1. as long as the unit is plugged in Hour Meter Display The cumulative hours will be displayed during normal operation If the unit is off even unplugged pressing the hour button figure 4 will also display the accumulative hours briefly Venting Ducting Twin rear outlets figure 5 can accommodate two individual 5 ducts or one 10 lay flat duct to be attached This allows for warm dry air to be directed into different areas Maintenance Air Filter The air filter should be checked regularly Operating the dehumidifier with a clogged filter will reduce efficiency To access the filter slide the filter frame up until it clears the dehumidifier cabinet figure 6 Reverse procedure to re install the filter into the dehumidifier Metal filters should be washed with soap and water and paper filters should be replaced Paper filter size is a nominal 12 x 12 x 1 Operating the unit without the filter in place will cause reduced efficiency due to dirty coils and increase the frequency of internal coil cleaning Stacking The dehumidifiers can be stacked on top of each other figure 7 The wheels from the upper unit must be resting in the cradle of the lower unit DO NOT STACK MORE THAN TWO HIGH Battery Replacement Disconnect power supply before replacing battery Failure to follow these instructions can result in death fire or electrical shock Disconnect dehumidifier from power supply The hour meter uses a battery backup for d
2. Item 405037 Rev Date 2015 06 01 Installation and Maintenance Manual Manual de Instalacion y Mantenimiento EPD Series Industrial Dehumidifier Deshumidificador industrial EPD150LR e EPD180CR e EPD190LR e EPD250CR United States 10048 Industrial Blvd Lenexa KS 66215 Tel 800 747 1762 e Fax 800 487 9915 Canada 90 Kanalflakt Way Bouctouche NB E45 3M5 Tel 800 565 3548 e Fax 877 747 8116 2 oe f I h d A E C Warning Important note WARNINGS Plug into a grounded 3 prong outlet Do not remove ground prong Do not use and adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING The dehumidifier uses a high pressure refrigerant system and high voltage circuitry which could present a health hazard resulting in death serious bodily injury and or property damage Only qualified ser vice people should service this unit CAUTION Do not operate unit without the front hood secured in place The serial data plate is located on the underside of the dehumidifier For service information contact 1 800 565 3548 gt fantech Information Technical information Practical tip ADVERTENCIAS Conecte a un contacto de pared de conexi n a tierra de 3 terminales No quite la terminal de conexi n a tierra No use un adaptador No use un cable el trico de extensi n No seguir estas instrucciones puede ocasio
3. a suciedad de las bobinas y a un aumento en la frecuencia de limpieza de las bobinas internas Colocaci n en vertical Puede apilar los deshumidificadores uno encima del otro figura 7 Las ruedas de la unidad que se coloque encima deber n apoyarse en los huecos de la unidad colocada abajo NO APILE M S DE DOS UNIDADES g fantech Figura 6 Figura 3 Figura 4 Figura 5 Figura 7 Cambio de la bateria Desconecte la toma de corriente antes de limpiar No seguir estas instrucciones podria provocar incendios descargas el ctricas e incluso la muerte Desconecte el deshumidificador de la toma de corriente El indicador de horas de operaci n utiliza una bater a para que pueda ser operativo si el aparato no esta enchufado se presiona el bot n de horas Para cambiar esta bater a tendr que desatornillar los cuatro 4 tornillos del panel de instrumentos Desconecte la bater a agotada y sustit yala por una nueva Vuelva a colocar el panel de instrumentos y los tornillos sin apretarlos en exceso Limpieza Desconecte la toma de corriente antes de limpiar No seguir estas instrucciones podr a provocar incendios descargas el ctricas e incluso la muerte Limpieza del exterior Utilice una soluci n de jab n suave no abrasivo ni inflamable y agua limpia para limpiar el deshumidificador Pase un trapo para secarlo Limpieza del interior Desconecte el deshumidificador de la toma de corriente Limpieza li
4. cuta cada 45 minutos a temperatura ambiente fr a menos seguido a temperatura ambiente c lida y la cantidad de tiempo en descongelamiento variar seg n corresponda Debe esperarse un congelamiento intenso en la bobina durante condiciones ambientales bajas pero esto no afectar el funcionamiento de la unidad gt fantech 8 Modo de apagado Si pulsa el bot n de encendido luego del primer minuto de funcionamiento iniciar el modo de apagado Este modo durar 15 minutos y mantendr el funcionamiento del ventilador y la bomba de purga para asegurar que se elimine toda el agua de la unidad antes de moverla o almacenarla Si se pulsa el bot n de encendido en cualquier momento durante el modo de apagado la unidad se apagar inmediatamente salteando el resto del modo de apagado La unidad debe purgarse pulsando el bot n de purga si se saltea el modo de apagado para evitar el desborde de agua La pantalla se transformar en una cuenta regresiva durante el modo de apagado que indicar el tiempo restante antes de que la unidad se apague completamente Funciones Funci n de recuperaci n tras un corte de energ a En caso de un corte de energ a se conservar el ltimo estado de funcionamiento encendido apagado cuando se restaure la energ a el ctrica Funci n de purga de la homba Durante el funcionamiento normal la bomba vaciar autom ticamente el dep sito Si se pulsa el bot n de purga figura 3 la bomba funcionar d
5. de que la temperatura ambiente sea demasiado baja Aumente la temperatura mediante una fuente suplementaria e Est el filtro de aire limpio y el flujo de aire sin obstrucciones Limpie el filtro La unidad deber a tener un espacio libre de 10 pulg libre de obst culos en todas las direcciones e Est sucia la bobina del evaporador Limpie la bobina La unidad mueve algo de agua pero no tanto como se supone e El filtro de aire est sucio o el flujo de aire obstruido La unidad deber a tener un espacio libre de 10 pulg libre de obst culos en todas las direcciones Limpie el filtro de aire y aseg rese de que exista un flujo de alre espacio adecuado alrededor de la unidad e La bobina del evaporador est sucia Limpiela e Tuber as de escape restrictivas o retorcidas Ender celas El ventilador no funciona El compresor funciona brevemente pero luego se enciende y apaga c clicamente e Conexi n floja en el circuito del ventilador Verifique las conexiones e Ventilador obstruido y est tico Elimine la obstrucci n e Ventilador defectuoso Sustit yalo e Tablero de control defectuoso Sustit yalo 11 Diagrama de cableado LO Add LO0 61 82Z c O 41109 9 HOLIOVdVI d0553ddN09 1041N09 JIN0d1J313 MOVIE dULIOVAVI 43M01E HOSSIHdNWOJ NMO g 93M0 lg 1 o NMOHE MOTISA 3 N3389 dd 31YSN3GNOI Ov gz fan
6. e 2 the compressor will be off and the fan will continue to run The pump purge will be activated automatically The defrost cycle runs every 45 minutes in cool ambient temperature less often in warm ambient temperature and the length of time in defrost will vary appropriately Heavy frosting on the coil can be expected during low ambient conditions and will not affect the operation of the unit 4 Shut Down Mode Pressing the power button after the first minute of operation will initiate a shut down mode This mode will last 15 minutes and will maintain the operation of the fan and purge pump to insure all water 15 removed from the unit prior to moving or storing Pressing the power button at any time during the shut down mode will immediately shut down the unit and bypass the remainder of the shutdown mode The unit must be purged by pressing the purge button if bypassing the shutdown mode to avoid water overflow The display will change during shutdown mode to a countdown timer that will indicate the time remaining before the unit shuts completely off Functions Loss of Power Recovery Function In case of a loss of power the last run state ON or OFF will be maintained when the power 15 restored Pump Purge Function In normal operation the pump will automatically empty the reservoir Pressing the purge button figure 3 runs the pump for 1 minute allowing manual emptying of the reservoir The pump purge will function in all modes
7. e unit No warm air ambient temperature may be too low Raise temperature with supplementary source e 5 the air filter clean and airflow unobstructed Clean filter Unit should have a minimum of 10 clearance all around it e Dirty evaporator coil Clean coil Unit moves some water but not as much as expected e Air filter dirty or airflow obstructed Unit should have a minimum of 10 clearance all around it Clean air filter and ensure adequate airflow space around unit e Evaporator coil dirty Clean coil e Restrictive or kinked exhaust ducting if used Straighten out ducting Fan does not run Compressor runs briefly but cycles on off e Loose connection in fan circuit Check connections e Fan obstructed and not turning Remove obstruction e Defective fan Replace fan e Defective control board Replace control board LO 100 61 18 70 O 3109 95 HOLIJVAVJ 55369 00 avoa 1041N09 JINOH19373 MOVIE HO LIJVdVI d3MO lg 55369 00 Y CN AY NMO g 5 NMOHE MOTA 3 N3389 dd SIVSNSCNOD A JUHM Wiring Diagram Deshumidificador industrial Requisitos el ctricos Para operar el deshumidificador a 115V es preciso el uso de un enchufe normal con toma de tierra y circuito de 15 amp Es preciso utilizar un interruptor ade escape a tierra si la unidad se va utilizar en un rea especialmente h meda S
8. ea en la que quiera reducir la humedad Compruebe que las puertas y ventanas est n cerradas al exterior y a sle la zona h meda de cualquier otra zona no afectada Introduzca la manguera de condensaci n en un desag e o en un contenedor de grandes dimensiones Presione el interruptor On Off para activar el deshumidificador figura 1 Modo de arranque Puede prender o apagar el deshumidificador apretando el bot n de corriente figura 1 Cuando se inicie el deshumidificador el contador de horas mostrar brevemente el n mero de versi n de software seguido de las horas acumuladas Figura 1 E Si se pulsa el bot n de encendido durante el primer minuto la unidad entrar en modo apagado inmediatamente x NN N Figura2 222222 Modo de funcionamiento Durante el modo de funcionamiento el compresor esta funcionando lo que hace que se enfrie el evaporador dando como resultado la formaci n de condensaci n en la bobina La unidad permanecer en modo de funcionamiento durante una cantidad variable de tiempo dependiendo de las condiciones ambientales Si se pulsa el bot n de encendido figura 1 se enviar la unidad a modo de apagado ver a continuaci n Modo de descongelamiento Durante el modo descongelamiento el indicador luminoso se encender figura 2 el compresor estar apagado y el ventilador seguir funcionando La purga de la bomba se activar autom ticamente El ciclo de descongelamiento se eje
9. er otra garantia anterior GARANTIA DE UN ANO Se garantiza este producto contra defectos de fabricaci n y materiales por un periodo de un afo a contar a partir de la fecha de compra del comprador original Todas las partes y la mano de obra estaran cubiertas sin coste alguno durante este periodo Las partes de reemplazo habitual bombillas y filtros por ejemplo no estan cubiertas por la garantia ni se garantizan durante periodo de tiempo alguno Esta garantia no puede transferirse GARANT A ADICIONAL DE SEIS A OS Durante un periodo de seis a os a contar desde la finalizaci n de la GARANT A DE UN A O los componentes del sistema precintado est n cubiertos en caso de que las piezas mostraran alg n defecto Se entregar n las piezas de manera gratuita tras prepago de costos de env o Los costes de mano de obra para la instalaci n no est n cubiertos por la garant a Esta garant a no puede transferirse GARANT A DE POR VIDA EN LA CAJA ROTOMOLDEADO La caja rotomoldeado de este producto cuenta con una garant a de por vida Esta garant a no es transferible AVISO 1 Esta garant a es v lida solamente para el comprador original y dentro de las fronteras de Canad y la parte continental de Estados Unidos 2 Esta es la nica garant a del vendedor y de Fantech Limited para el producto mencionado arriba Ning n otro tipo de garant a o condici n expl cita o impl cita ser aplicable excepto en casos espec ficamente excl
10. gera Saque el aire del filtro y roc e el serpent n evaporador con agua Limpieza profunda Desatornille los dos tornillos de la parte superior de la cubierta frontal Abra la cubierta Roc e los serpentines con agua Cierre la cubierta y vuelva a colocar los tornillos figura 8 Debe tenerse cuidado de no da ar l minas de la bobina ya que las l minas da adas pueden restringir el flujo del aire y reducir la capacidad de la unidad para producir agua Almacenamiento Las temperaturas bajo cero y el crecimiento biol gico deben considerarse antes de almacenar el deshumidificador Para evitar el crecimiento biol gico roc e un limpiador de evaporador sobre las bobinas y enjuague hacia el sistema de drenaje Tambien debe purgar el exceso de l quido de la bomba usando la funci n de purga manual para evitar problemas en ambientes de almacenamiento bajo Cero Figure 8 10 Solucion de problemas Servicio Un t cnico de refrigeraci n calificado debe reparar todas las fugas de refrigerante La unidad NO funciona e Se ha disparado el disyuntor Restablezca el disyuntor e Si la unidad se encuentra en un rea h meda est enchufada en un circuito protegido por un disyuntor diferencial La humedad excesiva disparar el disyuntor diferencial Al jela de esa rea e Est la unidad conectada a un generador Verifique que la tensi n de salida no fluct e ya que la unidad no funcionar con baja tensi n e Si e
11. isplay when the dehumidifier is unplugged and the hour button is depressed To change the battery it is necessary to remove the four 4 screws from the control panel Disconnect the old battery and replace with new battery Replace control panel and screws Do not overtighten screws g fantech Figure 6 Figure 3 Figure 4 Figure 5 Figure 7 Disconnect power supply before cleaning Failure to follow these instructions can result in death fire or electrical shock External Cleaning Use a non flammable mild non abrasive soap and water solution Wipe dry Internal Cleaning Disconnect dehumidifier from power supply Light cleaning Remove the air filter and spray evaporator coil with water Figure 8 Heavy cleaning Remove two upper screws from front hood Open hood Spray water at coils Close hood and replace screws figure 8 Care must be taken to insure coil fins are not damaged as damaged fins can restrict airflow and reduce the unit s ability to produce water Storage Freezing temperatures and biological growth must be considered before storing the dehumidifier To prevent the biological growth spray an evaporator cleaner on the coils and rinse into the drainage system You must also purge the excess liquid from the pump using the manual purge function to prevent issues with freezing storage environments Troubleshooting Service A qualified refrigeration technician must service all refrige
12. istema integrado de seguridad el ctrica Para proporcionarle mayor seguridad este electrodom stico est fabricado con una clavija con toma a tierra incluida en el cable de toma de corriente El cable debe enchufarse a un recept culo de corriente adecuado y con toma a tierra Un electricista acreditado deber instalar un enchufe con toma de tierra si no dispone de uno No corte ni elimine la patilla de toma a tierra de la clavija si sta viniera incluida en el equipo Le recomendamos que el circuito el ctrico o enchufe opere bajo un cortacircuitos o fusible aparte En caso de que necesite un cable de extensi n el cable deber contar con conductores de calibre m nimo de 14 gauge si es de 25 pies o m s corto y de calibre 12 gauge si es m s largo de 25 pies secci n de 3 31 y 2 08 mil metros cuadrados respectivamente Limitaci n de la utilizaci Temperatura 4 C a 35 C 40 F a 95 F Humeda relativa 20 a 80 Extracci n de agua El deshumidificador incluye una bomba interna de condensaci n que elimina el agua sustra da del aire Este sistema permite evacuar el agua hasta a 20 pies de distancia utilizando la manguera incluida En caso de que necesite evacuar el agua a una distancia mayor a 20 pies deber instalar otra bomba capaz de evacuar el agua a partir de este punto La bomba de condensaci n evacua el agua de manera autom tica cada cuatro minutos y durante 20 segundos Funcionamiento Coloque el deshumidificador en el r
13. nal la muerte incendio o choque el ctrico ADVERTENCIA El deshumidificador utiliza un sistema de l quido refriger ante de alta presi n y un circuito el ctrico de alto voltaje que podr an resultar en da os materiales peligro para la salud lesiones corporales graves e incluso la muerte S lo personal cualificado debe dar servicio a esta unidad PRECAUCI N No utilice la unidad hasta haber asegurado la cubierta fron tal en posici n cerrada La placa serial est situada en el superficie inferior del deshumidificador Consulte con el n mero 1 800 565 3548 para m sinformaci n sobre Servicio Industrial Dehumidifier Electrical Requirements For 115V operation a common grounded outlet on a 15 amp circuit is required If used in a wet area a ground fault interrupter GFI is required Built in Electrical Safety For your safety and protection this appliance is manufactured with a grounded plug on its power cord The power cord must be plugged into a properly grounded receptacle If a grounded receptacle does not exist have one installed by a certified electrician Do not cut or remove the grounding prong on the power cord plug if equipped We recommend that this electrical circuit receptacle operate under a separate breaker or fuse If an extension cord is required it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 feet long Limitations of Use Temperature 4 C t
14. o 35 40 F to 95 F Relative Humidity 20 to 80 Water Removal The dehumidifier is equipped with an internal condensate pump to remove the water that is collected from the air This allows the water to be pumped 20 feet with the attached hose If the water needs to be pumped more than 20 feet above the unit a second pump must be added to relay the water The condensate pump automatically purges for 20 seconds every four minutes Operation Place dehumidifier inside area to be dried Make sure all windows and doors are closed to the outside and seal off the wet area from any unaffected areas Route condensate hose into a drain or a very large container Press the On Off button figure 1 to activate the dehumidifier Start up Mode The dehumidifier is turned on or off by pressing the power button figure 1 When the dehumidifier is started the hour meter will briefly display the software version followed by the cumulative Figure 1 hours Pressing the power button during the first minute the unit will go into OFF Mode immediately Run Mode During Run Mode the compressor is running causing the evaporator to get cold resulting in condensate forming on the coil The unit will stay in run mode for variable length of time depending on the ambient conditions Pressing the power button figure 1 will send the unit in shut down mode see below Defrost Mode During the defrost mode the indicator light will turn on figur
15. ra disturbios hostilidades casos de fuerza mayor del tipo huracanes inundaciones etc Para obtener informaci n relativa a la garant a comun quese con En CANADA Fantech 90 Kanalflakt Way Bouctouche NB E45 3M5 Phone 800 565 3548 506 743 9500 Fax 877 747 8116 506 743 9600 En Estados Unidos continental Fantech 10048 Industrial Blvd Lenexa KS 66215 Phone 800 747 1762 913 752 6000 Fax 800 487 9915 913 752 6466 email service fantech net NOTES gt fantech NOTAS gt fantech Fantech reserves the right to make technical changes Fantech se reserva el derecho de hacer modificaciones For updated documentation please refer to www fantech net t cnicas en cualquier momento Para obtener la documen taci n actualizada por favor consulte www fantech net Fantech i fantec
16. rant leaks The Unit is NOT working e Has the breaker tripped Reset breaker f in a wet area is the unit plugged into a GFI protected circuit Excessive moisture will trip GFI Remove from area e 5 the unit being run off a generator Check output does not fluctuate as the unit will not operate at low voltage e f using an extension cord ls the cord of the correct gauge for the distance run 14 AWG up to 25 and 12 AWG over 25 Note Verify voltage while unit is starting Start up will cause the highest current draw and largest voltage drop Even if plugged directly to outlet there can be a significant voltage drop Never assume the voltage is ok without verifying The unit shuts down and displays an error code ER 1 Overflow switch remaining closed for gt 2 minutes e Plugged or kinked drain hose Remove obstruction e Bad connection in pump circuit Check connections e Defective condensate pump Replace ER 2 Internal pressure switch indicates refrigerant pressure is too high e Air filter is dirty or plugged Clean or replace air filter e The coil is dirty Clean the coil e Loose or faulty electrical connections to pressure switch check connections e Fan is not working Replace e Defective pressure switch replace The unit continually ices up Note that some ice buildup on the evaporator coil is normal but airflow should not be blocked e 5 warm air blowing out the back of th
17. roof 5 Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives specific legal rights and the purchaser may have other rights which vary from state to state For more information regarding legal rights the purchaser may contact the local or state consumer affairs office or the appropriate state Attorney General gt fantech GENERAL PROVISIONS No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following 1 Power failure 2 Damage in transit or when moving the appliance 3 Improper power supply such as low voltage defective house wiring or inadequate fuses 4 Accident alteration abuse or misuse of the appliance such as Inadequate air circulation in the room or abnormal operating conditions extremely high or low room temperatures O Fire water damage theft war riot hostility acts of God such as hurricanes floods etc For information concerning your warranty contact In Canada Fantech 90 Kanalflakt Way Bouctouche NB E45 3M5 Phone 800 565 3548 506 743 9500 Fax 877 747 8116 506 743 9600 In Continental USA Fantech 10048 Industrial Blvd Lenexa KS 66215 Phone 800 747 1762 913 752 6000 Fax 800 487 9915 913 752 6466 email service fantech net GARANTIA Garantia por un 1 Anos Esta garantia de sin efecto cualqui
18. st conectada mediante un alargador posee dicho alargador el grosor adecuado para su longitud 14 AWG hasta 25 pies y AWG para m s de 25 pies Nota Verifique la tensi n mientras la unidad est arrancando El arranque causar el mayor consumo de corriente y la mayor ca da de tensi n Aun estando conectada directamente al tomacorriente puede haber una significativa ca da de tensi n Nunca suponga que la tensi n es la correcta sin comprobarlo La unidad se apaga y muestra un c digo de error ER 1 El interruptor de desborde permanece cerrado por m s de 2 minutos e Manguera de drenaje tapada o retorcida Elimine la obstrucci n e Mala conexi n en el circuito de la bomba Verifique las conexiones e Bomba de condensado defectuosa Sustit yala ER e El interruptor de presi n interna indica una presi n del refrigerante demasiado alta e El filtro de aire est sucio u obstruido L mpielo o sustit yalo e bobina est sucia Limpiela e Conexiones el ctricas flojas o defectuosas hacia el interruptor de presi n Verifique las conexiones e El ventilador no funciona Sustit yalo e Interruptor de presi n defectuoso Sustit yalo gt fantech unidad se congela continuamente Tenga en cuenta que es normal la acumulaci n de cierta cantidad de hielo en el evaporador pero no debe bloquear el flujo del aire e Sale aire caliente por la parte trasera de la unidad No hay aire Caliente pue
19. tech 12 WARRANTY One 1 Year Warranty This warranty supersedes all prior warranties WARRANTY ONE YEAR This product is warranted against defects in material and workmanship for a period of one year from the date of purchase by the original purchaser During this period all parts and labor will be provided at no cost Consumable parts light bulbs and filters are not warranted or guaranteed for any length of time This warranty is non transferable ADDITIONAL SIX YEAR WARRANTY For a period of six years following the ONE YEAR WARRANTY components of the sealed system are warranted against defects in material Parts will be supplied freight prepaid free of charge Installation labor is not covered This warranty is non transferable LIFETIME WARRANTY ON ROTOMOLDED HOUSING The Rotomolded housing of this product carries a lifetime warranty This warranty is non transferable NOTICE 1 This warranty applies only to the original purchaser and applies only within the boundaries of CANADA and CONTINENTAL USA 2 This is the only warranty of the dealer and Fantech Limited for the above mentioned product and no other warranty or condition expressed or implied shall apply except where specifically excluded by law 3 The original purchaser should complete this warranty form and retain it in the event warranty service 15 required 4 Proof of purchase date will be required for warranty claims Please retain bills of sale for p
20. uidos por ley 3 El comprador original deber completar el formulario de garant a y conservarlo para poder utilizarlo en caso de que sea preciso dar servicio al producto 4 cualquier reclamaci n de garant a ser preciso contar con una prueba de compra con fecha Recuerde guardar el recibo como comprobante de venta En algunos estados no se permite la exclusi n o limitaci n de da os consecuentes o secundarios en estos casos la limitaci n anterior podr a no aplicar a su caso Esta garant a ofrece derechos legales espec ficos el comprador puede contar con otros diferentes dependiendo del estado Si necesita m s informaci n sobre los derechos legales del comprador puede consultar con la oficina del consumidor local estatal o con el fiscal de su estado 13 PROVISIONES GENERALES La garant a o seguro contenidos o establecidos aqu no ser n aplicables cuando el da o o la reparaci n consecuentes sean resultado de alguno de los siguientes 1 Fallo del suministro el ctrico 2 Da os durante el transporte o traslado del electrodom stico 3 Suministro el ctrico inadecuado del tipo voltaje bajo cableado deficiente en la casa o fusibles no adecuados 4 Accidente alteraci n abuso o mal uso del electrodom stico del tipo circulaci n de aire inadecuado en el cuarto o condiciones anormales de operaci n temperaturas demasiado altas o demasiado bajas en el cuarto Fuego agua da o robo guer
21. urante 1 minuto permitiendo el vaciado manual del dep sito La purga de la bomba funcionar en todos los modos siempre que la unidad se encuentre enchufada Pantalla del contador de horas Mostrar las horas acumuladas durante el funcionamiento normal Si la unidad se encuentra apagada incluso desenchufada al pulsar el bot n de hora figura 4 tambi n se mostrar n brevemente las horas acumuladas Ventilaci n tubos de ventilaci n El aparato cuenta con dos orificios que permiten la instalaci n de dos tubos individuales de 5 pulgadas 12 7 o de uno solo de 10 pulgadas plano 25 4 De este modo se puede dirigir el aire caliente a zonas diferentes Mantenimiento Filtro del aire Debe comprobar el estado del filtro del aire con frecuencia Si opera el deshumidificador con un filtro taponado reducir su eficiencia Puede pasar una aspiradora por el filtro para eliminar el polvo ara acceder al medio del filtro deslice el marco del filtro hacia arriba hasta extraerlo por completo del aparato figura 6 uite el medio del filtro de la parte trasera del marco y pase una aspiradora Haga el proceso a la inversa para instalar el filtro y el marco en el deshumidificador Los filtros met licos deben lavarse con agua y jab n y los filtros de papel deben reemplazarse El tama o nominal del filtro de papel es de 12 x 12 x 1 pulg Operar la unidad sin el filtro en su lugar dar como resultado una eficiencia reducida debido a l