Home

The Jennix™ - Fanimation

image

Contents

1. 2 from Supply from Hanger N p NOTE If you feel that you do not have enough electrical Bracket Ground wiring knowledge or experience have your fan installed Se UD by a licensed electrician from Hanger Black Wire Ball Ground from Fan WARNING Check to see that all connections are tight including Figure 2 ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until the blades are in place Noise and motor damage could result HARDWARE USED WIRE x 3 CONNECTORS How to Wire Your Ceiling Fan continued 2 After connections have been made turn leads 1 upward and carefully push leads into the outlet box with the white and green leads to one side of the box and the black leads toward the other side Figure 3 Green Wire from Supply White Wire Ground from Supply Listed Outlet Box 3 Household Supply Black Wire Green Wire L 2 from Supply from Hanger N ye Bracket Ground N Green Wire from Hanger Black Wire Ball Ground from Fan Figure 3 How to Install Your Canopy Housing Remove one of the two shoulder screws in the hanger bracket Loosen the second shoulder screw without fully removing it Assemble canopy by rotating key slot in canopy over shoulder screw in hanger bracket Tighten shoulder screw Fully assemble and tighten second shoulder screw that was previously removed Figure 1 WARN
2. Para evitar una posible descarga el ctrica aseg rese de cortar la alimentaci n el ctrica de la caja de fusibles principal antes de colgar el ventilador Figura 1 On l Off O 0 40 1 u0 PRINCIPAL CAJA DE FUSIBLES On l On l HE E Off O E 0 40 HIE 4O 1 UO On l H Off O 0 40 H UO NOTA Si no est seguro de si la caja de salida tiene conexion a tierra pida consejo a un electricista certificado ya que debe tener conexion a tierra para un funcionamiento seguro A ADVERTENCIA Debe colgar el ventilador a una distancia minima de 2 13 m desde las aspas hasta el piso Figura 2 m r m 1 Fije bien la abrazadera para colgar a la caja de menos de 2 13 m salida con los tornillos y las arandelas provistas con la ES O caja de salida Figura 3 2 Perfore un orificio de 1 4 en la estructura del edificio i l i de l Figura 2 para evitar grietas con la instalaci n del tornillo de intervalo Utilice el tornillo de intervalo de 3 8 x 2 y la Miembro de as madera 5 x 10 cm Viga del techo arandela plana para fijar el cable de seguridad a la viga 2 x 4 aprox del techo o a la estructura de madera Dicho tornillo pasar a trav s de arandela plana la presilla del cable de seguridad y se fijar en la estructura del edificio Figura 3 NOTA el cable de soporte para techo no se puede asegurar solamente a la caja de conexiones se debe asegurar directamente a la viga de techo o mi
3. 50 Ibs or 22 73 kgs See page 5 of owner s manual for support requirements Consult a qualified electrician if in doubt The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not have adequate electrical knowledge or experience have your fan installed by licensed electrician WARNING This product is designed to use only those parts supplied with this product and or accessories designated specifically for use with this product Using parts and or accessories not designated for use with this product could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade bracket flange or blade holder when installing the brackets or cleaning the fan Do not insert foreign objects in between rotating fan blades This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation If the intentional radiator can be classified as a Class B digital device or a PC peripheral then shall include the following or equivalent Note This equipment has been tested and found to comply with the limits for Class B digital device pursuant
4. Suministro ventilador al conductor blanco neutro mediante el Conductor el ctrica conector provisto de forma segura Conecte el conductor NN cons f onductor negro negro del motor del ventilador y el conector azul al Condicerveds L Ni ne conducto negro mediante el conector provisto de forma de la abrazadera Z ara colgar is Figura 2 puesta aierra NOTA Si no est seguro de si la caja de salida tiene Conductor verde E de la bola onductor negro conexi n a tierra pida consejo a un electricista certificado para colga del ventilador ya que debe tener conexi n a tierra para un funcionamiento puesta a tierra seguro A ADVERTENCIA ONE Verifique que todas las conexiones est n ajustadas incluida la conexi n a tierra y que no haya conductores Aditamentos utilizados desnudos visibles en los conectores excepto el conductor con conexi n a tierra No opere el ventilador hasta que las Fedre ls aspas est n instaladas Podr a ocasionar ruidos y da os al de cable motor 25 C mo realizar la instalaci n el ctrica del ventilador de techo cont 2 Una vez realizadas las conexiones gire los conductores hacia arriba y con cuidado col quelos dentro de la E Conductor verde Conductor blanco caja de salida con los conductores blancos y verdes puesta a tierra del suministro y cai de salida hacia un lado y los conductores negros hacia el otro RN XT q homologada Figura 3 O Suministro Conductor E b
5. del soporte de barral est n flojos 2 El tornillo de fijaci n en la unidad del barral de la semiesfera est flojo 3 Los tornillos que aseguran as aspas al buje del motor est n flojos 4 Los aspas no est n colocados correctamente 5 El soporte de suspensi n o la caja de distribuci n el ctrica del techo no est n bien asegurados 32 1 Controle los fusibles del circuito principal y derivado o los disyuntores 2 Controle las conexiones el ctricas del ventilador y del interruptor en las cajas de los interruptores PRECAUCI N Aseg rese de que el suministro principal de electricidad est desconectado 3 Reemplace con una bater a nueva 1 Ajuste las aspas al ventilador antes de ponerlo en funcionamiento 2 Aseg rese de que todos los tornillos de la caja del motor est n bien ajustados pero no en exceso 3 Aseg rese de que los tornillos que fijan los aspas al buje del motor del ventilador est n bien ajustados 4 Aseg rese de que los conectores de cables en la caja del interruptor no produzcan ruido al rozar unos con otros o al rozar la pared interior de la caja del interruptor PRECAUCI N Aseg rese de que el suministro principal de electricidad est desconectado 5 Algunos motores de ventilador son sensibles a las se ales de los controles de velocidad de estado s lido variables Los controles de estado s lido no son recomendables Escoja un m todo de control alternativo 6 Aj
6. est n indicados para su uso con este producto podr a sufrir lesiones personales o da ar el ventilador ADVERTENCIA Este producto est dise ado para ser usado s lo con las piezas suministradas o los accesorios indicados especificamente para el mismo Si utiliza piezas o accesorios que no est n indicados para su uso con este producto podr a sufrir lesiones personales o da ar el ventilador ADVERTENCIA Para reducir el riesgo de lesiones personales no doble los soportes de las aspas borde o soporte de aspas al instala los soportes o limpiar el ventilador No coloque objetos extra os entre las aspas del ventilador en funcionamiento 1 Este equipo no causar interferencias perjudiciales y 2 este equipo tolerar cualquier interferencia recibida incluidas las interferencias que puedan provocar un funcionamiento no deseado Si el radiador intencional puede ser clasificado como un dispositivo digital de clase B o un perif rico del ordenador entonces se deber n incluir los siguientes o equivalentes Nota Tras someterlo a las pruebas correspondientes se ha determinado que este equipo cumple con los l mites establecidos para dispositivos digitales de Clase B de conformidad con la parte 15 de la Normativa FCC Estos l mites se han establecido con el objetivo de aportar una protecci n razonable contra interferencias perjudiciales cuando el equipo se utiliza en el hogar Este equipo genera utiliza y puede emitir energ a de radiofrecuencia
7. protectora Figura 5 Posici n de bloqueo El motor CC posee una funci n de seguridad integrada para evitar la obstrucci n de las palas Figura 5 durante el funcionamiento del ventilador Si algo obstruyera las palas del ventilador el motor dejar a de funcionar tas 30 segundos de interrupci n Extraiga los obst culos antes de restaurarlo Protecci n sobre 80 W Cuando el receptor detecta que el consumo de electricidad del motor supere los 80 W la fuente de alimentaci n del receptor se apagar y el ventilador dejar de funcionar Desconecte la fuente de alimentaci n y tras 5 segundos vuelva a encender el ventilador 30 C mo Reemplazar el Receptor 1 Retire la Cubierta de uni n del motor destornillando los dos tornillos Figura 1 a 2 Desconecte la antena la senal de cable y conector de 9 clavijasa continuacion remplace con el receptor nuevo Figura 2 senal de cable 7 gt gt E conector de lt 9 clavijas 3 Apretar los dos tornillos de la cubierta del motor de acoplamiento Figura 3 4 Tras instalar el nuevo receptor en su ventilador lleve a cabo el proceso de configuraci n del c digo en C mo utilizar su ventilador de techo Paso 3 de nuevo Mantenimiento El nico mantenimiento necesario para el ventilador de PRECAUCI N techo es una limpieza peri dica Al llevar a cabo la limpieza use s lo un cepillo suave o un No utilice solventes para limpiar el ventilador de
8. se encuentra en funcionamiento Instrucciones de seguridad adicionales Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles antes de realizar la instalaci n el ctrica y no haga funcionar el ventilador sin las aspas Todos los procedimientos de conexi n el ctrica e instalaci n deben cumplir con los C digos el ctricos nacionales ANSI NFPA 70 1999 y C digos locales El ventilador de techo debe estar conectado a tierra a fin de prevenir posibles descargas el ctricas La instalaci n el ctrica debe ser llevada a cabo o aprobada por un electricista autorizado Se debe fijar bien la base del ventilador sta debe ser capaz de soportar sin problemas al menos 22 73 kg 50 Ib Consulte la p gina 22 del manual del propietario para ver los requisitos de soporte Si tiene dudas consulte a un electricista calificado Las aspas del ventilador deben instalarse por lo menos a 2 m 7 pies del suelo a fin de evitar un contacto accidental con las mismas Siga las recomendaciones sobre el m todo correcto de instalaci n el ctrica de su ventilador de techo Si no posee la experiencia O los conocimientos el ctricos adecuados contrate a un electricista autorizado para instalar el ventilador ADVERTENCIA Este producto est dise ado para ser usado s lo con las piezas suministradas o los accesorios indicados espec ficamente para el mismo Si utiliza piezas o accesorios que no
9. se produzca un cierto movimiento oscilante y esto no debe considerarse un problema o defecto Tabla de contenidos Instrucciones para el desempaque 0 0coooooococccccrr o 21 C mo instalar las palas y el kit de luces 0 0 27 Uso eficiente de la energ a en ventiladores de techo 22 Como utilizar su ventilador de techo 0 0 0 0 29 Requisitos el ctricos y estructurales ooooommmo o 22 C mo Reemplazar el Receptor 00ooooocoocoocco 31 C mo ensamblar el ventilador de tech0 0 0 23 Mantenimiento EE EE sce econs neesanouecceeuase 31 C mo colgar el ventilador de tech0 0 00ocooooocoommmo 24 C mo limpiar su aspas del ventilador 31 C mo realizar la instalaci n el ctrica del ventilador de techo 25 Soluci n de problemas cusirinarias rencia vansker 32 C mo Instalaci n de la cubierta del capuch n 26 EE rn sacccucicesaeesanresersiuestenuescesseneenees 33 Ilustraci n del deSpiece 000oocooccocccocorro 34 20 Este manual est dise ado para facilitar al m ximo el ensamblaje la instalaci n el funcionamiento y el mantenimiento de su ventilador de techo Herramientas necesarias para el ensamblaje e Pelacables e Tres conectores de cables incluidos e Destornillador Phillips e Escalera de tijera e Destornillador de 1 4 A ADVERTENCIA Antes de ensambla
10. techo ERA descargas el ctricas No se requieren agentes abrasivos de limpieza los mismos deben evitarse para prevenir da os en el acabado SE RECOMIENDA verificar peri dicamente que los tornillos que sujetan los soportes de aspas al buje del motor est n bien ajustados Limpieza de las aspas Se recomienda limpiar el polvo de las aspas peri dicamente Evite usar agua productos de limpieza o trapos speros Lo mejor es utilizar un plumero que pueden combar o da ar las aspas 31 Soluci n de problemas ADVERTENCIA Para su propia seguridad desconecte la electricidad de la caja de fusibles o disyuntor antes de solucionar problemas en su ventilador Causa posible Soluci n sugerida 1 EL VENTILADOR NO ARRANCA 2 EL VENTILADOR HACE RUIDO 3 EL VENTILADOR OSCILA EN EXCESO 4 NO HAY SUFICIENTE MOVIMIENTO DE AIRE 1 El fusible o el disyuntor est n fundidos 2 Las conexiones el ctricas del ventilador o del interruptor en la caja del interruptor est n flojas 3 Sin bater a en el control remoto 1 Las aspas no est n sujetas al ventilador 2 Hay tornillos flojos en la caja del motor 3 Los tornillos que aseguran las aspas al buje del motor est n flojos 4 Los conectores de cables dentro de la caja hacen ruido 5 Ruido del motor provocado por el control de velocidad de estado s lido variable 6 Los tornillos que de aspas est n flojos 1 El tornillo de fijaci n y la tuerca
11. techo 4 GE Para evitar una posible descarga el ctrica no apriete N Pesta a Unidad del barral los cables entre el ensamble de la bola para colgar NOTA se amter scabies o peca y la abrazadera para colgar de suministro y los cables del ventilador para mayor claridad Figura 4 Aditamentos utilizados ABRAZADERA DEL CABLE DE SOPORTE DEL TECHO CON TORNILLO C mo realizar la instalaci n el ctrica del ventilador de techo 4 ADVERTENCIA Para evitar una posible descarga el ctrica aseg rese de cortar la alimentaci n el ctrica de la caja de fusibles principal antes de colgar el ventilador Figura 1 PRINCIPAL CAJA DE FUSIBLES On I On l On l HHR E Off O Off O O HO 0 40 BEE uo 1 UO 1 u0 NOTA Si no est seguro de si la caja de salida tiene conexi n a tierra pida consejo a un electricista certificado ya que debe tener conexi n a tierra para un funcionamiento Seguro 1 Conecte el conductor verde con conexi n a tierra de la bola para colgar y el conductor verde con conexi n a tierra de la abrazadera para colgar al conductor de On l H Off O 0 40 H UO Figura 1 Conductor verde suministro con conexi n a tierra posiblemente un puesta a tierra Gander conductor desnudo o un cable con aislante verde del suministro aja desalida Conecte los cables a los conectores provistos de forma COT SS homologada segura Conecte el conductor blanco del motor del
12. y a menos que se instale y se utilice de acuerdo con el manual de instrucciones puede provocar interferencias perjudiciales en las comunicaciones por radio y televisi n Si el equipo produce interferencias perjudiciales en la recepci n de radio o televisi n lo cual puede probarse encendiendo y apagando el equipo se recomienda al usuario corregir dichas interferencias tomando una o varias de las siguientes medidas Modificar la orientaci n o ubicaci n de la antena de recepci n Aumentar la separaci n entre el equipo y el receptor Conectar el equipo a una toma de corriente o circuito diferente al del receptor Consulte al distribuidor o a un t cnico especialista de radio o TV para obtener m s ayuda Nota Para un dispositivo digital de clase A la declaraci n de 15 105 a debe ser incluida cuando sea apropiada para el dispositivo en cuesti n GARANT A LIMITADA DE POR VIDA Se extiende al comprador original de un ventilador Fanimation GARANT A LIMITADA DE POR VIDA DEL MOTOR Si se produjera una falla en alguna de las partes del motor de su ventilador debido a un defecto en los materiales o en la fabricaci n durante el tiempo de vida del comprador original Fanimation proporcionar la pieza de repuesto sin cargo una vez que el ventilador defectuoso sea devuelto a nuestro centro de servicios nacional Se requiere comprobante de venta El cliente se har responsable de todos los gastos de remoci n o reinstalaci n y env o de
13. 0 vatios maximo Apague el interruptor de la pared y deje que la bombilla se enfrie durante 10 minutos antes de cambiar la bombilla La bombilla esta presurizada y puede hacerse a icos NO TOQUE LA BOMBILA CON LAS MANOS SIN PROTECCI N Las huellas dactilares pueden disminuir la vida til de la bombilla Elimine las huellas dactilares con alcohol antes de utilizar la bombilla HE 6 Monte el vidrio palo en la unidad de la placa del adaptador gir ndolo en el sentido de las agujas del reloj No apriete demasiado Figura 6A 6 1 Instale la tapa inferior de acero en la unidad de la placa del adaptador girandolo en el sentido de las agujas del reloj Figure 6B 28 Bombilla Minican de 100 W Ensamble de la placa del portalampara Figura 5A 42 Figura 6A Vidrio Figura 5B Unidad de la tapa inferior de acero Figura 6B C mo utilizar su ventilador de techo 1 Restaure la fuente de alimentaci n de la toma de corriente enciendo la electricidad del fusible principal Figura 1 A ADVERTENCIA PRINCIPAL CAJA DE FUSIBLES On l On l On l HH E Off O Off 0 E 0 H0 0 40 O 1 u0 1 UO 1 UO Compruebe que todas las conexiones realizadas correctamente incluyendo la toma de tierra y que no o e sLOs 8de O oO o Figura 1 se visualizan ningun cable pelado en los conectores de cables con la excepcion del cable de toma de tierra No utilice el ventilador hasta que las palas
14. 1 Remove the hanger ball portion from the downrod hangerball assembly by loosening the set screw in the hanger ball until the ball falls freely down the downrod Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 5 Figure 1 SET SCREW 2 Remove the hairpin clip and clevis pin from the bottom of downrod Retain the pin and clip for reinstallation in Step 4 Figure 2 HAIRPIN CLIP CLEVIS PIN 3 Loosen the two set screws in the downrod support gt BLACK BLUE AND Route black blue and white lead wires through the WHITE LEADS downrod Figure 3 4 Position downrod support and align the clevis pin SET SCREWS AND holes in both parts Install the clevis pin and secure AA with the hairpin clip Tighten the two set screws and locking nuts in the downrod support Figure 4 _ 5 Route wires through motor coupling cover canopy BLACK BLUE amp screw cover and canopy Figure 5 WHITE LEADS CANOPY COVER 6 Reinstall the hanger ball on the downrod as follows Route the three 80 inch wires through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin Securely tighten the set screw in the hanger ball A loose set screw could create fan wobble Figure 6 7 How to Assemble Your C
15. 2 Check line wire connections to fan and switch wire connections in the switch housings CAUTION Make sure main power is turned off 3 Replace with fresh battery 1 Fuse or circuit breaker blown 2 Loose power line connections to the fan or loose switch wire connections 1 FAN WILL in the switch housing NOT START Dead battery in remote control Blades not attached to fan Loose screws in motor housing Attach blades to fan before operating Check to make sure all screws in motor housing are snug not over tight Check to make sure the screws which attach the fan blades to the motor flywheel are tight Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to Screws securing fan blades to motor flywheel are loose 2 FAN SOUNDS NOISY Wire connectors inside housing rattling Motor noise caused by solid state 3 FAN WOBBLES EXCESSIVELY 4 NOT ENOUGH AIR MOVEMENT variable speed control Screws holding blades are loose Setscrew in downrod support is loose Setscrew in downrod hanger ball assembly is loose Screws securing fan blades to motor hub are loose Blades not seated properly Hanger bracket and or ceiling outlet box is not securely fastened 14 signals from solid st
16. E BOX A A 5 Off O Off O 0ff O sLUs 280 lt SLI 13 Figure 1 connectors except for the ground wire Do not operate fan until the blades are in place Noise and fan damage could result NOTE Receiver in controllers system features an automatic learning function There are no frequency switches on the receiver unit The receiver will automatically scan the frequency from the hand held control if an changes are made the frequency settings should be changed only in the case of interference or if multiple ceiling fans with the same type of control system are installed in the same structure Code Switches 2 To make fan operational install 23A 12V battery included in hand held remote transmitter with fan power off arrange code switches to desired code setting Then follow the remote code setting process If not used for long periods of time remove battery to prevent damage to transmitter Store the remote away from excessive heat or humidly Figure 2 3 Remote Control Setting and Speed RPM Setting Process Figure 3 1 After installing the unit and restoring power to your fan press and hold the SET button 1 5 seconds You must press the SET button within 60 seconds of restoring power to the fan 2 The fan will start to run and begin the control setting process The fan will run in both directions for a total of approximately 5 minutes 3 When the fan stops after approximately 5 mi
17. ING To avoid possible fire or shock make sure that the electrical wires are completely inside the canopy housing and not pinched between the housing and the ceiling Securely attach and tighten the canopy screw cover over the shoulder screws in the hanger bracket utilizing the keyslot twist lock feature Figure 2 SHOULDER SCREWS 2 Figure 2 How to Assemble the Blades and Light Kit 1 Position the blade over the motor assembly Make sure the blade is fully seated against the flywheel of Fer 0 motor assembly Tighten the 1 4 20 x 14 mm screws ES to secure the blade to the flywheel of motor assembly pe E 1 AN _ A n Figure 1 lt a TT Figure 1 HARDWARE USED 1 4 20 x 14 mm SCREWS 2 Remove one of the three screws in the support bracket of motor assembly Slightly loosen the remaining two screws Assemble the light plate assembly to the motor assembly using the two key slots Replace the third screw and securely tighten all three screws Figure 2 ASSEMBLY MOTOR ASSEMBLY Figure 2 3 Connect the 2 single pin connector from the light socket plate to 2 single pin connector from motor assembly Figure 3 CAUTION To reduce the risk of electric shock disconnect the electrical supply circuit to the fan before installing light kit MOTOR ASSEMBLY 7 SOCKET PLATE EZ ASSEMBLY Figure 3 4 Remove one of the three screws in the light plate assembly Slightly loosen th
18. NE YEAR MOTOR LABOR WARRANTY If your fan motor fails at any time within one year from the original purchase due to defects in materials or workmanship labor to repair the motor will be provided free of charge at our national service center Purchaser will be responsible for labor charges after this one year period Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement If any other part of your fan fails at any time within one year after original purchase due to a defect in materials or workmanship we will repair or replace at our option the defective part free of charge for parts and labor performed at our national service center Because of varying climate conditions this warranty does not cover changes in the finish including rusting pitting corroding tarnishing or peeling This warranty is void and does not apply to damage from improper installation neglect accident misuse exposure to extremes of heat or humidity or as a result of any modification to the original product All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan or Fanimation Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty Under no circumstances may a fan be returned without prior authorization from Fanimatio
19. NOTE SUPPLY WIRES AND FAN h BALL ASSEMBLY WIRES OMITTED FOR CLARITY Fiqure 4 cable clamp onto safety cable from fan Place the end igure of cable through the loop of ceiling support cable Pull as much cable through loop as possible Feed end of cable into clamp hole and firmly tighten screw Figure 4 HARDWARE USED CEILING SUPPORT CABLE CLAMP W SCREW How to Wire Your Ceiling Fan ay WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before hanging Figure 1 MAIN FUSE BOX On I On l On l HH H E Off O Off O O HO 0 40 BHG YO 1 4O I 4O On l E Off O 0 40 H I 40 NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation Figure 1 a 1 Connect the green grounding lead from the downrod hanger ball assembly and the green grounding lead from the hanger bracket to the supply f i i Green Wire grounding conductor this may be a bare wire or wire from Supply White Wire with green colored insulation Securely connect wires Ground from Supply Tr with wire connectors Securely connect the white fan Outlet Box motor wire to the white supply neutral wire using wire connector Securely connect the black fan motor wire to the black supply wire using wire connector Household Supply Black Wire Figure 2 Green Wire L
20. The J ennix Ceiling Fan Net Weight 24 68lbs 11 21 kg Model No FPD7943 OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Important Safety Instructions WARNING To avoid fire shock and serious personal injury follow these instructions Read your owner s manual and safety information before installing your new fan Review the accompanying assembly diagrams Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not insert anything into the fan blades while the fan is operating Additional Safety Instructions To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring and installation procedures must satisfy National Electrical Codes ANSI NFPA 70 1999 and Local Codes The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The fan base must be securely mounted and capable of reliably supporting at least 50 Ibs fan and accessories not to exceed
21. arilla ornillo de fijacion y de la clavija de horquilla en ambas piezas Instale la EE tuercas 2 clavija de horquilla y asegurela con la pinza de horquilla Fije los dos tornillos de presi n y las tuercas de seguridad en el soporte de la varilla interior Figura 4 5 Pase los cables a trav s de la cubierta de uni n del re motor la cubierta para el tornillo y el capuchon Blanco lleva Figura 5 La cubierta del tornillo de la base 6 Vuelva a colocar la semiesfera en el barral como se indica a continuacion Pase los tres cables de deal Capuch n de techo 2 03 m 80 a trav s de la semiesfera Pase el pasador spm y fr SP ae a traves de los dos orificios en el barral y alinee la semiesfera de modo que el pasador quede atrapado en la ranura de la parte superior de la misma Empuje la semiesfera hacia arriba bien ajustada contra el Bola para colgar pasador Ajuste firmemente el tornillo de fijacion en la semiesfera Si el tornillo de fijacion esta flojo podria provocar oscilacion del ventilador Figura 6 fijacion 23 C mo ensamblar el ventilador de techo cont 7 Corte el exceso de cable aproximadamente de 15 a 23 cm 6 a 9 pulgadas por encima de la parte superior del barral Pele 1 2 cm 125 del aislamiento en cada extremo del cable Figura 7 NOTA Se deben revisar todos los tornillos de fijaci n y volver a ajustarlos cuando sea necesario antes de realizar la instalaci n A ADVERTENCIA
22. ate variable speed controls Solid state controls are not recommended choose an alternative control method Tighten screws securely Tighten both setscrews securely in downrod support Tighten the setscrew in the downrod hanger ball assembly Check to be sure screws which attach the fan blades to the flywheel are tight Check to be sure the fan blades seat firmly and uniformly to the surface of the motor housing If blades are seated incorrectly loosen the screws and retighten Tighten the hanger bracket screws to the outlet box and secure outlet box If possible consider using a longer downrod For example use a 12 downrod instead of the 4 downrod that comes with your fan Parts List Model No FPD7943 Ref Description Part AP255BL ADRT 45 IES AP260 AP1115 AMA7943 AP794306 AP794310 PPE11B100 10 P7943077 11 Blade Set AP794303 12 TR29 13 AP794309 Bag Assembly Loose Parts HDWFP7943 Wire Connector 4 4 Phillips Head Screwdrive Pan Head Screw 1 4 20 x 14mm 7 Bag Assembly Safety Cable Insert FINISH CODES Refer to fan model number located on downrod support Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS When ordering repair parts always give the following information e Part Number e Part Description e Fan Model Number Contact your retail store for repair par
23. bly Remote A I Fan Motor Assembly Ceiling Canopy Hardware Bags Canopy Screw Cover Blade Set Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure efficient product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Fanimation Retailer for optional mounting accessories Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy Using the Ceiling Fan Year Round Summer Season Use the ceiling fan in the counterclockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy Winter Season Reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Electrical and Struc
24. e remaining two screws Assemble the socket plate to the light plate assembly using the two key slots Replace the third screw and securely tighten all three screws Figure 4 Socket Pla Light Plate Assembly Assembly Figure 4 10 5 Install included minican bulb into the socket Figure 5A 5 1 Don t install the light bulbs if you want to install the lower steel cap in Step 6 1 Figure 5B CAUTION To reduce the risk of fire use 100 watt max type T4 minican JD E11 tungsten halogen bulb Turn off the wall switch and allow the bulb to cool for 10 minutes before relamping Bulb is pressurized and may shatter DO NOT TOUCH BULB WITH BARE HANDS Fingerprints may result in shorter bulb life Remove fingerprints with alcohol prior to use 6 Secure the glass to the light plate assembly by twisting in a clockwise direction Do not over tighten Figure 6A 6 1 Assemble the lower steel cap to the adapter plate assembly by twisting in a clockwise direction Figure 6B 11 Minican Light Bulg SOCKET PLATE ASSEMBLY Figure 5A Figure 5B LOWER STEEL GLASS CAP ASSEMBLY Figure 6A Figure 6B How to Operate Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box Figure 1 WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire 1 u0 1 UO I 4O I 4O MAIN FUS
25. eiling Fan continued Cut off excess lead wire approximately 6 to 9 inches above top of the top of the downrod Strip insulation off 1 2 inch from the end of each lead wire Figure 7 NOTE All set screws must be checked and retightened where necessary before installation How to Hang Your Ceiling Fan WARNING To avoid possible fire or shock be sure electricity is turned off at the main fuse box before hanging Figure 1 NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advise as it must be grounded for safe operation WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 2 _ 1 Securely attach the hanger bracket to the outlet box using the outlet box screws and washers supplied with the outlet box Figure 2 2 Drill a Y pilot hole into the building structure to prevent splitting or cracking with installation of the lag bolt Using the 3 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop and into the building structure Figure 3 NOTE Ceiling support cable cannot be secured to junction box only it must be directly secured to ceiling joist or structural member using the 3 x 2 lag bolt and flat washer Figure 3 3 Make sure the electrical supply wires including the hanger bracket gr
26. el derecho de modificar o discontinuar un producto en cualquier momento o sustituir cualquier pieza seg n lo establecido por esta garant a En ning n caso se podr devolver un ventilador sin previa autorizaci n por parte de Fanimation Las devoluciones autorizadas deber n ir acompa adas del recibo de venta y deber n enviarse a Fanimation previo pago del flete El ventilador que se devuelva deber estar embalado en forma adecuada a fin de evitar da os durante el transporte Fanimation no se har responsable de los da os que resulten del embalaje incorrecto del producto 19 GARANT A LIMITADA DE POR VIDA Se extiende al comprador original de un ventilador Fanimation 9 Se entiende que las reparaciones y las sustituciones son el nico recurso disponible de Fanimation No existe ninguna otra garant a expresa o impl cita Por la presente Fanimation niega todas las garant as impl citas que incluyen entre otras la comerciabilidad y la aptitud para determinado fin hasta donde la ley lo permita Algunos estados no permiten limitaciones sobre las garant as impl citas Fanimation no se har responsable por da os accidentales resultantes o especiales derivados del uso o el rendimiento del producto o en conjunci n con ste excepto en los casos en los que la ley as lo disponga Esta garant a le otorga derechos legales especiales y es posible que tambi n goce de otros derechos que pueden variar seg n el estado 10 Es normal que
27. embro 7 estructural con el tornillo de cabeza cuadrada de Xx2 y VL LILL LAG SSS So la arandela plana Figura 3 Tesia LE gt 3 Aseg rese de que los cables de suministro el ctrico Caja de incluido el cable de conexi n a tierra del soporte de conexiones I dl suspensi n y el cable de seguridad hayan atravesado el Saleda AS barral entre el soporte de suspensi n y la caja de soporte SS A conexiones de modo que m s tarde se pueda realizar la para echa Figura 3 instalaci n el ctrica ADVERTENCIA La caja de salida debe estar bien asegurada La abrazadera para colgar debe estar bien asentada contra la caja de salida Si la caja de salida est empotrada retire el panel hasta que la abrazadera haga contacto con la caja Si la abrazadera y o la caja de salida no est n bien aseguradas el ventilador podr a tambalearse o caerse 24 C mo colgar el ventilador de techo we 4 Levante cuidadosamente el ventilador y coloque el NE ensamble de la bola para colgar varilla en la abrazadera z EY para colgar que acaba de fijar a la caja de salida oe Asegurese de que la ranura de la bola este alineada con la lengueta de la abrazadera para colgar Figura 4 VIT LLL A ADVERTENCIA Y CN SSS Sry Si no coloca la leng eta en la ranura podr an da arse los cables el ctricos y podr an ocurrir Fije el cable incendios o descargas el ctricas de seguridad al cable de SN soporte para ADVERTENCIA J
28. er ooooooooooooommmmomo 13 How to Assemble Your Ceiling Fan 6 EE TE Te xcsvicrsrarcencir rr dee da whew eciad 13 How to Hang Your Ceiling Fan 0 o ooooooooooo 7 How to Clean Your Ceiling Fan Blades 13 How to Wire Your Ceiling Fan 0oooooooooooooo 8 Trouble Shooting lt lt oooooonnnnnaaaaaaans 14 How to Install Your Canopy Housing o o o 9 PASSE Leseren 15 Exploded View Illustration 00 oooooo o 16 This manual is designed to make it as easy as possible for you to assemble install operate and maintain your ceiling fan Tools Needed for Assembly Materials e One Phillips head screwdriver e One wire stripper Wiring outlet box and box connectors must be of type e One stepladder e One 1 4 blade required by the local code The minimum wire would be a e Three wire connectors supplied screwdriver 3 conductor 2 wire with ground of the following size Installed Wire Length Wire Size A W G Up to 50 ft 14 da WARNING 50 100 ft 12 Before assembling your ceiling fan refer to section on proper method of wiring your fan page 8 If you NOTE Place the parts from the loose parts bags in a small feel you do not have enough wiring knowledge or container to keep them from being lost If any parts are experience have your fan installed by a licensed missing contact your local retailer electrician Unpacking Instructions F
29. es de embalaje aseg rese de haber extra do todas las piezas C mo hacer un pedido de piezas Al hacer un pedido de piezas de repuesto proporcione siempre la siguiente informaci n e N mero de pieza e Descripci n de la pieza ___ N mero de modelo del ventilador P ngase en contacto con su tienda para obtener las piezas de repuesto 33 FPD 943 Despiece NOTA La ilustraci n que se muestra no est hecha a escala y su configuraci n real o las terminaciones puede variar 34 FANIMATION CEILING FANS 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Copyright 2012 Fanimation Visite nuestro sitio Web en www fanimation com 2012 07 V 01
30. est n colocadas en su lugar ya que de lo contrario se podria causar ruido y danos NOTA El receptor del sistema de los controladores se caracteriza por la funci n de aprendizaje autom tico No hay interruptores de frecuencia en la unidad del receptor El receptor ya que se escanear autom ticamente la frecuencia desde el mando a distancia Si se realiza cualquier cambio Los ajustes de frecuencia deben C digo Interruptores modificarse solo en el caso de interferencia o si m ltiples ventiladores con el mismo sistema de control son instalados en la misma estructura 2 Para que el ventilador sea functional instale las pilas incluidas de 23A 12V en el transmisor del mando a distancia Mientras el ventilador este apagado A continuaci n siga el proceso de fijaci n remota de c digo Si no se utiliza el ventilador durante un largo periodo de tiempo extraiga la bater a para evitar cualquier da o al transmisor Almacene el mando a distancia en un lugar alejado del calor o la humedad excesiva Figrua 2 3 Configuraci n del mando a distancia y proceso de configuraci n de la velocidad RPM Figura 3 1 Tras instalar la unidad y restaurar la electricidad a su ventilador mantenga pulsado el bot n SET Configurar durante 1 5 segundos Debe pulsar el bot n SET durante los 60 segundos despu s de la restauraci n de la electricidad al ventilador 2 El ventilador comenzar a funcionar e iniciar el p
31. ion para usar con este producto podr a ocasionar lesiones personales o da os en el ventilador P ngase en contacto con su tienda si faltan piezas o hay piezas da adas 1 Verifique que haya recibido las siguientes piezas NOTA Si no est seguro de la descripci n de una pieza consulte la ilustraci n del despiece Unidad del soporte de suspensi n Cubierta de uni n del motor Unidad del barral de la semiesfera Unidad del motor del ventilador E Capuch n de techo Cubierta para el tornillo del capuch n e Bolsa de accesorios 1 4 20 x 14 mm aspas en el motor e Unidad del motor del ventilador e Unidad del soporte de suspensi n e Unidad del barral de la tornillo de cabeza troncoc nica semiesfera Destornillador Phillips de 4 e Capuch n de techo e Cubierta para el tornillo del capuch n e Cubierta de uni n del motor e Juego de aspas e Ensamble de la placa de iluminaci n e Ensamble de la placa del portal mpara e Vidrio e Unidad de la tapa inferior de acero e TR29 De mano a distancia e Bombilla Cuatro conectores de los cables Cable de seguridad y Bolsa Bombilla Minican Ensamble de la placa del portal mpara N Y TR29 De mano a distancia Unidad de la tapa inferior de acero Vidrio Bolsas de accesorios Uso eficiente de la energ a en ventiladores de techo El nivel de rendimiento y ahorro de energ a de los ventiladores de techo dependen de
32. l producto para reparaciones o sustituci n GARANT A DE MANO DE OBRA DEL MOTOR POR UN ANO Si el motor de su ventilador fallara antes de cumplirse un a o a partir del momento de su compra original debido a defectos en los materiales o en la fabricaci n se le efectuar la reparaci n del mismo sin cargo en nuestro centro de servicios nacional El comprador se har responsable de los gastos de mano de obra luego del per odo de un a o El cliente se har responsable de todos los gastos de remoci n o reinstalaci n y env o del producto para reparaciones o sustituci n Si otra pieza del ventilador fallara dentro del per odo de un a o a partir de la fecha de compra original debido a un defecto en los materiales o en la fabricaci n repararemos o sustituiremos seg n creamos conveniente la pieza defectuosa sin cargo alguno en nuestro centro de servicios nacional Debido a las diversas condiciones clim ticas esta garant a no cubre cambios en la terminaci n incluidos oxidaci n corrosi n falta de brillo o peladuras Esta garant a es nula y no se aplica a da os por instalaci n incorrecta negligencia accidentes uso indebido exposici n al calor o a la humedad en exceso o como resultado de cualquier modificaci n realizada al producto original Todos los gastos de remoci n y reinstalaci n del ventilador son responsabilidad exclusiva del propietario y no de la tienda que vendi el ventilador ni de Fanimation Fanimation se reserva
33. lanco del gt el ctrico ventilador Conductor negro Conductor verde 2 del suministro de la abrazadera E para colgar puesta a tierra Conductor verde de la bola Conductor negro para colgar del ventilador puesta a tierra Figura 3 C mo instalar la carcasa de la cubierta 1 Retire uno de los dos tornillos de reborde de la abrazadera para colgar Afloje el segundo tornillo de reborde sin retirarlo del todo Ensamble la base girando el chavetero de la base sobre el tornillo de reborde de la abrazadera para colgar Ajuste el tornillo de reborde Ensamble por completo el segundo tornillo y a Si Tornillo de reborde que antes hab a retirado y aj stelo de fijaci n 2 Figura 1 ADVERTENCIA Para evitar posibles incendios o descargas el ctricas aseg rese de que los cables el ctricos se encuentren completamente adentro de la cubierta del capuch n y de que no est n aprisionados entre la cubierta y el tec 2 Coloque y ajuste firmemente la cubierta para el tornillo de la base sobre los tornillos de reborde de la abrazadera para colgar mediante el mecanismo de seguro por giro del chavetero Figura 2 Cubierta para el tornillo del capuch n Figura 2 26 ME 2 Retire uno de los tres tornillos de la abrazadera BE PRECAUCI N A fin de reducir el riesgo descargas el ctricas 4 Extraiga uno de los tres tornillos de la unidad de la placa Afloje levemente los otros dos tornil
34. los Instale la placa de conexi n en la unidad de la C mo instalar las Palas y el Kit de luces Coloque el aspa en el ensamble del motor Aseg rese de del aspa est completamente asentado sobre el volante del ensamble del motor Apriete los tornillos con el aspa al volante del ensamble del motor Figura 1 de soporte Afloje ligeramente los dos tornillos restantes Instale la Unidad de placa de luces a la motor utilizando las dos ranuras principales de la placa de conexi n Vuelva a colocar el tercer tornillo y asegure los tres tornillos Figura 2 Instale el conector de 2 clavijas desde la placa de conexi n a la unidad del motor Figura 3 desconecte el circuito de suministro el ctrico al ventilador antes de instalar el kit de iluminaci n placa de luz utilizando las dos ranuras princi pales Vuelva a colocar el tercer tornillo y asegure los tres tornillos Figura 4 27 Volante Aditamentos utilizados hon TORNILLOS DE 1 4 20 x 14 mm Ensamble de la placa Ensamble de iluminaci n del motor Figura 2 Ensamble del motor Tay Ensamble de la placa del Figura 3 portal mpara Tornillos 3 La conexi n Ensamble de la placa de iluminaci n Figura 4 5 1 No instale las bombillas si desea montar la tapa inferior de acero en el Paso 6 1 Figura 5B PRECAUCION Para reducir el riesgo de incendios utilice la bombilla halogena tungsteno de tipo T4 minican JD E11 de 10
35. n The receipt of purchase must accompany authorized returns and must be sent freight prepaid to Fanimation The fan to be returned must be properly packed to avoid damage in transit Fanimation will not be responsible for any damage resulting from improper packaging LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan 9 It is understood that any repair or replacement is the exclusive remedy available from Fanimation There is no other expressed or implied warranty Fanimation hereby disclaims any and all implied warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law Some states do not allow limitations on implied warranties Fanimation will not be liable for incidental consequential or special damages arising out of or in conjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect Table of Contents Unpacking INSIFUCHONS a ao arena pana paa wae 4 How to Assembly the Blades amp Light Kit 10 Energy Efficient Use of Ceiling Fans 5 How to Operate Your Ceiling Fan oooo 12 Electrical and Structural Requirements 5 How to Replace Receiv
36. ncillo paso puede ahorrar energ a adicional y dinero Requisitos el ctricos y estructurales Su nuevo ventilador de techo requiere una l nea de suministro el ctrico con conexi n a tierra de 120 voltios de CA 60 Hz circuito de 15 amperios La caja de distribuci n el ctrica debe estar bien asegurada y debe ser capaz de soportar una carga de al menos 22 7 kg 50 Ib La Figura 1 muestra diversas configuraciones estructurales que podr an utilizarse para montar la caja de distribuci n el ctrica A ADVERTENCIA Para reducir el riesgo de incendios descargas el ctricas o lesiones personales fije el ventilador a la caja de distribuci n el ctrica marcada como aceptable para un peso Utilice los tornillos suministrados con la caja de distribuci n el ctrica La mayor a de las cajas de distribuci n el ctricas que com nmente se utilizan como soporte de l mparas no sirven como soporte de ventiladores y es posible que deban reemplazarse Consulte a un electricista calificado si tiene dudas Si el ventilador reemplazar a una l mpara existente desconecte la electricidad de la caja de fusibles principal y retire la l mpara A ADVERTENCIA Apagar el interruptor de pared no es suficiente Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles principal antes de realizar la instalaci n el ctrica Toda instalaci n el ctrica debe cumplir con los c digo
37. nutes the control and speed setting process is complete The fan is now ready for normal use NOTE If you want to change the blades turn the off change the blades turn the power on gt replay the power setting process a 4 The remote buttons instruct as below e Fan speed minimum speed Il low speed Ill medium low speed IV medium speed V medium high speed VI high speed e Button This button turns the fan off e 2 Reverse button This button is to control fan direction e AR Light button The button is to control light Infinite light levels are available by holding the light on off button Figure 4 Figure 4 12 How to Operate Y our Ceiling Fan Continued 5 D and ON dip switch The ON selection is the light dimmable selection and is to be used with all bulbs other than CFL The D selection is the light on only no dimming function and is to be used ON ECE with CFL bulbs as CFL bulbs cannot be dimmed The receiver provides the following protective function Code Switches Figure 5 Lock position The DC motor has a built in safety feature against blade obstruction against obstruction during operation If something obstructs the fan blades the motor Figure 5 will stop operating after 30 seconds of interruption Please remove obstacles and reset Over 80W protection When the receiver detects motor power consumption which is grea
38. or your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted a WARNING e Fan Motor Assembly e Hardware bags Hanger Bracket Assembly with 1 4 20 x 14mm blade to motor Do not install or use fan if any part is damaged or screws Bar Head Screw missing This product IS designed to use only those e Downrod Hanger Ball Assembly Phillips Screwdriver 4 parts supplied with this product and or any accessories designated specifically for use with this product by Fanimation Substitution of parts or accessories not designated for use with this product e Ceiling Canopy e Canopy Screw Cover Assembly e Motor Coupling Cover Assembly Four Wire Connectors Bag Assembly Safety Cable by Fanimation could result in personal injury or Blade Set property damage Contact your retail store for Light Plate Assembly missing or damaged parts e Socket Plate Assembly e Glass 1 Check to see that you have received the following parts Lower Steel Cap Assembly e TR29 Hand held Remote NOTE If you are uncertain of part description refer to Bulb exploded view illustration CTD Hanger Bracket Minican Bulb Assembly 100W W Screws Motor Coupling Cover Assembly OFF Downrod a Socket Plate Assembly G_1 Hanger Ball TR29 Hand held Assem
39. ounding wire and safety cable are pulled through the downrod between the hanger bracket and the junction box so that electrical connections can be made later WARNING The outlet box must be securely anchored Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall On l On On l HHR E Off O Off O O HO 0 40 BHG 1 u0 YO 1 40 MAIN FUSE BOX On l H Off O 0 40 E 1 40 Figure 1 FLOOR Figure 2 WOOD MEMBER TITT Y UNA WY g te CEILING JUNCTION BOX CEILING SUPPORT CABLE HANGER BRACKET How to Hang Y our Ceiling Fan continued 4 Carefully lift the fan and seat the downrod hanger ball E SET NE Q s assembly on the hanger bracket that was just attached to YEO NG 4 the outlet box Be sure the groove in the ball is lined up oe with tab on the hanger bracket Figure 4 LL Le WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard Ne ard ATTACH SAFETY __ BT IIN CABLE TO CEILING S SUPPORT CABLE Se SP i NY WARNING S SI RF N To avoid possible shock do not pinch wires between the hanger ball assembly and the hanger bracket E 1 T DOWNROD HANGER C 5 Attach the safety cable to ceiling support cable Slide
40. r el ventilador de techo consulte la secci n sobre el m todo correcto de instalaci n el ctrica del ventilador p gina 25 Si siente que no posee la experiencia o los conocimientos el ctricos necesarios contrate a un electricista autorizado para instalar el ventilador Materiales La caja de distribucion el ctrica y los conectores de la caja deben ser del tipo requerido por el c digo local El cable mas peque o debe ser un cable de tres conductores de dos conductores con conexi n a tierra del siguiente tama o tama o del cable seg n el A W G longitud del cable instalado Calibre de Alambre Estadounidense hasta 15 2 m 50 pies 14 de 15 2 a 30 5 m 50 a 100 pies 12 NOTA coloque las piezas de las bolsas de piezas individuales en un contenedor peque o para evitar que se extravien Si faltan piezas p n gase en contacto con su proveedor local Instrucciones para el desempaque Para su comodidad marque cada uno de los pasos medida que completa cada paso coloque una marca de verificaci n Con esto se asegurar de completar todos los pasos y podr saber desde d nde retomar si fuera interrumpido A ADVERTENCIA No instale ni utilice el ventilador si falta alguna pieza o si hay piezas da adas Este producto est dise ado para ser usado s lo con las piezas suministradas o los accesorios indicados por Fanimation especificamente para el mismo La sustituci n de piezas o accesorios no designados por Fanimat
41. roceso de configuraci n del control El ventilador funcionar en ambas direcciones durante un total de 5 minutos aproximadamente 3 Cuando el ventilador deje de funcionar despu s de 5 minutos aproximadamente se habr completado el proceso de configuraci n del control y la velocidad NOTA Si desea cambiar las palas apague el dispositivo cambie las palas repetir el proceso de establecimiento de El ventilador ya est listo para su uso normal 29 C mo utilizar su ventilador de techo cont 4 Los botones del mando a distancia se describen a continuaci n e Velocidad del ventilador Velocidad minima Il Velocidad baja Ill Velocidad medio baja IV Velocidad media V Velocidad medio alta VI Velocidad alta e EW Bot n Este bot n apaga el ventilador e Bot n Invertir Parte posterior del mando a Figura 4 distancia Este bot n controla la direcci n del ventilador e AK Bot n Luz Este bot n controla la luz y niveles de luz infinitos est n disponibles manteniendo pulsado el bot n de Encendido Apagado de la luz Figura 4 5 Conmutador D y ON La selecci n ON es la selecci n regulable de luz y debe ser utilizada con todas las bombillas menos con las bombillas CFL La selecci n D es la encender solo la luz sin la funci n de regulaci n y debe ser utilizada con bombillas CFL ya que estas no pueden ser reguladas El receptor ofrece la siguiente funci n
42. s nacionales y locales y el ventilador de techo debe tener la conexi n a tierra adecuada como forma de precauci n ante posibles descargas el ctricas 22 Vigas del 27 x 4 Caja de distribucion Figura 1 el ctrica A ADVERTENCIA A fin de evitar incendios o descargas el ctricas siga con cuidado todas las instrucciones de instalaci n el ctrica Cualquier trabajo el ctrico que no se describa en estas instrucciones deber ser realizado o aprobado por un electricista autorizado C mo ensamblar el ventilador de techo 1 Extraiga la pieza de la bola colgante de la unidad de la bola colgante varilla aflojando el tornillo de presion de la bola colgante hasta que la bola se libere de la varilla Retire el pasador del barral y luego extraiga la semiesfera Conserve el pasador y la semiesfera para su reinstalaci n en el Paso 5 Figura 1 Tornillo de fijaci n Ranura de la bola colgante Bola para colgar Figura 1 2 Retire el clip de horquilla y pasador de horquilla de la parte inferior de la bola para colgar Retener el pasador y clip para la reinstalacion en el paso 4 Figura 2 Pasador de Horquilla horquilla El 3 Afloje los dos tornillos de fijaci n del soporte del barral Introduzca los cables de color negro azul y blanco a Blanco lleva trav s de la varilla Figura 3 Soporte de la varilla 4 Coloque el soporte de la varilla y alinee los orificios ae i La V
43. su correcta instalaci n yuso A continuaci n le presentamos algunas sugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habitaci n a 2 m 7 pies de altura del piso como m nimo y 0 5 m 18 pulgadas de las paredes Si la altura del techo lo permite instale el ventilador a 2 5 m 8 9 pies por encima del suelo para un flujo de aire ptimo Consulte en su tienda minorista de Fanimation para obtener accesorios de montaje opcionales Apague el ventilador cuando no se encuentre en la habitaci n Los ventiladores son para refrescar a la gente no a las habitaciones Si la habitaci n est vac a apague el ventilador de techo para ahorrar energ a Uso del ventilador de techo todo el a o En verano Use el ventilador de techo en sentido contrario a las agujas del reloj El flujo de aire que produce el ventilador crear un efecto fr o del aire que lo refrescar m s Seleccione una velocidad que le proporcione una brisa confortable Las velocidades m s bajas consumen menos energ a En invierno Invierta el motor y haga funcionar el ventilador de techo a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que obliga al aire c lido que se acumula cerca del techo a bajar al espacio ocupado No olvide ajustar el termostato cuando utilice el ventilador de techo Con este se
44. ter than 80W the receiver power will shutdown and fan operation will cease Disconnect the power supply and after 5 seconds return power on to the fan How to Replace Receiver 1 Remove cover housing upper by unscrewing the two screws Figure 1 Cover Housing 2 Unplug signal wire and 9 pin connector than replace new receiver Figure 2 3 Tight the two screws from the cover housing upper Figrue 3 4 After installing new receiver to your fan operate the remote Code Setting process on How to operate your ceiling fan Step 3 again Maintenance 1 Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use CAUTION only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shock How to Clean Your Ceiling Fan Blades Periodic light dusting ot the blades is recommended Avoid using water cleansers or harsh rags which A feather duster will work best can warp and ruin the finish 13 Trouble Shooting 44 WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan Trouble Probable Cause Suggested Remedy 1 Check main and branch circuit fuses or circuit breakers
45. to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note For a Class A digital device statements of 15 105 a must be included when appropriate for the device in question LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan LIMITED LIFETIME MOTOR WARRANTY If any part of your fan motor fails due to a defect in materials or workmanship during the lifetime of the original purchaser Fanimation will provide the replacement part free of charge when the defective fan is returned to our national service center Proof of purchase is required Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement O
46. ts FPD7943 Exploded View NOTE The illustration shown is not to scale or its actual configurations may vary 16 FANIMATION CEILING FAN S 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Fanimation Website www fanimation com Copyright 2012 2012 07 V 01 The Jennix Ventilador de techo Peso neto 24 68 Ib 11 21 kg Modelo N FP7943 MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Instrucciones de seguridad importantes ADVERTENCIA Siga estas instrucciones para prevenir incendios descargas el ctricas y lesiones personales graves Lea el manual del propietario y la informaci n de seguridad antes de instalar su nuevo ventilador Observe los diagramas de ensamblaje adjuntos Antes de llevar a cabo el mantenimiento o la limpieza de la unidad desconecte la electricidad en el panel de servicio y bloquee los medios de desconexi n del mismo para evitar que se active accidentalmente Si no se pueden bloquear los medios de desconexi n del servicio coloque un dispositivo de advertencia como una etiqueta en el panel de servicio Tenga cuidado con la estructura y las aspas del ventilador cuando limpie pinte o trabaje cerca del mismo Desconecte siempre la electricidad del ventilador de techo antes de llevar a cabo el mantenimiento No coloque nada en las aspas del ventilador cuando ste
47. tural Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 Ibs Figure 1 depicts different structural configurations that may be used for mounting the outlet box A WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked acceptable for fan support Use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture 4 WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock CEILING JOIST OUTLET BOX Figure 1 WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician How to Assemble Your Ceiling Fan
48. uste bien los tornillos 1 Ajuste bien los dos tornillos de fijaci n y las tuercas en el soporte de barral 2 Ajuste el tornillo de fijaci n en la unidad del barral de la semiesfera 3 Aseg rese de que los tornillos que fijan los aspas al buje del motor del ventilador est n bien ajustados 4 Aseg rese de que los aspas del ventilador est n colocados firmemente y de manera uniforme en relaci n con la superficie de la caja del motor Si los aspas est n mal colocados afloje los tornillos y vuelva a ajustarlos 5 Ajuste los tornillos del soporte de suspensi n de la caja de distribuci n el ctrica y aseg rela 1 Si es posible considere el uso de un barral m s largo Por ejemplo use un barral de 30 5 cm 12 en lugar del barral de 11 4 cm 4 1 2 que viene con el ventilador Lista de piezas Modelos N FPD7943 N de Ref Descripci n Pieza 4 N AP255BL ADR1 45 PG154 AP260 AP115 AMA7943 AP794310 PPE11B100 P7943077 AP794303 TRAWH Unidad de la tapa inferior de acero AP794309 Bolsa de accesorios HDWFP7943 Conectores de los cables 4 Destornillador Phillips de 4 1 4 20 x 14 mm aspas en el motor tornillo de cabeza troncoc nica Cable de seguridad y Bolsa Ensamble de la placa de iluminaci n AP794306 Inserte los C DIGOS DE ACABADO consulte el n mero de modelo del ventilador que se encuentra en el soporte de barral Antes de desechar los material

Download Pdf Manuals

image

Related Search

Related Contents

Alle Auswerteeinheiten Installationsanleitungen 1,9 MB  Catalogue Modélisme  Philips DLP5260  リリース全文(PDF:715KB)  Bedienungsanleitung (D) Operating instructions  Massive Ceiling light 30190/17/17  BDL3220QL - VideoTesty.pl  V7 CAT6 UTP Network Cable 3 (RJ45m/m) black 3m  DRM Software Radio PC based software for DRM reception User  iogear GUC2025HD  