Home

OPERATOR`S MANUAL

image

Contents

1. 4 550 W Frecuencia nominal ss 60 Hz DIMENSIONES L ONU se ra ira 610 mm 24 pulg ANC nod 432 mm 17 pulg AM in 457 mm 18 pulg PESO plc taco en 47 6 kg 105 Ib Potencia nominal en marcha en vatios determinado por el est ndar de PGMA G200 FAMILIAR CESE CON EL GENERADOR Vea la figura 1 El uso seguro que este producto requiere la comprensi n de la informaci n impresa en el producto y en el manual del operador as como ciertos conocimientos sobre el proyecto a realizar Antes de usar este producto familiaricese con todas las caracter sticas de funcionamiento y normas de seguridad DISYUNTOR Los disyuntors se proporcionan para proteger el generator contra sobrecarga el ctrica El disyuntor de circuito puede restaurarse con el bot n de reajuste del disyuntor FILTRO DE AIRE El filtro de aire ayuda a limitar la cantidad de tierra y polvo que penetra a la unidad durante el funcionamiento PALANCA DEL ANEGADOR La palanca del anegador se emplea al arrancar el motor PANTALLA DIGITAL La pantalla digital muestra el voltaje de CA de salida la frecuencia cu nto tiempo hace que el motor est en marcha desde la ltima vez que se lo encendi y la cantidad total de horas de uso de la unidad TANQUE DE COMBUSTIBLE El tanque de combustible tiene una capacidad de 15 1 L 4 galones V LVULA DE COMBUSTIBLE Le d bit de carburant du r servoir de carburant vers le moteur se ferme et s
2. Utilice la unidad en un area bien ventilada e iluminada aislada de las reas de trabajo para evitar la interferencia del ruido Si se utiliza el generador en condiciones h medas puede causarse una electrocuci n Mantenga seca la unidad Mantenga el generador a una distancia m nima de 910 mm 3 pies de todo tipo de material combustible No utilice el generador cerca de materiales peligrosos No utilice el generador en una estaci n de abastecimiento de gasolina o gas natural No toque el silenciador ni el cilindro durante el funcionamiento de la unidad ni inmediatamente despu s est n CALIENTES y causan lesiones por quemadura No permita que se derrame el tanque del generador al abastecerlo de gasolina Ll nelo hasta una altura de 25 4 mm 1 pulg abajo del cuello del tanque de gasolina para permitir la expansi n del combustible Revise el orificio de ventilaci n del interior del tanque de combustible para ver si tiene basura No bloquee el respiradero No fume mientras abastece de gasolina el generador Apague el motor y d jelo enfriar por completo antes de agregar gasolina o lubricante al generador No retire la varilla de nivel de aceite ni la tapa del tanque del combustible mientras est funcionando el motor Preste atenci n en particular a todas las etiquetas de seguridad adheridas al generador En todo momento mantenga alos ni os a una distancia m nima de 3 m 10 pies del generador La unidad
3. When adding gas to the generator make sure the unit is sitting on a flat level surface If the engine is hot let the generator cool before adding gas ALWAYS fill the fuel tank outdoors with the machine turned off E Remove the fuel cap E Fill the fuel tank to 1 in below the top of the fuel neck m Replace and secure the fuel cap NOTE Always use unleaded gasoline with a pump octane rating of 86 or higher Never use old stale or contaminated gasoline and do not use an oil gas mixture Do not allow dirt or water into the fuel tank STARTING THE ENGINE See Figures 9 11 NOTICE On a level surface with the engine off check the lubricant level before each use of the generator NOTE If location of generator is not level the unit may not start or may shut down during operation E Unplug all loads from the generator E Turn the fuel valve to the ON position E Move the choke lever left to the START position NOTE If engine is warm or the temperature is above 50 F move the choke lever right to the RUN position NW Put the engine switch in the ON I position Pull the recoil starting grip until the engine runs a maxi mum of 6 times NOTE Do not allow the grip to snap back after starting return it gently to its original place EH Allow the engine to run for 15 30 seconds then move the choke lever right to the RUN position Page 14 English OPERATION STOPPING THE ENGINE See Figures 10 and
4. la varilla de nivel La unidad est equipada de un sensor el cual apaga autom ticamente el motor si el nivel de lubricante desciende abajo del l mite de seguridad PARACHISPAS El uso de este equipo puede producir chispas propensas a iniciar incendios cerca de vegetaci n seca Es posible que se necesite un parachispas El operador debe ponerse en A WARNING DEA o SES contacto con las agencias contra incendios locales para around dry vegetation A spark arrestor may be required The operator should contact conocer las leyes y regulaciones relacionadas con los local fire agencies for laws or regulations relating to fire prevention requirements requisitos de prevenci n de incendios A ADVERTENCIA A ei ONCE iniciar incendios cerca de vegetaci n seca Es posible que se necesite mn Aree Z pas El operador debe ponerse en contacto con las agencias contra incendios locales ADVERTENCIA ACERCA DE LA CONEXION A TIERRA para conocer las leyes y regulaciones relacionadas con los requisitos de prevenci n de incendios 940947006 01 El Reglamento Nacional de Electricidad exige que el generador est conectado a una tierra aprobada WARNING WARNING A ADVERTENCIA HOT SURFACE Product does not include ground rod or copper wire National Electric Code requires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements 940680040 02 ADVERTENCIA SUPERFICIES CALIENTE El product
5. Sistema de inducci n de aire que incluye a Tubo de entrada colector m ltiple b Limpiador de aire 3 Sistema de encendido que incluye a Buj a b Bobina de encendido 4 Conjunto del silenciador catal tico que incluye a Junta del silenciador b Colector de escape c Convertidor catal tico 5 Conjunto de la entrada de aire del c rter que incluye a Tubo de conexi n de la entrada de aire 6 Sistema de control de emisiones vol tiles del tanque de combustible que incluye a V lvulas de purga b Recept culo de carb n c Soportes de montaje del recept culo d Tapa del tanque de combustible 7 Art culos varios usados en sistemas anteriores que incluyen a Interruptores b Mangueras correas conectores y conjuntos 8 Sistema de inyecci n de aire a V lvula de impulso La garant a se ofrece de acuerdo con la Declaraci n de garant a del control de emisiones de la EPA de EE UU P gina 21 Espa ol GARANT A DECLARACI N DE GARANT A DE CONTROL DE EMISIONES DE OWT INDUSTRIES INC Y REGULACIONES FEDERALES DERECHOS Y OBLIGACIONES DEL CONSUMIDOR SEG N LA GARANTIA La Direcci n de protecci n ambiental EPA de EE UU de Medioambiente de Canad Environment Canada y OWT Industries Inc tienen el gusto de explicar la garant a del sistema de control de emisiones evaporativas de motor peque o para uso fuera de carreteras Equipo nuevos que utiliza los motores peq
6. Warm lubricant will drain quickly and more completely A WARNING Do not change engine lubricant while it is hot Accidental contact with hot engine lubricant could result in serious burns E Reinstall the oil drain plug and tighten securely Refill with lubricant following the instructions in the Checking Adding Lubricant section For amount of lubricant needed to refill see Product Specifications earlier in this manual or the accompanying engine manual if applicable NH Reinstall the oil cap dipstick NOTE Used lubricant should be disposed of atan approved disposal site See your local oil retailer for more information SPARK PLUG MAINTENANCE See Figure 16 The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check E Remove the spark plug cap EH Clean any dirt from around base of spark plug E Remove spark plug using wrench not included le Inspect spark plug for damage and clean with a wire brush before reinstalling If insulator is cracked or chipped spark plug should be replaced For replacement spark plug see Product Specifications earlier in this manual or the accompanying engine manual if applicable m Measure plug gap The correct gap is 0 028 0 031 in 0 7 0 8 mm To widen gap if necessary carefully bend the ground top electrode To lessen gap gently tap ground electrode on a hard surface WN Seat spark plug in position thread in
7. 114 m 375 pies 76 m 250 pies 5 600 152 m600pies 91 m 300 pies 61 m 200 pies 38 m 125 pies 75 900 107m 850pies 6tm 200 pies 38 m 125 pies 31 m 100 pies to 120 76m 20pies 46m 150pies 31m 100 pies 15 m 50 pies _ gt 15 1800 46m 150pies 3tm 100pies 20 m 65 pies 20 2400 53m 175pies 38m 125 pies 23 m 75 pies f o 25 3000 46 m 150 pies 81 m 100 pes 30 3600 38m 125pies 20m 65pie o so 4800 zmene CARGAS DE MOTORES EL CTRICOS Es caracter stico en el funcionamiento normal de los motores el ctricos comunes consumir durante el arranque hasta seis veces su corriente de operaci n Esta tabla puede emplearse para estimar la potencia necesaria en vatios para arrancar los motores el ctricos no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herramienta de inmediato para evitar da ar el equipo Siempre verifique los requisitos de la herramienta o aparato con la salida nominal del generador a IN El requerimiento de voltaje y frecuencia operativa de todos los equipos electr nicos debe comprobarse antes de enchufarlos a este generador Pueden ocurrir da os si el equipo no est dise ado para operar dentro de una variaci n de voltaje de 10 y una variaci n de frecuencia de 3 hz de los valores nominales que aparecen en la placa de identificaci n del generador A fin
8. 12 To stop the engine under normal operating conditions E Remove any load from the generator m Turn the fuel valve to the OFF position E Put the engine switch in the OFF position To stop the engine in an emergency situation E Put the engine switch in the OFF position A WARNING While operating and storing keep at least 3 feet of clear ance on all sides of this product including overhead Allow a minimum of 30 minutes of cool down time be fore storage Heat created by muffler and exhaust gases can be hot enough to cause serious burns and or ignite combustible objects UNDERSTANDING THE DIGITAL DISPLAY See Figure 13 The digital display shows AC voltage output frequency how long the engine has been running during the current usage period and the total number of hours the unit has been used To cycle through these displays press the select button The information type on the digital display will light in sequence to show which type of information is being displayed Hour meter The hour meter keeps track of how many hours the unit has been running during the current operation as well as the total number of hours the unit has been used AC voltage When selected the AC voltage indicator will display the generator s voltage output Frequency When selected the frequency indicator shows the generator s output frequency MOVING THE GENERATOR E Turn the engine switch OFF Disconnect any equipment t
9. a la parte inferior del bastidor coloque firmemente cu as debajo para apoyarlo NE Localice los siguientes art culos 2 Pies de soporte 4 Tuercas de bloqueo 1 4 20 4 Pernos 1 4 20 x 1 5 pulg E inserte los pernos a trav s del pie y el armaz n tal como se indica E Coloque las tuercas de bloqueo y ajuste firmemente E Repita estos pasos con el otro pie P gina 11 Espa ol ARMADO INSTALACI N DE LAS RUEDAS COLOCACI N DEL MANGO Las ruedas se proporcionan para ayudar a trasladar el Localice los siguientes art culos generador hasta la ubicaci n deseada y deben instalarse del mismo lado que el arrancador retr ctil NH Localice los siguientes art culos 2 Ruedas 2 Pernos 3 8 16 x 4 25 pulg 2 Espaciador 2 Tuercas de bloqueo 3 8 Mango 1 Perno 1 4 20 x 1 5 pulg 1 Tuerca de bloqueo 1 4 20 E Coloque el mango en el soporte del mango E Deslice el perno 1 4 20 x 1 5 mm a trav s del mango y el soporte del mango Coloque la tuerca de bloqueo y aj stela firmemente E Levante el generador del lado opuesto del arrancador retr ctil hasta la altura suficiente para obtener acceso a la parte inferior del bastidor coloque firmemente cu as debajo para apoyarlo Coloque un espaciador de rueda en el centro de sta Deslice el perno a trav s del espaciador de rueda y a A ADVERTENCIA No intente levantar la unidad por medio de los mangos Si fuese necesario izar el generador siempre hagalo por
10. aire libre y lejos de ventanas puertas y respiraderos abiertos Estas aberturas pueden atraer los gases de escape del generador Incluso si utiliza el generador correctamente el CO puede ingresar en su hogar SIEMPRE utilice una alarma de CO de pilas o con pilas de respaldo en su hogar Si comienza a sentirse descompuesto mareado o d bil luego de que el generador estuvo funcionando trasl dese adonde haya aire fresco INMEDIATAMENTE Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono ADVERTENCIA Lea y comprenda todas las instrucciones El incumplimiento de cualquiera de las instrucciones siguientes puede causar electrocuci n incendio ointoxicaci n por mon xido de carbono lo cual puede causar la muerte o lesiones graves A PELIGRO El Reglamento Nacional de Electricidad exige que el generador est conectado a una tierra aprobada Antes de utilizar la terminal de tierra consulte a un electricista calificado inspector de instalaciones el ctricas u organismo gubernamental de la localidad en lo referente a las reglas y disposiciones relacionadas con el uso deseado del generador GUARDE ESTAS INSTRUCCIONES Este manual contiene importantes instrucciones que se deben seguir durante la instalaci n y las actividades de mantenimiento del generador y las bater as No conecte la unidad al sistema el ctrico de un edificio a menos que el generador y el interruptor de transferencia se hayan instalado
11. by hand to prevent cross threading E Tighten with wrench to compress washer If spark plug is new use 1 2 turn to compress washer appropriate amount If reusing old spark plug use 1 8 to 1 4 turn for proper washer compression NOTE An improperly tightened spark plug will become very hot and could damage the engine Page 16 English MAINTENANCE CLEANING THE EXHAUST PORT AND MUFFLER Depending on the type of fuel used the type and amount of lubricant used and or your operating conditions the exhaust port and muffler may become blocked with carbon deposits If you notice a power loss with your gas powered products you may need to remove these deposits to restore perfor mance We highly recommend that only qualified service technicians perform this service SPARK ARRESTOR See Figure 17 The spark arrestor must be cleaned or replaced every 50 hours or yearly to ensure proper performance of your product Spark arrestors may be in different locations depending on the model purchased Please contact your nearest service dealer for the location of the spark arrestor for your model To clean the spark arrestor m Remove the screws securing the spark arrestor in place E Remove the spark arrestor and gently clean using a wire brush E Replace spark arrestor and secure using the screws DRAINING FUEL TANK CARBURETOR See Figures 18 19 To help prevent gum deposits in the fuel system drain the fuel from the tank and
12. correctamente y que un electricista calificado haya verificado la salida de energ a el ctrica La conexi n debe aislar la corriente del generador del servicio p blico y debe cumplir con todas las leyes y los c digos el ctricos pertinentes No permita que utilicen esta unidad ni os ni personas carentes de la debida instrucci n para su manejo No haga arrancar o funcionar el motor en un espacio confinado de edificio cerca de ventana abiertas o en otro rea sin ventilaci n donde se puedan recolectar las emanaciones de mon xido de carbono El mon xido de carbono un gas incoloro inodoro y sumamente peligroso puede causar la p rdida de la conciencia o la muerte Mantenga a todos los circunstantes ni os y animales por lo menos a 3 m 10 pies de distancia Use botas o zapatos robustos y secos No utilice la unidad estando descalzo No utilice este generador cuando se encuentre fatigado enfermo o bajo los efectos de drogas alcohol o medicamentos Mantenga todas las partes del cuerpo alejadas de toda pieza m vil y superficie caliente de la unidad No toque cables ni recept culos desprovistos de aislamiento No utilice el generador con cordones de corriente gastados deshilachados pelados o da ados de cualquier forma Antes de guardar la unidad deje que se enfr e el motor y retire el combustible de la unidad No utilice or guarde el generador en la lluvia nieve o tiempo h medo Guarde el generador en
13. de este producto se ha conferido prioridad a la seguridad al desempe o y la fiabilidad por lo cual se facilita su manejo y mantenimiento A PELIGRO CONEXION A TIERRA DEL GENERADOR Para reducir el riesgo de descarga o electrocuci n el generador debe conectarse a tierra correctamente Siempre debe utilizarse la tuerca y el terminal de conexi n a tierra del bastidor para conectar el generador a una fuente apropiada de conexi n a tierra La conexi n a tierra debe realizarse con alambre calibre N 8 Conecte el terminal del alambre de conexi n a tierra entre la arandela y la tuerca y apriete firmemente la tuerca Conecte el otro extremo del alambre firmemente a una fuente apropiada de conexi n a tierra El C digo El ctrico Nacional especifica varias maneras pr cticas para establecer una buena fuente de conexi n a tierra Si se utiliza una barra de acero o de hierro ste debe ser de 15 9 mm 5 8 pulg de di metro y si se utiliza una barra no ferrosa sta debe ser de 12 7 mm 1 2 pulg de di metro como m nimo y estar listada como material adecuado para conexi n a tierra Hinque la barra o tubo hasta una profundidad de 2 4 m 8 pies Si se encuentra roca s lida a menos de 1 2 m 4 pies de profundidad entierre la barra o tubo en una zanja Todas las herramientas el ctricas y aparatos alimentados por este generador deben conectarse apropiadamente a tierra mediante el uso de un tercer alambre o tener un dise o con
14. de la buj a E Retire los buj as con la llave no incluido E Inspeccione la buj a para ver si est da ada y limpiela con un cepillo de alambre antes de volver a instalarla Si el aislante est agrietado o desportillado debe reemplazarse la buj a Para saber cu l es la buj a de recambio correcta consulte la secci n anterior Especificaciones del producto de este manual o el manual del motor adjunto si corresponde E Mida el espacio interelectr dico La separaci n correcta es 0 7 0 8 mm 0 028 0 031 pulg Para ampliar la separaci n doble con cuidado el electrodo superior de conexi n a tierra Para angostar el espacio golpee suavemente sobre una superficie dura el electrodo de tierra M Asiente en su lugar la buj a y enr squela con la mano para evitar trasroscarla P gina 16 Espa ol MANTENIMIENTO E Apri tela con una llave para comprimir la arandela Si es nueva la buj a g rela 1 2 vuelta para comprimir al nivel adecuado la arandela Si va a volver a usar la buj a vieja g rela de 1 8 a 1 4 de vuelta para comprimir al nivel adecuado la arandela NOTA Sino se aprieta debidamente la buj a se calienta mucho y podr a da ar el motor LIMPIEZA DEL ORIFICIO DE ESCAPE Y DEL SILENCIADOR Seg n sea el tipo de combustible empleado el tipo y cantidad de lubricante empleado as como las condiciones de funcionamiento puede obstruirse el orificio de escape y el silenciador con dep sitos de carbo
15. each subsequent purchaser that the small off road engine SORE 1 has been designed built and equipped so as to conform with all applicable regulations and 2 is free from defects in materials and workmanship that cause the failure of a warranted part to conform with those regulations as may be applicable to the terms and conditions stated below a The warranty period begins on the date the engine is delivered to an ultimate purchaser or first placed into service The warranty period is two years b Subject to certain conditions and exclusions as stated below the warranty on emissions related parts is as follows 1 Any warranted part that is not scheduled for replacement as required maintenance in your Operator s Manual is warranted for the warranty period stated above If the part fails during the period of warranty coverage the part will be repaired or replaced by Chongqing Dajiang Power Equipment Co Ltd according to Subsection 4 below Any such part repaired or replaced under warranty will be warranted for the remainder of the period Any warranted part that is scheduled only for regular inspection in your Operator s Manual is warranted for the warranty period stated above Any such part repaired or replaced under warranty will be warranted for the remaining warranty period P Any warranted part that is scheduled for replacement as required maintenance in your Operator s Manual is warranted for the period of time
16. is defective the part will be repaired or replaced by Chongqing Dajiang Power Equipment Co Ltd OWNER S WARRANTY RESPONSIBILITIES e As the SORE owner you are responsible for the performance of the required maintenance listed in your operator s manual Chongqing Dajiang Power Equipment Co Ltd recommends that you retain all receipts covering maintenance on your SORE but Chongqing Dajiang Power Equipment Co Ltd can not deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance e As the SORE owner you should however be aware that Chongqing Dajiang Power Equipment Co Ltd may deny your warranty coverage if your SORE or a part has failed due to abuse neglect improper maintenance or unapproved modifications e You are responsible for presenting your SORE to distribution center or service center authorized by Chongqing Dajiang Power Equipment Co Ltd as soon as the problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities please contact Chongqing Dajiang Power Equipment Co Ltd through website or phone listed below Brand Website Phone BlackMax www blackmaxtools com 1 866 340 3912 DEFECTS WARRANTY COVERAGE Adopted by the Air Resources Board Chongqing Dajiang Power Equipment Co Ltd warrants to the ultimate purchaser and
17. n a tierra Los Reglamentos Nacionales de i Electricidad exigen que el generador est debidamente conectado a una tierra aprobada Comuniquese con der of the engine They are Very HOT and will un electrista para todo lo relacionado con los requistos de conexi n a tierra 940513013 00 cause severe burns Don t put any flammable or combustible materials in the direct path of CLEARANCE WARNING the exhaust While operating and storing keep at least 3 feet of clearance on all sides of this product including overhead Allow a minimum of 30 minutes of cool down time before storage Heat created by muffler and exhaust gases could be hot enough to cause serious burns and or ignite com bustible objects Page 7 English ELECTRICAL EXTENSION CORD CABLE SIZE Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load Inadequate size cables can cause a voltage drop which can damage the appliance and overheat the cord Maximum Allowable Cord Length 8Wire 0Wire 2Wire t4Wire 16Wire 600 ft 375 ft 250 ft 200 ft 125 ft ELECTRIC MOTOR LOADS It is characteristic of common electric motors in normal operation to draw up to six times their running current while starting This table may be used to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or too
18. n peligrosa inminente la cual si no se evita causar lesiones graves o mortales ADVERTENCIA Indica una situaci n peligrosa posible la cual si no se evita podr a causar lesiones graves o mortales PRECAUCI N Indica una situaci n peligrosa posible la cual si no se evita podr a causar i lesiones menores o leves Sin el s mbolo de alerta de seguridad Indica informaci n importante no relacionada con ning n peligro de lesiones como una situaci n que puede ocasionar da os f sicos Es posible que se empleen en este producto algunos de los siguientes s mbolos Le suplicamos estudiarlos y aprender su significado Una correcta interpretaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE Alerta de seguridad Lea manual del operador Alerta de condiciones h medas Descarga el ctrica Emanaciones t xicas Fuego Explosi n Superficie caliente Peligro al levantar Conexi n a tierra Electrocuci n DENOMINACI N EXPLICACI N Indica un peligro posible de lesiones personales Para reducir el riesgo de lesiones el usuario debe leer y comprender el manual del operador antes de usar este producto No exponga la unidad a la lluvia ni la use en lugares h medos Si no se usa la unidad en condiciones secas y no se observan pr cticas seguras de trabajo puede producirse una descarga el ctrica Con el funcionamiento del generador
19. of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction E In some areas generators are required to be registered with local utility companies m If the generator is used at a construction site there may be additional regulations which must be observed CHECKING ADDING LUBRICANT See Figure 7 NOTICE Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure Engine lubricant has a major influence on engine perfor mance and service life For general all temperature use SAE 10W 30 is recommended Always use a 4 stroke motor lubricant that meets or exceeds the requirements for API service classification SJ NOTE Non detergent or 2 stroke engine lubricants will damage the engine and should not be used E Unscrew the oil cap dipstick and remove E Wipe dipstick clean and re seat in hole do not re thread m Remove dipstick again and check lubricant level Lubri cant level should fall between the hatched areas on the dipstick E lflevelis low add engine lubricant until the fluid level rises to the upper portion of the dipstick E Replace and secure the oil cap dipstick Page 13 English OPERATION USING FUEL STABILIZER Fuel gets old oxidizes and breaks down over time Adding a fuel stabilizer not included extends the usable life of fuel and helps prevent deposits from forming that
20. ouvre en utilisant le robinet de carburant TERMINAL DE CONEXION A TIERRA El terminal de conexi n a tierra se utiliza para ayudar a conectar a tierra correctamente el generador como ayuda de protecci n contra descargas el ctricas Consulte con un electricista local con respecto a los requisitos de conexi n a tierra en el rea geogr fica donde se encuentre usted TAPA DE RELLENO DE ACEITE VARILLA MEDIDORA DE ACEITE Retire la tapa de relleno de aceite varilla medidora de aceite para revisar el nivel y a adir lubricante al generador cuando sea necesario SENSOR DE BAJO LUBRICANTE Cuando el nivel de lubricante del motor sea bajo el sensor de bajo lubricante en la pantalla digital se iluminar y el motor se apagar autom ticamente TAP N DE DRENAJE DEL ACEITE Al cambiar el lubricante de motor se afloja el tap n de drenaje del aceite para permitir el drenaje del lubricante usado RECEPT CULOS Su generador cuenta con las siguientes tomas de corriente monofasicas de 60 Hz dos receptaculos de 120 VAC 20 A un recept culo de cierre por torsi n de 120 VAC 30 A y un recept culo de 120 VAC 30 A para casas rodantes Los recept culos pueden utilizarse para accionar los aparatos iluminaci n el ctrica herramientas y motores apropiados MANGO DEL ARRANCADOR RETR CTIL El mango del arrancador retr ctil se usa junto con el interruptor del motor para arrancar el motor del generador P gina 10 Espa ol ARMA
21. result in elec trocution especially if the generator is equipped with a wheel kit National Electric Code requires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements A WARNING Do not allow familiarity with this product to make you careless Remember that a careless fraction of asecond is sufficient to inflict serious injury A WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury Before each use inspect the entire product for damaged missing or loose parts such as screws nuts bolts caps etc Tighten securely all fasteners and caps and do not operate this product until all missing or damaged parts are replaced Please contact an authorized service center for assistance APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING THE UNIT E Only use OUTSIDE and far away from windows doors and vents m NEVER use inside a home or garage EVEN IF doors and windows are open m Always position the generator on a flat firm surface SPECIAL REQUIREMENTS There may be General or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use
22. service center for BLACKMAX generators This warranty does not cover repair if E normal usehas exhausted the useful life of the generator and wear and tear items including batteries fixed and removable control panels including corresponding cords and plugs digital displays tires outlet plugs and circuit breakers switches and extension cords if applicable m the customer fails to install maintain and operate the product in accordance with the instructions and recommendations of the company set forth in the generator operator s manual NW the product is used as rental equipment mM damage occurs due to freezing water exposure rust corrosion thermal expansion fire dropping or improper use This warranty does not cover freight or labor charges associated with the inspection and testing of generators which are found not to be a valid warranty claim Gasoline Engine Warranty The gasoline engine on this generator is separately warranted by the engine manufacturer and is serviced through the engine manufacturer s authorized service center network OWT Industries Inc disclaims any and all express or implied warranties with respect to the gasoline engine OWT INDUSTRIES INC MAKES NO WARRANTIES REPRESENTATIONS OR PROMISES AS TO THE QUALITY OR PERFORMANCE OF THIS GENERATOR OTHER THAN THOSE SPECIFICALLY STATED IN THIS WARRANTY HOW TO OBTAIN SERVICE To obtain service for this BLACKMAX generator you must ret
23. the unit lf problem persists after trying the above solutions contact your nearest authorized service center for assistance E Hard starting or stalling after starting E Rough idle E Misfiring or backfiring under load E Afterburning backfiring Black exhaust smoke or high fuel consumption If you encounter any of these symptoms have the unit inspected and repaired by the nearest authorized service center Page 19 English WARRANTY BLACKMAX GENERATOR LIMITED WARRANTY Proof of purchase must be presented when requesting warranty service This product is manufactured by OWT Industries Inc All warranty communications should be directed to OWT Industries Inc attn Generator Technical Service at toll free 1 800 726 5760 WHAT IS COVERED UNDER THE LIMITED WARRANTY This BLACKMAX generator is warranted to the original purchaser only to be free from defects in material and workmanship subject to certain exceptions and limitations stated below within these time periods from the date of purchase E Two 2 years if the product is used solely for personal family or household use mM One 1 year if the product is used for business or commercial use Warranties for other BLACKMAX products may vary WHAT IS NOT COVERED This warranty does not apply to damage from misuse alterations abuse normal wear andtear lack of maintenance accidents or repairs made or attempted by anyone other than an authorized
24. with foreign material such as leaves etc Do not use a garden hose to clean the generator Water en tering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator To clean the unit E Use a soft bristle brush and or vacuum cleaner to loosen and remove dirt and debris EH Clean air vents with low pressure air that does not exceed 25 psi Wipe the exterior surfaces of the generator with a damp cloth CHECKING CLEANING AIR FILTER See Figure 14 For proper performance and long life keep air filter clean E Loosen the knob on the bottom of the air filter cover Remove cover and set aside E Remove the air filter E Remove the deflector Wipe with a clean cloth and replace in the air filter unit m If the air filter is dirty wash it with warm soapy water Rinse and squeeze to dry E Apply a light coat of engine lubricant to the air filter then squeeze it out E Replace the air filter E Replace the air filter cover and tighten knob to secure NOTE Do not run the generator without the air filter or gasket Rapid engine wear will result CHANGING ENGINE LUBRICANT See Figure 15 E Remove the oil cap dipstick m Place a container underneath the oil drain plug to collect used lubricant as it drains E Unscrew the oil drain plug and remove Allow lubricant to drain completely NOTE Drain the lubricant while the engine is still warm but not hot
25. y explosivos Para evitar lesiones y danos fisicos serios maneje con cuidado la gasolina Mant ngala lejos de fuentes de ignici n man jela solamente al aire libre no fume mientras vierta la gasolina y limpie de inmediato cualquier derramamiento que ocurra Al abastecer de gasolina la generador aseg rese de que la unidad est asentada en una superficie horizonal nivelada Si est caliente el motor permita que se enfr e la generador antes de reabastecerla de gasolina SIEMPRE llene el tanque al aire libre y teniendo apagada la m quina E Retire la tapa de combustible m Llene el tanque de combustible hasta una altura de 2 5 cm 1 pulg abajo del cuello del tanque E Coloque de nuevo la tapa del tanque de combustible y asegurela NOTA Siempre utilice gasolina sin plomo con un octanaje nominal inicial de 86 o mayor Nunca utilice gasolina vieja pasada o contaminada y no utilice mezcla de aceite y gasolina No permita que entre tierra o agua en el tanque de combustible P gina 14 Espa ol FUNCIONAMIENTO ARRANQUE DEL MOTOR Vea las figuras 9 a 11 AVISO Teniendo la unidad en una superficie nivelada y con el motor apagado revise el nivel de lubricante cada vez antes de usar el generador NOTA Si el generador no est en una superficie nivelada es posible que no arranque o se apague durante su funcionamiento E Desconecte todas las cargas del generador E Ponga la v lvula de combustible en
26. CUSTOMER SERVICE 1 800 726 5760 To register your BlackMax product please visit http register blackmaxtools com O P E RATO R S MAN UAL Mexico SERVICIO AL CLIENTE Manual del operador 1 800 843 1111 Para registrar su producto de 3090 WATT G E N E RATO R BlackMax por favor visita http register black tools Generador 3650 watts p register blackmaxtools com BM903655DA NOTICE AVISO Do not use E15 or E85 fuel or gt fuel containing greater than EO 10 ethanol in this product a It is a violation of federal law and will damage the unit and void your warranty No utilice combustibles E15 o E85 ni combustibles que contengan m s de 10 de etanol con este producto Esto constituye una violaci n a la ley federal da ar la unidad y anular la garant a TE VU SS a lt lt SE NEUTRAL BONDED TO FRAME PUNTO NEUTRO CONECTADO AL MARCO Your generator has been engineered and manufactured to our high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance A WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product If you do not understand the warnings and instructions in the operators manual do not use this product SAVE THIS MANUAL FOR FUTURE REFERENCE Su generador ha sido disenado y fabricado de conformidad co
27. DO DESEMPAQUETADO Este producto requiere armarse E Corte cuidadosamente los lados de la caja y despu s retire la herramienta y cualesquier accesorios de la caja Aseg rese de que est n presentes todos los art culos enumerados en la lista de empaquetado NOTA Esta herramienta es pesada y requiere al menos de dos personas para levantarla Para evitar una lesi n en la espalda lev ntela con sus piernas no con su espalda ADVERTENCIA No utilice este producto si alguna pieza incluida en la lista de piezas sueltas ya est ensamblada al producto cuando lo desempaqueta El fabricante no ensambla las piezas de esta lista en el producto stas deben ser instaladas por el usuario El uso de un producto que puede haber sido ensamblado de forma inadecuada podr a causar lesiones personales graves E Inspeccione cuidadosamente la unidad para asegurarse que no haya sufrido ninguna rotura o da o durante el transporte E No deseche el material de empaquetado hasta que haya inspeccionado cuidadosamente el producto y lo haya utilizado satisfactoriamente E Si hay piezas da adas o faltantes le suplicamos llamar al servicio al cliente donde le brindaremos asistencia A ADVERTENCIA Si hay piezas danadas o faltantes no utilice este producto sin haber reemplazado todas las piezas Usar este producto con falta o esta danada alguna pieza podria tener como resultado herida personal grave A ADVERTENCIA No intente modifi
28. M Replace with new fuel filter E Reinstall fuel lines to new fuel filter E Turn the fuel valve to the ON position TRANSPORTING E Turn engine switch OFF Turn the fuel valve to the OFF position Make sure engine and exhaust of unit is cool Empty the fuel tank Do not drop or strike unit or place under heavy objects Page 17 English MAINTENANCE STORAGE When preparing the generator for storage allow the unit to cool completely then follow the guidelines below STORAGE PRIOR TO STORING TIME E Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances months 2 to 1 Drain fuel from carburetor Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances 1 year or more Drain fuel from the carburetor Remove spark plug Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances Put a tablespoon of engine lubricant into the spark plug cylinder Turn the engine slowly with the pull rope to distribute the lubricant Reinstall spark plug Change engine lubricant After removal from storage E Fill with fresh gasoline NOTE If storing gasoline in suitable container for later use make sure gasoline has been treated with fuel stabilizer according to stabilizer manufacturer s instructions MAINTENANCE SCHEDULE NOTE If a separate engine manual is provided for this ge
29. QUATION UN USAGE PARTICULIER Toutes les garanties implicites y compris les garanties de valeur marchande ou d ad quation un usage particulier ne pouvant pas tre exclues en raison des lois en vigueur sont limit es une dur e de trois ans compter de la date d achat OWT Industries Inc d clinent toute responsabilit pour les dommages directs ou indirects Certains tats et provinces ne permettant pas de limitation sur la dur e des garanties implicites et ou l exclusion ou la limitation des dommages directs ou indirects les restrictions ci dessus peuvent ne pas tre applicables Cette garantie donne au consommateur des droits sp cifiques et celui ci peut b n ficier d autres droits qui varient selon les tats ou provinces Cette garantie s applique aux produits vendus aux tats Unis au Canada et au Mexique uniquement Veuillez consulter le site web de BLACKMAX www blackmaxtools com ou appelerle au 1 800 726 5760 appel gratuit pour trouver le site de fabricant autorisee entretien le plus proche pour toute reparation au titre de la garantie ou non de ce g n rateur OWT Industries Inc P O Box 35 Highway 8 Pickens SC 29671 Pagina 20 Espanol GARANT A DECLARACI N DE GARANT A DE CONTROL DE EMISI N DE ESTADOS UNIDOS DERECHOS Y OBLIGACIONES DEL CONSUMIDOR SEG N LA GARANT A La Agencia de Protecci n Ambiental Environmental Protection Agency EPA de EE UU y Chongqing Dajiang Power E
30. TALLING THE HANDLE BRACKET See Figure 5 NW Locate the following items Handle Bracket 2 Bolts 1 4 20 x 1 5 in 2 Lock Nuts 1 4 20 m Place the handle bracket on the generator frame on the side where the recoil starter is located EH Slide the bolts 1 4 20 x 1 5 mm through the holes in the handle bracket and generator frame install lock nuts and tighten securely Page 12 English OPERATION DANGER Carbon Monoxide Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains high levels of carbon mon oxide CO a poisonous gas you cannot see or smell If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO m Never use a generator inside homes garages crawl spaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Us ing a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You could have carbon monoxide poisoning A DANGER Failure to properly ground generator can
31. The warranty period begins on the date the equipment is delivered to an ultimate purchaser b General Evaporative Emissions Warranty Coverage The equip ment must be warranted to the ultimate purchaser and any subsequent owner that the evaporative emission control system when installed was 1 Designed built and equipped so as to conform with all applicable regulations and 2 Free from defects in materials and workmanship that cause the failure of a warranted part for a period of two years c The warranty on evaporative emissions related parts will be interpreted as follows 1 Any warranted part that is not scheduled for replacement as required maintenance in the written instructions must be warranted for the warranty period defined in subsection b 2 If any such part fails during the period of warranty cov erage it must be repaired or replaced by the manufacturer issuing the warranty Any such part repaired or replaced Page 22 under the warranty must be warranted for a time not less than the remaining warranty period 2 Any warranted part that is scheduled only for regular inspec tion in the written instructions must be warranted for the warranty period defined in subsection b 2 A statement in such written instructions to the effect of repair or replace as necessary will not reduce the period of warranty coverage Any such part repaired or replaced under warranty must be warranted for a time not le
32. UDES ELEVADAS Se requieren modificaciones espec ficas para una operaci n a altitudes elevadas Comun quese con su centro de servicio autorizado para obtener informaci n importante sobre dichas modificaciones La operaci n de este motor sin la modificaci n por altitud apropiada podr a aumentar las emisiones del motor y disminuir el ahorro y desempe o del combustible P gina 15 Espa ol MANTENIMIENTO A ADVERTENCIA Al dar servicio a la unidad s lo utilice piezas de repuesto id nticas El empleo de piezas diferentes podr a causar un peligro o da ar el producto Solamente las piezas enumeradas en la lista de piezas pueden ser reparadas o cambiadas por el consumidor Todas las piezas restantes deben ser reemplazadas en un centro de servicio autorizado MANTENIMIENTO GENERAL Antes de cada uso inspeccione todo el producto para detectar alg n da o partes faltantes o sueltas comotornillos tuercas pernos tapas etc Ajuste firmemente todos los sujetadores y las tapas y no active este producto hasta que todas las partes faltantes o da adas sean reemplazadas Comun quese con un centro de servicio autorizado para recibir asistencia Mantenga el generador en un entorno limpio y seco en el cual no est expuesto al polvo tierra humedad o vapores corrosivos No permita que las ranuras de aire de ventilaci n del generador se tapen de materia extra a como hojas etc No utilice una manguera de jard n para li
33. a 4 MSM SN AAA AA AA a AE A ae ane 5 7 lt A A it an ao ac te ou te ea de te de ee a ae a ete ee ln 8 9 O RN O 10 m ASS MON tement nd Nepal rie ne nono 11 12 e HOS ETS QT ER as 13 15 a Mante AMC EEE 16 18 m TroubleshooiInd dci 19 m NAT a Sots do toa ates adnan al ne een Chemie ne con a en En eo te 20 22 E PAS ORO Cl VIG xe a nn aan TE Back Page INTRODUCTION This product has many features for making its use more pleasant and enjoyable Safety performance and dependability have been given top priority in the design of this product making it easy to maintain and operate A DANGER GROUNDING THE GENERATOR To reduce the risk of shock or electrocution generator must be properly grounded The nut and ground terminal on the frame must always be used to connect the generator to a suitable ground source The ground path should be made with 8 size wire Connect the terminal of the ground wire between the lock washer and the nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source The National Electric Code contains several practical ways in which to establish a good ground source If a steel or iron rod is used it should be at least 5 8 in diameter and if a nonferrous rod is used it should be at least 1 2 in diameter and be listed as material for grounding Drive the rod or pipe to a depth of 8 ft If a rock bottom is encountered less than 4 ft down bury the rod or pipe in a tre
34. a l inspection et aux essais de g n rateur determined ne pas tre une r clamation valide de garantie Moteur essence Garantie TheLe moteur essence de ce g n rateur est couvert s par ment par la garantie du fabricant du moteur et est entretenu parle r seau de centres d entretien autoris du fabricant du moteur OWT Industries Inc en d mentez et toutes les garanties explicites ou implicites pour ce moteur essence OWT INDUSTRIES INC NE FONT AUCUNE AUTRE GARANTIE REPR SENTATION OU PROMESSE CONCERNANT LA QUALIT ET LES PERFORMANCES DE SES OUTILS MOTORIS S AUTRES QUE QUE CELLES EXPRESS MENT INDIQU ES DANS LE PR SENT DOCUMENT R PARATIONS SOUS GARANTIE Pour toute r paration sous garantie cet g n rateur BLACKMAX devra tre retourn en port pay un centre de r parations agr g n rateur BLACKMAX L adresse du centre de r paration agr le plus proche peut tre obtenue en appelant au 1 800 726 5760 appel gratuit ou en acc dant au site Internet BLACKMAX www blackmaxtools com Au moment de demander un entretien sous garantie il faut pr senter le recu de vente original dat Le centre de r paration agr corrigera tout d faut de fabrication et r parera ou remplacera notre discr tion gratuitement toute pi ce d fectueuse AUTRES LIMITATIONS Sous r serve des lois en vigueur toutes les garanties implicites sont exclues y compris les GARANTIES DE VALEUR MARCHANDE ou D AD
35. agado NW Quite la tuber a del combustible de ambos lados del filtro apretando los extremos del sujetador de retenci n con pinzas E Deslice la tuber a de combustible Reemplazo del filtro de combustible E Vuelva a instalar las tuber as de combustible al nuevo filtro de combustible E Girelav lvula de combustible hasta la posici n Encendido TRANSPORTE E Ponga el interruptor del motor en OFF APAGADO E Ponga la v lvula de combustible en la posici n OFF APAGADO m Aseg rese de que est n fr os el motor y el escape de la unidad m Vac e el tanque de combustible E No deje caer la unidad no la golpee ni la coloque bajo objetos pesados P gina 17 Espa ol MANTENIMIENTO ALMACENAMIENTO Al preparar el generador para guardarlo deje que la unidad se enfr e por completo y luego siga los lineamientos se alados abajo TIEMPO DE ALMACENAMIENTO ANTES DE GUARDARLO Menos de dos meses Vac e el tanque de combustible y col quelo en un recipiente apropiado seg n lo establecido por las disposiciones estatales y locales De dos meses a un Drene el combustible del carburador a o Vac e el tanque de combustible y col quelo en un recipiente apropiado seg n lo establecido por las disposiciones estatales y locales Un a o o m s Drene el combustible del carburador Retire la buj a Vac e el tanque de combustible y col quelo en un recipiente apropiado seg n lo establecido por las disposiciones e
36. anas NO proporciona suficiente aire fresco S LO utilice el generador al aire libre y lejos de ventanas puertas y respiraderos abiertos Estas aberturas pueden atraer los gases de escape del generador Incluso si utiliza el generador correctamente el CO puede ingresar en su hogar SIEMPRE utilice una alarma de CO de pilas o con pilas de respaldo en su hogar Si comienza a sentirse descompuesto mareado o d bil luego de que el generador estuvo funcionando trasl dese adonde haya aire fresco INMEDIATAMENTE Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono A PELIGRO El incumplimiento de conectar correctamente a tierra el generador puede resultar en electrocuci n especialmente si el generador est equipado con un conjunto de ruedas El Reglamento Nacional de Electricidad exige que el generador est debidamente conectado a una tierra aprobada Comun quese con un electricista para todo lo relacionado con los requisitos de conexi n a tierra A ADVERTENCIA No permita que su familiarizacion con este producto lo vuelva descuidado Tenga presente que un descuido de un instante es suficiente para causar una lesion grave por el fabricante de este producto El empleo de aditamentos o accesorios no recomendados podria causar lesiones graves Antes de cada uso inspeccione todo el producto para detectar alg n da o partes faltantes o sueltas comotornillos tuercas pernos tapas etc Ajuste
37. antizada que no est en el calendario para reemplazo como lo requiere el mantenimiento en las instrucciones por escrito debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Si cualquier de dichas partes fallan durante el tiempo de la cobertura de la garant a debe ser reparada o reemplazada por el fabricante que expide la garant a Cualquier dicha pieza reparada o reemplazada en virtud de la garant a debe ser garantizada por un periodo no menor al tiempo restante de la garant a B Cualquier pieza garantizada que est en el calendario s lo para inspecci n regular en las instrucciones por escrito debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Una declaraci n en dichas instrucciones por escrito para el efecto de reparar o reemplazar seg n sea necesario no reducir el tiempo de cobertura de la garant a Cualquier pieza reparada o reemplazada en virtud de la garant a debe ser garantizada por un periodo no inferior al tiempo restante de la garant a Cualquier pieza garantizada que est en el calendario para reemplazo como lo requiere el mantenimiento en las instrucciones por escrito debe ser garantizada por el tiempo previo al primer punto de reemplazo programado para esa pieza Si la pieza falla previa al primer cambio programado la pieza debe ser reparada o reemplazada por el fabricante que expide la garant a Cualquier pieza reparada o reemplazada e
38. articuliers ou pour usage domestique m Un 1 an sur les produits employes a des fins professionnelle ou commerciale Les garanties pour d autres produits de BLACKMAX peuvent changer CE QUI N EST PAS COUVERT Cette garantie ne couvre pas les dommages utilisations incorrectes alt rations abusives l usure normale et d chire une carence d entretien accidents ou tre caus s par des r parations ou des tentatives de r paration par quiconque autre que le personnel agr par BLACKMAX Cette garantie exclut la r paration dans les situations suivantes m la vie utile de la g n rateur a diminu en raison d une utilisation normale usure normale de certains l ments notamment les piles les panneaux de commande fixes et amovibles y compris les cordons correspondants et les fiches les crans num riques les pneus les prises et les disjoncteurs les interrupteurs et les cordons prolongateurs le cas ch ant NW le produit n est pas install entretenu et utilis conform ment aux instructions et aux recommandations de l entreprise qui sont d crites dans le manuel d utilisation du produit NW le produit est utilis aux fins de location E endommag en raison du gel de l exposition l eau de la rouille de la corrosion de la dilatation thermique du feu d une chute ou d une utilisation inadequate Cette garantie ne couvre pas les frais de transport ni les co ts de main d ceuvre relatifs
39. before the first scheduled replacement date for that part If the part fails before the first scheduled replacement the part will be repaired or replaced by Chongqing Dajiang Power Equipment Co Ltd according to Subsection 4 below Any such part repaired or replaced under warranty will be warranted for the remainder of the period prior to the first scheduled replacement point for the part Repair or replacement of any warranted part under the warranty provisions herein must be performed at a warranty station at no charge to the owner 5 Notwithstanding the provisions herein warranty services or repair will be provided at all of our distribution centers that are franchised to service the subject engines 6 The engine owner must not be charged for diagnostic labor that leads to the determination that a warranted part is in fact defective provided that such diagnostic work is performed at a warranty station 7 Chongqing Dajiang Power Equipment Co Ltd is liable for damages to other engine components proximately caused by a failure under warranty of any warranted part 8 Throughout the engine warranty period stated above Chongqing Dajiang Power Equipment Co Ltd will maintain a supply of warranted parts sufficient to meet the expected demand for such parts 9 Any replacement part may be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner Such use will not re
40. bles VERIFICACI N Y ABASTECIMIENTO DE LUBRICANTE Vea la figura 7 AVISO Si se intenta arrancar el motor antes de haberse abastecido debidamente de lubricante podr a descomponerse el equipo El lubricante de motor empleado es un factor de gran importancia en el rendimiento y vida de servicio del motor Para uso general a todas temperaturas se recomienda el aceite SAE 10W 30 Siempre utilice lubricante para motor de cuatro tiempos que satisfaga o sobrepase los requisitos SJ de clasificaci n de servicio API NOTA El lubricante sin detergente o para motor de dos tiempos da a el motor por lo cual no debe usarse E Desenrosque la tapa de relleno de aceite varilla medidora de aceite y ret rela E Limpie la varilla de nivel y vuelva a asentarla en el agujero no la enrosque E Retire denuevo la varilla medidora de lubricante y verifique el nivel de lubricante El nivel de lubricante siempre debe estar entre las reas cubierta con rayas entrecruzadas de la varilla medidora NW Si esta bajo el nivel abastezca de lubricante el motor hasta que el nivel del fluido alcance la parte superior de la varilla NW Vuelva a colocar la tapa de relleno de aceite varilla medidora de aceite y asegurela USO DE ESTABILILZADOR DE COMBUSTIBLE El combustible se hace viejo se oxida y descompone al paso del tiempo Agregando estabilizador de combustible no incluido se prolonga la vida til del combustible y se evita la formaci n
41. brecorriente en la capacidad del generador seg n se describi anteriormente AVISO No exceda la capacidad del generador Si excede la capacidad de corriente amperios y potencia vatios del generador puede da ar el generador y los dispositivos el ctricos conectados al mismo W de funcio arranque namiento adicionales estimados estimados Emergencia 7 En casa espera io de rajo Faledro el ctrico 1 2 HP soo 0 Rociador de aire comprimido 1 3 1200 HP L mpara de trabajo de hal geno 1000 1000 de cuarzo Compresor de aire 1 HP 1600 4500 Sierra circular 7 1 4 pulg 184 1400 2300 mm Cepillo de juntas 6 pulg 150 1800 1800 mm Sierra de ingletes 10 pulg 254 1800 1800 mm Sierra de banco sierra radial de 2000 2000 brazo 10 pulg 254 mm Los valores de potencias en vatios indicados son aproximados Verifique la potencia real de cada herramienta o aparato W de Herramienta o aparato P gina 9 Espa ol CARACTER STICAS ESPECIFICACIONES DEL PRODUCTO MOTOR Tipo de MOto ccinn 208 cc OHV Buj a de repuesto oocccocccccoccccococononinnnncnnnnnnnnnnnnnnnos LG F7TC Volumen de aceite de motor 0 61 L 0 64 cuartos Volumen de combustible 15 1 L 4 galones GENERADOR volta NOMINA abla 120V Amperaje nominal 30 4 A Potencia nominal en marcha en vatios 3 650 W Potencia nominal en arranque en vatios
42. can clog the fuel system Follow fuel stabilizer manufacturer s directions for correct ratio of stabilizer to fuel WE Mix fuel stabilizer and gasoline prior to filling the tank by using a gas can or other approved fuel container and shaking gently to combine NOTE Tocontrol the amount of fuel stabilizer being added to the engine always mix fuel stabilizer with gasoline before fueling the tank rather than adding fuel stabilizer directly into the generator s fuel tank E Replace and secure the fuel tank cap NW Start and run the engine for at least 5 minutes to allow stabilizer to treat the entire fuel system OXYGENATED FUELS NOTICE Do not use E15 or E85 fuel or fuel containing greater than 10 ethanol in this product It is a violation of federal law and will damage the unit and void your warranty Fuel system damage or performance problems resulting from the use of an oxygenated fuel containing more than the percentage of oxygenates stated below are not covered under warranty Ethanol Gasoline containing up to 10 ethanol by volume commonly referred to as E10 is acceptable E15 and E85 are not CHECKING ADDING FUEL See Figure 8 A WARNING Gasoline and its vapors are highly flammable and ex plosive To prevent serious personal injury and property damage handle gasoline with care Keep away from igni tion sources handle outdoors only do not smoke while adding fuel and wipe up spills immediately
43. cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents 44 PELIGRO Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno que no puede verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas Page 6 English SYMBOLS FUEL WARNING DANGER PELIGRO No smoking when filling with gasoline Do not overfill Full level is 1 in below Risk of Fire Check for any fuel overflow or leaking Stop the engine before refueling Riesgo de incendio Revise si hay alg n derrame o fuga de combustible Apaque el motor antes de poner combustible the top of the fuel neck Stop the en gine for five minutes before refueling to avoid the heat from the muffler igniting fuel vapors ENGINE LUBRICANT WARNING 940974004 01 You must add lubricant before first Add lubricant to full mark to start Engine will not start or operating the generator Always check will shut off if lubricant is too low OE TE er ean rele Agregue lubricante hasta la marca de lleno para arrancar El tion The lubricant level should always motor no arrancar o se apagar si el nivel de lubricante register between the hatched areas on esta demasiado baj
44. car esta producto ni introducir accesorios no recomendados para la misma Cualquier alteracion o modificaci n constituye maltrato y puede causar una condici n peligrosa y como consecuencia posibles lesiones corporales graves A ADVERTENCIA No intente accionar el generador antes de terminar de armarlo De lo contrario puede ocurrir un riesgo de lesiones graves LISTA DE PIEZAS SUELTAS Vea la figura 2 Los siguientes accesorios vienen incluidos N m ref Descripci n Cant 1 Tuerca de mariposa 1 4 20 7 2 WRUCOAS ia 2 3 Perno 3 8 16 x 4 25 pulg occcooccccccnocccnccocnnnos 2 4 PIG de Soporte sima 2 ar IMAN O arcadas a 1 O ESPACIO aii 2 7 Abrazadera del mango cocccocccconccnnncnnniconinaninannnos 1 8 Pernos 1 4 20 x 1 5 pulg 7 9 Tuercas de bloqueo 3 8 16 2 10 Botella de lubricante para motor 1 Manual del operador no se ilustra 1 HERRAMIENTAS NECESARIAS Vea la figura 2A Para armar la unidad se necesitan las siguientes herramientas no incluido o dibujado para escalar EH Llaves de casquillo y o llaves de combinaci n NOTA Ponga combustible ni lubricante en el generador antes de instalar las pies y ruedas INSTALACI N DE LOS PIES Vea la figura 3 m Eleve el extremo del generador donde est ubicado el arrancador retr ctil hasta una altura suficiente que permita el acceso
45. carburetor before storing DRAINING THE FUEL TANK E Turn the engine switch OFF E Turn the fuel valve to the OFF position E Remove the fuel line from the petcock by squeezing the ends of the retaining clip and sliding the fuel line off E Install one end of a drain line over the petcock and place the other end in a fuel container large enough to catch the fuel being drained from the tank NH Turn the fuel valve to the ON position When the fuel has drained from the tank close the fuel valve and reinstall fuel line on petcock DRAINING THE CARBURETOR NH Turn the engine switch OFF NH Turn the fuel valve to the OFF position E Position a suitable container under the carburetor drain screw to catch fuel loosen the screw E Allow fuel to drain completely into container E Retighten drain screw NOTE Consult hazardous waste management guidelines in your area for the proper way to dispose of used fuel REPLACING FUEL FILTER See Figure 20 Occasionally the fuel filter may become clogged and need replacing To purchase a replacement fuel filter contact customer service at 1 800 726 5760 NOTE Fuel tank must be empty before replacing fuel filter Run unit until tank is empty if needed or inspect filter prior to fill up To replace M Turn the fuel valve to the OFF position m Remove the fuel line from both sides of the filter by squeezing the ends of the retaining clip with pliers WN Slide the fuel line off m
46. de dep sitos los cuales pueden tapar el sistema del combustible Sigalas instrucciones del fabricante del estabilizador de combustible en cuanto a la debida proporci n estabilizador combustible m Vierta el estabilizador en el tanque de combustible y despu s ll nelo de gasolina de conformidad con las instrucciones anteriores NOTA Pueden mezclarse el estabilizador y la gasolina antes de llenar el tanque para ello utilice una lata de gasolina u otro recipiente aprobado para combustible y ag tela suavemente para realizar la mezcla E Coloque de nuevo la tapa del tanque de combustible y aseg rela E Arranque el motor y d jelo funcionar por lo menos cinco minutos para permitir que el estabilizador trate todo el sistema de combustible que contengan m s de 10 de etanol con este producto Esto constituye una violaci n a la ley federal da ar la unidad y anular la garant a No est n cubiertos en la garant a los problemas de desempe o o da os al sistema de combustible producidos por el uso de un combustible oxigenado con un contenido superior a los porcentajes de alcohol o compuesto de ter se alados abajo Etanol Las gasolinas con un contenido de 10 de etanol por volumen comunmente conocida como E10 es aceptables Las gasolinas E15 y E85 no lo son VERIFICACI N Y ABASTECIMIENTO DE COMBUSTIBLE Vea la figura 8 A ADVERTENCIA La gasolina y los vapores de la misma son extremadamente inflamables
47. de evitar da os siempre tenga una carga adicional enchufada al generador en caso de usarse equipos de estado s lido tales como un aparato de televisi n Tambi n podria resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones de equipo de estado s lido P gina 8 Espa ol ASPECTOS EL CTRICOS CAPACIDAD DEL GENERADOR Cerci rese que el generador pueda suministrar suficientes vatios de potencia continua en marcha y de sobrecorriente al arrancar para los equipos que desee alimentar al mismo tiempo Siga estos pasos sencillos 1 Seleccione los equipos que desea alimentar al mismo tiempo 2 Sume la potencia continua en marcha en vatios de estos equipos Esta es la cantidad de potencia que el generador debe producir para mantener en marcha los equipos Observe la tabla de referencia de potencia en vatios a la derecha 3 Calcule cu nta potencia inicial al arranque en vatios necesitar La potencia inicial en vatios es la breve variaci n r pida de potencia necesaria para poner en marcha los aparatos o herramientas accionados con motor el ctrico como las sierras circulares o los refrigeradores Debido a que no todos los motores arrancan al mismo tiempo se puede calcular la potencia inicial total en vatios sumando s lo los equipos con el mayor valor de potencia inicial adicional a la potencia nominal del paso 2 Ejemplo Herramienta o Potencia continua Potencia arranque a
48. doble aislamiento Se recomienda 1 Usar dispositivos el ctricos con clavija de tres patillas conectada a tierra 2 Para asegurar la continuidad de la protecci n a tierra del generador al dispositivo utilice un cord n de extensi n para uso a la intemperie con un recept culo de tres orificios en un extremo y una clavija de tres patillas en el otro Revise y cumpla con todas las reglas federales estatales y locales relevantes en relaci n con las especificaciones de conexi n a tierra Consulte a un electricista calificado o t cnico de servicio si no ha comprendido completamente las instrucciones de conexi n a tierra o si no est seguro si el generador est conectado a tierra correctamente P gina 2 Espa ol INSTRUCCIONES DE SEGURIDAD IMPORTANTES A PELIGRO Monoxido de carbono Usar un generador en el interior LO MATARA EN POCOS MINUTOS Los gases de escape del generador contienen niveles altos de monoxido de carbono CO un gas venenoso que no puede verse ni olerse Si puede oler los gases de escape del generador esta respirando CO Pero incluso si no puede oler los gases de escape es posible que est respirando CO m Nunca use un generador dentro de su hogar garaje sotano ni demas espacios parcialmente encerrados En dichos espacios pueden acumularse niveles mortales de monoxido de carbono Usar un ventilador o abrir puertas y ventanas NO proporciona suficiente aire fresco SOLO utilice el generador al
49. duce the warranty obligations of Chongqing Dajiang Power Equipment Co Ltd 10 Add on or modified parts that are not exempted by the Air Resources Board may not be used The use of any non exempted add on or modified parts by the ultimate purchaser will be grounds for disallowing a warranty claims Chongaing Dajiang Power Equipment Co Ltd will not be liable to warrant failures of warranted parts caused by the use of a non exempted add on or modified part 11 The manufacturer issuing the warranty shall provide any documents that describe that manufacturer s warranty procedures or policies within five working days of request by the Air Resources Board EMISSION WARRANTY PARTS LIST The repair or replacement of any warranted part otherwise eligible for warranty coverage may be excluded from such warranty coverage if Chongqing Dajiang Power Equipment Co Ltd demonstrates that the engine has been abused neglected or improperly maintained and that such abuse neglect or improper maintenance was the direct cause of the need for repair or replacement of the part That notwithstanding any adjustment of a component that has a factory installed and properly operating adjustment limiting device is still eligible for warranty coverage The following emissions warranty parts for each engine family list is covered 1 Fuel Metering System a Gasoline carburetor assembly and its internal components b Carburetor gaskets c Fuel tank d Fue
50. e aceite H Coloque un recipiente bajo el tap n de drenaje del aceite para recoger el lubricant a medida que salga E Desenrosque el tap n de drenaje del aceite y ret relo E Permita que se drene completamente el lubricante NOTA Drene el aceite mientras est tibio el motor no caliente el aceite tibio se drena con mayor facilidad y compleci n A ADVERTENCIA No cambie el lubricante del motor cuando est caliente El contacto accidental con el lubricante del motor caliente podr a provocar quemaduras graves E Instale de nuevo el tap n de drenaje del aceite y apri telo firmemente E Reabastezca de lubricante la unidad de conformidad con las instrucciones indicadas en el apartado Verificaci n y abastecimiento de lubricante Para conocer la cantidad de lubricante que se debe agregar consulte la secci n anterior Especificaciones del producto de este manual o el manual del motor adjunto si corresponde E Reinstale la tapa de relleno de aceite varilla medidora de aceite NOTA El lubricante usado debe desecharse en un sitio de desecho aprobado Si necesita m s informaci n consulte a un concesionario de aceite de la localidad MANTENIMIENTO DE LA BUJ A Vea la figura 16 La buj a debe tener el debido espacio interelectr dico y debe estar libre de dep sitos para que el motor funcione de forma correcta Para verificar E Retire la tapa de la buj a E Limpie toda la tierra presente alrededor de la base
51. e ales de da o como roturas o agrietamientos en el aislamiento o da o en las espigas Los generadores fijos instalados de manera permanente son la mejor alternativa para abastecer de electricidad al hogar durante los cortes de energ a Incluso los generadores port tiles que est n conectados correctamente pueden sobrecargarse De esta manera los componentes del generador pueden recalentarse o exigirse demasiado lo que podr a producir una falla en el generador P gina 3 Espa ol INSTRUCCIONES DE SEGURIDAD IMPORTANTES m Use nicamente repuestos y accesorios autorizados y siga las instrucciones descritas en la secci n de Mantenimiento de este manual El empleo de piezas no autorizadas o el incumplimiento de las instrucciones de mantenimiento puede significar un riesgo de descarga el ctrica o de lesiones Mantenga la unidad seg n las instrucciones de mantenimiento se aladas en este manual del operador Inspeccione cada vez la unidad antes de usarla para ver si tiene tornillos flojos fugas de combustible etc Reemplacetoda pieza da ada REGLAS DE SEGURIDAD ESPEC FICAS ADVERTENCIA Cuando este generador se utiliza para abastecer el sistema de cableado de un edificio un electricista calificado debe instalar el generador que debe conectarse a un interruptor de transferencia como un sistema derivado independiente de conformidad con el Reglamento Nacional de Electricidad NFPA 70 El generador se co
52. e gasolina o reabastecido de gasolina de mala calidad El disyuntor est en apagado OFF Est defectuoso el dispositivo conectado Un leve ruido ocasional de cascabeleo o explosiones si la carga es pesada no debe ser causa de preocupaci n No obstante si tal cascabeleo o explosiones ocurren con una carga normal a velocidad estable del motor el problema puede ser la marca de gasolina utilizada Ponga el interruptor del motor en encendido ON Llene el tanque de combustible Drenetodo el sistema y reabast zcalo con combustible nuevo Revise el nivel del lubricante del motor y reabast zcalo si es necesario Abra la v lvula ON Reemplace la buj a Desplace izquierda de la palanca del anegador hasta la posici n START ARRANQUE Vac e el combustible y el carburador Reabastezca de gasolina fresca la unidad Reemplazar del filtro de combustible o comun quese con un centro de servicio autorizado Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combustible y el carburador Reabastezca de gasolina fresca la unidad Siel problema contin a comun quese con un centro de servicio autorizado Ponga en encendido ON el disyuntor de corriente alterna Pruebe con un dispositivo diferente Cambie a una marca diferente de gasolina y aseg rese de que sea de un octanaje de 86 por lo menos Si el problema contin a comun quese con un centro de
53. e para causar quemaduras graves y o prender fuego a objetos combustibles INFORMACI N SOBRE EL FUNCIONAMIENTO DE LA PANTALLA DIGITAL Vea la figura 13 La pantalla digital muestra el voltaje de CA de salida la frecuencia cu nto tiempo hace que el motor est en marcha desde la ltima vez que se lo encendi y la cantidad total de horas de uso de la unidad Para recorrer estas pantallas presione el bot n de selecci n Los indicadores que se encuentran debajo de la pantalla digital se encender n en secuencia para indicar el tipo de informaci n que se muestra en pantalla Hor metro El contador de horas lleva la cuenta de las horas que el motor ha estado en marcha desde la ltima vez que se lo encendi y de las horas totales de uso de la unidad Voltaje de corr alt Cuando se seleccione el indicador de voltaje de CA mostrar el voltaje de salida del generador Frecuencia Cuando se seleccione elindicador de frecuencia mostrar la frecuencia de salida del generador TRASLADO EL GENERADOR E Apague la generador Desconecte todos los equipos que est n enchufados al generador E Ponga la v lvula de combustible en la posici n OFF APAGADO E Permita un per odo de enfriamiento de 30 minutos antes de guardar la m quina E Con su pie en la parte trasera del bastidor incline la m quina alejada usted hasta que se equilibre en las ruedas luego empuje la m quina a la posici n deseada OPERACI N A ALTIT
54. e sea reparada o cambiada bajo garant a seguir estando garantizada por el resto del per odo de garant a 2 Cualquier pieza cubierta por la garant a que tenga programada nicamente una inspecci n peri dica en su manual del operador tiene garant a por el per odo de garant a indicado m s arriba Cualquiera de dichas piezas que sea reparada o cambiada bajo garant a seguir estando garantizada por el resto del per odo de garant a 3 Cualquier pieza cubierta por la garant a que tenga programado un cambio como parte del mantenimiento obligatorio en su manual del operador tiene garant a hasta el primer cambio programado de dicha pieza Si la pieza falla antes del primer cambio programado dicha pieza ser reparada o cambiada por Chongqing Dajiang Power Equipment Co Ltd de acuerdo con la Subsecci n 4 m s abajo Cualquiera de dichas piezas que sea reparada o cambiada bajo garant a seguir estando garantizada por el resto del per odo de garant a hasta el momento en el que est programado el primer cambio de la pieza 4 La reparaci n o el cambio de cualquier pieza con garant a seg n los t rminos de garant a aqu expuestos deben ser realizados en una estaci n designada sin cargo para el propietario 5 Sin perjuicio de los t rminos aqui expuestos el mantenimiento olas reparaciones relacionados con la garant a ser n realizados en todos nuestros centros de distribuci n que est n habilitados para realizar mante
55. ectrocution Keep the unit dry Keep the generator a minimum of 3 feet away from all types of combustible material Do not operate generator near hazardous material Do not operate generator at a gas or natural gas filling station E Donot touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury Do not allow the generator s gas tank to overflow when filling Fill to 1 in below the top neck of the gasoline tank to allow for fuel expansion Do not cover the fuel tank cap when the engine is running Covering the fuel tank cap during use may cause engine failure and or damage to the tool Do not smoke when filling the generator with gasoline Shut down the engine and allow to cool completely before adding gasoline or lubricant to the generator Do not remove the oil dipstick or the fuel tank cap when the engine is running Pay close attention to all safety labels located on the generator Keep children a minimum of 10 feet away from the gen erator at all times The unit operates best in temperatures between 23 F and 104 F with a relative humidity of 90 or less Specific modifications for high altitude performance are needed if the generator will always be operated at alti tudes above 5 000 feet Contact your nearest authorized service center for more information and to have these modifications performed Operating voltage and frequency requirement of all electronic e
56. ed on this product Please study them and learn their meaning Proper interpretation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION Safety Alert Indicates a potential personal injury hazard To reduce the risk of injury user must read and understand operators manual before using this product Wet Conditions Alert Do not expose to rain or use in damp locations Failure to use in dry conditions and to observe safe practices can result in electric shock Read Operator s Manual Electric Shock Running generator gives off carbon monoxide an odorless color Toxic Fumes less poison gas Breathing carbon monoxide can cause nausea fainting or death Fuel and its vapors are extremely flammable and explosive Fire Fire Explosion or explosion can cause severe burns or death To reduce the risk of injury or damage avoid contact with any hot Hot Surface surface To reduce the risk of serious injury avoid attempting to lift the generator alone Consult with local electrician to determine grounding requirements Ground before operation Failure to properly ground generator can result in electrocution especially if the generator is equipped with a wheel kit Lifting Hazard Electrocution Page 5 English SYMBOLS Some of the following symbols may be used on this product Please study them and learn their meaning Proper interp
57. ely after refueling Wipe spilled fuel from the unit Never attempt to burn off spilled fuel under any circum stances Generators vibrate in normal use During and after the use of the generator inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration Have damaged items repaired or replaced as necessary Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades For power outages permanently installed stationary gen erators are better suited for providing back up power to the home Even a properly connected portable generator can become overloaded This may result in overheating or stressing the generator components possibly leading to generator failure Page 3 English IMPORTANT SAFETY INSTRUCTIONS NW Maintain the unit per maintenance instructions in this Operator s Manual Use only authorized replacement parts and accessories and follow instructions in the Maintenance section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of shock or injury SPECIFIC SAFETY RULES E Inspect the unit before each use for loose fasteners fuel leaks etc Replace damaged parts WARNING When this generator is used to supply a building wiring system generator must be installed by a quali fied electrician and connected to a transfer switch as a separately d
58. embargo como propietario de equipo peque o para uso fuera de carreteras usted debe saber que OWT Industries Inc puede negarle la cobertura de la garant a si dicha equipo peque o para uso fuera de carreteras o una parte de la misma ha fallado debido a abuso descuido o mantenimiento indebido o modificaciones no autorizadas m Usted es responsable de presentar su equipo peque o para uso fuera de carreteras a un establecimiento de servicio de OWT Industries Inc tan pronto como surja el problema Las reparaciones amparadas por la garant a deben realizarse en un plazo razonable menor de 30 d as Si tiene alguna pregunta con respecto a la cobertura de la garant a debe comunicarse con OWT Industries Inc al 1 800 726 5760 REQUISITOS DE LA GARANT A DE DEFECTOS a El tiempo de garant a inicia en la fecha que el motor o equipo es entregado al comprador final b Cobertura de garant a de emisiones evaporativas general El equipo debe ser garantizado al comprador final y cualquier propietario subsecuente que cuando el sistema de control evaporativo instalado fue 1 Dise ado fabricado y equipado de conformidad con todas las normas aplicables y 2 Libre de defectos en los materiales y mano de obra que puedan causar el defecto de la parte garantizada por un tiempo de dos a os c La garant a en las piezas relacionadas con las emisiones evaporativas ser interpretada de la siguiente manera 1 Cualquier pieza gar
59. emo del conducto de drenaje en la llave de purga y coloque el otro extremo en un recipiente de combustible de la suficiente capacidad para recibir el combustible drenado del tanque E Ponga la v lvula de combustible en la posici n ON ENCENDIDO m Una vez que se haya drenado todo el combustible del tanque cierre la v lvula y vuelva a instalar el conducto en la llave de purga DRENAJE DEL CARBURADOR Ponga el interruptor del motor en OFF APAGADO E Ponga la v lvula de combustible en la posici n OFF APAGADO E Coloque un recipiente adecuado bajo el tornillo de drenaje del carburador para recibir el combustible afloje el tornillo m Permita que se drene completamente el combustible y caiga en el recipiente E Vuelva a apretar el tornillo de drenaje NOTA Consulte las normas de desecho de residuos peligrosos de la localidad donde se encuentre para averiguar la forma correcta de desechar el combustible usado REEMPLAZO DEL FILTRO DE COMBUSTIBLE Vea la figura 20 En algunas ocasiones el filtro de combustible puede obstruirse y deber reemplazarse Para comprar un filtro de combustible comun quese con el centro de asistencia de al 1 800 726 5760 NOTA El tanque de combustible debe estar vac o antes de reemplazar el filtro Sies necesario ponga en funcionamiento la unidad hasta vaciar el tanque o supervise el filtro antes de llenarlo Para reemplazar E Girela v lvula de combustible hasta la posici n Ap
60. erived system in accordance with NFPA 70 National Electrical Code The generator shall be connected through a transfer switch that switches all conductors other than the equipment grounding con ductor The frame of the generator shall be connected to an approved grounding electrode Failure to isolate the generator from power utility can result in death or injury to electric utility workers Do notusethis generatorto provide power for emergency medical equipment or life support devices This generator has a neutral bonded condition This means the system ground is connected electrically to the AC neutral wire Exhaust contains poisonous carbon monoxide a color less odorless gas Breathing exhaust can cause loss of consciousness and can lead to death If running in a confined or partially enclosed area the air may contain a dangerous amount of carbon monoxide To keep ex haust fumes from building up always provide adequate ventilation Always use a battery powered carbon monoxide detec tor when running the generator If you begin to feel sick dizzy or weak while using the generator shut it off and get to fresh air immediately See a doctor You may have carbon monoxide poisoning Place the generator on a flat stable surface with a slope of no more than 4 Operate in a well ventilated well lit area isolated from working areas to avoid noise interference Operating the generator in wet conditions could result in el
61. firmemente todos los sujetadores y las tapas y no active este producto hasta que todas las partes faltantes o da adas sean reemplazadas Comun quese con un centro de servicio autorizado para recibir asistencia APLICACIONES Este generador est dise ado para suministrar alimentaci n el ctrica para el funcionamiento de iluminaci n el ctrica compatible electrodom sticos herramientas y cargas de motor ANTES DE ACCIONAR LA UNIDAD E Solo utilicelo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos m NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas E Coloque siempre el generador sobre una superficie firme plana REQUISITOS ESPECIALES Es posible que se apliquen reglamentaciones de la Administraci n de Salud y Seguridad Ocupacional Occupational Safety and Health Administration OSHA generales o estatales c digos u ordenanzas locales al uso para el que fue dise ado el generador Consulte a un electricista calificado a un inspector de instalaciones el ctricas o a la agencia local con jurisdicci n E En algunas reas se deben registrar los generadores en las respectivas compa as de servicios p blicos locales E Si el generador es utilizado en una obra en construcci n es posible que se deban respetar reglamentaciones adicionales P gina 13 Espa ol FUNCIONAMIENTO COMBUSTIBLES OXIGENADOS AVISO No utilice combustibles E15 o E85 ni combusti
62. funciona mejor a una temperatura entre 5 y 40 C 23 y 104 F con una humedad relativa de 9 o menos El requerimiento de voltaje y frecuencia operativa de todos los equipos electr nicos debe comprobarse antes de enchufarlos a este generador Pueden ocurrir da os si el equipo no est dise ado para operar dentro de una variaci n de voltaje de 10 y una variaci n de frecuencia de 3 hz de los valores nominales que aparecen en la placa de identificaci n del generador Para reducir el riesgo de da os siempre tenga una carga adicional enchufada al generador en caso de usarse equipos de estado s lido tales como un aparato de televisi n Tambi n podr a resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones por ejemplo con una computadora Tambi n podria resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones de equipo de estado s lido Nunca utilice la unidad sin pantalla parachispas Para usarse s lo en el exterior Guarde estas instrucciones Cons ltelas con frecuencia y empl elas para instruir a otras personas que puedan utilizar esta producto Si presta a alguien esta producto facil tele tambi n las instrucciones P gina 4 Espa ol S MBOLOS Las siguientes palabras de se alizaci n y sus significados tienen el objeto de explicar los niveles de riesgo relacionados con este producto SE AL SIGNIFICADO S MBOLO PELIGRO Indica una situaci
63. g Dajiang Power Equipment Co Ltd RESPONSABILIDADES DEL PROPIETARIO EN RELACI N CON LA GARANT A e Como propietario del motor SORE usted es responsable de que se realice el mantenimiento obligatorio que indica el manual del operador Chongaing Dajiang Power Equipment Co Ltd le recomienda que guarde todos los comprobantes relacionados con el mantenimiento de su motor SORE aunque Chongqing Dajiang Power Equipment Co Ltd no puede rechazar la garant a por el solo hecho de que usted sea incapaz de presentar dichos comprobantes o de asegurar la realizaci n de todo el mantenimiento programado e Sin embargo como propietario del motor SORE debe tener en cuenta que Chongqing Dajiang Power Equipment Co Ltd puede rechazar la cobertura de garant a si su motor SORE o una de sus piezas fall debido al uso incorrecto la negligencia el mantenimiento inadecuado o la realizaci n de modificaciones no aprobadas e Usted es responsable de llevar su motor SORE a un centro de distribuci n o de mantenimiento autorizado por Chongqing Dajiang Power Equipment Co Ltd tan pronto como se presente el problema Las reparaciones amparadas por la garant a deben realizarse en un plazo razonable que no exceda los 30 d as Si tiene alguna pregunta relacionada con sus derechos y responsabilidades con respecto a la garant a comun quese con Chongqing Dajiang Power Equipment Co Ltd a trav s del sitio web o llamando al n mero de tel fono indicado a co
64. hat is plugged into the generator m Turn the fuel valve to the OFF position EH Allow 30 minutes of cool down time before storing the machine E Tilt the machine away from you until it balances on the wheels then roll the machine to the desired location HIGH ALTITUDE OPERATION Specific modifications are needed for high altitude operation Please contact your authorized service center for important information regarding these modifications Operating this engine withoutthe proper altitude modification may increase the engine s emissions and decrease fuel economy and performance Page 15 English MAINTENANCE WARNING When servicing use only identical replacement parts Use of any other parts could create a hazard or cause product damage Only the parts shown on the parts list are intended to be repaired or replaced by the customer All other parts should be replaced at an authorized service center GENERAL MAINTENANCE Before each use inspect the entire product for damaged missing or loose parts such as screws nuts bolts caps etc Tighten securely all fasteners and caps and do not operate this product until all missing or damaged parts are replaced Please contact an authorized service center for assistance Keep the generator in a clean and dry environment where it is not exposed to dust dirt moisture or corrosive vapors Do not allow the cooling air slots in the generator to become clogged
65. ine lubricant level and fill if necessary Fuel valve is OFF Turn fuel valve ON Spark plug faulty fouled or improperly Replace spark plug gapped Choke lever is in RUN position Move choke lever to START position Engine stored without treating or Drain fuel and carburetor Refuel with draining gasoline or refueled with bad fresh gasoline gasoline Dirty fuel filter Replace fuel filter or contact authorized service center Engine lacks power Dirty air filter Check air filter element Clean or replace as needed Engine stored without treating or Drain fuel and carburetor Refuel with draining gasoline or refueled with bad fresh gasoline lf problem continues gasoline contact your nearest authorized service center AC receptacle does not work Circuit breaker is OFF Turn ON the AC circuit breaker Item plugged in is defective Try a different item Generator makes a spark knock or An occasional light knocking or ping Switch to a different brand of gasoline pinging noise ing under heavy load is not a cause for making sure that the octane rating is 86 concern However if the knocking or or higher If problem continues contact pinging occurs under normal load at a your nearest authorized service center steady engine speed the problem may be with the brand of gasoline being used The following symptoms may indicate problems that will affect the emissions level of
66. ite M Handle mango N Ground terminal terminal de conexi n a tierra O Fuel valve v lvula de combustible P Muffler silenciador Q 20 amp AC circuit breakers 20 A disyuntors de circuito de CA R 120 Volt 30 amp twist lock receptacle toma de corriente de fijaci n por giro de 120 V y 30 A S Fuel tank vapor vent vent de vapeur du r servoir de carburant respirador del vapor del tanque de combustible A Bolt perno B Support foot pie de soporte C Lock nut tuerca de bloqueo D Frame armaz n A Wheel rueda B Lock nut tuerca de bloqueo C Bolt perno D Wheel mounting hole agujero para rueda E Spacer espaciador C o A Handle bracket abrazadera del mango B Bolt perno C Lock nut tuerca de bloqueo fu A Handle bracket abrazadera del mango B Handle mango C Hole agujero D Bolt perno E Lock nut tuerca de bloqueo A Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite B Lubricant fill hole agujero de llenado de aceite Fig 8 A B SON pa SN SS A Fuel cap tapa del tanque de combustible B Fuel tank tanque de combustible Fuel valve interruptor del motor B Engine switch v lvula de combustible C Recoil starter grip mango del arrancador retr ctil W a anni gt EE A Fuel valve valvula de combustible B Off apagado C On ence
67. itir un reclamo de la garant hecho de acuerdo con este art culo El fabricante que expide la garant a no ser responsable en virtud de este art culo a garantizar defectos de piezas garantizadas debido al uso de una pieza modificada o a adida LISTA DE PIEZAS DE GARANT A DE EMISI N 1 Tanque de combustible N Tapa del tanque Mangueras de combustible Recept culo de carb n O1 Mangueras de vapor O Abrazaderas de manguera N Conectador de la manguera 8 V lvula de retenci n de vapor combustible Las instrucciones por escrito para el mantenimiento y uso del sistema de control de emisiones evaporativas por el propietario deben ser facilitadas con todos equipo peque o para uso fuera de carreteras nueva P gina 22 Espa ol BLACK MAX 3650 WATT GENERATOR Generador 3 650 watts BM903655DA OPERATOR S MANUAL MANUAL DEL OPERADOR CALIFORNIA PROPOSITION 65 WARNING This product its exhaust and other substances that may become airborne from its use may contain chemicals including lead known to the State of California to cause cancer birth defects or other reproductive harm Wash hands after handling CALIFORNIA PROPUESTA DE LEY NUM 65 ADVERTENCIA Este producto su escape y otras sustancias que puedan llegar a ser aerotransportadas por su uso pueden contener sustancias qu micas por ejemplo plomo consideradas por el estad
68. l immediately to avoid equipment damage Always check the requirements of the tool or appliance being used compared to the rated output of the generator Motor Size H P Running Watts 3 Universal Capacitor Split Phase Oo w i 600 850 2050 a n 60m 1000 1800 360m o aa tO 1100 3300 BY NOTICE Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator Damage may result if the equipment is not designed to operate within a 10 voltage variation and 3 hz frequency variation from the generator name plate ratings To avoid damage always have an additional load plugged into the generator if solid state equipment such as a television set is used A power line conditioner is recommended for some solid state applications Page 8 English ELECTRICAL GENERATOR CAPACITY Make surethe generator can supply enough continuous run ning and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the continuous running watts of these items This NOTICE Do not overload the generator s capacity Exceeding the generator s wattage amperage capacity may damage the generator and or electrical devices connected to it is the amount of power the generator must produce to Estimated keep the it ing See the wa
69. l line e Fuel line fittings f Clamps 2 Air Induction System including a Intake pipe manifold b Air cleaner 3 Ignition System including a Spark plug b Ignition coil 4 Catalytic Muffler Assembly including a Muffler gasket b Exhaust manifold c Catalytic converter 5 Crankcase Breather Assembly including a Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Carbon canister c Canister mounting brackets d Fuel cap 7 Miscellaneous Items Used in Above Systems including a Switches b Hoses belts connectors and assemblies 8 Air Injection System a Pulse valve The warranty is provided in accordance with the U S EPA Emission Control Warranty Statement Page 21 English WARRANTY OWT INDUSTRIES INC FEDERAL EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The U S EPA Environment Canada and OWT Industries Inc are pleased to explain the evaporative emission control system s warranty on your small off road equipment New equipment that uses small off road engines must be designed built and equipped to meet the stringent evaporative standards OWT Industries Inc must warrant the evaporative emission control system on your small off road equipment for the period listed below provided there has been no abuse neglect or improper maintenance of your equipment Your evaporative emission control sy
70. la posici n ON ENCENDIDO m Desplace izquierda de la palanca del anegador hasta la posici n START ARRANQUE NOTA Si el motor est caliente o la temperatura es superior a los 10 C 50 F desplace derecha la palanca del anegador de la posici n RUN FUNCIONAMIENTO EH Lleveelinterruptor del motora la posici n de ENCENDIDO E Tiredel mango del arrancador retr ctil hasta que comience a funcionar el motor seis veces como m ximo NOTA Nopermita que el mango seretraiga violentamente despu s de arrancar regr selo suavemente a su lugar original E Permita que elmotor funcione 15 a 30 segundos y despu s desplace derecha la palanca del anegador en la posici n RUN FUNCIONAMIENTO APAGADO DEL MOTOR Vea las figuras 10 y 12 Para apagar el motor en condiciones normales de funcionamiento m Desconecte del generador toda carga presente E Ponga la v lvula de combustible en la posici n OFF APAGADO NH Lleve el interruptor del motor a la posici n de APAGADO 0 Para apagar el motor en una situaci n de emergencia NH Lleve el interruptor del motor a la posici n de APAGADO 0 A ADVERTENCIA Tanto en funcionamiento como al guardarlo mantenga siempre 91 4 cm 3 pies de espacio libre en todos los laterales de este producto incluida la parte superior Aguarde al menos 30 minutos para el equipo se enfrie antes de guardarlo El calor generado por el silenciador y los gases de escape puede ser suficient
71. lackmaxtools com or call toll free 1 800 726 5760 to locate your nearest manufacturer authorized BLACKMAX generator service facility for warranty and non warranty service on this BLACKMAX generator OWT Industries Inc P O Box 35 Highway 8 Pickens SC 29671 Page 20 English WARRANTY U S EPA EMISSIONS CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The U S Environmental Protection Agency EPA and Chongqing Dajiang Power Equipment Co Ltd are pleased to explain the emissions control system warranty on your small off road engine SORE U S EPA new SOREs must be designed built and equipped to meet the State s stringent anti smog standards Chongqing Dajiang Power Equipment Co Ltd must warrant the emissions control system on your SOREs for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your SOREs Your emission control system may include parts such as the carburetor fuel tanks fuel caps fuel lines the ignition system and catalytic converter Also included may be hoses belts clamps connectors and other emission related assemblies Where a warrantable condition exists Chongqing Dajiang Power Equipment Co Ltd will repair your small off road engine at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE The emissions control system is warranted for two years If any emissions related part on your engine
72. las conexiones de mangueras Inspeccione la respirador del vapor del tanque de combustible si est instalada Inspeccione el dep sito de carb n nicamente modelos CARB 1 Estas tareas deben ser efectuadas s lo por el centro de servicio autorizado 2 Consulte el manual del motor para conocer el cronograma de mantenimiento de este elemento NOTA La frecuencia de mantenimiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento de acuerdo con los intervalos all recomendados P gina 18 Espa ol CORRECCI N DE PROBLEMAS PROBLEMA CAUSA POSIBLE SOLUCI N El motor no arranca Le falta potencia al motor No funciona el recept culo de corriente alterna El generador produce un ruido como de cascabeleo o explosiones El interruptor del motor est en apagado OFP No hay combustible Gasolina rancia o agua rancia en la gasolina Est bajo el nivel de lubricante Est cerrada la v lvula de combustible OFP Buj a defectuosa sucia o con separaci n incorrecta La palanca de anegador est en la posici n RUN FUNCIONAMIENTO El motor almacenado sin tratamiento ni vaciado de gasolina o reabastecido de gasolina de mala calidad Filtro de combustible sucio Est sucio el filtro de aire El motor almacenado sin tratamiento ni vaciado d
73. le phase 60 Hz outlets two 120 V AC 20 amp receptacles one 120 VAC 30 amp twist lock receptacle and one 120 V AC 30 amp RV receptacle These can be used for operating appropriate appliances electrical lighting tools and motor loads RECOIL STARTER GRIP The recoil starter grip is used along with the engine switch to start the generator s engine Page 10 English ASSEMBLY UNPACKING This product requires assembly NW Carefully cut the box down the sides then remove the machine and any accessories from the box Make sure that all items listed in the packing list are included NOTE This machine is heavy and requires a minimum of two people to lift To avoid back injury lift with your legs and not your back WARNING Do not use this product if any parts on the Loose Parts List are already assembled to your product when you unpack it Parts on this list are not assembled to the product by the manufacturer and require customer instal lation Use of a product that may have been improperly assembled could result in serious personal injury WN Inspect the unit carefully to make sure no damage oc curred during shipping E Do not discard the packing material until you have carefully inspected and satisfactorily operated the product E If any parts are damaged or missing please call customer service for assistance A WARNING If any parts are damaged or missing do not operate this product until the pa
74. lectrical overload The circuit breaker may be reset by pressing the circuit breaker reset button AIR FILTER The air filter helps to limit the amount of dirt and dust drawn into the unit during operation CHOKE LEVER The choke lever is used when starting the engine DIGITAL DISPLAY The digital display shows AC voltage output frequency how long the engine has been running during the current usage period and the total number of hours the unit has been used FUEL TANK The fuel tank has a capacity of 4 gallons FUEL VALVE Fuel flow from the fuel tank to the engine is turned on and off using the fuel valve Rated Running Watts 3 650 W Rated Starting Watts 4 550 W Rated Frequentes id 60 Hz DIMENSIONS A a 24 in Wide 17 in A Niece 18 in A SR en ue ce 105 Ibs GROUND TERMINAL The ground terminal is used to assist in properly ground ing the generator to help protect against electrical shock Consult with a local electrician for grounding requirements in your area OIL CAP DIPSTICK Remove the oil cap dipstick to check and add lubricant to the generator when necessary LOW LUBRICANT SENSOR The engine will automatically shut off whenever the lubricant level in the engine becomes low OIL DRAIN PLUG When changing the engine lubricant the oil drain plug is removed to allow old engine lubricant to be drained RECEPTACLES Your generator has the following sing
75. medio del bastidor Utilice las tecnicas apropiadas de izado para evitar lesiones en la columna traves del agujero de montaje de la rueda E Coloque la tuerca en el perno y aj stela correctamente NW Para instalar la segunda rueda para el otro lado repita el procedimiento INSTALACI N DEL ABRAZADERA DEL MANGO Vea la figura 5 NH Localice los siguientes art culos Abrazadera del mango 2 Pernos 1 4 20 x 1 5 pulg 2 Tuerca de bloqueo 1 4 20 NW Ubique la abrazadera del mango en el armaz n del generador del lado del arrancador retr ctil E Haga pasar los pernos 1 4 20 x 1 5 mm por los agujeros de la abrazadera del mango y el armaz n del generador Coloque la tuerca de bloqueo y aj stela firmemente P gina 12 Espa ol FUNCIONAMIENTO A ADVERTENCIA No utilice ning n aditamento o accesorio no recomendado A PELIGRO Monoxido de carbono Usar un generador en el interior LO MATARA EN POCOS MINUTOS Los gases de escape del generador contienen niveles altos de monoxido de carbono CO un gas venenoso que no puede verse ni olerse Si puede oler los gases de escape del generador esta respirando CO Pero incluso Si no puede oler los gases de escape es posible que este respirando CO m Nunca use un generador dentro de su hogar garaje sotano ni demas espacios parcialmente encerrados En dichos espacios pueden acumularse niveles mortales de monoxido de carbono Usar un ventilador o abrir puertas y vent
76. mpiar el generador El agua que entra al sistema de combustible u otras partes internas puede causar problemas que acortan la vida de servicio del generador Para limpiar la unidad E Conun cepillo de cerdas suaves y o una aspiradora afloje y elimine la tierra y la basura m Limpielas aberturas de ventilaci n con aire a baja presi n que no se exceda de 25 psi m Limpie las superficies exteriores del generador con un pa o h medo REVISI N Y LIMPIEZA DEL FILTRO DE AIRE Vea la figura 14 Para obtener un desempe o apropiado y una larga vida til de la unidad mantenga limpios los filtro de aire E Afloje la perilla ubicados en la parte inferior de la tapa del filtro de aire Retire la tapa y h gala a un lado E Retire el filtro de aire E Retire la empaquetadura del filtro Limpie con un pa o limpio y reemplace la unidad de filtro de aire NH Si el filtro de aire est n sucios limpie el filtro con agua jabonosa tibia Enjuague el filtro de aire y d jelo secar completamente E Aplique una capa delgada de lubricante a filtro de aire y despu s estruje para sacar aqu l WE Vuelva a instalar el filtro de aire E Vuelva a colocar la tapa del filtro de aire y apriete la perilla para asegurarla NOTA No ponga a funcionar el generador sin los filtro de aire o junta Se causa un desgaste acelerado del motor CAMBIO DEL LUBRICANTE DEL MOTOR Vea la figura 15 NH Retire la tapa de relleno de aceite varilla medidora d
77. n estrictas normas para brindar fiabilidad facilidad de uso y seguridad para el operador Con el debido cuidado le brindar muchos anos de s lido y eficiente funcionamiento A ADVERTENCIA Para reducir el riesgo de lesiones el usuario debe leer y comprender el manual del operador antes de usar este producto Guarde este manual del operador y estudielo frecuentemente para lograr un funcionamiento seguro y continuo de este producto GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS See this fold out section for all of the figures referenced in the operator s manual Consulte esta secci n desplegable para ver todas las figuras a las que se hace referencia en el manual del operador A Recoil starter grip mango del arrancador retr ctil B Air filter filtro de aire C Choke lever palanca del anegador D Fuel cap tapa del tanque E Fuel tank tanque de combustible F 120 volt AC 20 amp receptacles 120 V de CA 20 A recept culos G 120 Volt 30 Amp RV receptacle toma recept culo por veh culos recreativos de 120 V 30 A H 30 amp AC circuit breaker 30 A disyuntor de circuito de CA Engine switch interruptor del motor J Digital display pantalla digital 8 ga e mu E gt A A Socket wrench llave de casquillo B Combination wrench llave de combinaci n K Oil drainage bolt perno de drenaje de aceite L Oil cap dipstick tapa de relleno de aceite varilla medidora de ace
78. n virtud de la garant a debe ser garantizada por un periodo no inferior al tiempo al primer punto de reemplazo programado para la pieza 4 La reparaci n o reemplazo de cualquier pieza garantizada en virtud de las restricciones de la garant a de este art culo debe ser realizada sin cargo al propietario en la estaci n de garant a 5 No obstante de las restricciones de la subsecci n 4 anteriormente citada los servicios o reparaciones de garant a debe ser proporcionados en los centros de distribuci n que son franquiciados para dar servicio a los motores o equipos sujetos 6 No debe haber cargo para el propietario por la mano de obra de diagn stico que determina el que una pieza garantizada est defectuosa siempre y cuando dicho diagn stico sea realizado en una estaci n de garant a Durante todo el tiempo de la garant a del sistema de control de emisi n evaporativa fijada en la subsecci n b 2 el fabricante que expide la garant a debe mantener un suministro suficiente de piezas garantizadas para cumplir con la demanda esperada para dichas piezas 8 Las piezas de repuesto aprobadas por el fabricantes deben ser utilizadas en la realizaci n de cualquier mantenimiento o reparaciones de garant a y deben ser proporcionadas sin costo al propietario Tal uso no reducir las obligaciones de la garant a del fabricante que expide la garant a E El uso de piezas modificadas o a adidas seramotivo para no perm
79. nce or repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of the manufacturer issuing the warranty 9 The use of any add on or modified parts will be grounds for disallowing a warranty claim made in accordance with this article The manufacturer issuing the warranty will not be liable under this Article to warrant failures of warranted parts caused by the use of an add on or modified part EMISSION WARRANTY PARTS LIST 1 Fuel Tank 2 Fuel Cap Fuel Line Carbon Canister o A Vapor Hoses Hose Clamps N O Hose Connectors 8 Vapor Fuel Check Valve Written instructions for the maintenance and use of the evaporative emissions control system by the owner shall be furnished with all new small off road equipment English NDICE DE CONTENIDO E MITO UCA A A A A onde to hair 2 Instrucciones de segundad IMPORantes aia 3 4 m Reglas de seguridad especia den tan ina e RN 4 m SM 610 110 A e ene 5 7 m ASDECIOS elect COS ii io 8 9 m o O72 0216 9 5101072 Lo ISORA PORRA CO po A 10 A 11 12 FUNCIONA MIO NO ern a a e EEE ES 13 15 E Ma tenimientos a E a A 16 18 m Corecclonmde DIObDI MAS ii A A E E 19 me GA AAN T E O O TA atlas rd neared haya a cata a 20 22 E Pedidos de pi zas A O E AA O P g posterior INTRODUCCI N Este producto ofrece numerosas caracter sticas que hacen el uso del mismo m s placentero y agradable En el dise o
80. nch All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be Double Insulated It is recommended to 1 Use electrical devices with 3 prong grounded plugs 2 Use an extension cord intended for outdoor use with a 3 pole receptacle and a 3 prong plug at opposite ends to ensure continuity of the ground protection from the generator to the appliance Check and adhere to all applicable federal state and local regulations relating to grounding specifications Consult a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the generator is properly grounded Page 2 English IMPORTANT SAFETY INSTRUCTIONS DANGER Carbon Monoxide Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains high levels of carbon mon oxide CO a poisonous gas you cannot see or smell If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO m Never use a generator inside homes garages crawl spaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in generator exhaust Even when y
81. ndido A Move choke lever left to start desplace derecha de la palanca del anegador para arrancar B Move choke lever right to run desplace derecha de la palanca del anegador para marcha A Engine switch valvula de combustible B Off apagado C On encendido Fig 13 A Select button bot n de selecci n Fig 14 B A Ys Knob perilla Air filter cover tapa del filtro de aire Air filter filtro de aire Deflector deflector Air filter unit unidad del filtro de aire Fig EZ P e A Oil drainage bolt perno de drenaje de aceite B Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite m o o uy D gt ee A A Spark plug bujia B Spark plug cap tapa de la buj a A Screw tornillo B Muffler outlet recubrimiento del silenciador C Spark arrestor parachispas D Wire brush cepillo de alambre A Fuel line conducto de combustible B Fuel valve valvula de combustible C Petcock llave de purga D Off apagado E On encendido Fig 19 Ca SERES TES FRET TA gt A Carburetor drain screw tornillo de drenaje del carburador Fig 20 A Fuel line conducto de combustible B Fuel filter filtro de combustible TABLE OF CONTENTS m LE 100 UT o 0 y COPPER OOOO o O ass anna nensaeaveaun E eee haa eae ee A ON 2 Importantsate ASTUCIA Sc 3 4 a Specilic sate RUGS tonto coc
82. nectar a trav s de un interruptor de transferencia que controla todos los conductores excepto el conductor de conexi n a tierra del equipo El bastidor del generador debe conectarse a un electrodo de conexi n a tierra aprobado Si no se a sla el generador de las l neas de alto voltaje puede causarse la muerte o lesiones a los trabajadores de dichas l neas NO utilice este generador para suministrar energ a a dispositivos de soporte vital o equipos m dicos de emergencia Este generador tiene un punto neutro conectado a tierra Esto quiere decir que la tierra del sistema se conecta el ctricamente al cable neutro de CA Lasemanaciones delescape contienen mon xido de carbono un gas t xico incoloro e inodoro La inhalaci n de las emanaciones del escape puede causar la p rdida de la conciencia e incluso la muerte Si se utiliza la unidad en un rea total o parcialmente cerrada el aire puede contener una cantidad peligrosa de mon xido de carbono Para evitar la acumulaci n de las emanaciones del escape siempre aseg rese de que que haya ventilaci n suficiente Siempre use un detector de mon xido de carbono de bater as al utilizar el generador Si comienza a sentirse mal mareado o d bil al estar utilizando el generador ap guelo y respire aire fresco de inmediato Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono Coloque el generador en una superficie estable horizontal con una pendiente no mayor de 4
83. nerator please follow the maintenance schedule provided in the en gine manual instead of the maintenance information listed below Before After 1st month Every 3 months Every 6 months Every year or or 20 hours of or 50 hours of or 100 hours after 300 hours each use i i operation operation of operation of operation Check ao Lubricant Change Engine Lubrican ee Check Air Fiter Clean Air Fiter Change Air Fite J PP Check Adjust Spark Plug J o o o oo poesta oe eeaeee QA y Check Adjust Idle Speed J Check Adjust Valve Clearance Clean Fuel Tank and Filter i 7 Wn Check Fuel Hose RE a a a S E yO replace er All Hose Connections Inspect Fuel Tank Vapor Vent If Equipped Inspect Carbon Canister CARB Models Only 1 These items should only be carried out by an authorized service center 2 See engine manual for maintenance schedule for this item NOTE Maintenance should be performed more frequently when generator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein Page 18 English TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine will not start Engine switch is OFF Turn engine switch to ON No fuel Fill fuel tank Stale gasoline or water in gasoline Drain entire system and refill with fresh fuel Lubricant level is low Check eng
84. nimiento a los motores en cuesti n 6 No se deber cobrar al propietario del motor ninguna tarea de diagn stico que se realice para determinar si una pieza cubierta por la garant a est de hecho defectuosa siempre y cuando dicha tarea de diagn stico se realice en una estaci n designada 7 Chongqing Dajiang Power Equipment Co Ltd es responsable por los da os a otros componentes del motor causados directamente por una falla de cualquier pieza cubierta por la garant a durante la vigencia de esta 8 Alo largo del per odo de garant a indicado m s arriba Chongqing Dajiang Power Equipment Co Ltd mantendr un suministro de piezas garantizadas suficiente para cubrir la demanda esperada de dichas piezas 9 Cualquier repuesto que sea usado en la realizaci n de cualquier trabajo de mantenimiento o reparaci n cubierto por la garant a deber proveerse sin cargo para el propietario Dicho uso no reduce las obligaciones de garant a de Chongaing Dajiang Power Equipment Co Ltd 10 No podr n usarse complementos ni piezas modificadas que no hayan sido marcados como excepciones por la Junta de Recursos del Aire El uso por parte del comprador final de cualquier complemento o pieza modificada que no haya sido marcada como excepci n podr usarse como argumento para rechazar reclamaciones de garant a Chongqing Dajiang Power Equipment Co Ltd no ser responsable de garantizar fallas de piezas bajo garant a que sean causada
85. no Si observa alguna p rdida de potencia en la productos con motor de gasolina quiz sea necesario eliminar dichos dep sitos para restablecer el desempe o original Recomendamos enf ticamente que este servicio lo realicen nicamente t cnicos de servicio calificados PARACHISPAS Vea la figura 17 Es necesario limpiar o reemplazar el parachispas cada 50 horas o anualmente para asegurarse del buen funcionamiento de la unidad Los parachispas pueden estar instalados en diferentes posiciones dependiendo del modelo del cual se trate Comun quese con el establecimiento de servicio m s cercano para confirmar la ubicaci n del parachispas para su modelo espec fico Para limpiar el parachispas WN Quite las tuercas que mantienen el parachispas en su lugar H Quite el parachispas y limpielo suavemente con un cepillo de alambre E Vuelva a colocar el parachispas y asegurelo con los tornillos DRENAJE DEL TANQUE DEL COMBUSTIBLE Y DEL CARBURADOR Vea las figuras 18 y 19 Para evitar los dep sitos de sustancias gomosas en el sistema de combustible vac e el tanque de combustible y el carburador antes de guardarlo DRENAJE DEL TANQUE DE COMBUSTIBLE E Ponga el interruptor del motor en OFF APAGADO E Ponga la v lvula de combustible en la posici n OFF APAGADO E Retire el conducto de combustible de la llave de purga para ello apriete los extremos del sujetador de retenci n y separe el conducto NW Instale un extr
86. ntinuaci n BlackMax www blackmaxtools com 1 866 340 3912 COBERTURA DE LA GARANT A CONTRA DEFECTOS Conforme a lo dispuesto por la Junta de Recursos del Aire Chongqing Dajiang Power Equipment Co Ltd garantiza al comprador final y a cualquier comprador sucesivo que el motor peque o para veh culos todo terreno SORE 1 ha sido dise ado construido y equipado para cumplir con todas las normativas pertinentes y 2 est libre de defectos en los materiales y la fabricaci n que puedan causar la falla de una pieza bajo garant a de acuerdo con las normativas que se apliquen a los t rminos y condiciones indicados a continuaci n a El per odo de garant a comienza en la fecha en la que se entrega el motor a un comprador final o la primera vez que se lo lleva a servicio t cnico El per odo de garant a es de dos a os b Sujeta a ciertas condiciones y exclusiones seg n se indica a continuaci n la garant a sobre las piezas relacionadas con las emisiones tiene los siguientes t rminos 1 Cualquier pieza cubierta por la garant a que no tenga programado un cambio como parte del mantenimiento obligatorio en su manual del operador tiene garant a por el per odo de garant a indicado m s arriba Si la pieza falla durante el per odo de cobertura de la garant a dicha pieza ser reparada o cambiada por Chongqing Dajiang Power Equipment Co Ltd de acuerdo con la Subsecci n 4 m s abajo Cualquiera de dichas piezas qu
87. o El generador es una fuente potencial de descarga el ctrica No lo exponga a humedad la lluvia nin a la nieve No opere con manos o pies h medos El escape contiene gas venenoso de mon xido de carbono que puede causar p rdida del conocimiento a la MUERTE Opere en reas exteriores bien ventiladas lejos de puertas o ventanas abiertas 44 DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell Rd WO Ji gt Only use OUTSIDE and far away from windows doors and vents NEVER use inside a home oF garage EVEN IF doors and windows are open 940654112 03 ventiladaslejos de puertas o ventanas abiertas Failure to properly ground generator can result in electrocution especially if the generator is equipped with a wheel kit E La omisi n de conectar a tierra adecuadamente el generador puede resultar en electrocuci n especialmente si el generador est a equipado con un kit de ruedas No exponga la unidad a la lluvia ni la use en lugares h medos Usar un generador en el interior PUEDE MARTARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno que no puede verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo utilicelo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos 44 PELIGRO Usar un generado
88. o 940708006 03 the dipstick The unit is equipped witha nsor which will automaticall le E a atically shut off o A WARNING HE o SS the engine if the lubricant level falls below a safe limit around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements SPARK ARRESTOR 3 q oe 1 l l ADVERTENCIA El uso de este equipo puede producir chispas propensas a Operation of this equipment may create sparks that can start PE OR OS pas El operador debe ponerse en contacto con las agencias contra incendios locales fires around dry vegetation A spark arrestor mmay be required para conocer las leyes y regulaciones relacionadas con los requisitos de prevenci n The operator should contact local fire agencies for laws or RAGE 940947006 01 regulations relating to fire prevention requirements GROUNDING WARNING WARNING HOT SURFACE National Electric Code requires generator to be grounded to an approved earth ground 44 ADVERTENCIA SUPERFICIES CALIENTE 940680040 02 WARNING ADVERTENCIA Product does not include ground rod or copper wire National Electric Code requires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements HOT SURFACE WARNING Do not touch the muffler or aluminum cylin El producto no incluye el alambre de cobre ni la barra de conexi
89. o de California como causantes de c ncer defectos de nacimiento u otras alteraciones reproductivas L vese las manos despu s de utilizar el aparato SERVICE For parts or service contact your nearest Black Max authorized service dealer Be sure to provide all relevant information when you call or visit For the location of the authorized service dealer nearest you please call 1 800 726 5760 REPAIR PARTS The model number of this product is found on a plate or label attached to the housing Please record the serial number in the space provided below MODEL NO SERIAL NO SERVICIO Para obtener piezas o servicio comun quese con el centro de servicio autorizado de Black Max m s cercano Aseg rese de proporcionartodos los datos pertinentes al llamar o al presentarse personalmente Para obtener informaci n sobre el establecimiento de servicio autorizado m s cercano a usted le suplicamos llamar al 1 800 726 5760 PIEZAS DE REPUESTO El n mero de modelo de este producto se encuentra en una placa o etiqueta pegada a la caja del motor Le recomendamos anotar el n mero de serie en el espacio suministrado abajo N MERO DE MODELO N MERO DE SERIE OWT INDUSTRIES INC P O Box 35 Highway 8 Pickens SC 29671 USA 1 800 726 5760 www blackmaxtools com 990000408 2 11 13 REV 01
90. o no incluye el alambre de cobre ni la barra de conexi n a tierra Los Reglamentos Nacionales de Electricidad exigen que el generador est debidamente conectado a una tierra aprobada Comuniquese con un electrista para todo lo relacionado con los requistos de conexi n a tierra 940513013 00 ADVERTENCIA DE SUPERFICIE CALIENTE ADVERTENCIA DE ESPACIO LIBRE No toque el silenciador ni el cilindro de aluminio del motor Est n muy CALIENTES y causan quemaduras graves No ponga ning n material inflamable o combustible directamente en la trayectoria de las emanaciones del escape Tanto en funcionamiento como al guardarlo mantenga siempre 91 4 cm 3 pies de espacio libre en todos los laterales de este producto incluida la parte superior Aguarde al menos 30 minutos para el equipo se enfr e antes de guardarlo El calor generado por el silenciador y los gases de escape puede ser suficiente para causar quemaduras graves y o prender fuego a objetos combustibles P gina 7 Espa ol ASPECTOS EL CTRICOS CALIBRE DEL CORD N DE EXTENSI N Consulte el cuadro mostrado abajo para asegurarse de que el calibre de los cordones de extensi n que utilice puedan con la carga el ctrica requerida Los cordones de calibre insuficiente pueden causar una ca da de voltaje lo cual puede da o el dispositivo y recalentar el cord n mismo Corriente en Longitud m xima permitida del cord n Amperios 25 30m f 805 m 1000 pies 183 m 600 pies
91. ou use a generator correctly CO may leak into the home ALWAYS use a battery powered or bat tery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You could have carbon monoxide poisoning WARNING Read and understand all instructions Failure to follow all instructions listed below could result in electrocution fire and or carbon monoxide poisoning which can cause death or serious injury A DANGER National Electric Code requires generator to be grounded to an approved earth ground Before using the ground ter minal consult a qualified electrician electrical inspector or local agency having jurisdiction for local codes or or dinances that apply to the intended use of the generator SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the genera tor and batteries m Do not connect to a building s electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes E Do not allow children or untrained individuals to use this unit Do not start or operate the engine in a confined space building near open window
92. ows are open Risk of fire Do not add fuel while the product is operating Riesgo del incendio No agregue combustible cuando el producto est functionando DANGER A PELIGRO You WILL be KILLED or SERIOUSLY HURT if you do not follow the Operator s Manual instructions SE MATAR o LESIONAR GRAVEMENTE si no sigue las instrucciones del Manual del operador 9972 Exhaust contains poisonous carbon monoxide gas Git that can cause unconsciousness or DEATH Operate gt PE Z in well ventilated outdoor areas away from open windows or doors El escape contiene gas venenoso de mon xido de carbono que puede causar p rdida del conocimiento o MUERTE Opere en reas exteriores bien ventiladaslejos de puertas o ventanas abiertas Failure to properly ground generator can result in electrocution especially if the generator is equipped with a wheel kit La omisi n de conectar a tierra adecuadamente el generador puede resultar en electrocuci n especialmente si el generador est equipado con un kit de ruedas Do not expose to rain or use in damp locations No exponga a la lluvia ni use en lugares h medos 940654112 03 E Failure to properly ground generator can result in elec trocution especially if the generator is equipped with a wheel kit Do not expose to rain or use in damp locations Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you
93. parato en vatios adicional en vatios Acondicionador de aire de ventana 1200 1800 10000 BTU Refrigerador 700 2200 Bomba de pozo de 1 3 HP 1000 2000 Televisor de 27 pulg 0 Iluminaci n 75 vatios 0 3475 vatios 2200 vatios potencia en potencia arranque marcha total m xima Potencia continua total en vatios 3475 Potencia arranque m xima en vatios 2200 Potencia arranque m xima en vatios 5675 ADMINISTRACI N DE LA POTENCIA A fin de prolongar la vida til del generador y los dispositivos acoplados esimportantetener cuidado al agregar cargas el ctricas al generador NO debe haber equipo alguno conectado a los tomacorrientes del generador antes de poner en marcha el motor respectivo La manera correcta y segura de administrar la potencia del generador consiste en agregar las cargas de manera secuencial de la manera siguiente 1 Sin equipos conectados al generador ponga en marcha el motor de la manera que se describe posteriormente en este manual 2 Enchufe y active la primera carga preferiblemente la m xima carga que tenga 3 Deje que se estabilice la salida del generador el motor marcha uniformemente y el dispositivo acoplado funciona correctamente 4 Enchufe y active la siguiente carga 5 Nuevamente deje que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional Nunca a ada m s cargas que las que permita la capacidad del generador Tenga especial cuidado al considerar las cargas de so
94. quipment Co Ltd tienen el agrado de explicar la garant a del sistema de control de emisiones del motor peque o para veh culos todo terreno Small Off Road Engine SORE Los motores SORE nuevos que cumplan con lo estipulado por la EPA de EE UU deben dise arse fabricarse y equiparse de manera que cumplan con las rigurosas normas estatales contra la contaminaci n del aire Chongqing Dajiang Power Equipment Co Ltd debe garantizar el sistema de control de emisiones de sus motores SORE en los per odos de tiempo que se indican a continuaci n siempre que los motores SORE no hayan sufrido un uso incorrecto negligencia o mantenimiento inadecuado El sistema de control de emisiones puede incluir piezas como el carburador los tanques de combustible los tapones de los tanques de combustible las l neas de combustible el sistema de encendido y el convertidor catal tico Tambi n puede incluir mangueras correas abrazaderas conectores y otros conjuntos relacionados con las emisiones Cuando se presente una situaci n contemplada por la garant a Chongqing Dajiang Power Equipment Co Ltd reparar su motor peque o para veh culos todo terreno sin costo incluyendo el diagn stico las piezas y la mano de obra COBERTURA DE LA GARANT A DEL FABRICANTE El sistema de control de emisiones est garantizado por dos a os Si cualquiera de las piezas relacionadas con el motor presenta alg n defecto ser reparada o reemplazada por Chongqin
95. quipment should be checked prior to plug ging them into this generator Damage may result if the equipment is not designed to operate within a 10 voltage variation and 3 hz frequency variation from the generator name plate ratings To reduce the risk of damage always have an additional load plugged into the generator if solid state equipment such as a television set is used A power line conditioner is recommended for some solid state applications Never operate the generator without a spark arrestor screen For outdoor use only Save these instructions Refer to them frequently and use them to instruct others who may use this product If you loan someone this product loan them these instructions also Page 4 English SYMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product SYMBOL SIGNAL MEANING Indicates an imminently hazardous situation which if not avoided will result in death or serious injury DANGER Indicates a potentially hazardous situation which if not avoided could result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates important information not related to an injury hazard such as a situation that may result in property damage NOTICE Some of the following symbols may be us
96. r en el interior PUEDE MATARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno que no puede verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos P gina 6 Espa ol S MBOLOS ADVERTENCIA DE COMBUSTIBLE No fume al abastecer el combustible No DANGER PELIGRO llene de mas El nivel de lleno es 25 mm 1 pulg debajo del cuello del tanque de combustible Pare la marcha del motor cinco minutos antes del reabastecimiento de combustible para evitar que el calor del silenciador encienda los vapores de combustible ADVERTENCIA DEL LUBRICANTE DE MOTOR Riesgo de incendio Revise si hay alg n derrame o fuga de combustible Apaque el motor antes de poner combustible Risk of Fire Check for any fuel overflow or leaking Stop the engine before refueling 940974004 01 Antes de utilizar el generador debe abastecerlo de Add lubricant to full mark to start Engine will not start or lubricante Antes de utilizarla unidad revise el nivel de will shut off if lubricant is too low lubricante El nivel de lubricante siempre debe estar Agregue lubricante hasta la marca de lleno para arrancar El z motor no arrancara 0 se apagara SI el nivel de lubricante entre las reas cubierta con rayas entrecruzadas de est demasiado bajo pee
97. retation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION a to Y umes SSCS SAFETY LABELS The information on this page can be found on the generator For your safety please study and understand all of the labels before starting the generator If any of the labels come off the unit or become hard to read contact an authorized service center for replacement Generator is a potential source of electric shock Do not expose to moisture rain or snow Do not operate with wet hands or feet El generador es una fuente de descarga el ctrica No lo exponga a humedad la lluvia nin a la nieve No opere con manos o pies h medos You WILL be KILLED or SERIOUSLY HURT if you do not follow the Operator s Manual instructions Risk of Fire Do not add fuel while the product is operating Generator is a potential source of electric shock Do not expose to moisture rain or snow Do not operate with wet hands or feet Exhaust contains poisonous carbon monoxide gas that can cause unconsciousness or DEATH Operate in well ventilated outdoor areas away from open windows or doors DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell Only use OUTSIDE and far away from windows Y respiraderos doors and vents NEVER use inside a home or garage EVEN IF doors and wind
98. ro de servicio autorizado para obtener un reemplazo Generator is a potential source of electric shock Do not expose to moisture rain or snow Do not operate with wet hands or feet El generador es una fuente de descarga el ctrica Risk of fire Do not add fuel while the product is operating Riesgo del incendio No agregue combustible cuando el producto est functionando DANGER A PELIGRO You WILL be KILLED or SERIOUSLY HURT if you do not follow the Operator s Manual instructions SE MATAR o LESIONAR GRAVEMENTE si no sigue las instrucciones del Manual del operador AP Exhaust contains poisonous carbon monoxide gas AY that can cause unconsciousness or DEATH Operate gt SA Z in well ventilated outdoor areas away from open A windows or doors a O El escape contiene gas venenoso de mon xido de carbono que puede causar p rdida del conocimiento o MUERTE Opere en reas exteriores bien La omisi n de conectar a tierra adecuadamente el generador puede resultar en electrocuci n especialmente si el generador est equipado con un kit de ruedas Do not expose to rain or use in damp locations No exponga a la lluvia ni use en lugares h medos No lo exponga a humedad la lluvia nin a la nieve No opere con manos o pies h medos SE MATAR o LESIONAR GRAVEMENTE si no sigue las instrucciones del Manual del operador Riesgo de incendio No agregue combustible cuando el producto est functionand
99. rts are replaced Use of this product with damaged or missing parts could result in serious personal injury A WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious per sonal injury A WARNING Do not attempt to operate the generator until assembly is complete Failure to comply could result in possible serious personal injury LOOSE PARTS LIST See Figure 2 The following items are included with the generator Key No Description Qty 4 LOCK N tS 1 4 Olano 7 2 ANN Sra 2 3 BORS 9 0 420 Mad 2 4 SUDDON Fee leisure tensnee ere 2 D Ml dais 1 G Spacer lat 2 E Handle BACK CPi vied saat ed 1 8 Bolts 1 4 20 x 1 5 IN ooccoccnccccncoconncncnnonanncnannnnns 7 9 Lock Nuts 3 6 16 iio 2 10 Bottle of Engine Lubricant 1 Operator s Manual not shown 1 TOOLS NEEDED See Figure 2A The following tools not included or drawn to scale are needed for assembly E Socket Wrenches and or Combination Wrenches NOTE Do not put fuel or lubricant in the generator before installing the feet and wheels INSTALLING FEET See Figure 3 m Raise the end of the generator where the recoil starter is located high enough to gain access to the frame bottom securely position props
100. s or in other unventilated space where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and extremely dangerous gas can cause unconsciousness or death Keep all bystanders children and pets at least 10 feet away Wear sturdy and dry shoes or boots Do not operate while barefoot Do not operate generator when you are tired or under the influence of drugs alcohol or medication Keep all parts of your body away from any moving parts and all hot surfaces of the unit Do not touch bare wire or receptacles Do not use generator with electrical cords which are worn frayed bare or otherwise damaged Before storing allow the engine to cool and drain fuel from the unit Do not operate or store the generator in rain snow or wet weather Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator Empty fuel tank close fuel valve and restrain the unit from moving before transporting in a vehicle Allow engine to cool for five minutes before refueling To reduce the risk of fire and burn injury handle fuel with care It is highly flammable Do not smoke while handling fuel Store fuel in a container approved for gasoline Position the unit on level ground stop engine and allow to cool before refueling Loosen fuel cap slowly to release pressure and to keep fuel from escaping around the cap Tighten the fuel cap secur
101. s por el uso de cualquier complemento o pieza modificada que no haya sido marcado como excepci n 11 El fabricante que emite la garant a deber proporcionar toda la documentaci n que describa los procedimientos o las pol ticas de garant a del fabricante en un plazo no mayor a los cinco d as h biles a partir de que se lo solicite la Junta de Recursos del Aire LISTA DE PIEZAS DE LA GARANT A DEL CONTROL DE EMISIONES La reparaci n o el cambio de cualquier pieza bajo garant a que cumpla con los dem s requisitos para recibir cobertura puede no recibir dicha cobertura si Chongqing Dajiang Power Equipment Co Ltd demuestra que el motor ha sido usado incorrectamente negligentemente o ha recibido mantenimiento inadecuado y que dicho uso incorrecto negligencia o mantenimiento inadecuado fueron causa directa de la necesidad de reparar o cambiar la pieza Sin perjuicio de ello cualquier ajuste sobre un componente que tenga un dispositivo de limitaci n de ajuste instalado de f brica y que funcione correctamente todav a cumple con los requisitos para recibir cobertura de la garant a Las siguientes piezas relacionadas con las emisiones tienen garant a para las familias de motores indicadas 1 Sistema de medici n de combustible a Conjunto del carburador de gasolina y sus componentes internos b Juntas del carburador c Tanque de combustible d Conducto de combustible e Accesorios del conducto del combustible f Pinzas 2
102. se emite mon xido de carbono un gas t xico incoloro e inodoro Si se inhala mon xido de carbono puede causarse n usea desmayo o la muerte El combustible y los vapores del mismo son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Para reducir el riesgo de lesiones corporales o da os materiales evite tocar toda superficie caliente Para reducir el riesgo de lesiones serias evite intentar levantar el generador usted solo Consulte a un electricista de la localidad para determinar los requisitos de conexi n a tierra antes de utilizar la unidad El incumplimiento de conectar correctamente a tierra el generador puede resultar en electrocuci n especialmente si el generador est equipado con un conjunto de disco P gina 5 Espa ol S MBOLOS Es posible que se empleen en este producto algunos de los siguientes s mbolos Le suplicamos estudiarlos y aprender su significado Una correcta interpretaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE DENOMINACI N EXPLICACI N oa oan on ETIQUETAS DE SEGURIDAD La siguiente informaci n puede encontrarse en el generador Para su propia seguridad le sugerimos estudiar y entender todas la etiquetas antes de poner marcha el generador Si se desprende de la unidad cualquiera de las etiquetas o se vuelven ilegibles comuniquese con alg n cent
103. servicio autorizado Si el problema persiste despu s de probar las soluciones mencionadas arriba comun quese con un centro de servicio autorizado para solicitar asistencia Los siguientes s ntomas pueden indicar problemas que afectan el nivel de emisiones de la unidad Arranque dif cil o paro del motor despu s de arrancar Marcha lenta irregular Combusti n secundaria combusti n retardada E E E Falla o retardo en la combusti n con la unidad bajo carga E A Sale humo negro del escape o consumo elevado de combustible Si encuentra cualquiera de estos s ntomas permita que inspeccionen y reparen la unidad en un centro de servicio autorizado P gina 19 Espa ol GARANT A BLACKMAX G N RATEUR GARANTIE LIMIT E Une preuve d achat doit tre pr sent e pourtoute demande de r paration sous garantie Ce produit est fabriqu par OWT Industries Inc Toutes les communications de garantie doivent tre adress es OWT Industries Inc aux soins de Services d Entretien de la G n rateur au 1 800 726 5760 appel gratuit CE QUI EST COUVERT PAR LA GARANTIE LIMITEE Ce g n rateur BLACKMAX est garanti au seul acheteur d origine tre exempt de vice du mat riau et de fabrication sous reserve de certaines exceptions et limitation indiqu es ci dessous au cours des p riodes indiqu es ci dessous a compter de la date d achat EH Dos 2 ans sur les produits utilis s uniquement par des p
104. ss than the remaining warranty period 3 Any warranted part that is scheduled for replacement as required maintenance in the written instructions must be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part must be repaired or replaced by the manufacturer issuing the warranty Any such part repaired or replaced under warranty must be warranted for a time not less than the remainder of the period prior to the first scheduled replacement point for the part 4 Repair or replacement of any warranted part under the warranty provisions of this article must be performed at no charge to the owner at a warranty station 5 Notwithstanding the provisions of subsection 4 above warranty services or repairs must be provided at distribution centers that are franchised to service the subject equipment 6 The owner must not be charged for diagnostic labor that leads to the determination that a warranted part is in fact defective provided that such diagnostic work is performed at a warranty station 7 Throughout the evaporative emission control system s war ranty period set out in subsection b 2 the manufacturer issuing the warranty must maintain a supply of warranted parts sufficient to meet the expected demand for such parts 8 Manufacturer approved replacement parts must be used in the performance of any warranty maintena
105. statales y locales Ponga una cucharada sopera de lubricante para motor en el cilindro de la buj a Gire el motor lentamente con la cuerda de tiro para distribuir el lubricante Instale de nuevo la buj a Cambie el lubricante del motor Al sacar la unidad despu s de haberla tenido guardada m Reabastezca de gasolina fresca la unidad NOTA Si guarda gasolina en un recipiente adecuado para utilizarla en otro momento aseg rese de que haya sido tratada con un estabilizador de combustible de acuerdo con las instrucciones del fabricante del estabilizador PROGRAMA DE MANTENIMIENTO NOTA Si recibe un manual del motor para este generador en particular respete el cronograma de mantenimiento que se indique en el manual del motor y no la informaci n de mantenimiento que figura a continuaci n Al cabo del Cada 3 meses Cada 6 meses Cada a o Antes de primer mes o o luego de o 50 horas de o 100 horas de cada uso 20 horas de funcionamiento funcionamiento 300 horas de funcionamiento funcionamiento Revisar el lubricante del motor a Cambiar ol ubricente del motor Revisar e1 fitro de aire Limpiar litro de aire Cambiar a fitro dear Comproberiejusterlabaja Reemplazar a buis Comprobar ajustarla velocidad de raient Comproberiejustarelhuelgo de v wuta EEE Limpiar el dep sito y el filtro de combustible Comprobar de manguera de combustible Reemplazo del filtro de combustible Inspeccione Compruebe todas
106. stem may include parts such as carburetors fuel tanks fuel line fuel caps valves canisters filters vapor hoses clamps connectors and other associated components MANUFACTURER S WARRANTY COVERAGE Thisevaporative emission control systemis warranted fortwo years Ifany evaporative emission related part on your equipment is defec tive the part will be repaired or replaced by OWT Industries Inc OWNER S WARRANTY RESPONSIBILITIES E As the small off road equipment owner you are responsible for performance of the required maintenance listed in your operator s manual OWT Industries Inc recommends that you retain all receipts covering maintenance on your small off road equipment but OWT Industries Inc cannot deny warranty solely for the lack of receipts E As the small off road equipment owner you should however be aware that OWT Industries Inc may deny you warranty coverage if your small off road equipment or a part has failed due to abuse neglect or improper maintenance or unapproved modifications m You are responsible for presenting your small off road equip ment to a OWT Industries Inc distribution center or service center as soon as the problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have a question regarding your warranty coverage you should contact OWT Industries Inc at 1 800 726 5760 DEFECTS WARRANTY REQUIREMENTS a
107. to the generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Take special care to consider surge loads in generator capacity as previously described Page 9 English FEATURES PRODUCT SPECIFICATIONS ENGINE ENGINE IW DC sereis aa e 208 cc OHV Replacement Spark Plug LG F7TC Engine Lubricant Volume 0 64 ats USI Vol resseccsens ences ceca eunes a a aa 4 gal GENERATOR Rated Vota aiii ios 120V Rated AMS en at diia 30 4 A Rated running watts determined by PGMA Standard G200 KNOW YOUR GENERATOR See Figure 1 The safe use of this product requires an understanding of the information on the product and in this operator s manual as well as a knowledge of the project you are attempting Before use of this product familiarize yourself with all operating features and safety rules AC CIRCUIT BREAKERS The circuit breakers are provided to protect the generator against e
108. ttage ref hart Estimated Additional eep the items running See the wattage reference char Application Equipment Running Adetona at right Watts Starting Watt 3 Estimate how many surge starting watts you will need lle Surge wattage is the short burst of power needed to Emergency Home Standby i aa start electric motor driven tools or appliances such as a Clock Radio circular saw or refrigerator Because not all motors start Lights qty 4 x 75 W 300 300 at the same time total surge watts can be estimated by 200 2200 adding only the item s with the highest additional surge 9 800 2350 watts to the total rated watts from step 2 Example Water Well Pump 1000 1500 Running Additional 1000 1000 Heer el ppilalice Watts Starting Watts Sump Pump 1050 2200 Window AC 1800 Electric Range per element 2100 10 000 BTU deb Se S Refrigerator 700 2200 Electric Drill 1 2HP 600 1 3 HP Well Pump 1000 2000 Arles Sprayer 18 H2 600 1200 Light 75 Watts 0 Reciprocating Saw 0 1920 3475 Total 2200 Highest 4500 Running Watts Starting Watts 2300 Total Running Watts 3475 1800 Highest Starting Watts 2200 1800 Total Starting Watts Needed 5675 2000 Wattages listed are approximate Check tool or appliance for actual wattage POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding electrical loads to the generator There should be nothing connected
109. ue os para el uso fuera de carreteras deben dise arse fabricarse y equiparse de manera que cumplan con las rigurosas normas contra la contaminaci n del aire OWT Industries Inc debe garantizar el sistema de control de emisi n evaporativa en la equipo peque o para uso fuera de carreteras durante el per odo indicado abajo siempre y cuando dicho equipo no haya sido sujetos a abuso descuido o mantenimiento indebido El sistema de control de emisi n evaporativa puede incluir piezas como carburadores tanques de combustible mangueras de combustible tapas de combustible v lvulas recipientes filtros mangueras de vapor abrazaderas conectores y otros componentes asociados COBERTURA DE LA GARANT A DEL FABRICANTE Este sistema de control de emisi n evaporativa est garantizado por dos a os En caso de existir una pieza defectuosa relacionada con la emisi n evaporativa sta ser reparada o reemplazada por OWT Industries Inc RESPONSABILIDADES DEL PROPIETARIO EN RELACI N CON LA GARANTIA H Como propietario de equipo peque o para uso fuera de carreteras usted es responsable de la realizaci n del mantenimiento necesario indicado en el manual del propietario OWT Industries Inc le recomienda guardar todos los recibos y facturas de mantenimiento de la equipo peque o para uso fuera de carreteras no obstante OWT Industries Inc no puede negar la cobertura de la garant a nicamente por la carencia de recibos E Sin
110. un lugar bien ventilado y con el tanque de combustible vac o El combustible no se debe guardar cerca del generador Antes de transportar la unidad en un veh culo vac e el tanque de combustible cierre la v lvula del combustible e inmovilice aqu lla Deje enfriar elmotor durante cinco minutos antes de reabastecerlo de gasolina Para reducir el riesgo de incendio o de lesiones por quemadura maneje con cuidado el combustible Es sumamente inflamable No fume mientras est mezclando el combustible o reabasteciendo el tanque Almacene el combustible en un recipiente aprobado para gasolina Coloque la unidad sobre el piso nivelado apague el motor y deje que se enfr e antes de reabastecerlo de combustible Afloje la tapa del tanque de combustible para aliviar la presi n y para evitar que se escape combustible por la tapa Despu s de reabastecer de combustible la unidad ponga la tapa y apri tela firmemente Limpie todo el combustible que se haya derramado de la unidad Nunca intente en ninguna circunstancia eliminar el combustible derramado quem ndolo Los generadores vibran durante el uso normal Durante y despu s del uso del generador inspeccione el generador as como los cordones de extensi n y los cordones de corriente conectados a ste para ver si tienen da os causados por la vibraci n Deben repararse o reemplazarse los art culos da ados seg n sea necesario No use enchufes ni cordones que muestren s
111. underneath to support WN Locate the following items 2 Support Feet 4 Lock Nuts 1 4 20 4 Bolts 1 4 20 x 1 5 in E Insert bolts through the foot and frame as shown E Install lock nuts and tighten securely NW Repeat with remaining foot Page 11 English ASSEMBLY INSTALLING THE WHEELS ATTACHING THE HANDLE ASSEMBLY See Figure 4 See Figure 6 Wheels are provided to assist in moving the generator to the NH Locate the following items desired location and should be installed on the same side Handle as the recoil starter 1 Bolt 1 4 20 x 1 5 in 1 Lock Nut 1 4 20 E Place the handle on the handle bracket E Slide the bolt 1 4 20 x 1 5 mm through the handle and 2 Spacers handle bracket install lock nut and tighten securely 2 Lock Nuts 3 8 m Raise the end of the generator on the side opposite the WARNING recoil starter to gain access to the frame bottom securely position props underneath to support NW Locate the following items 2 Wheels 2 Bolts 3 8 16 x 4 25 in Do not attempt to lift the unit by the handle assembly If it is necessary to lift the generator always grasp by the frame Use proper lifting techniques to avoid back injury E Insert a wheel spacer into the center of the wheel NW Slide bolt through the wheel spacer then through the wheel mounting hole on the frame E Install nut on bolt and tighten securely WN Repeat the process on the other side to install second wheel INS
112. urn it freight prepaid or take it in to a manufacturer authorized service center for BLACKMAX generators You may obtain the location of the authorized service center nearest you by calling toll free 1 800 726 5760 or by logging on to the BLACKMAX website at www blackmaxtools com When requesting warranty service you must present the original dated sales receipt The authorized service center will repair any faulty workmanship and either repair or replace any part covered under the warranty at our option at no charge to you ADDITIONAL LIMITATIONS To the extent permitted by applicable law all implied warranties including warranties of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE are disclaimed Any implied warranties including warranties of merchantability or fitness for a particular purpose that cannot be disclaimed under state law are limited to three years from the date of purchase OWT Industries Inc is not responsible for direct indirect incidental or consequential damages Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty applies to product sold in the U S A Canada and Mexico only Please consult BLACKMAX s website www b

Download Pdf Manuals