Installation Instructions Electric Dryer 10

image

Contents

1. 4 LEVELING LEGS 6 ALCOVE OR CLOSET INSTALLATION elf your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back eThe dryer MUST be vented to the outdoors See the EXHAUST INFORMATION sections 3 amp 4 e Minimum clearance between dryer cabinet and adjacent walls or other surfaces is O in either side 3 in front 3 in rear e Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in eCloset doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed NOTE WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER MINIMUM CLEARANCE FROM THE WALLIS 5 5 in Installation Instructions 7 BATHROOM OR BEDROOM INSTALLATION e The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 3 amp 4 e The installation must conform with local codes or in the absence of local codes with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 8 MOBILE OR MANUFACTURED HOME INSTALLATION e Installation must conform to the MANUFACTURED HOME CONSTRUCTION amp SAFETY STANDARD TITLE 24 PART 32 80 or when such standard is not applicable with AMERICAN NATIONAL STANDARD FOR MOBILE HOME ANSI NFPA NO 5018 eThe dryer MUST be vented to t
2. e Save these instructions Installers Be sure to leave these instructions with the customer e Note to Customer Keep these instructions with your Owner s Manual for future reference e Before the old dryer is removed from service or discarded remove the dryer door e Service information and the wiring diagram are located in the control console e Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children e Install the dryer where the temperature is above 50 F for satisfactory operation of the dryer control system e Product failure due to improper installation is not covered under the Warranty TOOLS YOU WILL NEED en SLIP JOINT PLIERS NOTE Installation and service of this dryer requires basic mechanical and electrical skills It is your responsibility to contact a qualified installer to make the electrical connections MATERIALS YOU WILL NEED 7 VAR RECOMMENDED 4 DIA METAL 4 DUC EXHAUST SAFETY DDD rt fho ans 4 DIA FLEXIBLE METAL SEMI RIGIO UL LISTED TRANSITION DUCT IF NEEDED LUDES 2 ELBOWS DRYER POWER CORD KIT NOT PROVIDED 4 SPRING WITH DRYER CLAMPS 2 UL RATED 1032 E WITH 3 OR 4 PRONGS IDENTIFY THE PLUG DUCT TAPE GLOVES LEXIBLE METAL FOIL TYPE D TRANSITION DUCT i COVER PLATE IF NEEDED FLAT BLADE SCREWDRIVER HOUSE RECEPTACL ULRECOGNIZED BEFORE PURCHASING LINE CORD
3. RELIEF TYPE AS PER THE R IF NEEDED KIT WE1M454 Step 7 Level your dryer see section 5 Step 8 Check the operation of the power supply and venting Step 9 Place the Owner s Manual and the Installation Instructions in a location where they will be noticed by the owner Step 1 Prepare the area and exhaust for installation of new dryer see section 1 Step 2 Check and ensure the existing external exhaust is clean see section 1 and meets attached installation specifications see section 3 ep 3 Remove the foam shipping pads see section 1 ep 4 Move the dryer to the desired location ep 5 Connect the power supply see section 2 ep 6 Connect the external exhaust see section 4 For alcove or closet installation see section 6 For bathroom or bedroom installation see section 7 For mobile or manufactured home see section 8 For garage installation if allowed by local codes see section 9 For For side or bottom exhaust see section 10 234D1052P005 31 16629 2 03 12 GE nun wn Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are 0 in clearance both sides 1 in front and 3 in rear Consideration must be given to provide adequate clearance for installation and service PREPARING FOR INSTALLATION OF NEW DRYER TIP Install your dryer before installing your washer This will allow be
4. 561 3344 Canada
5. all terminal block screws 3 securely Properly secure power cord to strain relief Reinstall the cover AWARNING never LEAVE THE COVER OFF OF THE TERMINAL BLOCK EXHAUST INFORMATION AAWARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 in 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EX HAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short run installations Elbows Metal Metal 0 90 Feet 1 60 Feet 2 45 Feet 3 35 Feet 4 25 Feet 60 Feet 45 Feet 35 Feet 25 Feet 15 Feet EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife Termination should present minima
6. instrucciones con el Manual del propietario Si se instala un conducto flexible de metal semi r gido o de tipo papel de para referencia futura aluminio debe estar aprobado por UL e instalarse de acuerdo con las e Antes de que la secadora antigua sea retirada instrucciones de C mo conectar la secadora a la ventilaci n dom stica del servicio o eliminada qu tele la puerta de las p ginas 4 5 de este manual Los materiales de ventilaci n e La informaci n sobre reparaciones y el flexibles a menudo se desploman se aplastan y atrapan pelusas Estas diagrama del cableado se encuentran en la condiciones obstruyen la corriente de aire de la secadora e incrementan consola de control el riesgo de incendio e No permita que ni os se suban o se metan e No instale o almacene este aparato en un lugar donde se vea expuesto dentro del aparato Se requiere una super al agua y o a las inclemencias del tiempo visi n estricta cuando el aparato es utilizado e Guarde estas instrucciones Instaladores Aseg rese de dejar estas cerca de ni os instrucciones al consumidor Instale la secadora en lugares donde la temperatura sea mayor a 50 F para un _ f funcionamiento satisfactorio del sistema de NOTA La instalaci n y reparaci n de esta secadora requieren capaci control de la secadora dades mec nicas y el ctricas b sicas Es su responsabilidad contactar e La garant a no cubre las fallas del producto a un instalador calificado par
7. shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base Installation Instructions ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET e Preassemble 4 elbow with 4 duct Wrap duct tape around joint e Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct ACAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct EXHAUST CAN LEFT OR RIGHT SIDE e Apply duct tape as shown on the joint between the dryer internal duct and the elbow Bu CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET e Insert the elbow through the rear opening and connect it to the dryer internal duct e Apply duct tape on the joint between the dryer internal duct and elbow as shown above MW Wo SU CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET SIDES AND BOTTOM EXHAUST PLATE KIT WE1M454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location AAWARNING NEVER LEAVE THE BA
8. CK OPENING WITHOUT THE PLATE Kit WE1M454 REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY IMPORTANT PRODUCT NOTIFICATIONS Please go to www GEAppliances com or mail in your product registration card For questions on installation call 800 626 2000 US or 800 561 3344 Canadal Instrucciones Secadora El ctrica de instalaci n 10 Preguntas sobre la instalaci n Llame al 1 800 GECARES EE UU o visite nuestro sitio Web en www GEAppliances com EE UU ANTES DE COMENZAR AADVERTENCIA RIESGO DE INCENDIO Lea estas instrucciones por completo y con ll a detenimiento e Para reducir el riesgo de una lesi n grave o de muerte cumpla con todas las instrucciones de instalaci n IMPORTANTE Guarde estas instruc e La instalaci n de la secadora debe efectuarla un instalador calificado ciones para el uso de inspectores locales e Instale la secadora de ropa de acuerdo con estas instrucciones y en a cumplimiento de los c digos locales IMPORTANTE Siga todos los c digos cla secadora debe ms una salida al exterior y ordenanzas vigentes s e Utilice s lo un conducto r gido de metal de un di metro de 4 dentro del Nota al instalador Aseg rese de dejar gabinete de la secadora y use s lo un conducto de transici n aprobado estas instrucciones con el consumidor por UL entre la secadora y el conducto dom stico e Nota al consumidor Mantenga estas e NO instale una secadora de ropa con conductos de pl stico flexibles
9. Do not obstruct incoming or exhausted air CONNECTING THE DRYER TO HOUSE VENT e Provide an access for inspection and cleaning of the RIGID METAL TRANSITION DUCT exhaust system especially at turns and joints Exhaust e For best drying performance a rigid metal transition system shall be inspected and cleaned at least once a duct is recommended year e Rigid metal transition ducts reduce the risk of crushing There are multiple installation options celal 2 UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT Select the most appropriate method for If rigid metal duct cannot be used then UL listed flexible your installation situation metal semi rigid ducting can be used Kit WX08X10077 e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m Installation Instructions e For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying performance e Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT e In special installations it may be necessary to connect the dryer to the house vent using a flexible m
10. HO O IZQUIERDO AISLANTE e Aplique cinta aislante como puede verse en la junta entre el conducto interno de la secadora y el codo CINTA APRECAUCI N Las juntas del conducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad C MO AGREGAR UN CODO DE SALIDA A TRAVES DE LA PARTE INFERIOR DEL GABINETE e Introduzca el codo a trav s de la abertura trasera y con ctelo al conducto interno de la secadora e Aplique cinta aislante en la junta entre el conducto in terno de la secadora y el codo como puede verse abajo h Wo Um SKUD PRECAUCI N Las juntas del conducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad C MO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE SALIDAS POR LOS LADOS Y LA PARTE INFERIOR PLACA KIT WE1M454 Conecte los codos y conductos de metal est ndar para completar el sistema de salida Cubra la abertura trasera con la placa Kit WE1M454 disponible en su proveedor de servicios local Coloque la secadora en su ubicaci n final ADVERTENCIA NUNCA DEJE LA ABERTURA TRASERA SIN LA PLACA EN SU LUGAR Kit WEIM454 REGISTRE SU NUEVO APARATO PARA RECIBIR LAS NOTIFICACIONES DE PRODUCTOS IMPORTANTES Por favor vaya a www GEAppliances com o enviar por correo su tarjeta de inscripci n Para preguntas sobre la instalaci n llame al 800 626 2000 EE UU o 800
11. Installation Instructions Electric Dryer 10 Questions on Installation Call 800 GE CARES US or visit our web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT save these instructions for local inspector s use eIMPORTANT Observe all governing codes and ordinances e Note to Installer Be sure to leave these instructions with the customer AWARNING risk oF FIRE e To reduce the risk of severe injury or death follow all installation instructions e Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and in accordance with local codes e This dryer must be exhausted to the outdoors e Use only rigid metal 4 diameter ductwork inside the dryer cabinet and use only UL approved transition ducting between the dryer and the home duct e DO NOT install a clothes dryer with flexible plastic ducting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on pages 4 5 of this manual Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire e Do not install or store this appliance in any location where it could be exposed to water and or weather
12. LES O PREFABRICADAS e La instalaci n debe cumplir con la NORMA SOBRE CONSTRUCCI N Y SEGURIDAD DE CASAS PREFABRICADAS T TULO 24 PARTE 32 80 o cuando dicha norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS M VILES ANSI NFPA N 5018 La secadora DEBE tener ventilaci n al exterior con la terminaci n bien sujeta a la estructura de la casa m vil Ver la INFORMACI N SOBRE SALIDA secciones 3 y 4 e La ventilaci n NO DEBE terminar debajo de una casa m vil o prefabricada El material del conducto de ventilaci n DEBE SER METAL No utilice tornillos para placas de metal u otros _ dispositivos de sujeci n que se extiendan al interior de la ventilaci n de salida e Ver la secci n 2 sobre informaci n sobre conexiones el ctricas 9 INSTALACI N EN GARAJE SI PERMITI DO POR LOS CODIGOS LOCALES eSecadoras instaladas en garages deben ser elevadas 18 pulgadas 46cm del nivel del piso LOISALIDA DE LA SECADORA HACIA LA DERECHA IZQUIERDA O PARTE INFE RIOR DEL GABINETE AADVERTENCIA ANTES DE EFECTUAR ESTA INSTALACI N DE SALIDA ASEG RESE DE DESCONECTAR LA SECADORA DEL SUMINISTRO EL CTRICO PROTEJA SUS MANOS Y BRAZOS DE LOS LADOS AFILADOS CUANDO TRABAJE DENTRO DEL GABINETE ASEG RESE DE USAR GUANTES QUITE EL TORNILLO EL RECORTE DESEADO S LO UNO Despegue y quite el recorte inferior derecho o izquierdo seg n corresponda Quite el tornillo ubicado dentro d
13. LY RECOMMEND SOLID WARNING TO REDUCE THE RISK METAL EXHAUST DUCTING HOWEVER IF OF FIRE OR PERSONAL INJURY ULLISTED METAL NOT PLASTIC e This clothes dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for the home exhaust duct eUse only 4 rigid metal or UL listed flexible metal STANDARD REAR EXHAUST semi rigid or foil type duct to connect the dryer to the Vented above floor level home exhaust duct It must be installed in accordance ELBOW HIGHLY with the instructions found in Connecting the Dryer to RECO House Vent on pages 4 5 of this manual Do not terminate exhaust in a chimney a wall a GANAN ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a potential fire hazard Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This ELBOW HIGHLY will cause lint to accumulate creating a potential fire RECOMMENDED LIV IRF hazard Do not assemble ductwork with any fasteners that NOTE ELBOWS WILL PREVENT DUCT extend into the duct These fasteners can accumulate KINKING AND COLLAPSING lint creating a potential fire hazard e
14. O DE LA CAMPANA DE SALIDA SE ABRA Y CIERRE LIBREMENTE NCLINE LA SECADORA DE COSTADO Y QUITE LAS ALMOHADILLAS DE ESPUMA PARA ENV O OM NDOLAS DE LOS COSTADOS Y ARRANC NDOLAS DE LAS PATAS DE LA SECADORA ASEG RESE DE QUITAR TODAS LAS PIEZAS DE ESPUMA UBICADAS ALREDEDOR DE LAS PATAS INFORMACION SOBRE CONEXIONES ELECTRICAS RIESGO DE INCENDIO DESCARGA ELECTRICA Y LESIONES PERSONALES a e NO UTILICE UN CABLE DE EXTENSION O UN ENCHUFE ADAPTADOR CON ESTE APARATO La secadora debe contar con una conexi n el ctrica a tierra en cumplimiento con los c digos y ordenanzas locales o si stos no existieran de acuerdo con el C DIGO EL CTRICO NACIONAL ANSI NFPA N 70 REQUISITOS EL CTRICOS Esta secadora debe conectarse a un circuito derivado individual con la protecci n de los fusibles de tiempo retardado o interruptores de circuito requeridos Se requiere un circuito de tres o cuatro cables fase nica 120 240V 120 208V 60Hz y 30 amperios INSTRUCCIONES DE CONEXI N A TIERRA Esta secadora debe conectarse a un sistema de cableado permanente con conexi n a tierra o debe utilizarse un con ductor de conexi n a tierra del equipamiento con los con ductores de circuito y conectarse a la terminal de conexi n a tierra del aparato COMO CONECTAR LA SECADORA USAN DO UNA CONEXION DE 4 CABLES DEBE UTILIZARSE EN INSTALACIONES DE CASAS MOVILES NOTA Desde el 1 de enero de 1996 el C digo El ctrico Nacio
15. R FRENTE A PARTE TRASERA LADO ALADO APATAS DE NIVELACI N 6 INSTALACI N EN NICHO O EN CLOSET e Su secadora puede instalarse en un nicho o closet como se indica en la etiqueta de la parte trasera del aparato e Esta secadora DEBE tener una ventilaci n al exterior Ver la INFORMACI N SOBRE SALIDA secciones 3 y 4 e El espacio libre m nimo entre el gabinete de la secadora y las paredes adyacentes u otras superficies es de 0 pulg sobre ambos lados 3 pulg en el frente 4 pulg en la parte trasera e El espacio vertical m nimo desde el piso a los gabinetes superiores cielorraso etc es de 52 pulg e Las puertas del closet deben contar con rejillas u otro tipo de ventilaci n y deben tener por lo menos 60 pulg cuadradas de espacio abierto igualmente distribuido Si el closet incluye una lavadora y una secadora las puertas deben contener un m nimo de 120 pulg cuadradas de espacio abierto distribuido uniformemente NOTA CUANDO EL CONDUCTO DE SALIDA EST UBICADO EN LA PARTE TRASERA DE LA SECADORA EL ESPACIO LIBRE MINIMO DESDE LA PARED DEBE SER 5 5 PULGADAS Instrucciones de instalaci n INSTALACI N EN BA OS O DORMITORIOS e Esta secadora DEBE tener una ventilaci n al exterior Ver la INFORMACI N SOBRE SALIDA secciones 3 y 4 e La instalaci n debe cumplir con c digos locales o si no existieran con el C DIGO EL CTRICO NACIONAL ANSI NFPA N 70 s INSTALACION EN CASAS MOVI
16. a realizar las conexiones el ctricas debido a una instalaci n incorrecta HERRAMIENTAS MATERIALES NECESARIOS NECESARIAS ZL E f e EI CONDUCTO DE METAL DE 4 DE DIA EA RECOMENDADO IN KITDECABLE ALICATES DE JUNTA DESLIZANTE ABRAZADERAS CODO DE METAL DE ENERGIA ON DE CONDUCTO DE 4 2 DEW DEDIA CAMPANA GAFAS DE LA SECADORA DESTORNILLADOR PLANO CONDUCTO DE TRANSICI N DE METAL ABRAZADERAS Z LA SECADORA FLEXIBLE SEMI R GIDO DE 4 DE DI j a APROBADO POR UL SI FUERA NECESARIO DE RESORTE DE 4 2 CAPACIDAD UL DE gt KIT WX08X10077 INCLUYE 2 CODOS Pinata ae DESTORNILLADOR DE ESTRELLA Vw A nu ANTES DE COMPRAR EL J GUANTES POR UL CORD N IDENTIFIQUE Ss 2 Y CINTA ADHESIVA EL TIPO DE ENCHUFE DE ACUERDO CON EL SS CONDUCTO DE TRANSICI N DE METAL Y EEG FLEXIBLE TIPO PAPEL DE ALUMINIO DE 4 DE DIA ur APROBADO POR UL SI FUERA NECESARIO A DE LA CASA Paso 1 Prepare el rea y la salida para la instalaci n de la nueva de la ventilaci n secadora ver secci n 1 Paso 9 Coloque el manual del propietario y las instrucciones de Paso 2 Verifique y aseg rese de que la salida al exterior existente instalaci n en un lugar de f cil acceso para el propietario est limpia ver secci n 1 y que cumpla con las especifi caciones de instalaci n incluidas ver secci n 3 Paso 3 Quite las almohadillas de espuma para env o ver secci n 1 Paso 4 Desplace la secado
17. adora de la caja el ctrica 2 Verifique que el cable de la secadora est desenchufado del tomacorriente 3 Quite la tapa del cable de energ a ubicada en la parte trasera inferior 4 Instale un alivio de tensi n de pulgadas reconocido por UL en el orificio de entrada del cable de energ a Pase el cable de energ a a trav s del alivio de tensi n 5 Conecte el cable de energ a de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N 6 Aseg rese de que la cinta de conexi n a tierra est conectada a la terminal neutral central del bloque y al tornillo verde de conexi n a tierra de la parte trasera del gabinete Ajuste por firmemente todos los tornillos 3 del bloque terminal 7 Ajuste bien el cable de energ a al alivio de tensi n 8 Vuelva a instalar la tapa AADVERTENCIA NUNCA OL VIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL INFORMACI N DE SALIDA AADVERTENCIA EN CANAD Y LOS ESTADOS UNIDOS EL DI METRO DE CONDUCTO DE SALIDA REQUERIDO ES DE 4 PULG 102 mm NO UTILICE UN CONDUCTO DE UNA LONGITUD MAYOR A LA ESPECIFICADA EN LA TABLA DE LONGITUD DE SALIDA Al utilizar una salida de mayor longitud a la especificada se e Incrementar n los tiempos de secado y el costo de energ a e Reducir la vida til de la secadora e Acumular pelusa lo qu
18. e January 1 1996 the National Electric code requires that the new constructions utilize a 4 wire connection to an electric dryer er NT WIRE RELOCATE GREEN GROUND SCREW RE GREEN OR YELLOW WIRE STRAIN RELIEF BRACKET REMOVE GROUND STRAP AND DISCARD KEEP GREEN NEUTRAL White 3 4 UL HOT RECOGNIZED WIRE STRAIN RELIEF 4 10 AWG MINIMUM COPPER CONDUCTORS OR 120 240V 30A POWER SUPPLY CORD KIT MARKED FOR USE WITH DRYERS amp PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS NOT SUPPLIED 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw for step 7 5 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N 7 Attach ground wire of power cord with the green ground screw hole above strain relief bracket Tighten all terminal block screws 3 securely 8 Properly secure power cord to strain relief 9 Reinstall the cover AWARNING never LEAVE THE COVER OFF OF THE TERMINAL BLOCK Installati
19. e podr a generar un riesgo potencial de incendio La correcta instalaci n de salida es SU RESPONSABILIDAD Los problemas generados por una instalaci n incorrecta no se encuentran cubiertos por la garant a Quite y descarte el conducto de transici n existente de pl stico o de papel de aluminio y coloque un conducto de transici n aprobado por UL La longitud MAXIMA PERMITIDA del conducto y la cantidad de codos del sistema de salida dependen del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas a continuaci n La longitud m xima del conducto para conductos r gidos de metal se indica en la siguiente tabla LONGITUD DE SALIDA LONGITUD M XIMA RECOMENDADA Tipos de campana de salida Utilizar s lo en instalaciones Recomendado de trayecto corto 90 Pies 60 Pies 1 60 Pies 45 Pies 2 45 Pies 35 Pies 3 35 Pies 25 Pies LISTA DE CONTROL DEL SISTEMA DE SALIDA CAMPANA O CUBIERTA DE PARED nstale la salida de modo de evitar contracorrientes o el ingreso de p jaros u otros insectos o animales La boca de salida debe presentar una resistencia m nima al flujo de salida y debe requerir poco o ning n mantenimiento para evitar las obstrucciones unca instale un filtro dentro o sobre el conducto de salida Esto podr a provocar una acumulaci n de pelusa Las cubiertas de pared deben instalarse por lo menos a 12 sobre el nivel del suelo o cualquier otra
20. el conducto de salida de la secadora y cons rvelo Saque el conducto de la secadora UBICACI N DE LA LENG ETA ORIFICIO DE MONTAJE 13 1 2 13 1 4 para ventilaci n inferior Corte el conducto como puede verse y conserve la porci n A GIRE LA LENG ETA HASTA 45 A trav s de la abertura trasera ubique la leng eta en el medio de la base del aparato Levante la leng eta hasta alrededor de 45 utilizando un destornillador de lados planos C MO AGREGAR CONDUCTOS NUEVOS ORIFICIO DE MONTAJE PORCI N A SALIDA LATERAL POR DERECHA O IZQUIERDA Vuelva a conectar la porci n cortada A del conducto a la carcasa del ventilador Aseg rese de que el conducto m s corto se encuentre alineado con la leng eta de la base Utilice el tornillo conservado con anterioridad para sujetar el conducto en su lugar a trav s de la leng eta de la base del artefacto Instrucciones de instalaci n C MO AGREGAR CODOS Y CONDUCTOS DE SALIDA HACIA LA IZQUIERDA O DERE CHA DEL GABINETE e Arme previamente un codo de 4 con un conducto de 4 Coloque cinta aislante alrededor de la junta Introduzca el montaje del conducto el codo primero a trav s de la abertura lateral y conecte el codo al conducto interno de la secadora A PRECAUCI N Aseg rese de no tirar o da ar los cables el ctricos ubicados dentro de la secadora cuando introduzca el conducto LA SALIDA PUEDE AGREGARSE A LOS LADOS DEREC
21. etal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct e In Canada and the United States only the flexible metal foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e Avoid resting the duct on sharp objects ELBOW HIGHLY RECOMMENDED DO NOT SIT DRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp LEVELING AND STABILIZING YOUR DRYER Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear LEVEL LEVEL FRONT TO BACK SIDE TO SIDE
22. he outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 3 amp 4 eThe vent MUST NOT be terminated beneath a mobile or manufactured home e The vent duct material MUST BE METAL e Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent e See section 2 for electrical connection information 9 GARAGE INSTALLATION IF ALLOWED BY LOCAL CODES e Dryers installed in garages must be elevated 18 inches 46cm above the floor DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET AWARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES REMOVE SCREW REMOVE DESIRED KNOCKOUT ONE ONLY Detach and remove the bottom right or left side knockout as desired Remove the screw inside the dryer exhaust duct and save Pull the duct out of the dryer FIXING HOLE Cut the duct as shown and keep portion A TAB LOCATION BEND TAB Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver ADDING NEW DUCT FIXING HOLE PORTION A RIGHT OR LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower housing Make sure that the
23. l resistance to the exhaust air flow and should require little or no maintenance to prevent clogging Never install a screen in or over the exhaust duct This could cause lint build up Wall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90 One turn of 45 or less may be ignored Two 45 turns should be treated as one 90 turn Each turn over 45 should be treated as one 90 turn Installation Instructions SEALING OF JOINTS STANDARD REAR EXHAUST All joints should be tight to avoid leaks The male end of Vented at floor level each section of duct must point away from the dryer The duct shall not be assembled with screws or other For straight line installation connect fastening means that extend into the duct and catch lint u Duct joints can be made air and moisture tight by clamp wrapping the overlapped joints with duct tape en Horizontal runs should slope down toward the outdoors 1 4 inch per foot INSULATION E Duct work that runs through an unheated area or is y lt gt near air conditioning should be insulated to reduce DUCT TAPE OR pp condensation and lint build up DUCTELAMP Z X i 4 METAL DUCT CUT TO PROPER LENGTH EXHAUST CONNECTION DUCT CLAMP A NOTE WE STRONG
24. les tipo papel de aluminio que cumplan con el Resumen para conductos de transici n para secadoras de ropa Tema 21584 e Nunca instale conductos de metal flexibles en paredes cielorrasos pisos u otros espacios cerrados e La longitud total del conducto de metal flexible no deber superar los 8 pies 2 4 m e No coloque el conducto sobre objetos afilados RECOMIENDA ENFATICAMENTE RECOMIENDA So ENF TICAMENTE IS HACER r NAM IA NO COLOQUE LA SECADORA SOBREUNA SALIDA FLEXIBLE NO UTILICE UNA LONGITUD DE SALIDA EXCESIVA NO APLASTE LA SALIDA FLEXIBLE CONTRA LA PARED Para un mejor desempe o de secado 1 Deslice un extremo del conducto sobre la tuber a de salida de la secadora de ropa 2 Fije el conducto con una abrazadera 3 Con la secadora en su posici n permanente extienda el conducto en su longitud total Deje que se superpongan 2 de conducto con la tuber a de salida Corte y quite el tramo de conducto que sobre Mantenga el conducto lo m s recto posible para lograr una corriente de aire m xima a Fije el conducto a la tuber a de salida con la otra abraza era 5ICOMO NIVELAR Y ESTABILIZAR SU SECADORA Coloque la secadora en posici n vertical cerca de la ubicaci n definitiva y ajuste las cuatro patas de nivelaci n en los extremos para garantizar que la secadora se encuentre nivelada de lado a lado y del frente a la parte trasera NIVELAR NIVELA
25. lida especialmente en las curvas y juntas El sistema de salida debe inspeccionarse y limpiarse por lo menos una vez al a o Existen opciones m ltiples de instalaci n Seleccione el m todo m s apropiado para su instalaci n SALIDA TRASERA ESTANDAR Ventilaci n a nivel del suelo Para una instalaci n en l nea recta conecte la salida de la secadora a la campana de salida al exterior con cinta aislante o una abrazadera ABERTURA DE CONDUCTO EXTERIOR ty CINTA AISLANTE O ABRAZADERA DE CONDUCTO CONDUCTO DE METAL DE 4 CORTADO CON LA LONGITUD ADECUADA CINTA AISLANTE O ABRAZADERA DE CONDUCTO NOTA RECOMENDAMOS ENF TICAMENTE EL USO DE CONDUCTOS DE SALIDA DE METAL S LIDO SIN EMBARGO SI SE USAN CONDUCTOS FLEXIBLES ESTOS DEBEN SER DE METAL APROBADOS POR UL NO DE PL STICO SALIDA TRASERA EST NDAR Ventilaci n sobre el nivel del suelo SE RECOMIENDA EL USO DE CODOS h h i 1 CONFIGURACI N RECOMENDADA PARA MINIMIZAR LAS OBSTRUCCIONES DE LA SAL SE RECOMIENDA EL USO DE CODOS N Y NOTA LOS CODOS EVITAN QUE LOS CONDUCTOS SE DOBLEN O CAIGAN COMO CONECTAR LA SECADORA A LA VEN TILACION DOMESTICA CONDUCTO DE TRANSICION DE METAL RIGIDO e Para un mejor desempe o de secado se recomienda un conducto de transici n de metal rigido e Los conductos de transici n de metal r gidos reducen el riesgo de aplastamientos y t
26. nal exige que las nuevas construcciones utilicen una conexi n de 4 cables a una secadora el ctrica QUITE LA CINTA DE CONEXI N A TIERRA Y DESC RTELA CONSERVE EL TORNILLO VERDE Er N DE CONEXI N A Ir VIVO VUELVA A COLOCAR EL TORNILLO VERDE DE CONEXI N A TIERRA AQU CABLE VERDE SOPORTE DE ALIVIO N fi S n NEUTRAL blanco ALIVIO DE TENSI N CABLE ne 4 NES VIVO 4 CONDUCTORES DE COBRE 10 AWG M NIMO O KIT DE CABLE DE SUMINISTRO DE ENERG A DE 120 240V 30A MARCADO PARA USO EN SECADORAS Y PROVISTO CON TERMINALES DE BUCLE CERRADO O DE PALA CON EXTREMOS HACIA ARRIBA NO PROVISTOS 1 Desactive el interruptor de circuitos 30 amperios o quite el fusible del circuito de la secadora de la caja el ctrica 2 Verifique que el cable de la secadora est desenchufado del tomacorriente 3 Quite la tapa del cable de energ a ubicada en la parte trasera inferior 4 Quite y descarte la cinta de conexi n a tierra Conserve el tornillo verde de conexi n a tierra para el paso 7 5 Instale un alivio de tensi n de pulgadas reconocido por UL en el orificio de entrada del cable de energ a Pase el cable de energ a a trav s del alivio de tensi n 6 Conecte el cable de energ a de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N 7 Conecte el cable a tier
27. obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con por lo menos 4 pies de conducto recto incluyendo la distancia entre la ltima curva y la campana de salida GIROS QUE NO SON DE 90 e Un giro de 45 o menos puede ignorarse e Dos giros de 45 deben tratarse como un giro de 90 e Todos los giros de m s de 45 deben tratarse como un giro de 90 Instrucciones de instalaci n SELLADO DE JUNTAS e Todas las juntas deben estar bien selladas para evitar p rdidas El extremo macho de cada secci n de conducto debe apuntar en direcci n opuesta a la secadora e El conducto no deber instalarse con tornillos u otros medios de sujeci n que se extiendan dentro del conducto y enganchen pelusas e Las juntas de los conductos deben ser herm ticas al aire y a la humedad mediante la superposici n de juntas con cinta aislante e Los tramos horizontales deben tener una inclinaci n hacia el exterior de 1 4 por pie AISLACION Los conductos instalados a trav s de una rea sin calefacci n o ubicados cerca de un acondicionador de aire deben aislarse para reducir la condensaci n y la acumulaci n de pelusas CONEXI N A LA SALIDA ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO O DE LESIONES PERSONALES eEsta secadora de ropa debe tener una salida al exterior e Utilice s lo un conducto de metal r gido de 4 para el conduc
28. on Instructions CONNECTING DRYER USING 3 WIRE CONNECTION IF REQUIRED BY LOCAL CODE INSTALL EXTERNAL GROUND NOT PROVIDED TO GROUNDED METAL COLD WATERPIPEOR GREEN OTHER ESTABLISHED GROUND DETERMINED BY A QUALIFIED ELECTRICIAN GROUND GROUND STRAP SCREW HOT WIRE STRAIN RELIEF BRACKET 3 4 UL RECOGNIZED NEUTRAL OT White WIRE 3 10 AWG MINIMUM COPPER CONDUCTORS OR 120 240V 30A POWER SUPPLY CORD KIT MARKED FOR USE WITH DRYERS amp PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS NOT SUPPLIED 3 wire Connection Not for use in Canada DO NOT use for Mobile Home Installations NOT for use on new construction NOT for use on recreational vehicles NOT for use in areas where local codes prohibit grounding through the neutral conduction Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box Be sure the dryer cord is unplugged from the wall Remove the power cord cover located at the lower back Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief Connect power cord as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N Be sure ground strap is connected to neutral center terminal of block and to green ground screw on cabinet rear Tighten
29. orceduras CONDUCTO DE TRANSICI N DE METAL FLEXIBLE SEMI RIGIDO APROBADO POR UL e Sino puede utilizarse un conducto de metal r gido entonc es puede usarse un conducto de metal flexible semi rigido aprobado por UL Kit WX08X10077 e Nunca instale conductos de metal flexibles en paredes cielorrasos pisos u otros espacios cerrados e La longitud total del conducto de metal flexible no deber superar los 8 pies 2 4 m 6 Instrucciones de instalaci n e Para muchas aplicaciones se recomienda enf ticamente la instalaci n de codos en la secadora y en la pared ver ilustraciones de abajo Los codos permiten que la secadora se ubique cerca de la pared sin torcer o aplastar el conducto de transici n lo que potencia al m ximo el desempe o de secado e No coloque el conducto sobre objetos afilados CONDUCTO DE TRANSICI N DE METAL FLEXIBLE SEMI RIGIDO APROBADO POR UL e En instalaciones especiales puede ser necesario conectar la secadora a la ventilaci n dom stica utilizando un conducto de metal flexible tipo papel de aluminio Puede utilizarse un conducto de metal flexible tipo papel de aluminio aprobado por UL S LO en instalaciones en las que no pueden usarse conductos de metal r gidos o flexibles semi r gidos Y en las que puede mantenerse un di metro de 4 a lo largo de todo el conducto de transici n En Canad y los Estados Unidos solamente deber n utilizarse los conductos de metal flexib
30. ra a la ubicaci n deseada Paso 5 Conecte el suministro de energ a ver secci n 2 Paso 6 Conecte la salida al exterior ver secci n 4 Paso 7 Nivele su secadora ver secci n 5 Paso8 Verifique el funcionamiento del suministro de energ a y Para instalaci n en nicho o closet ver secci n 6 Para instalaci n en ba os o dormitorios ver secci n 7 Para casas m viles o prefabricadas ver secci n 8 Para instalaci n en garaje si permitido por los codigos locales ver secci n 9 Para salidas laterales o por la parte inferior ver secci n 10 234D01052P005 31 16629 2 03 12 GE Instrucciones de instalaci n Espacio m nimo diferente a instalaci n en nichos o closets Los espacios libres m nimos respecto de superficies combustibles y de aberturas de aire son Espacio de O pulg a ambos lados 1 pulg en el frente y 3 pulg en la parte trasera Debe tenerse en cuenta un espacio libre adecuado para un funcionamiento y reparaci n correctos PREPARACION PARA LA INSTALACION DE UNA SECADORA NUEVA CONSEJO Instale su secadora antes de instalar la lava dora Esto permitir un mejor acceso cuando instale la salida de la secadora C MO QUITAR PELUSA DE LA ABERTURA DE LA SALIDA DE LA PARED e Quite y descarte el conducto de transici n existente de pl stico o de papel de aluminio y coloque un conducto de transici n aprobado por UL ABERTURA DE CONDUCTO INTERNA VERIFIQUE QUE Ts EL REGULADOR DE TIR
31. ra del cable de energ a con el tornillo verde de conexi n a tierra orificio sobre el soporte de alivio de tensi n Ajuste por firmemente todos los tornillos 3 del bloque terminal 8 Ajuste bien el cable de energ a al alivio de tensi n 9 Vuelva a instalar la tapa AADVERTENCIA nunca oL VIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL Instrucciones de instalaci n C MO CONECTAR LA SECADORA UTILI ZANDO UNA CONEXION DE 3 CABLES SI AS LO REQUIRIERAN LOS C DIGOS TORNILLO A LOCALES INSTALE UNA CONEXI N VERDE nn CONEXION A TIERRA EXTERNA NO PROVISTA DE CONEXI N A METAL CON CONEXI N A TIERRA ATIERRA TUBER AS DE AGUA FR A CON CONEXI N SOPORTE A TIERRA U OTRA CONEXI N A TIERRA QR DE ALIVIO N DE TENSI N ESTABLECIDA POR UN ELECTRICISTA CALIFICADO gt ALIVIO DE TENSI N DE RECONOCIDO ane CABLE VIVO 3 CONDUCTORES DE COBRE 10 AWG M NIMO O KIT DE CABLE DE SUMINISTRO DE ENERG A DE 120 240V 30A MARCADO PARA USO EN SECADORAS Y PROVISTO CON TERMINALES DE BUCLE CERRADO O DE PALA CON EXTREMOS HACIA ARRIBA NO PROVISTOS Conexi n de 3 cables NO usar en Canad NO usar en instalaciones en casas m viles NO usar en casas nuevas NO usar en veh culos recreativos NO usar en reas donde los c digos locales proh ben la connexi n el ctrica a tierra por el medio del cable neutral 1 Desactive el interruptor de circuitos 30 amperios o quite el fusible del circuito de la sec
32. to de salida dom stico eUse s lo un conducto de metal r gido de 4 o de metal flexible semi r gido o de tipo papel de aluminio aprobado por UL para conectar la secadora al conducto de salida dom stico Debe instalarse de acuerdo con las instrucciones incluidas en C mo conectar la secadora a la ventilaci n dom stica de las p ginas 4 5 de este manual e No instale la boca de salida dentro de una chimenea pared cielorraso ventilaci n de gas espacio entre pisos tico bajo un piso con cerramiento o en cualquier otro espacio oculto de un edificio La acumulaci n de pelusas podr a provocar un riesgo potencial de incendio e Nunca instale la boca de salida dentro de un conducto com n con el sistema de salida de la cocina La combinaci n de grasa y pelusas podr a provocar un riesgo potencial de incendio e No utilice un conducto de una longitud mayor a la especificada en la tabla de longitud de salida Los conductos m s largos acumulan pelusa lo que genera un riesgo potencial de incendio e Nunca instale un filtro dentro o sobre el conducto de salida Esto provocar la acumulaci n de pelusas lo que genera un riesgo potencial de incendio No arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas sujeciones pueden acumular pelusa lo que genera un riesgo potencial de incendio e No obstruya el aire que entra y sale e Incluya un acceso para inspecci n y limpieza del sistema de sa
33. tter access when installing dryer exhaust REMOVING LINT FROM WALL EXHAUST OPENING e Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct INTERNAL DUCT OPENING CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS ELECTRICAL CONNECTION INFORMATION AAWARNING To REDUCE THE RISK OF FIRE ELECTRICAL SHOCK AND PERSONAL INJURY e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required GROUNDING INSTRUCTIONS This dryer must be connected to a grounded metal perma nent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal on the appliance CONNECTING DRYER USING 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION NOTE Sinc