Home

MS-12TE / MS-12FE

image

Contents

1. ADJUSTABLE 90 AJUSTABLE 90 o VARIABLE 180 SS SS SSS DETECTION MODE OR MODO DE ON OR 33 DETECCI N OR 33 40 12m UPPER SENSOR COVERAGE Fine Adjustment Ajuste de precision TOP VIEW VISTA SUPERIOR Wall Detection Detecci n de pared DETECTION MODE OR MODO DE DETECCI N OR Masking unnecessary zones Enmascarando zonas innecesarias Horizontal Zone Zona horizontal 3 3 SIDE view 0 VISTA LATERAL 0 Variable range Rango variable Downward Zone Zona baja Detection distance is set by adjusting the angle of downward zone Adjustable range 6 6 2m to 40 12m 10 ranges Distancia de detecci n ajustada por el ajuste del ngulo de la zona baja Rango ajustable de 6 6 2 m a 40 12 m 10 rangos DETECTION DISTANCE ADJUSTMENT es AJUSTE DE LA DISTANCIA DE DETECCION Area of little temperature difference ex hot summer Area con poca diferencia de temperatura ej Th A 7 S verano caluroso a Short distance a A detection EE Detection Distancia de iS SSSR Detecci n detecci n corta Index Indice Detect human body Detecta cuerpo humano Long distance detection Area of big temperature difference ex cold Distancia de Adjustment lever winter detecci n larga Palanca de ajuste rea de gran diferencia de temperatura ej Detect vehicles invierno fr
2. L A e Lights at alarm ON o ON e Light flickers during warm up period Factory set e Se ilumina durante la alarma Ajuste predeterminado e La luz parpadea durante el per odo de precalentamiento eS disabled ODetection mode Only applicable to MS 12FE OFF Endesa Modo de detecci n Unicamente aplicable a MS 12FE Alarm signal is issued only when both upper and lower sensor detect objects simultaneously A ON Hia ie Contact output selectable Salida de contacto seleccionable La se al de alarma es emitida nicamente cuando los sensores superior e inferior detectan on o b N C objetos simult neamente ta Factory set Alarm signal is issued when either upper or 2 Ajuste predeterminado OR lower sensor detect objects Factory set La sefial de alarma es emitida cuando Pulse count selectable Contador de impulsos seleccionable Ajuste reiseriiedsl cualquiera de los sensores superior o p inferior detectan objetos The number of counts can be selected according to the environmental conditions El n mero de cuentas puede seleccionarse en conformidad con las i condiciones ambientales ODelay time Tiempo de retardo Operation time can be adjusted between 2sec and 5min approx El tiempo de funcionamiento puede ajustarse entre 2 seg y 5 min aprox Less sensi
3. TAKEX MS 12TE MS 12FE DUAL ZONE OUTDOOR PIR Instruction Manual PIR exterior de zona dual Manual de instrucciones 1 PARTS DESCRIPTION DESCRIPCI N DE LAS PIEZAS Wiring hole Operation LED Orificio del cableado LED operacional Adjustment lever Palanca de ajuste Sensitivity adjustment 7 Ajuste de sensibilidad Cover Tapa Body 7 Cuerpo Wire knockout 4 corners Orificio pretroquelado del cable 4 esquinas Upper Sensor Sensor f T Sensor superior Adjustment lever Palanca de ajuste Mode setting switches Sensitivity adjustment gt Interruptores de Ajuste de sensibilidad Ss 3 ajuste de modo Mode setting switches Interruptores de ajuste de modo Lower Sensor Sensor inferior Cover locking screw MS 12TE MS 12FE Tapa del tornillo de bloqueo Accessory Accesorio Area masking sheet MS 12FE 2 pcs MS 12TE 1 pc 2pcs L mina de enmascaramiento de rea Tornillo autorroscable MS 12FE 2 pzas MS 12TE 1 pza 2 pzas Y we Self tapping screw 2 PRECAUTIONS PRECAUCIONES Keep install height 2 6 to 4 0 Perpendicular installation 0 8 to 1 2m Instalaci n perpendicular Mantener la altura de instalaci n de 2 6 a 4 0 0 8 a 1 2 m E 2 6 4 0 0 8 1 2m Remove
4. all obstructions Remove all obstacles Retire todas las obstrucciones Retire todos los obstaculos Non detection area Area sin detecci n x Avoid exhaust vent Cross the detection zone Evite ventilaci n de escape Cruce la zona de detecci n Avoid strong light Avoid electrical noise Evite iluminacion intensa Evite ruido el ctrico 3 DETECTION AREA ZONA DE DETECCION Horizontal Zone Zona horizontal ALARM ALARMA Detection distance Distancia de detecci n Downward Zone Zona baja A Both zones detect Ambas zonas detectadas NO ALARM N SIN ALARMA Detection distance Distancia de detecci n B Horizontal zone doesn t detect No es posible detectar la zona horizontal 90 15 pitch 90 Giro 15 m ES X NO ALARM SIN ALARMA Detection distance Distancia de detecci n 90 15 pitch 90 Giro 15 C Downward zone doesn t detect No es posible detectar la zona baja Wide angle detection Detecci n de ngulo ancho PATTERNS OF COVERAGE MODELOS DE COBERTURA i Wall detection Detecci n de pared A When using wall detection ensure that the count setting is set to 1 NAl utilizar la detecci n de pared aseg rese de que el ajuste del contador est establecido en 1 gt JADJUSTMENT AJUSTE es a AREA ADJUSTMENT Horizontal adjustm
5. device TAKEX is not responsible for damage injury or losses caused by accident theft Acts of God including inductive surge by lightning abuse misuse abnormal usage faulty installation or improper maintenance PRODUCT DESCRIPTION The dual zone outdoor PIR is an automatic switch which uses passive infrared sensor to detect infrared body temperature emitted from a human body Suitable for indoor outdoor 1 This sensor is equipped with an AND detection and pulse count system 2 The AND detection system will issue an alarm signal only when detecion occurs in both horizon tal and downward zones simultaneously 3 The sensor is equipped with many features such as OOutput time delay switch setting OCombining the sensor with other devices such as a video monitoring system to display and record the presence of an intruder The sensor can be combined with an audible or visual warning device to annunciate the pres ence of visitors PAPRECAUTIONS Operation LED blinks for about 1min after turning on power During this warm up period the sensor does not detect This sensor operates during detecting time delay time set by a potentiometer It continues to issue an alarm as long as it detects objects regardless of the set delay time Do not pour water on this unit with a hose as it is designed to be rainproof not waterproof When detection mode is set at AND mode this sensor outputs an alarm signal only wh
6. o Detecta veh culos Horizontal zone AREA MASKING SHEET E L MINA DE ENMASCARAMIENTO DE REA Area Masking sheet L mina de enmascaramiento de rea Lens holder Soporte de la lente Cut the necessary i area number Detection range Downward zone Corte el numero de Rango de detecci n Zona baja t area necesario Ty Cut off Horizontal zone U Cortar N Zona horizontal T Cut the necessary Print side area number Lado de impresi n Corte el numero de Detection range Downward zone No detection area necesario Rango de detecci n Zona baja Sin detecci n Area number N mero de rea Zone cannot be masked by area masking sheet La zona O no puede enmascararse mediante la l mina de enmascaramiento de rea 6 ADJUSTMENT AJUSTE Warm up period Periodo de precalentamiento Operation LED blinks for about 1 min after supplying power b The unit doesn t operate for this time as it is the sensor stabilizing period Delay time fl Mode setting El LED de funcionamiento parpadea durante aproximadamente 1 minuto KO al encender la alimentaci n Smin La unidad no funcionar durante este per odo ya que es el per odo de Sensitivity adjustment estabilizaci n del sensor wy LED ON OFF selectable switch 9 OInterruptor LED ON OFF seleccionable Ms 12FE only
7. quina el ctrica o su cableado est cerca del cableado del sensor Cambie la colocaci n del dispositivo Reflexi n intensa de iluminaci n solar o foco reflejado en el sensor Cambie la colocaci n del dispositivo Reajuste los ajustes del rea de protecci n Las luces reflectantes como la luz solar o los focos afectan a la zona baja Retire los objetos reflectantes Reajuste los ajustes del rea de protecci n Instalaci n del sensor incorrecta Instale el sensor paralelamente La distancia de detecci n de la zona baja es demasiado larga Reajuste la distancia de detecci n Los coches o motos ubicados delante del rea de detecci n podr an activar el sensor Para evitar tales detecciones no deseadas reajuste la configuraci n del rea y el ajuste del rango El LED de alarma se ilumina aunque el dispositivo conectado est inactivo Conexi n de contacto baja o cable da ado o cortocircuito Compruebe el cableado o conexi n La salida de contacto no funciona Compruebe el terminal de salida de contacto utilizando un potenci metro Es el funcionamiento del dispositivo Compruebe el dispositivo conectado conectado normal TAKENAKA ENGINEERING CO LTD In Japan In the U S In Australia In the U K Takenaka Engineering Co Ltd 83 1 Gojo sotokan Higashino Yamashina ku Kyoto 607 8156 Japan Tel 81 75 501 6651 Fax 81
8. utiliza nicamente a modo de gu a eAjuste de rea Tenga en cuenta la direcci n probable de desplaza miento del objeto para maximizar la posibilidad de cruce de las zonas sensitivas e Ajuste de la sensibilidad mediante el potenci metro del SENSOR PIR Tenga en cuenta que el rango de detecci n actual podr a reducirse en hasta un 20 si la temperatura ambiental es tan alta que hay muy poca diferencia entre la temperatura del objeto a detectar y el fondo Consulte la siguiente imagen En dicho caso se recomienda aumentar el rango de detecci n para compensar eSi hay un camino o carretera delante de la zona de detecci n los veh culos con una temperatura comparablemente superior a la del cuerpo humano ser n detectados a mayor distancia Para evitar tales detecciones no deseadas reajuste la configuraci n del rea y el ajuste del rango EJL MINA DE ENMASCARAMIENTO DE REA 1 Corte el n mero de rea necesario en la l mina de enmascaramiento de rea Consulte la imagen del enmascaramiento del rea a modo de referencia y corte los mismos lugares en las zonas horizontal y baja 2 Coloque la l mina de enmascaramiento de rea en el soporte de la lente ubicado en el interior de la tapa 3 Coloque la tapa y compruebe la zona de detecci n La zona O no puede enmascararse mediante la l mina de enmascaramiento de rea EJINSTALACI N 1 Antes de realizar la instalaci n lea PRECAUCIONES amp 2
9. 75 593 3816 Takex America Inc 3350 Montgomery Drive Santa Clara CA 95054 U S A Tel 408 747 0100 Fax 408 734 1100 Takex America Inc 4 15 Howleys Road Notting Hill VIC 3168 Tel 61 03 9544 2477 Fax 61 03 9543 2342 http www takex eng co jp http www takex com Takex Europe Ltd Takex House Aviary Court Wade Road Basingstoke Hampshire RG24 8PE U K Tel 44 01256 475555 Fax 44 01256 466268 http www takexeurope com No 05 687 1406
10. Afloje el tornillo de bloqueo de la tapa y extraiga la tapa Consulte CABLEADO y conecte los cables al terminal Instale la unidad Consulte ZONA DE DETECCI N y COMPROBACI N DEFUNCIONAMIENTOycom pruebe el rea de detecci n y el funcionamiento 6 Vuelva a colocar la tapa COMPROBACI N DE FUNCIONAMIENTO 1 Ajuste para funcionamiento LED operacional ON Tiempo de retardo 2 seg ODetermine el rea de detecci n necesaria y ajuste el ngulo horizontal del sensor y la distancia de detecci n Coloque la tapa y fijela al sensor con el tornillo de bloqueo OActive la alimentaci n y espere 1 min hasta que el LED de alarma deje de parpadear OfTras el per odo de precalentamiento realice una prueba de desplazamiento en el rea de detecci n a comprobar si el rea requerida est cubierta OReajuste la sensibilidad enmascaramiento o contador si fuese necesario wo as la comprobaci n del 2 Comprobaci n de funcionamiento ORealice los ajustes finales en conformidad con el prop sito OColoque la tapa y compruebe si el LED operacional y los dispositivos conectados funcionan correctamente Aseg rese de que no se produzca detecci n no deseada del tr fico incluyendo veh culos si hay un camino o carretera delante de la zona de detecci n Garant a limitada Los productos TAKEX poseen una garant a de 12 meses a partir de la fecha original de compra contra defectos en el materia
11. alado amp terior eBreak inside knockout pull wire through wiring hole and connect it to the terminals eRompa el interior del orificio pretroquelado pase el cable a trav s del orificio de cableado y con ctelo a los terminales Wiring hole 4 Orificio del cableado Wiring box Caja del cableado When installing the sensor to flush mount box use wall mount bracket BW 24 sold separately Al instalar el sensor en una caja de montaje al ras utilice un soporte de pared BW 24 vendido por separado Outside knockout Orificio pretroquelado exterior DIMENSIONES EXTERNAS KNOCKOUT ORIFICIO PRETROQUELADO 0 45 x0 31 11 5mmx8mm r OPERATION LED LED OPERACIONAL 2 90 18 3 58 8 25 209 5mm ue MOUNT HOLE emm ORIFICIO DE MONTAJE COVER LOCKING SCREW TORNILLO DE BLOQUEO DE LA TAPA KNOCKOUT ORIFICIO PRETROQUELADO 0 45 x0 31 11 5mmx8mm Instruction Manual MS 12TE amp MS 12FE We appreciate your purchase of a TAKEX passive infrared sensor This sensor will provide long and dependable service when properly installed Please read this Instruction Manual carefully for correct and effective use Please Note This sensor is designed to detect intrusion and to initiate an alarm it is not a burglary preventing
12. ation check Make final setting according to the purpose OAttach cover and check if operation LED and connected devices operate properly Make sure that there is no undesirable detection of traffic including vehicles if there is a path or road at the front of detection zone SPECIFICATIONS Model MS 12TE MS 12FE Detection system Passive infrared Coverage When horizontal detection Angle 90 Detection distance 40 12m Horizontal zone 7zones Downward zone 7zones Angle 90 x2 2sets of MS 12TE sensors Coverage adjustment Horizontal 90 Detection distance 6 6 40 2m 12m By adjusting vertical angle of downward curtain Power supply 12 to 30V DC non polarity Current consumption 35mA MAX 40mA MAX Alarm output Dry contact relay output N C N O selectable Contac Contac capacity 30V AC DC 0 5A MAX Resistive load operation Detection time off delay 2sec 5min approx Tamper output Dry contact relay output N C Contac capacity 30V AC DC 0 5A MAX Resistive load Operation LED Red LED Blinking at warming up LED disabled Lighting at alarm LED disabled Pulse count 1 3 with a switch Pole attachment BP 22 Sensitivity adjustment Approx 30 L Approx 170 H By Potentiometer Detection mode AND OR selectable Connection Terminals Ambi
13. e bloqueo de la tapa 2 Wiring distance 2 Distancia de cableado Power voltage Voltaje de alimentaci n DC12V DC24V 820 250m 8500 2600m 1480 450m 14100 4300m 2300 700m 21300 6500m 3120 950m 29500 9000m Size of wire used Tamano del cable utilizado 0 3mm 0 65mm 0 5mm 0 8mm 0 8mm 1 0mm 1 2mm 41 25mm NOTE 1 Maximum wiring distance when two or more sets are connected is the value above divided by number of sets 2 The signal line can be wired to a distance of up to 3 000ft 1 000m with AWG 22 dia 0 65mm telephone wire NOTA 1 La distancia de cableado maxima al conectar dos o m s juegos es el valor de arriba dividido entre el numero de juegos 2 La l nea de se al puede cablearse a un distancia de hasta un m ximo de 3 000 pies 1 000 m con cable de tel fono AWG 22 di 0 65 mm 3 Wiring insertion 3 Inserci n del cableado Exposed wiring Cableado expuesto Break one outside knockout and its related inside knockout as necessary Pull wire through the insertion holes and connect it to the terminals eRompa uno de los orificios pretroquelados exteriores y su pretroquelado interior seg n sea necesario nds knockout Pase el cable a trav s de los orificios Orificio pretroquelado de inserci n y con ctelo a los interior terminales Outside knockout Orificio pretroquelado Mounted wiring Cableado inst
14. eWhen there is a path or road at the front of detection zone vehicles with comparatively higher tempera ture than human body may be detected at a longer distance Readjust the area setting and range adjust ment when there is such undesirable detections EJAREA MASKING SHEET 1 Cut the necessary area number on the area mask ing sheet See the area masking picture for your reference and cut out the same place on both horizontal and downward zones 2 Attach the area masking sheet to the lens holder located inside cover 3 Attach cover and check detection zone Zone O cannot be masked by area masking sheet EJINSTALLATION 1 Read PB PRECAUTIONS before installation 2 Loosen cover locking screw and detach cover 3 Refer to WIRING and connect wires to the terminal 4 Install the unit 5 Refer to E DETECTION AREA and OPERATION CHECK and check detection area and operation 6 Replace the cover OPERATION CHECK 1 Setting for operation check Operation LED ON Delay time 2 sec ODetermine the required area of detection and set the horizontal angle of the sensor and detec tion distance OAttach cover and fix it to the sensor with the locking screw OTurn the power ON and wait for 1min until the alarm LED stops blinking OAfter warm up period operate a walk test in the detection area to check if the required area is covered OReadjust sensitivity necessary masking or count if 2 Oper
15. eee L7 POWER SUPPLY SUMINISTRO DE ALIMENTACI N e 12V to 30VDC non polarity e Current consumption 35mA MAX MS 12TE 40mA MAX MS 12FE e 12 V a 30 V CC sin polaridad e Consumo actual 35 mA m x MS 12TE 40 mA m x MS 12FE ALARM OUTPUT SALIDA DE ALARMA e Dry contact relay output form N C N O selectable CONTACT CAPACITY 30V AC DC 0 5A MAX resistive load CONTACT OPERATION Detection time off delay 2sec 5min approx e Forma de salida de rel de contacto seco N C N O seleccionable CAPACIDAD DE CONTACTO 30 V CA CO 0 5 A m x carga resistiva OPERACI N DE CONTACTO Tiempo de detecci n retardo desconexi n 2 seg 5 min aprox TAMPER e Dry contact relay output N C CONTACT CAPACITY 30V AC DC 0 5A MAX resistive load e Salida del rel de contacto seco N C CAPACIDAD DE CONTACTO 30 V CA CC 0 5 A max carga resistiva OWIRE SIZE AWG24 AWG14 0 2mm 2mm TAMA O DEL CABLE AWG24 AWG14 0 2 mm 2 mm Standard connection Conexi n est ndar When two units are used al utilizar dos unidades Power Noe Alimentaci n O Alarm input O Entrada de alarma O Tamper input O Entrada anti sabotaje Controller Controlador 00 040006 N C Cover Locking screw Tornillo d
16. en both upper and lower sensor detect objects In other words it won t make detection in the area which is not covered by both upper and lower sensor Only applicable to MS 12FE Upper sensor coverage No detection Ci ps NN 4 Ar SO bi KA Detection area The area covered by both upper and lower sensor Lower sensor coverage No detection Upper sensor coverage Lower sensor coro DETECTION AREA The detection zone of this unit consists of a horizontal zone and downward zone Alarm signal is issued only when both detection zones detect objects Detection distance can be set by adjusting the angle of downward zone MS 12TE is equipped with 1set of sensors on the upper side MS 12FE is equipped with 2sets of sensors on the upper and lower side making it possible to select AND mode or OR mode A Alarm signal is issued only when both horizontal and downward zone detect objects B It does not detect small animals which are not likely to reach the height of horizontal zone C It does not detect vehicles moving in the area outside the range of the downward zone PATTERN OF COVERAGE Wide angle detection 1 Point the sensor to the center of the area to be detected By turning the sensor up to 45 it can detect all zones in front of it When the unit is turned more than 45 detection zone will be eliminated one by one from the end 2 It consists of seven d
17. ent AJUSTE DE AREA Ajuste horizontal Fine adjustment Wall detection Ajuste de precisi n Detecci n de pared a Al Away from the wall Alejado de la pared Sensor e Towards the wall Hacia la pared MS 12TE 90 180 AJUSTABLE VARIABLE TOP VIEW VISTA SUPERIOR Horizontal Detection Detecci n horizontal ADJUSTABLE 90 VARIABLE 180 Fine Adjustment Ajuste de precisi n TOP VIEW VISTA SUPERIOR Wall Detection Detecci n de pared Masking unnecessary zones Enmascarando zonas innecesarias Horizontal Zone Zona horizontal 33 paa PRIETO SIDE VIEW in eel VISTA LATERAL 0 gt 16 5 NATA 5m Downward Zone Zona baja Variable range Rango variable Detection distance is set by adjusting the angle of downward zone Adjustable range 6 6 2m to 40 12m 10 ranges Distancia de detecci n ajustada por el ajuste del ngulo de la zona baja Rango ajustable de 6 6 2 m a 40 12 m 10 rangos MS 12FE Fine Adjustment Ajuste de precisi n 3930 12m 1117 40 10m 33 A 22222222777 TOP VIEW VISTA SUPERIOR Horizontal Detection Detecci n horizontal x2 UPPER SENSOR SENSOR SUPERIOR LOWER SENSOR 16 5 SENSOR INFERIOR 5m ou al LOWER SENSOR COVERAGE VARIABLE 180 COBERTURA DEL SENSOR SUPERIOR COBERTURA DEL SENSOR INFERIOR
18. ent temperature 4 F to 122 20 C to 50 C Mounting position Indoor Outdoor Ingress protection IP 54 Weight 13 70z 390g 16 50z 470g Appearance Body AES resin Lens PE resin Optional Wall mount attachment BW 24 TROUBLESHOOTING Solve possible problems according to the following table If normal operations cannot be restored by this means contact either the dealer from whom you bought the unit or TAKEX Trouble Check Corrective Action Completely inactive No power supply broken wire or improper voltage Correct power supply or replace broken wire Cover shielded by substances including glass Remove the substances Improper area adjustment Readjust the protection area setting Not yet 1minute after power turned on Operation LED is flickering Allow for warming up time about 1min No area covered by both upper and lower sensor when set at AND mode Only applicable to MS 12FE Readjust the sensor angle so that the area to be detected is covered by both upper and lower sensor Sometimes inactive Improper area adjustment Readjust the protection area setting Cover face is soiled with dust or water drop Clean the cover with soft cloth Area covered by both upper and lower sensor is too small to be detected when set at AND mode Only applicable to MS 12FE Readjust the sensor angle Activated when no person has passed Unstab
19. etection range may decrease when the object being detected of similar temperature to the ambient target area eDirection of object path PIR detection works best when movement crosses the sensitive zones Sensitivity deteriorates when movement is directly towards the detector within single zones Mounting height The closer the mounting height is to the ground the shorter the achievable detection range Mounting orientation Detector should be installed on a true vertical to ensure proper detection range eSlope in detection area When the ground slopes downward upward from the sensor the detection range becomes longer shorter The following settings should be appropriately ad justed by WALK TEST in order to obtain expected performance of the detector according to the various environmental factors of the installation site eDetection range adjustment Adjustment lever with 10 steps The distance index is not definitive and is only to be used as a guide eArea setting Consider likely object travel direction to maximise possibility of crossing sensitive zones eSensitivity setting by PIR SENS pot Note that the actual detection range may lessen by up to 20 when the ambient temperature is enough high so that there is a little temperature difference the object to be detected and the background See below figure If this situation is likely then it is recommended to increase the detection range to compensate
20. etection zones Wide angle 90 3 Ustilize attached area masking sheet when elimi nating detection zones Wall detection 1 Attach area masking sheet to the lens holder inside the cover without cutting it out Refer to Area masking on how to attach the sheet to the lens holder 2 Rotate the sensor by 90 and face it to the direction to be detected 3 Horizontal fine adjustment Fine adjustment can be made within the range of 3 in case there is some obstacles on the wall Detection zone shifts about 2 0 6m at 40 12m range Slide the lever to the left or right AREA ADJUSTMENT Horizontal adjustment e Make sure that the lever be set at 0 for horizontal detection When shifting detection zone away from the wall slide the lever towards the wall When shifting detection zone towards the wall slide the lever away from the wall ZADETECTION DISTANCE ADJUSTMENT Detection distance can be adjusted within a range from 6 6 2m to 40 12m by turning the angle of downward zone vertically Refer to the index and slide the adjustment lever up or down Slide it up and the detection distance becomes shorter sliding it down detection distance becomes longer IMPORTANT NOTES The following factors may have an effect on the actual detection range or sensitivity The greater the distance covered the more prominent this effect becomes eAmbient temperature vs object temperature Actual d
21. idad m s de 45 las zonas de detecci n ser n eliminadas una a una desde el extremo 2 Consiste de siete zonas de detecci n Ancho de ngulo 90 3 Utilice la l mina de enmascaramiento de rea adjunta al eliminar zonas de detecci n Detecci n de pared 1 Coloque la l mina de enmascaramiento de rea en el soporte de la lente en el interior de la tapa sin cortarla Consulte el enmascaramiento de zona para averiguar c mo adherir la l mina al soporte de la lente 2 Gire el sensor 90 y col quelo delante de la direc ci n a detectar 3 Ajuste de precisi n horizontal El ajuste de precisi n puede hacerse dentro de un rango de 3 por si acaso existen obst culos en la pared La zona de detecci n cambia aproximada mente 2 0 6 m en un rango de 40 12 m Deslice la palanca hacia la izquierda o derecha AJUSTE DE REA Ajuste horizontal e Aseg rese de que la palanca est ajustada a 0 para la detecci n horizontal Para alejar la zona de detecci n de la pared deslice la palanca hacia la pared Para acercar la zona de detecci n a la pared deslice la palanca en direcci n contraria a la pared EJ AJUSTE DE LA DISTANCIA DE DETECCI N La distancia de detecci n puede ajustarse en un rango de 6 6 2 m a 40 12 m girando el ngulo de la zona baja verticalmente Consulte el ndice y deslice la palanca de ajuste hacia arriba o hacia abajo Si la desliza hacia arriba la dis
22. imentaci n cable roto o voltaje inadecuado Corrija el suministro de alimentaci n o sustituya el cable da ado La tapa est cubierta por substancias incluyendo cristal Elimine las substancias Ajuste de rea incorrecto Reajuste los ajustes del rea de protecci n No ha transcurrido 1 minuto desde que activ la alimentaci n LED operacional parpadeando Deje que transcurra el per odo de precalentamiento aproximadamente 1 min No hay ning n rea cubierta por los sensores superior e inferior al ajustar al modo AND Unicamente aplicable a MS 12FE Reajuste el ngulo del sensor de manera que el rea a detectar est cubierta por ambos sensores superior e inferior Algunas veces inactivo Ajuste de rea incorrecto Reajuste los ajustes del rea de protecci n La superficie de la tapa est cubierta por polvo o gotas de agua Limpie la tapa con un pa o suave rea cubierta por el sensor superior e inferior demasiado peque a como para ser detectada en el modo AND Unicamente aplicable a MS 12FE Reajuste el ngulo del sensor Se activa sin que pase ninguna persona Voltaje de alimentaci n inestable Estabilice el voltaje de alimentaci n Algo se est moviendo por el rea protegida o existen variaciones de temperatura demasiado r pidas Elimine la causa Hay cerca una fuente de ruido el ctrico grande como por ejemplo una m
23. ing inductive surge by lightning abuse misuse abnormal usage faulty installation improper maintenance or any repairs other than those provided by TAKEX All implied warranties with respect to TAKEX including implied warranties for merchantability and implied warranties for fitness are limited in duration to 12 months from original date of shipment During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipment and nature of difficulty being experienced There will be charges rendered for product repairs made after our Warranty period has expired Manual deinstrucciones MS 12TE amp MS 12FE Le agradecemos que haya adquirido un sensor de infrarrojos pasivo TAKEX Instalar correctamente este sensor proporcionar una larga vida til de alta fiabilidad Por favor lea detenidamente este manual de instrucciones para un uso correcto y efectivo Atenci n Este sensor est dise ado para detectar intrusiones e iniciar una alarma no es un dispositivo de prevenci n de robo TAKEX no se hace responsable por da os lesiones o p rdidas ocasionados por accidentes robos desastres naturales incluyendo las cargas inductivas causadas por rel mpagos abuso mal uso uso anormal instalaci n defectuosa o mantenimiento inadecuado DESCRIPCI N DEL PRODUCTO El PIR exterior de zona dual es un in
24. l y la mano de obra Nuestra garant a no cubre los da os o fallos ocasionados por desastres naturales incluyendo las descargas induc tivas por rel mpagos abuso mal uso uso anormal instalaci n defectuosa mantenimiento inadecuado o por cualquier reparaci n que sea diferente a aquellas proporcionadas por TAKEX Todas las garant as impl citas con respecto a TAKEX incluyendo las garant as impl citas por mercadotecnia e idoneidad se encuentran limitadas a una duraci n de 12 meses a partir de la fecha original de la compra Durante el periodo de garant a TAKEX reparar o reemplazar a su sola discreci n y sin cargo alguno cualquier pieza defectuosa franqueada Indique el n mero de modelo de los productos la fecha original de compra y la naturaleza de las dificultades experimentadas Existir n cargos por las reparaciones del producto re alizadas una vez transcurrido el periodo de garant a ESPECIFICACIONES Modelo MS 12TE MS 12FE Sistema de detecci n Infrarrojo pasivo Cobertura Durante la detecci n horizontal Angulo 90 Distancia de detecci n 40 12 m Zona horizontal 7 zonas Zona baja 7 zonas ngulo 90 x2 2 juegos de sensores MS 12TE Ajuste de cobertura Horizontal 90 Distancia de detecci n 6 6 40 2 m 12 m Ajustando el ngulo vertical a la cortina baja Suministro de alimentaci n 12 a 30 V CC sin polaridad Consumo de corriente 35 mA
25. larma cuando tanto el sensor inferior como el superior detectan objetos En otras palabras no realizar la detecci n en el rea no cubierta por el sensor superior e inferior nicamente aplicable a MS 12FE Cobertura del sensor superior sin detecci n Y gora de detecci n Ve rea cubierta por el S superior e inferior Cobertura del sensor inferior sin detecci n Cobertura del sensor wile ElZONA DE DETECCI N La zona de detecci n de esta unidad consiste de una zona horizontal y una zona baja La se al de alarma es emitida nicamente cuando ambas zonas de detecci n detectan objetos La distancia de detecci n puede ser configurada mediante el ajuste del ngulo de la zona baja MS 12TE est equipado con 1 juego de sensores en el lado superior MS 12FE est equipado con 2 juegos de sensores en el lado superior y en el inferior posibilitando selec cionar el modo AND o el modo OR A La se al de alarma es emitida nicamente cuando ambas zonas de detecci n horizontal y baja detectan objetos B No detecta peque os animales que probablemen te no alcanzar n la altura de la zona horizontal C No detecta veh culos movi ndose en el rango del rea exterior de la zona baja MODELO DE COBERTURA Detecci n de ngulo ancho 1 Apunte el sensor al centro del rea a detectar Girando el sensor hasta un m ximo de 45 podr detectar todas las zonas delante del mismo Al girar la un
26. le power voltage Stabilize the power voltage Something moving in protected area or too rapid temperature variations Remove the cause Large electrical noise source such as power machine nearby or its wiring close to that of sensor Relocate device Intense reflection of sun light or head light shining on the sensor Relocate device Readjust the protection area setting Reflective lights such as sun light or head light affect the downward zone Remove reflective objects Readjust the protection area setting Improper installment of the sensor nstall the sensor parallel Detection distance of the downward zone is too long Readjust detection distance Cars or motor bikes located at the front of detection area may activate the sensor Readjust the area setting and range adjustment so that there is no such undesirable detections The alarm LED lights but connected device is inactive Poor contact connection or broken wire or short circuit Check the wiring or connection Contact output is not working Check the contact output terminal using a tester Is the connected device operation normal Check the connected device Limited Warranty TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment Our warranty does not cover damage or failure caused by Acts of God includ
27. m x 40 mA m x Salida de alarma Salida del rel de contacto seco N C N O selec cionable Capacidad de contacto 30 V CA CC 0 5 A max Carga resistiva Funcionamiento del contacto Tiempo de detec aprox ci n retardo desconexi n 2 seg 5 min Salida de tamper Salida del rel de contacto seco N C Capacidad de contacto 30 V CA CC 0 5 A max Carga resistiva LED operacional LED rojo Parpadea durante el precalentamiento LED desactivado lluminado al producirse una alarma LED desaci ivado Interruptor contador 1 3 con un interruptor Ajuste de sensibilidad Aprox 30 m n Aprox 170 m x median te potenci metro Modo de detecci n AND OR seleccionable Conexi n Terminales Temperatura ambiente 4 F a 122 20 C a 50 C Posici n de montaje Interior Exterior Protecci n de ingreso IP 54 Peso 13 7 oz 390 g 16 5 oz 470 g Apariencia Cuerpo Resina AES Lente Resina PE Opcional Accesorio de instalaci n en pared BW 24 Accesorio de barra BP 22 RESOLUCI N DE PROBLEMAS Resuelva posibles problemas consultando la siguiente tabla Si tras lo cual no puede restablecer el funcionamiento normal p ngase en contacto con el proveedor de adquisici n de la unidad o con TAKEX Problema Comprobaci n Soluci n Completamente inactivo Sin suministro de al
28. tancia de detecci n se acorta si la desliza hacia abajo la distancia de detecci n aumenta AVISOS IMPORTANTES Los siguientes factores podr an afectar el rango de detecci n o la sensibilidad actuales Cuanto mayor sea la distancia cubierta m s obvio ser este efecto eTemperatura ambiental versus temperatura del objeto El rango de detecci n actual podr a disminuir si el objeto a detectar posee una temperatura similar a la de la zona objetivo eDirecci n de la ruta del objeto La detecci n PIR funciona mejor cuando el movi miento cruza las zonas sensitivas La sensibilidad se deteriora si el movimiento se produce directamente hacia el detector dentro de zonas individuales eAltura de montaje Cuanto m s cerca se encuentre la altura de mon taje del suelo menor ser el rango de detecci n obtenible e Orientaci n de montaje El detector debe instalarse verticalmente para asegurar un rango de detecci n adecuado ePendiente en la zona de detecci n Si el suelo se inclina hacia abajo hacia arriba del sensor el rango de detecci n aumenta disminuye Los siguientes ajustes deber n ser debida mente configurados mediante la PRUEBA DE DESPLAZAMIENTO con la finalidad de obtener el rendimiento esperado del detector en conformidad con los distintos factores ambientales del lugar de instalaci n e Ajuste del rango de detecci n Palanca de ajuste con 10 pasos El ndice de la distancia no es definitivo y se
29. terruptor auto m tico que utiliza un sensor de infrarrojos pasivo para detectar infrarrojos temperatura del cuerpo emitidos por un cuerpo humano Adecuado para interiores exteriores 1 Este sensor est equipado con una detecci n AND y con un sistema contador de impulsos 2 El sistema de detecci n AND emitir una se al de alarma nicamente al producirse la detecci n en las zonas horizontal y baja simult neamente 3 El sensor est equipado con muchas funciones como por ejemplo OAjuste del interruptor de retardo del tiempo de emisi n OCombinando el sensor con otros dispositivos como por ejemplo un sistema de monitorizaci n de v deo para visualizar y grabar la presencia de un intruso El sensor puede ser combinado con un dispositi vo de advertencia visual o audible para anunciar la presencia de visitantes PAPRECAUCIONES El LED operacional parpadea durante aproximada mente 1 minuto al encender la alimentaci n Durante este per odo de precalentamiento el sensor no detecta Este sensor funciona durante el tiempo de detecci n tiempo de retardo ajustado por un potenci metro Continuar emitiendo la alarma mientras detecte objetos sin importar el tiempo de retardo ajustado No derrame agua sobre esta unidad con una man guera ya que est dise ada para soportar la lluvia no est hecha a prueba de agua Cuando el modo de detecci n est ajustado al modo AND este sensor emite una se al de a
30. tive prevents false alarms caused Oo by temperature fluctuation Menos sensitivo evita las falsas alarmas Operation time can be adjusted between 2sec and causadas por la fluctuaci n de la temperatura 5min approx Factory set 2sec El tiempo de funcionamiento puede ajustarse entre 2 seg y 5 min aprox Ajuste predeterminado 2 seg Set for sensitive detection of even small movements by people however this may be more susceptible to false alarms 1 For wall detection use this setting Factory set Ajustado para una detecci n sensitiva de incluso el m s Aj i m nimo movimiento humano sin embargo podr a ser m s gir ok M z spans Ajuste predeterminado soeple a falsas lamas OSensitivity adjustment Ajuste de sensibilidad Para la detecci n de pared use este ajuste Aa 7 Sensitivity can be adjusted between 30 L and MS 12FE has two sets of above switches upper and lower sensor O 170 H Factory set 100 MS 12FE tiene dos juegos de los anteriores interruptores para el La sensibilidad puede ajustarse entre 30 m n y sensor superior e inferior L H 170 m x Ajuste predeterminado 100 7 WIRING CABLEADO 1 Terminal Configuration 1 Configuraci n del terminal Power Alimentaci n Alarm output Salida alarma Tamper NL 2218 S

Download Pdf Manuals

image

Related Search

Related Contents

Journey User Manual  Manuel d`installation  Cooper Lighting TMU/TLU User's Manual  Samsung GT-S5628 用户手册  ECW-281B/B2 Series - Comp-Mall  Page 1 Page 2 PREMI EF. CHAPlTRE Parlons la même langue  Ergotron 100 Series Extender, 5-inch. Black  Operating Instructions (German)    Manual_Tecnico_Portugues  