Home
Manual de instalación y mantenimiento
Contents
1. We reserve to change all or part of the articles or continents of this document without prior notice Nous nos r servons le droit de modifier totalement oru en partie les caracteristiques de nos articles ou le contenu de ce document san pr avis Nos reservamos el derecho de cambiar total o parcialmente las caracter sticas de nuestros art culos o contenido de este documento sin previo aviso Ci reservamo el dritto di cambiare totalemente o perzialmente le ceratteristique tecniche dei nostri produtti ed li contennutto di questo documento senza nessum preawiso Wir behalten uns das recht vor die eigenschaften unserer produkte oder den inhalft dieses porspektes teilweise oder wolfstanding ohne vorheriege benachichtigung Reservamo nos no dereito de alterar total o parcialmente as caracter sticas dos nossos artigos ou o contenido deste documento sem aviso pr vio POLTANK SAU Crta de Sales s n 17853 Tortell SPAIN SEMI IN GROUND PLANT HOUSING LOCAL SEMI ENTERRE CASETA SEMIENTERRADA ALLOGGIAMENTO SEMINTERRATO FILTERBOX CASETA SEMIENTERRADA Model 00621 INSTALLATION AND MAINTENENCE MANUAL MANUEL D INSTALLATION ET D ENTRETIEN MANUAL DE INSTALACI N Y MANTENIMIENTO MANUALE DI INSTALLAZIONE E MANUTENZIONE EINBAU UND BETRIESBSANLEITUNG MANUAL DE INSTRUCOES E MANUTENCAO 1 CHARACTERISTICS Semi in ground plant housing manufactured in polyester resine fiberglass PT rr to contain filters and compac
2. Le local doit tre distant au minimum de 3 m du plan d eau respect de la norme EDF C15 100 Bruit il d pendra de la qualit de la motopompe Ne pos h siter disposer un socle caoutchouc sous la motopompe TECHNICAL CHARACTERISTICS POS RON oO 01 BR ND CODE 00621 0500 00621 0600 00621 070 00616 0101 00621 0203 00621 0202 711908000 701108025 00621 0201 711906000 712106000 00621 0204 00621 0205 04970 0401 NAME main body cover hinged lid cable gland brass nut plug washer screw hinge washer nut joint joint washer UNITS RS NN NN OO OO OO O1 aa ADVERT CIAS DE SEGURANCA A empresa pessoa encarregada da instala ao tem que avaliar a natureza das terras donde se realiza a instala ao para tomar medidas necess rias caso por quest es do terreno seja necess rio fazer alguma variacao das instrucoes inclu das no manual junto a o produto A parte das carcacas enterradas debe ultrapassar como m nimo 5 mm da superf cie do chao para evitar riscos de inundacoes Durante a temporada de inverno devem usar se materiais resistentes congelacao Manter a bomba fora de contacto com o gelo Aconselha se a desmontar junto a parte el ctrica em Seco O enchimento das terraplanagens deve ser executado de forma a que n o sejam causados estragos s tubagens e liga es el ctricas que saiem da caseta ll riempimento del terrapieno si deve fare in modo che non ostruisca i tubi e le connessioni elet
3. La parte enterrada de la caseta tiene que sobrepasar el nivel del suelo un m nimo de 5 cm para evitar as riesogs de inundacones lluvias torrenciales Durante la temporada de invierno mantener el equipo bomba material el ctrico fuera del efecto de las heladas Se aconseja desmontar la bomba y todo el equipo una vez seco El llenado de los terraplenes debe hacerse de manera que no danyen a los tubos y conexiones el ctricas que salen de la caseta Los tubos de salida entrada de agua de la piscina tienen que ser instalados a menor altura que los de la salida de la caseta En caso contrario debe instalarse una v lvula antiretorno Prevenir possibles subidas de presi n durante las operaciones de lavado i enjuague del filtro tener en cuenta que los tubos de conexi n el ctrica sean de calidad y con la secci n adecuada Ld caseta tiene que se instalada como m nimo a 3 m del plano de agua de la piscina siguiendo la normativa EDF C 15 100 Ruido depender de la calidad de la bomba Existe la posibilidad de acoplar un soporte de goma bajo la bomba para absorver las vibraciones y evitar as el posible ruido AWERTIMENTI DI SICUREZZA La ditta persona indicaricata dell installazione dovr verificare che queste istruzioni siano idonee ed in caso contrario attuare tutte le modifiche del caso affinch l installazione risulti adeguata al tipo di terreno specifico Al fine di evitare rischi di inondazione l alloggiamento
4. anteriores 150 200 mm m s por Cada lado Realizzareuno scavo avente dimensioni Superiori di 150 200 mm per lato con rispetto Alle dimensioni massime dell interrafo 1n vostro Possesso Poner en el suelo grava 4 5 mm y nivelar Dicha grava vigilando el desag e Realizzare sul fondo dello scavo uno strato di Supporto con graniglia di 4 5 mm di diametro Instalar la caseta deseada y nivelarla Conectar todas las tuber as de uni n Comprobar que funcionen correctamente Installare l alloggiamento prescelto e livellarlo Collegare tutte le tubazioni e verificare che il sistema funzioni correttamente Rellenar los 150 200 mm de alrededor de las Casetas con un hormig n muy pobre 150 kg dicho relleno tendr que ser Realizado por gravedad Riempire lo spazio tra l interrato e lo scavo con una mescola povera di cemento Il riempimento deve essere effettuato per gravit Dejar secar y su instalaci n estar Terminada Una volta secco il cemento l installazione Potr dirsi finalizzata ADVERTENCIAS DE SEGURIDAD La empresa persona encargada de la instalaci n tienes que pareciar la naturaleza del suelo i tomar las medidas necesarias para construir correctamente los teraplenos que rodearan la caseta para evitar as una presi n excesiva en la paredes de esta para realizar correctamente el drenaje de las aguas de infiltraci n lluvia riego y las posibles apariciones de acu feros y subidas de aguas subterr neas
5. debe fuoriuscire dal piano di calpestio di almeno 5 mrn In inverno adottare tutte le misure possibili per evitare il congelamento degli elementi installati all intemo dell alloggiamento Preferibilmente smontare la pompa e immagazzinaria in luogo secco ed asciutto Il iempimento del terrapieno si deve fare in modo che non ostruisca i tubi e le connessioni elettriche che escono dal pozzetto Verificare che l altezza delle tubazioni di aspirazione provenienti dalla piscina siano collocate ad un luvello inferiore ai correspondenti attachi sull alloggiamento In caso contrario prevedere un adeguato sistema di antiritorno Tenere in considerazione che potrebbero verificarsi bruschi rialzi di pressione durante le operazioni di lavaggio e risciacquo L installazione dell alloggiamento e delle parti elettriche in esso incluse debe essere effettuata nel rispetto delle Norme Vigenti EDF C 15 100 Per evitare un possibile eccessivo rumore della pompa consigliabile installare sotto la stessa un adeguato sistema di assorbimiento delle vibrazioni Portugues Deutsch MANUAL DE INSTRUCOES E MANUTENGAO DE LA CASETA SEMIENTERRADA EINBAU UND BETRIESBSANLEITUNG DER FILTERBOX if Portugues Deutsch Portugues Deutsch Portugues Deutsch Portugues Portugues Deustsch Tomar as medidas de per metro e profundidade Da parte inferior da caseta cuba enterrada e Realizar o correspondente buraco somando a Estas medida
6. ng is in working order Installez et nivellez dan unit du logement de La terre et connectez totute les cananlisations Et v riples cela tout est dans ordre qui travaille Fill in the 150 200 mm gap around the Perimeter of your in ground housing unit with Concret 150 kg more or less Remplissez dans le 150 200 mm intervalle Autour du perimetre de votre dans unit du Logement de la terre avec le c ment 150 kg plus o moins Leave to dry and your installation is now ready Permission s cher et votre installation est pr te Maintenant WARNING The installation company must estimate floor state and toke necessary actions to make embankments around the plant housing to avoid overpres sures on plant housing walls to make drain correctly from infiltration water rain irrigation and ascents of subterra neous waters The inground part of planting house must overpass a minium height of 5 cm from the floor to avoid risks by floodings strongs rains In winter time must keep equipment pump electrical feeding out of frost effects ls recomended to disassemble the pump and electrical feeding when this it s still dry The concret embankement must be made being careful about piping and electrical feeding that goes out from house holding Outlet piping from the pool must be arranged at a lower highness than house holding ones Another solution is to install a non return valve Must preview overpressures during fliter back
7. s per metro de 150 a 200 mm por Lado Nehmen Sie die Mabe von Durchmesser und Tiefe der Undterseite des H uschens und heben Sie das entsprechende Loch aus indem Sie bei der Breite auf jeder Seite zus tzlich 150 bis 200 mm addieren Incorporar no buraco uma capa de 4 5 mm de cascalho e nivelar o cascalho tendo em conta o escoamento da base da caseta Bedecken Sie den Boden des Lochs mit einer Schicht von 4 bis 5 mm Schotter ebnen Sie die Schicht gleichm big ein und bedecken Sie dabei den Wasserabflub am Boden des Pumpenh uschens Instalar a caseta desejada e nivelar ligar todas as Tubagens de uniao e verificar que funcionam Correctamente Richten Sie das Pumperh uschen zur intal lation horizontal aus schlieben Sie die Verbin dungsleitungen an und berpr fen Sie deren korrekte Funktion Reencher bem os 150 200 mm em redor da Caseta com betao 150 kg muito pobre o Enchimento dever ser realizado por gravidade F llen Sie den 150 bis 200 mm breiten Rand um den Geh userand mit Zement 150 kg von niedriggradiger Mischung auf Deixar secar o betao e sua instala ao ficar Lassen Sie Zement trocknen und damit ist die Installation bereits beendet
8. s gemacht werden sollte damit nicht danyen zu den Rohren und elektrischen Verbindungen die H tte verlassen Richten Sie das Pumpenha uschen zur Installation horizontal aus schlieBen Sie die Verbindungsleitungen an und berpr fen Sie deren korrekte Funktion Bedenken Sie daB die H he der Abflubteitungen des Schwimmbades niedreger angesetzt werden m ssen als die der Abflusse des H uschens oder daB anderenfalls ein R ckhalteventil eingebaut werden muB Kalkulieren Sie m gliche pl tzliche Drucksteigerungen wahrend der Operationen Waschen und Sp len des Filters ein Bedenken Sie daB die Bauteile der Stromversorgung von guter Qualit t und die Leitungen einen angemessenen Durchmesser besitzen sollten Das H uschen sollte einen Mindestabstand zur Wasseroberfl che des Schwimmbads von drei Metern einhalten nach der Norm EDF C 15 100 L rm Die Greduschbelastingung h ngt von der Qualit t der Pumpe ad Es besteht die M glichkeit einen Gummisockel unter der Pumpe zu installieren der Vibrationen absorbiert und so die Ger uschbel stingung verringert Espanyol Italiano MANUAL DE INSTALACI N Y MANTENIMIENTO DE LA CASETA SEMIENTERRADA MANUALE DE INSTALLAZIONE E MANUTENZIONE DEL ALLOGIAMENTO SEMIENTERRATO 1 Espa ol Italiano o Espa ol Italiano I 3 Espa ol Italiano 4 Espa ol Italiano 5 Espa ol Italiano Tomar las medidas de la caseta y realizar un Agujero en el suelo sumandole a las Medidas
9. t 750 Local semienterre en r sine de polyester F V et finissage en gel coat Concu pour contenir des filtres et compact quipe d Y 450 750 equips from Y 450 to Caseta semienterrada fabricada en polyester F V acabado de gel coat Dise ada para contener filtros y equipos compactos desde 450 hasta Y 750 Allogiamento semienterrato fabbricato in resina de polyester FV finitura in gel coat Disegnato contenere filtri e patto equipaggia da Y 450 a Y 750 Filterbox aus Polyesterharz F V Gel Coat finish Entwarf um Filter zu enthalten und Kompaktauto stattet von 2450 bis 2750 aus Caseta semienterrada em resina de polyestere F V Acabado em gel coat Projetado para conter filtros e p compacto equipa de Y 450 a 750 2 DIMENSIONS mm English Francais SEMI INGROUND PLANT HOUSING INSTALLATION MANUAL MANUEL D INSTALLATION ET D ENTRETIEN DU LOCAL SEMI ENTIERRE English Francais English Francais English Francais English Francais English Francais Having measured the in ground housing Overdig a hole by 150 200 mm of housing Maxium dimensions Avoir measured led ans logement de la terra Overdig un tro pas 150 200 mm Layer and level 4 5 mm pea gravel allowing Grainage outlet Posez en couches et nivelez 4 5 mm pos Gravier qui autorse le deboich grainage Install and level in ground housing unit and Connect all piperwork and check that Everithi
10. triche che escono dal pozzetto Ter em conta que a altura dos tubos de sa da de gua da piscina tem que estar colocados a urna altura mais baixa que as sa das da caseta ou em caso contr rio ajustar ao conjunto uma valvula anti retorno Prever subidas bruscas de pressao durante as operacos de lavagem e escoamento do filtro ter em conta que a alimentacao el ctrica debe ser de qualidade e que os cabos sejam da seccao necess ria A caseta tem que estar como m nimo a uma dist ncia de 3 m do plano da gua da piscina respetar a norma EDF C 15 100 Ruido depender da qualidade da bomba Coloqu juntas anti vibratorias na base da bomba para absorver assim vibracoes SICHERHEITSHINWEISE Die die Arbeiten ausf shrende Person oder Firma muB dabei die Beschaffenheit des Bodens an der Stelle wo das H uschens errichet werden soll ber cksitchtigen In Eieinzelf llen kann in Anpasung an die nat rliche Umgebung eine Abwandlung der im Handbuch des Produktes angegebenen Instruktionen notwendig sein Die unterirdisch liegenden Gehduseteile sollen mindestens 5 mm ber die Oberfl che hinauseagen um die Gefahr von Uberschwemmungen zu vermeiden Wahrend des Winters sollten Sie gegen Einfrieren resistente Materialien benutzen Stellen Sie sicher daB die Pumpe nicht direktem Kontakt mit Eis ausgesetzt ist Wir empfehlen diese zusammen mit den elektrischen Teilen in trockener Umgebung auszubauen Das man f llte von den B schungen die e
11. wash and rinse operations be careful about electrical feeding quality s and cable s secton size House holdings must be installed ar a minium of 3 meters far from pools water plane following EDF C15 100 Standards Noise Depending of pumps quality there is the possibility to assemble a gume protection under the pump to absorve vibrations and supress noises ADVERTISSEMENTS DE S CURIT L entreprise d installation devra appr cier la nature des sols et prendre toutes les dispositions n cessaires et ad quates pour contenir les remblais autour du local technique et viter ainsi une pression excessives ur les parois de ce dernier pour drainer les eaux d infiltration et les remont es de nappes phreatiques La partie enterrable doit d passer au minimum de 5 cm du sol fini pour viter les risques par inondations par le dessus fortes pluies En hivernage les mat riels doivent tre mis hors gel Conseil d monter et remiser la pompa et lourte partie lectrique au sec Les remblais doivent tre soigneaux et ne pas alterer ou d grader les canalisations et c bles au contact du local Les canalisations de la piscine doivent arriver au niveau des travers es du local en diam tre ad quat Dans le cas contraire disposer des clapets anti retour si motopompe pas en charge Pr voir une vidange en pression pour les lavages et contre lavages du filtre ainsi que l alimentation lectrique en qualit et section ad quates