) PUMP ONLY for MODEL IOOO - NAPA
Contents
1. 242 provided SP Coloque la extensi n a la salida de la pistola y apriete firmemente Fig 2 a EJ Rosque la manguera de suministro a la r tula de entrada de la pistola contadora usando sellador 2100 1 Samson Corporation Swannanoa NC 28778 800 311 1047 www samsoncorporation com gSA MSN ay The meter is delivered ready for use and needs no additional attention even after a long storage period If the display is not turned on or the low battery indication 2 appears in the display see Replacing batteries The meter has two totalizer registers incorporated one resettable 4 and another Naa non resettable 5 To bring up the resettable total register press the reset button 3 If the reset button is pressed again immediately the resettable total register is set to zero If not after a few seconds the non resettable total register will appear NOTE The reset button 3 must be pressed prior each delivery to clear the partial reading 1 El contador est suministrado listo para usar y no necesita manipulaci n alguna a n despu s de un largo tiempo de almacenaje Si la pantalla no est encendida o el indicador de baja tensi n 2 se muestra en la pantalla ver Sustituci n de pilas El contador tiene incorporado dos totalizadores uno con posibilidad de puesta a cero y otro sin esta posibilidad Para visualizar la cantidad acumulada en el totalizador con posibilidad de pue
2. PUMP ONLY for MODEL 000 FARI Lavi 1000 Piston Rod Bushing Packing seal Pump head Suction tube Model DG 20 Suction tube Model DG 50 E Washer Valve washer Piston Rod nut Valve Assy Fixing tube Wing screw Drum adaptor Rivet Linkage Lever Grip Handle 2100 SERIES ELECTRONIC DIGITAL METER CONTADOR ELECTRONICO SERIE 2100 Technical service guide and spare parts listing a a a mera a Gu a de servicio t cnico y recambios SAMIS 3N ear e e g Samson Corp Swannanoa NC USA Part N9 C d 2100 SERIES Description Descripci n Oval gear type Hose end meter In line meter with electronic LCD display for Lubricants Anti Freeze and WW Fluid The Hose end meter includes a progressive opening control valve for precise control of oil delivery a ball bearing inlet swivel with an extra large filter and an outlet hose with non drip tip Pistola contadora Contador en l nea de engranajes ovales y registrador electr nico para lubricantes y anti congelante La pistola contadora incluye una v lvula con apertura progresiva para un mejor control del caudal de suministro r tula de entrada con filtro y extensi n con boquilla anti goteo Installation Instalaci n E 1 Install the outlet extension to the outlet thread of the meter and tighten it well fig 2 2 Thread the dispensing hose to the inlet swivel of the hose end meter using Loctite
3. e Presi n m nima de rotura 2000 PSI 140 bar Delivery range Caudal Ya 5 GPM 1 20 l min Max Pressure drop P rdida de carga 18 PSI 1 25 bar Temperature range Temperatura 320F 40 C 0 C 40 C Max min fluid viscosity Max min viscosidad de fluido 5000 5 mPa s Accuracy unadjusted Precision sin ajuste 1 Weight Peso 3 5 LBS 1 6 kg Spare parts Recambios Pos Part N Description Descripci n Pos Part N Description Descripci n 1 1127 Swivel R tula 11 942104 Washer Arandela 2 836302 Spring Muelle 12 946068 O ring Junta t rica 3 736608 Valve holder Porta valvula 13 736606 Cam Eje 4 836500 Valve Valvula 14 946083 O ring Junta t rica 5 736607 Sleeve Empujador 15 2100 Meter Contador 6 736106 Body Cuerpo 16 836504 Meter protection Protecci n contador 7 736102 Trigger Gatillo 17 1128 Outlet hose Extensi n 8 Screw Tornillo 18 946014 Oring Junta t rica 9 Washer Arandela 19 836404 Filter Filtro 10 940102 Screw Tornillo 1 13 736625 Replacement Montaje de la 18 19 Handle Assembly pistola del reemplazo 2100 4 Samson Corporation Swannanoa NC 28778 12800 311 1047 www samsoncorporation com
4. ieza del contador Retirar la cubierta inferior del contador 1 2 3 4 Retirar los engranajes ovales Limpiar la c mara de medici n y los engranajes cuidadosamente utilizando un cepillo suave Volver a colocar los engranajes la junta y la tapa inferior como muestra la figura 6 Trouble shooting Anomal as y sus soluciones Symptom Possible Causes Solution METER Faded display Weak batteries Replace the batteries No reading in the display Display Blank Dead batteries Replace the batteries Meter has not been reset after replacement battery Press the reset key The meter is not accurate Wrong calibration factor Calibrate the meter Flow rate is outside the working flow range Increase or decrease the flow rate The display is on but the meter does not work Gears placed incorrectly after cleaning the measuring chamber Place the gears in the right position Reduced flow Clogged inlet screen Clean the inlet screen Obstructed gears Clean the measuring chamber GUN Oil leaking in closed position Contaminated valve seat or damaged valve Clean the valve seat and if necessary replace damaged parts Oil leaking through trigger cam Damaged O rings Replace O rings S ntoma Posibles causas Soluci n CONTADOR Lectura borrosa o poco clara Bater as gastadas Cambiar las bater as El display n
5. o muestra ninguna se al Bater as gastadas Cambiar las bater as No se realiz la puesta a cero despu s de cambiar las bater as Presionar el bot n puesta a cero Fallos en la precisi n del contador Factor de calibraci n err nea Calibrar el contador correctamente El caudal suministrado est fuera del rango de caudales Ajustar el caudal de fluido dentro del rango de caudales del contador El contador no cuenta aunque el display est encendido Los engranajes est n mal colocados Verifique que los engranajes est n en la posici n Caudal reducido El filtro de entrada opcional est obstruido Limpiar el filtro de entrada Los engranajes est n obstruidos Limpiar la c mara de medici n GUN Salida de aceite en posici n cerrado V lvula gastada o impurezas en el asiento de la v lvula Limpiar el asiento de la v lvula y sustituir las piezas en caso de deterioro Fuga de aceite por el eje del gatillo Junta t rica deteriorada Sustituir la junta t rica 2100 3 Samson Corporation Swannanoa NC 28778 800 311 1047 www samsoncorporation com Technical information Informaci n t cnica Please do not calibrate the meter as it is not necessary Por favor no calibrar el contador ya que no es necesario Max Working Pressure Presi n m xima de trabajo 1000PSI 70 bar Min Rupture Pressur
6. s and the battery cover 1 Fig 5 2 Replace the old batteries with new ones 2xAAA Alkaline NOTE Always replace both batteries at the same time Confirm that the batteries are placed in their correct position 3 Reattach the battery cover 1 4 Press the reset button to turn on the meter display 1 Destornillar y retirar los tornillos y la tapa de las bater as 1 Fig 5 2 Sustituir las bater as por nuevas 2xtama o AAA alcalinas NOTA Sustituir siempre las dos pilas a la vez Asegurar que la posici n de las pilas es la correcta 3 Volver a montar la tapa de las bater as 1 4 Presionar el bot n puesta a cero para encender la pantalla 2100 2 Samson Corporation Swannanoa NC 28778 12800 311 1047 www samsoncorporation com Cleaning the measuring chamber Limpiar la c mara de medici n It is not necessary to separate the meter from the oil control gun to clean the chamber WARNING Do not open the control valve by pressing the trigger while cleaning the measuring chamber Remove the cover at the back of the meter 1 2 3 4 Remove the oval gears Clean the chamber and the gears carefully using a soft brush Replace the gears then reattach the cover as shown in figure 6 No es necesario separar el contador de la pistola de control aceite para limpiarlo ATENCI N Ten cuidado de no abrir la pistola de control de aceite presionando el gatillo de forma accidental durante la limp
7. sta a cero presionar el bot n Reset 3 Si se vuelve a presionar este bot n inmediatamente este totalizador se pone a cero Sino despu s de algunos segundos aparecer la cantidad acumulada en el totalizador sin posibilidad de puesta a cero ATENCI N Antes de cada servicio presionar el bot n de puesta a cero 3 para inicializar el contador parcial 1 Measuring units Unidades de medici n 2 N e Gal HT NG T4 RESET rr TOTAX It is convenient to change the measuring units in the meter according to the following Qrs combinations Partial reading Total register Gal Gal Qts Gal Pts Gal L L a MM To change the measuring units press and hold the Reset and the Calibr buttons until the display appears showing Unit as in fig 4 Use the Reset button to change units and press the Calibr AS Pm button to confirm GAL Es posible cambiar las unidades de medici n del contador seg n las siguientes combinaciones Registrador parcial Totalisador Gal Gal Qts Gal Pts Gal L L Para cambiar las unidades de medici n mantener los botones Reset y Calibr presionados hasta que la pantalla aparece como en Fig 4 Utilizar el bot n Reset para elegir unidades y mantener el bot n Calibr para confirmar Replacing batteries Sustituci n de pilas E Remove the two screw