1. Gen CORPORATION Installation and Operating Instructions GENERATOR SAFETY TRANSFER SWITCH MODELS 15116V 30116V 20216V 30216V 30310V Thank you for purchasing a Gen Tran Manual Transfer Switch designed to safely connect a portable generator to the load center in your home or business single phase only for standby power applications Product features include e Pre wired for fast easy connection to the load center e position switches for transferring circuits from utility to generator power e Dual wat meters are provided to help you monitor and balance the loads on your generator prolonging generator life e Power Inlet for quick cord connection to your generator e Aluminum enclosure won t rust for indoor use only e No feeder breaker needed in main load center electrical panel Warning Gen Tran transfer switches should be installed by a professional electrician familiar with electrical wiring and codes and experienced in working with generators Gen Tran accepts no responsibility for accidents damages or personal injury caused by incorrect installation These transfer switches are intended for surface mounting INDOORS only Gen Tran transfer switches are made from UL listed or recognized components and meet the Model 15116V criteria of National Electrical code Article 702 6 for Optional Standby Systems CAUTION No appliance should have an amperage rating that exceeds the individual breaker rating
2. regularly and keep the tank filled with fresh fuel Perform the following steps at least ONCE A MONTH to keep the generator properly exercised It is not necessary to turn off any circuits in the Main load center when supplying generator power with the Gen Tran transfer switch even when the utility power is operating normally The 3 position switches prevent backfeeding generator power to the utility and conversely utility power to the generator Transferring from Utility Power to Generator Power 1 Plug in the female connector of the Power Cord to the Power Inlet Box OR Gen Tran transfer switch Be sure that all switches on the transfer switch are in the UTIL or OFF position 2 Insert the male plug of the Power Cord into the outlet on the generator 3 Start the generator outdoors following the procedures described in the generator s owner s manual furnished by the manufacturer 4 Select the circuits to be powered by the generator by moving the corresponding Gen Tran switches to the GEN position Use only necessary household items when under generator power and alternate use of larger loads like furnace motors well pumps freezers etc 5 While in the GEN position each circuit is limited by the Gen Tran circuit breaker to a maximum shown on the circuit breaker If you are running a 20 amp circuit through a 15 amp breaker in the transfer switch you may have to turn off some appliances to avoid tripping this circuit breaker on the transf
3. Pelador y cortador de cable directamente a una caja de entrada de electricidad e Destornilladores incluyen Romex conector de 1 2 pulgada y 6 0 10 e Cinta de medir conectores de cable amarillo e 4 sujetadores de pared y tornillos Componentes Clave Interruptores de 3 posiciones Estos interruptores le permiten a usted seleccionar bien sea servicio p blico UTIL o generador GEN como la fuente de electricidad para los circuitos que han sido conectados a trav s del interruptor de transferencia Gen Tran La posici n de apagado OFF generalmente no se usa y un interruptor en esta posici n remover ese circuito tanto de la l nea de la electricidad de servicio p blico como del generador Disyuntores de circuito Cada circuito Gen Tran tiene un disyuntor de circuito de oprimir para reajustar que est activo cuando el Interruptor est en la posici n GEN En la posici n UTIL cada circuito est protegido por el disyuntor en centro de carga VOTA Los modelos 20216V 30216V y 30310V se entregan con disyuntores de 20 amperios en las posiciones de circuito de 2 polos C D y modelo 30310V incluye disyuntores de 20 amperios en los posiciones mas bajos Estos circuitos DEBEN estar conectados a circuitos de 20 amperios en el panel de la casa Medidores de vatios Indican las cargas en vatios cuando el generador est suministrando electricidad El medidor de la izquierda mide la carga en los circuitos A B C y el medidor derecho mide l
4. Se suministran medidores dobles de vatios para ayudarle a usted a monitorear y equilibrar las cargas en su generador prolongando as la vida til del mismo e Entrada el ctrica para una r pida conexi n de cable a su generador e Acabado durable e Nose necesita disyuntor de alimentaci n en el centro principal de carga panel el ctrico Advertencia Los interruptores de transferencia Gen Tran deben ser instalados por un electricista profesional familiarizado con el cableado y los c digos el ctricos y con experiencia de trabajo con generadores Gen Tran no se hace responsable por accidentes da os o lesi n personal causada por instalaciones incorrectas Estos Interruptores de transferencia son dise ados para ser montados sobre una superficie solamente en INTERIORES Los interruptores de transferencia GenTran est n fabricados con componentes listados o reconocidos por UL Underwriting Laboratories y cumplen con los criterios del Art culo 702 6 del C digo El ctrico Nacional para los Sistemas Opcionales de Reserva PRECAUCI N Ning n electrodom stico debe tener una clasificaci n de amperaje que exceda la tasa del disyuntor el ctrico individual del interruptor de transferencia El amperaje total de todos los circuitos puede exceder la tasa del generador pero no todos los circuitos podr n ser usados concurrentemente No conecte electrodom stico alguno que sea tasado a m s de 15 amperios Modelo 15116V 20 amperios Model
5. apagar selectivamente otros electrodom sticos en tal circuito para no exceder la capacidad del disyuntor de circuito Gen Tran Pruebe los circuitos usando medidores de vatios o determine la potencia en vatios seg n lo que muestra cada electrodom stico Tome nota de cualquier carga excesiva que deba ser retirada de un circuito espec fico durante la operaci n del generador Transferencia de electricidad de Generador a electricidad de servicio p blico 1 Regrese todos los interruptores Gen Tran A B C D etc a la posici n de UTIL 2 Siga los procedimientos indicados en el manual del due o del generador para apagar el mismo 3 Desenchufe el cable el ctrico del generador y luego la entrada de electricidad 4 Permita que el generador se enfr e y almac nelo en un lugar seco y asegurado Gen Tran Corporation Llamada sin cargo 1 888 GEN TRAN Fax 770 552 7756 www gen tran com 2006 Gen Tran Corporation Todos los derechos est n reservados Gen Tran y PowerStay son marcas comerciales registradas de Gen Tran Corporation 11 10 06 PN 50360 Rev D
6. cutter e Other supplies needed if hardwiring to a Power Inlet e Screw drivers Box include Romex 12 connector and wire e Tape measure connectors e Z4wallanchors and screws Key Components 3 Position Switches These switches allow you to select either utility UTIL or generator GEN as the power source for the circuits that have been wired through the Gen Tran transfer switch The OFF position is not generally used and a switch in this position will remove that circuit from both the utility line and generator power Circuit Breakers Each Gen Tran circuit has a push to reset circuit breaker that is active when the Switch is in the GEN position In the UTIL position each circuit is protected by the breaker in the load center VOTE Models 30116V 20216 and 30216 are shipped with 20 amp breakers in the 2 pole circuit positions C D and model 30310V Is shipped with 20 amp breakers in the bottom four positions D E and J These circuits MUST be connected to 20 amp circuits in the house panel Wattmeters Indicate the circuit loads in watts when the generator is supplying power The left meter measures the load on circuits on the left side A B C and the right meter measures the load on right circuits DEF NOTE If you are using a generator that produces 120 volts only the combined wattage readings on both A and B meters added together must not exceed the continuous wattage rating of the generator Handle Tie s F
7. a Corte y pele 5 8 de pulgada Inserte los cables Rojos en el disyuntor y apriete Los cables Azules se conectan de la misma manera que se indica arriba 6 Si usted no tiene circuitos de 240 voltios en su centro de carga no se necesita n el los circuito s de la atadura de manejo Gire el los interruptor es de la atadura de manejo a la posici n GEN Afloje los dos tornillos de la atadura de manejo retire la atadura de manejo y des chela Estos circuitos ahora pueden ser usados como circuitos de 1 polo seg n usted los seleccione 7 Una vez que usted ha cableado todos los circuitos en el interruptor Gen Tran s lo quedan el cable Blanco neutro y el cable Verde a tierra Inserte el cable Blanco neutro dentro de un orificio inutilizado en la barra neutra del centro de carga y apriete Luego inserte el cable Verde a tierra dentro de un orificio inutilizado en la barra de tierra de haberla y apriete Si no existe barra de tierra inserte el cable Verde dentro de un orificio inutilizado en la barra neutra y apriete 8 Reemplace la cubierta del centro de carga Complete la tabla en la parte superior del interruptor de transferencia Gen Tran para describir sus circuitos de emergencia y n meros relativos de circuito en el centro de carga ENCIENDA todos los disyuntores en el centro de carga y encienda todos los interruptores de transferencia hacia la posici n de UTIL La instalaci n ha sido completada Nota sobre Conexiones Permanentes Estos i
8. a carga en los circuitos D E F NOTA Si usted est usando un generador que produce solamente 120 voltios las lecturas combinadas de vatios en los medidores A y B sumados no debe exceder la tasa continua de vatios del generador Barra de uni n Para usos de 2 polos 240 voltios En los modelos de 6 circuitos debe ser usada S LO en circuitos C D Puede usar combinaciones hasta 5 en modelo 30310V Los modelos 15116V y 30116V pueden conectarse permanentemente para uso con aplicaciones de 120 240 voltios Puede ordenar barras de union a 1 888 GEN TRAN Entrada el ctrica Para una conexi n de cable r pida y f cil Planificando la instalaci n del interruptor de transferencia 1 Determine los electrodom sticos circuitos o equipo que usted desea operar con energ a del generador durante una interrupci n de la energ a tales como e Refrigerador congelador e Abridor de puerta de garaje e Bomba de sumidero e Soplador de calorifero s lo e Microondas m quina e Computadora fax e gas aceite cafetera impresora e Televisor radio e Bomba de pozo e Tel fono inal mbrico e Luces e Sistema de seguridad 2 Determine los amperios requeridos para cada electrodom stico leyendo la etiqueta del electrodom stico 3 Asigne el n mero de circuito en el centro de carga y en el interruptor de transferencia Gen Tran haciendo coincidir el tama o del disyuntor de circuito en el centro de carga al disyuntor de circuito en el interrup
9. ctor Twist on see Wi d both wires into yello e co Gon than conn ire tightly push wires back into side of box a A dor rre fi z To Well Pump 240 volt circuit To Furnace or other 120 Volt Circuit Neutral Bar 00000000000000000 BEBEN Wire Connectors White N Sii A 666 N BIB BIBS NS Ground Bar 5000000000 Red Red Red Blue Blue White 5 A handle tie is installed on the 240 volt circuit s on some models Locate the Red and Blue wires for the circuits with the handle tie Turn off the 2 pole H breaker in the load center and remove wires as ESOS gt TNS above Feed wires from handle tied switch es to the 2 pole breaker as above Cut and strip 5 8 Insert red wires in breaker and tighten Blue wires connected as above 6 If you have no 240 volt circuits in your load center the handle tie s are not needed Turn the handle tied switch es to the GEN position Loosen the two screws on the handle tie remove the handle tie and discard These circuits can now be used as 1 pole circuits as you select 7 Once you have wired all circuits in the Gen Tran switch only the White neutral wire and Green ground wire remain Insert the White neutral wire into an unused hole in the neutral bar
10. ectricidad del generador con el interruptor de transferencia Gen Tran aun cuando la electricidad del servicio p blico est operando normalmente Los interruptores de 3 posiciones evitan que se retroalimente electricidad del generador al servicio p blico y rec procamente electricidad del servicio p blico al generador Transferencia de electricidad de servicio p blico a electricidad de generador 1 Enchufe el conector hembra del cable de electricidad a la caja de entrada el ctrica O al interruptor de transferencia Gen Tran Aseg rese que todos los interruptores del interruptor de transferencia est n en la posici n de UTIL o APAGADO 2 Inserte el conector macho del cable de electricidad dentro de la salida del generador 3 Encienda el generador en exteriores siguiendo los procedimientos descritos en el manual del propietario del generador provisto por el fabricante 4 Seleccione los circuitos que han de ser activados por el generador moviendo los interruptores Gen Tran correspondientes a la posici n GEN Use solamente los electrodom sticos necesarios cuando est bajo electricidad del generador y alterne el uso de cargas mayores tales como motores de calorifero bombas de pozo congeladores etc 5 Mientras est n en la posici n GEN cada circuito est limitado por el disyuntor de circuito Gen Tran a un m ximo que se muestra en el disyuntor de circuito Si usted ha seleccionado un circuito que hala m s que esto ser necesario
11. er switch Test your circuits by using the wattmeters or determine wattage from that shown on each appliance Make a note of any excessive loads which must be removed from a given circuit during generator Operation Transferring from Generator Power to Utility Power 1 Return all Gen Tran switches A B C etc to the UTIL position 2 Follow the procedures in the generator s owner s manual to shut down the generator 3 Unplug the power cord from the generator and then the power inlet 4 Allow generator to cool off and store in a dry secured location Gen CORPORATION s Toll Free 1 888 GEN TRAN Fax 770 552 7756 www gen tran com 2006 Gen Tran Corporation All Rights Reserved Gen Tran and PowerStay are registered trademarks of Gen Tran Corporation 11 10 06 PN 50360 Rev D 4 Geny Tran Instrucciones de Instalaci n y Operaci n INTERRUPTOR DE TRANSFERENCIA DE SEGURIDAD DE LOS MODELOS 15116V 30116V 20216V 30216V 30310V DE GENERADOR Gracias por adquirir un Interruptor de Transferencia Manual GenTran dise ado para conectar con seguridad un generador port til al centro de carga en su casa o negocio solo de fase sencilla para aplicaciones de electricidad de reserva Las caracter sticas del producto incluyen e Previamente cableado para una conexi n r pida y facil al centro de carga e Interruptores de 3 posiciones para transferir circuitos del servicio p blico de electricidad al generador e
12. er switch to wall using the external feet Do not overbend flexible conduit Aan TTT NESA i Mi lt Approx 18 gt Rod a 3 a D e To Furnace or other 120 Volt Circuit HARDWIRED BASEMENT INSTALLATION TYPICAL GARAGE INSTALLATION Power Inlet Box 25 ft Power Cord i Mg E a al a E J Wiring your Gen Tran_ Transfer Switch to the Load Center IMPORTANT Please read this entire procedure before beginning installation WARNING For SAFETY turn OFF the MAIN circuit breaker in the load center BEFORE starting installation Remember the wiring ahead of the MAIN is HOT even when the main circuit breaker is off 1 After determining which circuits you will want to use during an emergency we suggest you start wiring the most critical circuits first starting with A 2 Assuming you want to designate your Furnace as A turn the Furnace circuit breaker OFF and loosen the screw which secures this wire into the circuit breaker and remove wire 3 On the Gen Tran transfer switch find the Blue and Red wires marked A Feed these two wires to the selected breaker Furnace Cut Red wire A toa convenient length strip approximately 5 8 install in circuit breaker and retighten screw Take Blue lead A cut to convenient length to match up with wire 9000000 removed from circuit breaker Strip 5 8 and insert h wires in Ilow wire conne
13. ga el interruptor de transferencia Gen Tran sobre la pared a unas 18 pulgadas del centro del panel el ctrico para asegurar espacio adecuado Retire la cubierta del centro de carga PRECAUCI N 7odos los cables est n activos dentro del centro de carga Los disyuntores de circuito PRINCIPALES deben apagarse para garantizar la seguridad Recuerde todos los cables del lado l nea de la conexi n principal a n est n activos 6 Localice y remueva un separador en la base del panel el ctrico cerca del centro si fuera posible Use un separador de 3 4 de pulgada para todos los modelos Inserte todos los cables del interruptor de transferencia Gen Tran al final del conducto flexible hasta el separador e instale el conector de manera segura 7 Sujete el interruptor de transferencia a la pared usando las patas externas No doble demasiado el conducto flexible U1 INSTALACION DE CONEXION PERMANENTE EN UN SOTANO INSTALACION TIPICA EN UN GARAJE Entrada el ctrica Cable el ctrico de 10 pies 4 A Instalacion de cableado del interruptor de transferencia Gen Tran al centro de carga IMPORTANTE Por favor lea la totalidad de este procedimiento antes de comenzar la instalaci n ADVERTENCIA Por SEGURIDAD APAGUE el disyuntor PRINCIPAL de circuito del centro de carga ANTES de comenzar la instalaci n Recuerde el cableado por delante del PRINCIPAL est ACTIVO a n cuando el disyuntor principal de circuito est apagad
14. in the load center and tighten Then insert the Green ground wire into an unused hole in the ground bar if existing and tighten If no ground bar exists insert the Green wire into an unused hole in the neutral bar and tighten O To Ground Rod 8 Replace the cover to the load center Fill in the chart on the top of the Gen Tran transfer switch to describe your emergency circuits and related circuit numbers in the load center Turn ON all breakers in the load center and turn all switches on the transfer switch to the UTIL position Installation is now complete Note on Hardwiring These transfer switches may be hardwired to a power inlet box located remotely from the Gen Tran transfer switch If you are hardwiring the transfer switch to a remote power inlet box remove the flanged power inlet from the face of the transfer switch and install the closing plate provided to cover the hole See the specification chart on page 1 for Power Inlet Box models Wires inside the transfer switch should be connected to the Power Inlet Box as follows Gen Tran Black wire To Power Inlet X or Y terminal Gen Tran White wire To Power Inlet Neutral W terminal Gen Tran Red wire To Power Inlet X or Y terminal Gen Tran Green wire To Power Inlet Ground G terminal Using your Gen Tran Transfer Switch To ensure that your generator will always be ready when you need it it is important to start and run your generator UNDER LOAD
15. in the transfer switch The total amperage of all circuits can exceed the generator rating but not all circuits will be able to be used concurrently Do not connect any appliance that is rated at more than 15 amps Model 15116V or 20 amps Models 30116V 20216V 30216V 30310V Gen Tran is not responsible for accidents or property damage due to incorrect or inappropriate installation Model 15116V 30116V 20216V 30216V 30310V Circuits Provided CTE amos 4 15 amps 4 15 amps 4 15 amps 6 15 amps P 2 20 amps 2 20 amps 2 20 amps 4 20 amps Max GEN Watts 1875 3750 5000 7500 7500 Max GEN Amps 15 Amps 120 30 Amps 120 volts volts P 3 20 Amps 120 240 30 Amps 120 240 30 Amps 120 240 Can be hardwired Can be hardwired for volts volts volts for 120 240 volts ee 120 Volts F120 Volts 120 240 Volts 120 240 Volts 120 240 Volts of 2 pole circuits es NK Only if hardwired and used with a generator 1 1 5 that produces 120 240 volts NEMA Type Enclosure 1 Indoor Only 1 Indoor Only 1 Indoor Only 1 Indoor Only 1 Indoor Only NEMA Configuration of 5 15 15 30 114 20 114 30 114 30 Male Inlet Compatible Power Inlet Box Power Cord Wire Gauge 12 gauge 3 wire 10 gauge 3 wire 12 gauge 4 wire 10 gauge 4 wire 10 gauge 4 wire NA 53002 or 530V 14202 or 1420V 14302 or 1430V 14302 or 1430V Tools Needed for Installation e Power Drill e 6or10 wire connectors yellow size e Wire Stripper and
16. lation diagrams below In addition to the transfer switch you may need additional accessories to complete your transfer switch installation such as a generator cord and power inlet box A generator cord sold separately is needed to connect your generator to the Gen Tran transfer switch or power inlet box If your load center is in your garage we recommend at least a 25 foot generator cord to reach from your generator outside the garage on the driveway to the transfer switch NEVER run a generator in an enclosed area If your load center is in a basement or interior room you should install a power inlet box sold separately on the exterior of your house or building to avoid running the generator cord through a door or window 5 Transfer switch can be installed on either the left or right side of your electrical panel also called load center Hold the Gen Tran transfer switch up to the wall about 18 from the center of the load center to ensure adequate room Remove the cover of the F load center CAUTION A wires are live inside load center EE Q EELE il MAIN circuit breakers should be turned off to ensure safety BAED Remember all wires on line side of main are still hot 6 Locate and remove a knockout KO in the bottom of the load center near the center if possible Use 3 4 KO for all models Insert all wires from Gen Tran transfer switch at end of flexible conduit through KO and install connector securely 7 Anchor transf
17. nterruptores de transferencia pueden conectarse de manera permanente a una caja de entrada de electricidad localizada lejos del interruptor de transferencia Gen Tran Si usted est conectando de manera permanente el interruptor de transferencia a una caja lejana de entrada de electricidad retire la entrada de electricidad rebordeada de la fachada del interruptor de transferencia e instale la placa de cierre suministrada para cubrir el agujero Vea la tabla de especificaciones en la p gina 1 para los modelos de Caja de Entrada de Electricidad Los cables dentro del interruptor de transferencia deben ser conectados a la Caja de Entrada de Electricidad como sigue debajo e Cable Negro Gen Tran A la Entrada de Electricidad del terminal X or Y e Cable Blanco Gen Tran A la Entrada Neutral de Electricidad del terminal W e Cable Rojo Gen Tran A la Entrada de Electricidad del terminal X or Y e Cable Verde Gen Tran A la Entrada de Electricidad a Tierra del terminal G Uso del interruptor de transferencia Gen Tran Para asegurar que su generador siempre estar listo cuando lo necesite es importante encender y hacer funcionar su generador BAJO CARGA UNDER LOAD regularmente y mantener el tanque lleno con combustible fresco Lleve a cabo los siguientes pasos por lo menos UNA VEZ AL MES para mantener el generador apropiadamente ejercitado No es necesario apagar circuito alguno en el centro de carga Principal cuando se suministre el
18. o 1 Despu s de determinar cu les son los circuitos que querr usar durante una emergencia sugerimos que empiece a alambrar los circuitos m s cr ticos primero comenzando por A 2 Asumiendo que usted desea designar su Calorifero como A APAGUE el disyuntor de circuito del calor fero y afloje el tornillo que asegura este cable al disyuntor de circuito y retire el cable 3 En el interruptor de transferencia Gen Tran encuentre los cables Azul y Rojo marcados A Alimente estos dos cables al disyuntor seleccionado Calor fero Corte el cable Rojo A a una longitud conveniente pele aproximadamente 5 8 de pulgada inst lelo en el disyuntor de circuito y vuelva a apretar el tornillo Tome la punta del cable Azul A y corte a una longitud conveniente para emparejar con el cable retirado del disyuntor de circuito Pele 5 8 de pulgada e inserte ambos cables dentro del conector de cable amarillo Entrelace fuertemente empuje de regreso los cables dentro del lado de la caja 4 Repita los pasos 2 y 3 de arriba para alambrar los circuitos restantes Algunos modelos tienen la atadura de manejo en el los circuito s de 240 voltios Localice los cables Rojo y Azul para los circuitos con la atadura de manejo Apague el disyuntor de 2 polos en el centro de carga y retire los cables igual que se explica arriba Alimente los cables a partir del de los interruptor es de la atadura de manejo al disyuntor de 2 polos como se indica arrib
19. or 2 pole 240 volt applications On 6 circuit models the handle tie must be used on C D circuits ONLY On 10 circuit model 30310V two handle ties are included for use with two 2 pole circuits D and E J however you can wire up to five 2 pole circuits with additional handle ties Models 15116V and 30116V can be hardwired for use with 120 240 volt applications Handle ties can be ordered by calling 1 888 GEN TRAN Power Inlet For fast easy cord connection Planning Your Transfer Switch Installation 1 Determine the appliances circuits or equipment you want to operate with generator power during a power outage such as e _ Refrigerator Freezer e Garage Door Opener e Sump Pump e Furnace Blower gas oil only e Microwave Coffee Maker e Computer Fax and Printer e TV Radio e Well Pump e Cordless Telephone e Lights e Security System 2 Determine the amps required for each appliance by reading the label on the appliance 3 Assign the circuit in the load center and in the Gen Tran transfer switch matching the size of the circuit breaker in the load center to the circuit breaker in the transfer switch Once you ve determined which circuits you want to connect and the appropriate amperage you will be ready to begin installing your Gen Tran transfer switch 4 The location of your load center electrical panel in your home or business will determine where the Gen Tran transfer switch needs to be installed Refer to the typical instal
20. os 30116V 20216V 30216V 30310V Gen Tran no se hace responsable por accidentes o da o a la propiedad debido a una instalaci n incorrecta o inapropiada Modelo 15116V 30116V 20216V 30216V 30310V Numero de circuitos 6 15 amperios 4 15 amperios 4 15 amperios 4 15 amperios 6 15 amperios suministrados 2 20 amperios 2 20 amperios 2 20 amperios 4 20 amperios vatios M xima generaci n de 15 amperios 120 30 amperios 120 amperios voltios voltios Puede alambrarse Puede alambrarse permanentemente para permanentemente para 120 240 voltios 120 240 voltios 120 voltios 120 voios 120 240 voltios 120 240 voltios 120 240 voltios N mero de circuitos de 2 polos S lo si A permanentemente y usado con un generador que produce 120 240 voltios Recinto de tipo NEMA i 1 Interiores 1 Interiores 1 Interiores solamente 1 Interiores solamente 1 Interiores solamente solamente solamente Configuraci n NEMA de 15 30 114 20 114 30 114 30 entrada macho Fase r Caja de entrada el ctrica 515V 530V 1420V 1430V 1430V compatible eaiiple 2 ue qe Calibre 12 3 alambres Calibre 10 3 alambres Calibre 12 4 alambres Calibre 10 4 alambres Calibre 10 4 alambres cable el ctrico Herramientas necesarias para la instalaci n 20 amperios O 120 240 30 amperios 30 amperios voltios 120 240 voltios 120 240 voltios e Taladro el ctrico e Otros suministros necesarios si se est conectando e
21. tor de transferencia Una vez que usted ha determinado cu les circuitos desea conectar y el amperaje apropiado estar listo para comenzar a instalar su interruptor de transferencia Gen Tran 4 La ubicaci n del centro de carga panel el ctrico en su casa o negocio determinar d nde necesita ser instalado el interruptor de transferencia Gen Tran Refi rase a los t picos diagramas de instalaci n de abajo Adem s del interruptor de transferencia usted podr a necesitar accesorios adicionales para completar la instalaci n del interruptor de transferencia como por ejemplo un cable de generador y una caja de entrada el ctrica Un cable de generador vendido separadamente es necesario para conectar su generador al interruptor de transferencia Gen Tran o caja de entrada el ctrica Si su centro de carga est en su garaje nosotros recomendamos un cable de generador de por lo menos 25 pies para alcanzar desde su generador saliendo del garaje por la entrada de coches hasta el interruptor de transferencia NUNCA haga funcionar un generador en un rea cerrada Si su centro de carga est en un s tano o en un cuarto interior usted debe instalar una caja de entrada el ctrica vendida separadamente en un rea exterior de su casa o edificio para evitar correr el cable del generador a trav s de una puerta o ventana El interruptor de transferencia puede ser instalado a cualquier lado del panel el ctrico tambi n denominado centro de carga Sosten