1. Robinet de lavabo MAXLINE vanne RESERVOIR D EAUCHAU y Alimentation en Alimentation en FOURNAISE a ae ETC eau mod r e eau mod r e Alimentation Alimentation en eau chaude principale en eau froide Diagramme d appareils multiples Robinets simples Robinets doubles si n cessaire pour la lessive etc w7 Gp vanne gt DA no 7s Alimentation en eau mod r e Alimentation en eau chaude a temp rature lev e RESERVOIR D Thermom tr D EAUCHAU ASE recommand DE MAXLINE FOURNAISE a ETC A Ro Alimentation en eau froide Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 T l copieur 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 97 80e 99 SYMMONS 7 210 CK Maxline Manuel d op ration et d entretien Op ration et entretien Inspection initiale dans les 30 jours Inspectez la cartouche dans les 30 jours suivant l op ration initiale Si inspection d termine que votre syst me d eau cause des d p ts et qu une mati re trang re se forme ajustez l entretien de la cartouche en cons quence Remplacement de la cartouche 1 teignez les approvisionnements d eau chaude et froide la vanne 2 Retirez le bouchon de s curit en ins rant un petit tournevis dans la fente la plus large la base du bouchon
2. ZV 3010 REV D 05 27 14 aad aad 9 SYMMONS 7 210 CK Maxline Operation amp Maintenance Manual Operation amp Maintenance Initial 30 Day Inspection Inspect cartridge within 30 days of initial operation If inspection determines that your water system is causing deposits and foreign matter to build up then adjust cartridge maintenance accordingly Cartridge Replacement 1 Shut off hot and cold water supplies to valve 2 Remove safety cap by inserting a small screwdriver into the widest opening at the base of the cap and pry upward This will expose the cartridge stem and cartridge retaining unit 3 Remove retaining nut by turning counter clockwise with adjustable wrench Grasp cartridge with pliers and remove from body by pulling straight out A slight rocking rotation may be required to loosen while removing 4 Lubricate cartridge o rings with a small amount of lubricant prior to reinstalling Insert replacement cartridge into valve body applying enough force to ensure cartridge is fully seated Install cartridge with keyway inline with the front of the valve as retaining nut Torque to 132 inch lbs 15Nm E shown below to the left Install retaining nut back onto valve body 5 Refer to Setting Valve Temperature section pg 3 to properly set valve to desired temperature Service Instructions Cleaning or replacing screen amp check 1 Remove compression nut an
3. consultez votre repr sentant local ou le service a la clientele Symmons Installation de la vanne 1 Rincez bien le tuyau avant l installation 2 Installez la vanne de sorte a permettre une distance pour remplacer la cartouche La vanne peut tre install e dans tous les sens 3 Connectez l entr e la sortie de la vanne pour approvisionner les ports a Entr e d eau chaude marqu e H b Entr e d eau froide marqu e C c Entr e de sortie mixte marqu e M gt bouchon NE de s curit crou de retenue D gagement 3 1 2po __ cartouche de la vanne 89 mm corps de vanne montr sans les raccords de vanne R glage de la temp rature de la vanne 1 Ouvrez l approvisionnement en eau chaude et froide 2 Ouvrez le robinet pour permettre l eau chaude de couler pendant une ou deux minutes Pour les robinets deux poign es ouvrez uniquement l eau chaude Pour les robinets poign e simple ouvrez la position d eau chaude 3 Retirez le bouchon de s curit en ins rant un petit tournevis plat dans la large fente la base du bouchon et forcez vers le haut puis retournez le bouchon de s curit 180 degr s et ajustez l extr mit de la tige de la vanne Bouchon de s curit Ajustement de la temp rature 4 Placez le thermom tre dans la d charge Mesurez et r glez de mani re appropri e la temp rature La temp rature d entr e doit
4. et forcez vers le haut Ceci exposera la tige de la cartouche et l unit retenant la cartouche 3 Retirez l crou de serrage en tournant dans le sens antihoraire l aide d une cl ajustable Agrippez la cartouche avec des pinces et retirez du corps en tirant directement Une l g re rotation peut tre requise pour la desserrer tout en la retirant 4 Lubrifiez les anneaux de la cartouche avec une petite quantit de lubrifiant avant la r installation Ins rez une cartouche de remplacement dans le corps de la vanne en appliquant suffisamment de force pour s assurer que la cartouche est bien enclench e Ins rez la cartouche avec une rainure en ligne avec le devant de la vanne comme montr plus bas la gauche R installez l cran de maintien sur le corps de la vanne ecrou de retenue Couple jusqu 132 pouce lb 15Nm ES 5 Se r f rer la section R gler la temp rature de la vanne p 3 pour r gler de mani re appropri e la vanne la temp rature d sir e Instructions de service Nettoyage et remplacement de l cran et contr le 1 Retirez l crou de compression et l adaptateur de compression du corps de la vanne 2 Nettoyez l cran de l adaptateur de compression en les faisant tremper dans le vinaigre maison et rincez l eau courante Ne retirez pas l cran de l adaptateur de compression pour le nettoyage ou il peut tre facilement endomm
5. instalarla 2 Instale la v lvula con el fin de dejar distancia para la sustituci n de cartucho La v lvula se puede instalar en cualquier orientaci n 3 Conecte la entrada salida de la v lvula a los puertos de suministro a Puerto de agua caliente marcado H b Puerto de agua fr a marcada C c Puerto de salida mixta marcado M Tapa de seguridad Tuerca de retenci n Distancia 3 1 2 4 Cartucho de la v lvula 89 mm PE D Cuerpo de la v lvula se muestra sin accesorios de la v lvula O Ajuste de temperatura de la v lvula 1 Abra el suministro de agua caliente y fr a 2 Abra el grifo para que el agua caliente fluya durante al menos un minuto En los grifos de dos canillas abra el agua caliente solamente En el caso de grifos mono comando g relos a la posici n de caliente 3 Extraiga la tapa de seguridad mediante la inserci n de un destornillador plano peque o en la ranura ancha en la base de la tapa y haga palanca hacia arriba luego voltee la tapa de seguridad 180 grados y col quela en el extremo del eje de la v lvula Tapa de seguridad Regulaci n de temperatura 4 Coloque el term metro en el flujo de salida Mida y regule la temperatura con precisi n La temperatura de entrada debe ser de 10 F 5 55 C de la salida deseada 5 A fin de aumentar la temperatura gire la tapa de seguridad a la izquierda Para disminuir la
6. less than normal Check valve sealed allowing cold water to mix with hot is not completel p y Remove screen check valve and Water continues to run colder than original temperature setting clean under running water Valve is leaking around the cap retaining nut area l igh Replace o ring by ordering Water leaking from o ring seal cartridge replacement kit Hot water supply into valve is not 10 F 5 55 C above desired set ineteane nor water Supply temperature into valve point temperature Tempered hot water temperature is not hot enough Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 0 aad SYMMONS the smart choice 7 210 CK Maxline Manual de funcionamiento y mantenimiento Numero de modelo Especificacion O 7 210 CK Conexiones Accesorios de compresi n de 3 8 La v lvula limitadora de temperatura del agua que incluye v lvulas antirretorno integrales y dos tamices de acero inoxidable para una doble protecci n contra Modificaciones O B 04040 Nota Anexe el sufijo apropiado al n mero del modelo Gabinete de pared en acabado de esmalte blanco que incluye soporte de montaje en pared 3 8 de montaje de compresi n Chapado en n quel Gabinete de acero inoxidable Soporte de montaje en pared pa
7. temperatura gire la tapa de seguridad a la derecha Para aplicaciones de temperatura nica regule la temperatura de salida de la v lvula con el flujo m ximo de agua templada del accesorio Para aplicaciones de temperatura doble abre aproximadamente el 50 de todos los grifos a su posici n de calor m ximo para garantizar la temperatura de funcionamiento adecuada a la demanda pico 6 Extraiga la tapa de seguridad de extremo del eje de la v lvula y volt ela 180 grados a continuaci n presione la tapa hacia abajo y enc jela a presi n de nuevo sobre el cuerpo de la v lvula para reemplazar Nota Una vez que la tapa de seguridad est encajada a presi n sobre el cuerpo de la v lvula la temperatura de salida no se puede cambiar sin repetir los pasos 2 a 6 Advertencia Las temperaturas del agua superiores a 110 F 43 C pueden causar quemaduras o lesiones graves A Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 vo aad 99 SYMMONS 7 210 CK Maxline Manual de funcionamiento y mantenimiento Instalaci n Diagrama de punto de uso Grifo de Grifo de lavatorio cocina V lvula MAXLINE MAXLINE TANQUE DE valvula AGUA V1 CALIENTE D o Suministro de agua Suministro de agua caliente templada caliente templada o S
8. tre 10 F 5 55 C de la temp rature de sortie d sir e 5 Pour augmenter la temp rature tournez le bouchon de s curit dans le sens antihoraire Pour diminuer la temp rature tournez le bouchon de s curit dans le sens horaire Pour les applications de temp rature simple ajustez la temp rature de sortie de la vanne avec un d bit complet d eau mod r sur raccord Pour les applications de temp ratures doubles ouvrez environ 50 de tous les robinets leur position d eau chaude pour assurer une temp rature appropri e lors d une forte demande 6 Retirez le bouchon de s curit depuis l extr mit de la tige de la vanne et le retourner 180 degr s puis appuyez une pression sur le bouchon et le remettre sur le corps de la vanne pour le remplacer Remarque Une fois le bouchon de s curit fix sur le corps de la vanne la temp rature de sortie ne peut tre modifi e sans r p ter les tapes 2 6 Avertissement Les temp ratures d eau sup rieure 110 F 43 C peuvent causer des br lures ou des blessures graves 15 Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 T l copieur 800 961 9621 2013 Symmons Industries Inc www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 16 0 aad 9 SYMMONS 7 210 CK Maxline Manuel d op ration et d entretien Installation Diagramme du point d utilisation
9. 0 80e 9 SYMMONS 7 210 CK Maxline Operation amp Maintenance Manual Model Number Specification O 7 210 CK Connections 3 8 compression fittings Modifications O B Wall cabinet in white enamel finish including wall mounting bracket O D 3 8 compression fitting to allow water bypass for hot and cold supply faucet O NI Nickel plated O T Stainless steel cabinet in place of standard white cabinet O W Wall mounting bracket Note Append appropriate suffix to model number Compliance Water temperature limiting valve including integral checks and dual stainless steel strainers for double protection against suspended particles in supply lines Valve made from lead free metal components see table 1 for flow rates Temperature control range 59 F 113 F 15 C 45 C Minimum supply pressure 20 psi 138 kPa Maximum supply pressure 125 psi 862 kPa Inlet to outlet temperature differential 10 F 5 55 C According to US Senate bill S 3874 the term lead free is defined as follows not more than a weighted average of 0 25 percent lead when used with respect to the wetted surfaces of pipes pipe fittings plumbing fittings and fixtures Warranty ASME A112 18 1 CSA B125 1 ASSE 1017 CSA B125 3 ASSE 1070 CSA B125 3 CA 116875 AB 1953 NSF ANSI 61 9 NSF ANSI 372 No C 5 Years for commercial installations Refer to www symmons com warranty for complet
10. ag 3 Remplacez l cran en le retirant depuis le centre de l adaptateur de compression 4 Remplacez le contr le en le retirant du centre de la connexion du corps de la vanne Utilisation saisonni re Si la vanne est utilis e saisonni rement comme dans les coles et les campings effectuez les tapes suivantes pour viter les dommages caus es par l eau surgel e lorsque les vannes ne sont pas utilis es 1 teignez les approvisionnements d eau chaude et froide 2 Retirez la cartouche de la vanne et drainez toute l eau 3 Drainez l eau depuis les conduites d alimentation et le corps de la vanne Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 T l copieur 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 0 aad 9 SYMMONS 7 210 CK Maxline Manuel d op ration et d entretien Entretien et nettoyage Retirez la cartouche et nettoyez le corps de la vanne dans le vinaigre maison pour retirer l accumulation de min ral corrosif Rincez sous l eau chaude courante pour s assurer que la vanne ne contient aucun d bris tranger Tableau de probl mes Probl me Solution 1 Retirer le filtre et nettoyez le sous l eau courante Le d bit de l eau est inf rieur Le filtre de la vanne est sale ou la 2 Retirer lacartoucheet nettoyez la la normale cartouche est sa
11. aliente La malla de la v lvula est sucia o el cartucho est sucio u obstruido La v lvula de retenci n no est sellada completamente lo que permite que el agua fr a se mezcle con el agua caliente Fuga de agua en el sello del anillo de goma El suministro de agua caliente a la v lvula no est 10 F 5 55 C por encima de la temperatura de consigna deseada Soluci n 1 Quite la malla y limpiela con agua corriente 2 Retire el cartucho y limpielo con vinagre de cocina o sustit yalo mediante el pedido del kit de sustituci n del cartucho Quite la malla v lvula de retenci n y l mpiela con agua corriente Reemplace el anillo de goma mediante el pedido del kit de sustituci n de cartucho Aumente la temperatura del suministro de agua caliente a la v lvula Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 9189 00 SYMMONS the smart choice 7 210 CK Maxline Manuel d op ration et d entretien Num ro de mod le Sp cification O 7 210 CK Raccords Raccords de compression de 3 8 po Modifications O B Cabinet mural au fini mail blanc in cluant un support de montage mura O D 3 8 raccord compression O NI Plaqu en nickel O T Bo tier en acier inoxydable O Ww Support mural Remarque Joindre
12. d compression adapter from valve body 2 Clean screen seated in compression adapter by soaking both in household vinegar and rinse under running water Do not remove screen from compression adapter to clean or it can easily be damaged 3 Replace screen by pressing out from center of compression adapter 4 Replace check by removing from center of valve body connection Seasonal Use If valve is used seasonally such as in schools or campgrounds then perform the following steps to avoid damage caused by freezing water when valves are not in use 1 Shut off hot and cold water supplies 2 Remove valve cartridge and drain all water 3 Drain water from the supply lines and valve body Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 9899 aad 9 SYMMONS 7 210 CK Maxline Operation amp Maintenance Manual Care and Cleaning Remove cartridge and clean valve body in household vinegar to remove corrosive mineral build up Rinse under running hot water to ensure valve is free of foreign debris Trouble Shooting Chart Problem Solution 1 Remove screen and clean under running water Screen in valve is dirty or cartridge is dirty or clogged 2 Remove cartridge and clean in household vinegar or replace by ordering cartridge replacement kit Water flow is
13. e warranty information US S 3874 Table 1 Flow Rate gpm L min Pressure Differential psi kPa Size Min Flow Valve Model Connection Rate 5 psi 10 psi 20 psi 25 psi 30 psi 45 psi 34 kPa 69 kPa 138 kPa 172 kPa 207 kPa 310 kPa 3 8 ere 0 5 gpm 1 0 gpm 2 0 gpm 3 0 gpm 3 5 gpm 4 0 gpm 5 0 gpm das epa 1 9 L min 3 8 L min 7 6 L min 11 4 L min 13 3 L min 15 2 L min 19 0 L min Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 9819 00 99 SYMMONS 7 210 CK Maxline Operation amp Maintenance Manual Dimensions Measurements 7 210 CK 4 1 2 114 mm 5 1 4 133 mm a A C 2 50 mm D 2 1 2 64 mm Note Dimensions are subject to change without notice Parts Breakdown Replacement Parts 7 210 CK Item Description A Safety cap TMX 301 B Cartridge TMX 249 KIT 3 8 compression fittings C including checks and TMX 104 LL KIT screens Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 vo 0 9 SYMMONS 7 210 CK Maxline Operation amp Maintenanc
14. e Manual Installation Sizing Valve For assistance in sizing and selection of the proper valve consult your local representative or Symmons Customer Service Installing Valve 1 Flush piping thoroughly prior to installing 2 Install valve so as to allow clearance for replacing cartridge Valve can be installed in any orientation 3 Connect valve input ouput to supply ports a Hot port marked H b Cold port marked C c Mixed output port marked M j Valve 3 1 2 clearance 89 mm valve body shown without valve fittings Setting Valve Temperature 1 Turn hot and cold water supply on 2 Open faucet to allow hot water to flow for a minimum of one minute For two handle faucets turn on hot water only For single handle faucets turn on to the hot position 3 Remove the safety cap by inserting a small flat tip screw driver into the wide slot at the base of the cap and pry upward then flip the safety cap over 180 degrees and fit onto the end of valve spindle Safety Cap Temperature Adjust 4 Place thermometer in the outlet stream Measure and accurately set temperature Inlet temperature must be 10 F 5 55 C of desired output 5 To increase temperature turn safety cap counter clockwise To decrease temperature turn safety cap clockwise For single temperature applications adjust valve outlet temperature with full flow of tempered water from fitting For dual
15. in 3 8 L min 7 6 L min 11 4 L min 13 3 L min 15 2 L min 19 0 L min Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 919 0 9 SYMMONS the smart choice 7 210 CK Maxline Manual de funcionamiento y mantenimiento Dimensiones Mediciones de 7 210 CK 4 1 2 114 mm 5 1 4 133 mm 2 50 mm 2 1 2 64 mm A mt a TY Nota Las dimensiones pueden cambiar sin previo aviso Desglose de partes Repuestos de 7 210 CK Tapa de seguridad TMX 301 Cartucho Accesorios de compresi n de 3 8 que incluyen v lvulas antirretorno y mallas TMX 249 KIT TMX 104 LL KIT Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 9899 aad 9 SYMMONS the smart choice 7 210 CK Maxline Manual de funcionamiento y mantenimiento Instalaci n Dimensionamiento de la v lvula Para obtener ayuda para el dimensionamiento y selecci n de la v lvula adecuada consulte a su representante local o al departamento de Atenci n al cliente de Symmons Instalaci n de la v lvula 1 Lave a fondo las tuber as antes de
16. kPa 207 kPa 310 kPa 7 210 CK Compression de 0 5 gpm 1 0 gom 2 0 gpm 3 0 gpm 3 5 gpm 4 0 gpm 5 0 gpm 3 8 po 10 mm 1 9 L min 3 8 L min 7 6 L min 11 4 L min 13 3 L min 15 2 L min 19 0 L min Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 T l copieur 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 14 0 00 9 SYMMONS 7 210 CK Maxline Manuel d op ration et d entretien Dimensions A Mesures 7 210 CK 4 1 2 po 114 mm 5 1 4 po 133 mm 2 po 50 mm 2 1 2 po 64 mm olojo gt Remarque Les dimensions sont sujettes changer sans pr avis Nomenclature des pi ces Article Pi ces de remplacement 7 210 CK Bouchon de s curit TMX 301 Cartouche TMX 249 KIT Raccords de compression de 3 8 po incluant les dispositifs d arr t et les filtres TMX 104 LL KIT Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 T l copieur 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 9189 00 9 SYMMONS 7 210 CK Maxline Manuel d op ration et d entretien Installation Dimension de la vanne Pour obtenir de l aide au niveau de la dimension et de la s lection de la vanne appropri e
17. le ou obstru e dans le vinaigre maison ou la remplacer en commandant une trousse de remplacement de la cartouche Assurez vous que la vanne soit enti rement scell e permettant l eau froide de se m langer l eau chaude L eau continue de couler plus froide que le r glage de la temp rature originale Retirer l cran v rifier la vanne et nettoyer sous l eau courante Remplacer l anneau encommandant L eau fuit depuis l anneau une trousse de remplacement de cartouche La vanne fuit autour du bouchon qui retient l crou L approvisionnement d eau La temp rature de l eau chaude mod r e chaude dans la vanne n est pas Augmenter la temp rature de l eau n est pas suffisamment chaude 10 F 5 55 C sup rieure la chaude dans la vanne temp rature d sir e Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 T l copieur 800 961 9621 2013 Symmons Industries Inc www symmons com gethelp symmons com ZV 3010 REV D 05 27 14
18. le suffixe appropri au num ro de mod le Conformit Vanne limitant la temp rature de l eau incluant des contr les int graux et des pommelles doubles en acier inoxydable pour offrir une protection double contre les particules suspendues dans les conduites d alimentation Vanne faite partir de composants en m tal sans plomb consultez le tableau 1 pour les d bits Port e du contr le de la temp rature 59 F 113 F 15 C 45 C Pression d approvisionnement minimale 20 psi 138 kPa Pression d approvisionnement maximale 125 psi 862 kPa Ecart de temp rature d entr e et de sortie 10 F 5 55 C Selon la loi du S nat am ricain S 3874 le terme sans plomb se d finit comme suit au maximum une moyenne 0 25 pour cent de plomb lorsqu utilis avec des surfaces de tuyaux raccords de tuyau raccords de plomberie et appareils humides Garantie ASME A112 18 1 CSA B125 1 ASSE 1017 CSA B125 3 ASSE 1070 CSA B125 3 CA 116875 AB 1953 NSF ANSI 61 9 NSF ANSI 372 US S 3874 C Z 5 ans pour les installations commerciales Se r f rer au www symmons com warranty pour les renseignements complets relatifs la garantie Tableau 1 D bit gom L min f Diff rentiel de pression psi kPa Mod le de la Connexion de la D bit min vanne dimension 5 psi 10 psi 20 psi 25 psi 30 psi 45 psi 34 kPa 69 kPa 138 kPa 172
19. rt culas en suspensi n en las l neas de suministro V lvula fabricada con componentes met licos libres de plomo ver la tabla 1 para informarse sobre las tasas de flujo Rango de control de temperatura 59 F 113 F 15 C 45 C Presi n minima de suministro 20 psi 138 kPa Presi n m xima de suministro 125 psi 862 kPa Diferencial de temperatura entre entrada y salida 10 F 5 55 C De acuerdo con el proyecto de ley del Senado de los EE UU S 3874 el t rmino libre de plomo se define de la siguiente manera no m s que un promedio ponderado de 0 25 por ciento de plomo cuando se utiliza con respecto a las superficies h medas de tuber as accesorios de tuber a accesorios de fontaner a y artefactos Cumplimiento Garant a ASME A112 18 1 CSA B125 1 ASSE 1017 CSA B125 3 ASSE 1070 CSA B125 3 CA 116875 AB 1953 NSF ANSI 61 9 NSF ANSI 372 V 5 a os para instalaciones comerciales Consulte www symmons com warranty para obtener informaci n completa sobre la garant a US S 3874 Tabla 1 Tasa de flujo gpm L min Dif ial d i n psi kP Modelo de Tama o de la Tasa de flujo IAE presiolt Paihia valvula conexion min 5 psi 10 psi 20 psi 25 psi 30 psi 45 psi 34 kPa 69 kPa 138 kPa 172 kPa 207 kPa 310 kPa 7 210 CK Compresi n de 0 5 gpm 1 0 gpm 2 0 gpm 3 0 gpm 3 5 gpm 4 0 gpm 5 0 gpm 3 8 10 mm 1 9 L m
20. temperature applications open approximately 50 of all faucets to their full hot position to ensure proper operating temperature at peak demand 6 Remove safety cap from end of valve spindle and flip over 180 degrees then press cap down and snap back onto valve body to replace Note Once the safety cap is snapped onto the valve body the outlet temperature cannot be changed without repeating steps 2 6 Warning Water temperatures in excess of 110 F 43 C may cause scalding or severe injury Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 919 9 99 9 SYMMONS 7 210 CK Maxline Operation amp Maintenance Manual Installation Point of Use Diagram Lavatory Kitchen faucet faucet MAXLINE MAXLINE valve valve valve valve V1 V2 Tempered Tempered hot supply hot supply Main hot supply Cold supply Multiple Fixtures Diagram Single supply faucets Two supply faucet if required for laundry etc Ee ww valve gt p lt me Tempered hot supply High temperature hot supply Thermometer recommended MAXLINE A valve Cold supply Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com
21. tenci n gir ndola hacia la izquierda con una llave regulable Sujete el cartucho con pinzas y extraiga del cuerpo tirando hacia fuera Una ligera rotaci n oscilante puede ser necesaria para aflojarlo mientras lo extrae 4 Lubrique los anillos de goma del cartucho con una peque a cantidad de lubricante antes de su reinstalaci n Inserte el cartucho de repuesto en el cuerpo de la v lvula mediante la aplicaci n de la fuerza suficiente para garantizar que el cartucho est completamente asentado Instale el cartucho con el chavetero en l nea con la parte delantera de tuerca de retenci n la v lvula como se muestra abajo a la izquierda Instale la tuerca de retenci n de nuevo en el cuerpo de la v lvula 5 Consulte la secci n Configuraci n de la temperatura de la v lvula p g 3 para configurar correctamente la v lvula a la temperatura deseada Instrucciones de servicio Limpieza o sustituci n de la malla y v lvula antirretorno 1 Quite la tuerca de compresi n y el adaptador de compresi n del cuerpo de la v lvula 2 Limpie la malla asentada en el adaptador de compresi n mediante la inmersi n de ambos en vinagre de cocina y enjuague con agua corriente No quitar la malla del adaptador de compresi n para limpiarla o se puede da ar con facilidad 3 Vuelva a colocar la malla presionando hacia afuera desde el centro del adaptador de compresi n 4 Coloque nuevamente la v lvula an
22. tirretorno mediante la extracci n del centro de la conexi n del cuerpo de la v lvula Uso estacional Si se utiliza la v lvula estacionalmente como por ejemplo en escuelas o lugares para acampar entonces lleve a cabo los siguientes pasos para evitar da os causados por la congelaci n del agua cuando las v lvulas no est n en uso 1 Cierre los suministros de agua caliente y fr a 2 Extraiga el cartucho de la v lvula y drene toda el agua 3 Realice el drenaje del agua de las tuber as de suministro y el cuerpo de la v lvula Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 12 0 aad SYMMONS the smart choice 7 210 CK Maxline Manual de funcionamiento y mantenimiento Cuidado y limpieza Extraiga el cartucho y limpie el cuerpo de la v lvula en vinagre de cocina para eliminar la acumulaci n de minerales corrosivos Enjuague bajo un chorro de agua caliente para asegurar la v lvula est libre de materiales extra os Tabla de soluci n de problemas Problema El flujo de agua es menor de lo normal El agua sigue corriendo m s fr a que la configuraci n original de temperatura La v lvula tiene una fuga en la zona de la tuerca de retenci n de la tapa La temperatura del agua caliente templada no est lo suficientemente c
23. uministro Suministro principal de agua caliente de agua fr a Diagrama de varios artefactos Suministro de agua caliente Grifo de suministro individual Grifos de dos suministros a alta temperatura si fuese necesaria para lavaderos etc 8 8 v lvula D bd st me Suministro de agua caliente templada O Term metro recomendado A V lvula MAXLINE Suministro de agua fr a Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2013 Symmons Industries Inc s www symmons com gethelp symmons com ZV 3010 REV D 05 27 14 0 00 9 SYMMONS the smart choice 7 210 CK Maxline Manual de funcionamiento y mantenimiento Funcionamiento y mantenimiento Inspecci n dentro los 30 dias del inicio del funcionamiento Inspeccione el cartucho dentro de los 30 dias del inicio del funcionamiento Si la inspecci n determina que el sistema de agua causa dep sitos y acumulaci n de materiales extra os entonces ajuste el mantenimiento del cartucho de manera acorde a tal hecho Reemplazo del cartucho 1 Cierre los suministros de agua caliente y fr a a la v lvula 2 Extraiga la tapa de seguridad mediante la inserci n de un destornillador plano peque o en la ranura m s ancha en la base de la tapa y haga palanca hacia arriba Esto expondr el v stago del cartucho y la unidad de retenci n de dicho cartucho 3 Quite la tuerca de re