Home

LM-3R Ethernet to DMX converter - SIRS-E

image

Contents

1. LM 3R Ethernet to DMX converter User Manual Manual de Usuario LM 3R Ethernet to DMX converter EN 0 SAFETY INFORMATION amp MAINTENANCE ENGLISH Read this manual before powering or installing the device follow the safety precautions listed below and observe all warnings in this manual e Be sure that the local power outlet matches that of the required voltage of the power supply included with this device e To reduce the risk of fire or electrical shock do not expose the unit to rain or high levels of moisture e Do not spill water or other liquids into or on your unit e Do not open the unit as there are no user serviceable parts inside e Do not dismantle or modify the unit as this voids all warranties e Do not attempt repairs Repairs by unqualified people could cause damage or faulty operation Contact your local authorized service center e Unplug this unit when not used for long periods of time e Clean only with dry cloth e Handle this unit carefully Any strong shock or vibration may result in malfunction SPANISH Lea este manual antes de encender o instalar el dispositivo siga las instrucciones de seguridad listadas a continuacion y observe las precauciones citadas en este manual e Aseg rese de que la toma de corriente local coincide con la tensi n necesaria de la fuente de alimentaci n incluida con el dispositivo e Para reducir el riesgo de incendios o descargas el ctricas no exponga la unidad a
2. Supply the unit with 5 V DC 500 mA through Plug in or Terminal Block 6 Now is possible to receive DMX information from the control console ACT LED will blink when LM 3R is transmitting or receiving data from the network 5 CONFIGURATION IN ART NET MODE 1 Select Art Net protocol using the dip number 1 ON position in the dip switch block at the rear panel 2 Select the Subnet using the dips 2 3 4 5 in the dip switch block at the rear panel up to 16 different positions This value must be the same as the Subnet value configured in the DMX console 3 Inthe group Universe selector at the front panel select one of the 16 positions 0 F corresponding to the DMX universe 4 Connect a standard RJ 45 cable between LAN connector and Ethernet network 5 Connect a DMX cable in the DMX OUT connector to feed with DMX signal a devices line 6 Supply the unit with 5 V DC 500 mA through Plug in or Terminal Block LM 3R User Manual WORK 6 LM 3R Ethernet to DMX converter EN 7 In this moment it is possible to receive DMX information from the control console ACT LED will blink when LM 3R is transmitting or receiving data from the network 6 CONNECTION EXAMPLES 5 LAN Z EHTHERNET SIDIUS 1200 SIDIUS 1200 WORKNET MODE Connection of a LM 3 system composed by a transmitter LM 3E and two receivers LM 3R all must be configured in the same group SIDIUS 1200 T H 5 GROUP 2 e 4 LAN LM 7 EHTHERNET too
3. and SubnetMask 255 0 0 Each LM 3R has a sticker at the bottom with its default settings Although LM 3R is plug and play it offers a user friendly web based management interface for the configuration of the network features To connect to the web interface you must set your PC IP address to be on the same subnet as the LM 3R that is the PC and LM 3R addresses must both start 2 x x x with subnet mask 255 0 0 0 Then to access the configuration menu use your web browser to connect to the management interface using the default IP addres shown in the sticker at the bottom of the device http 2 x x x LM 3R User Manual work i fy 3 LM 3R Ethernet to DMX converter EN The web interface allows to change the IP Address the Subnet Mask and the description of the device If the IP Address is modified it is very important to remember the new one in order to can connect the next time you access the web interface Anyway the EQDiscover utility can be used in order to obtain the network settings of the device All you have to do is connect the LM 3E to the LAN or to your computer and execute the application It will show in a window all the information about the network settings of the device EQDiscover utility can be downloaded from http www equipson es prodDetail asp idproducto 737 NETWORK SETTINGS a IF Seine 7 i e SianelYas 254 L Fig 1 The integrated WEB SERVER allows the SAVENEDVACRA SETTINGS configuration of the u
4. apagado y encendido de la misma con el fin de poder validar los nuevos datos 7 ESPECIFICACIONES e Alimentaci n 5 V DC 500 mA e Protocolos de red Art Net WORKNET protocolo propietario e Dimensiones 80 x 45 x 80 mm e Peso 3709 Este s mbolo en su equipo o embalaje indica que el presente producto no puede ser tratado como residuos dom sticos normales sino que deben entregarse en el correspondiente punto de recogida de equipos electr nicos y el ctricos Asegur ndose de que este producto es desechado correctamente Ud est ayudando a prevenir las consecuencias negativas para el medio ambiente y la salud humana que podr an derivarse de la incorrecta manipulaci n de este producto El reciclaje de materiales ayuda a conservar las reservas naturales Para recibir m s informaci n sobre el reciclaje de este producto conecte con su ayuntamiento su punto de recogida m s cercano o el distribuidor donde adquiri el producto LM 3R User Manual worki TY 14 LM 3R Ethernet to DMX converter ES WORK Y TECHNICAL SUPPORT Tel 34 961 216 301 E mail address support equipson es ENGLISH Technical Support information available at www equipson es SPANISH En www equipson es ud podr encontrar informaci n relativa a servicios de soporte t cnico INTERNET E mail address support equipson es World Wide Web http Awww equipson es LM 3R Ethernet to DMX converter LM 3R User Manual WORK W 15
5. be caused by inappropiate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product LM 3R User Manual work i fy 8 LM 3R Ethernet to DMX converter ES 1 DESCRIPCI N LM 3R es un convertidor Ethernet a DMX Ha sido dise ado para poder transportar DMX a trav s de una red Ethernet y tiene dos modos de funcionamiento WORKNET protocolo propietario y Art Net WORKNET MODE ART NET MODE e DMX gt DMX AA Anat DMX Eemer TES Art Net _ Emene E gt LM 3E LM 3R LM 3R LM 3R es un dispositivo plug and play y no necesita ninguna configuracion de red LM 3R se configura autom ticamente lo que significa que obtiene autom ticamente una direcci n IP 2 x x x y una M scara de Subred 255 0 0 0 tal y como especifica el protocolo Art Net Sin embargo para usuarios avanzados la configuraci n de red del dispositivo puede modificarse a trav s de un interfaz web como se explicar m s adelante 1 1 MODO WORKNET En modo WORKNET el LM 3R funciona como receptor de la informacion DMX enviada por el dispositivo LM 3E emisor Por lo tanto en este modo de funcionamiento el LM 3R siempre debe utilizarse en combinaci n con un LM 3E y ambos dispositivos deben configurarse en el mismo grupo o Universo DMX D
6. MX OUT para alimentar con se al DMX los dispositivos de la l nea 6 Alimente la unidad con 5 V DC 500 mA por cualquiera de las dos tomas destinadas a tal efecto Plug in o Terminal Block 7 En este momento es posible recibir la informaci n DMX enviada por la consola de control El LED ACT parpadear cuando la unidad transmita o reciba datos de la red Ethernet 6 EJEMPLOS DE CONEXIONADO FEHTHERNET SIDIUS 1200 SIDIUS 1200 MODO WORKNET Conexi n de un sistema LM 3 compuesto por un emisor LM 3E y dos receptores LM 3R todos ellos deben configurarse en el mismo grupo SIDIUS 1200 LAN EHTHERNET Multiuniverse DMA Console SIDIUS 575 SPOT MODO WORKNET Conexi n de un sistema LM 3 utilizando una consola DMX multiuniverso Es posible enviar dos universos diferentes a trav s de la red Ethernet utilizando dos emisores LM 3E y dos receptores LM 3R configurados en los mismos grupos tal y como se muestra en la figura LM 3R User Manual WORK W 13 LM 3R Ethernet to DMX converter GRUPO Subnet 10 LAN EHTHERNET DMX ArtNet Console MODO ART NET Usando una consola DMX Art Net transmitiendo la Subnet 10 con sus 16 universos con dos receptores LM 3R configurados en la Subnet 10 y en los universos que quieren recibir La asignaci n de Grupo Universo Protocolo y Subnet s lo se activar durante el proceso de inicio de la unidad Cualquier cambio en esta asignaci n requiere del
7. ci n IP 2 x x x y M scara de Subred 255 0 0 Cada LM 3R lleva una pegatina en su base con los valores de configuraci n por defecto Aunque LM 3R es plug and play el dispositivo dispone de un interfaz de administraci n web para la configuraci n de las propiedades de red Para conectar con dicho interfaz web debe configurar la direcci n IP de su PC de manera que pertenezca a la misma subred que el LM 3R esto es las direcciones IP de su PC y del LM 3R ambas deben comenzar por 2 x x x con m scara de subred 255 0 0 0 Una vez hecho LM 3R User Manual WORK 9 LM 3R Ethernet to DMX converter ES esto para acceder a la p gina web de configuraci n utilice un navegador web y conecte con la direcci n IP por defecto del dispositivo la cual aparece en una pegatina en la base del mismo http 2 x x x El interfaz web permite cambiar la direcci n IP la M scara de Subred y la descripci n del dispositivo Sila direcci n IP es modificada es muy importante recordar la nueva IP asignada de manera que pueda conectar con el dispositivo la siguiente vez que quiera acceder al interfaz web De cualquier modo la utilidad EQDiscover puede ser utilizada para obtener las propiedades de red del dispositivo Lo que tiene que hacer es conectar el LM 3R a la red LAN o a su PC y ejecutar la aplicaci n La aplicaci n mostrar en una ventana toda la informaci n sobre las propiedades de red del dispositivo La utilidad EQDiscover puede descargars
8. colo WORKNET utilizando el dip n mero 1 posici n OFF del bloque dip switch del panel trasero 2 En el selector de grupo UNIV del panel delantero seleccione una de las 16 posiciones Es necesario al menos un transmisor LM 3E configurado en el mismo grupo y conectado a la LAN 3 Conecte un cable est ndar RJ 45 entre el conector LAN y la red Ethernet 4 Conecte un cable DMX en el conector DMX OUT para alimentar con se al DMX los dispositivos de la l nea 5 Alimente la unidad con 5 V DC 500 mA por cualquiera de las dos tomas destinadas a tal efecto Plug in o Terminal Block 6 En este momento es posible recibir la informaci n DMX enviada por la consola de control El LED ACT parpadear cuando la unidad transmita o reciba datos de la red Ethernet 5 CONFIGURACI N EN MODO ART NET 1 Seleccione el protocolo Art Net utilizando el dip n mero 1 posici n ON del bloque dip switch del panel trasero 2 Seleccione la Subnet utilizando los dips 2 3 4 5 del bloque dip switch del panel trasero hasta 16 posiciones diferentes Este valor debe ser el mismo que el valor de Subnet configurado en la consola DMX 3 En el selector de grupo Universe en el panel delantero seleccione una de las 16 posiciones 0 F LM 3R User Manual WORK W 12 LM 3R Ethernet to DMX converter ES correspondiente al universo DMX 4 Conecte un cable est ndar RJ 45 entre el conector LAN y la red Ethernet 5 Conecte un cable DMX en el conector D
9. de LM 3R operates as the receiver of the DMX information sent by LM 3E the transmitter So in this mode LM 3R always must be used in combination with one LM 3E and both LM 3E and LM 3R must be configured in the same group or DMX universe In this way and generalizing to more than one receiver the DMX information sent by one LM 3E will be received for all the LM 3R configured in the same group as the LM 3E transmitter Note just one LM 3E can be associated to one or more LM 3R WORKNET is an own protocol that works in any standard TCP IP network The protocol is UNICAST in order to don t decrease network efficiency As seen before in this document and in LM 3E user manual both LM 3E and LM 3R are automatically configured and they don t need any network configuration They automaticallly obtain an IP address and a SubNet Mask so that they belong to the same subnet in order to can communicate each other 1 2 ART NET MODE In Art Net mode LM 3R operates as an Art Net node receiving all the information sent by an ArtNet compatible transmitter device In this case the group concept is replaced by universe uncluding Subnet concept just as Art Net protocol specifies As seen before LM 3R is automatically configured and it obtains an IP address and Subnet Mask just as Art Net protocol specifies 1 3 WEB SERVER LM 3R is a plug and play device By default it is automatically configured like an ArtNet device with an IP address 2 x x x
10. e de http www equipson es prodDetail asp idproducto 737 NETWORK SETTINGS IF iire ry 1 I e 5 nel Yas 254 L Fig l El WEB SERVER integrado permite la SAVEMEDIVORASE TINGS configuracion de la unidad 2 PANEL FRONTAL POWERR ACT LINK Jie ol E a 7 Ling DMX OL LM 3R User Manual WORK W 10 LM 3R Ethernet to DMX converter ES 1 LED POWER Este LED de color rojo se ilumina cuando la unidad dispone de alimentaci n 2 Alimentaci n Toma PLUG IN Mediante un alimentador de 5V DC 500 mA es posible alimentar la unidad Si se utiliza la toma PLUG IN para alimentar la unidad la toma Terminal Block no debe utilizarse 3 LEDACT Este LED verde parpadea cuando el puerto Ethernet est conectado y transmitiendo o recibiendo datos 4 LED LINK Este LED verde se enciende cuando el puerto Ethernet LAN est conectado a la red 5 Alimentaci n Toma Terminal Block Mediante un alimentador de 5V DC 500 mA es posible alimentar la unidad Si se utiliza la toma Terminal Block para alimentar la unidad la toma PLUG IN no debe utilizarse 6 Selector de Grupo Universo Bajo protocolo WORKNET Este selector permite seleccionar hasta 16 grupos de recepci n 0 F Cada grupo tendr su propio transmisor LM 3E configurado en el mismo grupo que sus receptores Bajo protocolo Art Net Este selector permite seleccionar uno de los 16 Universos DMX dentro de la Subnet configurada 7 DMX OUT Este con
11. e esta manera y generalizando para m s de un dispositivo receptor la informaci n enviada por un LM 3E ser recibida por todos aquellos LM 3R configurados en el mismo grupo que el LM 3E emisor Nota s lo un dispositivo LM 3E puede ser asociado a uno o m s dispositivos LM 3R WORKNET es un protocolo propietario que funciona sobre cualquier red est ndar TCP IP El protocolo es unicast con el objetivo de no disminuir la eficiencia de red Como se ha visto anteriormente en este documento y tambi n en el manual de usuario del LM 3E ambos dispositivos LM 3E y LM 3R se configuran autom ticamente y no necesitan ninguna configuraci n de red La direcci n IP y la mascara de subred es obtenida autom ticamente de manera que ambos dispositivos pertenezcan a la misma subred y puedan as comunicarse entre ellos 1 2 MODO ART NET En modo Art Net el LM 3R funciona como un nodo Art Net propiamente dicho recibiendo toda la informaci n enviada por un dispositivo emisor Art Net En este caso el concepto de grupo es sustituido por el de Universo incluyendo adem s el concepto de Subnet tal y como se especifica en el protocolo Art Net Como se ha dicho anteriormente LM 3R se configura autom ticamente obteniendo una direcci n IP y una m scara de subred tal y como especifica el protocolo Art Net 1 3 WEB SERVER LM 3R es un dispositivo plug and play Por defecto se configura autom ticamente como un dispositivo Art Net obteniendo una direc
12. ector XLR envia la senal DMX a una linea de control con dispositivos compatibles con DMX como cabezas moviles scanners drivers RGB etc 8 LAN Conector RJ 45 que permite la conexion del LM 3R a una red Ethernet 3 PANEL TRASERO WORKNET 9 Selector de modo de funcionamiento selector de Subnet Este dip switch tiene dos funciones o Permite seleccionar con el dip n mero 1 el modo de funcionamiento WORKNET posici n OFF o Art Net posici nON LM 3R User Manual WORKI 41 LM 3R Ethernet to DMX converter ES o nicamente en el modo de funcionamiento Art Net los dips n mero 2 3 4 5 permiten seleccionar la Subnet con valores de 0 a 15 16 posiciones Los n meros de color negro 1 2 4 8 indican el valor que toma el dip cuando est en posici n ON en posici n OFF el valor es 0 El valor de la Subnet resultante es la suma de los cuatro dips La siguiente tabla muestra la posici n en la que deben posicionarse los dips para cada valor de Subnet SUBNET VALUE Pin 2 Pin 3 Pin 4 Pin 5 valor 1 valor 2 valor 4 valor 8 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10 OFF ON OFF ON 11 ON ON OFF ON 12 OFF OFF ON ON 13 ON OFF ON ON 14 OFF ON ON ON 15 ON ON ON ON 4 CONFIGURACI N EN MODO WORKNET 1 Seleccione el proto
13. la lluvia o niveles altos de humedad e No derrame agua u otros l quidos al interior o dentro de la unidad e No abra la unidad ya que no hay piezas que el usuario pueda reparar e No desmonte ni modifique la unidad ya que anula todas las garant as e No intente reparaciones Las reparaciones efectuadas por personal no cualificado pueden causar da os o un funcionamiento defectuoso P ngase en contacto con su centro de servicio autorizado e Desenchufe la unidad cuando no se utilice por periodos prolongados de tiempo e Limpie s lo con un pa o seco e Transporte esta unidad con cuidado Cualquier golpe o vibraci n pueden provocar un mal funcionamiento LM 3R User Manual work i fy 2 LM 3R Ethernet to DMX converter EN 1 DESCRIPTION LM 3R is an Ethernet to DMX converter It has been designed to transport DMX through an Ethernet network and it has two operation modes WORKNET own protocol and Art Net WORKNET MODE ART NET MODE gt m DMX T ss DMX et Aut Niet DMX Ethemet oe Art Net stem ES LM 3E LM 3R LM 3R LM 3R is a plug and play device it does not need any network configuration LM 3R is automatically configured which means that it obtains automatically an IP address 2 x x x and a Subnet Mask 255 0 0 0 just as Art Net protocol specifies However for advanced users network configuration can be modified using the web browser interface as seen below in this document 1 1 WORKNET MODE In WORKNET mo
14. nit 2 FRONT PANEL a 2 Ling DMX OU 1 POWER LED This LED in red color will iluminate when there is power currently being supplied to the unit 2 Main Supply PLUG IN With an external 5V DC 500 mA power supply it is possible to supply the unit If you use PLUG IN connector to supply the unit don t use Terminal Block connector 3 ACT LED This green LED blinks when the Ethernet port is connected and is transmitting or receiving data LM 3R User Manual worki 7 4 LM 3R Ethernet to DMX converter EN 4 LINK LED This green LED is on when the Ethernet LAN port is connected to the network 5 Main Supply Terminal Block With an external 5V DC 500 mA power supply it is possible to supply the unit If you use Terminal Block connector to supply the unit don t use PLUG IN connector 6 Group Universe selector Under WORKNET protocol This selector allows to select one of the 16 reception groups 0 F Each group will have its own LM 3E transmitter configured in the same group Under Art Net protocol This selector allows to select one of the 16 DMX universes in the configured Subnet 7 DMX OUT This XLR connector sends the converted DMX signal to a control line with compatible DMX devices like moving heads scanners RGB drivers etc 8 LAN RJ 45 connector which allows the connection of LM 3R to Ethernet network 3 REAR PANEL 9 Operate mode Subnet switch This dip switch has two functions o It all
15. o LM3R 7 7 t me Multiuniverse OMX Console SIDIUS 575 SPOT WORKNET MODE Connection of a LM 3 system using a multiuniverse DMX console It is possible to send two different universes through the network with two transmitters LM 3E and two receivers LM 3R configured in the same groups as seen in figure LM 3R User Manual work i fy 7 LM 3R Ethernet to DMX converter 0 GRUPO Subnet 10 LAN j P gt EHTHERNET DMX ArtNet Console SIOIUS 575 SPOT ART NET MODE Using an Art Net DMX console transmitting Subnet 10 with its 16 universes with two receivers LM 3R configured in Subnet 10 and the universes they want to receive Group Universe assignation Protocol and Subnet will only be activated during the starting process Any change of this assignation needs to switch off the unit and switch on it again in order to validate the new data 7 SPECIFICATIONS e Main Supply 5 V DC 500 mA e Network protocols Art Net WORKNET own protocol e Dimensions 80 x 45 x 80 mm Weight 370 g This symbol on the product or in its packaging indicates that this product shall not be trated as household waste Instead it shall be handed over the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the enviroment and human health which could otherwise
16. ows to select with dip number 1 the operation mode WORKNET OFF position or Art Net ON position o Only in Art Net operation mode dips number 2 3 4 5 allow to select the Subnet with values from O to 15 16 positions The numbers in black color 1 2 4 8 indicate the value of the dip when is in ON position in OFF position the value is 0 So the resulting LM 3R User Manual WORK 5 LM 3R Ethernet to DMX converter EN SUBNET value is the sum of the four dips The table below shows the position of the dips for each Subnet value SUBNET VALUE Pin 2 Pin 3 Pin 4 Pin 5 value 1 value 2 value 4 value 8 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10 OFF ON OFF ON 11 ON ON OFF ON 12 OFF OFF ON ON 13 ON OFF ON ON 14 OFF ON ON ON 15 ON ON ON ON 4 CONFIGURATION IN WORKNET MODE 1 Select WORKNET protocol using the dip number 1 OFF position in the dip switch block at the rear panel 2 Inthe group selector UNIV at the front panel select one of the 16 positions It is necessary at least one LM 3E transmitter configured in the same group and connected to the LAN 3 Connect a standard RJ 45 cable between LAN connector and Ethernet network 4 Connect a DMX cable in the DMX OUT connector to feed with DMX signal a devices line 5