Manual de Instalación Pulsador Manual compacto IQ8
Contents
1. S MANN MATAN i AATA ONO A CON LN Y ONO LO TFNO 3 O oo Seso U 0 0 Seasg U a Sesa U gg 3533 55 2333 T 35 bob zA 3 ZA 3 A N s 3 gt ER N E F KAN E e rd O a E NY s E 1 S Q e x y e a E S i ssl Analog Ring Modul Ma a Analog Loop Module HA RE m A e z a e pz pd Hi IR Jj 53 nn rro E zE y E EEEE P E Banann E aa po MAA p o A MO O A O e CETELE e Pie po Pi m aA s J d n e EET A 4 ze AS Figura 10 Conexionado de lazo anal gico Fig 10 Analog loop wiring
2. aplicada o la informaci n facilitada Para obtener la informaci n actualizada para mantenimiento o configuraci n de los sistemas contacte con su proveedor para que se la facilite o en www esser systems de Siguiendo normas de instalaci n de VdS no es posible configurar VdS Pulsadores y Detectores en la misma zona de Detecci n max 10 MCP por zona de detector La conexi n de una zona externa a este Pulsador IQ8 no est regulado por la normativa Vds When the MCP is used as a manual call point it must be installed A in a red housing with an identification label showing the standardize conformal symbol as shown in Fig 3 4 When housings with different colours and identification labels are used the unit is classed as a manual activation device and not as a manual call point Observe the correct wiring sequence for the analog loop Terminals 1 4 ULin Input ULour Output Use designated communication cable l Y St Y n x 2 x 0 8 mm or fire alarm cable Connection of the cable shield to the ground terminal protects the signal cables against interference The alarm activation and triggering of notifying systems e g manned centre link Master box must be observed during any Service of the MCP Install inlying cable with a dripping bend to protect the device from dampness Additional and updated Informations The product specification relate to the date of issue and may differ due to modifications and or amended
3. espacios secos no sujetos a riesgos de explosi n El pulsador tambi n est disponible en otras versiones para otras aplicaciones por ejemplo en carcasas de diferentes colores y con elecci n de diferentes colores o etiqueta de identificaci n ver tabla p gina 2 El modo de operaci n se indica mediante el parpadeo del led verde LED 1 H ver Fig 4 Funccionamiento B Revise sta informaci n Activar Alarma Presione el cristal hacia adentro hasta que aparezca la leng eta amarilla G en la zona superior de la ventana y el LED Rojo F parpadee Fig 4 Suba la cubierta de llave A e inserte la llave Rearme Pulsador con Cristal Abra la caja y retire el cristal Gire la llave C en sentido horario hasta el tope derecho M Fig 5 Abra la cubierta y reemplace el cristal gire la llave en sentido contrahorario hasta el tope izquierdo N para subir la l mina Fig 6 Pulsador con l mina rearmable Gire la llave C en sentido horario hasta el tope derecho M Fig 5 Coloque la l mina K correctamente y gire la llave en sentido contrahorario hasta el tope izquierdo N para subir la l mina Fig 6 Prueba Gire la llave C en sentido horario hasta el tope derecho M hasta que la l mina caiga y se indique la activaci n F G Fig 4 Para rearmar el equipo gire la llave en sentido contrahorario hasta el tope izquierdo N para subir la l mina Instalaci n Montaje El pulsador puede instalarse sobre c
4. key lock clockwise until the right stop position operating panel Fig 5 Insert screen aligned J L in the front recess or und move screen upwards by turning the key anti glass screen clockwise until the left stop position Fig 6 Terminals The screw terminals 1 8 can be removed to simplify the installation Fig 10 The cable shield of the connection cable must be interconnected by using a single terminal block The back box option provides an integrated screw terminal for the shield connection Fig 7 Hinged cover To protect the detector for unintended activation and to Part No 704965 increase the protection rating from IP 43 up to IP 55 Option The hinged cover O is fixed by the sideway dents P of the housing and may be sealed B if required Fig 2 9 Typical wiring Fig 10 The MCPs are connected to the analog loop of the System 8000 or IQ8Control fire alarm control panel Manual call points must be configured together in their own detector zones Connect the detector zone connection cable to terminals 1 4 Call point with zone isolator and ext D Line The zone isolators ensure that the system continues to function even if a segment of the loop circuit fails due to a short circuit When a short circuit occurs the zone isolators before and after the short circuit open disconnecting the section of the loop between the isolators Simple wire breaks do not affect the functionality of the loop circuit An ext
5. ESSER by Honeywell Manual de Instalaci n Pulsador Manual compacto 1Q8 Installation Instruction IQ8Electronic module Manual Call Point Ref Part No 804955 804971 Cambios t cnicos reservados 798936 05 2007 Technical changes reserved Novar GmbH a Honeywell Company Dieselstra e 2 D 41469 Neuss Internet www esser systems de E Mail info esser systems de CE Cuando se usa un Pulsador IQ8 como pulsador de Alarma se debe usar una carcasa roja con una etiqueta de identificaci n con el s mbolo correcto como es mostrado en Fig 3 y 4 Cuando se usan diferentes carcasas o diferentes s mbolos el equipo est clasificado como equipo de activaci n y no como Pulsador de Alarma Observe la secuencia correcta en el cableado de lazo anal gico Terminales 1 4 UL Entrada gt UL our Salida Use cable de comunicaciones claramente identificado l Y St Y n x 2 x 0 8 mm o cable para alarma de incendio La conexi n de la malla del cable debe realizarse al Terminal de tierra para evitar interferencias Use junta de paso para cableado para evitar el acceso de humedad Se debe tener en cuenta durante el mantenimiento o labores de reparaci n la activaci n de sistemas de aviso como por ejemplo activaci n a central receptora Informaci n adicional y actualizada Las especificaciones se refieren al la fecha de creaci n del documento y pueden ser modificadas o variadas sobre la normativa
6. Standards and Regulations from the given informations For updated informations to commissioning and maintenance of Fire alarm detectors refer to www esser systems de Pursuant to the VdS guidelines MCPs and automatic fire VdS detectors must not be operated in a common detector zone max 10 MCP per detector zone Connection of an external detector zone D Line to this IQ8 MCP is not in accordance to the VdS guidelines By using the mounting frame Part No 704967 the white covering must be fitted Importante Se declina toda responsabilidad sobre da os derivados y garant a por no seguir estas instrucciones de instalaci n Estas instrucciones deben ser tenidas en cuenta cuidadosamente antes de proceder a la puesta en marcha del m dulo electr nico IQ8 Pulsador Manual de Alarma IQ8 Informaci n de seguridad NUNCA conecte el pulsador directamente a 220V ac Instale el pulsador dentro el rango de temperatura especificado Solo t cnicos cualificados que est n familiarizados con los riesgos espec ficos y las normativas correspondientes deben llevar a cabo las operaciones de reparaci n y mantenimiento del Pulsador El pulsador no debe ser alterado ni modificado General El pulsador electr nico IQ8 Ref 804955 y respectivamente el pulsador manual Ref 804971 con carcasa roja est identificado con un s mbolo de una casa ardiendo para activaci n manual de sistemas de alarma u otros sistemas en
7. aja de mecanismo empotrado est ndar Y 55 60mm Montaje en El pulsador se instala sobre caja sde superficie opcional o Superficie con marco de montaje universal opcional Instale el Pulsador de un modo seguro en una pared apropiada sobre una superficie lisa con los tornillos y tacos adecuados Fig 7 8 Apertura Inserte la llave por sus dos patillas en los orificios inferiores de la cubierta abajo Presione hacia arriba para liberar la tapa Fig 2 Tire desde abajo hacia fuera hasta retirar la tapa Cierre Gire la llave en sentido contrahorario hasta su tope izquierdo Fig 6 Coloque la leng eta superior de la cubierta sobre las ranuras del m dulo del pulsador y presione hasta encajar la cubierta en su posici n S mbolo Abra la carcasa como se ha indicado y quite la l mina transparente de pl stico D E presionando hacia afuera coloque el pictograma adecuado en el frontal coloque de nuevo la l mina transparente sobre el nuevo pictograma y presione hasta su posici n Fig 3 Etiqueta Para indicar equipo fuera de uso K L mina de Gire la llave en sentido horario hasta el tope derecho pl stico o Fig 5 Inserte la l mina o cristal en su posici n J L en cristal el hueco frontal deslice la l mina hacia arriba girando la llave en sentido contrahorario Fig 6 Terminales Los terminales 1 8 pueden extraerse para facilitar la instalaci n Fig 10 La pantalla del cable debe interconectarse
8. ange e Only qualified technicians who are fully familiar with all the associated hazards and the applicable legislation and regulations may perform maintenance and repair work on the call point e The call point may not be changed or modified in any way General The IQ8Electronic module Part No 804955 respectively the Q8Manual Call Point Part No 804971 in the red housing identified with a burning house symbol is designated for use as a call point for manually triggering fire alarms or other hazard alarms in dry workplaces not subject to explosion hazards The call point is also available in other versions for other applications for example in housings with different colours and with a choice of different identification labels refer to table page 2 The operation mode is displayed via the flashing green LED H Fig 4 Operation i Observe Info Trigger alarm Press screen centre inwards until the yellow tab indicator G is visible in the upper area and the red LED F is flashing Fig 4 Push up the keyhole cover A to insert the key Reset Detector with glass screen Open housing and remove the broken glass Turn key C clockwise until the right L stop position Fig 5 Replace glass screen and turn key M anti clockwise until the left stop position to lift screen upwards Fig 6 Detector with plastic operating panel Turn key C clockwise until the right L stop position Fig 5 Align the p
9. de otros iconos 10 Uds L mina de pl stico rearmable L 10 Uds Cubierta transparente abatible O para protecci n de activaciones no intencionadas y aumento de grado de protecci n IP 43 a IP 55 Llave de repuesto 10 Uds Marco de monataje para pulsador compacto rojo blanco 132 x 132 x 8 mm Caja de montaje en superficie rojo similar RAL 3020 Caja de montaje en superficie azul similar RAL 5015 instalaci n Mounting 88 88 N A Fig 1 Dimensiones Figura 2 Apertura de la tapa carcasa Fig 1 Dimensions Fig 2 Open the housing seal PENAS A N Cristal Glass F G H F 7 de Aba Top MM Y 0 Indicador de Papel Paper inlay Arriba Top L mina rearmable Ref 704964 Plastic operating panel Part N 704964 0 Top Figura 4 Indicacidores LED y cubiertas de Pl stico rearmable cristal y papel fuera de uso Fig 4 Mechanical alarm indicator and LED Glass screen paper inlay and plastic operating panel Ref 704951 704960 704961 704964 704965 704966 704967 704980 704981 Figura 5 Posici n de llave para prueba extraer cristal Fig 5 Key lock position for test mode and removing screen Options Part No Housing for MCP blue similar to RAL 5015 704951 Replacement glass screen 10 pieces 704960 Label transparent with whit printing differing from standard icons 10 pieces 704961 Plastic operating panel L r
10. en regleta separada La caja de superficie tiene un terminal apropiado para conectar la pantalla opcional Fig 7 Cubierta Para proteger de activaciones no intencionadas y para Abatible aumentar el grado de protecci n de IP 43 a IP 55 Ref 704965 La cubierta abatible O se inserta en los orificios opcional laterales P de la carcasa y puede precintarse en caso necesario B Fig 2 9 Cableado T pico Fig 10 Los Pulsadores se conectan al lazo anal gico del Sistema de Detecci n de Incendios 8000 o IQ8Control Los Pulsadores deben configurarse juntos en sus propias zonas de detecci n Conecte los cables de la zona de detector a los terminales 1 4 Pulsador con aislador de zona y L nea Externa Ref No 804905 Los aisladores de zona sirven para asegurar el funcionamiento del sistema en caso de que se produzca una aver a en el lazo por ejemplo en caso de un cortocircuito Cuando esto sucede el aislador abre y desconecta la secci n del lazo entre los aisladores Aperturas de lazo no afectan al funcionamiento correcto del lazo Es posible conectar una l nea externa de detecci n D line con Pulsadores convencionales Resistencia en Alarma interior para cada Pulsador de 1 KOhm por ejemplo Ref No 804900 o 804901 a este modelo de Pulsador IQ8 Cuando se produce una alarma se muestra de modo autom tico la direcci n y la etiqueta programada del Pulsador IQ8 a la que el pulsador convencional est conectado La longitud tota
11. ernal detector zone D line with up to 10 standard manual call points internal Alarm resistor for each detector 1KOhm may be connected to a single 1Q8 Manual Call Point When an alarm is triggered the address and the programmed additional text of the 1Q8 Manual Call Point to which the standard zone is connected are displayed automatically The total cable length of the external call point zone should not exceed 500 meters Terminate the last call point of the external D line with a 10 KOhm End of line resistor Fig 10 If no external D line is connected the 10KOhm terminating resistor must be installed directly to terminals 7 8 Fig 10 Specification Power supply Quiescent current 19 V DC Alarm current 8 V DC to 42 V DC approx 45 JA O 19 V DC approx 9 mA pulsed No of call points max 127 MCP per loop Alarm indicator red LED yellow tab Operation indicator green LED Connection terminals max 2 5mm AWG 26 14 Application temperature 20 C to 70 C Storage temperature 30 C to 75 C Protection rating IP 43 in housing IP 55 with hinged cover Housing z PC ASA plastic Colour red similar RAL 3020 Weight approx 110 g Housing dimensions w x h x d Dimensions with back box 88 x 88 x 57 mm Call point specification EN 54 11 type A VdS approval G 205132 88 x 88 x 21 mm CE Opci n Carcasa Azul similar RAL 5015 Cristal de repuesto 10 Uds Etiqueta transparente para impresi n
12. esettable white 10 pieces 704964 Hinged cover O to protect the detector for unintended activation and to increase 704965 the protection rating from IP 43 up to IP 55 Replacement key 10 pieces 704966 Frame for small Manual Call Points incl cover red white 132 x 132 x 8 mm 704967 Back box for surface mounting red similar to RAL 3020 704980 Back box for surface mounting blue similar to RAL 5015 704981 ON 0 Er E Figura 3 Etiqueta de identificaci n Fig 3 Identification label Figura 6 Posici n de llave para rearme insertar cristal Fig 6 Key lock position for Reset Replace screen 132 8 8 1 36 gt 132 88 Figura 7 Caja de montaje en superficie Ref 704980 Fig 7 Back box for surface mounting Part No 704980 Sistema 8000 IQ8Control Figura 8 Marco de montaje universal Art Nr 704967 Fig 8 Universal installation incl cover Part No 704967 Figura 9 Cubierta abatible Ref 704965 Fig 9 Hinged cover Part No 704965
13. l de cable de la zona externa no debe exceder de 500m Inserte en el ltimo pulsador de la l nea externa una resistencia RFL de 10 KOhm Fig 10 Si no se conecta nada en la l nea externa D line se debe conectar una resistencia de 10 KOhm directamente en los terminales 7 8 Fig 10 Caracter sticas T cnicas Alimentaci n Consumo reposo O 19 V DC Consumo alarma 8 V cc a 42 V cc 45 uA aprox 9 mA aprox pulsante N mero Pulsadores max 127 por lazo Indicaci n alarma LED rojo l mina amarilla Indicador funcionamiento LED verde Terminales 2 5 mm m x AWG 26 14 Temperatura trabajo 20 C a 70 C Temperatura almacenamiento 30 C a 75 C Grado de protecci n IP 43 en carcasa IP 55 con cubierta abatible Caja z Pl stico PC ASA Color Rojo similar RAL 3020 Peso 110 g aprox Dimensiones a x h x f Diemnansiones con caja sup 88 x 88 x 57 mm Especificaci n EN 54 11 Typ A Certificado VdS z G 205132 88 x 88 x 21 mm Important Any damage caused by failure to observe the installation instructions voids the product guarantee Furthermore no liability can be accepted for any consequential damage arising from such failure These instructions must be studied carefully before installing and configuring the IQ8Electronic module Manual Call Point MCP Safety information e NEVER connect the MOP directly to a 230V AC mains power supply e Only operate in the specified ambient temperature r
14. lastic operating panel K and turn key M anti clockwise until the left stop position to lift screen upwards Fig 6 Test mode Turn key C clockwise L until the screen moves downwards and the activation F G is indicated Fig 4 To reset the detector after a test simply turn key M to the left stop position to lift screen upwards Installation Flush mounting The Manual Call Point is installed on a conventional standard housing 55 60mm Surface The Manual Call Point is installed on a back box for mounting surface mounting option or with an universal installation frame for wall mounting option The call point securely on a suitable wall with a smooth surface e g with 2 screws length gt 40mm and dowels S6 Figs 7 8 Opening Insert the key with the both tenons in the opening at the bottom of the housing Fig 2 to release the cover lock Lift up the bottom edge of the cover a little to release it and then remove it Closing Turn key lock anti clockwise until the left stop position Fig 6 Position the upper edge of the cover in the groove at the top of the base and then press the cover down until it locks into position Symbolism Open the housing and remove the transparent plastic cover D E by prising it out Insert the appropriate identification label from the front Align the cover and snap it back into place Fig 3 Paper inlay To indicate that the detector is out of order K Plastic Turn