Home

CVW900 - KCS-900

image

Contents

1. 5 Coloque la tapa frontal de cierre en la posici n abierta como suministrada 6 Mientras gira el cable de un lado a otro en un medio giro un cuarto de vuelta en cada direcci n tire suavemente del cable hasta remover el terminal o SS J ES ZA EN wedge lock Para m s detalles acerca de los conectores consulte www te com
2. 1 4 mm 20 16 AWG Ferramenta de crimpagem recomendada TE 58529 1 A correta crimpagem dos terminais demonstrada abaixo Cilindro do fio deve ser fechado As extremidades na costura sem pontas salientes devem estar vis veis aparecendo As extremidades nesta rea do cilindro isolante devem envolver O isolamento do fio sem pontas que Fios e isolamento devem estar possam danificar a VIS VEIS veda o de borracha 0 25 mm m x 0 13 mm e do fio min entrada frontal o jo 0 13 0 75 mm E entrada traseira e 0 25 mm aba de corte m x 6 PROCEDIMENTO DE MONTAGEM Antes da montagem a tampa frontal de travamento do conector deve estar na posi o aberta conforme fornecido Contato inserido a j o fio parcialmente Danas da reten o N Sy Y al EEN o PE A AZ SPA PS A gt E NIDO Wedge lock Gaxeta mostrada na posic o aberta O conector deve ser montado conforme instru es abaixo 1 Para inserir um contato empurre o mesmo dentro de sua cavidade apropriada at o mesmo permitir 2 Puxe o cabo com uma for a de 4 45 a 8 9 N para assegurar se que as pincas de E est o segurando o terminal Diafragma Garras de reten o Puxar o fio mantendo contato para tr s 3 Ap s todos os contatos necess rios terem sido inseridos a tampa frontal de travamento deve ser fechada Trava de aperto para assentar wedge lock ambo
3. de este m dulo 1 2 RECOMENDACIONES PRELIMINARES A ATENCI N Siempre desconecte la alimentaci n general antes de conectar o desconectar los accesorios del convertidor de frecuencia CVW900 Espere al menos 10 minutos para garantizar la desenergizaci n completa del convertidor 2 INFORMACIONES GENERALES Este gu a orienta en la crimpado e instalaci n de los conectores de se ales de lo convertidor CVW900 3 CONTENIDO DEL EMBALAJE w 100 pzas Terminal TE 770520 1 asa Conector negro de 14 p v as TE 776273 1 Conector negro de 35 v as TE 776164 1 Conector gris de 35 v as TE 776164 4 gt tpza Gu ademontaj 4 FUNCIONES DE LOS TERMINALES DE LOS CONECTORES Para informaciones al respecto de las funciones de cada terminal consulte el manual del usuario del CVW900 5 INSTRUCCIONES PARA CRIMPADO DE LOS TERMINALES Recomendaciones del Di metro de los Cables Herramienta de Crimpado 0 5 1 4 mm 20 16 AWG Herramienta de crimpado recomendada TE 58529 1 El crimpado correcto de los cables es mostrado a continuaci n El cilindro del alambre debe ser cerrado en la costura sin puntas salientes Las extremidades del cilindro aislante deben envolver al aislamiento del alambre sin puntas que puedan da ar el sellado de goma del alambre 0 13 0 75 mm entrada trasera Las extremidades deben estar visibles en ke esta rea Los alambres y el aislamiento deben e
4. WEG Drives amp Controls Automa o LTDA Jaragu do Sul SC Brazil Phone 55 47 3276 4000 Fax 55 47 3276 4020 S o Paulo SP Brazil Phone 55 11 5053 2300 Fax 55 11 5052 4212 automacaoQweg net www weg net 13274086 Document 10003722062 00 1 INFORMA ES DE SEGURAN A 1 1 AVISOS DE SEGURAN A NOTA Recomenda se a leitura do manual do usu rio do CVW900 antes de instalar ou operar esse acess rio O conte do deste guia fornece informa es importantes para o correto entendimento e instala o desse acess rio 1 2 RECOMENDA ES PRELIMINARES ATEN O Sempre desconecte a alimenta o geral antes de conectar ou desconectar os acess rios do inversor de frequ ncia CVW900 Aguarde pelo menos 10 minutos para garantir a desenergiza o completa do inversor 2 INFORMA ES GERAIS Este guia orienta na crimpagem e instala o dos conectores de sinais do inversor CVW900 3 CONTE DO DA EMBALAGEM 4 100 pes Terminal TE 770520 1 4 Conector preto de 14 PE vias TE 776273 1 Conector preto de 35 vias TE 776164 1 Conector cinza de 35 vias TE 776164 4 DA tpe Guiade montagem 4 FUN ES DE CADA PINO DO CONECTOR Para informa es da fun o de cada pino de sinal dos conectores XC12 XC13 e XC14 consultar o Manual do Usu rio do CVW900 5 INSTRU ES DE CRIMPAGEM DOSTERMINAIS Recomenda es sobre Di metro dos Fios Ferramenta de Crimpagem
5. capacitors 2 GENERAL INFORMATION This guide provides directions for crimping and installation of the signal connectors for the inverter CVW900 3 CONTENT OF THE PACKAGE 100 pc TE 770520 1 terminal E MEN once A 1 pc pin connector TE 776164 1 black 35 pin connector TE 776164 4 gray 35 pin connector lo gt ipc Assembling guide 4 CONNECTORS PIN FUNCTION For any information about the pin functions please refer to the CVW900 user manual 5 TERMINALS CRIMPING INSTRUCTIONS Wire Sizes Crimping Tool Recommendations 51 mm a Recommended crimping tool TE 58529 1 The correct wire crimping is shown below Wire barrel shall be closed at seam with no strands protruding of showing Ends of insulation barrel must be wrapped around wire insulation leaving no sharp points to damage rubber wire seal 0 13 0 75 mm rear bellmouth 0 5 1 4 mm 20 16 AWG Wire strand ends must be visible in this area ke Wire strands and insulation shall both be visible 0 25 mm max 0 13 mm i min front bellmouth jo e 0 25 mm max cutoff tab 6 ASSEMBLY PROCEDURE Before assembling the wedge lock must be in the open or as shipped position Contact partially inserted Wire seal Retention fingers as YA a SSS o MEN CES 77 NS 2227 74 NJ Y Wedge lock shown Diaphragm a in open position Mating seal The plug must be assemb
6. led as it follows 1 Toinserta contact push it straight into the appropriate circuit cavity as far as it will go 2 Pull back into the contact wire with a force of 4 45 to 8 9 N to be sure of the ds fingers are holding the A a RAS NS Sy 2 k 3 After all required contacts have been inserted the wedge lock must be closed to its locked position Releasing the locking latches by squeezing them inward Squeeze locking latches to seat wedge lock both slides 4 Slide the wedge lock into the housing until it is flush with the housing ann Wedge lock flush SNY a 7 md with housing O N A RASS CESS 7 DISASSEMBLY PROCEDURE The plug must be disassembled contacts removed as it follows 1 Insert a 4 8 mm wide screwdriver blade between the mating seal and one of the red wedge lock tabs 2 Pry open the wedge lock to the open as shipped position 3 While rotating the wire back and forth over a half turn one quarter turn in each direction gently pull the wire until the contact is removed i vs i JE E 3 DE ZA De Wedge 4 lock tab For further details about the conectors please refer to www te com Espa ol 1 INFORMACIONES DE SEGURIDAD 1 1 AVISOS DE SEGURIDAD NOTA Se recomienda la lectura del manual del usuario del CVW900 antes de instalar u operar este accesorio El contenido de esta gu a se proporciona informaci n importante para el correcto entendimiento
7. s os lados 4 Aperte a tampa frontal de travamento em dire o ao conector at trav la Wedge lock nivelada com o corpo LAAMA OS 7 PROCEDIMENTO DE DESMONTAGEM O conector pode ser desmontado conforme demonstrado abaixo 1 Insira uma chave de fenda de 4 8 mm de largura entre o selo de veda o e as linguetas vermelhas de travamento 2 Coloque a tampa de travamento na posi o aberta conforme fornecido 3 Enquanto gira o cabo de um lado a outro em meiavolta um quarto de volta em cada dire o puxe tire suavemente o cabo at que o terminal qto removido Para maiores detalhes sobre os conectores consulte www te com Motors Automation Energy Transmission amp Distribution Coatings Signal Conectors Kit KCS 900 Kit de Conectores de Se al KCS 900 Kit de Conectores de Sinal KCS 900 Assenbling Guide Gu a de Montage Guia de Montagem gt D E AER al English 1 SAFETY INFORMATION 1 1 SAFETY WARNINGS NOTE Itis recommended to read the CVW900 user manual before installing or operating this accessory This guide contains important information regarding the proper understanding and correct operation of this module 1 2 PRELIMINARY RECOMMENDATIONS A ATTENTION m Always disconnect the general power supply before connecting or disconnecting the accessories of the CVW900 frequency inverter m Wait for at least ten minutes for the full discharge of the power
8. star visibles 0 25 mm max 0 13 mm j e min entrada frontal o po e 0 25 mm cota m xima de corte 6 PROCEDIMIENTO DE MONTAJE Antes del montaje la tapa frontal de cierre del conector debe estar en la posici n abierta conforme fue suministrada Contacto Sellado del insertado alambre cas do parcialmente a atenci n SSA zz AN 4 DO NESSES ZA as SEN d SE SS ma a ma Wedge lock Junta mostrada en la posici n abierta Diafragma hermetizante El conector debe ser montado como sigue 5 Para insertar un contacto emp jelo hacia dentro de su cavidad en l nea recta todo lo que pueda 6 Tire del cable con una fuerza de 4 45 a 8 9 N para asegurarse de que las pinzas de retenci n est n sujetando el contacto a sa Garras de Tirar del retenci n alambre manteniendo contacto hacia atr s a Despu s de que hayan sido insertados todos los contactos necesarios deber ser cerrada la tapa frontal de cierre Traba de apriete para asentar la wedge lock ambos lados 7 Apriete la tapa frontal de cierre en direcci n al conector hasta trabarla A Wedge lock ASAS nivelada con el OSOS AL cuerpo S SyS OS SS RSS 7 PROCEDIMIENTO DE DESMONTAJE El conector debe ser desmontado como a continuaci n 4 Inserte un destornillador de 4 8 mm de ancho entre la junta de estanqueidad y una de las pesta as de bloqueo de cu a de color rojo