1. FREQUENCY CHARACTERISTICS Range HF 10Hz to 25MHz VHF 10MHz TO 200MHz Accuracy 1 0 Sec Gate Time base accuracy 1 count 0 1 Sec Gate Time base accuracy 2 counts Resolution 1 0 Sec Gate 1Hz 0 1 Sec Gate 10Hz INPUT CHARACTERISTICS IMPEDANCE HF 1 VHF 500 Connector BNC Coupling D6 Sinewave Sensitivity 50mVrms 10Hz to 200MHz Maximum Input 3V TIME BASE CHARACTERISTICS Type Crystal Oscillator Frequency 5 24288MHz Stability 10ppm Temperature Stability lt 0 001 10ppm 0 500 Maximum Aging Rate l0ppm year SPECIFICATIONS DISPLAY CHARACTERISTICS Display 0 43 LEDs Overflow Indicator OVERflow indicator top left corner of display lights when count exceeds 199 9999 counts Display Update Time 1 0 Sec Gate 2 0 seconds 0 1 Sec Gate 0 2 seconds GENERAL Power AC Adaptor 7 10V with 500mA Temperature Range amp Humidity Operation 0 to 50C 85 R H Storage 15C to 70 lt 75 Dimensions HxWxD 2 1 X 9 06 X 6 18 54 X 230 X 157mm Weight 0 8Kgs 1 761 bs Accessories Supplied Instruction Manual BNC to Clip cable NOTE Specifications and information are subject to change without notice Please visit www bkprecision com for the most current product
2. information Qv US A See CONTROLS amp INDICATORS Input Jack Input jack for 10Hz to 200MHz frequency measurements Display Seven digit display used for all frequency readings OVERflow Indicator Lights whenever range of display is exceeded 199 99999MHz Most significant digit is not displayed Frequency Function Switch Selects VHF and HF frequency range at input jack Gate Time Switch Selects gate time 0 1 second and 1 0 second POWER Switch Turns power ON and OFF CONTROLS AND INDICATORS PARARE FREQUENCY COUNTER HF 10 2 20 2 20 2 200 2 MHz VHF JS VHF 7 1 05 HF FREQ RANGE OPERATING INSTRUCTIONS WARNING Some operating conditions may pose electrical shock hazard Know and observe the precautions described in the Test Instrument Safety section 2 Connect the AC Adapter to an ac outlet and plug into the rear panel jack of the frequency counter 3 Set the POWER GATE TIME switch to 0 IS or 1 0 S a Use 0 15 for faster measurement of high frequency signals The update time of the display is every 0 2 second Resolution is 10Hz b Use LOS for measurement of low frequencies or where highest resolution is needed The update time of the display is every 2 seconds Resolution is 1Hz 4 Apply the 10Hz to 200MHz signals to be measured to the input jack CAUTION To prevent damage to the unit do not apply input volta
3. n es de 10Hz como 012000 y 12MHz como 12 000000 b Con un tiempo de 0 15 todas las lecturas son en Mhz con un d gito menos de resoluci n Por ejemplo 12KHz se muestra como 0 01200 y b Use 1 0S para mediciones de frecuencias bajas o para mayor resoluci n El tiempo de actualizaci n es de 2 seg La resoluci n es de 12MHz como 12 000000 5 Elintervalo de medici n tiempo de compuerta es 1 0 segs 3 Aplique las se ial a medir al jack de entrada or 0 1 seg Este se combina con el intervalo adicional de igual tiempo de reajuste interno para un total de 2 segundos entre actualizaci n de pantalla al seleccionar 1 0S o 0 2 segs 21 al seleccionar tiempo de compuerta de 0 1 seg FREQUENCY COUNTER HF 10 2 20 2 VHF 20 2 200 2 MHz VHF je E FREQ RANGE CONSIDERACIONES Inestabilidad de pantalla Una inestabilidad de 1 d gito menos significativo es inherente en todas las mediciones digitales y pueden existir incertidumbres a causa de otros factores como el ruido de alta frecuencia en mediciones de baja frecuencia o inestabilidad de la frecuencia de entrada com n en osciladores del tipo LC Uso de antena Para medir frecuencia de transmisores no es siempre necesaria una conexi n directa al transmisor De hecho el contador debe protegerse contra niveles excesivos de potencia Se prefiere el m todo de conectar una antenna a la entrada del contador El
4. AS DE BASE DE TIEMPO Tipo Oscilador a cristal Frecuencia 5 24288MHz Estabilidad 0 1 Estabilidad de temperatura lt 0 001 10ppm 0 500 C Raz n de envejecimiento loppm year m ximo ESPECIFICA CIONES CARACTERISTICAS DE PANTALLA ceres 0 43 LEDs Indicador de sobreflujo Indicador OVERflow Esauina superior izquierda enciende cuando la cuenta exceed de 199 9999 Tiempo de actualizaci n de pantalla GENERAL Potencia Adaptador AC Rango de temperatura amp humedad Operaci n Almacenamiento Compuerta 1 0 Seg 2 0 segundos Compuerta 0 1 Sec 0 2 segundos SS 7 10V con 500mA 0a 450C 85 RH Dada 2 15C a 70 lt 75 R H 2 1 X 9 06 X 6 18 54 X 230 X 157mm 0 8Kgs 1 761 Ibs Manual de usuario Cable BNC a Clip NOTA Las especificaciones y la informaci n est n conforme a cambio sin el aviso de B amp K Precision Corp Por favor visite www bkprecision com para las especificaciones m s corriente y informaci n de nuestros productos 19 CONTROLS AND INDICATORS 7 Jack De entrada Entrada para mediciones de frecuencia de 10Hz a 200MHz 8 Pantalla De siete d gitos para todas las frecuencias 9 OVERfIow Indicador Enciende al excederse el rango 199 990999MHzNo se muestra el d gito m s significativo 10 Switch de function de frecuencia Seleccciona rangos de frecuenci
5. BK Precision Model PT 21 Antenna Kit es ideal para usarse con el Modelo I803d para medir frecuencias de 20MHz a 200MHz La antena debe colocarse en paralelo con la antenna transmisora separada por unas cuantas pulgadas La distancia espec fica se determina por el nivel de potencia del transmisor Algunos transmisores de muy baja potencia pueden no proveer una se al suficiente para la medici n con este m todo se debe transmitir una portadora no modulada y la frecuencia aparecer en pantalla del contador Consideraciones de cable Las conexiones de cables en mediciones de alta frecuencia deben efectuarse para reducer ondas estacionarias y eliminar capacitancia paralelo las cuales afectan la precisi n de la medici n Las ondas estacionarias se minimizan pareando la impedancia de la fuente de entrada con la del cable y la terminaci n Por ejemplo para una fuente de 50 ohms use cable de 50 ohms y una carga terminal resistiva de 50 ohms Tanto las ondas estacionarias como 1 capacitancia paralelo pueden reducirse con cables cortos de menos de 3 pies 91cm Informaci n de Servicio Servicio de Garant a Por favor regrese el producto en el empaquetado original con prueba de la fecha de la compra a la direcci n debajo Indique claramente el problema en escritura incluya todos los accesorios que se estan usado con el equipo Servicio de No Garant a Por favor regrese el producto en el empaquetado original con prueba de la fe
6. INSTRUCTION BK PRECISION MANUAL Model 1803D MANUAL DE INSTRUCCIONES Modelo 1803D 200 MHz FREQUENCY COUNTER 200 MHz CONTADOR DE FRECUENCIA TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed high voltage is present An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can produce a lethal current under certain conditions Higher voltages are even more dangerous Your normal work habits should include all accepted practices to prevent contact with exposed high voltage and to steer current away from your heart in case of accidental contact with a high voltage Observe the following safety precautions 1 There is little danger of electrical shock from the dc output of this power supply because it can source 60 Vdc There are several other possible test conditions using this power supply that can create a high voltage shock hazard a If the equipment under test is the hot chassis type a serious shock hazard exists unless the equipment is unplugged just turning off the equipment does not remove the hazard or an isolation transformer is used b If the equipment under test is powered up and that equipment uses high voltage in any of its cir
7. a VHF y HF en el jack de entrada 11 Switch de tiempo de compuerta Seleccciona tiempo de 0 1 segundo y 1 0 segundo 12 POWER Switch Encendido ON and OFF 20 CONTROLS AND INDICATORS INSTRUCTIONES DE OPERACION ADVERTENCIA PRECAUCION Para prevenir da os a la unidad no aplique voltajes de entrada Algunas condiciones de operaci n pueden producir un riesgo superiores al l mite establecido en la secci n de de choque el ctrico Conozca y observe las precauciones Especificaciones Conecte la tierra del instrumento s lo a descritas en la secci n Seguridad del instrumento de prueba puntos de cero voltas del circuito bajo prueba No pretenda flotar la unidad pues se genera un riesgo de dado que la tierra del instrumento est expuesta en el conector frontal BNC Al 1 Conecte el adaptador de AC a un enchufe AC e ins rtelo medir la frecuencia de la l nea de AC observe las precauciones en el jack del panel trasero del contador De frecuencia enlistadas en el p rrafo Medici n del voltaje de l nea 4 La frecuencia se muestra en pantalla El punto decimal se 2 Fijeel POWER GATE TIME switch a 0 15 o 1 0 S posiciona autom ticamente a Use 0 15 para mediciones m s r pidas de a Conun tiempo de 0 1s lecturas menores a IMHz se ales de alta frecuencia El tiempo de se muestran d cimas de MHz arriba de 1MHz se actualizaci n en pantalla es de 0 2 segundos muestran en Mhz Por ejemplo 12KHz se muestra La resoluci
8. aje de corriente alterna esta usualmente presente en algunos de los circuitos de entrada tal como el switch de encendido apagado fusibles transformador de poder etc Cualquier tiempo que el equipo este conectado un enchufe de ca B amp K Precision productos no estan autorizados en ninguna aplicaci n que incluya contacto directo entre nuestro producto y el cuerpo humano o para uso como un componente critico en un dispositivo o sistema de soporte de vida Aqui contacto directo se refiere a cualquier conexi n de o a nuestro equipo a trav s de cualquier cableado o mecanismo de cambio Un componente critico es un componente de un dispositivo o sistema de soporte de vida cual falla a funcionar puede esperar razonablemente causar una falla de el dispositivo o sistema o afectar su seguridad o eficacia Nunca trabaje solo Algvien debe de estar cerca para prestar ayuda si necesaria Entrenamiento en CPR cardio pulmonaria resucitaci n primeros auxilios es altamente recomendado Printed in Taiwan BK CISION 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com O 2007 B amp K Precision Corp PN 481 375 9 001
9. cha de la compra a la direcci n debajo Indique claramente el problema en escritura incluya todos los accesorios que se estan usado con el equipo Clientes que no tienen cuentas deben de incluir pago en forma de queque orden de dinero o numero de carta de cr dito Para los precisos mas corriente visite www bkprecision com y oprime service repair Vuelva toda la mercanc a a B amp K Precision Corp con el env o pagado por adelantado La carga global de la reparaci n para el servicio de la No Garant a no incluye el env o de vuelta El env o de vuelta a las localizaciones en norte americano es incluido para el servicio de la garant a Para los env os de noche y el env o del no Norte los honorarios americanos satisfacen el contacto B amp K Precision Corp B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Incluya con el instrumento la direcci n de vuelto para env o nombre del contacto n mero de tel fono y descripci n del problema Garant a Limitada de Un Ano B amp K Precision Corp Autorizaciones al comprador original que su productos y componentes ser n libre de defectos por el periodo de un ano desde el d a en que se compro B amp K Precision Corp sin carga repararemos o sustituir a nuestra opci n producto defectivo o componentes Producto devuelto tiene que ser acompa ado con prueba de la fecha del la compra en la forma de un recibo de las ventas Para obt
10. cuits the power supply outputs may be floated to the potential at the point of connection Remember that high voltage may appear at unexpected points in defective equipment Do not float the power supply output to more than 100 volts peak with respect to chassis or earth ground c If the equipment under test is off and that equipment uses high voltage in any of its circuits under normal operation discharge high voltage capacitors before making connections or tests Some circuits retain high voltage long after the equipment is turned off 2 Use only a polarized 3 wire ac outlet This assures that the power supply chassis case and ground terminal are connected to a good earth ground and reduces danger from electrical shock 3 Don t expose high voltage needlessly Remove housings and covers only when necessary Turn off equipment while making test connections in high voltage circuits Discharge high voltage capacitors after removing power continued on inside back cover TABLE OF CONTENTS page page TEST INSTRUMENT SAFETY inside front cover INSTRUMENT REPAIR 10 SPECIFICATION Sy ETHER 4 LIMITED ONE YEAR WARRANTY 11 CONTROLS AND INDICATORS 6 SPANISH 16 OPERATING INSTRUCTIONS eee 8 SPECIFICATIONS MODES FEATURES Gate Times 1 0 sec and 0 1 sec gates Displayz 7 digits
11. ener cobertura en los EE UU este producto debe ser registrado por medio de la forma de registro en www bkprecision com dentro de quince 15 d as de la compra de este producto Exclusiones Esta garant a no se aplica en el evento de uso en error o abuso de este producto o el resultado de alteraciones desautorizado o reparaciones La garant a es vac a si se altera se desfigura o se quita el n mero de serie B amp K Precision Corp no ser obligado a dar servicio por danos consecuente incluyendo sin limitaciones a danos resultando en perdida de uso Algunos estados no permiten limitaciones de da os fortuitos o consecuentes Tan la limitaci n o la exclusi n antedicha puede no aplicarse a usted Esta garant a le da ciertos derechos y pueden tener otros derechos cuales cambian estado por estado B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 SEGURIDAD DE EL EQUIPO DE PRUEBA Continua por dentro de portada Si es posible familiar cese con el equipo que va ha ser revisado y el lugar de los puntos de alto voltaje Pero recure que alto voltaje puede aparecer en puntos inesperados en equipo defectivo Use un piso de material insuflado o un largo insuflado tapete para parase en el y una superficie de trabajo insuflada el la cual pueda poner el equipo y asegurese que estas superficies no est n h medas o mojadas Cuando este probando equipo encendido por ca la linea de volt
12. ge higher that the limits listed in the Specifications section Connect the instrument ground lead only to zero volt points in the circuit under test Attempting to float the unit may result in a shock hazard since the instrument ground is exposed at the front panel BNC connector If measuring ac line frequency observe the precautions listed in the Line Voltage Measurement paragraph 1 Frequency is given by the front panel display The decimal point is automatically positioned a With a 1 0S gate time readings below 1MHz are given in decimal MHz above MHz they are in whole megahertz For example 12KHz is displayed as 012000 and 12MHz is 12 000000 b With a 0 15 gate time all readings are displayed in MHz and with one less digit resolution For example 12KHz is displayed as 0 01200 and 12MHzis 12 000000 5 Measurement interval or gate time is 1 0 second or 0 I second This is combined with an additional interval of equal time for internal latching and resetting for a total of 2 seconds between display updated when 1 0S gate time is selected or 0 2 seconds when 0 15 gate time is selected 6 The OVER flow indicator lights whenever the range of the display 199 9999MHz is exceeded CONSIDERATIONS Display Instability An uncertainty of 1 least significant digit is inherent in all digital measurements and greater uncertainties can result from other factors For example in low frequency measurements high fre
13. ipment 5 Use an insulated floor material or a large insulated floor mat to stand on and an insulated work surface on which to place equipment and make certain such surfaces are not damp or wet 6 When testing ac powered equipment the ac line voltage is usually present on some power input circuits such as the on off switch fuses power transformer etc any time the equipment is connected to an ac outlet 7 B K Precision products are not authorized for use in any application involving direct contact between our product and the human body or for use as a critical component in a life support device or system Here direct contact refers to any connection from or to our equipment via any cabling or switching means A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause failure of that device or system or to affect its safety or effectiveness 8 Never work alone Someone should be nearby to render aid if necessary Training in CPR cardio pulmonary resuscitation first aid is highly recommended 15 SEGURIDAD DE EL INSTRUMENTO DE PRUEBA PRECAUCIONES Uso normal de probado de prueba te espose a cierta cantidad de peligro por un choque el ctrico porque revisiones son algunas veces hechas donde hay alto voltaje descubierto Un choque el ctrico que cause 10 milliamps pasar a trav s del coraz n parar a la mayor a de los corazones humanos Voltaje tan baj
14. o hasta 30 voltios dc ou ac rms podr a ser considerado peligroso porque puede producir una corriente letal bajo ciertas condiciones Voltajes mas altos pueden ser aun mas peligrosos Tus h bitos normales de trabajo deben de incluir todas las practicas aceptadas para prevenir contacto con alto voltaje descubierto y dirigir corriente lejos de el coraz n en caso de contacto accidental con un alto voltaje Observe las siguientes medidas de seguridad 1 Hay poco peligro de un choque el ctrico de la salida de cd de esta fuente de poder Pero puede haber otras posibles condiciones de prueba que cuando usando esta fuente de poder se puede crear un peligro de un choque de alto voltaje e Si el equipo bajo prueba es de el tipo chasis caliente un serio peligro de choque existe al menos que el equipo este desconectado nada mas apagando el equipo no remueve el peligro o si un transformador de aislamiento es usado e Si el equipo bajo prueba esta prendido y este equipo usa alto voltaje en cualquiera de sus circuitos las salidas de la fuente de poder pueden ser flotadas a el potencial al el punto de conexi n Recuerden que el alto poder puede aparecer en puntos inesperados en equipo defectuoso No flote la salida de la fuente de poder por mas de 100 voltios pico con respecto al chasis o tierra e 51 el equipo bajo prueba esta apagado y este equipo usa alto voltaje en cualquiera de sus circuitos cuando en operaci n normal descarga alto v
15. oltaje capacitares antes de hacer conexiones o pruebas Algunos circuitos conservan alto voltaje mucho despu s que el equipo es apagado 2 Solo use una enchufe polarizada de 3 conductores Esto asegura que el chasis de la fuente de poder cubierta y la terminal de tierra est n conectadas a una buena tierra y reduce el peligro de un choque el ctrico 3 No se expone a alto poder innecesariamente Remueva cubiertas solo cuando mas necesario Apague el equipo cuando este haciendo conexiones de prueba en circuito de alto voltaje Descargue los capacitadotes despu s de que remueva el poder continua el la parte de atr s 16 TABLA DE CONTENIDO SEGURIDAD DE EQUIPO DE PRUEBA ESPECIFICACIONES CONTROLES AND INDICADORES INSTRUCTIONES DE OPERACION page Segunda de forros INFORMACION DE SERVICO GARANTIA LIMITADA DE UN 17 ESPECIFICACIONES MODOS CARACTERISTICAS Tiempo de compuerta 1 0 sec y 0 1 seg Pantalla 7 digitos CARACTERISTICAS DE FRECUENCIA HF 10Hz a 25MHz VHF 10MHz a 200MHz Rango Precisi n Compuerta 1 0 Seg Precisi n base de tiempo cuenta Compuerta 0 1 Seg Precisi n base de tiempo 2 cuentas Resoluci n Compuerta 1 0 Seg 1Hz Compuerta 0 1 Seg 10Hz 18 CARACTERISTICAS DE ENTRADA IMPEDANCIA HF 1MQ VHF 500 Conector BNC Acoplamiento D6 Sensitividad senoidal 50mVrms 10Hz a 200MHz Entrada m xima 3V CARACTERISTIC
16. quency noise on the input can cause miscounting Also uncertainty may be introduced by instability of the input frequency usually common with LC type oscillators Use of Antenna To measure transmitter frequency it is not always necessary to have adirect electrical connection to the transmitter In fact the counter should be protected against from excessive power levels A preferred method of frequency measurement is to connect an antenna to the input of the counter The BK Precision Model AT 21 Antenna Kit is ideal for use with the Model 1803D counter for measuring frequencies from 20MHz to 200MHz The antenna should be placed parallel with the transmitting antenna and separate by a few inches The specific distance is determined by the power level of the transmitter Some very low power transmitters may not provide enough signal to the counter with this this method An unmodulated carrier should be transmitted and the frequency will appear on the display of the counter Cable Considerations Cable connections in RF measurements should be aimed at reducing standing waves and shunt cable capacitance both of which can affect measurement accuracy Standing waves can be minimized by matching impedances of signal source cable and termination For example for a 50 ohm source use a 50 ohm cable and terminate with a 50 ohm resistive load Both standing waves and shunt cable capacitance can be reduced by keeping cable lengths sho
17. rt less than three feet 91cm Service Information Warranty Service Please return the product in the original packaging with proof of purchase to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Non Warranty Service Return the product in the original packaging to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Customers not on open account must include payment in the form of a money order or credit card For the most current repair charges please visit www bkprecision com and click on service repair Return all merchandise to B amp K Precision Corp with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact B amp K Precision Corp B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 10 Limited One Year Warranty B amp K Precision Corp warrants to the original purchaser that its products and the component parts thereof
18. will be free from defects in workmanship and materials for a period of one year from date of purchase B amp K Precision Corp will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To obtain warranty coverage in the U S A this product must be registered by completing a warranty registration form on www bkprecision com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed B amp K Precision Corp shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state B amp K Precision Corp 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 714 921 9095 14 TEST INSTRUMENT SAFETY continued from inside front cover 4 If possible familiarize yourself with the equipment being tested and the location of its high voltage points However remember that high voltage may appear at unexpected points in defective equ