustaci n de la secadora 2 Ponga el contador de tiempo de la secadora y la temperatura a aire fr o enfiriamiento y la secadora en la posici n de marcha 3 Leala medida indicada en el man metro 4 La baja presi n NO DEBE exceder 0 75 pulgada de la columna de agua Si la baja presi n es inferior a 0 75 de la co
19. a casa m viles cerrada el ducto de escape DEBE terminar fuera del recinto con el extremo final asegurado en contra de la estructura de la casa m vil Alinstalar una secadora de gas en una casa movil hay que instalar una provisi n de aire fresco suplementario La provisi n tiene que ser m s grande que dos veces el espacio del escape de la secadora Esta secadora DEBE asegurarse al piso El juego para instalaci n en la casa m vil es el No 169840 y lo puede adquirir con su distribuidor Vealas paginas 2 y 3 para otros requ sitos importantes de ventilaci n La instalaci n DEBE cumplir con las est ndares aplicables de la Manufactured Home Construction amp Safety Standard Est ndares de Seguridad y Construcci n de Casas Prefabricadas T tulo 24 CFR Parte 32 80 del Reglamento Federal o cuando dichos est ndares no sean aplicables se deben complir con los est ndares de la American National Standard for Mobile Homes Est ndares Nacionales Americanas para Viviendas M viles En Canad se aplica el Est ndar CSA Z240 YEN Esta secadora ha sido dise ada PARA USO DOMESTICO solamente de acuerdo con la norma ANSIZ 21 5 1 Correct Incorrect 16 DESEMBALAJE 1 Utilizando las cuatro esquineras de embarque de la caja de cart n dos a cada lado coloque cuidadosamente la secadora sobre el costado izquierdo y saque la base de espuma de embarque 1 para evi
20. ableado met lico permanente puesto a tierra o se debe instalar un conductor de puesta atierra de equipo junto con los conductores del circuito y conectarse al borne de puesta a tierra del equipo O al cable del artefacto Secadoras EL CTRICAS canadienses La conexi n indebida del conductor de puesta a tierra delequipo puede ocasionar un riesgo de choque el ctrico Consulte con un electricista profesional si tiene alguna duda respecto a la puesta a tierra correcta del artefacto Para una secadora puesta a tierra con cord n el ctrico 1 La secadora DEBE ser puesta a tierra En caso de malfuncionamiento o falla la puesta a tierra reducir el riesgo de choque el ctrico proporcionando un trayecto de menor resistencia a la corriente el ctrica Sisusecadora est equipada con un cord n el ctrico que posee un conductor de puesta a tierra del equipo y un enchufe de puesta a tierra dicho enchufe DEBE ser conectado a un tomacorriente adecuado debidamente instalado y puesto a tierra de acuerdo con todos los c digos y reglamentos locales Si tiene alguna duda consulte a un electricista profesional No modifique el enchufe proporcionado la aplicaci n TODAS las secadoras a GAS Esta secadora est equipada con un enchufe de tres espigas de puesta atierra para protecci n en contra de choques el ctricos y debe ser conectada directamenta en un recept culo para tres espigas el cual debe estar puesto a tierra No corte ni el
21. an cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase drying times Do not screen the exhaust ends of the vent system nor use any screws rivets or other fastening means that extend into the duct and catch lint to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with duct tape All male duct pipe fittings MUST be installed downstream with the flow of air NANO Explosion hazard Do not install the dryer where gasoline or other flammables are kept or stored f the dryer is installed in a garage it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death explosion fire or burns MAXIMUM LENGTH of 4 10 2 cm Dia Rigid Metal Duct VENT HOOD TYPE Preferred Louvered Number of 90 Turns 10 2 cm o 960ft i amp 28m 48ft 1463m MAXIMUM LENGTH of 4 10 2 cm Dia Flexible Metal Duct VENT HOOD TYPE Preferred NET 10 2 cm 0 30ft 914m 18ft 5 49m 1 2ft 671m Ft 4 27 m a 10 ft 3 05 m 1 3 NOT RECOMMENDED CORRECT ZEL 4 I INSTALL MALE FITTINGS IN CORRECT DIRECTION In installations where the exhaust system is not described in the charts
22. ation for future reference NOTE The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada the Canadian electrical code C22 1 part 1 NOTE The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI 2223 1 or in Canada CAN ACG B149 1 2000 NOTE The Dryer is designed under ANSIZ 21 5 1 or ANSI UL 2158 CAN CSA C22 2 No 112 latest editions for HOME USE only This Dryer is not recommended for commercial applications such as restaurants or beauty salons etc Your safety and the safety of others is very important We have provided many important safety messages in the Use amp Care Guide Operating Instructions Installation Instructions and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hurt you or others All safety messages will be preceded by the safety alert symbol and the word DANGER or WARNING These words mean DANG E R You will be killed or seriously injured if you don t follow instructions 4h WARNING DEM E You can be killed or seriously injured if you don t follow instructions All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed A WARNING RISK
23. ck by a path of least resistance for electrical current 2 Since your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician Do not modify plug provided with the appliance ALL GAS Dryers 1 The dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from the plug ELECTRICAL CONNECTIONS FOR 3 WIRE SYSTEM ELECTRICAL CONNECTIONS FOR 4 WIRE SYSTEM Non Canadian ELECTRIC Dryer Won Canadian ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time GREEN GROUND SCREW NEUTRAL Q SILVER TERMINAL GROUND A Sel m Mh WIRE TIGHTEN NUT TO THESE THREADS MOUNTING BRACKET POWER CORD 3 Thread a U L approved 30 amp power cord NEMA 10 30 Type SRDT through the strain relief 4 Attach the power cord neutral center wire conductor to the silver colored center termina
24. e la caperuza de salida y el piso o entre cualquier otra obstrucci n Los siguientes requerimientos son espec ficos para el funcionamiento correcto y seguro de su secadora El incumplimiento de estas instrucciones puede causar prolongaci n excesiva del tiempo de secado y riesgos de incendio No instale la Secadora con materiales de ventilaci n pl sticos flexibles En Canad y los Estados Unidos si el conducto es de metal tipo hoja de aluminio ste debe ser de un tipo espec fico identificado por el fabricante recomendado para el uso con Secadoras y en los Estados Unidos debe adem s cumplir con la norma UL 2158A Los materiales de ventilaci n flexibles se pueden colapsar o apachurrar f cilmente y atrapar pelusa Estas condiciones obstruir n la circulaci n de aire de la Secadora de ropa y aumentar n riesgo de incendio Si su sistema de escape actual tiene ductos de pl stico o de laminas met licas delgadas reempl celo con un ducto met lico r gido o flexible Aseg rese de que los ductos existentes no tengan pelusas antes de instalar el ducto de la secadora SI Q CORRECTO INCORRECTO Riesgo de incendio Lasecadora debe ser ventilada al exterior de la vivienda No ventile la secadora a una chimenea pared techo tico pasajes entre pisos o cualquier espacio oculto de la vivienda Las secadoras de ropa producen pelusa combustible Si no se ventila la secadora al exterior algunas pelusa
25. final position adjust one or more of the legs until the dryer is resting solid on all four legs Place a level on top of the dryer THE DRYER MUST BE LEVEL AND RESTING SOLID ON ALL FOUR LEGS 4 Plug the power cord into a grounded outlet NOTE Check to ensure the power is off at circuit breaker fuse box before plugging the power cord into the outlet 5 Turn on the power at the circuit breaker fuse box NOUN Before operating the dryer make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer to OFF and wait 5 minutes before making another attempt to light If your dryer does not operate please review the Avoid Service Checklist located in your Owner s Guide before calling for service Place these instructions in a location near the dryer for future reference To stack your dryer on a compatible washer call your local dealer to find your local distributor to purchase a stacking kit accessory part number 5303937141 NOTE A wiring diagra
26. imine la espiga de puesta a tierra de este enchufe 17 CONEXIONES ELECTRICAS PARA UN SISTEMA TRIFILAR Secadoras ELECTRICAS No canadienses 1 Saque los tornillos que sujetan la cubierta de acceso del tablero de bornes y el soporte de montaje del anclaje del cord n situado en la esquina superior de la parte trasera de la secadora 2 Instale un anclaje de cable aprobado por el U L en el orificio de entrada del cord n el ctrico en el soporte de montaje Luego apriete la tuerca con los dedos solamente TORNILLO VERDE DE PUESTA A TIERRA BORNE PLATEADO ARO do els q ES CABLE DE PUESTA A TIERRA NEUTRAL r Ww il E HE TUERCA ATORNILLE LA TUERCA EN ESTAS ROSCAS SOPORTE DE MONTAJE DEL ANCLAJE DE CABLE CORDON ELECTRICO 3 Inserte un cordon el ctrico de 30 amp NEMA 10 30 Tipo SRDT aprobado por el U L a trav s del anclaje de cable 4 Conecte el conductor neutro del cord n el ctrico cable central al borne central plateado del tablero de bornes Apriete firmemente el tornillo 5 Conecte los dos conductores externos restantes del cord n el ctrico a los bornes bronceados externos del tablero de bornes Apriete firmemente los tornillos No doble en forma pronunciada niengarce los cables conductores en las conexiones 6 Coloque nuevamente el soporte de montaje del anclaje de cable en la parte trasera de la secadora con dos tornillos Apriete firmemente
27. l stico pueden convertirse en c maras sin aire y causar asfixia Elimine todos los materiales poni ndolos en la basura o fuera del alcance de los ni os Las instrucciones incluidas en este manual y en el resto de la documentaci n que se entrega con la secadora no pueden cubrir todas las situaciones o condiciones posibles que puedan presentarse Por lo tanto se DEBEN seguir pr cticas seguras y tener cuidado cuando se instala cualquier artefacto dom stico Notes
28. l on the terminal block Tighten the screw securely 5 Attach the remaining two power cord outer conductors to the outer brass colored terminals on the terminal block Tighten both screws securely Yl Do not make a sharp bend or crimp wiring conductor at connections 6 Reattach the strain relief mounting bracket to the back of the dryer with two screws Tighten screws securely 7 Tighten the screws securing the cord restraint firmly against the power cord 8 Tighten the strain relief nut securely so that the strain relief does not turn 9 Reinstall the terminal block cover 1 10 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner Install a U L approved strain relief in the entry hole of the mounting bracket Finger tighten the nut only at this time GREEN GREEN POWERCORD GROUND GROUND WIRE SCREW SILVER TERMINAL AV X jl M sa TIGHTEN NUT TO THESE THREADS Remove the ground wire from the green ground screw located above the terminal block TYPICAL 4 CONDUCTOR BLACK WHITE TYPICAL 4 RED 240V CONDUCTOR GREEN 30 AMP NEMA 14 30 TYPE SRDT OR Thread a U L approved 30 amp power cord NEMA 14 30 type ST or SRDT through the strain relief Attach the green power cord ground wire to the cabinet with the green ground screw Attach the white neutral power cord conductor
29. la secadora se enciende por primera vez el interruptor de seguridad apagar el quemador Si sto sucede gire el contador de tiempo a la posici n OFF apagado y espere 5 minutos antes de intentar encender la secadora nuevamente 19 7 Si su secadora no funciona consulte la secci n Lista de Control de Aver as que se encuentra en su Manual del Usuario antes de llamar para obtener servicio 8 Conserve estas instrucciones cerca de la secadora para referencia futura 9 Paraapilarsu Secador en una Lavadora compatible llame a su distribuidor local para encontrar su distribuidor local y comprar el n mero de parte 5303937141 accesorio de montaje NOTA Dentro de la consola de la secadora o debajo del panel superior se encuentra un diagrama del cableado PIEZAS DE RECAMBIO Si necesita piezas de recambio para su secadora llame al n mero gratis de Sears Piezas y Servicio 1 800 366 PART 1 800 366 7278 Cuando los controles marque todos los cables con etiquetas antes de desconectarlos Cualquier error de cableado puede causar una operaci n inadecuada y peligrosa Aseg rese de que la secadora funcione adecuadamente despu s de repararla ADVERTENCIA Destruya la caja de cart n las bolsas de pl stico y la banda met lica despu s de haber desempacado el centro de lavander a Los ni os pueden ponerse a jugar con ellos Las cajas de cart n cubiertas con alfombras colchas o pedazos de p
30. los tornillos 7 Apriete firmemente los tornillos del anclaje de cable contra el cord n el ctrico 8 Apriete la tuerca del anclaje de cable a fin de que el anclaje no gire 9 Coloque nuevamente la cubierta del tablero de bornes CONEXI NES EL CTRICAS PARA UN SISTEMA TETRAFILAR Secadoras ELECTRICAS No canadienses 1 Saquelostornillos que sujetan la cubierta de acceso del tablero de bornesy el soporte de montaje del anclaje de cable situado en la esquina superior en la parte trasera de la secadora 2 Instaleun anclaje de cable aprobado por el U L en el orificio deentrada del cord n el ctrico en el soporte de montaje Luego apriete la tuerca con los dedos solamente TORNILLO VERDE CONDUCTOR VERDE DE DE PUESTA CORD N EL CTRICO A TIERRA BORNE PLATEADO TABLERO DE BORNES CABLE DE PUESTA A TIERRA NEUTRA e ATORNILLE LA BLANCO TUERCA EN ESTAS ROSCAS DE CABLE EL CTRICO 3 Desconecte el cable de puesta a tierra neutral del tornillo verde de puesta a tierra situado en la parte superior del tablero de bornes 4 Inserte un cord n el ctrico tetrafilar de 30 amp NEMA 10 30 Tipo ST o SRDT aprobado por el U L a trav s del anclaje de cable TOMACORRIENTE TETRAFILAR TIPICO 240 V NEGRO NEUTRO BLANCO CORD N EL CTRICO 240 V ROJO TETRAFILAR T PICO PUESTA A TIERRA VERDE CORD N EL CTRICO DE 30 AMP NEMA 14 30 TIPO SRDT O ST 5 Conecte el cable verde de puesta a tier
31. lumna de agua el sistema es aceptable Si la lectura indica una presi n superior a 0 75 de la columna de agua la capacidad del circuito es insuficiente y la instalaci n es inaceptable Aungue un sistema vertical sea aceptable algunas circunstancias atenuantes pueden afectar el funcionamiento de la secadora e Sedebeutilizar solamente conductos metalicos rigidos e Unasalida del sistema vertical en el techo puede exponerle a un corriente de aire descendente y disminuir as su capacidad de exhaustaci n e aislante que debe atravesar el sistema puede causar condensaci n y disminuir as la capacidad de exhaustaci n del sistema e acapacidad de exhaustaci n de un sistema de exhaustaci n comprimido o ondulado puede disminuirse El sistema de exhaustaci n debe de ser inspeccionado y limpiado por lo menos cada 18 meses de uso normal Cuanto m s la secadora est utilizada m s debe verificar el buen funcionamiento del sistema de exhaustaci n y de la tapa del orificio de ventilaci n UBICACION DEL ESCAPE Todas las secadoras vienen de f brica equipadas con escape trasero Sin embargo en las secadoras el ctricas el escape puede hacerse al lado derecho o izquierdo del gabinete o en la parte inferior de la secadora En las secadoras a gas el escape del aire puede estar en el lado derecho del gabinete o en la parte inferior de la secadora El escape direccional puede efectuarse instalando un Juego de Escape P N 131456800 dis
32. m is located inside the dryer console or behind the right side panel REPLACEMENT PARTS If replacement parts are needed for your dryer call Sears Parts and Service Toll Free Number 1 800 366 PART 1 800 366 7278 Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verity proper operation after servicing Destroy the carton and plastic bags after the dryer is unpacked Children might use them for play Cartons covered with rugs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good sate practice and caution MUST be applied when installing operating and maintaining any appliance Tabla de Materias Requerimientos de instalaci n Suse Oo o TT 12 sal a 12 Requerimientos sistema 12 13 Requerimientos de ERE ES Ubica don desu SCA c RP QE ETT 14 Dimensiones etiegaseheereee ace 15 NStala ci n E WO CS m 16 nn A e A 16 16 MA 17 Requerimientos para la puesta T
33. n the installed position Canada NEMA 14 30R receptacle NEMA 10 NEMA 14 30R GAS Dryer CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximum time delay fuse or circuit breaker POWER SUPPLY 3 wire 120 volt single phase 60 Hz Alternating Current POWER SUPPLY CORD The dryer is equipped with a 120 volt 3 wire power cord NOTE Do not under any circumstances remove grounding prong from plug GROUNDING PRONG 3 EXHAUST SYSTEM REQUIREMENTS Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation When the dryer stops the dampers automatically close to prevent drafts and the entrance of insects and rodents To avoid restricting the outlet maintain a minimum of 12 inches 30 5 cm clearance between the vent hood and the ground or any other obstruction WANING The following are specific requirements for proper and safe operation of your dryer Failure to follow these instructions can create excessive drying times and fire hazards Do not install a clothes dryer with flexible plastic venting materials f your present system is made up of plastic duct or metal foil duct replace it with a rigid or semi rigid metal duct In Canada and the United States if metal foil type duct is installed it must be of a specific type identified by the appliance manufac
34. on Canadian ELECTRIC Dryer A DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician Do not modify plug provided with the appliance For a permanently connected dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical sho
35. ponible a trav s de su distribuidor de repuestos Siga las instrucciones que se suministran con el juego DIMENSIONES PARA LA UBICACI N DEL DUCTO DE ESCAPE IGUAL QUE EL OTRO LADO A 5 7 8 p 15 cm 13 1 2 34 cm REQUERIMIENTOS DEL SUMINISTRO DE GAS ADVERTENCIA Reemplace la tuber a de conexi n de cobre que no est recubrida con pl stico El lat n inoxidable o recubrido con pl stico DEBE SER utilizado 1 Lainstalaci n DEBE hacerse cumplir con los c digos locales o en ausencia de los mismos de acuerdo con los estandares del National Fuel Gas Code C digo Nacional para Gases Combustibles ANSI Z223 1 la ltima editi n Para Canad el Estandar CAN CGA B149 que est en vigor 2 La tuber a de alimentaci n de gas debe ser de 1 2 pulgada 1 27 cm de di metro 3 Siesta permitido por los c digos locales se puede usar tuber a de metal para conectar su secadora a la l nea de suministro de gas La tuber a DEBE ser fabricada de acero inoxidable o cobre recubierto de pl stico 4 Latuber a de alimentaci n de gas DEBE tener una llave de cierre individual 5 Una toma de 1 8 de pulgada 0 32 cm N P T accesible para conexi n del man metro de prueba DEBE ser instalada inmediatamente aguas arriba de la conexi n de la tuber a de alimentaci n de gas a la secadora 6 La secadora DEBE ser desconectada del sistema de tuber as de alimentaci n de gas durante cualquier ensayo de presi n
36. ra del cord n el ctrico al gabinete mediante el tornillo verde de puesta a tierra 6 Conecteel conductor blanco neutro del cord n el ctrico y el cable de puesta a tierra neutro del mazo de cables de la secadora al borne plateado central del tablero de bornes 7 Conectelos conductores rojo y negro del cord n el ctrico a los bornes bronceados externos del tablero de bornes No doble en forma pronunciada ni engarce los cables conductores en las conexi nes 8 Apriete firmemente los tornillos del anclaje de cable contra el cord n el ctrico 9 Aprietelatuerca del anclaje de cable a fin de que el anclaje no gire 10 Coloque nuevamente la cubierta del tablero de bornes 18 INSTALACION 1 CONEXION DEL GAS Secadoras a gas solamente a Saque la tapa de embarque de la tuber a de gas de la secadora situada en la parte trasera NOTA NO conecte la secadora al suministro de propano sin primeroinstalar el juego de conversi n a propano El juego de conversi n a propano debe ser instalado por un t cnico de gas calificado b Conecte una tuber a semir gida de 1 2 1 27 cm D I o una tuber a aprobada desde la l nea de suministro de gas ala tuber a de 3 8 0 96 cm ubicada en la parte trasera de la secadora Utilice un reductor de 1 2 1 27 cm a 3 8 0 96 cm para la conexi n Aplique un sellador de roscas de uso aprobado resistente a la corrosi n de los gases licuados en todas las uniones de la tuber a
37. ryer MUST be isolated trom the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa LOCATION OF YOUR DRYER DO NOT INSTALL YOUR DRYER 1 In an area exposed to dripping water or outside weather conditions 2 In an area where it will come in contact with curtains drapes or anything that will obstruct the flow of combustion and ventilation air 3 On carpet Floor MUST be solid with a maximum slope of 1 inch 2 54 cm INSTALLATION IN RECESS OR CLOSET 1 A dryer installed in a bedroom bathroom recess or closet MUST be exhausted outdoors 2 No other fuel burning appliance shall be installed in the same closet as the Gas dryer 3 Your dryer needs the space around it for proper ventilation DO NOT install your dryer in a closet with a solid door 4 A minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES Inches cm SIDES REAR TOP FRONT Alcove 0 0 cm 0 0 Closet 0 0cm 0 0 1 2 54 cm Closet door ventilation required 2 louvered openings each 60 square inches 387 square centimeters 3 inches 7 6 cm from bottom and top of door This dryer MU
38. s finas se acumular n en el rea de lavander a La acumulaci n de pelusa en cualquier rea de la vivienda puede constituir un peligro sanitario y un riesgo de incendio La secadora debe estar conectada a un sistema de escape que termine en el exterior de la vivienda Inspeccione la abertura escape al exterior con frecuencia y elimine cualquier acumulaci n de pelusa en tal abertura y en el rea que la rodea No permita que los materiales combustibles por ejemplo la ropa cortinas cortinajes papel tengan contacto con los ductos VW Excederla longitud del conducto rigido o los n meros de codos permitidos en los diagramas LARGO MAXIMO puede disminuir la capacidad de exhaustaci n del sistema Obstruir el conducto puede provocar peligro de incendio as como aumentar el tiempo de secado No obstruya los extremos tubo de ventilacion ni utilice tornillos remaches u otros medios de fijaci n que puedan obstruir el conducto y atrapar pelusa Las pelusas podr an quedar atrapadas en los filtros en los tornillos o en los remaches lo cual obstruir a el sistema de escape y crear a un riesgo de incendio as como tambi n prolongar a el tiempo de secado Use una caperuza de salida adecuada para el extremo del ducto que salga al exterior de la vivienda y selle todas las juntas con cinta adhesiva para ductos Todos los accesorios de tuber a machos DEBEN ser instalados aguas abajo del flujo de aire 12 AV AD
39. sario proveer aberturas para el aire Una puerta apersianada con aberturas para el aire en todo el largo de la puerta es aceptable DESPEJES M NIMOS DE INSTALACI N Pulgadas PARTE PARTE PARTE DELANTERA LADOS TRASERA SUPERIOR Alcoba o encastradas 0 0 cm 0 0cm 0 0 cm 15 38 1 cm Armario 1 2 54cm 0 0 0 cm 15 38 1 cm Ventilaci n requirida en la puerta del armario dos aberturas rejilladas cada 60 pulg 387 cm 3 7 6 cm desde la parte inferior y superior de la puetra EL TUBO DEL ESCAPE DE LA SECADORA DEBE SER INSTALADO HACIA EL EXTERIOR 5 Lassiguientes ilustraci nes muestran las dimensi nes m nimas de espacio libre que debe existir para el buen funcionamiento de la secadora cuando se instala en un nicho o en un armario 1 2 54 cm 15 38 1 cm 387 1 cm Pulg PUERTA DEL ARMARIO NOTA Secadoras encastradas o superpuestas O pulgada 0 cm para los lados parte trasera y en la parte superior 014 0 0 cm 0 0 cm p 4 1 2 54 cm j 0 0 cm INSTALACI N DEBAJO DE UN MOSTRADOR Si se desea una instalaci n debajo de un mostrador ES IMPRESCINDIBLE instalar un conjunto de hoja superior en la lavadora n mero de parte 131629100 Este conjunto es disponible de un distribuidor de partes autorizado Se requiere un mostrador hecho a medida
40. sting However on electric dryers exhausting can be to the right or left side of the cabinet or the bottom of the dryer On gas dryers exhausting can be to the right side of the cabinet or the bottom of the dryer Directional exhausting can be accomplished by installing Exhaust Kit P N 131456800 available through your parts distributor Follow the instructions supplied with the kit EXHAUST DUCT LOCATING DIMENSIONS SAME AS OTHER SIDE d er 5 7 8 7 4 3 8 3 3 4 GAS SUPPLY REQUIREMENTS WARNING Replace copper connecting pipe that is not plastic coated Stainless steel or plastic coated brass MUST be used 1 Installation MUST conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI 2223 1 latest edition 2 The gas supply line should be of 1 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 4 5 A 1 8 inch 0 32 cm plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dryer 6 The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1 2 psig 3 45 kPa 7 The d
41. tar da os no use el panel de control como un medio para levantar o mover la secadora NOTA En los modelos de secadoras encastradas el panel superior puede ser removido para la instalaci n 2 Vuelva la secadora a su posici n vertical PUERTA REVERSIBLE Su secadora ha sido dise ada para que la puerta pueda ser cambiada de lado en cualquier momento sin necesidad de piezas adicionales La conversi n se hace transfiriendo las bisagras al lado opuesto del gabinete C mo cambiar la direcci n de apertura de la puerta 1 Abra la puerta de la secadora Quite los cuatro receptores del agujero de la bisagra del lado izquierdo de la apertura de la puerta Col quelos en un lugar cercano para futura instalaci n NOTA Puede que se necesite un cuchillo de pl stico para poder sacar los receptores Tenga cuidado de no rayar la pintura 2 Quite los cuatro tornillos que aseguranlas bisagras de la puerta al panel frontal de la secadora ver figura abajo MOTA Primero quite un tornillo de cada una de las bisagras Mantenga la puerta sujetada firmemente antes de quitar los dos ltimos tornillos 3 Gire la puerta 180 y vuelva a colocar las bisagras de la puerta en el panel frontal con los cuatro tornillos 4 Instale los cuatro receptores de los agujeros de las bisagras en los agujeros abiertos en el lado derecho de la apertura de la puerta QUITE LOS CUATRO TORNILLOS PRIMERO QUITE UNO DE CADA B
42. terceros son muy importantes Hemos proporcionado muchos mensajes importantes para la seguridad en las Instrucciones de Operaci n del Manual de Uso y Mantenimiento las Instrucciones de Instalaci n y en el mismo aparato Siempre lea y obedezca todos los mensajes para seguridad AR s mbolo significa alerta Este s mbolo lo alerta acerca de peligros que pueden matar o lesionar tanto a usted como a otras personas Todos los mensajes de seguridad ser n precedidos por el s mbolo de alerta para su seguridad y la palabra PELIGRO o ADVERTENCIA DANGER o WARNING Estas palabras significan PELIGRO DANGER Usted morir o resultar seriamente lesionado si no sigue las instrucciones siguientes ADVERTENCIA WARNING Usted puede morir o resultar seriamente lesionado si no sigue las instrucciones siguientes Todos los mensajes de seguridad identificar n el peligro le dir n a usted c mo reducir la posibilidad de lesi n y tambi n qu puede suceder si no se siguen las instrucciones AL ADVERTENCIA RIESGO DE INCENDIO Para su seguridad siga las instrucciones contenidas en este manual a fin de reducir a un m nimo los riesgos de incendio o explosi n o para evitar da os materiales lesiones personales o la muerte GUARDE ESTAS INSTRUCCIONES Noalmaceneni utilice gasolina u otros vapores y l quidos inflamables enla proximidad de ste o de cualquier otro artefacto el ctrico DEBE HACER SI PERCIBE OLOR A GAS No trate
43. turer as suitable for use with clothes dryers and in the United States must also comply with the Outline for Clothes Dryer Transition Duct UL standard 2158A Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire Ensure the present duct is free of any lint prior to installing dryer duct DO Correct Incorrect DO O Correct INIA Risk of Fire A clothes dryer must be exhausted outdoors Do not exhaust dryer into a chimney a wall a ceiling an attic a crawl space or any concealed space of a building A clothes dryer produces combustible lint If the dryer is not exhausted outdoors some fine lint will be expelled into the laundry area An accumulation of lint in any area of the home can create a health and fire hazard The dryer must be connected to an exhaust outdoors Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts c
44. y the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel as a means to pick up or move the dryer NOTE Onunder counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position REVERSING DOOR SWING Your dryer is designed so the door swing may be reversed at any time without additional parts Conversion is accomplished by transferring hinges to the opposite side of the cabinet To change the direction of the door opening 1 Open the dryer door Remove the four hinge hole plugs from the left side of the door opening Place nearby for future installation NOTE You may need a plastic knife to help pull out the plugs Be careful not to scratch the paint Remove the four screws that secure the door hinges to the dryer front panel see below NOTE Remove one screw from each of the two hinges first Hold the door firmly before removing the last two screws Rotate the door 180 and reinstall the door hinges to the dryer front panel with the four screws Install the four hinge hole plugs in the open screw holes on the right side of the door opening 2C d Pp p T p 4 1 pj A EY p 47 E 4 Dr y i N REMOVE 4 SCREWS ONE FROM EACH HINGE FIRST ELECTRICAL INSTALLATION ALL ELECTRIC Dryers Canadian ELECTRIC Dryer
Download Pdf Manuals
Related Search
Related Contents
FP 4 E portugiesisch051219 [U4.42.04] Macro-commande DEFI_CABLE_BP Metamorph User Guide Feuille de salle - Les Subsistances DE Bedienungsanleitung GB Operating Instructions Mode d`emploi Deutsch - Schuss Home Electronic LEGEND VALVE 108-904RVTV Use and Care Manual Samsung 713N Manual de Usuario Copyright © All rights reserved.