1. modelo 238 sobre el tubo del cabezal y se sujeta fuertemente con el tornillo correspondiente El adaptador fotogr fico esta formado por el tubo fotogr fico el ocular fotogr fico y el visor en el cual se localiza el ocular de enfoque El visor termina en una rosca T sobre ella se coloca la anilla T correspondiente a la c mara fotogr fica y sobre la anilla se coloca el cuerpo de la c mara fotogr fica no incluido Tire de la varilla de observaci n foto que se localiza en el cabezal para colocarla en la posici n foto varilla hacia fuera De esta forma la luz se dirige hacia el tubo fotogr fico reti r ndose del ocular izquierdo Con el anillo de dioptrias del ocular de enfoque g relo hasta ver la cruz de forma n tida El campo que va a ser fotografiado esta englobado dentro del marco del ocular de enfoque fotogr fico Tome las fotograf as utilizando el disparador de la c mara fotogr fica Seguridad Los estereomicroscopios deben ser utilizados por personal cualificado previamente cono ciendo el equipo y su manejo mediante el manual de uso Coloque el estereomicroscopio sobre una mesa horizontal plana y resistente creando un espacio libre al menos de 30 cm por cada lado de ella No coloque el estereomicroscopio en zonas pr ximas a fuentes de calor mecheros sople tes no exponga el equipo directamente a la luz del sol y evite las vibraciones y el polvo Durante el funcionamiento el material peligroso
2. DESCRIPTION 1 R gulateur d intensit de la lumi re incidente 2 Pinces 3 Platine 4 Base 5 Interrupteur teint illumination incidente illumination transmise illumination incidente et transmise 6 Illuminateur incident 7 Commande de contr le de zoom 8 Commande de contr le de mise au point 9 Bague de contr le de friction 10 T te 11 Commande d ajustage dioptrique 12 Oculaires Revision 2 Ao t 04 Manual d usage 50230XXX Page 23 CE FRAN AIS Merci d avoir acquis cet appareil Nous souhaitons sinc rement que vous profitiez du microscope Zuzi s rie 230 Nous vous conseillons de prendre soin de l appareil confor m ment ce qui est crit dans ce manuel Zuzi d veloppe ses produits en insistant sur l ergonomie et s curit de l utilisateur Une utilisation incorrecte de l appareil peut causer des accidents des d charges lectriques des courts circuits des incendies des l sions Nous vous recommandons de lire attenti vement le chapitre consacr la Maintenance La qualit des mat riaux employ s dans la fabrication et une bonne utilisation de l ap pareil vous permettront de profiter de celui ci durant de longues ann es LISEZ ATTENTIVEMENT CE MANUEL D INSTRUCTIONS AVANT D UTILI SER CET APPAREIL A FIN D OBTENIR LES MEILLEURES PRESTATIONS POS SIBLES ET UNE PLUS LONGUE DUREE DE VIE DE CELUI CI Tenez sp cialement compte des aspects suivants Ce manuel est une part
3. photo qui se trouve au niveau de la t te pour la placer en position photo tige vers l ext rieur De cette fa on la lumi re se dirige vers le tube photogra phique de l oculaire gauche Tournez avec la bague de dioptries de l oculaire de mise au point jusqu voir la croix net tement Le champ qui va tre photographi est englob l int rieur du cadre de l oculaire de mise au point photographique Prenez les photographies en utilisant le d clencheur de l appareil photographique S curit Les bains doivent tre utilis s par le personnel pr alablement form sur celui ci et con naissant l appareil et son utilisation gr ce au manuel d instructions Placez le st r o microscope sur une table horizontale plate et r sistante en cr ant un espa ce libre d au moins 30 cm De chaque c t Ne placez pas le st r o microscope dans des zones proche des sources de chaleur Bec Bunsen chalumeau n exposez pas l appareil directement au soleil et vitez les vibrations et la poussi re Pendant le fonctionnement les mat riaux dangereux comme les liquides inflammables ou mat riaux pathologiques doivent tre hors de port Lorsque vous n utiliserez pas l appareil durant une longue p riode de temps v rifiez qu il est d branch Revision 2 Ao t 04 Manual d usage 50230XXX Page 27 g FRAN AIS Installation Avant de commencer utiliser l appareil nous vous conseillons de vous familiariser a
4. rence plus ou moins importante de la mise au point Pour corriger ce d faut vous devrez actionner une commande d ajustage dioptrique plac e sur chaque tube porte oculaires g Page 26 Manual d usage 50230XXX Revision 2 Ao t 04 CASTELLANO topografia de la muestra para centrarse posteriormente en los puntos de mayor inter s para su Observaci n a mayores aumentos a la vez que se pasa de un di metro de campo mayor a uno menor sin necesidad de cambiar los objetivos El rango del zoom de estos modelos es de 0 75X a 3 4X modelo 230 231 y 0 7X a 4 5X modelos 237 238 Para cambiar la platina retire la que este puesta y coloque la que desee Una vez acabado el trabajo aconsejamos desenchufar el equipo puesto que los componen tes el ctricos que lleva el adaptador tienen un peque o consumo el ctrico lo que implica el envejecimiento prematuro del equipo posibles accidentes debido a la producci n de calor as como un gasto innecesario de energ a etc Instalaci n de los objetivos opcionales Si se desea una observaci n a mayores aumentos se puede obtener mediante objetivos opcionales Estos objetivos son de 0 5x y de 2x Se retira la tapa protectora del zoom y se enrosca el objetivo deseado La utilizaci n del zoom no var a Para saber los aumentos que se obtienen ver el cuadro Toma de fotograf as modelos 231 y 238 opcional Se coloca el adaptador fotogr fico referencia 90230011 modelo 231 referencia 90230018
5. 04 Instruction manual 50230XXX Page 19 E ENGLISH In routine observations use the eyepieces with the lowest magnifications and the most powerful objectives Eyepieces with large magnifications are reserved for special situations having in mind they decrease definition and they do not get a better resolution 7 CHOOSING OBJECTIVES AND EYEPIECES For a good functioning of the stereomicroscope it is necessary to follow the recommenda tions and the processes of use we give you Note All the process of use mentioned before will not have any value unless you keep a continued and careful maintenance General recommendations Please follow the processes of use of this manual This manual should be available for all users of these equipments Always use original components and supplies Other devices can be similar but they can damage the equipment The maintenance necessary for these stereomicroscopes is the same that for other optical instruments Always must be kept clean and covered to avoid dust Never try to repair the equipment by yourself since it could produce a defective use of the whole equipment or harm the users burns wounds or cause damages to the electric insta llation Also you can lose the warranty In case of damage or doubt it can be solved getting into touch with the Zuzi Technical Service For any manipulation or cleaning of the equipment please make sure it is disconnected from the net Never disma
6. 6V 15W Zuzi teniendo cuidado de no tocar la ampolla con las manos desnudas IMPORTANTE Antes de reemplazar la bombilla o el fusible aseg rese de desconectar el estereomicroscopio de la red el ctrica Aseg rese de utilizar l mparas hal genas 6V 15W para la iluminaci n incidente el uso de otro tipo de l mparas provocar un mal fun cionamiento del instrumento Para el cambio de la l mpara de iluminaci n incidente primero debe soltar los dos tor nillos que sujetan el soporte de este sistema de iluminaci n LA P g 8 Manual de instrucciones 50230XXX Revisi n 2 de Agosto 04 FRANCAIS Modele Zoom Objectifs Distance de travail 230 0 75x 1 0x 90 mm 231 3 40x 0 5x 150 mm 237 0 70x 1 5x 49 mm 238 4 50x 2 0x 34 mm Modeles 237 238 WP20X augment optionnel 5 INSTALLATION MISE EN MARCHE Inspection pr liminaire D ballez le st r o microscope enlevez la protection de polyester dans laquelle il vient embo t et retirez le plastique qui l enveloppe Faite attention de ne pas le prendre par les commandes de mise au point pour viter que les engrenages de pr cision de mise au point ne s ab me V rifiez qu il n a pas t endommag durant le transport Dans le cas contraire communiquez le imm diatement votre agence de transport ou votre four nisseur afin qu ils fassent les gestions n cessaires Gardez l emballage car en cas de restitution de l appareil celui ci devra toujours tre renvoy
7. Navarra Spain Tel 948 310 513 Fax 948 312 071 Internet www auxilab es Email correo auxilab es Revision 2 Aotit 04 Manual d usage 50230XXX Page 31 E FRAN AIS 8 CAUSES D UNE MAUVAISE IMAGE Dans le cas ou l image serait d fectueuse v rifiez Que l illumination est bien r alis e que l intensit lumineuse ne soit pas excessive ni trop faible Pour le nettoyage de tous le syst me optique vous devez proc der de la mani re sui vante Faites tourner les oculaires en regardant s il y a de la poussi re si c est le cas netto yez les Vous ne devez jamais d monter la t te vous m me mais si vous pouvez netto yez la d licatement en soufflant avec une poire sur les superficies accessibles Si vous disposez un objectif optionnel et les images parasites tournent en le tournant nettoyez le avec l aide d un pinceau sec en essayant d liminer la poussi re observez la superficie frontale avec la loupe ou avec un oculaire inverti 9 ACCESSOIRES Ces st r omicroscopes peuvent se compl ter avec diff rents oculaires et objectifs pour l adapter vos propres besoins Avec le mod le 231 vous obtiendrez des photographies si vous disposez des accessoires photographiques Objectifs Oculaires R f rence Description R f rence Description 90230200 Objectif 0 5x 90230146 Oculaire WF 15x 90230202 Objectif 2x 90230148 Oculaire WF 20x 90230175 Oculaire microm trique 90230191 Oculaire photographique 2 5x 90230193
8. Oculaire photographique 5x Adaptateurs R f rence Description 90230011 Adaptateur photographique pour s rie 230 90230419 Adaptateur vid o 1x Le Page 30 Manual d usage 50230XXX Revision 2 Ao t 04 CASTELLANO INDICE DE CONTENIDOS 1 APLICACIONES DEL INSTRUMENTO ne 3 2 DESCRIPCION cannes vo 3 3 ESPECIFICACIONES TECNICAS 4 4 ESPECIFICACIONES PTICAS 4 5 8 8 8 CAUSAS DE UNA MALA IMAGEN 9 ACCESORIOS re ANEXO I CERTIFICADO CE sssssasoinssensamsesninensennm nenneinnsnss 11 1 APLICACIONES DEL INSTRUMENTO Estos instrumentos sirven para observar im genes ampliadas de peque os objetos siendo la imagen creada estereosc pica no invertida y conservando el color original del objeto observado Los instrumentos Zuzi le ayudar n a solucionar todas las tareas delicadas de con trol investigaci n y documentaci n en las mejores condiciones de trabajo Como aplicaciones de los est reo microscopios destacamos Ense anza b sica secundaria formaci n profesional y universitaria Industria electr nica relojera textil joyer a pintura alimentaci n utillaje fundici n gr fica galvanizado etc en todo proceso de inspecci n montaje y reparaci n de instru mentos placas medidores y otras piezas de precisi n as como en control de calidad Agricultura y ganader a biolog a prot sicos dentales restauraci n art stica filatelia micolog a grafolog a mineralog a ptica investig
9. S L Ee a EU DECLARACI N CE DE CONFORMIDAD ESTEREOMICROSCOPIO ZUZI SERIE 230 de Auxilab S L a la Directiva de M quinas 89 392 CEE modificada y a las reglamentaciones adoptadas para su transposici n NOMBRE DEL FABRICANTE IMPORTADOR AUXILAB S L ISO 9001 2000 DIRECCI N Pol gono Morea Norte 8 31191 Beri in Navarra DECLARAMOS QUE ESTEREOMICROSCOPIO ZUZI SERIE 230 REFERENCIAS 50230030 50230031 50230037 50230038 Esta dise ado y fabricado de acuerdo a Directiva 89 392 CEE incluidas las modificaciones de la misma y las regla mentaciones nacionales que la transponen Directiva 73 23 CEE modificada sobre seguridad el ctrica Directiva 89 336 CEE modificada sobre compatibilidad electromagn tica Y que se han aplicado las siguientes normas armonizadas o parte de ellas UNE 292 1 UNE 292 2 UNE 292 2 A1 UNE 614 1 UNE 1050 UNE 294 UNE 894 1 UNE 894 2 UNE 60204 UNE 61010 1 BERIAIN a 8 de Julio de 2004 Fdo ALFONSO AINCIBURU SANZ DIRECTOR GERENTE Pol gono Morea Norte 8 31191 Beriain Navarra Spain Tel 948 310 513 Fax 948 312 071 Internet www auxilab es Email correo auxilab es Manual de instrucciones 50230XXX P g 11 Li Revisi n 2 de Agosto 04 ENGLISH Thank you for choosing this equipment We sincerely wish that you enjoy your stereomi croscope we highly recommend looking after this equipment according to what is stated in this manual Zuzidevelops its products bei
10. como l quidos inflamables o material patol gico deben estar fuera de este rea Cuando no vaya a hacer uso del equipo por largos periodos de tiempo aseg rese de que est desconectada de la red No intente repararlo usted mismo adem s de perder la garant a puede causar da os en el funcionamiento general del equipo as como lesiones a la persona quemaduras heridas y da os a la instalaci n el ctrica Fabricados seg n la norma europea Revisi n 2 de Agosto 04 Manual de instrucciones 50230XXX P g 7 ul CASTELLANO 6 ELECCI N DE OBJETIVOS Y OCULARES La imagen observada pierde superficie y nitidez a medida que los aumentos son superiores Este incremento de aumentos debe obtenerse mediante objetivos de mayor aumento y no de los oculares ya que el ocular s lo aumenta la imagen dada por el objetivo contra m s aumen tos tenga el ocular mayor es la p rdida de nitidez claridad y superficie que presenta la imagen Para las observaciones rutinarias utilice los oculares de menos aumentos con objetivos m s potentes Los oculares de gran aumento se reservar n para casos particulares teniendo pre sente el hecho de que disminuyen la definici n y no incrementan la resoluci n 7 MANTENIMIENTO Y LIMPIEZA Para un adecuado funcionamiento del estereomicroscopio es necesario seguir algunas recomendaciones Nota Todas las normas de utilizaci n citadas anteriormente carecer n de valor si no se realiza una continu
11. empleados en la fabricaci n y el correcto proceder le per mitir disfrutar del equipo por muchos a os LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE OPERAR CON ESTE EQUIPO CON EL FIN DE OBTENER LAS MAXIMAS PRES TACIONES Y UNA MAYOR DURACI N DEL MISMO Tenga especialmente presente lo siguiente Este manual es parte inseparable del aparato por lo que debe estar disponible a todos los usuarios del equipo Debe manipularse siempre con cuidado evitando los movimientos bruscos golpes ca das de objetos pesados manipulaci n con objetos punzantes Nunca desmonte el equipo para repararlo usted mismo adem s de perder la garant a podr a producir un funcionamiento deficiente de todo el equipo as como da o a las per sonas que lo manipulan Para prevenir fuego o descargas el ctricas evite los ambientes excesivamente h medos Cualquier duda puede ser aclarada por su distribuidor instalaci n puesta en marcha funcionamiento Tambi n puede mandarnos sus dudas o sugerencias a la siguiente direc ci n de correo Servicio T cnico Zuzi asistencia auxilab es Tel fono 807117040 0 30 Euros minuto No olvide rellenar y enviar su certificado de garant a en los 15 d as siguientes a la com pra del estereo microscopio para disponer de un periodo de garant a de dos a os Los fusibles y las l mparas no entran en garant a El fabricante se reserva los derechos a posibles modificaciones y mejoras sobre este ma
12. les 237 238 Pour changer la platine 3 retirez celle qui est mise et placez celle que vous voulez Une fois le travail fini nous vous recommandons de d brancher l appareil tant donn que les composants lectriques de l adaptateur ont une petite batterie lectrique ce qui implique un vieillissement pr matur de l appareil de possibles accidents d la production de cha leur ainsi qu une d pense inutile d nergie etc Installation des objectifs optionnels Si vous souhaitez faire une observation une plus grande chelle vous pouvez le faire gr ce aux objectifs optionnels Ces objectifs sont de 0 5x et de 2x Retirez le couvercle protecteur du zoom et vissez l objectif d sir L utilisation du zoom ne varie pas Pour savoir quelles sont les augmentations obtenues voir le tableau Sp cifications Optiques Prise de Photographies mod les 231 et 238 optionnel Placez l adaptateur photographique R f rence 90230011 mod le 231 R f rence 90230018 mod le 238 sur le tube de la t te et tenez le fortement avec la bague correspondant L adaptateur photographique est form d un tube photographique d un oculaire photogra phique et d un viseur dans lequel se localise l oculaire de mise au point Le viseur termine en vis T Sur celle ci on place une bague en T correspondant la cam ra photographique et sur la bague on place le corps de la cam ra photographique non inclus Tirez de la tige d observation
13. oculaires de moindre grossissement avec un objectif plus puissant Les oculaires de grand grossissement se r serveront pour des cas particuliers tenant compte du fait que la d finition diminue et que la r solution n aug mente pas 7 MAINTENANCE ET NETTOYAGE Pour que le st r o microscope fonctionne correctement nous vous proposons de suivre quelques recommandations Note Il est important de faire un travail continu de maintenance de l appareil afin que vous puissiez en profiter durant de nombreuses ann es Recommandations g n rales Suivez les instructions de mise en garde de ce manuel Le manuel doit toujours tre port de la main de l utilisateur pour qu il puisse le con sulter en cas de besoin Utilisez toujours des composants et pi ces de rechange originaux Il se peut que d au tres dispositifs soient similaires mais leur emploi peut endommager l appareil La maintenance pour ces st r o microscopes est la m me que pour d autres instruments optiques Ils doivent toujours tre propres et couverts par une housse pour viter que la poussi re ne s y d pose Le st r o microscope ne devra tre d mont que par le personnel du Service Technique Zuzi car autrement vous perdriez la garantie Si vous observez de la salet sur les super ficies externes des lentilles nettoyez la avec une petite serviette type essuie verres Pour liminer la poussi re qui s est pos e sur les verres soufflez avec une
14. poire ou nettoyez le avec une petite brosse ou pinceau cheveux naturels Pour le nettoyage des parties m caniques utilisez un lubrifiant non corrosif pour ne pas ab mer la peinture ou la finition Faites attention de ne pas toucher la partie optique Utilisez toujours un d tergent neutre Dans les parties m caniques utilisez un lubrifiant non corrosif en faisant sp ciale attention aux parties optiques Maintenez toujours le st r o microscope dans un lieu frais et sec loin de l humidit et de la poussi re ul Page 28 Manual d usage 50230XXX Revision 2 Ao t 04 CASTELLANO Modelo Zoom Objetivos Distancia de trabajo 230 0 75x 1 0x 90 mm 231 3 40x 0 5x 150 mm 237 0 70x 1 5x 49 mm 238 4 50x 2 0x 34 mm Modelos 237 238 WF10X mm opcional 5 INSTALACION PUESTA EN MARCHA Inspecci n preliminar Desembale el estereomicroscopio quite la protecci n de poliespan en la que viene enca jada y retire el pl stico que la envuelve prestando especial atenci n de no cogerlo por los mandos de enfoque para evitar que sufran los engranajes de precisi n del enfoque Aseg rese de que no presenta ning n da o debido al transporte De ser as comun que lo inmediatamente a su transportista o suministrador para que pueda hacer las debidas reclamaciones en el plazo oportuno WE20X aumentos ZOOM OBJETIVOS mm 16426 0 7 X Guarde el embalaje siempre se deben realizar las devoluciones e
15. toujours des lampes de 6V 15W ZUZI originales pour l illumination incidente N utilisez pas de lampes d intensit sup rieure car cela pourrait causer un surchauffe ment une cassure ou br lure des composants lectriques Pour une illumination transmise utilisez les lampes de 6V 12W Utilisez celle en plastique chaque fois que le st r omicroscope ne sera pas en marche pour viter que la poussi re ne se pose sur les paires optiques Gardez l emballage original pour le transporter et galement pour le ranger lorsque vous ne l utiliserez pas pendant une longue p riode de temps ou lorsque vous l enverrez r parer Mise en marche Connectez correctement le st r o microscope une prise de 220V 10 50 60 Hz pour vue de prise de terre Connectez l illumination incidente et ou transmise qui vous convienne le mieux Pour r guler l intensit de l illumination incidente la base localisez votre commande r gulatrice Ces mod les disposent d une platine en verre meul pour illumination trans misse et une autre de contraste blanc noir pour illumination incidente Observez avec les deux yeux la fois et ajustez la distance interpupilaire jusqu ce que les images des deux yeux se fondent dans une image st r oscopique Centrez l chantillon sur la platine tournez la commande de mise au point lentement jusqu obtenir une image nette En fermant alternativement un oeil puis l autre vous appr cierez une diff
16. 1 0x 90 mm 231 3 40x 0 5x 150 mm 237 0 70x 1 5x 49 mm 238 4 50x 2 0x 34 mm Models 237 238 WF10X WP20X magnifica Field diam magnifica Field diameter me en 16426 32852 opcional 5 INSTALLATION SETTING UP Preliminary inspection Unwrap the stereomicroscope take of the involving plastic and take of the polyspan protection in which it comes fitted please make sure that it does not present any damage because of the shipment If it does please communicate to your transport agent or supplier immediately so that they can make the claims in the correct time limit ZOOM OBJECTIVES 0 7X Please keep the original wrapping you will always need it for returns enclosed with all the accessories supplied Please check that all the accessories are enclosed with the equipment Stage of ground glass Black and white stage Eyepieces WF 10x Protective rubber cups 2 Fuses 0 5 A Plastic cover with Ura Technic and Zuzi printed onit Instruction manual Warranty certificate We will not accept any return of equipments in return unless they come on their origi nal wrapping Installation Before using this instrument it is convenient for you to familiarize with its components and basic essentials PLEASE READ THOROUGHLY THE INSTRUCTIONS BEFORE CONNECTING AND OPERATING WITH THIS EQUIPMENT Version 2 August 04 Instruction manual 50230XXX Page 15 L ENGL
17. ESTEREOMICROSCOPIOS STEREOMICROSCOPES ST R OMICROSCOPES qe 2 mM Serie Series S rie 230 Ss 1o O e a a x gt Este manual es parte inseparable del aparato por lo que debe estar disponi ble a todos los usuarios del equipo Le recomendamos leer atentamente el pre sente manual y seguir rigurosamente los procedimientos de uso para obtener las m ximas prestaciones y una mayor duraci n del mismo This manual should be available for all users of these equipments To get the best results and a higher duration of this equipment it is advisable to read carefully this manual and follow the processes of use Nous vous recommandons lire attentivement cet manuel d instructions et siuvre tous les proc dures d usage fin d obtenir les meilleures preestations et une mayeur duration de l equipe Revisi n 2 de Agosto 04 Manual de instrucciones 50230XXX P g 1 yi 7 CASTELLANO Gracias por haber adquirido este equipo Deseamos sinceramente que disfrute del este reo microscopio Zuzi serie 230 le recomendamos que cuide el equipo conforme a lo expuesto en este manual Zuzi desarrolla sus productos haciendo hincapi en la ergonomia y seguridad del usua rio El uso incorrecto o indebido del equipo puede dar lugar a accidentes y descargas el c tricas cortocircuitos fuegos lesiones lea el punto de mantenimiento donde se recogen los aspectos de seguridad La calidad de los materiales
18. ISH Please put the stereomicroscope on top of a horizontal flat stable table making a free space at least at 30 cm per side Do not put the equipment near any warm supply bur ners blowlamp do not expose it directly to the sun etc During its functioning do not use the equipment near fluids that can give off steams or produce explosive or inflamma ble mixtures The stereo microscope is supplied with a Schuko standard wire Please insert the wire that feeds the A C in the base of current 220V 10 50 60Hz pro vided with earth wire The manufacturer and the distributor will not assume any responsibility for the dama ges produced to the equipment during its installing or damages to persons suffered by the wrong use of the electric connection The tension should be 220V 10 50 60Hz Always use 6V 15W original Zuzi lamps for incident illumination Please do not use lamps of a higher power or you will probably over heat your stereomicroscope For transmitted illumination please use 6 V12W Zuzi fluorescent light Cover the stereomicroscope with the included plastic bag when it is not being used to preserve it from dust laying on optical parts Please keep the original wrapping to cover it when you are not using the equipment for a long time or for a safer transport in case it needs an overhaul Setting up Plug the stereomicroscope to a 220V 10 50 60 Hz socket it must be provided with an earth wire Choose the mo
19. TIONS AE ita 24 5 INSTALLATION MISE EN MARCHE econo 25 6 CHOIX DES OBJETIFS ET OCULA RES ac nu 28 7 MAINTENANCE ET NETTOYAGE Li ne ncatia 28 8 CAUSES D UNE MAUVAISE IMAGE nn 30 J ACCESOIRES ii 30 ANNEXE I CERTIFICAT CE RPM ERNEST 31 1 APPLICATIONS DE L APPAREIL Ces instruments sont sp cialement con us pour observer des images amplifi es de petits objets L image cr e est st r oscopique elle n est pas renvers e et elle conserve la couleur originale de l objet observ Les instruments Zuzi vous aiderons r aliser toutes les t ches d licates de contr le investigation et documentation dans les meilleures condi tions de travail Les applications du st r o microscope Dans l enseignement basique secondaire formation professionnel et universitaire Dans l industrie lectronique d horlogerie textile bijouterie peinture alimentation outillage fonte graphique galvanisation etc dans tous les proc d s d inspection mon tage et r paration d instruments plaque pour mesurer et autres pi ces de pr cision ainsi qu en contr le de qualit Agriculture et levage biologie proth ses dentaires restauration artistique philat lie mycologie graphologie min ralogie optique investigation etc Ces appareils offrent une grande commodit d utilisation et une excellente qualit de l i mage observ e De plus il est possible de disposer de documents authentiques gr ce aux photographies 2
20. a labor de mantenimiento Recomendaciones generales Siga las instrucciones y advertencias relativas a este manual Tenga este manual siempre a mano para que cualquier persona pueda consultarlo Utilice siempre componentes y repuestos originales Puede ser que otros dispositivos sean parecidos pero su empleo puede da ar el equipo El mantenimiento necesario para estos estereomicroscopios es el mismo que para otros instrumentos pticos Siempre deben mantenerse limpios y cubiertos por su funda para evitar que les entre el polvo El estereomicroscopio nunca debe ser desmontado por personal ajeno al Servicio T cnico Zuzi de ser as perder a la garant a Si hubiese cualquier suciedad en las superfi cies externas de las lentes l mpielas con un pa o suave tipo limpia gafas Para eliminar el polvo posado sobre las lentes sople con una pera o l mpielo con un cepillo o pincel suave de pelo natural En la limpieza de las partes mec nicas utilice lubricantes no corrosivos para no da ar la pintura o acabados teniendo especial cuidado de no tocar las partes pticas Use siempre un detergente neutro En las partes mec nicas utilice lubricantes no corrosivos teniendo especial cuidado de no tocar las partes pticas Mantenga el estereomicroscopio siempre en un lugar fresco y seco alejado de la hume dad y del polvo Si se funde la l mpara de iluminaci n incidente reempl cela por otra l mpara hal ge na de
21. aci n etc Estos aparatos ofrecen una gran comodidad en su uso y una excelente calidad de la ima gen observada Adem s es posible disponer de documentos aut nticos mediante fotograf as 2 DESCRIPCI N 1 Regulador de intensidad de la luz incidente 2 Pinzas 3 Platina 4 Base 5 Interruptor apagado iluminaci n incidente iluminaci n transmitida iluminaci n incidente y transmitida 6 Iluminador incidente 7 Mando de control de zoom 8 Mando de control de enfoque 9 Anillo de control de fricci n 10 Cabezal 11 Mando de ajuste di ptrico 12 Oculares aN a BN BR Manual de instrucciones 50230XXX P g 3 Li Revisi n 2 de Agosto 04 CASTELLANO 3 ESPECIFICACIONES T CNICAS Base Met lica muy estable Interruptor Apagado iluminaci n incidente iluminaci n reflejada iluminaci n refle jada y transmitida Iluminaci n Incidente hal gena 6V 15W con control de intensidad Transmitida hal gena 6V 12W Platina De vidrio esmerilado de 75 mm de di metro para iluminaci n transmitida y de contraste blanco negro de 75 mm para iluminaci n incidente Mandos de enfoque Bilaterales con sistema de enfoque por pi n y cremallera con para da de seguridad al final del recorrido Mandos del zoom Bilaterales Cabezal Inclinado 45 y giratorio 360 modelos 237 238 Distancia interpupilar ajusta ble correcci n di ptrica en ambos tubos oculares Binocular e
22. aking textile jewellery paintings food equipments cas ting graphics in every check fixture and repair process and quality control Agriculture and cattle farming minerals biologics arts restoration philately dentists optics research graphology mycology These instruments are very easy to use and they offer a high quality of the observed image Besides it is possible to obtain real documents by taking photographs 2 DESCRIPTION 1 Incident light adjusting knob 2 Stage clips 3 Stage 4 Base 5 Off incident light transmitted light incident and transmitted light 6 Incident light 7 Zoom control 8 Focusing adjusting knob 9 Tension adjusting ring 10 Head 11 Control of dioptric adjustment 12 Eyepieces Version 2 August 04 Instruction manual 50230XXX Page 13 Y ENGLISH ENGLISH If the transmitted illumination lamp blows replace it with a 6V 12W halogen lamp To replace it unscrew all the four screws located at the bottom of the base loosen the Base Iron made very stable Switch Off incident light reflected light reflected and transmitted lamp holder screws and change the lamp making sure you tighten it back If necessary replace the fuse doing as this untwist the protective knob at the back of the Light Incident and transmitted base fuse replace the fuse and place it back in the same position twisting the protective Incident 6 fig 1 6V 15W halogen w
23. alified staff for its correct use so please keep this manual handy to help them learn how to use it properly Please put the stereomicroscope on top of a horizontal flat stable table making a free space at least at 30 cm per side Do not put the stereomicroscope near any warm supply burners blowlamp neither expose it directly to the sun avoid vibrations and dust During its functioning do not use the equipment near fluids that can give off steams or produce explosive or inflammable mixtures Never dismantle the different pieces of the stereomicroscope to repair it yourself since it could produce a defective use of the whole equipment or harm the users by burns wounds or cause damages to the electric installation If you are not going to use the equipment during a long period of time please make sure that it is unplugged from the net Made under European regulations 6 CHOOSING OBJECTIVES AND EYEPIECES The image seen loses surface and sharpness as we increase magnifications This increase must be done by changing to higher magnification objectives and not by changing the eyepie ces as the latter only magnify the image that the objective provides The more magnifications the eyepiece has the bigger will be the decrease on sharpness clarity and surface that the image can undergo Version 2 August 04 Instruction manual 50230XXX Page 17 4
24. and or the equip ment ATTENTION A IF AN EQUIPMENT IS NOT PROPERLY CLEAN AND DISINFECTED IT WOULD NOT BE ALLOWED TO REPAIR BY OUR TECHNICAL SERVICE INDEX OF LANGUAGES Spanish 1 11 4 Page 12 Instruction manual 50230XXX Version 2 August 04 ENGLISH AENOR ISO 9001 2000 Tha AUXILAB S L E Lips Beyisuado TEO CE DECLARATION OF CONFORMITY STEREOMICROSCOPE ZUZI SERIES 230 of Auxilab S L for the Directive of Machines 89 392 CEE modified and for the regulations adpoted for their transposition NAME OF THE MANUFACTURER IMPORTER AUXILAB S L ADDRESS Pol gono Morea Norte 8 31191 Beri in Navarra WE STATE THAT STEREOMICROSCOPES ZUZI SERIES 230 CODES 50230030 50230031 50230037 50230038 Are designed and manufactured according to Directive 89 392 CEE including the modifications and the national regulations that transpose them Directive 73 23 CEE modified over the electric security Directive 89 336 CEE modified over the electromagnetic compatibility And that the following harmonized rules have been applied or part of them UNE 292 1 UNE 292 2 UNE 292 2 A1 UNE 614 1 UNE 1050 UNE 294 UNE 894 1 UNE 894 2 UNE 60204 UNE 61010 1 BERIAIN 8th July 2004 Signed by ALFONSO AINCIBURU SANZ DIRECTOR MANAGER Pol gono Morea Norte 8 31191 Beriain Navarra Spain Tel 948 310 513 Fax 948 312 071 Internet www auxilab es Email correo auxilab es ore Version 2 August 04 Inst
25. as y cambie la misma volviendo a sujetarla firmemente Si fuese necesario remplazar el fusible h galo seg n el siguiente procedimiento desen chufe desenrosque la tapa protectora que se encuentra en la parte posterior de la base Fuse reemplace el fusible y vuelva a colocarlo en la misma posici n enroscando de nuevo la tapa protectora El estereomicroscopio dispone de un cable de red Schuko este debe conectarse a una toma de corriente provista de toma a tierra debiendo quedar a mano para poder desco nectarlo en caso de emergencia En caso de aver a dir jase a su proveedor para su reparaci n a trav s del Servicio T cnico de Zuzi La manipulaci n de los circuitos electr nicos internos del est reo microscopio por per sonal no autorizado puede provocar da os de dif cil reparaci n Aseg rese de llevar el equipo al Servicio T cnico de Zuzi Limpieza Para la limpieza de las diferentes piezas del aparato recomendamos se utilicen pro ductos neutros que no contengan agentes abrasivos como por ejemplo unas gotas de jab n de limpieza de cristal rebajado en agua No verter nunca el preparado sobre el equipo acost mbrese siempre a humedecer un trapo suave con dicho producto ATENCI N A NO SE ADMITIRA NINGUN APARATO PARA REPARAR QUE NO ESTE DEBIDAMENTE LIMPIO Y DESINFECTADO 8 CAUSAS DE UNA MALA IMAGEN En caso de una imagen deficiente comprobar Que la iluminacion est bien realizada que la inten
26. changement de lampe d illumination incidente il faut d abord d vissez les deux vis qui tiennent le support de ce systeme d illumination Desserrer les vis qui tiennent le support des lampes puis desserrez les deux vis qui tiennent la lampe et remplacez la par une neuve Replacez le support des lampes dans le support et celui ci la base V rifiez de bien tout r gler correctement Sila lampe d illumination transmise grille changez la par une lampe 6V 12W Pour le changement de lampe de l illumination transmise desserrez les quatre vis qui tiennent la partie inf rieure de la base desserrez les vis du support des lampes et chan gez la m me en la tenant fermement Si il est n cessaire de remplacer le fusible faites le comme suit d branchez d vissez le couvercle protecteur qui se trouve dans la partie post rieure de la base Fuse remplacez le fusible et replacez le dans la m me position en vissant de nouveau le couvercle pro tecteur Le st r o microscope dispose d un c ble de r seau Schuko celui ci doit se connecter une prise de courent pourvue de prise de terre elle doit tre port de la main pour pou voir tre d branch e en cas d urgence En cas de panne dirigez vous votre fournisseur pour la r paration travers du Service Technique de Zuzi La manipulation des circuits lectroniques internes du st r o microscope par le per sonnel non autoris peut provoquer des dommages difficilement r parabl
27. dans son emballage original accompagn galement de tous les accessoires four nis initialement ZOOM OBJECTIFS mm 16426 32852 0 7X y 45X V rifiez les accessoires que vous devez recevoir avec l appareil Platine en verre meul Platine blanche noire Oculaires WF 10x Paire de bonnette 2 Fusibles 0 5 A 1 Housse en plastique avec l inscription Ura Technic et Zuzi Garantie Manuel d utilisation Nous n accepterons aucun appareil en p riode de restitution sans son emballage original Revision 2 Ao t 04 Manual d usage 50230XXX Page 25 ul FRAN AIS 3 SP CIFICATIONS T CHNIQUES Base M tallique tr s stable Interrupteur teint illumination incidente illumination r fl chie illumination r fl chie et transmise Illumination Halog ne 6V 15W avec contr le d intensit Transmise halog ne 6V 12W Platine En verre meul de 75 mm de diam tre pour illumination transmise et de con traste blanc noir de 75 mm pour illumination incidente Commandes de mise au point Bilat rales avec syst me de mise au point par pignon et cr maill re avec arr t de s curit la fin du parcours Commandes du zoom Bilat rales T te Inclinaison 45 et giratoire 360 mod les 237 238 Distance interpupilaire ajusta ble correction dioptrie dans les deux tubes oculaires Binoculaire dans les mod les 230 et 237 Trioculair
28. e avec sortie pour appareil photo pour mod les 231 et 238 Une pair de bonnette En caoutchouc 4 SP CIFICATIONS OPTIQUES Oculaires WF grand champ 10X diam tre de champ de 20 mm Zoom Le zoom permet une adaptation continue de l augmentation sans que l image ne perde sa puret La commande du zoom modifie de fa on continue le facteur augmenta tion de 0 75X 3 4X mod les 230 231 et de 0 7X 4 5X mod les 237 238 La distance de travail reste invariable pour toute la marge du zoom Il est op ratif de chaque c t avec une parafocalit totale et centr Options Oculaire WF 20X Oculaire photographique 5X Oculaire WF 15X Objectif 0 5X Oculaire photographique 2 5X Objectif 2 0X Mod les 230 231 WF10X WF15X WE20X ho Es mm mm mm 0 75 X 16 35 32 7 106 235 34X 13 29 22 5x 102x 10 22 30x 136x 8 1 76 optionnel Li 4 Page 24 Manual d usage 50230XXX Revision 2 Ao t 04 CASTELLANO Afloje los tornillos que sujetan el porta lamparas despu s afloje los dos tornillos que sujetan la lampara y reemplacela por una nueva Vuelva a colocar el porta lamparas en su soporte y ste en la base Asegurese de ajustar todo correctamente Si se funde la l mpara de iluminaci n transmitida c mbiela por una l mpara 6V 12W Para el cambio de l mpara de iluminaci n transmitida suelte los cuatro tornillos que sujetan la parte inferior de la base afloje los tornillos del portal mpar
29. es Assurez vous d envoyer votre appareil au Service Technique de Zuzi Nettoyage Pour le nettoyage des diff rentes pi ces de l appareil nous vous conseillons d utiliser des produits neutres sans agent abrasif comme par exemple une go te de savon pour len tilles m lang de l eau Ne versez jamais la pr paration sur l appareil Prenez l habitude d humidifier une peti te serviette avec ce produit ATTENTION A AUCUN APPAREIL NE SERA R PAR S IL N A PAS PR ALABLEMENT T CORRECTEMENT NETTOY ET D SINFECT Revision 2 Ao t 04 Manual d usage 50230XXX Page 29 LU FRAN AIS N essayez pas de le r parer vous m mes car en plus de perdre la garantie vous pouvez causer des dommages au fonctionnement g n ral de l appareil ainsi que des dommages cor porels br lures blessures et des d g ts l installation lectrique Fabriqu s conform ment la norme Europ enne 6 S LECTION DES OBJECTIFS ET OCULAIRES L image observ e perd de sa superficie et nettet au Fur et mesure que les grossisse ments sont sup rieurs Cet accroissement d augmentation doit s obtenir par l objectif de plus grande augmen tation et non des oculaires tant donn que l oculaire n augmente que l image donn e par l objectif Plus l oculaire a des possibilit s de grossissement moins la nettet la clart et la superficie que repr sente l image seront bonnes Pour les observations routini res utilisez les
30. ie ins parable du microscope c est pourquoi il devra toujours tre la port de tous les utilisateurs Cet appareil doit toujours se manipuler avec pr caution en vitant les mouvements brusques coups chutes d objets lourds manipulations avec des objets pointus Ne d montez jamais l appareil pour le r parer vous m me car en plus de perdre la garantie cela pourrait provoquer des blessures aux utilisateurs Pour viter des incendies et des d charges lectriques ne laissez pas l appareil dans des endroits excessivement humides En cas de besoin n h sitez pas contacter votre fournisseur vous pouvez nous con sulter si vous avez des questions sur l installation la mise en marche le fonctionnement Vous pouvez galement nous envoyer vos suggestions l adresse e mail du Service Technique Zuzi asistencia auxilab es Le fabriquant se r serve le droit de modifier et d am liorer ce manuel ainsi que l appareil N oubliez pas de remplir et d envoyer votre certificat de garantie dans les quinze jours qui suivent l achat du bain cela vous permettra de disposer d une p riode de garantie de deux ans Les fusibles et accessoires ne sont pas sous garantie T CORRECTEMENT NETTOY ET D SINFECT TRADUCTION EN ESPA aaa A IA 12 21 Francais ATTENTION A AUCUN APPAREIL NE SERA REPARE S IL N A PAS PREALABLEMENT z Page 22 Manual d usage 50230XXX Revision 2 Ao t 04 CASTELLANO AENOR a AUXILAB
31. ith intensity control knob back again Transmitted halogen 6V 12W The stereomicroscope is supplied with a Schuko standard wire and it should be con Stage Frosted glass of 75 mm diameter for transmitted illumination and black white nected to a current wire provided with an earth wire it should be handy to be discon contrast of 75 mm diameter for incident illumination nected in case of emergency Focusing adjusting knob Bilateral by pinion and rack focusing system and security stop at the end of the haul Cleaning Zoom control Bilateral For cleaning the stainless steel steam parts use always a special cloth that does not give Head 45 inclined and rotary 360 models 237 238 Adjustable interpupillary distan off fluff Do not use any cloth that can produce damages to the equipment ce dioptric adjustment in both ocular tubes For cleaning the different pieces of the equipment we highly recommend to use neutral Binocular on models 230 and 237 products that do not have a pH superior than 6 soaped water without abrasives Trinocular with a tube for photographic attachment on models 231 and 238 5 ATTENTION Protective rubber cups To protect your eyes IF AN EQUIPMENT IS NOT PROPERLY CLEAN AND DISINFECTED IT 4 OPTICAL SPECIFICATIONS Eyepieces WF wide field 10X field s diameter of 20 mm 8 CAUSES OF A DEFECTIVE IMAGE Zoom It enables a continuous adjust of the magnified image without loosing sharpness T Its z
32. le Schuko est ndar Inserte el cable de alimentaci n de corriente alterna CA a la base de corriente 220V 10 50 60Hz provista de toma de tierra Ni el fabricante ni el distribuidor asumir n responsabilidad alguna por los da os ocasio nados al equipo instalaciones o lesiones sufridas a personas debido a la inobservancia del correcto procedimiento de conexi n el ctrica La tensi n debe ser de 220V 10 50 60Hz Cuando no vaya a hacer uso del estereomicroscopio durante largos periodos de tiempo aseg rese de que est desconectada de la red Use siempre l mparas de 6V 15W Zuzi originales para la iluminaci n incidente No uti lice l mparas de mayor potencia ya que podr a producir un sobrecalentamiento rotura o quemado de componentes el ctricos Para iluminaci n transmitida utilice l mparas de 6V 12W Utilice la funda de pl stico siempre que el estereomicroscopio no este en uso para evi tar que el polvo se pose sobre las partes pticas Guarde el embalaje original para transportarlo as como cuando no vaya a utilizarse durante mucho tiempo o cuando haya que enviarlo a revisar Puesta en funcionamiento Conecte correctamente el estereomicroscopio a un enchufe de 220V 10 50 60 Hz provisto de toma de tierra Conecte la iluminaci n incidente y o transmitida m s conveniente a su observaci n Para regular la intensidad de la iluminaci n incidente en la base se localiza su mando regulador Estos modelo
33. lectricity This can age the stereomicroscope too soon cause damages due to the heating output as well as an unnecessary waste of energy etc Page 16 Instruction manual 50230XXX Version 2 August 04 ENGLISH Installation of the optional objectives If you need more accurate magnifications you can attach optional objectives as 0 5x and 2x Remove the zoom s protective knob and screw the objective required Zoom usage is exactly the same To know the magnifications you can obtain see the chart on Optical spe cifications Taking photographs models 231 and 238 optional Place the photographic attachment code 90230011 model 231 or 90230018 model 238 over the head s tube and screw it on This adapter is composed by a photographic tube a photographic eyepiece and a viewfinder where the focusing eyepiece is located The viewfinder ends in a T thread where you have to screw the corresponding T mount ring not included and then over it screw the photographic camera Pull the observation photo rod located in the head to place it in photo position out wards This way the light is directed towards the photography tube withdrawing from the left eyepiece With the focusing ocular dioptric ring turn it until you see the cross sharply The field to be photographed has to be on the photographic focusing eyepiece frame Take photographs by pressing the camera s release Security The stereomicroscope has to be handled by qu
34. n los modelos 230 y 237 Triocular con salida para c mara fotogr fica en modelos 231 y 238 Par de anteojeras De goma 4 ESPECIFICACIONES PTICAS Oculares WF gran campo 10X di metro de campo de 20 mm Zoom El zoom permite una adaptaci n continua del aumento sin que la imagen pierda nitidez El mando del zoom modifica de forma continua el factor de aumento de 0 75X a 3 4X modelos 230 231 y de 0 7X a 4 5X modelos 237 238 La distancia de trabajo per manece invariable para todo el margen del zoom Es operativo a ambos lados con total parafocalidad y centrado Opcionales Ocular WF 20X Ocular fotogr fico 5X Ocular WF 15X Objetivo 0 5X Ocular fotogr fico 2 5X Objetivo 2 0X Modelos 230 231 WF10X WFI5X WRP20X de gee mm mm mm 0 75 X 16 35 30 7 106 235 34X 13 29 22 5x 102x 10 22 30x 136x 8 1 76 opcional Li 7 P g 4 Manual de instrucciones 50230XXX Revisi n 2 de Agosto 04 FRANCAIS Si la lampe d illumination incidente grille remplacez la par une autre qui soit haloge ne de 6V 15W Zuzi en faisant attention de ne pas toucher l ampoule avec les mains nues IMPORTANT Avant de remplacer l ampoule ou le fusible v rifiez que le st r omi croscope est d branch V rifiez bien que les lampes halog nes que vous utilisez sont bien de 6V 15W pour illumination incidente L utilisation d un autre type de lampe peut pro voquer un mauvais fonctionnement de l appareil Pour le
35. n su embalaje original con todos los accesorios suministrados Compruebe los accesorios que usted debe recibir junto al equipo Platina de vidrio esmerilado Platina blanco negro Oculares WF 10x Par de anteojeras 2 Fusibles 0 5 A 1 Funda de pl stico con la inscripci n Ura Technic y Zuzi Garant a Manual de uso No aceptaremos ning n equipo en periodo de devoluci n sin que vaya en su embalaje original Manual de instrucciones 50230XXX P g 5 Y Revisi n 2 de Agosto 04 CASTELLANO Instalaci n Antes de comenzar a utilizar el instrumento es conveniente familiarizarse con sus com ponentes y fundamentos b sicos as como con las funciones de sus controles LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE CONECTAR Y OPERAR CON ESTE EQUIPO Coloque el estereomicroscopio sobre una mesa horizontal plana y estable creando un espacio libre al menos de 30 cm por cada lado No coloque el estereomicroscopio en zonas pr ximas a fuentes de calor mecheros sopletes no exponga directamente a la luz del sol etc Durante el funcionamiento el material peligroso como l quidos inflamables o material patol gico deben estar fuera de este espacio Retire el papel y las gomas que lo protegen del polvo as como la tapa protectora del objetivo Coloque sobre los oculares el par de anteojeras Coloque la platina que necesite sobre la base El estereomicroscopio se suministra con un cab
36. ng remarkable in the ergonomics and security of its user The incorrect use of the equipment can cause accidents and electric discharges circuit breakers fires damages Please read the point of Maintenance where we expose the security notes The correct using of the equipment and its good quality will permit you to enjoy this equip ment for years TO GET THE BEST RESULTS AND HIGHER DURATION OF THE EQUIPMENT IT IS ADVISABLE TO READ THOROUGHLY THIS MANUAL BEFORE OPERA TING WITH THE EQUIPMENT Please take in mind the following This manual should be available for all the users of these equipments We should handle it carefully avoiding the sudden movements knocks or free fall of heavy objects and its manipulation with sharp objects Never dismantle the different pieces of the stereomicroscope to repair it yourself since it could produce a defective use of the whole equipment and a loss of the product warranty To avoid fire o electric discharges avoid humid environments If you have any doubt about setting up installation or functioning do not hesitate in con tacting your distributor or our ZUZI Technical Assistant Department by email asistencia auxilab es Please do not forget filling the Warranty Certificate and send it before 15 days after the date of purchase in order to obtain the two year warranty Neither lamps nor fuses are included in warranty The manufacturer reserves the right to modify or improve the manual
37. ntle the different pieces of the stereomicroscope to repair it yourself since it could produce a defective use of the whole equipment and a loss of the product warranty Users must never take lens apart If the outer lens surfaces were dirty clean them with a smooth cloth avoid fuzzy cloths previously dampen in xilol or toluene To eliminate dust on lens blow them with a pear or clean them with a soft natural hair brush In mechanical components use non corrosive lubricant to avoid damages in paintings or terminations paying special attention to avoid optical components contact Always use aneu tral detergent Keep the stereomicroscope in a dry and fresh environment out of humidity or even dust If an incident illumination lamp blows replace it with a halogen 6V 15W Zuzi lamp avoi ding contact with bare hands IMPORTANT before replacing a bulb or a fuse please make sure you have your equip ment unplugged Check you use a 6V 15W halogen lamp for incident illumination because any other kind of lamp will cause a failure in the equipment To replace the incident illumination lamp unscrew both the illumination system holder screws Unscrew the two lamp holder screws and then replace the lamp Put the lamp hol der back in its socket and this in the base Make sure you have well adjusted every compo nent L Page 18 Instruction manual 50230XXX Version 2 August 04 ENGLISH Model Zoom Objectivoes Working distance 230 0 75x
38. nual y equipo ATENCI N NO SE ADMITIRA NINGUN APARATO PARA REPARAR QUE NO ESTE DEBIDAMENTE LIMPIO Y DESINFECTADO INDICE DE IDIOMAS PP ees ieee eed 1 11 PPP secs osactsbasergussiesvas sites cbsnvaancestiae 12 21 Prange cesses o E E E E ented oeeeei nat etree 22 31 Li 7 P g 2 Manual de instrucciones 50230XXX Revisi n 2 de Agosto 04 FRANCAIS AENOR 150 9001 2000 a AUXILAB S L E Emp Beyistrado TEO D CLARATION CE DE CONFORMIT STEREO MICROSCOPIE ZUZI SERIE 230 d Auxilab S L la Directive des Machines 89 392 CEE modifi e et aux r glementations adopt es pour sa transposition NOM DU FABRICANT IMPORTATEUR AUXILAB S L ADRESSE Pol gono Morea Norte 8 31191 Beri in Navarra D CLARONS QUE ___ STEREO MICROSCOPE ZUZI S RIE 230 R F RENCES 50230030 50230031 50230037 50230038 Est dessin et fabriqu conform ment Directive 89 392 CEE incluant les modifications de celle ci et les r glementa tions nationales qui la transposent Directive73 23 CEE modifi e sur la s curit lectrique Directive 89 336 CEE modifi e sur la compatibilit lectromagn tique Et que les normes harmonis es suivantes ou une partie ont t appliqu es UNE 292 1 UNE 292 2 UNE 292 2 A1 UNE 614 1 UNE 1050 UNE 294 UNE 894 1 UNE 894 2 UNE 60204 UNE 61010 1 BERIAIN le 8 Juillet 2004 Sign par ALFONSO AINCIBURU SANZ DIRECTEUR GERENT Poligono Morea Norte 8 31191 Beriain
39. oom control changes continuously the magnifying factor from 0 75X to 3 4X models In case of obtaining a deficient image check the following WOULD NOT BE ALLOWED TO REPAIR BY OUR TECHNICAL SERVICE 230 231 and from 0 75X o 4 5X models 237 238 The working distance is exactly the That the illumination is well done that the luminous intensity is neither excessive nor same for all zoom range It is operative at both sides always being absolutely parafocal too weak and centred That the optical system is clean proceeding like this turn and extract the eyepieces to Optional see if there are little drops of dust or dirt and if so clean them You must never dismantle WF 20X eyepiece 5X photographic eyepiece the head but you can clean it carefully blowing with a pear the accessible parts If you WE 15X evepiece 05X obiective own an optional objective and parasite images rotate at the same time you rotate the objec 25X ph yep hi 2 0X A tive clean it by using a dry brush trying to eliminate the dust You should observe the 2 5X photographic eyepiece TAUA OpjecHve front part with a magnifier or with an inverted ocular for a conscientious cleaning Models 230 231 WF10X WF15X WF20X ZOOM OBJECTIVES magnifica Field diam magnifica Field diam magnifica Field diameter in ire mn 0 75 X 16 35 y 32 7 106 235 34X 8 176 optional Ly Page 14 Instruction manual 50230XXX Version 2 August 04 Version 2 August
40. ruction manual 50230XXX Page 21 Y ENGLISH 9 ACCESSORIES Different eyepieces and objectives can be attached depending on special needs You can take photographs with model 231 if you have photography accessories Objectives Eyepieces Code Description Code Description 90230200 Objective 0 5x 90230146 Eyepiece WF 15x 90230202 Objective 2x 90230148 EyepieceWF20x __ __ 90230175 Micrometric eyepiece 90230191 Photographic eyepiece 2 5x 90230193 Photographic eyepiece 5x Adapters Code Description 90230011 Photographic adapter for series 230 90230419 Video adapter 1x A Page 20 Instruction manual 50230XXX Version 2 August 04 ENGLISH 1 USES OF THE EQUIPMENT nn 13 2 DESCRIPTION us 13 3 TECHNICAL SPECIFICATIONS 14 4 INSTALLATION SETTING UP 5 MANTEINANCE AND CLEANING 6 TROUBLESHOOTING 7 CHOOSING THE OBJECTIVES AND EYEPIECES nn 18 8 CAUSES OF A DEFECTIVE IMAGE nu 419 9 ACCESSORIES rires wn 20 ANNEX CE CERTIFICATE scsi 21 1 USES OF THE EQUIPMENT These instruments are useful to observe enlarged images of small items The image is not inverted but stereoscopic and maintains the sample s original colour when seen through the eyepiece Zuzi equipments will help you in most difficult tasks related to control research and documentation in the best work conditions As more remarkable applications we stand out Education primary secondary practical and university education Industry electronics watchm
41. s disponen de una platina de vidrio esmerilado para iluminaci n transmitida y otra de contraste blanco negro para iluminaci n incidente Observe por ambos ojos a la vez y ajuste la distancia interpupilar hasta que las im ge nes de ambos ojos se fundan en una imagen estereosc pica Centre la muestra en la platina gire el mando de enfoque lentamente hasta conseguir una imagen n tida Cerrando alternativamente un ojo y despu s el otro se apreciar una diferencia m s o menos acusada del enfoque para corregir este defecto habr que accio nar un mando de ajuste di ptrico que lleva cada uno de los dos tubos porta oculares Estos modelos poseen una destacada ventaja la posibilidad de cambiar los aumentos de forma continua As se puede obtener con pocos aumentos una imagen de conjunto de la ul Pag 6 Manual de instrucciones 50230XXX Revision 2 de Agosto 04 FRANCAIS Ces mod les poss dent un grand avantage la possibilit de changer les grossissements de fa on continue De cette fa on vous pouvez obtenir avec peu d augmentation une image d ensemble de la topographie de l chantillon pour se centrer post rieurement dans les points de plus grand int r t pour son observation plus grand grossissement en m me temps que vous passez d un diam tre de champ plus grand un autre moins grand sans avoir besoin de changer les objectifs Le rang du zoom de ces mod les est de 0 75X a 3 4X mod le 230 231 et 0 7X 4 5X mod
42. sidad luminica no sea excesiva ni demasiado d bil La limpieza de todo el sistema ptico procediendo de la siguiente manera haga girar los oculares contemplando si las motitas se mueven si es as l mpielos Nunca debe des montar el cabezal pero s puede limpiar delicadamente soplando con una pera aquellas superficies accesibles Si dispone de objetivo opcional y las im genes par sitas giran al girarlo limpiarlo con la ayuda de un pincel seco intentando eliminar el polvo observe la superficie frontal con una lupa o con un ocular invertido Manual de instrucciones 50230XXX P g 9 bj Revisi n 2 de Agosto 04 CASTELLANO 9 ACCESORIOS Estos estereomicroscopios pueden ser completados con diversos oculares y objetivos para adecuarlo a sus necesidades particulares Con el modelo 231 se pueden obtener foto grafias si se dispone de los accesorios fotogr ficos Objetivos Oculares Referencia Descripci n Referencia Descripci n 90230200 Objetivo 0 5x 90230146 Ocular WFT5x 90230202 Objetivo 2x 90230148 Ocular WF20x 90230175 Ocular microm trico 90230191 Ocular Fotogr fico 2 5x 90230193 Ocular Fotogr fico 5x Adaptadores Referencia Descripci n 90230011 Adaptador fotogr fico para serie 230 90230419 Adaptador de video 1x 7 P g 10 Manual de instrucciones 50230XXX Revisi n 2 de Agosto 04 FRANCAIS INDEX DE CONTENUS 1 APPLICATIONS DE L APPAREIL nn 23 DESERT TOM Re 23 3 SPECIFICATIONS TECHNIQUES cc 24 4 SP CIFICA
43. st suitable light source incident and or transmitted light according to the sample you are going to observe To adjust the incident illumination strength use the adjusting knob in the base These models have a ground glass stage for transmitted illumination and other for black white incident illumination Watch through both eyepieces at the same time and adjust the interpupilar distance until both images become one stereoscopic image Place the sample in the middle of the stage slowly turn the focusing control until you see a sharp image By alternating the vision first with one eye closed then with the other you will appreciate an important focusing difference to correct it you will have to use the dioptric adjustment in each ocular tube These models have an important advantage magnifications can be continuously adap ted This way you can get a whole image of the sample s topography with few magnifica tions and then you can observe with more detail the part you are more interested in At the same time you can change the field s diameter from a larger diameter to a shorter one without changing the objectives The zoom range in these models goes from 0 75X to 3 4X model 230 231 and 0 7X to 4 5X model 237 238 To replace the stage remove the one you were using and put the new one Once you have finished working with the equipment we strongly recommend you to unplug it as the electric components that its adapter has consume e
44. vec ses composants et fondements basiques ainsi qu avec les fonctions de ses contr les LISEZ ATTENTIVEMENT CE MANUEL D INSTRUCTIONS AVANT D UTILI SER L APPAREIL Placez le st r o microscope sur une table horizontale plate et stable en cr ant un espa ce libre d au moins 30 cm de chaque c t Ne le placez pas dans des endroits proche des sources de chaleur Bec Bunsen chalumeau Ne l exposez pas directement au soleil etc Pendant son utilisation le mat riel dangereux comme les liquides inflammables ou mat riel pathologique doivent tre hors de port Retirez le papier qui le prot ge de la poussi re ainsi que le couvercle protecteur de l objectif Placez sur les oculaires la paire de bonnette sur les oculaires Placez la platine dont vous avez besoin sur la base Le st reo microscope est livr avec un c ble Shuko standard Introduisez le c ble de l alimentation du courent alterne CA la base de courent 220V 10 50 60Hz pourvue de prise terre Dans le cas ou la proc dure de connexion ne serait pas suivie correctement suivant les indications donn es le fabricant et le distributeur n assumerons ni la responsabilit des d g ts caus s l appareil ni les blessures produites aux personnes usager ou non La tension doit tre de 220V 10 50 60Hz Lorsque vous n utiliserez pas le st r o microscope pendant une longue p riode de temps v rifiez bien que l appareil est d branch Utilisez