Home
0137828 Antenna Isolation Kit Instructions Model
Contents
1. Antenna Isolation Kit K001A3200 2 The antenna isolation kit protects gate operator components from possible damage caused by certain wiring configurations The To reduce the risk of SERIOUS INJURY or DEATH installation of some accessories require one of the outputs from Disconnect electric power at the fuse box BEFORE the transformer be shunted to the chassis ground which may blow proceeding the transformer fuse or damage the pre installed universal e ALL electrical connections MUST be made by a qualified receiver LiftMaster does NOT recommend connecting the individual transformer outputs to the chassis ground however some third e Upon completion of kit installation the area MUST be party accessories require one of the transformer outputs to be cleared and secured At that time the unit may be returned shunted to the chassis ground to service The isolation kit is for use with gate operators models SL575 SL585 SL595 HS670 SW420 SW279 and SW490 CARTON INVENTORY Nylon Flat Washer 216A0253 Nylon Shoulder Washer 184A0182 USE ee ea at 35 310 032 FUSE cd een 35 310 032 1 TOOLS NEEDED e Pliers and wrenches e Screwdrivers Diagonal wire cutters Wire strippers e Drill 1 2 drill bit Digital voltmeter DETERMINE IF THE ISOLATION KIT IS NEEDED MEASUREMENT POINTS VOLTAGE INSTRUCTIONS To determine if the isolation kit is needed for yo
2. a nee 35 310 032 1 OUTILS NECESSAIRES e Pinces et cl s e Tournevis e Coupe fils diagonaux e Pinces d nuder e Perceuse e M che de 1 2 po e Voltm tre num rique DETERMINER SI LE N CESSAIRE D ISOLATION EST NECESSAIRE Pour d terminer si le n cessaire d isolation est n cessaire pour votre installation 1 D connecter l alimentation l actionneur 2 D connecter le r cepteur universel mod le 850LM de l actionneur L emplacement varie en fonction de l actionneur consulter cet effet le manuel du propri taire 3 Connecter tous les autres accessoires conform ment aux instructions qui les accompagnent Restaurer l alimentation l actionneur Configurer un voltm tre num rique pour mesurer la tension c a Prendre trois lectures de la tension entre les points suivants R1 R2 R1 masse du ch ssis et R2 masse du ch ssis L emplacement varie en fonction de l actionneur consulter cet effet le manuel du propri taire S il n y a aucune tension entre R1 R2 v rifier si le fusible du transformateur est grill Si le fusible est grill le remplacer par le fusible appropri inclus dans le n cessaire et mesurer de nouveau la tension 6 Consulter le tableau et suivre les instructions indiqu es par votre ensemble de mesures de tension a AA AVERTISSEMENT Pour r duire le risque de BLESSURES GRAVES voire MORTELLES e D connecter l alimentation au niveau de la bo t
3. ance gt Connect the negative or black lead of the voltmeter to the F connector used to ground the universal receiver antenna OPOLOPO 5 Connect the positive or red lead of the voltmeter to a The power input of the universal receiver If the meter ll reads 00 there is a short indicating the universal receiver Seien is damaged Replace the universal receiver iit b The power input of the universal receiver If the meter reads 00 there is a short indicating the universal receiver is damaged Replace the universal receiver NOTE Don t confuse 00 with Q 6 Ifthe voltmeter does not indicate a short the universal receiver can be used INSTALL THE ISOLATION KIT To install the isolation kit 1 Disconnect power to the operator 2 Remove all accessories from the operator 3 Locate the chassis mounted F connector where the coax Chassis antenna passes through the operator chassis Location F connector varies depending on the operator refer to the owner s To antenna Nylon flat washer manual 4 Disconnect the coax cables from both sides of the F O WOT connector washier 5 Remove the F connector and the mounting hardware Set aside for reinstallation 6 Drill out the hole using a 1 2 drill bit 7 Reinstall the F connector to the chassis Insert the isolation washers between the operator chassis and the other hardware The shoulder washer should go on t
4. ar la instalaci n del juego limpiar y despejar el chasis pero ciertos accesorios de terceros exigen que una de las lugar Entonces la unidad podr ponerse en servicio salidas del transformador est puenteada a tierra del chasis El juego de aislamiento es apto para los siguientes modelos de operadores de port n SL575 SL585 SL595 HS670 SW420 SW279 y SW490 CONTENIDO DE LA CAJA Arandela plana de nailon 21640253 Arandela de nailon con resalto 18440182 Fusible 4 ur ra a 35 310 032 FUSIDIE v sre fama us du pente au tes 35 310 032 1 HERRAMIENTAS NEGESARIAS Pinza y llaves e Destornilladores e Alicates e Pelacables e Taladro e Broca de 1 2 de pulg e Voltimetro digital DETERMINAR SI ES NECESARIO USAR EL PUNTOS DE MEDICION VOLTAJE INSTRUCCIONES JUEGO DE AISLAMIENTO Ninguna de las salidas Para determinar si es necesario usar el juego de aislamiento del transformador esta 1 Desconectar la alimentaci n el ctrica del operador R1 tierra de chasis puenteada a tierra 2 Desconectar del operador el receptor universal modelo El juego de aislamiento 850LM El lugar de instalaci n depender del tipo de R2 tierra de chasis NO es necesario operador Consultar el manual de instrucciones 3 Conectar los dem s accesorios seg n sus propias instrucciones R1 R2 R1 est puenteado a 4 Conectar la alimentaci n el ctrica del operador tierra 5 Po
5. e fusibles AVANT de poursuivre TOUTES les connexions lectriques DOIVENT tre effectu es par une personne qualifi e Apr s l installation du n cessaire d isolation la zone DOIT tre d gag e et s curis e Ce n est qu ce moment que l unit peut tre remise en service POINTS DE MESURE R1 R2 TENSION 24 V Ca INSTRUCTIONS Aucune des sorties du transformateur n est mise la masse Le n cessaire d isolation n est PAS n cessaire Environ 14 V ca Environ 14 V c a R1 masse du ch ssis R2 masse du ch ssis R1 est court circuit la masse Passer MISE L ESSAI DU RECEPTEUR UNIVERSEL POUR DETECTION DE DOMMAGE R1 R2 R1 masse du chassis R2 masse du chassis R2 est court circuit a la masse Passer MISE L ESSAI DU RECEPTEUR UNIVERSEL POUR DETECTION DE DOMMAGE LiftMaster R1 R2 R1 masse du chassis R2 chassis ground MISE A L ESSAI DU RECEPTEUR UNIVERSEL POUR DETECTION DE DOMMAGE Il est possible que vous deviez remplacer le r cepteur universel pr install mod le 850LM Pour tester le r cepteur universel afin de d tecter tout dommage 1 D connecter l alimentation a l actionneur 2 D connecter le r cepteur universel de l actionneur 3 Configurer un voltm tre num rique pour mesurer la r sistance 4 Connecter la borne n gative ou noire du voltm tre au connecteur F utilis pour me
6. he inside of the operator The flat washer should go on the outside of the operator See illustration for assembly order 8 Reconnect the coax cables to the F connector 9 Connect the antenna ground to the chassis 10 Connect all other accessories according to the instructions that came with them 11 Restore power and test the operator N cessaire d isolation d antenne K001A3200 2 APPLICATION Le n cessaire d isolation d antenne prot ge les composants de l actionneur de barri re contre les dommages possibles caus s par certaines configurations de c blage L installation de certains accessoires exige que l une des sorties du transformateur soit court circuit e la masse du ch ssis laquelle peut faire griller le fusible du transformateur ou endommager le r cepteur universel pr install LiftMaster DECONSEILLE de connecter les sorties du transformateur la masse du ch ssis toutefois certains accessoires tiers exigent que l une des sorties du transformateur soit court circuit e la masse du ch ssis Le n cessaire d isolation a t pr vu pour tre utilis avec les mod les d actionneur de barri re suivants SL575 SL585 SL595 HS670 SW420 SW279 et SW490 INVENTAIRE DE L EMBALLAGE Rondelle plate en nylon 216A0253 Rondelle paulement en nylon 184A0182 FUSIDIE u 24 002 200 due uen ste 35 310 032 FUSIDIE 4 444 2 052 20 0 nase n
7. ner el selector del voltimetro digital para medir voltaje de R1 tierra de chasis Vez secci n PROBAR EL corriente alterna Tomar tres medidas de voltaje entre los RECEPTOR UNIVERSAL siguientes puntos R1 R2 R1 tierra de chasis y R2 tierra de R2 tierra de chasis PARA DETECTAR DA O chasis El lugar de instalaci n depender del tipo de operador Consultar el manual de instrucciones R1 R2 R2 est puenteado a Si no se midiera voltaje entre R1 R2 verificar que el fusible tierra del transformador no estuviera quemado Si el fusible R1 tierra de chasis Vez secci n PROBAR EL estuviera quemado cambiarlo por el fusible del juego y volver RECEPTOR UNIVERSAL a medir el voltaje R2 tierra de chasis PARA DETECTAR DA O mediciones de voltaje tomadas PROBAR EL RECEPTOR UNIVERSAL PARA DETECTAR DANO Podria ser necesario cambiar el receptor universal instalado modelo 850LM Para probar el receptor universal Desconectar la alimentaci n el ctrica del operador Desconectar del operador el receptor universal Poner el selector del voltimetro digital para medir resistencia Conectar el negativo cable negro del voltimetro al conector F de conexi n a tierra de la antena del receptor universal 5 Conectar el positivo cable rojo del voltimetro a a La entrada positiva de alimentaci n del receptor universal Si el mult metro mide 0 O significa que hay un cortocircuito y el receptor est da ado Cambiar el receptor unive
8. ntaci n el ctrica y probar el funcionamiento del operador Doccceece Entrada de alimentaci n Entrada de alimentaci n Chasis Conector F Arandela plana de nailon 0 A la antena Arandela de nailon con resalto 8 2015 LiftMaster All Rights Reserved Tous droits r serv s 01 37828 Todos los derechos reservados
9. ondelle paulement doit aller l int rieur de l actionneur La rondelle plate doit aller l ext rieur de l actionneur Voir l illustration pour l ordre d assemblage 8 Reconnecter les c bles coaxiaux au connecteur F 9 Connecter la masse de l antenne au ch ssis 10 Connecter tous les autres accessoires conform ment aux instructions qui les accompagnent 11 Restaurer l alimentation l actionneur et tester ce dernier Co cu nel Do OMORONOMOMONO Entr e d alimentation Entr e d alimentation Chassis Connecteur F 0 Rondelle plate Vers l antenne en nylon Rondelle paulement en nylon 8 Juego de aislamiento de antena K001A3200 2 APLICACI N A ADVERTENCIA El juego de aislamiento de antena protege a los componentes del operador del port n contra la posibilidad de da o que podr an Para reducir el riesgo de LESIONES GRAVES o la MUERTE causar ciertos tipos de conexi n La instalaci n de ciertos e Desconectar la alimentaci n el ctrica a la caja de fusibles accesorios exige que una de las salidas del transformador sea ANTES de continuar puenteada a la tierra del chasis Esto podr a quemar el fusible del e TODAS las conexiones el ctricas DEBEN ser realizadas por transformador o da ar el receptor universal LiftMaster NO un t cnico capacitado recomienda conectar la salida del transformador a la tierra del E Al finaliz
10. rsal b La entrada negativa de alimentaci n del receptor universal Si el mult metro mide 0 Q significa que hay un cortocircuito y el receptor est da ado Cambiar el receptor universal NOTA No confundir 0 Q con Q 6 Si el voltimetro no indicara un cortocircuito puede utilizar el receptor universal Pon INSTALAR EL JUEGO DE AISLAMIENTO Para instalar el juego de aislamiento 1 Desconectar la alimentaci n el ctrica del operador 2 Desconectar todos los accesorios del operador 3 Ubicar el conector F montado en el chasis adonde la antena coaxial pasa por el chasis del operador El lugar de instalaci n depender del tipo de operador Consultar el manual de instrucciones 4 Desconectar los cables coaxiales de ambos lados del conector F 5 Quitar el conector F y los accesorios de montaje Hacerlos a un lado para volver a instalarlos 6 Hacer un orificio con una broca de 1 2 de pulg 7 Volver a instalar el conector F en el chasis Colocar las arandelas de aislamiento entre el chasis y el resto de los accesorios de montaje La arandela con resalto debe quedar del lado interno del operador La arandela plana debe quedar del lado externo del operador V ase en la ilustraci n el orden de montaje 8 Conectar los cables coaxiales al conector PF 9 Conectar la tierra de antena al chasis 10 Conectar los dem s accesorios seg n sus propias instrucciones 11 Conectar la alime
11. ttre la masse l antenne du r cepteur universel 5 Connecter la borne positive ou rouge du voltm tre a l entr e d alimentation du r cepteur universel Si le voltmetre lit 00 c est qu il y a un court circuit indiquant que le r cepteur universel est endommag Remplacer le r cepteur universel b l entr e d alimentation du r cepteur universel Si le voltmetre lit 00 c est qu il y a un court circuit indiquant que le r cepteur universel est endommag Remplacer le r cepteur universel REMARQUE Ne pas confondre 00 et Q 6 Sile voltm tre n indique pas de court circuit le r cepteur universel peut tre utilis INSTALLER LE N CESSAIRE D ISOLATION Pour installer le n cessaire d isolation 1 D connecter l alimentation l actionneur 2 D poser tous les accessoires de l actionneur 3 Localiser le connecteur F mont sur le ch ssis o l antenne coaxiale passe par le ch ssis de l actionneur L emplacement varie en fonction de l actionneur consulter cet effet le manuel du propri taire 4 D connecter les c bles coaxiaux des deux c t s du connecteur F 5 D poser le connecteur F et la visserie de montage Les mettre de c t pour la r installation 6 Percer un trou l aide d une m che de 1 2 po 7 R installer le connecteur F sur le ch ssis Ins rer les rondelles d isolation entre le ch ssis de l actionneur et l autre visserie La r
12. ur installation R1 R2 Neither of the 1 Disconnect power to the operator See ar transformer outputs are 2 Disconnect the universal receiver model 850LM from the A grounded operator Location varies depending on the operator refer to The isolation kit is NOT the owner s manual R2 chassis ground needed 3 Connect all other accessories according to the instructions that came with them R1 R2 R1 is shunted to ground 4 Restore power to the operator Proceed to TEST THE 5 Configure a digital voltmeter to measure AC voltage Make 3 R1 chassis ground UNIVERSAL RECEIVER voltage measurements between the following points R1 R2 FOR DAMAGE R1 chassis ground and R2 chassis ground Location varies R2 chassis ground depending on the operator refer to the owner s manual If there is no voltage between R1 R2 check to see if the transformer fuse is blown If the fuse is blown replace with the appropriate fuse included in the kit and measure voltage again R2 chassis ground R1 R2 R2 is shunted to ground E Proceed to TEST THE R1 chassis ground UNIVERSAL RECEIVER FOR DAMAGE your set of voltage measurements TEST THE UNIVERSAL RECEIVER FOR DAMAGE You may need to replace the pre installed universal receiver model 850LM To test the universal receiver for damage 1 Disconnect power to the operator 2 Disconnect the universal receiver from the operator 3 Configure a digital voltmeter to measure resist