1. afitegra SNMPOS 3PH LAN CARDS REFERENCE MANUAL ENGLISH 1 Introduction There are 2 different SNMP LAN card models SNMP 05 is a LAN card compatible with all Online UPS 1KVA to 20KVA 1 phase SNMP 05 3PH is a LAN card compatible with Online 3 phases UPS models Both cards have similar functions and capabilities only difference is their external size SNMP05 3PH is larger to fit in larger SNMP slot of 3Ph UPS Main Functions a Ethernet LAN interface 10 100 for INTEGRA Online UPS by RJ45 connector b Interface for INTEGRA Temperature and Humidity Sensor Device by RJ11 connector 2 Product Description SNMP05 SNMP05 3PH RJ 11 Rs RJ 45 RJ 11 RIAS Sensor TH A Ethernet 10 100 sensor TH AE Ethernet 10 100 Ethernet Status LEDs Ethernet Status LEDs LED Description GREEN 100MB BLINKING Detected Connection OFF Not detected YELOW 10MB BLINKING Detected Connection OFF Not detected 3 Installation Step 1 Remove SNMP slot cover on UPS DIS C Voltage Lebel Sa Leo 26 a e afitegra SNMPOS 3PH LAN CARDS REFERENCE MANUAL Step 2 Insert SNMP 05 card into the slot Step 3 Plug LAN cable in Ethernet port and check if Ethernet L
2. PC apropiado El software est disponible en la secci n de descargas de nuestra web o bien puede venir en la caja del SAI UPS El software adecuado es el de la versi n PRO dise ado para comunicaci n v a red LAN Rem tase al manual de instalaci n y configuraci n del software para la correcta instalaci n y configuraci n del mismo Paso 5 Una vez instalado y configurado el software ponga en funcionamiento el software El software se puede poner en funcionamiento haciendo click con el bot n derecho del mouse sobre el icono del enchufe color naranja que se ha instalado en la bandeja de inicio Al abrirse la ventana desplegable seleccione la opci n SNMP manager Stop Monitor SNMP Manager 4 Configuration PHARE We 15 59 Software Update Open Monitor Ext Paso 6 Una vez abra la ventana del SNMP Manager seleccione la opci n de buscar SCAN y escoja la IP din mica que la red le asigne al SAI UPS que desea monitorear Fig 6 System Settings Language Help IP address UPS name Address IP address MAC address UPS name Address Note Ey 192 168 1 Output window tte ote SNMPO5 3PH LAN CARDS gt REFERENCE MANUAL Paso 7 Ponga en ejecuci n el software de monitoreo mediante el bot n derecho del mouse en el icono naranja seleccionando la opci n OPEN MONITOR User type Adm ator Monitored UPS 192 168 102230_P
3. 01 Stop Monitor SNMP Manager f Configuration UPS i ormaton L UPS mode Converter mode UPS temp 231 C Software Update Open Monitor Si la red no asigna IP de manera din mica ser necesario asignar una IP fija a la tarjeta SNMP mediante el siguiente procedimiento 1 Puede que la IP de su PC no est en el mismo rango de IP con el que viene de f brica la tarjeta SNMP Si esto sucede se sugiere cambiar el IP del PC desde donde se har la supervisi n para ajustarlo al rango de IP predeterminado en la tarjeta Por ejemplo IP 192 168 102 XX 6 192 168 1 XX Subnet Mask 255 255 255 0 Default Gate en blanco 2 Activar el software SNMP MANAGER segun paso 6 Password 12345678 3 Hacer SCAN para ver el IP dinamico de la tarjeta Fig 6 4 Seleccione ese IP y haga a adir con el bot n ADD Fig 6 5 Escriba el rango de la IP fija que desee asignar y seleccoine APLICAR APPLY 6 Abra la pesta a IP settings y active la opci n Use a Static Address 7 Escriba el IP address y la Subnet mask y Default Gateway que desea asignar a la tarjeta de forma fija 8 En este momento la tarjeta SNMP grabar la nueva IP est tica que puede ser diferente al rango de IP que actualmente tiene su PC De ser as devuelva el IP original a su PC para que pueda monitorear a la tarjeta
4. EDs on SNMP 05 card light as described in LED description table on this manual If your application includes INTEGRA SENSOR TH plug its related cable to dedicated port in SNMP 05 card LAN _ SENSOR TH At this moment all hardware connections to include your UPS to the LAN and get data from SENSOR device are ready SAI UPS LAN NETWORK WWW WAN Internal f SNMP 04 SENSOR TH a ae dfitegra SNMPO5 3PH LAN CARDS REFERENCE MANUAL Step 4 Install INTEGRA monitoring software in your PC Our software is available inside the CD bounded with SNMP 05 card but also in our web site In our web site please make sure to select the appropriate software model for LAN monitoring applications The correct software is PRO version Follow software user manual for install and configure it Step 5 Once software is properly installed run by right clicking on ORANGE PLUG icon in your PC Select SNMP Manager option on pop up window w start Stop Monitor SNMP Manager Ov Configuration Software Update Open Monitor Exit ele 15 59 Step 6 Once SNMP Manager shows main window select SCAN option and select dynamic IP assigned to your SNMP 05 card Fig 6 System Settings Language Help IP address UPS name Address Basic Info IP settings Online upgra
5. de Password management Static trap address IP address E MAC address UPS name Address O lt 192 168 1 If no dynamic IP is assigned automatically by your LAN maybe it is because your LAN configuration does not assign dynamic IP You must contact your LAN administrator to perform following instructions You must be sure firewall is not avoiding IP configuration tte ote SNMPO5 3PH LAN CARDS gt REFERENCE MANUAL How to Assign Manually IP Address to SNMP 05 1 If your PC is in a different IP range change in your PC the IP address to adjust it to the IP address range of the SNMP 05 This is the only way to see SNMP card on the LAN For example IP 192 168 102 XX or 192 168 1 XX Subnet Mask 255 255 255 0 Default Gate leave in blank 2 Run SNMP Manager according to Step 6 login with password 12345678 3 Select SCAN option to find dynamic IP configured in SNMP card Fig 6 4 Select indicated IP and select ADD option Fig 6 5 Write the IP address you need to add for the new IP and then Apply 6 Select section IP setting and mark Use a Static Address and write the new IP address you want to assign according to your LAN administrator 7 At this moment maybe your PC is not able to monitor SNMP card with new assigned IP address because it is in different IP range Stop monitoring software and return IP in your PC address to original IP address This should allo
6. net VERDE 100MB INTERMITENTE Conexi n detectada OFF No detectada AMARILLO 10MB INTERMITENTE Conexi n detectada OFF No detectada 3 Instalaci n y conexi n Paso 1 Retire la tapa de la ranura SNMP en el panel trasero del SAI UPS RS232 Us 900 OLZIJO e INTELLIGENT SLOT afitegra SNMPOS 3PH LAN CARDS REFERENCE MANUAL Paso 2 Inserte la tarjeta SNMP 05 en la ranura y fijela mediante sus tornillos Paso 3 Conecte el cable de red en el puerto Ethernet y compruebe que encienden los LEDS verde o amarillo dependiendo del tipo de red Si tiene un medidor de temperatura numedad INTEGRA modelo SENSOR TH con ctelo al puerto apropiado seg n la figura LAN SENSOR TH En este momento el hardware necesario para conectar su SAI UPS a la red y al detector de temperatura humedad est conectado SAI UPS LAN NETWORK WWW WAN Internal i SNMP 04 SENSOR TH a afitegra SNIMPO5 3PH LAN CARDS REFERENCE MANUAL Paso 4 Instale el software de supervisi n y control del SAI UPS en el
7. w your PC to detect new static address Step 7 Run monitoring software again by right clicking on orange PLUG icon and then select OPEN MONITOR option Start Mo Stop Monitor SNMP Manager Configuration wt St Bice 168 102 230_P01 Software Update Open Monitor Ext Power flow UPS info Diagram Environmental information E Bypass UP formation bh Lo UPS mode Converter mode UPS temp 231 C Dutout information Outpt voltage 2295 V Output frequency SO Hz Laad level 4 Current 024 sra 2195 V Input frequency 50 Hz Battery maton Battery voltage 41V Battery capacity 100 aegra SNIMPO5 3PH LAN CARDS REFERENCE MANUAL ESPA OL 1 Introducci n Existen dos modelos de tarjeta SNMPO5 SNMP05 Compatible con UPS Online de 1K a 20K 1 fase SNMP05 3PH Compatible con UPS Online trif sicos a partir de 20KVA Ambas tienen las mismas funciones y capacidades Su nica diferencia es que SNMP05 3PH es un poco m s grande en su tama o externo Funciones Principales a Interfaz para conectarse con redes Ethernet 10 100 mediante su puerto RJ45 y b para recibir conectar con el sensor de medici n ambiental 2 Descripci n de la tarjeta SNMP05 SNMP05 3PH RJ 11 Sensor TH RJ 45 RJ 11 Ethernet 10 100 Sensor TH RJ 45 E Ethernet 10 100 TETTED Ethernet Status LEDs Ethernet Status LEDs Estado de los LED del puerto Ether