1.                                  Wire   AWG Maximum Length Note  The following figures show wiring   22 600 ft  180 m  schematics for heat pump and straight cool   20 900 ft  270 m  units with electric heat  respectively    18 1500 ft  450 m    16 2000 ft  610 m   Wiring Schematic for  Motion Sensor              Remote Heat Pump  soon o      Front Desk Control  R n O   Y  uU U U U U U w  FD2 FD1 DR2 DR1 MS2 MS1   o O  LE   GH wi    Molex Housing Spec 396 06V  GL   gt      GONNECTIONS S     REMOTE WALL THERMOSTAT CONNECTIONS  When the wires are connected  the unit will be controlled Wiring Schematic for  by a remote wall thermostat  Straight Cool Unit   The thermostat connections supply the 24 Volt AC  When z       you install the digital electronic thermostat  you must set it m  to 24 Volt AC  See the installation Instruction in this manual y  for the Remote Wall Thermostat  w   o                               GH                24 Volt N  24 Volt L       GL             Compressor       Heater  Reversing Valve      High Fan             Low Fan                                         C a IICA       GLGHO W Y R C     Molex Housing Spec 396 07V     18 Room Air Conditioner          CONTROL BOARD  CONNECTIONS       ee    THERMOSTAT  CONNECTIONS            REMOTE LOCAL CONTROL    Control Locations    When remote local switch  1 is on  it allow the unit to operate by the control of Remote Wall Thermostat     The unit control by knobs are not available     e ENERGY SAVER    The energy
2.      E Voltage    Compressor will y Thermostat  not run  but fan  motor runs     Capacitor  Discharge  capacitor before servicing      E Compressor    E Overload    e Check voltage  See the limits on the preceding  page   If not within limits  call an electrician     e Check the wire connections  if loose  repair or    replace the terminal  If wires are off  refer to wiring  diagram for identification  and replace  Check wire  locations  If not per wiring diagram  correct     e Check for continuity  refer to the wiring diagram for  terminal identification  Replace the switch if circuit is  open     e Check the position of knob If not at the coldest  setting  advance the knob to this setting and restart  unit    Check continuity of the thermostat  Replace  thermostat if circuit is open     e Check the capacitor     Replace if not within  10  of manufacturer s rating   Replace if shorted  open  or damaged     l  Check the compressor for open circuit or ground  If i    open or grounded  replace the compressor       Check the compressor overload  if externally  mounted  Replace if open   If the compressor  temperature is high  remove the overload  cool it   and retest         24 Room Air Conditioner    Maintenance and Service             E Voltage e Check the voltage  See the limits on the preceding  page  If not within limits  call an electrician   E Overload e Check overload  if externally mounted   Replace if open   If the compressor temperature is  high  remove the overload  
3.      Uso       1  Estando expuesto a la circulaci  n directa de aire durante un extenso per  odo  de tiempo podr  a resultar peligroso para su salud  No exponga a las personas   animales dom  sticos  o a las plantas a la circulaci  n de aire durante largos  per  odos de tiempo    2  Debido a la probabilidad de falta de ox  geno  ventile el cuarto cuando est    utilizado el aparato junto con estufas u otros aparatos de calefacci  n    3  No utilice este aire acondicionado con prop  sitos especiales no especificados   Ej   conservaci  n de dispositivos de precisi  n  comida  animales dom  sticos   plantas y objetos de arte   Tal uso podr  a da  ar los art  culos        Limpieza y       1  No toque las piezas met  licas de la unidad al retirar el filtro  Manejar aristas  afiladas de metal puede causar lesiones    2  No utilice el agua para limpiar el interior del aire acondicionado  La exposici  n  al agua puede destruir el aislamiento  conduciendo a posibles descargas  el  ctricas    3  Al limpiar la unidad  aseg  rese antes de que la electricidad y el interruptor  est  n apagados  El ventilador rota a muy alta velocidad durante el  funcionamiento del equipo  Existe la posibilidad de lesiones si acciona  accidentalmente la electricidad de la unidad mientras limpia el interior de la  unidad     Para cuestiones de reparaci  n y mantenimiento  p  ngase en contacto con su  distribuidor de servicio autorizado     Manual del propietario 31    Introducci  n    Mi Introducci  n       A
4.    E Wire disconnected or e Connect wire  Refer to wiring diagram for terminal  connection loose identification  Repair or replace loose terminal   Capacitor  Discharge e Test capacitor   capacitor before testing   Replace if not within  10  of manufacturer s rating   Fan motor ARA o Replace if shorted  open  or damaged   will not run  E Will not rotate e Fan blade hitting shroud or cross flow fan hitting    scroll  Realign assembly     e Units using slinger ring condenser fans must have   4  to 5 16 inch clearance to the base  If it is hitting the  base  shim up the bottom of the fan motor with  mounting screw s      e Check fan motor bearings  if motor shaft will not  rotate  replace the motor        E Revolves on overload  e Check voltage  See limits on this page  If not within  limits  call an electrician   Fan motor runs   Test capacitor  R  intermittently Check bearings  Does the fan blade rotate freely     If not  replace fan motor     e Pay attention to any change from high speed to low  speed  If the speed does not change  replace the  motor        Owner s Manual 23    Maintenance and Service       E Grommets  E Fan    A E Loose set screw  Fan motor noise  0  E Worn bearings    e Check grommets  if worn or missing  replace them      If cracked  out of balance  or partially missing   replace it      Tighten it      If Knocking sounds continue when running or loose     replace the motor  If the motor hums or noise appears  to be internal while running  replace motor   
5.   APAGAR el aparato de aire acondicionado   pulse este bot  n de nuevo      Este bot  n tiene prioridad sobre cualquier otro               bot  n    MODE    Pulse este bot  n para desplazarse por los modos  COOL   FAN SHEA T  GOOL      AJUSTE DE LA TEMPERATURA    COOL   Pulse este bot  n para controlar    El ventilador funciona de forma continua para la autom  ticamente la temperatura de la sala   operaci  n de refrigeraci  n normal  Puede ajustar la temperatura entre 12  C y 30  C    ENERGY SAVER en incrementos de 1   C        El ventilador se detiene cuando el compresor deja de  Esteajuste aparece er laipantalla     enfriar  Cada 3 minutos aproximadamente  el  ventilador se encender   y la unidad comprobar   la  temperatura de la sala para determinar si es  necesario activar el aire fr  o       FAN    Funcionamiento del ventilador sin calefacci  n ni  refrigeraci  n       HEAT    El ventilador funciona de forma continua para la  operaci  n de calefacci  n normal         TIMER    SHUT OFF TIME     Normalmente  se utiliza por la noche mientras se duerme      Con la unidad en funcionamiento  utilice el temporizador para ajustar las horas durante las que  desea que est   en activada    e Para dormir con comodidad  y una vez que el temporizador est   ajustado  el ajuste de la  temperatura aumentar   en 1  C transcurridos 30 min   y en otros 1  C transcurridos otros 30 min    e Pulse el bot  n Timer para desplazarse por los ajustes 1 Hour   2 Hours         12 Hours maximum       
6.   ctrico  el trabajo  de reemplazamiento debe ser realizado   nicamente  por personal autorizado  utilizando las piezas de  cambio genuinas   nicamente       El trabajo de reemplazamiento debe ser realizado de  acuerdo con el C  digo El  ctrico Nacional   nicamente  por personal autorizado                                   Precauciones de Seguridad    E Precauciones de Seguridad    Para evitar lesiones al usuario o a otras personas y da  os a la propiedad  estas instrucciones est  n  seguirse     E Una operaci  n incorrecta por ignorar las instrucciones provocar   lesiones o da  os  La seriedad se clasifica  por las siguientes indicaciones          ADVERTENCIA Este s  mbolo indica la posibilidad de muerte o de seria lesi  n          PRECAUCION Este s  mbolo indica s  lo la posibilidad de lesiones o da  os a la propiedad             E Meanings of symbols used in this manual are as shown below     x    D No hacer         Siga estas instrucciones        ADVERTENCIA    E Instalaci  n                      No utilice un cable de Enchufe siempre a un No modifique ni alargue el  alimentaci  n  enchufe o una tomacorriente que tenga cable de alimentaci  n   toma suelta que est   da  ada  toma a tierra     e De lo contrario  podr  a provocar   De lo contrario  podr  a provocar   De lo contrario  puede provocar  un incendio o descarga un incendio o descarga una descarga el  ctrica o  el  ctrica  el  ctrica  incendio debido a la generaci  n   de calor        No desmonte ni modifique Tenga
7.   http   www lgservice com    LG PACKAGED TERMINAL    AIR CONDITIONER HEAT PUMP jg  OWNER S MANUAL    Please read the operating instructions and safety precautions carefully  and thoroughly before installing and operating your air conditioner     Please read through this manual  It contains valuable  information about your air conditioner  This manual  may help save time and money by explaining proper  air conditioner maintenance and preventing improper  use        Safety Precautions    Before Operation                              7  Introduction    8  Electrical Safety                                9  Installation oo    eee 11  Control Locations                           13  Maintenance and Service              21       2 Room Air Conditioner    Y FOR YOUR RECORDS    Write the model and serial numbers here    Model     Serial     You can find them on a label on the side of each unit   Dealer s Name   Date Purchased    E Staple your receipt to this page in the event you need it  to prove date of purchase or for warranty issues                 yo READ THIS MANUAL    Inside you will find many helpful hints on how to use and  maintain your air conditioner properly  Just a little  preventive care on your part can save you a great deal of  time and money over the life of your air conditioner    You ll find many answers to common problems in the chart  of troubleshooting tips  If you review our chart of  Troubleshooting Tips first  you may not need to call for  service at all    
8.  3  L  neas de 30A    So    Recept  culo de puesta a tierra  est  ndar de 265V clasificado a 20A     Utilice un fusible de   20 AMP  o un   nterruptor de 20 AMP    2500W Calentadora  gt    o un Interruptor de 15 AMP      Utilice un fusible de  30 AMP  o un  nterruptor de 30 AMP        Utilice un fusible de  tiempo de retardo de   20 AMP  o un disyuntor  de 20 AMP    2000W Calentadora  gt    o un Interruptor de 15 AMP         2    Recept  culo de puesta a tierra  est  ndar de 265V clasificado a 30A     AVISO       Utilice un fusible de  tiempo de retardo de  30 AMP  o un disyuntor  de 30 AMP        NO USE CABLE DE EXTENSI  N EN UNIDADES  DE 208  230  AND 208 230  265 VOLTIOS   Todo el cableado deber   realizarse de acuerdo    con los c  digos y reglamentos el  ctricos locales     El cableado dom  stico de aluminio podr  a  ocasionar problemas especiales  Consulte a un    electricista calificado           ADVERTENCIA    Seguraida Electrica    El cable de alimentaci  n puede incluir un  dispositivo interruptor de corriente  La  carcasa del enchufe cuenta con un bot  n de  prueba y otro de reinicio  El dispositivo debe  comprobarse peri  dicamente presionando  primero el bot  n TEST y despu  s RESET   Si el bot  n TEST no se desconecta o si el  bot  n RESET no permanece activo   suspenda el uso del aire acondicionado y  p  ngase en contacto con un t  cnico de  servicio cualificado        No presione nunca el bot  n de prueba durante el  funcionamiento  de lo contrario el enchufe 
9.  38 Aparato de aire acondicionado    Ubicaci  n de los controles    Autodiagno        FUNCION     Si la unidad sufriera una averia  el LED OPERATIVO verde situado en la pantalla PCB utilizado por la  unidad se iluminar   para indicar los errores     USO    Si el cliente ha registrado una queja en el Centro de servicio  deber   ser muy claro a la hora de registrar  dicha queja  y explicar con nitidez qu   est   ocurriendo  as   como consultar el manual del usuario a fin  de que  como cliente informado  pueda describir el problema    Esto tambi  n ayudar   a que el ingeniero pueda acudir en su ayuda con las herramientas necesarias  para su problema  Tambi  n ayudar   a mantener al cliente siempre al tanto de las necesidades y  caracter  sticas de la unidad    A continuaci  n encontrar   definidos algunos de los problemas que el LED indica parpadeando un cierto  n  mero de veces  indicando el error     Estos errores son los mencionados en la Tabla 13  como se muestra a continuaci  n                                            ENCENDIDO Normal  APAGADO Sin potencia   placa averiada  C  digos de aver  a  CH 01 Error del termistor de aire interior  CH 02 Error del termistor del serpent  n interior  CH 03 Error del termistor de aire exterior  s  lo PTHP   CH 04 Error del termistor del serpent  n exterior  s  lo PTHP   CH 05 Error de modo  CH 06 Error del punto de ajuste  CH 07 Cableado del termistor incorrecto          Manual del propietario 39    Ubicacion de los controles         E
10.  DESENCHUFE LA TOMA DE LA PARED        Limpieza del    El filtro del aire se debe revisar al menos dos veces al mes para comprobar si la limpieza es  necesaria  Las part  culas que queden atrapadas en el filtro se acumular  n y bloquear  n el  flujo del aire  Esto reduce la capacidad de refrigeraci  n y puede causar una acumulaci  n de    escarcha en las bobinas de enfriamiento     Si el filtro est   gastado o da  ado  c  mbielo inmediatamente   Puede adquirir filtros nuevos en su tienda y proveedor  habituales y en los centros de atenci  n al cliente autorizados     1  Quite el filtro de aire del montaje de la rejilla delantera  tirando ligeramente del filtro de aire hacia arriba     2  Lave el filtro con agua tibia a menos de 40  C     3  Con cuidado  retire completamente el exceso de agua d  filtro  Cambie el filtro         Antes de limpiar el filtro de ventilaci  n  desconecte la  unidad desenchufando el cable de alimentaci  n de la toma  de la pared o la subbase o desconecte la alimentaci  n en la  caja de fusibles o el interruptor autom  tico  Si utiliza esta  unidad con la puerta de ventilaci  n cerrada  no es  necesario limpiar el filtro de ventilaci  n     1  Extraiga la parte central de la caja tal y como se describe  en Extracci  n frontal     2  Quite los seis tornillos fijando el armaz  n en el manguito  de pared con un destornillador Phillips Head     3  Deslice el armaz  n hacia fuera del manguito de pared lo  suficientemente como para poder tener acceso al fil
11.  Este simbolo le avisa del riesgo de descarga el  ctrica   Este simbolo le avisa de los peligros que podrian danar el  A aparato de aire acondicionado     CoN Este s  mbolo indica notas especiales        Funcio     ADVERTENCIA    La instalaci  n de este aparato se debe realizar de acuerdo con el C  digo El  ctrico Nacional   La rejilla de metal expandida deber  a utilizarse para mejorar el rendimiento en los sistemas de aire  acondicionado PTAC y PTHP   Por motivos de instalaci  n y para mejorar la apariencia  se puede utilizar la rejilla arquitect  nica o de  aluminio en las unidades PTAC y PTHP    EL MANGUITO Y LA REJILLA POSTERIOR     Disponible opcionalmente     DEFLECTOR DE AIRE VERTICAL MONTAJE DEL MANGUITO REJILLA POSTERIOR   Rejilla de ventilaci  n horizontal   Rejilla posterior de aluminio incluida   Rejilla posterior de aluminio           FILTRO DE AIRE    REJILLA DE ENTRADA   Entrada de aire     REJILLA MET  LICA EXPANDIDA   Para un rendimiento superior     32 Aparato de aire acondicionado                P Seguraida Electrica                                                       AVISO    La forma puede ser diferente seg  n su modelo     Utilice el enchufe de la pared    Standard 208 230V  enchufe de 3  L  neas de 15A                                                             Consumo de Energ  a    Utilice un fusible de  15 AMP  o un  nterruptor de 15 AMP                    Es     Standard 208 230V  enchufe de 3  L  neas de 20A    S    Standard 208 230V  enchufe de
12.  Figure B     5  Clean and replace the filter by reattaching the hook  to the bottom of the vent door and replacing the two  screws  slide the chassis back into the wall sleeve   secure it in place with six screws and reinstall the  front cabinet        Owner s Manual 21    Maintenance and Service        The base pan may overflow due to high humidity     To drain the excess water  remove the drain cap  from the back of the unit     Drain Cap       CI    The chassis must be cleaned every four months or more often as the atmospheric conditions  require  Use water and detergent to clean the basepan  center partition and coils  The use of harsh  cleaning materials may cause a deterioration of the coil fins or endplates  Do not use a high  pressure cleaner as it could cause severe damage to the PTAC fins and coils  A hose is okay to use  to clean the coils  but make sure to cover the control with a blanket or plastic bag to keep it dry     Corrosion Resistant units operating in harsh atmospheric conditions must be removed from the  sleeve and cleaned every 3 months in the same manner as above        Compressor   Fan      The compressor and fan motor are hermetically sealed  permanently lubricated  and require no  additional oiling     Cabinet Front      The cabinet front and discharge air grille can be cleaned with a mild soap or detergent  Under no  circumstances should hydrocarbon based cleaners  e g  acetone  benzene  naphtha  gasoline  etc    be used to clean the front or air 
13.  Limit 2  Temperature Limit 3    PTAC PTHP  UNIT TYPE    e TEMPERATURE LIMITING    Temperature Limiting can save money by limiting the lowest temperature for cooling and the highest  temperature for heating  The temperature limiting is controlled by switches  1    3                                                                                                        This temperature limiting is not available with the Remote Wall Thermostat   Temperature   Temperature   Temperature Cooling Operation Heating Operation  Limit  1 Limit  2 Limit  3 Lowest Temp    Highest Temp    Lowest Temp    Highest Temp   OFF OFF OFF 54   F  12 2   C  86   F  30 0   C  54   F  12 2   C  86   F  30 0   C  ON OFF OFF 56   F  13 3   C  86   F  30 0   C  54   F  12 2   C  84   F  28 9   C  OFF ON OFF 58   F  14 4   C    86  F  30 0   C    54  F  12 2  C    82  F  27 8  C  ON ON OFF 60   F  15 5   C  86   F  30 0   C  54   F  12 2   C  80   F  26 7   C  OFF OFF ON 62   F  16 6   C  86   F  30 0   C  54   F  12 2   C  78   F  25 5   C  ON OFF ON 64   F  17 7   C    86  F  30 0   C    54  F  12 2  C    76  F  24 4  C  OFF ON ON 66   F  18 9   C  86   F  30 0   C  54   F  12 2   C  74   F  23 3   C  ON ON ON 68   F  20 0   C  86   F  30 0   C  54   F  12 2   C  72   F  22 2  C   6  7 Unit Type   OFF OFF Cooling Electric Heater Heat Pump   OFF ON Cooling Electric Heater   ON OFF Heat Pump Only   ON ON Cooling Only                16 Room Air Conditioner       e REMOVING THE FRONT GRILLE    Additional co
14.  PRECAUTION      Contact an authorized service technician for repair or  maintenance of this unit    e Contact the installer for installation of this unit      The air conditioner is not intended for use by young  children or invalids without supervision       Young children should be supervised to ensure that  they do not play with the air conditioner      When the power cord is to be replaced  replacement  work shall be performed by authorized personnel  only using only genuine replacement parts       Installation work must be performed in accordance  with the National Electric Code by qualified and  authorized personnel only     Safety Precautions    E Safety Precautions    To prevent injury to the user or other people and property damage  the following instructions    must be followed   E Incorrect operation due to ignoring instruction will cause harm or damage  The seriousness    is classified by the following indications          AWARNING This symbol indicates the possibility of death or serious injury       A CAUTION This symbol indicates the possibility of injury or damage to properties only           E Meanings of symbols used in this manual are as shown below        D Don t do this       dd Be sure to follow the instruction     AWARNING    E Installation                   Don t use a power cord  a Always plug into a grounded Do not modify or extend the  plug  or a loose socket outlet  power cord length   which is damaged       It may cause a fire or electrical   lt 
15.  casa   El cliente debe hacer verificar el circuito por un  electricista calificado para asegurarse que el  receptor esta debidamente neutralizado     Desconecte el cord  n de energ  a del adaptador   utilizado una mano en cada uno  De lo contrario  la  terminal del adaptador puede romperse  NO UTILICE el  aparato con un enchufe roto     B  SITUACIONES EN LAS CUALES EL APARATO  ES DESCONECTADO CON  FRECUENCIA   No utilice un adaptador en estas circunstancias   Desconectar el cord  n de energ  a con frecuencia lo  llevar   al eventual rompimiento de la terminal de  neutralizaci  n  La saluda de energ  a de la pared  debe ser reemplazada por una salida de tres  patas neutralizada      USO DE EXTENSIONES   Debido al peligro potencial  no recomendamos la  utilizaci  n de extensiones  Sin embargo  si usted  desea utilizar una extensi  n  utilice una  certificada por CSA UL de tres alambres   catalogada 15A  125V     Instalaci  n    E Instalaci  n       AAPRECAUCION    Dimensiones del aparato de aire acondicionado   e Tenga cuidado con los bordes afilados que podr  an  cuasar cortes graves      Al levantar el aparato de aire acondicionado  tenga en  cuenta que es PESADO  Ser  n necesarias 2 personas  para levantarlo         1 066 mm      0    Mida las dimensiones de la pared para el manguito  existente    Para obtener el mejor rendimiento  instale el nuevo  aparato de aire acondicionado de acuerdo con estas  instrucciones de instalaci  n  Todos los manguitos de  pared utilizados pa
16.  cuidado al No use el cable de alimentaci  n  los productos  desembalar e instalar el cerca gas inflamable o  aparato  materiales combustibles tales    como la gasolina  benceno   disolvente  etc     e Puede ocasionar fallos y una   Los bordes afilados pueden e Podr  a ocurrir una explosi  n o  descarga el  ctrica  provocar lesiones  incendio        Manual del propietario 27    Precauciones de Seguridad    E Operaci  n    No use el cable de alimentaci  n No comparta el Saque el enchufe en caso de  cerca gas inflamable o materiales tomacorriente con otros necesidad  sosteniendo la  combustibles tales como la electrodom  sticos  cabeza del enchufe y no lo  gasolina  benceno  disolvente  etc  toque con las manos mojadas   e Puede ocasionar una explosi  n   De lo contrario  puede provocar una   De lo contrario  podr  a provocar un    o descarga el  ctrica  descarga el  ctrica o incendio debido incendio o descarga el  ctrica       a la generaci  n de calor             Y  No ponga el cable de No permita que entre agua Utilice un pa  o suave para  alimentaci  n cerca de un en las piezas el  ctricas  limpiar  No utilice cera   calentador  disolventes o detergentes fuertes     Puede ocasionar un incendio y   Puede provocar fallos en el e La apariencia del aparato de aire  una descarga el  ctrica  producto o descargas acondicionado puede deteriorar   el  ctricas  cambiar el color o desarrollar flujos en  las superficies  Y    PAE  l wy mm   Desenchufe la unidad si oye No abra la parril
17.  edges    2  Do not use water to clean inside the air conditioner  Exposure to water can  destroy the insulation  leading to possible electric shock    3  When cleaning the unit  first make sure that the power and breaker are turned  off  The fan rotates at a very high speed during operation  There is a  possibility of injury if the unit   s power is accidentally triggered on while  cleaning inner parts of the unit     Service    For repair and maintenance  contact your authorized service dealer     Owner s Manual 7    Introduction    E Introduction       A This symbol alerts you to the risk of electric shock   This symbol alerts you to hazards that could cause harm to  A the air conditioner       opp 014 This symbol indicates special notes        A WARNING    This appliance should be installed in accordance with the National Electric Code    Expanded Metal Grille Should be applied for better performance in PTAC and PTHP Units    For Installation purpose and better appearance Aluminium or Architectural grille can be applied in  PTAC and PTHP Units     THE SLEEVE AND THE REAR GRILLE     Available as an option   VERTICAL AIR DEFLECTOR    SLEEVE ASSEMBLY   Horizontal Louver      Including Aluminum Rear Grille        REAR GRILLE   Aluminum Rear Grille           AIR FILTER                      INLET GRILLE     Air Intake                    EXPANDED METAL GRILLE   For Superior Performance        8 Room Air Conditioner    a Electrical Safety    Electrical Safety    Power cord may in
18.  el calefactor  Si el interruptor del  panel frontal est   APAGADO  la unidad funcionar   de acuerdo con el ajuste de los controles                                Cable  AWG   Longitud m  xima o       22 600 ft  180 m  Nota  Las siguientes ilustraciones   20 900 ft  270 m  muestran esquemas de la bomba   18 1500 ft  450 m  de calor y del calefactor el  ctrico de   16 2000 ft  610 m  las unidades rectas   respectivamente     Motion Sensor  Motion Sensor  Interruptor de la puerta  Interruptor de la puerta         Control de recepci  n      Control de recepci  n       Esquema de cableado de la  bomba de calor remota            c  o     X Y   w   o                                  u U U N H U                         FD2 FD1 DR2 DR1 MS2 MS1       L                                                         ES       Molex que Alberga Especificaci  n 396 06V  E  GH    TERMOSTATO REMOTO DE PARED GL     w   Si los cables estan conectados  puede controlar la unidad SARE DE CONTROL     con un termostato remoto de pared       Las conexiones del termostato suministran los 24 voltios de CO ERMOSTATO     CA  Si instala el termostato digital electr  nico  aj  stelo en Esquema del cableado de la  24 voltios de CA  Consulte las instrucciones de instalaci  n unidad de refrigeraci  n recta   de este manual para obtener informaci  n acerca del z             termostato remoto de pared     24 Voltios N  24 voltios L                                     Compresor  Calefactor  V  lvula de  inversi  n   V
19.  saver switch  2 is on  This switch is set at continuous fan to provide continuous fan operation in  cool or heat modes  When the switch is off the continuous fan allows continuous circulation of room air and  make the more balanced temperature of the room  When the switch is on the fan is on or off with the    compressor or with the heater     e FRONT DESK CONTROL    When the pair wire is connected to the connector LOand LI  the unit can be turned ON or OFF with a switch  located at the Front Desk Control panel  When the front desk switch is ON  the fan operate according to the  condition of setting without working compressor and heater  When the front desk switch is OFF  the unit can    operate according to the setting of controls                    Wire   AWG Maximum Length   22 600ft 180m    20 900ft 270m    18 1500ft 450m    16 2000ft 610m                             Ee       LO LI GLGH O W YRC       l  o             Front Desk Switch                e REMOTE WALL THERMOSTAT    When the wires are connected  the unit will be    controlled by a remote wall thermostat     The thermostat connections supply the 24 Volt AC   When you install the digital   electronic thermostat   you must set it to the 24 Volt AC  See the installation  Instruction in this manual for the Remote Wall    Thermostat     24 Volt N  24 Volt L  Compressor   Heater   Reversing Valve          High Fam  Low Fan                                  DO 000D0000                LO LI GLGH O W Y R C     Molex Hous
20.  si  el motor est   suelto  c  mbielo  Si el motor emite    zumbidos o escucha ruido en el interior durante el  funcionamiento  c  mbielo        E Voltaje      n Cableado    El compresor no  funciona  pero el  motor del  ventilador si     E Termostato    E Giratorio    E Condensador  Descarga    Revise el condensador  antes de llamar al servicio  t  cnico      E Compresor    E Sobrecarga    Compruebe el voltaje  Consulte los l  mites en la  p  gina de instrucciones  Si no est   dentro de estos  l  mites  llame a un electricista    Compruebe las conexiones del cableado  si est  n  sueltas  repare o cambia el terminal  Si los cables  est  n fuera  consulte el diagrama del cableado para  identificarlos y c  mbielos  Revise la ubicaci  n de los  cables  Si no est  n ubicados de acuerdo con el  diagrama de cableado  corrija la ubicaci  n     Compruebe la continuidad  consulte el diagrama del  cableado para identificar los terminales  Cambie el  interruptor si el circuito est   abierto     Compruebe la posici  n de la palanca si no est   en el  ajuste de refrigeraci  n m  xima  mueva la palanca  hacia delante hasta este ajuste y reinicie la unidad   Compruebe la continuidad del termostato  Cambie el  termostato si el circuito est   abierto     Revise el condensador   Cambielo si no est   dentro de la clasificaci  n de   10  indicaci  n por el fabricante    Cambielo si existe un cortocircuito  si est   abierto o  da  ado      Compruebe si existe un cortocircuito o una conexi  n  a t
21.  the  unit     e Moving parts could cause injury        4 Room Air Conditioner    Use a soft cloth to clean  Do  not use wax  thinner  or a  strong detergent     e The appearance of the air  conditioner may deteriorate   change color  or develop  surface flaws        eo  MAS    yt Tin    If water enters the product  turn  off the the power switch of the  main body of ala Contact    service center after taking the  power plug out from the socket        Turn off the main power  switch when not using it for  a long time     e Prevent accidental startup and    the possibility of injury     v     0        Do not damage or use an  unspecified power cord     Do not operate or stop the  unit by inserting or pulling  out the power plug     e It will cause electric shock or fire     10 OY  roe      e It will cause electric shock or fire  due to heat generation        When gas leaks  open the  window for ventilation  before operating the unit     Hold the plug by the end  when taking it out       lt may cause electric shock and  damage     e Otherwise  it may cause an  explosion and a fire     Safety Precautions    Do not operate with wet  hands or in damp  environment     e It will cause electric shock        Never touch the metal parts  of the unit when removing  the filter     e They are sharp and may cause    injury        Installation    Install the product so that the noise or  exhaust from the outdoor unit may not  cause any damage to the neighbors       Be considerate of your ne
22. 8  C   ON ON OFF 60  F  15 5  C    86  F  30 0  C    54  F  12 2  C    80  F  26 7  C   OFF OFF ON 62  F  16 6  C    86  F  30 0  C    54  F  12 2  C    78  F  25 5  C   ON OFF ON 64  F  17 7  C    86  F  30 0  C    54  F  12 2  C    76  F  24 4  C   OFF ON ON 66  F  18 9  C    86  F  30 0  C    54  F  12 2  C    74  F  23 3  C   ON ON ON 68  F  20 0  C    86  F  30 0  C    54  F  12 2  C    72  F  22 2  C                 Owner s Manual 17    Control Locations    e REMOTE LOCAL CONTROL    When remote local switch  1 is on  it allow the unit to operate by the Remote Wall Thermostat   The unit control by knobs are not available     ENERGY SAVER    The energy saver switch  2 is on  This switch is set at cycle fan to provide continuous fan operation in cool  or heat modes  When the switch is off the continuous fan allows continuous circulation of room air and  make the more balanced temperature of the room  When the switch is on  the fan is on or off with the  compressor or with the heater     FRONT DESK CONTROL    When the pair wire is connected to the connector FD2 and FD1  the unit can be turned ON or OFF with a  switch located at the Front Desk Control panel  When the front desk switch is ON  the fan operates according  to the setting without working compressor and heater  When the front desk switch is OFF  the unit can  operate according to the setting of controls                                                                                                                 
23. 86  F  30 0  C    54  F  12 2  C    80  F  26 7  C   OFF OFF ON 62  F  16 6  C    86  F  30 0  C    54  F  12 2  C    78  F  25 5  C   ON OFF ON 64  F  17 7  C    86  F  30 0  C    54  F  12 2  C    76  F  24 4  C   OFF ON ON 66  F  18 9  C    86  F  30 0  C    54  F  12 2  C    74  F  23 3  C   ON ON ON 68  F  20 0  C    86  F  30 0  C    54  F  12 2  C    72  F  22 2  C                                         Manual del propietario 41    Ubicacion de los controles    e CONTROL REMOTO LOCAL    Si el interruptor remoto local  1 est   encendido  la unidad funcionar   mediante el termostato remoto de  pared  El control de la unidad mediante palancas no est   disponible       AHORRO DE ENERG  A    El interruptor de ahorro de energ  a  2 est   encendido  Este interruptor est   ajustado en ventilador de ciclo  para el funcionamiento continuo del ventilador en los modos de refrigeraci  n y calefacci  n  Si el interruptor  est   apagado  el ventilador continuo permite la circulaci  n continua del aire en la sala y un mayor equilibrio  de la temperatura de la misma  Si el interruptor est   encendido  el ventilador se activa o se desactiva con el  compresor o con el calefactor     e CONTROL DEL PANEL FRONTAL    Si el cable par est   conectado al conector FD2 y FD1  puede ENCENDER o APAGAR la unidad con un  interruptor ubicado en el panel de control frontal  Si el interruptor del panel frontal est   ENCENDIDO  el  ventilador funciona de acuerdo con el ajuste sin activar el compresor ni
24. AC  debe existir    una sub base     Manual del propietario 33         m  un     UY   gt      O  Ba       Seguraida Electrica       Segur     IMPORTANTE     FAVORLEA CON ATENCI  N     POR LA SEGURIDAD PERSONAL DEL USUARIO   ESTE APARATO DEBE SER DEBIDAMENTE  NEUTRALIZADO     El cord  n de energ  a de   ste aparato esta equipado  con tres patas cable a tierra   Utilice   ste con un  enchufe de pared de tres salidas a tierra  para  minimizar el peligro de choque el  ctrico  El cliente  debe revisar el receptor de pared y el circuito por un  electricista calificado para asegurarse que la  recepci  n esta debidamente neutralizada     NO CORTE O REMUEVA LA TERCERA  PATA GROUND  DEL ENCHUFE     A  SITUACIONES EN LAS CUALES EL APARATO  ES DESCONECTADO  OCASIONALMENTE     Debido al peligro potencial  nosotros no  recomendamos el uso de adaptadores  Sin  embargo  si usted desea utilizar un adaptador  una  CONEXI  N TEMPORAL  puede ser   efectuada  Utilice adaptadores UL  disponibles en la  mayor  a de los estable cimientos de   herramientas  La pata mas grande del adaptador  debe ser alineada con la pata mas grande del  interruptor para asegurarse una polarizaci  n  adecuada     34 Aparato de aire acondicionado    AAPRECAUCION    Adaptar la terminal del ground del adaptador a  la cubierta de la pared con un   tornillo no neutraliza el aparato a menos que la  cubierta del tornillo sea de metal  u no sea  insolada  y el receptor de pared este  neutralizado a trav  s del alambrado del la
25. Cuando haya un escape de No toque las partes   cabeza al sacarlo  gas  abra la ventana para met  licas del aparato al  ventilar antes de poner en sacar el filtro del aire   marcha la unidad     e Podr  a ocasionar una descarga   De lo contrario  podr  a ocurrir e Son puntiagudas y pueden  el  ctrica y da  os  una explosi  n o incendio  provocar lesiones             EN    AU        8     XS       PRECAUCION    E Instalaci  n    Instale el producto de modo que el ruido o Mantenga nivelado el producto al instalarlo   el aire caliente producido por la unidad  externa no moleste a los vecinos       De lo contrario puede dar lugar a disputas e De lo contrario se podr  a causar vibraciones o  vecinales  escapes de agua        Manual del propietario 29    Precauciones de Seguridad    E Operaci  n    No ponga plantas ni animales en No bloquee la entrada ni la salida Utilice un pa  o suave para    la trayectoria que recorrer   elaire del flujo de aire  limpiar  No utilice cera   caliente  disolventes o detergentes fuertes   e Podr  a ocasionar lesiones  e Puede causar una aver  a en el aparato     La apariencia del aparato de aire    acondicionado puede deteriorar  cambiar el  color o desarrollar flujos en las superficies        No se suba a la unidad Inserte siempre el filtro No beba el agua que drena el  interior exterior ni coloque correctamente  aparato de aire acondicionado   objetos sobre la misma  Limpielo cada dos semanas       Puede lesionarse al caerse del aparato o    El fun
26. OWER SWITCH y desconecte el  cable de alimentaci  n     1  Extraiga la rejilla delantera     2  Para extraer la rejilla delantera  tire de la parte  inferior de la misma hacia fuera y despu  s  hacia arriba    Vuelva a instalar el componente siguiendo el  procedimiento de extracci  n     3  Para cambiar la rejilla delantera  coloque las  leng  etas sobre la parte superior de la unidad y  presione la parte inferior de la rejilla delantera  hasta que las abrazaderas queden encajadas  en su sitio     e Este aparato de aire acondicionado  PTAC   descarga aire desde la parte superior de la  unidad a trav  s de rejillas de ventilaci  n de  descarga de 2 posiciones  La unidad se  suministra de f  brica con las rejillas de  ventilaci  n de descarga en un   ngulo de 40   en  posici  n vertical  De forma alternativa  las rejillas  de ventilaci  n estar  n en un   ngulo de 15   en  posici  n vertical           Tornillos  Para ajustar la direcci  n del aire  extraiga la rejilla EEE  delantera  Quite los 4 tornillos y fije la rejilla de  descarga en la rejilla delantera                                                                                                                                         Gire la rejilla de descarga 180   y despu  s vuelva  a fijar la rejilla de descarga en la rejilla delantera  con los 4 tornillos     44 Aparato de aire acondicionado    Mantenimiento y asistencia t  cnica    E Mantenimiento y asistencia t  cnica    APAGUE EL APARATO DE AIRE ACONDICIONADO Y
27. XTRACCI  N DE LA REJILLA DELANTERA    Los controles adicionales est  n disponibles al extraer la  rejilla delantera y la tapa opcional de la caja de controles   Para extraer la rejilla delantera  tire de la parte inferior de  la misma y despu  s hacia arriba    Para cambiar la rejilla delantera  coloque las leng  etas  sobre la parte superior de la unidad y presione la parte  inferior de la rejilla delantera hasta que las abrazaderas  queden encajadas en su sitio     CONTROLES ADICIONALES    Los controles adicionales est  n ubicados detr  s de la tapa opcional de la caja de controles  El ajuste  est  ndar es la posici  n OFF  El t  cnico autorizado deber   revisar los interruptores y asegurarse de que  est  n en la posici  n correcta     REMOTO ON ON ON ON    ODO     LOCAL OFF OFF OFF OFF OFF OFF  Remoto Local A R 9 4 5 E i  Ahorro de energ  a      L  mite de temperatura 1         Limite de temperatura 2  Limite de temperatura 3  PTAC PTHP  TIPO DE UNIDAD       LIMITACI  N DE TEMPERATURA    Puede ahorrar dinero limitando la temperatura al m  nimo para la refrigeraci  n y al m  ximo para la  calefacci  n  La limitaci  n de la temperatura se controla con los interruptores  1    3  Esta limitaci  n de  temperatura no est   disponible en el termostato remoto de pared                                                                                                                                                                 L  mite de L  mite de L  mite de Funcionamiento de la re
28. cci  n con funcionamiento del  ventilador a velocidad alta     LAN   b c  TILA    ERRADO  VENTILADOR  SA ABIERTO    La palanca de ventilaci  n est   ubicada en el lateral  izquierdo inferior de la unidad    La palanca de ventilaci  n debe estar en la posici  n  CLOSE para mantener las condiciones de refrigeraci  n    ptimas  Si necesita aire fresco en la sala  ajuste la  palanca de ventilaci  n en la posici  n OPEN  El  regulador est   abierto y el aire exterior entra en la sala   Esto reducir   la eficacia de la refrigeraci  n o la  calefacci  n                   AAPRECAUCION    Si el aparato de aire acondicionado ha estado en  funcionamiento y se apaga o se ajusta en la posici  n  de ventilador  espere durante unos 3 minutos antes  de restablecer la operaci  n de refrigeraci  n     Nota  Es posible que note un ligero olor a  calefacci  n desde la unidad la primera vez  que lo ajuste en HEAT despu  s de la  estaci  n estival    lt None gt Este olor  debido a la existencia de  finas part  culas de polvo en la calefacci  n   desaparecer   r  pidamente  Esto es  inofensivo     Manual del propietario 37    Ubicacion de los controles       Los controles tendr  n el siguiente aspecto     FAN SPEED    Cada vez que pulse este bot  n  se desplazar   por los ajustes de la siguiente forma    High F2   gt  Low F1   gt  High F2   gt  Low F1          o  E SAVE    o  HEAT    q   Li    F1 LOW    F2HIGH FAN rr POWER     Para ENCENDER el aparato de aire  acondicionado  pulse este bot  n  Para
29. cionamiento sin filtros puede  al caerse los objetos que haya colocado  provocar fallos        Tenga cuidado para no tocar los Evite un enfriamiento excesivo y No introduzca la mano ni barras en    bordes puntiagudos al instalar  ventile en ocasiones  la entrada o salida del aire durante  el funcionamiento del aparato     Podr  a ocasionar lesiones    De lo contrario  podr  a da  ar su salud     De lo contrario  podr  an ocurrir lesiones    personales        Si entra l  quido de las pilas en contacto con la pielo Si el l  quido de las pilas alcanzara su boca  cepille sus    ropa  l  vela inmediatamente con agua  No utilice el dientes y consulte a un m  dico No utilice el mando a  mando a distancia si las pilas tienen fugas  distancia si las pilas han experimentado fugas    e Los productos qu  micos de las pilas podr  an causar e Los productos qu  micos de las pilas podr  an causar  quemaduras u otros perjuicios a la salud  quemaduras u otros perjuicios a la salud        30 Aparato de aire acondicionado    Antes de poner el equipo en funcionamiento    E Antes de poner el equipo en funcionamiento    Preparaci  n p    1  P  ngase en contacto con un especialista para realizar la instalaci  n    2  Enchufe correctamente la toma de alimentaci  n    3  Utilice un circuito dedicado    4  No utilice un cable alargador    5  No inicie cese el funcionamiento enchufando desenchufando el cable el  ctrico   6  Si el cable enchufe est   da  ado  sustit  yalo solo por una pieza autorizada   
30. clude a current  interrupter device  A test and reset                                                                                              NOTICE    The shape may be different according to its model     Use Wall Receptacle Power Supply    Use 15 AMP  time  delay fuse or 15 AMP   Circuit breaker   Standard 208 230V  3 wire  grounding receptacle rated 15A    Use 20 AMP  time   delay fuse or 20 AMP   Circuit breaker     2500W Heater  gt  15 AMP  Circuit Breaker     Standard 208 230V  3 wire  grounding receptacle rated 20A    Use 30 AMP  time  delay fuse or 30 AMP   Circuit breaker   Standard 208 230V  3 wire  grounding receptacle rated 30A    Use 20 AMP  time delay  fuse or 20 AMP   Circuit breaker    2000W Heater  gt  15 AMP  Circuit Breaker     Standard 265V grounding  receptacle rated 20A    Use 30 AMP  time delay  fuse or 30 AMP  Circuit breaker    Standard 265V grounding  receptacle rated 30A          NOTICE    DO NOT USE AN EXTENSION CORD on 230  208   and 230 208 265Volt units    All wiring should be made in accordance with local  electrical codes and regulations    Aluminum house wiring may pose special problems   Consult a qualified electrician           button is provided on the plug case  The  device should be tested on a periodic  basis by first pressing the TEST button  and then the RESET button  If the TEST  button does not trip or if the RESET  button will not stay engaged   discontinue use of the air conditioner  and contact a qualified service  technicia
31. cool  and retest    E Fan motor   If not running  determine the cause  Replace if  Compressor pene ee required   cycles on E Condenser air flow    Remove the cabinet  inspect the interior surface of the  overload  restriction condenser  if restricted  clean carefully with a vacuum  cleaner  do not damage fins  or brush  Clean the  interior base before reassembling   E Condenser fins   If condenser fins are closed over a large area on the   damaged  coil surface  head pressures will increase  causing the  compressor to cycle  Straighten the fins or replace the  coil   E Capacitor e Test capacitor   E Wiring e Check the terminals  If loose  repair or replace   E Refrigerating system e Check the system for a restriction   E Air filter   If restricted  clean or replace   Insufficient MExhaust damper door   Close if open     cooling or heating    Unit undersized    e Determine if the unit is properly sized for the area to  be cooled        Excessive noise     Cross flow fan    Copper tubing    e Check the set screw or clamp  If loose or missing   correct  If the blower or fan is hitting air guide   rearrange the air handling parts     e Carefully rearrange tubing not to contact  compressor   shroud  and barrier        ROOM AIR CONDITIONER VOLTAGE LIMITS             NAME PLATE RATING MINIMUM MAXIMUM  208 230 V 187 V 253 V  265 V 238 V 292 V                Owner s Manual 25    Manual del usuario del acondicionador de aire tipo Ventana    TABLA DE CONTENIDOS       Precauciones de Seg
32. d with the box  AIR  Refer to the diagram below  i Bibble 1  Over 20   1  Take out the insulation strip from the upper packing   i i   F 280 mm i    2  Attach the insulation strip onto the rear upper side of  11   Front  nsulation Strip           the wall sleeve    3  If anyone would like to improve unit energy efficiency   it is recommended the change of outside grille for an  unit protection and an addition of a plastic rear grille    This is optional          Sleeve          Rear    Owner s Manual 11    Installation    e UNIT INSTALLATION    1  Remove the shipping screw from the ventilation door     2  Remove the front gille by pulling it out at the bottom  to release it  then lift it up along the unit top front        3  Slide the unit into the wall sleeve and secure with  6 screws through the unit flange holes     4  Reinstall the front grille by hooking the top over the  unit top  then pushing it in at the bottom        12 Room Air Conditioner    B Control Locations    TEMPERATURE       TEMPERATURE CONTROL   Set the Thermostat control to the desired  temperature mark 5  the mid point is a good  starting position   If the room temperature is not  satisfactory after a reasonable time  adjust the  control to a cooler or warmer setting  as  appropriate     e VENTILATION    The ventilation lever is located to the lower left side   of the unit    The ventilation lever must be in the CLOSE position in  order to maintain the best cooling conditions    When fresh air is necessar
33. de la clasificaci  n de  10   probarlo   indicaci  n por el fabricante  C  mbielo si existe un  cortocircuito  si est   abierto o da  ado     E No gira e El alabe del ventilador golpea la cubierta o el ventilador  de flujo transversal golpea el rollo  Vuelva a alinear el  montaje     e Las unidades que utilizan ventiladores de condensador  de anilla deben tener una holgura de entre 0 63 cm y  0 78 cm hasta la base  Si golpea la base  eleve la parte  inferior del motor del ventilador con tornillos de montaje     e Revise los cojinetes del motor del ventilador  si el eje del  motor no gira  cambie el motor        E Gira en sobrecarga e Compruebe el voltaje  Compruebe los limites en esta  p  gina  Si no est   dentro de los l  mites  llame a un  electricista     El motor del   Condensador de prueba   ventilador Compruebe los cojinetes    Gira correctamente el   labe  funciona de forma del ventilador     intermitente Si no es as    cambie el motor del ventilador   e Preste atenci  n a cualquier cambio que se produzca de    alta velocidad a baja velocidad  Si la velocidad no  cambia  cambie el motor        Manual del propietario 47    Mantenimiento y asistencia t  cnica       Ruido en el motor    del ventilador    E Arandelas aislantes    E Cojinetes gastados    e Revise las arandelas aislantes  si est  n gastadas o  faltan  c  mbielas     e Si est  n agrietadas  desequilibradas o faltan algunas   c  mbielas      Apri  telas    e Si los ruidos contin  an durante el funcionamiento o
34. e la puerta de  ventilaci  n     2  Para ello  quite la rejilla delantera tirando de ella  hacia fuera desde la parte inferior y  a continuaci  n   lev  ntela por encima de la parte delantera de la  unidad     3  Deslice la unidad hacia el interior del manguito de  pared y f  jela con 6 tornillos que deber   introducir por  los orificios de la abrazadera de la unidad     4  Vuelva a instalar la rejilla delantera enganchando la  parte superior sobre la parte superior de la unidad y   a continuaci  n  presione en la parte inferior     36 Aparato de aire acondicionado          Ubicaci  n de los controles    B Ubicaci  n de los controles       Controles mar  TEMPERATURE OPERATION  CONTROL DE TEMPERATURA SELECTOR DEL MODO DE FUNCIONAMIENTO  Ajuste el control del termostato en la marca 5ala OFF Para apagar el aire acondicionado   temperatura que desee  el punto medio es una LOW FAN Funcionamiento del ventilador a velocidad  posici  n adecuada de inicio   Si la temperatura baja sin refrigeraci  n     ambiente no es satisfactoria despu  s de un tiempo HIGH FAN  razonable  ajuste el control en un punto m  s fr  o o  m  s caliente  seg  n el caso     Funcionamiento del ventilador a velocidad  alta sin refrigeraci  n     LOW COOL Refrigeraci  n con funcionamiento del  ventilador a velocidad baja     HIGH COOL Refrigeraci  n con funcionamiento del  ventilador a velocidad alta       VENTILACI  N LOW HEAT Calefacci  n con funcionamiento del  ventilador a velocidad baja     HIGH HEAT Calefa
35. e las sujeciones encajen en su lugar  correspondiente        e CONTROLES COMPLEMENTARIOS    Los controles complementarios est  n ubicados detr  s de la cubierta opcional del cuadro de control  Las  configuraciones est  ndares estar  n en la posici  n OFF  El personal de mantenimiento autorizados deber    comprobar los conmutadores y asegurar que est  n en la posici  n adecuada        REMOTE ON ON ON ON    ON  OFF  LOCAL OFF OFF OFF OFF  3 4 5    1 2  A distancia   Local     Ahorro de energia    L  mite de temperatura 1  L  mite de temperatura 2    Limite de temperatura 3                  LIMITACI  N DE LA TEMPERATURA    La funci  n de limitaci  n de temperatura puede ahorrar dinero al limitar la temperatura m  s baja para la                                  refrigeraci  n y la m  s alta para la calefacci  n  La limitaci  n de temperatura viene controlada por los   conmutadores 1     3    Esta limitaci  n no se encuentra disponible en el termostato de la pared   L  mite de L  mite de L  mite de Funcionamiento de la refrigeraci  n   Funcionamiento de la calefacci  n   temperatura  1   temperatura  2   temperatura  3 Temperatura m  s baja   Temperatura m  s alta   Temperatura m  s baja   Temperatura m  s alta  OFF OFF OFF 54F  12 2  C    86  F  30 0  C    54  F  12 2  C    86  F  30 0  C   ON OFF OFF 56  F  13 3  C    86  F  30 0  C    54  F  12 2  C    84  F  28 9  C   OFF ON OFF 58  F  14 4  C    86  F  30 0  C    54  F  12 2  C    82  F  27 8  C   ON ON OFF 60  F  15 5  C    
36. e los controles                                         LO LI GL GH O W  l ooh Ela                   del        e TERMOSTATO REMOTO DE PARED   es est  n conectados  la unidad  se podr   controlar a trav  s del termostato de la pared   El suministro el  ctrico para las conexiones del  termostato es de 24 Volt AC  Cuando se instale el  termostato electr  nico   digital  se deber   establecer en  24 Volt AC  Consulte el proceso de instalaci  n del    Toda vez qu       Y RC     onmutador  la parte delantera       e los cab    Conectado    AWG Largos M  ximo   22 600ft 180m    20 900ft 270m    18 1500ft 450m    16 2000ft 610m        termostato de la pared Termostato     24 Volt N  24 Volt L  Compresor                      LO LI GL GH     Molex que Al    Calefacci  n  V  lvula de inversi  n  Ventilaci  n alta  Ventilaci  n baja   a   DO DO    Ow YRC          berga Especificaci  n 396 09V        Nota  Las siguientes cifras muestran la  esquem  tica de cableado para unidades  con bomba de calor y enfriamiento directo  con calor el  ctrico respectivamente     Esquem  tica de cableado  para una bomba de calor remota                Conexiones del  panel de control       Conexiones  del termostato  Esquem  tica de cableado  para una unidad de enfriamiento directa                                    Conexiones del  panel de control    Conexiones  del termostato    Manual del propietario 43    Ubicacion de los controles         Antes de realizar el desmontaje  ajuste en OFF el interruptor P
37. entilador alto                                    Ventilador 5    bajo  CI eC E CONEXIONES DEL  PANEL DE CONTROL                                                       GLGH O W Y RC    Lado      Molex que Alberga Especificaci  n 396 07V  O ERMOSTATO                42 Aparato de aire acondicionado    e CONTROL REMOTO LOCAL    Si el conmutador 1 a distancia   local esta en ON  la unidad podra funcionar a trav  s del control a distancia    del termostato de la pared     No se encuentra disponible un control de la unidad a trav  s de botones        AHORRO DE ENERG  A  El conmutador 2 de ahorro de energ  a est   en ON  Este conmutador se establece en ventilador continuo  para ofrecer el funcionamiento de   ste en los modos de calor y fr  o  Si el conmutador est   en OFF  el    ventilador har   que el aire de la habitaci  n circule de forma continua para equilibrar la temperatura de la  habitaci  n  Cuando el conmutador est   en ON  el ventilador se encontrar   en ON u OFF con el compresor o    la calefacci  n    e  CONTROL DEL PANEL FRONTAL  Si el cable par est   conectado al conector LO y LI  la unidad puede encenderse o apagarse con el conmutador    ubicado en el panel de control de la parte delantera   Si el conmutador de la parte delantera est   en ON  el ventilador funcionar   de acuerdo con la configuraci  n sin que    tenga que funcionar el compresor o la calefacci  n        Si el conmutador de la parte delantera est   en OFF  la unidad funcionar   seg  n la configuraci  n d
38. ervice costs                 No other warranty is applicable to this product  THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY   EXPRESS OR IMPLIED  INCLUDING WITHOUT LIMITATION  ANY WARRANTY OF MERCHANTABILITY OR FITNESS  FOR A PARTICULAR PURPOSE  TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW  IT IS LIMITED  IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE  NEITHER THE MANUFACTURER NOR ITS U S   DISTRIBUTOR SHALL BE LIABLE FOR ANY INCIDENTAL  CONSEQUENTIAL  INDIRECT  SPECIAL  OR PUNITIVE  DAMAGES OF ANY NATURE  INCLUDING WITHOUT LIMITATION  LOST REVENUES OR PROFITS  OR ANY OTHER  DAMAGE WHETHER BASED IN CONTRACT  TORT  OR OTHERWISE  Some states and or territories do not allow the  exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts  so  the above exclusion or limitation may not apply to you  This warranty gives you  the original purchaser  specific legal  rights and you may also have other rights that vary from state to state or territory to territory     THIS LIMITED WARRANTY DOES NOT APPLY TO     1  Service trips to your home for delivery or pickup  install  instruct or replace house fuses  or connect  house wiring or plumbing  or correction of unauthorized repairs     2  Failure of product to perform during power failures and interruptions or inadequate electrical service    3  Damage caused by transportation or handling    4  Damage to the product caused by accident  vermin  lightning  winds  fire  flo
39. frigeraci  n Funcionamiento de la calefacci  n  temperatura  1  temperatura  2 temperatura  3  Temperatura m  s baja  Temperatura m  s alta   Temperatura m  s baja   Temperatura m  s alta  OFF OFF OFF 54   F  12 2  C    86  F  30 0  C    54  F  122  C    86  F  30 0 C   ON OFF OFF 56  F  13 3   C    86  F  30 0  C    54  F  122  C    84  F  28 9   C   OFF ON OFF 58  F  14 4  C    86  F  30 0  C    54  F  122  C    82  F  27 8  C   ON ON OFF 60  F  15 5  C    86  F  30 0  C    54  F  122  C    80  F  26 7  C   OFF OFF ON 62  F  16 6  C    86  F  30 0  C    54  F  122  C    78  F  25 5   C   ON OFF ON 64  F  17 7  C    86  F  30 0   C    54  F  122  C    76  F  24 4   C   OFF ON ON 66   F  18 9  C    86  F  30 0  C    54  F  122  C    74  F  23 3   C   ON ON ON 68   F  20 0  C    86  F  30 0  C    54  F  122  C    72  F  22 2  C    6  7 Tipo de unidad  OFF OFF Refrigeraci  n Calefacci  n el  ctrica Bomba de calor  OFF ON Refrigeraci  n Calefacci  n el  ctrica  ON OFF S  lo bomba de calor  ON ON S  lo refrigeraci  n                   40 Aparato de aire acondicionado    Ubicaci  n de los controles    e RETIRE LA REJILLA DELANTERA    Existen m  s controles si retira la rejilla delantera y la cubierta  opcional del cuadro de control    Para retirar la rejilla delantera  saque la parte inferior de la  rejilla delantera y lev  ntela    Para sustituir la rejilla delantera  sit  e las pesta  as en la parte  superior de la unidad y presione sobre la parte inferior de la  unidad hasta qu
40. grilles     Use care when cleaning the control area  Do not use an excessively wet cleaning cloth        Corrosion resistant models subjected to harsh seacoast environments must be removed from the  wall sleeve and completely flushed with clean water at least four times a year  The basepan  center  partition  condenser end plates  and the condenser itself should be sprayed with clean  fresh water   Leaving the unit in the sleeve and simply spraying the outdoor grille is not sufficient     22 Room Air Conditioner    Maintenance and Service       Troubleshooting Tips save time and money   Review the chart below first and you may not need to call for service     Normal O      You may hear a pinging noise caused by water being picked up and thrown by the slinger fan against the  condenser on rainy days or when the humidity is high  This design feature helps remove moisture and  improve efficiency    e You may hear the thermostat click when the compressor cycles on and off      Water will collect in the base pan during high humidity or on rainy days  The water may overflow and drip  from the outdoor side of the unit      The fan may run even when the compressor does not              E No power   Check voltage at outlet  Correct if none   E Power supply cord e Check voltage to rotary switch  If none  check power  supply cord  Replace cord if circuit is open   E Rotary switch e Check switch continuity  Refer to wiring diagram for  terminal identification  Replace switch if defective
41. ierra en el compresor  Si est   abierto o conectado  a tierra  cambie el compresor     Compruebe si existe sobrecarga en el compresor  si  est   montado en el exterior  C  mbielo si est   abierto    Si la temperatura del compresor es alta  libere la  sobrecarga  enfrielo y reinicielo         48 Aparato de aire    acondicionado       Mantenimiento y asistencia t  cnica       Ciclos del  compresor en  sobrecarga     E Voltaje    E Restricci  n de flujo de aire    en el condensador    E Aletas del condensador   da  adas     E Condensador  E Cableado    E Sistema de refrigeraci  n      Compruebe el voltaje  Consulte los limites en la  p  gina de instrucciones  Si no est   dentro de los  l  mites  llame a un electricista     e Compruebe si existe sobrecarga  si est   montado en  el exterior  C  mbielo si est   abierto   Si la temperatura  del compresor es alta  quite la sobrecarga  enfr  elo y  rein  cielo      e Si no funciona  determine la causa  C  mbielo si es    necesario      Quite el armario  revise la superficie interior del  condensador  si est   restringida  limpiela  cuidadosamente con una aspiradora  no da  e las    aletas  o un cepillo  Limpie la base interior antes de  volver a montarlo       Si las aletas de condensador permanecen cerradas  en una zona amplia de la superficie de la bobina  la  presi  n del cabezal aumentar    lo que provocar   un  ciclo del compresor  Refuerce las aletas o cambie la  bobina        E Condensador de prueba    e Compruebe los terminale
42. ighbor     Be sure the product is level front to back  and side to side when installing     e It may cause vibration or water leakage        Owner s Manual 5    Safety Precautions    E Operation    Do not put a pet or house plant Do not block the inlet or outlet of Use a soft cloth to clean  Do not  where it will be exposed to direct air flow  use wax  thinner  or a strong  air flow  detergent   e It is not good to sit in the draft  e lt may cause product failure  e The appearance of the air conditioner  may deteriorate  change color  or    develop surface flaws        Y      4  Do not step on the indoor outdoor Always insert the filter securely  Do not drink water drained from    unit and do not put anything on it  Clean it every two weeks  the air conditioner   e lt may cause an injury through dropping    Operation without filters will cause e It contains every contaminant  of the unit or falling down  failure  condensed from the air and could cause    health issues        Be cautious not to touch the Avoid excessive cooling and Do not insert hands or other  sharp edges when installing  perform ventilation sometimes  objects through the air inlet or  outlet during operation     A severe cut or other injury could result    Use the ventilation function to circulate   Electrical and moving parts could cause  air without cooling or heating shock or injury        If the liquid from the batteries gets onto your skin or If you eat the liquid from the batteries  brush your teeth  c
43. inal  The wall  power outlet should be replaced by a three slot   grounding  outlet instead     USE OF EXTENSION CORDS    Because of potential safety hazards  we strongly  discourage the use of an extension cord  However  if  you wish to use an extension cord  use a CSA  certified UL listed 3 wire  grounding  extension cord     Installation    E Installation    How to       44 CAUTION Dimension of air conditioner    There are sharp edges that can cause serious cuts     When lifting the air conditioner  it is HEAVY    Use 2 people to lift         1 066 mm   42    For existing sleeve  you should measure the wall  sleeve dimensions   You can install the new air conditioner according to  these installation instructions to achieve the best  performence  All wall sleeves used to mount the new air  conditioner must be in good structural condition and  have the rear grille that securely attaches to the sleeve  or the flange of the sleeve to secure the new air  conditioner  LZ      To avoid vibration and noise  make sure the unit is Dimension of sleeve assembly  optional     installed securely and firmly  Y    When installing the sleeve  make certain there is  nothing within 20  of the back that would interfere with  heat radiation and exhaust air flow     1066 mm   42      349 tlamm   13 3 4      To maintain the best 4    performance of the LG PTAC  INSULA NON e          an insulation strip must be    ia    aa EAT n        j  attached  The insulation strip          INTAKE  is provide
44. ing Spec 396 09V           Note The following figures show  wiring schematics for heat pump  and straight cool units with electric  heat  respectively     Wiring Schematic for  Remote Heat Pump             CONTROL BOARD  CONNECTIONS       THERMOSTAT  CONNECTIONS    Wiring Schematic for  Straight Cool Unit           CONTROL BOARD  CONNECTIONS    THERMOSTAT  CONNECTIONS    Owner s Manual 19    Control Locations          Before the following disassembly  POWER SWITCH is set to OFF and disconnected the power  cord     1  Remove the front grille    2  To remove the front grille  pull out the bottom of  the front grille and then lift up   Re install the component by referring to the  removal procedure    3  To replace the front grille  place the tabs over  the top of the unit and push the bottom of front  grille until the clips snap into place        e This Room Air Conditioner  PTAC  discharges  air from the top of the unit through reversible  2   position discharge grille louvers  The unit is  shipped from the factory with the discharge grille  louvers at an angle of 40   off vertical  In an  alternate position the louvers will be at an angle  of 15   off vertical        y  To adjust the air direction  remove the front grille     Remove the 4 screws that fasten the discharge  grille to the front grille     Flip the discharge grille 180    then reattach the  discharge grille to the front grille with 4 screws     20 Room Air Conditioner    Maintenance and Service    E Maintenance a
45. la de Si entra agua en el producto   un sonido extra  o  olores  o entrada al aparato mientras apague el interruptor de la carcasa  si observa salir humo  est   en funcionamiento  principal del aparato  P  ngase en    contacto con el centro de servicio  despu  s de haber sacado el  enchufe del tomacorriente       De lo contrario  puede ocurrir   De lo contrario  pueden ocurrir  un incendio y un accidente por descargas el  ctricas y fallos   descarga el  ctrica     K aN  po Q    gt           Ventile bien la sala al usar Apague el aparato y el Apague el interruptor de  este aparato con una estufa  interruptor diferencial alimentaci  n principal cuando  etc  primero antes de limpiar la no vaya a utilizar el aparato  unidad  durante mucho tiempo   e Puede ocurrir un falta de   Debido a que el ventilador gira a   Evitar   el arranque accidental y  ox  geno  alta velocidad durante el la posibilidad de lesiones     28 Aparato de aire acondicionado    Precauciones de Seguridad         No opere ni detenga la No da  e ni use un enchufe No toque el producto con  unidad insertando o de alimentaci  n no las manos mojadas o en un  estirando de enchufe  especificado  ambiente h  medo   e De lo contrario  puede provocar   Provocar   descargas el  ctricas   Provocar   descargas el  ctricas   una descarga el  ctrica o o incendios   incendio debido a la generaci  n  de calor   Y         2 uS Qe  Pre         Gh Ns    Dy   IX g  POOH  Y  DE Keduill es    O 7 AA   N O    Sostenga el enchufe porsu 
46. lothes  wash it well with clean water  Do not use the and see doctor  Do not use the remote if the batteries  remote if the batteries have leaked  have leaked      The chemicals in batteries could cause burns or other health   The chemicals in batteries could cause burns or other health  hazards  hazards     E 0  Fis    6 Room Air Conditioner    Before Operation    E Before Operation        Preparin      Contact an installation specialist for installation   This is NOT a do it yourself project      Plug in the power plug properly      Use a dedicated circuit      Do not use an extension cord  Consult a professional installer or electrician      Do not start stop operation by plugging unplugging the power cord      If the cord plug is damaged  replace it with only an authorized replacement  part      Usage    1  Being exposed to direct airflow for an extended period of time could be  hazardous to your health  Do not expose occupants  pets  or plants to direct  airflow for extended periods of time  In other words  don t sit in the draft    2  Due to the possibility of oxygen deficiency  ventilate the room when used  together with stoves or other heating devices    3  Do not use this air conditioner for non specified special purposes  e g   preserving precision devices  food  pets  plants  and art objects   Such usage  could damage the items      i    aoa WP        1  Do not touch the metal parts of the unit when removing the filter  Injuries can  occur when handling sharp metal
47. may cause a fire or electrical e It will cause electric shock or fire  shock  shock  due to heat generation   Y    29   YA            Do not disassemble or Be caution when unpacking Do not use the power cord near  modify products  and installing  flammable gas or combustibles  such as gasoline  benzene   thinner  etc     Sharp edges may cause   lt may cause explosion or fire     e lt may cause failure and    electric shock  injury        Owner s Manual 3    Safety Precautions    E Operation    Do not place objects on the  poor cord  Protect the cord  rom being pinched or  damaged       There is danger of fire or electric  hock       Do not place the power cord  near a heater     e It may cause fire and electric       Unplug the unit if strange  sounds  odors  or smoke  come from it       It could represent a fire hazed        Ventilate the room well when  using this appliance  together with a stove  etc     e Oxygen depletion could occur     Use a dedicated circuit for  this appliance        An overloaded circuit is a fire    hazard     Take the power plug out if  necessary  holding the end  of the plug and do not touch  it with wet hands       It may cause a fire or electrical  shock        Do not allow water to run  into electric parts     e It will cause failure of machine or    electric shock        Do not open the suction  inlet grill of the product  during operation     e Otherwise  it may electrical    shock and failure     Turn off the power and  breaker when cleaning
48. n           A WARNING    Never push the test button during operation  Otherwise this plug can damaged    This device contains chemicals  including lead  known  to the State of California to cause cancer  birth  defects  or other reproductive harm    Wash hands after handling    Do not remove  modify  or immerse this plug    If this device trips  the cause should be corrected  before further use     A CAUTION    The conductors inside this cord are surrounded by  shields  which monitor leakage current    These shields are not grounded    Periodically examine the cord for any damage  Do  not use this product in the event the shields become  exposed    Avoid shock hazard  This unit cannot be serviced   Opening the tamper resistant  sealed portion of the  unit voids all warranties and performance claims   This unit is not intended to be an ON OFF switch     e If unit equipped with cords and plugs as long as  they are installed with sub bases  and the cord and  plug are enclosed within the sub base    e The sub base must have means for permanent  connection    e The sub base must have an outlet for the connection  of the cord and plug    e To complete the installation of this PTAC  there must  be a sub base     Owners Manual 9    Electrical Safety       IMPORTANT   PLEASE READ CAREFULLY     FOR THE USER S PERSONAL SAFETY  THIS  APPLIANCE MUST BE PROPERLY GROUNDED    The power cord of this appliance is equipped with a  three prong  grounding  plug  Use this with a standard  three sl
49. nd Service    TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET         The air filter should be checked at least twice a month to see if cleaning is necessary   Trapped particles in the filter will build up and block the airflow  This reduces the cooling  capacity and also causes an accumulation of frost on the cooling coils     If the filter becomes turn or damaged you should replace  immediately  Replacement filters are available from your  salesperson  dealer  and the authorized customer service  centers     1  Remove the air filter from the front grille assembly by  pulling the air filter up slightly     2  Wash the filter using lukewarm water below 40   C  104   F      3  Gently shake the excess water from the filter completely   Replace the filter     Before cleaning the vent filter  disconnect power to the  unit by unplugging the power cord at the wall outlet or  subbase  or disconnect power at the fuse box or circuit  breaker  If unit is operated with vent door closed  the  vent filter does not need to be cleaned     1  Remove the cabinet front as described in Front  Removal     2  Remove the six screws securing the chassis to the  wall sleeve with a Phillips Head screwdriver     3  Slide the chassis out of the wall sleeve far enough  so that the vent filter is accessible as shown in  Figure A     4  Remove the vent filter by unscrewing the two screws  at the top of the filter and gently pulling the filter  away from the partition panel  Refer to
50. neer should go fully prepared with the prescribed tools to be used regarding that  problem  lt also keeps the customer aware about the unit    Here are some of the problems defined below for which the LED indicates by flashing number of times  the error has been reconrded against it    The errors are the mentioned in the  Table 13  which is as follows                                         ON Normal  OFF No power   failed board  Fault Codes  CH 01 Indoor Air Thermistor Error  CH 02 Indoor Coil Thermistor Error  CH 03 Outdoor Air Thermistor Error  PTHP Only   CH 04 Outdoor Coil Thermistor Error  PTHP Only   CH 05 Mode Error  CH 06 Setpoint Error  CH 07 Bad Thermistor Wiring       Owner s Manual 15    Control Locations       e REMOVING THE FRONT GRILLE    Additional controls are available after  removing the front grille and option  cover of control box    To remove the front grille  pull out the  bottom of front grille and then lift up    To replace the front grille  place the tabs  over the top of the unit and push the  bottom of front grille until the clips snap  into place         ADDITIONAL CONTROLS    The additional controls are located behind the option cover of control box  The standard settings will be in  the OFF position  The authorized servicer has to check switches and ensure the switches are in the desired    position  REMOTE ON ON ON ON  ON                            OFF  LOCAL Orr OF oF OFF OFF OFF  Remote Local  Energy Saver 2  Temperature Limit 1  Temperature
51. ntrols are available after removing the  front grille and option cover of control box   To remove the front grille  pull out the bottom of front  grille and then lift up   To replace the front grille  place the tabs over the top  of the unit and push the bottom of front grille until the  clips snap into place         ADDITIONAL CONTROLS    The additional controls are located behind the option cover of control box  The standard settings will be in  the OFF position  The authorized service man has to check switches and ensure the switches are in the  desired position     ee a  Energy Saver  Temperature Limit 1  Temperature Limit 2    REMOTE ON ON ON ON            LOCAL OET SER ore QFE    z    Temperature Limit 3       TEMPERATURE LIMITING  Temperature Limiting can save money by limiting the lowest temperature for cooling and the highest  temperature for heating  The temperature limiting is controlled by dip switch  1    3   This temperature limiting is not available with the Remote Wall Thermostat     Control Locations                                                                   Temperature Temperature Temperature Cooling Operation Heating Operation  Limit  1 Limit  2 Limit  3 Lowest Temp    Highest Temp    Lowest Temp    Highest Temp   OFF OFF OFF 54  F  12 2  C    86  F  30 0  C    54  F  12 2  C    86  F  30 0  C   ON OFF OFF 56  F  13 3  C    86  F  30 0  C    54  F  12 2  C    84  F  28 9  C   OFF ON OFF 58  F  14 4  C    86  F  30 0  C    54  F  12 2  C    82  F  27 
52. o n      Es posible que escuche un sonido similar al goteo provocado por el agua que el ventilador recoge y lanza  contra el condensador en d  as lluviosos o cuando los niveles de humedad son muy altos  Esta funci  n del  dise  o ayuda a eliminar la humedad y mejorar la eficacia    e Es posible que escuche un clic proveniente del termostato cuando el compresor comienza o termina un  ciclo      El agua puede acumularse en el panel de la base en condiciones de mucha humedad o en dias de lluvia   El agua puede rebasar y gotear desde la parte exterior de la unidad    e El ventilador puede continuar funcionando incluso cuando el compresor se detenga     Soluci  n de pre                E No hay alimentaci  n e Compruebe el voltaje en la salida  Correcto si es  inexistente   E Cable de alimentaci  n e Compruebe el voltaje en el interruptor giratorio  Si e    inexistente  compruebe el cable de alimentaci  n  Cambie  el cable si el circuito est   abierto    E Interruptor giratorio e Compruebe la continuidad del interruptor  Consulte el  diagrama del cableado para la identificaci  n de los  terminales  Cambie el interruptor si es defectuoso     M Cable desconectado o   Conecte el cable  Consulte el diagrama del cableado     El motor del conexi  n suelta para la identificaci  n de los terminales  con onexiones    ventilador no sueltas  Repare o cambie el terminal suelto    funciona  E Condensador  descargue    Condensador de prueba   el condensador antes de C  mbielo si no est   dentro 
53. ods  or acts of God    5  Damages caused by leaky or broken water pipes  frozen water pipes  restricted drain lines  or  inadequate or interrupted water supply    6  Damages cause by inadequate supply of air     7  Damages resulting from running the product in a corrosive atmosphere   8  Repairs when your LG product is used in other than normal  single family household use or contrary to  the instructions outlined in the product owner s manual     9  Damage resulting from accident  misuse  abuse  or improper installation  repair  or maintenance   Improper repair includes use of parts not approved or specified by LG    10  Normal maintenance as described in the installation instructions and use and care manual  such as  replacing filters  cleaning of coils  etc     11  Use of accessories or components that are not compatible with this product    12  Products with altered or removed serial numbers    13  Changes in the appearance of the product that do not affect product performance    14  Increases in utility costs and additional utility expenses    The cost of repair or replacement under these excluded circumstances shall be borne by the consumer     P No  3828A20308J Printed in Korea    
54. ot  grounding  wall power outlet to minimize the  hazard of electric shock  The customer should have  the wall receptacle and circuit checked by a qualified  electrician to make sure the receptacle is properly  grounded     DO NOT CUT OR REMOVE THE THIRD  GROUND   PRONG FROM THE POWER PLUG     A  SITUATIONS WHEN THE APPLIANCE WILL BE  DISCONNECTED OCCASIONALLY    Because of potential safety hazards  we strongly  discourage the use of an adapter plug  However  if you  wish to use an adapter  a TEMPORARY  CONNECTION may be made  Use UL listed adapter   available from most local hardware stores    The large slot in the adapter must be aligned with the  large slot in the receptacle to assure a proper polarity  connection     10 Room Air Conditioner    A CAUTION    Attaching the adapter ground terminal to the wall  receptacle cover screw does not ground the  appliance unless the cover screw is metal  and not  insulated  and the wall receptacle is grounded  through the house wiring  The customer should have  the circuit checked by a qualified electrician to make  sure the receptacle is properly grounded     Disconnect the power cord from the adapter  using  one hand on each  Otherwise  the adapter ground  terminal might break  DO NOT USE the appliance with  a broken adapter plug     B  SITUATIONS WHEN THE APPLIANCE WILL BE  DISCONNECTED OFTEN    Do not use an adapter plug in these situations   Unplugging the power cord frequently can lead to an  eventual breakage of the ground term
55. ough the modes from COOL  gt  FAN  tics     TEMPERATURE SETTING    COOL   Use this button to automatically control the     Fan runs continually for normal cooling operation  temperature of the room     ENERGY SAVER The temperature can be set within a range of    54   F to 86   F by increments of 2   F     The fan stops when the compressor stops cooling    The setting appears in the display   Approximately every 3 minutes the fan will turn on and the unit  will check the room air temperature to determine if cooling is  needed     FAN     Fan operation without heating or cooling     HEAT    Fan runs continually for normal heating operation   TIMER    SHUT OFF TIME    e You will usually use shut off time while you sleep    e If unit is running  use Timer to set number of hours until shut off      For your sleeping comfort  once Time is set  the Temperature setting will raise 2   F after 30 minutes  and once again  after another 30 minutes    e Push Timer to cycle through the settings from 1 Hour  gt  2 Hours  gt       gt  12 Hours maximum     14 Room Air Conditioner       Control Locations       FUNCTION     If the unit has a malfunction  a green OPERATIONLED located on the Display PCB used by the unit to  indicate the errors     USE     If the customer has to register a complaint to the service center  he can be very clear about registering  the complaint that what is happening  amp  by referring the user s manual the customer can clearly define  the problem    So that the engi
56. podr  a    resultar da  ado     Este dispositivo contiene productos qu  micos  incluyendo  plomo  conocido en el estado de California como producto  cancer  geno y causante de defectos de nacimiento y otros  da  os al sistema reproductor  L  vese bien las manos tras  manipular el dispositivo  No desmonte  modifique ni sumerja    en agua este enchufe     Si el dispositivo se activara  deber   corregir la causa antes    de volver a utilizarlo       PRECAUCION    Los hilos conductores dentro del cable est  n rodeados por  blindajes  que supervisan la corriente de fuga  Estos blindajes    no est  n puestos a tierra    lt Fabricado en Tower gt     Examine peri  dicamente el cable en busca de cualquier da  o   No utilice este producto si los blindajes resultaran expuestos   Evite el riesgo de descargas el  ctricas  esta unidad no puede  ser reparada por el usuario por ser resistente y a prueba de  alteraciones  Manipular la porci  n sellada de la unidad anular    todas las garant  as y quejas de rendimiento  Esta unidad no est    dise  ada para su uso como un interruptor de encendido     apagado       Si la unidad est   equipada con cables y enchufes   siempre que est  n instalados con sub bases  y el cable y  el enchufe est  n incluidos en el interior de la sub base      La sub base debe contar con medios para garantizar una    conexi  n permanente       La sub base debe contar con una toma para la conexi  n    del cable y el enchufe     e Para completar la instalaci  n de este PT
57. ra el montaje del nuevo aparato de  aire acondicionado deben estar en un estado estructural  adecuado y disponer de la rejilla posterior que se fija de   F   z    formia mee ae    f la I del Dimensiones del montaje del manguito  opcional   manguito para sujetar el nuevo aparato de aire  acondicionado          Para evitar vibraciones y ruido  aseg  rese de que la  unidad est   instalada de forma segura y firme     Cuando instale el manguito  aseg  rese de que no hay  ning  n obst  culo en una distancia de 50 cm desde la  parte posterior que pudiese interferir en la radiaci  n de  calor y el flujo de aire de extracci  n        349 1 4m  1413 3 4      VEA Para mantener el mejor               funcionamiento de LG PTAC  AISLAMIENTO ALOJAMIENT   fije una banda de aera aoo aren  aislamiento  La banda de DE CALOR  aislamiento INTAKE se ENTRADA   gt       DE AIRE  incluye en la caja  Consulte el dnd  diagrama de abajo nivel de 1 44  M  s de 20   1  Extraiga la banda de aislamiento del embalaje  superior  280 mm     11   Parte frontal Banda aislante       2  Fije la banda de aislamiento sobre el lado superior de  la parte posterior del manguito de pared        3  Si desea mejorar la eficacia de la energia de la  unidad  es recomendable que cambie la rejilla  exterior por una protecci  n de la unidad y una rejilla  posterior de pl  stico adicional   Opcional  Posterior          Manual del propietario 35    Instalaci  n      INSTALACI  N DE LA UNIDAD    1  Quite el tornillo de embalaje d
58. s  Si es flojo  repare o  substituya     e Compruebe si existe alguna restricci  n en el sistema        Refrigeraci  n o  calefacci  n  insuficientes    E Filtro de aire  E Puerta del regulador del  tubo de expulsi  n    e Si es as    l  mpielo o c  mbielo     e Ci  rrelo si est   abierto        Ruido excesivo    E Unidad m  s peque  a de  lo normal    E Ventilador de flujo    transversal    E Tubos de cobre    e Determine si el tama  o de la unidad es el adecuado  para el   rea a refrigerar    e Revise el tornillo o la abrazadera  Si est  n sueltos o  faltan  corr  jalo  Si el ventilador de impulsi  n o el  ventilador golpean la gu  a de aire  vuelva a colocar las  piezas de manipulaci  n del aire     e Vuelva a colocar los tubos con cuidado de modo que    no entren en contacto con el compresor  la cubierta y  la barrera        L  MITES DE VOLTAJE DEL APARATO DE AIRE ACONDICIONADO             POTENCIA NOMINAL DE LA i    PLACA DE IDENTIFICACI  N MINIMA  MAXIMA  208 230 V 187 V 253 V  265 V 238 V 292 V                Manual del propietario 49    Nota    50 Aparato de aire acondicionado    LG ELECTRONICS  INC     LG Packaged Terminal Air Conditioner Limited Warranty   USA       Should your LG Packaged Terminal Air Conditioner prove to be defective in materials or workmanship under normal use during  the warranty period listed below  LG Electronics will replace the defective part s   Replacement part s  will meet intended fit and  unction of the original part s   Replacement par
59. stico para mantenerlo seco     Las unidades resistentes a la corrosi  n que funcionan en condiciones atmosf  ricas adversas deben  quitarse del manguito y limpiarse cada 3 meses siguiendo el procedimiento descrito arriba     Compresor   N       El compresor y el motor del ventilador est  n sellados herm  ticamente  lubricados de forma  permanente y no requieren engrase adicional        Parte frontal d       Limpie la parte frontal del armario y la rejilla de aire de descarga con jab  n o detergente suaves  No  utilice agentes de limpieza con base de hidrocarburo en ninguna circunstancia  p ej   acetona   benceno  naftalina  gasolina  etc   para limpiar las rejillas delanteras ni de aire     Limpie la zona de controles con cuidado  No utilice un pa  o de limpieza excesivamente h  medo        Los modelos resistentes a la corrosi  n que se encuentran en ambientes de costa da  inos para ellos  deben quitarse del manguito de pared y limpiarse completamente con agua limpia al menos cuatro  veces al a  o  El panel de base  la divisi  n central  las placas finales del condensador y el  condensador deben rociarse con spray de agua limpia y fresca  Dejar la unidad en el manguito y  simplemente rociar la rejilla exterior con spray no es suficiente     46 Aparato de aire acondicionado    Mantenimiento y asistencia t  cnica       Los consejos para la resoluci  n de problemas permiten ahorrar tiempo y dinero   Revise la siguiente tabla antes de llamar al servicio t  cnico     Funcionamient
60. tro de  ventilaci  n tal y como se muestra en la Ilustraci  n A     4  Extraiga el filtro de ventilaci  n desatornillando los dos  tornillos situados en la parte superior del filtro y  presion  ndolo ligeramente desde el panel divisor   Consulte la Ilustraci  n B     5  Limpie y cambie el filtro volviendo a fijar el gancho en la  parte inferior de la puerta de ventilaci  n y cambiando los  dos tornillos  deslice el armaz  n de nuevo hacia el  interior del manguito de pared  f  jelo con seis tornillos y  vuelva a instalar la caja frontal        Ilustraci  n A      Ventilaci  n  Left side of unit      lt         llustraci6n B      Extracci  n del filtro de ventilaci  n       Manual del propietario 45    Mantenimiento y asistencia t  cnica        La bandeja base puede desbordarse debido a  un alto nivel de humedad    Retire el tap  n del conducto de drenaje en la  parte posterior de la unidad para drenar el  exceso de agua        Limpie el armaz  n cada cuatro meses o con mayor frecuencia seg  n las condiciones atmosf  ricas   Utilice agua y detergente para limpiar la bandeja base  la divisi  n central y las bobinas  El uso de  materiales de limpieza agresivos podr  a causar un deterioro de las aletas o en las placas tubulares  de la bobina  No utilice un limpiador de alta presi  n  ya que podr  a causar da  os graves en las aletas  y las bobinas de PTAC  Puede utilizar una manguera para limpiar las bobinas  pero aseg  rese de  cubrir el control con una manta o una bolsa de pl  
61. ts are warranted for the unexpired portion of the original warranty period  This  warranty is good only to the original purchaser of the product and effective only when used in the United States     WARRANTY PERIOD   For The Period Of    LGE Will Replace                 One Year Any part of LGE Packaged Terminal which fails due to a defect in materials or workmanship  During this   From the date of the   full one year warranty  LGE will also provide  free of charge  all labor and on site service to replace   original purchase the defective part    Five Years Any part of the sealed refrigerating system  the compressor  condenser  evaporator and all   From the date of the   connecting tubing  which fails due to a defect in materials or workmanship  During this full five year   original purchase sealed refrigerating system warranty  LGE will also provide  free of charge  all labor and on site  service to replace the defective part    Five Years For the second through the fifth year from the date of original purchase  LGE will replace certain   From the date of the   parts that fail due to a defect in materials or workmanship  Parts covered are fan motors  switches    original purchase thermostats  heater  heater protectors  compressor overload  solenoids  circuit boards  auxiliary controls        thermistors  frost controls  ICR pump  capacitors  varistors and indoor blower bearing  During this limited  four year parts warranty  you will be responsible for any labor or on site s
62. uridad           27    Antes de poner el equipo en    funcionamiento    31  Introducci  n    32  Seguraida Electrica                        33  Instalacion     0 0  0  eee 35  Ubicaci  n de los controles            37    Mantenimiento y asistencia  oros 45       26 Aparato de aire acondicionado     f PARA SUS ARCHIVOS    Escriba aqu   el modelo y n  mero de serie    Modelo n      Serie n      Puede encontrar estos datos en la etiqueta situada en el  lateral de cada unidad     Nombre del distribuidor   Fecha de compra     E Adjunte su recibo a esta p  gina con la grapadora para el  momento que lo necesite para probar la fecha de su  adquisici  n o para la validaci  n de la garant  a     LEA ESTE MANUAL    En su interior encontrar   muchos consejos   tiles sobre la  utilizaci  n y mantenimiento de su acondicionador de aire   Unos pocos cuidados por su parte le pueden ahorrar  mucho tiempo y dinero durante la vida de su  acondicionador de aire    En la tabla de consejos para la soluci  n r  pida de  problemas encontrar   muchas respuestas a los problemas  m  s habituales  Si revisa primero nuestra Tabla de  Consejos para la soluci  n r  pida de problemas  tal vez no  necesite llamar nunca al servicio t  cnico     PRECAUCI  N       P  ngase en contacto con un t  cnico del servicio  autorizado para realizar la reparaci  n y  mantenimiento de esta unidad      P  ngase en contacto con un instalador para realizar  la instalaci  n de esta unidad      Cuando se va a cambiar el cable el
63. y in the room  set the  ventilation lever to the OPEN position    The damper is opened and outdoor air is drawn   into the room    This will reduce the cooling or heating efficiency     A CAUTION    When the air conditioner has been running and is  turned off or set to the fan position  wait at least 3  minutes before resetting to the cooling operation     Note  A slight heat odor may come from the unit  when first switching to HEAT after the  cooling season is over    This odor  caused by fine dust particles on  the heater  will disappear quickly   This is harmless     OPERATION    Control Locations    OPERATION MODE SELECTOR    OFF   LOW FAN  HIGH FAN  LOW COOL  HIGH COOL    LOW HEAT  HIGH HEAT    Turns air conditioner off    Low speed fan operation without cooling   High speed fan operation without cooling   Cooling with the low speed fan operation     Cooling with the high speed fan  operation     Heating with the low speed fan operation     Heating with the high speed fan  operation        Owner s Manual 13    Control Locations        Electronic Co    The controls will look like one of the following     FAN SPEED    Every time you push this button  it cycles through the settings as follows    High F2   gt  Low F1   gt  High F2   gt  Low F1           POWER               e To turn the air conditioner ON  push this button   GM To turn the air conditioner OFF  push the button  again   e This button takes priority over any other button    MODE    Push this button to cycle thr
    