1. Centerline of installation space Mounting the hood WARNING 2 people are required to lift and position the hood onto the mounting screws Place the template on the wall along the horizontal line make sure the template is leveled and centered with the centerline Mark upper screw holes locations in the wall IMPORTANT Check to be sure that hole locations are leveled and correctly centered by the vertical centerline e Drive2 5x45 mm upper wood screws by hand Leave Y of distance between the screw head and the wall Y 6 4mm x Remove the grease filter and mount the hood onto the upper Screws NOTE The screws provided for mounting this hood must be fastened into solid wood do not fasten into sheet rock only Complete preparation 1 Determine and make all necessary cuts in the wall for the vent system Install the vent system before installing the range hood See the Venting Requirements section 2 Determine the location where the power supply cable will be run through the wall 3 Drill a 174 3 2 cm hole at this location 4 Pull enough power supply cable through the wall to allow for easy connection to the terminal box 5 Install the 8 20 3 cm round vent transition with damper to top of the range hood using 4 3 5 x 9 5 mm screws Install Range Hood 1 as Using 2 or more people hang the range hood on the the wall by placing the slotted holes in the range hood bac
2. Remove the protective film covering the product before putting into operation Parts supplied Hood assembly with blower and light bulbs 8 Metalic Air Transition Duct covers Metal grease filters Hardware bag with Use care and installation guide Duct cover bracket T20 TORX t adapter 6 5x45 mm mounting screws 4 3 5 x 9 5 mm mounting screws 4 4 2x 8 mm mounting screws 2 8x40 mm wall anchors 4 10x 50 mm wall anchors Parts needed Home power supply cable Y 12 7 mm UL listed or CSA approved strain relief 3 UL listed wire connectors 1 wall or roof cap 8 round metal vent system Tools Materials required Level Drill with 1 3 2 cm 7s 3 2 mm and 6 7 9 mm drill bits Pencil Wire stripper or utility knife Tape measure or ruler Pliers Caulking gun and weatherproof caulking compound Vent clamps Jigsaw or keyhole saw Flat blade screwdriver Metal snips Product Dimensions m 30 75 7 cm 36 91 cm 42 106 2 es g 20 32 cm Max 52 132 cm Min 3777 95 3 cm Nd 61 cm Location Requirements IMPORTANT Observe all governing codes and ordinances Have a qualified technician install the range hood It is the installer s respon sibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood l
3. guichet Tournevis lame plate Cisaille de ferblantier Tournevis Phillips Dimensions et D gagement 10 26 9 cm MR 30 75 7 cm 36 91 cm 42 106 2 mee ed ae 20 32 cm Max 52 132 cm Min 37 95 3 cm q 12 30 8 cm pers 15 Exigences d emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Confier l installation de la hotte un technicien qualifi C est l installateur qu incombe la responsabilit de respecter les distances de s paration sp cifi es sur la plaque signal tique de l appareil La plaque signal tique est situ e l int rieur de la hotte sur la paroi arri re On doit toujours installer la hotte distance des sources de courant d air fen tres portes et vents de chauffage puissants Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Ces dimensions tiennent compte des valeurs mini males des d gagements de s paration Cette hotte a t configur e l usine pour une d charge travers le toit ou travers le mur Assurer l tanch it au niveau de chaque ouverture d coup e dans le plafond ou le mur pour l installation de la hotte de cuisini re Installation dans une r sidence mobile L installation de cette hotte doit satisfaire aux exigences de la norme Manufactured Home Construction Safety Standards Titre 24 CFR partie 328 ancie
4. D g t ou panne du produit caus par modification du produit ou utilisation de pi ces pas d origine D g t ou panne du produit caus lors de la livraison de la manipulation ou de l installation D g t ou panne du produit caus par une mauvaise utilisation D g t ou panne du produit caus par un remplacement des fusibles ou une remise en fonction des disjoncteurs par le propri taire D g t ou panne du produit caus par une utilisation du produit pour raison commerciale D placement domicile pour explication d utilisation ou d entretien Ampoules filtres m talliques ou au charbon et toute autre pi ce consommable Usure normale Usure due une mauvaise utilisation du propri taire un entretien incorrect une utilisation de substances nettoyantes cor rosives ou abrasives et produits de nettoyage pour four QUI EST COUVERT Cette garantie s tend l acheteur original de produits achet s pour un usage domestique habituel en Am rique du Nord Y compris Etats Unis Guam Porto Rico les lles virgin Am ricaines amp le Canada Cette garantie n est pas transf rable et vaut uniquement pour l acheteur original et ne s tend pas aux propri taires successifs du produit Cette garantie vaut express ment en lieu et place de toute autre garantie expresse ou sous entendue mais ne limite pas toute autre garantie sous entendue de marchandage ou adaptation dans un but particulier et toute autre obligation de
5. Pela cables 6 cuchillo Cinta m trica o regla Pinzas Pistola galafateadora y silic n para sellar a prueba de agua Sujetadores de ductos Serrucho o sierra caladora Destornillador plano Dimensiones del Producto NL 30 75 7 cm 36 91 cm 42 106 2 reel Max 52 Min 377 132 cm 95 3 cm 124 30 8 cm ad 61 cm 25 Requisitos de ubicaci n IMPORTANTE Observe todos los c digos y ordenanzas aplicables Haga que un t cnico capacitado instale la campana para cocina Es la responsabilidad del instalador cumplir con los espacios de insta laci n especificados en la placa con la clasificaci n de modelo serie La placa con clasificaci n de modelo serie est ubicada detr s del filtro en la pared posterior de la campana para cocina La ubicaci n de la campana deber estar lejos de zonas con cor rientes fuertes de aire tales como ventanas puertas u orificios de calefacci n fuertes Deben usarse las dimensiones de la abertura del gabinete que se muestran Las dimensiones proporcionadas proveen los espacios m nimos Se requiere un enchufe el ctrico con conexi n a tierra Vea la secci n Requisitos el ctricos La campana se ha ajustado de f brica para tener una ventilaci n a trav s del techo o de la pared No est disponible en versi n recircu lante Todas las aperturas en el techo o pared deber n ser selladas Para la instalaci n en casas rodantes La i
6. doigts nus Remplacer la lampe en la manipulant avec un mouchoir de papier ou des gants de coton Si les nouvelles lampes ne fonctionnent pas v rifier que chaque lampe est correctement ins r e dans sa douille avant de demander l intervention d un d panneur 1 D connecter la source de courant lectrique 2 l aide d un tournevis lame plate d gager le prot ge ampoule avec pr caution 3 Enlever la lampe et remplacer par une lampe halog ne neuve de 120 V 40 W maximum culot de type G 9 4 R installer le prot ge ampoule 5 Reconnecter la source de courant lectrique Nettoyage Surfaces externes Afin d viter d endommager la surface externe ne pas utiliser de tampons en laine d acier ou de tampons r curer savonneux Frotter dans la direction des lignes du grain pour ne pas d t riorer la surface Toujours essuyer pour viter de laisser des marques d eau m Nettoyant et poli pour acier inoxydable m D tergent liquide doux et eau m Frotter avec un chiffon doux humide ou une ponge non abrasive puis rincer avec de l eau propre et essuyer Filtres m talliques et plateaux d gouttement 1 Utiliser les 2 mains pour retirer les filtres 2 Saisir les poign es du filtre tirer vers l avant de la hotte et tirer sur la poign e arri re pour retirer le filtre R p ter pour chaque filtre A Filtre graisse 3 Retirer le plateau d gouttement grais
7. se necesita un codo de 90 Descarga posterior Se puede instalar un codo de 90 justo arriba de la campana Salida a trav s del muro Salida a trav s del techo A Boquilla de descarga al techo B Ducto redondo de 8 20 32 cm A Boquilla de descarga a la pared B Ducto redondo de 8 20 32 cm C Codo de 90 26 Instalaci n 82 min de apertura para el ducto Montaje del soporte de la cubierta del conducto VETERE Dela linea horizontal trazada en la secci n anterior dibuje una l nea horizontal paralela como se muestra abajo Centre el soporte en la l nea horizontal superior y alin ela con la l nea central como se describe en el siguiente dibujo L nea de centro Estafa p ductos z Soporte de 7 E x t 4 montaje 1 x 6 min L nea de centro de instalaci n a E _ Lines Horizontal Montaje de la campana n ADVERTENCIA Se necesitan 2 personas para levantar y Se ale la ubicaci n de los orificios para los tornillos en la pared posicionar la campana en los pernos tornillos de montaje Coloque la plantilla sobre la pared a lo largo de la linea horizontal IMPORTANTE Aseg rese de que dichos orificios sean nivelados Aseg rese de que la plantilla est nivelada y centrada con la l nea y centrados con la l nea central de centro Taladre los orificios gu a de s en las posicione
8. de que la instalaci n el ctrica es adecuada y en conformidad con National Electrical Code ANSI NFPA 70 ultima edici n o CSA Standards C22 1 94 Canadian Electrical Code Parte 1 y C22 2 No 0 M91 ultima edici n y toda la normativa y las ordenanzas locales Sila normativa lo permite y se utiliza un cable de toma a tierra i dependiente se recomienda que un electricista cualificado determine si la difracci n de onda de tierra es la adecuada No ubique la toma a tierra en una tuber a de gas e Sino esta seguro de que la campana est correctamente conectada a tierra consulte a un electricista cualificado e No coloque ning n fusible en el circuito neutral o con vuelta por tierra IMPORTANTE Guarde las instrucciones de instalaci n para su uso por parte del inspector de electricidad Lacampana debe est conectada nicamente con hilo de cobre Lacampana debe estar conectada directamente al desconectador con fusible O disyuntor mediante canal met lico de cables el ctricos e Los tama os de cable deben cumplir los requisitos de la National Electrical Code ANSI NFPA 70 ltima edici n o CSA Standards C22 1 94 Canadian Electrical Code Parte 1 y C22 2 No 0 M91 ultima edici n y toda la normativa y las ordenanzas locales e Es preciso colocar un conector de canal de cables enumerado en U L o C S A en cada extremo del canal de cables de fuente de alimentaci n En la campana y en la caja de conexiones Se
9. installer la hotte 14 Outils et pi ces Pi ces fournies 5 nine cede eere ti t PEE ede eir Pants 15 Pi ces non fournies 15 Dimensions et D gagement cceeceeeseeeeceneeeneeseeeeeceaeeeaeeeaeeeaeeeaeenatenaees 15 Exigences d emplacement 16 Exigences concernant l vacuation 16 Iristructions d Installation cocoa 17 Raccordement lectrique 19 Achever l installation et v rifier le fonctionnement 19 Utilisation d lah ft 5 82 0 reote acia 20 Entretien de la hotte de cuisini re 20 A NN 21 APPROUV COMME APPAREIL DOMESTIQUE POUR UNE UTILISATION R SIDENTIELLE SEULEMENT LISEZ CES INSTRUCTIONS ET CONSERVEZ LES VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE COMMENCER L INSTALLATION DE L APPAREIL DOIT RESPECTER TOUS LES CODES EN VIGUEUR IMPORTANT Conservez ces instructions afin de pouvoir les remettre l inspecteur lectricien de votre r gion INSTALLATEUR Veuillez laisser ces instructions avec l appareil pour le propri taire PROPRI TAIRE Veuillez conserver ces instructions pour pouvoir vous y r f rer plus tard Avertissement de s curit Coupez l alimentation du circuit dans le panneau lectrique et verrouillez le panneau avant de raccorder les fils de cet appareil Exigence 120 V c a 60 Hz circuit de d rivation de 15 V c a 20 Hz de 15 ou 20 A 12 LIRE ET CONSERVER CES INSTRUCTIONS Avis de s curit important ATTENTION
10. les conducteurs blancs A l aide de connecteurs de fils homologation UL 9 l aide des connecteurs de fils homologation UL connecter le conducteur de liaison la terre vert ou nu du c ble d alimentation du domicile au conducteur vert jaune de liaison la terre D dans le boitier de connexion 10 Installer le couvercle du boitier de connexion 11 Inspecter chaque lampe v rifier que chaque lampe est bie ins r e dans sa douille 12 Reconnecter la source de courant lectrique 19 2 Achever l installation et v rifier le fonctionnement 1 Installez des filtres graisse Voir la section Entretien de la hotte Contr ler le fonctionnement du ventilateur de la hotte et des lampes Voir la section Utilisation de la hotte A Lampes halog ne B Interrupteur de lampe halog ne C S lecteur de commande du ventilateur D Poign es du filtre graisse E Filtre graisse Si la hotte ne fonctionne pas d terminer si un disjoncteur s est ouvert ou si un fusible du domicile est grill D connecter la source de courant lectrique du circuit et v rifier que le c blage est correct REMARQUE Pour pouvoir tirer le plus grand parti de la nouvellehotte de cuisini re lire la section Utilisation de la hotte Utilisation de la hotte La hotte de cuisini re est con ue pour extraire fum e vapeurs de cuisson et odeurs de la zone de la table de cuisson Pour obt
11. pared falsa cart n yeso marque la ubicaci n de los orificios para los tornillos Y retire la plantilla e Remueva corte lo suficiente de pared para posicionar 2 postes verticales en la ubicaci n de los orificios referenciados en el punto anterior con ayuda de la plantilla Instale dos soportes horizontales de por lo menos 4 x 2 entre dos postes de la pared en donde deber n ir posicionados los orificios inferiores Use abrazaderas bridas detr s de ambos lados del soporte para sujetarlo hacia la pared e Reinstale la pared falsa cart n yeso resane y termine IMPORTANTE El armaz n debe ser capaz de sostener 100 Ib 27 Instalaci n de la campana Instalaci n de las cubiertas de ductos La campana se sujeta a la pared por 2 tornillos de montaje en el 1 Posicione el ducto inferior sobre la campana soporte de madera 2 Posicione el ducto superior en la estafa de cubreductos 1 Con la ayuda de al menos 2 personas coloque la campana 3 Asegure el ducto superior con 2 tornillos de 4 2 x 8 mm extractora sobre el soporte de madera Aseg rese que los tornillos de montaje coinciden con las ranuras de la parte posterior de la campana extractora C 4 Asegure los ductos inferiores a la campana usando 2 tornillos de A Tornillos de instalaci n 2 5 x 45 mm 42x8mm B Ranuras de montaje C Tornillos inferiores de instalaci n 2 5 x 45 mm 2 Empuje la campana hacia la parte delgada de los or
12. pueden obtener copias de los est ndares enumerados en National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Antes de instalar la campana 1 Para obtener una circulaci n del flujo de aire m s eficaz utilice un tubo de tramo recto o el menor n mero posible de tubos acodados PRECAUCI N el conducto de ventilaci n solamente debe tener salida hacia la parte exterior del edificio 2 Para realizar la instalaci n se necesitan al menos dos personas 3 La campana se ajusta mediante material adecuados para la mayor a de superficies consulte a un instalador cualificado para comprobar si quedan perfectamente ajustados al armario o a la pared No emplee tubos flexibles Las instalaciones en CONDICIONES CLIM TICAS FR AS deben tener instalado un regulador de contratiro adicional para minimizar el flujo de aire inverso y una rotura t rmica no met lica para minimizar la conducci n de temperaturas externas como parte de los tubos El regulador debe encontrarse en la parte de aire fr o de la rotura t rmica La rotura debe estar los m s cerca posible al lugar donde los tubos entran en la parte caliente de la casa 6 Aire limpio Las normativas locales para edificios pueden requerir el uso de sistemas de aire limpio cuando se utilizan sistemas de ventilaci n mediante tubos superiores al CFM especificado de movimiento de
13. sockets 3 Check operation of the range hood blower and lights See the Range Hood Use section Failure to do so can result in death or electrical shock Disconnect power Locate junction box of the range hood Remove terminal box cover and set aside Remove knockout from terminal box and install a UL listed or CSA approved Y strain relief 5 Place the range hood near its mounting position and run the power supply cable through the strain relief into terminal box enough to make connection 6 Tighten the strain relief screws Bom A Halogen lamps D Filter handles B Lamps knob E Grease filter C Blower knob 4 If range hood does not operate check to see whether a circuit A Electric box cover B Cover installation screws breaker has tripped or a household fuse has blown C Knockout Disconnect power supply and check that the wiring is correct NOTE To get the most efficient use from your new range hood read the Range Hood Use section A White wires D Green Bare or Yellow Green wires B Black wires E Home power supply C UL listed wire connectors F UL listed or CSA approved Y strain relief 7 Use UL listed wire connectors and connect black wires B together 8 Use UL listed wire connectors and connect white wires A together 9 Connect green or bare ground wire from home power supply to the green yellow ground wire D in terminal box using UL listed wire connec
14. 2 cm cet emplacement 4 Tirer suffisamment de cable d alimentation travers le mur pour permettre un raccordement facile jusqu la boite de connexion 5 Installer le raccord de transition pour conduit carr de 8 20 3 cm l aide de 4 vis de 3 5 x 9 5 mm 17 Installation de la hotte Installation des cache conduits 1 Pousser la section inf rieure vers le bas sur la hotte 1 A deux personnes au moins suspendre la hotte aux 2 crochets de 2 Soulever la section sup rieure vers le plafond montage travers les encoches de montage l arri re de la 3 Positionner la section sup rieure deL cache conduit sur le support hotte de montage 4 Installer l ensemble avec 2 vis de 4 2 x 8 mm C A Vis de montage 2 5 x 45 mm B Encoches de montage C Vis de montage inf rieures 2 5 x 45 mm 2 Pousser la hotte dans les fentes troites aligner le bas de la hotte sur la ligne horizontale tablir l aplomb de la hotte et serrer les 2 5 Fixer le bas du conduit avec 2 vis de 4 2 x 8 mm vis de montage 3 Marquer les emplacements des 2 trous de montage inf rieurs Percer des avant trous de 7s si les trous sont situ s dans du bois Si les trous ne sont pas situ s dans du bois ter la hotte et percer deux avant trous de et ins rer des chevilles d ancrage mural de 10 x 50 mm Remonter la hotte en tablir l aplomb et serrer les vis sup rieures Installer les 2 vis de 6 x 80 mm dans les chevilles de montag
15. AE et le code des autorit s de votre r gion E Au moment de couper ou de percer un mur ou un plafond assurez vous de ne pas endommager la filerie lectrique ou tout autre acc s un service publique F Il faut toujours vacuer l ext rieur les syst mes conduit ATTENTION Pour r duire les risques d incendie et vacuer l air correctement assurez vous que le conduit m ne l ext rieur il ne faut pas vacuer l air dans l espace entre les murs dans les plafonds dans les greniers les vides sanitaires ou les garages AVERTISSEMENT POUR R DUIRE DES RISQUES D INCENDIE UTILISEZ UNIQUEMENT DES CONDUITS EN M TAL Installez cette hotte en respectant toutes les exigences mention n es AVERTISSEMENT Pour r duire les risques d incendie et de choc lectrique n utili sez pas cette hotte avec un contr leur de vitesse semi conduc teurs AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE GRAISSE SUR LES CUISINI RES a Ne laissez jamais la cuisini re sans surveillance lorsqu elle est r gl e une haute temp rature Les d bordements par bouillonnement causent de la fum e et des d bordements de gras qui peuvent s enflammer Faites chauffer l huile lentement une temp rature basse ou moyenne b Faites toujours fonctionner la hotte lorsque vous utilisez la cuisini re une haute temp rature ou que vous faites flamber des aliments P ex cr pes Suzette cerises jubil es boeuf au poivre
16. OS b NUNCA TOME UNA SART N EN LLAMAS podr a sufrir quemaduras c NO UTILICE AGUA incluidas bayetas o toallas h medas ya que se producir a una violenta explosi n de vapor d Utilice un extintor S LO si 1 Sabe que dispone de un extintor de la clase ABC y conoce su funcionamiento 2 El fuego es peque o y se encuentra en la misma zona donde se inici 3 Ha llamado a los bomberos 4 Puede luchar contra el fuego teniendo una salida a su espalda Basado en Consejos de seguridad para fuegos de cocina publica do por el NFPA Asociaci n nacional de protecci n contra incendios FUNCIONAMIENTO Coloque siempre las rejillas y los filtros de seguridad en su lugar cor respondiente Sin estos componentes los ventiladores en funciona miento podr an atrapar su pelo sus dedos o su ropa El fabricante declina toda responsabilidad en caso de fallo de cum plimiento de las instrucciones aqu facilitadas para la instalaci n el mantenimiento y el uso adecuado del producto El fabricante declina adem s toda responsabilidad por da os ocasionados por negligencia y la garant a de la unidad queda cancelada autom ticamente como consecuencia de un mantenimiento incorrecto 23 Requisitos el ctricos y de instalaci n Requisitos El ctricos IMPORTANTE Cumpla todas las normativas y ordenanzas gubernamentales Es responsabilidad del cliente e Ponerse en contacto con un instalador el ctrico cualificado Asegurarse
17. RTO Esta garant a se extiende al comprador original de productos adquiridos para uso residencial en Norte Am rica incluyendo Estados Unidos Guam Puerto Rico Islas V rgenes de USA y Canad Esta garant a no es transferible y aplica solamente al comprador original y no se extiende a propietarios subsecuentes del producto Esta garant a se expresa en lugar de otras garant as expresadas o implicadas incluyendo pero no limitada a ninguna garant a implicada de comercializaci n o adaptada para prop sitos particulares y cualquier otra obligaci n por parte de Elica North America considerando sin embargo que si la negaci n de garant as impl citas es inefectiva bajo la ley aplicable la duraci n de cualquier garant a impl cita ser limitada a dos 2 a os desde la fecha original de compra o por el periodo necesario como sea requerido por la ley aplicable Esta garant a no cubre cualquier da o especial incidental y o consecuente ni p rdidas de ganancias sufridas por el comprador original sus clientes y o usuarios del producto A QUIEN CONTACTAR Para obtener Servicio bajo Garant a o para cualquier pregunta relacionada a Servicio Favor de llamar Servicio Autorizado de Elica North America al 888 732 8018 O escribiendo a Elica North America Atenci n a Servicio a Clientes 6658 156th Avenue SE Bellevue WA 98006 USA infoamericas elica com 31 LIB0099968 Impreso en M xico
18. S et ELN142SS Dual Moteur du ventilateur 1200CFM seulement ci dessus les tables de cuisson nominale sup rieure 65 000 BTU 14 Outils et pi ces Enlever l emballage ATTENTION Enlever d licatement le carton Porter des gants pour se prot ger des bords coupants AVERTISSEMENT Enlever le film de protection recouvrant le produit avant de commenc er l op ration Pi ces fournies Auvent de hotte avec ventilateur et lampes install s e Raccord de transition du 8 e Cache conduit Filtre s graisse Sac de mat riel avec Guide et l utilisation d installation Bride de support du cache conduit Adaptateur T20 TORXGT 6 Vis de montage de 5 x 45 mm 4 Vis de montage de 3 5 x 9 5 mm 4 Vis de montage de 4 2 x 8 mm 2 Pi ces d ancrage mural de 8 x 40 mm 4 Pi ces d ancrage mural de 10 x 50 mm Pi ces n cessaires e C ble d alimentation lectrique du domicile Serre c ble de Y 12 7 mm homologation UL ou CSA 3 connecteurs de fils homologu s UL 1 bouche de d charge d charge travers le mur ou travers le toit e Circuit d vacuation m tallique de 8 Outils n cessaires Niveau e Perceuse dans foret du 174 3 2 cm Ye 3 2 mm et e 7 9 mm Crayon Pince d nuder ou couteau utilitaire M tre ruban ou r gle Pince e Pistolet calfeutrage et compos de calfeutrage r sistant aux intemp ries Brides de conduit Scie sauteuse ou scie
19. Sans la pr sence de ces derniers les parties aspirantes pourraient attirer les cheveux les doigts ou les v tements Le fabricant d cline toute responsabilit si les informations d taill es dans ce manuel pour l installation l entretien et l utilisation ad quate du produit ne sont pas observ es Le fabriquant d cline en outre toute responsabilit pour d ventuelles blessures dues des n gligences en outre la garantie de l appareil sera annul e suite des conditions d entretien inappropri es Cet appareil est fabriqu pour un usage interne Ne pas utiliser cet appareil l ext rieur 13 Exigences lectriques et d installation Sp cifications lectriques IMPORTANT Respectez tous les codes et les ordonnances en vigueur Le client a la responsabilit de Contacter un lectricien installateur V rifier que l installation lectrique est ad quate et conforme avec le Code national de l lectricit ANSI NFPA 70 la plus r cente dition ou les normes C22 1 94 Code canadien de l lectricit Partie 1 et C22 2 No 0 M91 La plus r cente dition de la CSA ainsi que tous les codes et les ordonnances de votre r gion Si le code le permet et que vous utilisez un fil de mise la terre distinct il est recommand de faire v rifier le chemin du fil par un lectricien Ne pas mettre l appareil la terre sur une conduite de gaz Consultez un lectricien qualifi si vous n tes pas certain que la
20. UTILISER CET APPAREIL DES FINS DE VENTILATION G N RALE SEULEMENT NE PAS UTILISER CET APPAREIL POUR VACUER DES MAT RIAUX OU DES VAPEURS DANGEREUX OU EXPLOSIFS AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE ET DE BLESSURE RESPECTER LES DIRECTIVES SUIVANTES A Utiliser cet appareil uniquement aux fins pr vues par le fabricant Si vous avez des questions propos de l appareil communiquez avec le fabricant B Avantde faire l entretien de l appareil ou de le nettoyer coupez l alimentation dans le panneau lectrique et verrouillez le panneau en bloquant le dispositif permettant d emp cher d activer l alimentation accidentellement S il n est pas possible de verrouiller l acc s au panneau fixez une tiquette tr s voyante au panneau lectrique C Une personne qualifi e doit effectuer l installation et le c blage des fils lectriques en conformit avec tous les codes et toutes les normes y compris la cote de r sistance au feu D Il est important de pr voir suffisamment d air pour assurer une bonne combustion de l quipement de chauffe et l vacuation ad quates des gaz par le conduit de chemin afin de pr venir les refoulements d air Respectez les directives et les normes de s curit des fabricants de l quipement de chauffage comme celles publi es par la National Fire Protection Association NFPA la American Society for Heating Refri eration and Air Conditioning Engineers ASHR
21. Use Care and Installation Guide Guide d utilisation d entretien et d installation Gu a de instalaci n uso y mantenimiento READ AND SAVE THESE INSTRUCTIONS LISEZ CES INSTRUCTIONS ET CONSERVEZ LES LEA Y GUARDE ESTAS INSTRUCCIONES LIB0099968A 07 14 EN Contents FR Sommaire ES Contenido page 2 page 12 p gina 22 English Contents Important safety Notice ce eee ice ee diei 3 Electrical amp Installation requirements o ooooonocccnnnccncoccconocononnononncconnnnnnnnnnno 4 Before installing the hood essssseeeeeeeeeneneeee nennen 4 Listiof Materials nente en o OR EAR e tenet ine ean eras 5 Parts Supplied PE 5 Parts voL supplied copii te ts ee etn Hr ER SEXE REA Med EURE NT 5 Product DIMENSIONS iki o ore meer cae tere creer eri e oreet ane 5 LOCATON Roque mica aia 6 Venting Requirements nennen nenne 6 Venting methods a ee te te me t re ea 6 Installation iro tci nein eere Er eene los RR FERES 7 Make electrical connection 9 Complete Installation and check operation 9 Range liood ise nett aaa its 10 UN na crt tra ey Ce er e Pat 10 Warranty ceti tee ie Eb enter et Te ads ise 11 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING INSTALLATION MUST COMPLY WITH ALL LOCAL CODES IMPORTANT Save these Instructio
22. a SMOTHER FLAMES with a close fitting lid cookie sheet or other metal tray then turn off the gas burner or the electric element BE CAREFUL TO PREVENT BURNS If the flames do not go ou immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN you may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA OPERATION a Always leave safety grills and filters in place Without these com ponents operating blowers could catch onto hair fingers and loose clothing The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance Electrical amp Installation requirements Electrical requirements IMPORTANT Observe all governing codes and ordinances It is the customer s responsibility e To contact a qualified electrical installer e To assure that the electrical inst
23. a corriente 2 Utilice un destornillador de punta plana y suavemente retire la cubierta de la l mpara 3 Retire la l mpara y reempl cela por una l mpara hal gena de 120 volts 40 watt m ximo con base G 9 4 Coloque nuevamente la cubierta de la l mpara 5 Conecte nuevamente la corriente Limpieza Superficies exteriores Para evitar el dafio en las superficies externas no use estropajos de acero ni jabonosos Siempre s quelo con un pafio para evitar manchas de agua Seque siempre con un pafio seco para evitar marcas de agua m Limpiador de acero inoxidable o Polish m Detergente l quido y agua m L mpielo con un pa o suave h medo o una esponja no abrasiva enju guelo con agua limpia y s quelo con un pa o Filtros met licos y Graseras 1 Use ambas manos para retirar los filtros 2 Sujete las manijas de los filtros jale hacia el frente de la campana y empuje hacia abajo para retirarlo Repita el proceso para cada filtro A Filtro de grasa 3 Remueva las graseras A Graseras 4 Lave los filtros met licos y las graseras en lavaplatos o con soluci n jabonosa caliente 5 Vuelva a colocar las graseras 6 Reinstale los filtros SS F1 A Filtro de grasa 30 GARANT A ELICA Norte Am rica GARANTIA LIMITADA A DOS ANOS PARA OBTENER SERVICIO DENTRO DE GARANTIA El propietario debe presentar su recibo original de la compra Guarde
24. aire El CFM especificado var a de una zona a otra Para conocer los requisitos espec ficos de su zona consulte a un profesional de HVAC NOTA Utilice el modelo de campana ELN130SS Motor Unitario 600CFM s lo en superficies de cocinado que generen un m ximo de 65 000 Btus o BR Utilice los modelo de campana ELN136SS y ELN142SS Motor Dual 1200CFM s lo en superficies de cocinado que generen m s de 65 000 Btus 24 Lista de Materiales Retirar del empaque CUIDADO Remueva el empaque con cuidado utilice guantes para protegerse de los filos cortantes ADVERTENCIA Retire la cubierta protectora del producto antes de ponerlo en funciona miento Partes suministradas Cuerpo de la campana con motor y l mparas ya instaladas Transici n met lica de 8 Cubreductos Filtros de grasa met licos Bolsa pl stica con Manual de instalaci n y uso Estafa de cubreductos Adaptador TORX t T20 6 Tornillos de instalaci n de 5 x 45 mm 4 Tornillos de instalaci n de 3 5 x 9 5 mm 4 Tornillos de instalaci n de 4 2 x 8 mm 2 Taquetes de 8 x 40 mm 4 Taquetes de 10 x 50 mm Partes necesarias Cable de alimentaci n Pasacables de Y 12 7 mm aprobado por UL CSA 3 conectores de cables aprobados por UL 1 boquilla para pared o techo Sistema de ventilaci n met lico redondo de 8 Herramientas Materiales necesarios Nivel Taladro con brocas de 1 3 2 cm 7s 3 2 mm y Ys 7 9 mm L piz
25. allation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances e f codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a qualified electrician if you are not sure range hood is properly grounded Do not have a fuse in the neutral or ground circuit IMPORTANT Save Installation Instructions for electrical inspector s use e The range hood must be connected with copper wire only The range hood should be connected directly to the fused disconnect Or circuit breaker box through metal electrical conduit Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances e AULL or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachu setts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Before installing th
26. ampana esta dise ada para remover humo vapores de cocina y olores del rea de cocina Para mejores resultados encienda la campana antes de cocinar y permita que opere algunos minutos despu s de haber terminado de cocinar para dispersar todo el humo y olores de la cocina Los controles est n localizados en la parte central de la campana Miu 7Q OFF OFF e Low 1 A B A Control de l mparas hal genas B Control de velocidades del motor Funcionamiento de las l mparas 1 Gire el control a la posici n LOW para encender las luces 2 Gire el control a la posici n HI para encender las luces a su m ximo nivel 3 Gire el control a la posici n OFF para apagar las luces Funcionamiento del motor 1 Gire el control a la posici n 1 para encender la campana 2 Gire el control a la velocidad deseada 3 Gire el control a la posici n HI para obtener la m xima potencia de su campana 4 Gire el control a la posici n OFF para apagar su campana Cuidado de su campana Reemplace la l mpara hal gena Apague la campana y permita que las l mparas se enfrien Para impedir el dafio o deterioro en la vida til de la l mpara evite manejar la l mpara directamente con los dedos Reemplace la l mpara utili zando un pafiuelo o usando guantes para manejar la l mpara Si las l mparas nuevas no funcionan aseg rese de que est n colo cadas correctamente antes de llamar al servicio 1 Desconecte l
27. campana cerca de su ubicaci n y haga pasar el cable de alimentaci n atrav s del precorte al interior de la caja el ctrica 6 Apriete la tuerca del pasacables Bom E D A L mparas hal genas D Sujetadores del filtro de grasa B Control de l mparas E Filtro de grasa C Control de velocidades 3 Si su campana no funciona compruebe si el interruptor est SUR desconectado o se han fundido los fusibles Desconecte el A Tapa de la caja el ctrica md ERA B Tornillos de instalaci n suministro el ctrico Compruebe si el cableado es correcto C Precortes NOTA Para obtener el uso m s eficiente de su campana lea la sec ci n Uso de la campana A Cables blancos D Cable verde desnudo 6 verde B Cables negros amarillos C Conector de cables E Cable de alimentaci n el ctrica aprobado por UL F Sujeta cable de Y aprobado por UL CSA 7 Utilice conectores aprobados por UL y conecte los cables negros B 8 Utilice conectores aprobados por UL y conecte los cables blancos A 9 Conecte el alambre verde o desnudo de puesta a tierra del suministro de energ a dom stico al alambre amarillo verde de puesta a tierra D en la caja de terminales usando conectores de alambres que est n en la lista de UL 10 Instale la cubierta de la caja el ctrica 11 Verifique que las l mparas se encuentren bien colocadas 12 Reconecte la corriente el ctrica 29 Uso de la campana Esta c
28. e inserted correctly before calling service 1 Disconnect power 2 Use aflat blade screwdriver and gently pry the light cover loose 3 Remove the lamp and replace with a 120 volt 40 watt maximum halogen lamp made for a G 9 base 4 Replace the light cover Reconnect power Turn the light switch to the OFF position to turn the range hood lights Off oa Cleaning Exterior surfaces To avoid damage to the exterior surface do not use steel wool or soap filled scouring pads Rub in direction of the grain line to avoid scratching the surface Always wipe dry to avoid water marks m Stainless Steel Cleaner and Polish m Mild liquid detergent and water m Wipe with damp soft cloth or nonabrasive sponge then rinse with clean water and wipe dry Metal Filters and Drip Trays 1 Use2 hands to remove filters 2 Grasp filter handles pull toward the front of range hood and pull down on the rear handle to remove Repeat for each filter SS MT A Grease filter 3 Remove grease drip tray iC A Drip tray 4 Wash metal filters and grease trays as needed in dishwasher or hot detergent solution to clean Replace grease drip tray Reinstall filters grasp filter handles and place front edge of filter into the hood Push up on the back handle and set rear of filter into the drip tray to secure Repeat for each filter own A Grease filter 10 WARRANTY ELICA Nort
29. e a altura o garajes ADVERTENCIA PARA REDUCIR EL RIESGO DE FUEGO UTILICE SOLAMENTE TUBOS MET LICOS Instale esta campana de acuerdo con los requisitos especificados ADVERTENCIA Para reducir el riesgo de fuego o descarga el ctrica no utilice esta campana con ning n dispositivo externo en estado s lido para el control de la velocidad ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO OCASIONADO POR GRASA a No deje nunca ninguna unidad externa desatendida y con valores de fuego altos La cocci n puede causar humo o reboses de grasa que pueden prender fuego Caliente el aceite a fuego lento o medio b Encienda siempre la campana cuando cocine a una temperatura alta o cuando realice flameados Por ejemplo crepes Suzette cerezas flameadas ternera a la pimienta flameada c Limpie con frecuencia los ventiladores No permita que la grasa se acumule en el ventilador o filtro d Utilice un tama o de sart n adecuado Utilice siempre piezas de bater a de cocina adecuadas al tamafio del elemento de superficie ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES PERSONALES EN CASO DE FUEGO OCASIONADO POR GRASA TENGA EN CUEN TA LO SIGUIENTE a EXTINGA LAS LLAMAS con una tapa ajustada una l mina para hacer galletas u otro tipo de bandeja met lica y apague el que mador de gas o elemento el ctrico TENGA CUIDADO PARA EVITAR QUEMADURAS Si las llamas no se extinguen inmediatamente DESALOJE EL LUGAR Y LLAME A LOS BOMBER
30. e hood 1 For the most efficient air flow exhaust use a straight run or as few elbows as possible CAUTION Vent unit to outside of building only 2 Atleast two people are necessary for installation 3 Fittings material is provided to secure the hood to most types of walls ceilings consult a Qualified Installer check if they perfectly fit with your cabinet wall Do not use flex ducting COLD WEATHER installations should have an additional back draft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork The damper should be on the cold air side of the thermal break The break should be as close as possible to where the ducting enters the heated portion of the house Make Up air Local building codes may require the use of make up air systems when using ducted ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area NOTE Use the Range Hood model ELN130SS Single Blower Motor 600CFM only above a cooktop with a maximum of 65 000 Btus as Use the Range Hoods models ELN136SS and ELN142SS Dual Blower Motor 1200CFM above cooktops rated higher than 65 000 Btus List of Materials Removing the packaging CAUTION Remove carton carefully wear gloves to protect against sharp edges WARNING
31. e inf rieures et serrer C 4 Connecter le circuit d vacuation la hotte Utiliser des brides de serrage pour sceller chaque connexion 5 Sivotre installation utilise le cache conduit facultatif le monter sur le haut de la hotte en suivant les instructions fournies avec le cache conduit 18 Raccordement lectrique AVERTISSEMENT Risque de choc lectrique D connecter la source de courant lectrique avant l entretien Replacer pi ces et panneaux avant de faire la remise en marche Le non respect de ces instructions peut causer un d c s ou un choc lectrique D connecter la source de courant lectrique Placer le boitier de connexion Retirer le couvercle du boitier de connexion Oter l opercule arrachable du boitier de connexion et installer un serre c ble de homologation UL ou CSA Acheminer le cordon d alimentation du domicile travers le PONS serre cable dans le boitier de connexion Serrer la vis du serre c ble A Couvercle du boitier de connexion B Installation vis C Opercule arrachable A Conducteurs blancs B Conducteurs noires C Connecteurs de fils homologation UL D Conducteurs verts ou nus ou vert jaune de liaison la terre E Cable d alimentation lectrique du domicile F Serre cable du 77 homologation UL ou CSA 7 Connecter ensemble les conducteurs noirs B avec des connecteurs de fils homologation UL 8 Connecter ensemble
32. enir les meilleurs r sultats mettre le ventilateur de la hotte en marche avant d entreprendre une cuisson et laisser le ventilateur fonctionner pendant plusieurs minutes apr s l ach vement d une cuisson pour pouvoir vacuer de la cuisine toute trace d odeur de cuisson vapeur ou fum e Les commandes de la hotte sont situ es sur le c t central de la hotte vli WF OFF OFF LOW 1 B A Commutateur de lampe B Commutateur de ventilateur Pour faire fonctionner les lampes 1 Tournez le commutateur d clairage sur la position LOW pour teindre les lumi res 2 Placer le commutateur d clairage la position HI haut pour allumer la lumi re au maximum niveau 3 Placer le commutateur d clairage la position OFF arr t pour teindre les lumi res Utilisation du ventilateur 1 Tournez le bouton du ventilateur 1 pour allumer la hotte 2 Tournez le commutateur du ventilateur la position de vitesse d sir 3 Tournez le commutateur du ventilateur la position HI pour mettre la hotte Haut 4 Tournez le commutateur du ventilateur la position OFF pour teindre le ventilateur de la hotte Entretien de la hotte de cuisiniere Remplacement d une lampe halog ne Interrompre l alimentation de la hotte attendre le refroidissement de la lampe halog ne Pour viter d endommager ou de r duire la long vit de l ampoule neuve ne pas toucher l ampoule avec les
33. flamb C Nettoyez les h lices de ventilation fr quemment Il ne faut pas que la graisse s accumule sur les filres ou les h lices d Utilisez le bon format de casserole Utilisez toujours un chaudron de taille appropri l l ment de la cuisini re AVERTISSEMENT POUR VITER DE BLESSER QUELQU UN LORS D UN INCEND IE DE GRAISSE SUR LA CUISINI RE SUIVRE LES CONSEILS SUIVANTS a TOUFFER LES FLAMMES avec un couvercle aux dimensions de la taque de cuisson une t le biscuit ou tout autre plateau m tallique puis couper le gaz ou l alimentation lectrique de la cuisini re FAIRE ATTENTION A NE PAS SE BR LER Si les flammes ne s teignent pas imm diatement QUITTER LA PI CE ET APPELER LES POMPIERS b NE JAMAIS PRENDRE EN MAIN UNE CASSEROLE EN FEU vous pourriez vous blesser c NE PAS UTILISER D EAU y compris les essuies de vaisselle ou les serviettes humides une violente explosion due la vapeur form e pourrait survenir d Utiliser un extincteur SEULEMENT si 1 Vous tes s r d avoir un extincteur de classe ABC que vous savez utiliser 2 Le feu est petit et confin la zone ou il s est form 3 Les pompiers ont t appel s 4 Vous pouvez lutter contre le feu avec une sortie derri re vous a Recommandations tir es des conseils de s curit en cas d incendie de cuisine publi s par la NFPA MODE OP RATOIRE a Toujours laisser les grilles de s curit et les filtres leur place
34. h America TWO YEARS LIMITED WARRANTY TO OBTAIN SERVICE UNDER WARRANTY Owner must present proof of original purchase date Please keep a copy of your dated proof of purchase sales slip in order to obtain service under warranty PARTS AND SERVICE WARRANTY For the period of two 2 years from the date of the original purchase Elica will provide free of charge non consumable parts or components that failed due to manufacturing defects During these two 2 years limited warranty Elica will also provide free of charge all labor and in home service to replace any defective parts WHAT IS NOT COVERED Damage or failure to the product caused by accident or act of God such as flood fire or earthquake Damage or failure caused by modification of the product or use of non genuine parts Damage or failure to the product caused during delivery handling or installation Damage or failure to the product caused by operator abuse Damage or failure to the product caused by dwelling fuse replacement or resetting of circuit breakers Damage or failure caused by use of product in a commercial application Service trips to dwelling to provide use or installation guidance Light bulbs metal or carbon filters and any other consumable part Normal wear of finish Wear to finish due to operator abuse improper maintenance use of corrosive or abrasive cleaning products pads and oven cleaner products WHO IS COVERED This warranty is extended t
35. hed by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities E When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities F Ducted systems must always be vented to the outdoors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCT WORK Install this hood in accordance with all requirements specified WARNING To reduce the risk of fire or electric shock do not use this hood with any external solid state speed control device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i E Crepes suzette cherries jubilee peppercorn beef flambe c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING
36. hotte est mise la terre correctement N installez pas un fusible dans le circuit neutre ou le circuit de mise la terre IMPORTANT Conservez ces instructions afin de pouvoir les remettre l inspec teur lectricien La hotte doit tre c bl e uniquement l aide de fils de cuivre ll faut raccorder la hotte directement une boite fusible ou un disjoncteur par l entremise d une canalisation lectrique en m tal Le calibre de fil doit tre conforme aux exigences du Code national de l lectricit ANSI NFPA 70 La plus r cente dition ou les normes C22 1 94 Code canadien de l lectricit Partie 1 et C22 2 0 M91 La plus r cente dition de la CSA ainsi que tous les codes et les ordonnances de votre r gion Il faut pr voir un connecteur de canalisation approuv par l UL ou la CSA chaque extr mit de la canalisation d alimentation A la hotte et la boite de jonction Vous pouvez obtenir un exemplaire des normes indiqu es en vous adressant La National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 La CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Avant d installer la hotte 1 Pour assurer la ventilation la plus efficace possible installez la conduite en ligne droite ou avec le moins de coudes possibles ATTENTION La sortie de la conduite de ventilation doit donner sur l ext rieur 2 Deux personnes sont n ces
37. i n nec reto iode tes e re e ees 27 Conexi n eleccion ce oe Reo cete ets redes 29 Completar la instalaci n y verificar la operaci n 29 Uso de la campana 30 Cuidado de la campana 30 A M 31 APROBADO PARA APARATOS DE USO DOM STICO S LO PARA USO DOM STICO LEA Y GUARDE ESTAS INSTRUCCIONES ANTES DE CONTINUAR LEA LAS INSTRUCCIONES POR COMPLETO LA INSTALACI N DEBE CUMPLIR TODA LA NORMATI VA LOCAL IMPORTANTE Guarde estas instrucciones para su uso por parte del inspector de electricidad local INSTALADOR Entregue al propietario estas instrucciones junto con la unidad PROPIETARIO Conserve estas instrucciones para futuras consultas Advertencia de seguridad antes de realizar el cableado de este apara to desactive el circuito de energ a el ctrica en el panel de servicio y desbloquee el panel Requisito Circuito auxiliar de CA de 120 V 60 Hz 15 20A 22 LEA Y GUARDE ESTAS INSTRUCCIONES Aviso de seguridad importante PRECAUCI N S LO PARA USO DE VENTILACI N GENERAL NO UTILIZAR PARA EXPULSAR VAPORES O MATERIALES PELIGROSOS O EXPLOSIVOS ADVERTENCIA PARA REDUCIR EL RIESGO DE FUEGO DESCARGA EL CTRICA O LESIONES PERSONALES RESPETE LO SIGUIENTE A Utilice esta unidad solamente en el modo que indica el fabricante En caso de duda p ngase en contacto con el fabricante A Antes de reparar o limpiar la u
38. ificios alinee la base de la campana a la l nea horizontal nivele la campana y ajuste los tornillos de montaje 3 Marque la ubicaci n de los 2 orificios inferiores de seguridad Perfore los orificios de Y si estos estar n ubicados en madera Si no es as retire la campana y coloque 2 taquetes de 10x50mm Vuelva a colocar la campana nivele y apriete los tornillos superiores Instale 2 tornillos de 5 x 45 mm y apriete 4 Conecte el sistema de ventilaci n a la campana Utilice sujetadores para sellar las aperturas existentes 5 Si su instalaci n contempla el uso de los cubreductos m ntelos en la parte superior de la campana siguiendo las instrucciones incluidas en el kit de cubreductos 28 Conexi n el ctrica Completar la instalaci n y ADVERTENCIA Peligro de descraga el ctrica ve rificar la ope racion Antes de realizar el cableado de este aparato desactive el cir cuito de energia el ctrica en el panel de servicio 1 Instale los filtros de grasa Vea la secci n Cuidado de su Se requiere un circuito 120 VAC 15 20 A campana 2 Verifique la operaci n del motor y de las l mparas Vea la secci n Uso de la campana Desconecte la corriente el ctrica Localice la caja el ctrica en la parte superior de la campana Retire la cubierta de la caja el ctrica y col quela a un lado Retire el precorte de la caja el ctrica e instale un un sujetacables de Y aprobado por UL 5 Coloque la
39. izontal line traced in the previous section trace a horizontal parallel line as shown below Center the bracket in the top horizontal line and align it with the centerline as described in the following drawing Centerline Bracket line n Horizontal straight pencil marked line Desired installation height Mark screw holes locations in the wall IMPORTANT Check to be sure that holes locations are leveled and correctly centered by the vertical centerline Drill 6 pilot holes in the marked locations Install wall fastener anchors Drive wood 2 5 x 45 mm screws by hand into the fasteners to allow anchors to expand Remove screws Secure the bracket to the wall with wood screws and or fasteners Install framing for hood support If drywall is present mark the screw hole locations e Cut away enough drywall to expose 2 vertical studs at the holes location indicated by the template Install two horizontal supports at least 4 x 2 between two wall studs at the bottom and upper mounting holes installation location The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs Reinstalll drywall and refinish IMPORTANT Framing must be capable of supporting 100 Ibs 82 min opening for ductwork View from rear cleats 1 x 6 min Mounting Support
40. k over the 2 screws mounted to the wood support mounted to the wall C A Installation screws 2 5 x 45 mm B Mounting holes C Lower installation screws 2 5 x 45 mm Push the range hood up into the narrow slots align the bottom of the hood to the horizontal line level the hood and tighten the 2 mounting screws Mark 2 lower mounting hole locations Drill pilot holes if the holes are located into wood If holes are not located into wood remove the hood and drill two 24 pilot holes and insert 10 x 50 mm wall anchors Remount the hood level and tighten the upper screws Install 2 5 x 45 mm screws and tighten C Connect vent system to hood Seal all joints with clamps If your installation uses the optional duct cover mount it to the top of the range hood following the instructions supplied with the duct cover Mounting the duct cover 1 Position the duct cover over the mounted hood 2 Position the top of the duct over the duct mounting bracket 3 Secure the top of the duct with 2 4 2 x 8 mm assembly screws provided 4 Secure the lower duct cover to the range hood canopy using 2 4 2x 8 mm screws Make Electrical Connection Complete Installation and WARNING Electrical Shock Hazard Check Ope ration Disconnect power before servicing Replace all parts and panels before operating 1 Install grease filters See the Range Hood Care section 2 Install heat lamps into heat lamp
41. la part de Elica North America tant entendu cependant que si la r clamation pour garanties sous entendues n est pas applicable aux yeux de la loi en vigueur la dur e de toute garantie sous entendue manant de la loi doit tre limit e deux 2 ans partir de la date d achat du produit ou une p riode plus longue selon ce que dit la loi en vigueur Cette garantie ne couvre pas tout d g t particulier accidentel et ou cons cutif ni les pertes et profits charge du propri taire des ses clients et ou des utilisateurs Des produits QUI CONTACTER Pour obtenir un Service Apr s vente durant la Garantie ou pour toute autre Question li e au Service Apr s vente Appeler Elica North America Authorized Service at 888 732 8018 Ou crire Elica North America Attention Customer Service 6658 156th Avenue SE Bellevue WA 98006 USA infoamericas elica com 21 Espanol Contenido Aviso de seguridad importante 23 Requisitos el ctricos y de instalaci n 24 Lista de Materiales nnne 25 Partes suministradas muera OE 25 Partes no suministl adas eese i etit err br eo Ee eS ECHTE Eras 25 Dimensiones del producto cnn nnannnnnos 25 Requisitos de ubicaci n enne 26 Requisitos de ventilaci n 26 Iristalac
42. ments Ducted models only Vent system must terminate to the outdoors Donotterminate the vent system in an attic or other enclosed area Use metal vent only Rigid metal vent is recommended Plastic or metal foil vent is not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the most efficient and quiet operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together Use clamps to seal all joints in the vent system The vent system must have a damper If the roof or wall cap has a damper do not use the damper supplied with the range hood Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Venting Methods This canopy hood is factory set for venting through the roof or wall A 8 20 32 cm round vent system is needed for installation not includ ed NOTE Flexible vent is not recommended Flexible vent creates back pressure and air turbulence that greatly reduce performance Vent system can terminate either through the roof or wall Roof Venting Wall Venting A Roof cap A Wall cap B 8 20 32 cm round vent B 8 20 32 cm round vent C 90 elbow Installation Mounting the duct cover bracket Fixed height duct cover From the hor
43. nidad desconecte la alimentaci n en el panel de servicio y bloquee los medios de desconexi n del panel de servicio para evitar la conexi n accidental de la alimentaci n Si no es posible bloquear los medios de desconexi n del panel de servicio coloque un dispositivo de advertencia que destaque como por ejemplo una etiqueta en el panel de servicio A La instalaci n y el cableado el ctrico deben realizarlos personas calificadas de acuerdo con las normativas y los est ndares aplicables incluida la construcci n ign fuga A Es necesaria una ventilaci n suficiente para la correcta combusti n y expulsi n de gases por la salida de humos Chimenea del equipo de combusti n de carburante paa evitar el contratiro Siga las directrices de fabricantes de equipos de calefacci n y los est ndares de seguridad como los publicados por la National Fire Protection Association NFPA American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las normativas locales A Al efectuar orificios en una pared o techo no da e el cableado el ctrico y otras instalaciones ocultas A Los sistemas instalados mediante conducto deben tener ventilaci n con salida al exterior PRECAUCI N Para reducir el riesgo de fuego y conseguir una salida del aire correcta aseg rese de conducir el aire hacia el exterior No per mita que el aire se expulse en espacios situados en el interior de muros techos desvanes s tanos de pequ
44. nnement Federal Standard for Mobile Home Con struction and Safety titre 24 HUD partie 280 lorsque cette norme n est pas applicable l installation doit satisfaire aux crit res de la plus r cente dition de la norme Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A ou des codes et r glements locaux Dimensions du placard 8 21 6 cm 45 11 9 om Lam Emplacement du c blage de la maison et conduit cabinet cabinet 91 4 cm A Du bas de la 42 106 7 cm hotte la surface de cuisson ligne du centre surface de cuisson IMPORTANT Valeur minimale de la distance A 30 76 2 cm Valeur maximale sugg r e pour la distance A 36 91 4 cm from cooking surface Exigences concernant l vacuation Le syst me d vacuation doit d charger l air l ext rieur Ne pas terminer le syst me d vacuation dans un grenier ou dans un autre espace ferm Utiliser un conduit m tallique uniquement Un conduit en m tal rigide est recommand Ne pas utiliser un conduit de plastique ou en feuille m tallique La longueur du syst me d vacuation et le nombre de coudes doit tre r duit au minimum pour fournir la meilleure performance Pour un fonctionnement efficace et silencieux Ne pas utiliser plus de trois coudes 90 Veiller ce qu il y ait une section droite de conduit de 24 61 0 cm ou plus e
45. ns for the Local Electrical Inspector s use INSTALLER Please leave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this appliance Requirement 120 V AC 60 Hz 15 or 20A Branch Circuit READ AND SAVE THESE INSTRUCTIONS Important Safety Notice CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPOURS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning the unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel C Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes amp standards including fire rated construction D Sufficient air is needed for proper combustion and exhausting of gases through the flue Chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturers guideline and safety standards such as those publis
46. nstalaci n de esta campana para cocina debe ajustarse a Manufactured Home Construction Safety Standards Est ndares de seguridad y construcci n de casas fabricadas T tulo 24 CFR Parte 328 anteriormente conocidos como Federal Standard for Mobile Home Construction and Safety Est ndar federal para la seguridad y construcci n de casas rodantes T tulo 24 HUD Parte 280 o cuando dicho est ndar no sea aplicable el est ndar Manufactured Home Installation Est ndar para instalaci n en casas fabricadas de 1982 Manufactured Home Sites Communities and Setups Obras comunidades y proyectos de casas fabricadas ANSI A225 1 NFPA 501A o la ultima edici n o con los c digos locales Dimensi n del gabinete Y N 8 21 6 cm 4 11 9 cm Ubicaci n del cable de alimentaci n y del ducto gabinete gabinete 76 2 cm 36 91 4 cm 42 106 7 cm l A De la base de campana a la superficie de cocinado l nea de i centro superficie de cocinado IMPORTANTE Distancia minima A 30 76 2 cm de la superficie de cocinado Distancia m xima sugerida A 36 91 4 cm de la superficie de cocinado Los cubreductos pueden ser ajustados a diferentes alturas Requisitos de ventilaci n El sistema de ventilaci n debe terminar en el exterior No dirija la salida del sistema de ventilaci n hacia el desv n u otra rea cerrada Utilice ducto de escape de me
47. ntre deux coudes si on doit utiliser plus d un raccord coud Nepasinstaller 2 coudes ensemble Au niveau de chaque jointure du syst me d vacuation assurer l tanch it avec les brides de serrage pour conduit Le syst me d vacuation doit comporter un clapet Si la bouche de d charge murale ou par le toit comporte un clapet ne pas utiliser le clapet fourni avec la hotte de cuisini re Autour de la bouche de d charge l ext rieur par le mur ou par le toit assurer l tanch it avec un produit de calfeutrage Lataille du conduit doit tre uniforme M thodes d vacuation Un circuit d vacuation de conduits rond de 8 20 32 cm est n ces saire pour l installation non fourni REMARQUE On d conseille l emploi d un conduit flexible Un con duit flexible peut causer une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance La sortie l ext rieur du circuit d vacuation peut se faire travers le toit ou travers un mur D charge travers D charge travers A Bouche de d charge par le toit B 8 20 32 cm round vent A Bouche de d charge murale B 8 20 32 cm round vent C 90 coude 16 Instructions d installation Montage de l trier couvrent conduit Correction couvrent conduit la hauteur Dela ligne horizontale trac e dans la section pr c dente tracer une ligne horizontale parall le comme illustr ci dessous Cent
48. o the original purchaser for products purchased for ordinary residential use in North America Including the United States Guam Puerto Rico US Virgin Islands amp Canada This warranty is non transferable and applies only to the original purchaser and does not extend to subsequent owners of the product This war ranty is made expressly in lieu of all other warranties expressed or implied including but not limited to any implied warranty of merchantability or fitness for a particular purpose and all other obligations on the part of Elica North America provided however that if the disclaimer of implied warranties is ineffective under applicable law the duration of any implied warranty arising by operation of law shall be limited to two 2 years from the date of original purchase at retail or such longer period as may be required by applicable law This warranty does not cover any special incidental and or consequential damages nor loss of profits suffered by the original purchaser its cus tomers and or the users of the Products WHO TO CONTACT To obtain Service under Warranty or for any Service Related Question Please Call Elica North America Authorized Service at 888 732 8018 Or by Writing To Elica North America Attention Customer Service 6658 156th Avenue SE Bellevue WA 98006 USA infoamericas elica com 11 Fran ais Sommaire Avis de s curit important 13 Exigences lectriques et d installation 14 Avant d
49. ocation should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance Grounded electrical outlet is required See Electrical Requirements section The canopy hood is factory set for venting through the roof or wall This range hood is not available for a Non Vented recirculating Installation All openings in ceiling and wall where canopy hood will be installed must be sealed For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Con struction and Safety Title 24 HUD Part 280 or when such standard is not applicable the standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 5014 or latest edition or with local codes Cabinet Dimensions 8 21 6 cm Vent and power supply cable entry location side cabinet side cabinet 76 2 cm 36 91 4 cm A bottom of 42 106 7 cm canopy to cooking surface centerline cooking surface IMPORTANT Minimum distance A 30 76 2 cm from cooking surface Suggested maximum distance A 36 91 4 cm from cooking sur face The chimneys can be adjusted for different ceiling heights Venting Require
50. por favor una copia de su recibo de compra como prue ba para recibir el servicio dentro del periodo de garant a PARTES Y GARANTIA DE SERVICIO Por el periodo de 2 dos a os desde la fecha original de la compra Elica proveer gratuitamente partes no consumibles o componentes que hayan fallado debido a defectos de fabricaci n Durante estos 2 afios de garant a limitada Elica tambi n proveer gratuitamente todo el servicio en casa y mano de obra necesaria para reemplazar cualquier parte defectuosa QUE NO ESTA CUBIERTO Da os o fallas del producto causados por accidente o actos de Dios tales como inundaciones incendios o terremotos Da os o fallas causadas por alteraci n del producto o por el uso de partes no originales Da os o fallas del producto causados durante la entrega manejo o instalaci n Da os o fallas del producto causados por abuso del usuario Da os o fallas del producto causados por reemplazo de fusibles da ados o reseteo de interruptor de circuito Da o o fallas causados por el uso del producto en un ambiente comercial no dom stico Viajes de servicio debidos a dudas sobre el uso o instalaci n del producto Bombillas filtros de carb n o metal y cualquier otra parte consumible Desgaste normal Desgaste terminal debido a abusos del usuario mantenimiento inadecuado uso de productos toallas de limpieza corrosivos o abrasivos y por uso de limpiadores para hornos QUIEN ESTA CUBIE
51. pour le conduit 872 Vue arri re tasseaux Support de montage min txe ligne de centre del espace d installation Installation de la hotte AVERTISSEMENT Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re Placer le gabarit sur le mur le long de la ligne horizontale s assurer que le gabarit est niveau et centr sur la ligne de centre Indiquer les emplacements des vis sup rieures dans le mur IMPORTANT V rifier que tous les emplacements des trous sont niveau et correctement centr s sur la ligne de centre verticale Installer les 2 vis de montage de 5 x 45 mm Laisser un espace de Y 6 4 mm entre le mur et l arri re de la t te de vis pour faire glisser la hotte et la mettre en place 6 4mm N AVERTISSEMENT Toutes les vis de montage de la hotte doivent tre viss es dans du bois Si l on ne peut pas visser les vis de montage de la hotte dans du bois des tasseaux suppl mentaires pour accrochage mural seront peut tre n cessaires Achever la pr paration 1 D terminer et marquer toutes les lignes de d coupage n cessaires sur le mur pour le passage du circuit d vacuation Installer le syst me d vacuation avant la hotte Voir la section Exigences concernant l vacuation 2 D terminer l emplacement de passage du c ble d alimentation travers le mur 3 Percer un trou de 1 3
52. rer le support de la ligne horizontale sup rieure et l aligner avec la ligne m diane comme d crit dans le dessin suivant Ligne de bride Ligne de centre de support 7 eg Horizontale crayon droites ligne marqu e Hauteur d installation souhait e Indiquer les 2 trous pour les vis sur le mur IMPORTANT Assurez vous que les emplacements des trous sont nivel es et correctement centr par l axe vertical e Percez des trous s aux emplacements marqu s Installez des ancres de fixation murale Disque de vis bois la main dans les fixations pour permettre ancres se d velopper Retirez les vis Fixezle support au mur avec des vis bois et ou attaches Installez encadrement pour support de la hotte Si placopl tre est pr sent marquer l emplacement des trous de vis Retirer le gabarit Coupez le placopl tre assez pour exposer deux montants verticaux l endroit indiqu par les trous du gabarit Installez deux supports horizontaux au moins 4 x 2 entre les deux montants du mur trous de montage inf rleur emplacement d installation Le support horizontal doit tre align avec la salle c t des pot aux Utiliser des taquets derri re les deux c t s de l appui s curis aux montants du mur e R installer les placopl tres et de finition IMPORTANT Encadrement doit tre capable de supporter 100 Ibs Ouverture minimale
53. s marcadas Marque en la pared donde deber n ir los orificios superiores Instale los taquetes expansivos de pared IMPORTANTE Controle que dichos orificios est n nivelados y cen Con la mano inserte los tornillos para madera dentro de los trados correctamente con la l nea de centro vertical taquetes para permitir que estos se expandan Inserte a mano 2 tornillos para madera de 5 x 45 mm Deje 1 4 de Retire los tornillos distancia entre el tornillo y la pared i Y 6 4mm N Retire los filtros de grasa y monte la campana sobre los tornillos superiores NOTA Todos los tornillos deben instalarse en madera Si no hay madera en la cual instalarlos se necesitar n soportes adicionales e Coloque la estafa de cubreductos y asegure con los tornillos para el marco de pared provistos Complete la preparaci n 1 Ubique y haga todos los cortes necesarios en la pared para el sistema de ventilaci n Instale el sistema de ventilaci n antes de instalar la campana 2 Determine el lugar por donde el cable de alimentaci n correr atrav s de la pared 3 Taladre un agujero de 174 3 2 cm en esta ubicaci n 4 Pase suficiente cable de alimentaci n a trav s de la pared para que permita una f cil conexi n a la caja el ctrica 5 Instale la transici n redonda de 8 20 3 cm a la parte superior de la campana utilizando 4 tornillos de 3 5 x 9 5 mm Instalaci n del soporte para la campana Sisecuenta con
54. saires pour effectuer l installation 3 La quincaillerie fournie permet de fixer la hotte la plupart des murs et des plafonds consultez un installateur qualifi pour vous assurer que la quincaillerie fournie est adapt e votre type de mur ou d armoire 4 N utilisez pas de conduit flexible 5 Dans le cas des endroits sujets aux TEMP RATURES FROIDES il faut installer un clapet de contre tirage suppl mentaire afin de minimiser le retour d air froid et un isolant thermique non m tallique afin de minimiser la conduction de la temp rature ext rieur dans le conduit II faut placer le clapet du c t de l air froid de l isolant thermique L isolant doit tre plac le plus pr s possible de l endroit ou le conduit entre dans la partie chauff e de la maison 6 Air d appoint Le code du b timent de votre r gion peut exiger l utilisation d un syst me d air d appoint si vous utilisez un syst me de ventilation conduit dont le mouvement d air d passe un certain nombre de CFM Le nombre de pi3 min varie d une r gion l autre Consultez un professionnel de CVC pour conna tre les exigences pr cises de votre r gion ATTENTION Enlever d licatement le carton Porter des gants pour se prot ger des bords coupants AVERTISSEMENT Utilisez il mod le d Hotte ELN130SS Unique Moteur du ventilateur 600CFM seulement ci dessus les tables de cuisson nominale de 65 000 BTU maximale Utilisez les mod les d Hotte ELN136S
55. se ES A A Plateau d gouttement 4 Laver les filtre m talliques et les plateaux graisse selon le besoin au lave vaisselle ou avec une solution de d tergent chaude 5 R installer le plateau d gouttement graisse 6 R installer les filtres saisir les poign es du filtre et placer le rebord avant du filtre dans la hotte Pour bien fixer le filtre 7 pousser vers le haut sur la poign arri re et installer l arri re du filtre dans la plateau d gouttement R p ter pour chaque filtre A Filtre graisse 20 GARANTIE ELICA North America GARANTIE DE DEUX ANS POUR OBTENIR UN DEPANNAGE SOUS GARANTIE Le propri taire doit pr senter une preuve de la date d achat Garder une copie de votre preuve d achat dat e ticket de caisse de facon pouvoir b n ficier du service apr s vente sous garantie GARANTIE PIECES DE RECHANGE ET MAIN D OEUVRE Pendant une p riode de deux 2 ans partir de la date d achat Elica s engage fournir gratuitement les pi ces de rechange ou les composants autres que les recharges ayant des d fauts de fabrication Durant cette garantie de deux 2 ans Elica fournira galement gratuitement toute la main d oeuvre et le service domicile pour remplacer d ventuelles pi ces d fectueuses CE QUE LA GARANTIE NE COUVRE PAS D g t ou panne du produit caus par un accident ou un cas de force majeure tels que inondation incendie ou tremblement de terre
56. tal nicamente Se recomienda un ducto de escape de metal r gido No se recomienda ducto de escape de pl stico u hoja met lica El largo del sistema de ventilaci n y el n mero de codos se deben mantener al m nimo para proveer un funcionamiento eficaz Para obtener el funcionamiento m s eficaz y silencioso Nouse m s de 3 codos de 90 Aseg rese de que haya un m nimo de 24 61 cm de ducto de escape recto entre los codos si se utiliza m s de 1 codo No instale 2 codos lado a lado Use abrazaderas para sellar todas las juntas en el sistema de ventilaci n El sistema de ventilaci n debe tener una compuerta Si la cubierta del techo o la pared tiene una compuerta no use la compuerta provista con la campana de cocina Utilice masilla de calafateo para sellar la abertura exterior de la pared o el techo alrededor de la cubierta Eltamafio del ducto de escape debe ser uniforme M todos de ventilaci n Esta campana con escudete se ha ajustado de f brica para tener una ventilaci n a trav s del techo o de la pared Se requiere un sistema de ventilaci n redondo de 8 20 32 cm para la instalaci n no incluido NOTA No se recomienda el uso de ductos de escape flexibles Los ductos de escape flexibles crean contrapresi n y turbulencia de aire lo cual reduce el desempe o en gran medida El sistema de venti laci n debe terminar a trav s del techo o la pared Para colocar el ducto a trav s de la pared
57. tors 10 Install terminal box cover 11 Check that all light bulbs are secure in their sockets 12 Reconnect power Range hood use The range hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the center side of the range hood VA OFF OFF LOW 1 y A B A Lamps knob B Blower knob Operanni the lamps Turn the light switch to the LOW position to turn the range hood lights On 2 Turn the light switch to the HI position to turn the range hood lights at its higher intensity 3 Turn the light switch to the OFF position to turn the range hood lights Off Operaga the blower Turn the blower switch at 1 to turn the range hood on h Turn the blower switch to the desired speed position 3 Turn the blower switch to the HI position to turn the range hood on High 4 Turn the blower switch to the OFF position to turn the range hood blower Off Range hood care Replacing an Halogen Lamp Turn off the range hood and allow the halogen lamp to cool To avoid damage or decreasing the life of the new lamp do not touch lamp with bare fingers Replace lamp using tissue or wearing cotton gloves to handle lamp If new lights do not operate make sure the lamps ar