Commissioning Switching on Changing the parameters Set

image

Contents

1. 0a 10 m s de 0 a 50 C Rango MS h ssisssesssisesiiesiissriesriesriesriesrinnresnrnsnirnrrsnresnrens 0 a 99990 m h A 20 a 50 C AN 0 01 m s 0 1 C Exactitud exactitud del sistema a una temperatura de calibraci n 25 C 0 1 m s 5 del v m hasta 2 m s 0 3 m s 5 del v m mas de 2 m s 0 5 C Temperatura ambiente oococonoconaconacnnarnnarnnornnornnonanonanos 0a 50 C Temperatura almacenamiento occcccncccnocanocnconononononnnnnos 20 a 70 C a Una E ee 3 x AAA O e E E A Aprox 20 h aprox 750 mediciones de 2 minutos de duraci n o eee ee eee 12 mm 16 mm Long 150 300 mm Cpe ANGLE A 4 2 a os A 2004 108 CEE Leer antes de utilizar e Respetar la direcci n del flujo e Respetar el rango de medici n del sensor e No exceder la temperatura de almacenamiento y funcionamiento ej protejer el instrumento de medi ci n de la luz solar directa e Un uso inadecuado invalida la garant a Cambio de la pila Cuando aparece en el visualizador durante la medici n el simbolo T la pila debe cambiarse Y El instrumento se encuentra apagado 1 Retirar la tapa del compartimento para pilas 2 Sacar las pilas bater as agotadas e introducir pilas bater as 3 de AAA nuevas en el compartimento para pilas Respetar la polaridad 3 Cerrar la tapa del compartimento para pilas Funci n de auto desconexi n Si no se pulsa la tecla en aprox 5 minutos el o instrumento se apag
2. Instruction manual Multi purpose clip 2 Holder for positioning stick in duct Twist ring The lower part of the probe stem can be twisted by 90 This allows an optimum view of the display Protective cap The velocity sensor is protected by a quick twist of the bottom of the probe stem the protective cap is closed Should only be left open for the duration of the measurement Swivel head The display can always be read HB An arrow on the protective cap shows the wind direction in which the instrument was calibrated and the best readings obtained Commissioning Remove the protective film on the display Switching on Press button once pani III m s m m hx10 gt Segmenttest Current reading Changing the parameters Press button repeatedly Velocity Volume Temperature Set duct cross section m Y Keep On button pressed when switching on 1st position flashes 1 Keep On button pressed until desired digit appears Wait 2 seconds and the digit will apply The cursor then changes to the next position 2 Repeat the described procedure for all positions Thermo Anemometer testo 405 V1 en Switching off Keep button pressed for 3 seconds Technical data A Short measurement Measuring range M S oocccccccccccocccnconcnnnoncnanononnos 0 to 5m s at 20 to 0 C 0 to 10 m s at 0 to 50 C Measuring range M3 h ari 0 to 99990 m3 h Measuring range A cctsccniseect ceueenak
3. a automaticamente
4. ecnneteeseuneant canes 20 to 50 C Resolution o sason craneo ra aaa 0 01 m s 0 1 C Accuracy system accuracy at calibration temp 25 C 0 1 m s 5 of m v to 2 m s 0 3 m s 5 of m v over 2 m s 05 Ambient temperature aora 0 to 50 C Storage temperature AA O 20 to 70 C e 3 x AAA Battery lifetime taa Approx 20 h approx 750 measurements lasting 2 minutes each Probe 3 21 keene cee eee ee 0 5 in 0 6 in Length 5 9 to 11 8 in A hteardateeardan tenstadu Gueaunntaeseueess 2 years CE guideline cist seisaarntasuaseunaieaananaindaemienimansinitameenadieteain 2004 108 EEC Please read before using instrument e Observe flow direction e Adhere to sensor measuring ranges e Do not exceed maximum storage and operating temperatures e g protect measuring instrument from direct sunlight e Inexpert handling cancels your warranty Changing the battery The battery has to be changed if the T symbol appears in the display during the measurement Y Instrument is switched off 1 Open battery compartment cover 2 Remove spent batteries and insert new batteries 3 x AAA into the battery compartment Observe polarity 3 Close battery compartment cover Auto Off function If no button has been pressed in approx 5 minu _ tes the instrument switches itself off automatically Manual de instrucciones Clip multi uso Sujeciones para posi cionar el mini en con ducto ej en un con d
5. ucto de aire ver fig Anillo de rotaci n la punta de la sonda puede rotar 90 permitiendo una lectura ptima del visualizador Cabezal de protecci n El sensor de velocidad est protegido por un cabezal en la punta de la sonda el cierre de protecci n estar cerrado Se debe dejar abierto solamente durante la medici n Cabezal giratorio El visualizador puede leerse siempre En la cubierta de protecci n hay una flecha que se ala la direcci n del flujo en la que se calibr el instrumento de medici n y con la que se obtienen los mejores resultados Conexi n Tirar cuidadosamente del film protector del visualizador Poner en marcha fon Pulsar la tecla JDD LILI LN m s m m hx10 T test de segmentos Valor de medici n actual Cambiar par metro O Pulsar la tecla repetidas veces Velocidad Ajuste de la secci n del conducto m2 Y Al conectar presionar la tecla On en el visualizador parpadear la posici n ajustable 1 Presionar la tecla On hasta obtener la cifra deseada Esperar 2 segundos se aplica el valor ajustado y el cursor pasa a la siguiente posici n Volumen Temperatura Termoanem metro testo 405 V1 es 2 Repetir el procedimiento anteriormente descrito para todas las posiciones Desconexi n On Presionar la tecla durante 3 segundos Datos t cnicos Tipo de aplicaci n COPPMOA OE E OE E gt 5 medici n breve A ineine nn 0 a 5m s de 20 a 0 C

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual  CURSO DE MANTENIMIENTO PREVENTIVO para Operarios  ResearchTools User Guide  Operating and installation instructions Frost free fridge  Back to Basics CC500 User's Manual    

Copyright © All rights reserved.
Failed to retrieve file