FLEXpowerTM ONE

image

Contents

1. EE EE EE EM Derivaci n Tomacorriente e Ei 5 1 15 SUM STATUS SETUP ADV O FLEXmax En 23 2 V Salida 27 6 V 0 000 kW AUX fipag Qut Back Regulador Power Systems de carga de corriente continua del Inversor A f al Y gt UU M pessum S omomomomomomom mom OUR RR Y mE t OJFPLEXpower ONE IMPORTANTE Ejemplo solamente Cableado real puede variar Cableado de fabrica no se muestra Todas las configuraciones deben cumplir con los c digos el ctricos locales y nacionales Consulte a su autoridad local de electricidad para garantizar el cumplimiento Matriz Fotovoltaicos FV FLEXware PV8 Caja su conexiones o Leyenda CC Negativo b Positivo Banco de Bater as Y Cabina el banco de bater as con 24 o 48 Vcc ventilacion U m Cableado o S A E o lt Pagina 8 Acerca de OutBack Power Technologies OutBack Power Technologies es l der en tecnolog a avanzada de conversi n de energ a Nuestros productos incluyen inversores cargadores de onda sinusoida
2. Regulador de Carga FLEXmax 80 o FLEXmax 60 Sensor Remoto de Temperatura RTS Concentrador de Comunicaciones HUB4 o HUB10 Monitor FLEXnet CC Protector contra los sobrevoltaje transitorios Cortacircuito o un dispositivo para desconexi n gt gt gt gt gt gt gt gt gt Componentes suministrados por el cliente 5 gt Fuente de CA Sistema de Visualizaci n y Generador con un cortacircuito o un dispositivo para Control MATE2 desconexi n Fase de p els eun principal INVERTER ON OFF ae E u pane e ec FICO Entrada CA Mo s d 15 Banco de Bater as 24 o 48 Vcc e E Matriz Fotovoltaica FV con su caja de conexi nes Inversor _ Cargador Energ as Renovables Regulador de Carga FLEXmax 80 FLEXware PV8 o PV12 yatriz Fotovoltaicos erLEXrmax FV La energ a fotovoltaica Caja su Entrada CC 4 Entrada CC Subpanel el ctrico sue sano Fase de Salida CA Banco de Bater as CA Carga de las O bater as FV Cabina para el banco de bater as con Sa 24 o 48 Vcc ventilaci n salida del Inversor 900 0094 02 00 Rev A vsd Off Grid Overview02 de marzo de 2012 2012 OutBack Power Technology Todos los derechos reservados Pagi na 4 Qut Back Power Systems Ke 2 gt Q o O TE A O 8 a O t om n O O
3. Manualde Instrucciones del Monitor Er t qd FLEXnet CC FW250 DC 125 Interruptor diferencial 1 75 O 250 MEET egulador de Carga IIMPORTANTE Qut Back Matri Todas las configuraciones deben cumplir los c digos el ctricos locales y nacionales Consulte a su autoridad local i de electricidad para asegurar el cumplimiento Los requisitos pueden variar en el cableado Cableado de f brica no se muestra 900 0094 02 00 Rev A vsd Wiring info O2 de marzo de 2012 2012 OutBack Power Technologies Todos los derechos reservados Fotovoltaicos Pagina 1 Descripci n de usos Aplicaciones Panel de distribuci n principal Fase de Entrada CA Cargas Subpanel el ctrico Fase de in CA IMPORTANTE Ejemplo solamente Configuraci n real puede variar en funci n de las necesidades espec ficas de instalaci n 900 0094 02 00 Rev A vsd On Grid Overview 02 de marzo de 2012 2012 OutBack Power Technologies Todos los derechos reservados interconectadas a la red Concentrador de Monitor FLEXnet CC Comunicaciones HUB GE AAA OFLEX ware Control MATE2 Inversor Cargador Regulador de Carga FLEXmax 80 Qut Back Power Systems E ral Sistema de Visualizaci
4. or higher how Email Support outbackpower com Pec t shunt Shunt Yellow 11 51012 4Vde 23 0 to 24 8 Vdc 46 0 to 49 6 Vdc Website www outbackpower com omplet sorsan Connection Charge Controller Connection Charge Controller i i x 11 4 Vdc or lower 22 8 Vdcorlower 45 6 Vdc or lower See the MATE3 Operator s Back Cant inue Cont inue Rea 11 4 Vac or tower Manual for additional setup Inverter Status LED Indicators information ee Mizard Battery Monitor Mizard Battery Monitor Inverter on solid or standing by flash IMPORTANT JS shunt C i k AU E um Buda Bnet eo Yellow Yellow AC source in use solid or standing by flash source in use solid or standing by flash l pa nd for use zn ut 01 01 i ife support equipment 2012 OutBack Power Technologies All Rights Reserved Back Continue Cont inue Red Inverter error or warning see manual La SPP equ P member of The Group P 7 al Mounting WARNING Fire Explosion Hazard Do not place combustible or flammable materials within 12 feet 3 7 m of the equipment This unit employs mechanical relays and is not ignition protected Fumes or spills from flammable materials could be ignited by sparks WARNING Personal Injury Use safe lifting techniques and standard safety equipment when working with thi
5. rd Id SOT AC Conduit Box FW250 AC 120V NA z em zar em ieu an 07 ED ue Se iim ainia ERG CERT DC Conduit Box en Volta stem Voltage E m min Wattage 1000 Array Mattage 1000 ade Wattage 1000 ystem Display and Controller FW250 DC 125 Battery Tupe FL Capacity 500 h Battery Tupe FLA Capacity 500 fM Battery Type FLA Capacity 500 Ah B r us Ds FW250 DC 175 Back Cont inue Back Continue Back _ Continue FW250 DC 250 Mizard Battery Chargi Absorb Voltage 8 8 VDC Time Flaat Vol tage 27 2 VOC Equlize Voltage 30 0 VDC Mizard Battery Charging Absorb Voltage 26 6 VDC Tire Float Voltage 27 2 VOC Equlize Voltage 30 0 VOC Re Fioat Voltage 22 0 VOC Wizard Battery Charging Absorb Voltage 26 8 VDC Time System Display and MATE2 Controller MATE3 1 0 Filowt Voltage 27 2 VOC Time 4 0 Equlize Voltage 30 0 WDC Time 3 0 Re Float Voltage 72 0 WDC Back _ Continue Re Float Voltage 22 0 WDC Back Cont inue _ Continue Charge Controller FLEXmax 60 FLEXmax 80 Hizard AC Configuration AC Voltage 170 VAC AC Phase Single AC Input Breaker Size 604 H x min Output Load AA Back Continue Mizard AC Configuration AC Output Voltage 120 VAE AC Phase Single AC Input Breaker Size Hagimum Output Load Back Continue Mizard AC Configuration AC Output Voltage 120 VAC Phase Single Input Breaker Size 60 A
6. Haximum Load Back Charge Controller Communications FLEXmax 80 Manager Continue Remote Temp Sensor RTS Wizard Generator Conf igurat Wizard Generator Configura Wizard Generator Configuration Generator Installed Generator Installed H Generator Installed FLEXnet DC Monitor FNDC Go tor Tu Size 5 0 Generator Type Size 5 0 ku erator Type zb 5 0 z Generator Start fanual Generator Start Hormel Generator Start T Q Inverter Surge Protector FW SP ACA AUX Output Device Port 1 AUX Output Device Port 1 AUX Output Device Port 1 ya J Cha rger Back Cont inue Back Continue d Back Continue ze l Customer Supplied Com ponents PO i N 20 M 5 Wizard Grid Use Schedule Wizard Grid Use Schedule 59 AC Source Utility Grid or Period 1 Enable N Period Enable ale AC Generator Heehday Use 0 00 Drop 0 00 Meckday Use 0 00 Drop 0 00 i Weekend Use 0 00 Drop 0 00 Weekend Use 0 00 Drop 0 00 E Back Continue Back Continue Main Electrical Panel If FNDC is installed or overcurrent device for AC source Hizard Battery Monitor Wizard Grid Use Schedule Wizard Grid Use Schedule 5 Period 2 Enable Period Z Enabl finn Inverter Weekday Use 0 00 Drop 0 00 ds Drop 0 00 Electrical Distribution Subpanel Load Panel Back Continue Back Continue Continue Hizard Grid Use Schedule Wizard Grid Use Schedule Battery Bank Period 3 Ena
7. Conductor _ gm E AL DC LEGEND AC Subpanel Negative Ground 2 Loads 120 Vac Battery Bank TIT Td Power Systems PV Circuit Breaker oe 900 0132 01 00 Rev A vsd Page 4 2013 01 17 Connects to the terminal on the circuit breaker 2012 OutBack Power Technologies All Rights Reserved that is opposite the inverter DC cable Vented Battery Enclosure
8. D i OFLEXmax 0 Positivo i TEE 2 Tierra Varilla a Tierra i i I B Subpanel el ctrico qf i I E i i I H I 4 i i i N I 1 L y e Y i PAAK o i o Hi Cargas 30A ii Cortacircuitos L se 230 Vca m xima AN i estado de I I I I Tierra i las baterias E RUE yl OOOOO TF I Es i 255 I I Cabina para pubem Power Systems de aterias con p i i i i 24 o 48 Vcc ventilaci n 4 i i vada y AA 4 J i A El cable se une al terminal del I 900 0094 02 00 Rev A vsd On Grid WiringVO2 de marzo de 2012 cortacircuitos que es frente al cable i 2012 OutBack Power Technologies Todos los derechos reservados de corriente continua del Inversor X Y Pag Ina 5 _ EEEE Cableado general Aplicaciones interconectadas a la red O IFLEX power ONE Leyenda CA a mme H e d IMPORTANTE Ejemplo solamente N P E Cableado real puede variar Cableado de f brica no se muestra Neutro PA E t rica Todas las configuraciones deben cumplir con los c digos el ctricos locales y nacionales t a Consulte a su autoridad local de electricidad para garantizar el cumplimiento Fase de CA L1 EN ENS NN D Tierra Panel de distribuci n principal 230 Vca Entrada Salida
9. n de licencias y capacitaci n para la instalaci n de sistemas de energ a i el ctrica con tensi n alterna y continua hasta 240 Vca y 150 Vcc i gt Consulte con el Manual de Instalaci n del FLEXpower ONE para obtener informaci n detallada sobre los procedimientos de seguridad e instalaci n 900 0094 02 00 Rev A vsd TOC 02 de marzo de 2012 2012 OutBack Power Technologies Todos los derechos reservados OJIFLEXpoweronte Solo para los modelos Tama o del cable de CA y los de 240V requisitos de par de torsi n Tama o del cable Par de torsion 14 10 2 3 20 2 8 25 35 35 40 50 50 Concentrador de Comunicaciones HUB Componentes Principales Vista lateral Productos de OutBack Power Technologies gt Inversor Cargador VFX o GTVFX modelos FW250 AC 230V EU FW250 DC 125 FW250 DC 175 o FW250 AC 230V Sistema de Visualizaci n y Control EU MATE2 o MATE3 Regulador de Carga FLEXmax 80 o FLEXmax 60 Sensor Remoto de Temperatura RTS gt Concentrador de Comunicaciones Interruptores de del sistema c A C O c 19 O o i O e Enclavamiento Mec nico Derivaci n Se recomienda que los conductores de cobre THHN 16 25 o m s valorados a 75 C m nima menos c digo local requiera lo contrario Protector contra los sobrevoltajes transitorios en el
10. A vsd Page 3 2013 01 17 2012 OutBack Power Technologies All Rights Reserved General Wiring O FLEXpower ONE EA IMPORTANT Example only AC Distribution Actual wiring may vary Factory wiring not shown All configurations must comply with local and national electric codes Panel Consult your local electric authority to ensure compliance or disconnect device E ep e 140 nie dps D OM a ld a Vcc MEME L1 L2 i rer ee ORE Bypass ee ee ee NEUTRAL Outlet 60 A Circuit AC LEGEND Breaker 3 Maximum AS i S permea ed If the FLEXnet DC battery monitor is not installed the DC shunt will not be installed GROUN Neutral M HOTL1 VETE INVERTER ON OFF S 2 E INVERTER gt ON OFF p gt E AUX El o En gt z z AUX a ie o 9 s If the DC shunt is not installed connect the DC negative cable Cusack directly to the DC negative terminal on the inverter Ground DC Negative Terminal on the Inverter DC Negative Cable OFLEX max eo M P D Ground Electrode
11. 1 792 9651 Fax 1 561 792 7157 European Office Hansastrasse 8 D 91126 Schwabach Germany Phone 49 9122 79889 0 Fax 49 9122 79889 21 12 12 Cut Back POWER member of The alpha Group OJFLEX power ONE Descripcion general del sistema Contenido Descripci n general del sistema Tama o del cable y los requisitos de par de torsi n 1 Descripci n de usos Aplicaciones interconectadas la red 2 Aplicaciones interconectadas a la red interactiva 5 Aplicaciones aisladas desconectadas de la 4 Cableado general Aplicaciones interconectadas a la red con un Monitor FLEXnet 5 Aplicaciones interconectadas la red 6 Aplicaciones Aplicaciones aisladas desconectadas de la red Conan Monitor REX GC scarico laca 7 Aplicaciones aisladas desconectadas de la 8 mT ADVERTENCIA Riesgo de descarga el ctrica 5 Esta informaci n debe de utilizado por personal calificado y que se re na todos los requisitos de los c digos locales y gubernamentales para la concesi
12. Cableado Matriz de Fotovoltaicos Y FV a 7 Neutro Derivaci n Entrada 4 Tomacorriente pum amp a o Lo jmd Q im ES CA 4 1 I 7 ECAN i w j L i m ME FLEXware PV8 m xima i A E Caja su conexiones 1O 11 lo aye 2 ME s T ite Qe E i i T i Tierra del sistema primario Leyenda Conductor del electrodo de tierra I i i i O Negativo 1 T 1 1 I am fmm i i me x A i EM EE T i Tierra Varilla a Tierra PA e Subpanel el ctrico i 6 E B I B i i il nsum q ETE 1 Banco de Baterias r AUX Apag 1 Ball E eq mu i il i Cargas i n 230 Vca RTS i I T P I 4 E I 1 AA A d ag n ptum Cabina para a e 1 EU il 4 tacircuit T bater as con N i 5 i E 24 o 48 Vcc ventilaci n A am um mm El cable se une al terminal del i cortacircuitos que es frente al Cable de corriente continua del Inversor 900 0094 02 00 Rev A vsd On
13. D A y Ke IMPORTANTE Ejemplo solamente Configuraci n real puede variar en funci n de las necesidades espec ficas de instalaci n o Cableado general Aplicaciones interconectadas a la red con un Monito OJFLEXpowerornte E IMPORTANTE Ejemplo solamente Cableado real puede variar Cableado de f brica no se muestra Todas las configuraciones deben cumplir con los c digos el ctricos locales y nacionales Consulte a su autoridad local de electricidad para garantizar el cumplimiento Leyenda CA v v Hed PA m El ctrica AN Panel de distribuci n L1 principal 230 Vca 5550956 A O Entrada Fase de CA pue amp TE HE Te G o O c O ru E Salida Matriz Fotovoltaicos 1 FV Entrada CA e um mm umm a I EB 7 i l L I T i t i l FLEXware PV8 20 A 1 pcm E Cortacircuitos i EMO Caja su conexiones I E m xima P i x 2 ols TEE i mon 08 a 1 Tierra T CP 2229099068 i y J i lt Leyenda CC Tierra del sistema primario i T Conductor del electrodo de tierra i i Negativo 1 I I
14. FLEXpower Sistema de inversor nico completamente pre cableado e Sistema completamente pre cableado Instalaci n r pida e Configuraci n r pida facil e Optimizado para espacios peque os e Amplias provisiones para el interruptor de CA y CC Probado en f brica El nuevo FLEXpower ONE System contiene todos los dispositivos de protecci n esenciales en el espacio m s peque o posible al m s bajo costo de instalaci n por lo que es ideal para aplicaciones con requerimientos de energ a moderados tales como caba as chalets casas reas de comunicaciones remotas y sistemas de energ a de respaldo Con un dise o extremadamente compacto y un soporte de montaje f cil de instalar el sistema FLEXpowerONE completamente pre cableado y probado en f brica ha sido dise ado para una r pida instalaci n ahorrando tiempo y dinero FLEXpowerONE incluye un nico inversor cajas de cableado de CA y CC un nico controlador de carga FLEXmax MATE HUB FLEXnetDC y protector contra sobretensiones y a la vez mantiene un tama o compacto El FlexpowerONE System tambi n est equipado con interruptores de bater a y fase PV un interruptor PV GFDI un ensamble de entrada salida bypass ubicaciones de montaje para las salidas estilo CA GFCI tipo B y EU tipo F e interruptores de CA adicionales Los componentes de FLEXpowerONE incluyen todas las certificaciones ETL necesarias y permiten una instalaci n confor
15. Grid Wiring No FNDC 02 de marzo de 2012 2012 OutBack Power Technologies Todos los derechos reservados Pagina 6 _ eV Cableado general Aplicaciones aisladas desconectadas de la red con un Mo Generador de CA 230 V Neutro B 5 e Fase de CA L1 Derivaci n Tomacorriente Tierra Fase terminales del y p Neutro generador A Algunos generadores pueden tener un cortacircuitos que es integrado o tener un dispositivo para la desconexi n Si no hay que proporcionar EET E NI AW aNH 3LYW dWal Tierra del sistema primario Conductor del electrodo de tierra E OFLEXmax Varilla a Tierra bua na Subpanel el ctrico Cargas 230 Vca estado de las baterias erra a Ciut Back Regulador Power Systems de carga FV cortacircuitos 900 0094 02 00 Rev A vsd off grid wiringVO2 de marzo de 2012 2012 OutBack Power Technologies Todos los derechos reservados EI cable se une al terminal del cortacircuitos que es frente al Cable de corriente continua del Inversor OIFLEXpower ONE IMPORTANTE Ejemplo solamente Cableado real puede variar Cableado de f brica no se muestra Todas las configuraciones deben cumplir con los c digos el ctricos locales y nacionales Consulte a su autoridad local de electricidad para garantizar el cu
16. Secure the mounting Y plate to the wall at the three id es AC Conduit Box Side View Mechanical Interlock Bypass Es E AC e mms e Terminals GFCI Outlet Control Wiring Terminals Battery Terminals Circuit Breaker Stud Battery Bank Battery Status D C Monitor T erminals Charge Controller _ _ _ DC Conduit Box Battery Cable Connections with the FNDC Bolt M8 x 1 25 Flat Washer Sy mab Lock Washer C Charge Controller gt coso Battery Lug Inverter Battery Lug must install upside down on units with both Shunt A and Turbo Kit OJFPLEXpower ONE AC Wire Sizes and Torque Values It is recommended that conductors be 6 AWG THHN copper or larger rated to 75 C minimum unless local code requires otherwise Control Wiring Terminal Block The Inverter ON OFF terminals are used for connecting an external ON OFF switch To use this feature the jumper must be removed See installation manual for details The AUX terminals provide a 12 Vdc signal The AUX terminals can be used to start a generator or to control external devices AUX terminals are also available in the charge controller and FLEXnet DC See the charge controller or FNDC manuals for details Torque requirements for the conductor lugs Minimum DC C
17. able based on the DC Circuit Breaker Torque Circuit Cable Size Breaker Inib Nm 10 70 mr A CAUTION Equipment Damage When connecting cables from the inverter to the battery terminals ensure the proper polarity is observed Connecting the cables incorrectly can damage or destroy the equipment and void the product warranty Battery Cable Connections without the FNDC K Nut IT T Lock Washer s Protector gt dn c per lt Cable Lu g Nu MM Flat Washer Lock Washer Charge Controller Ne attery Lug Bolt M8 x 1 25 Mounting Surface E Isolator Inverter Battery Terminal Post Energize Startup De Procedures OJIFLEXpowerornte Pre startup Procedures Side View 1 Double check all wiring connections Side View 2 Inspect the enclosure to ensure no tools or debris has been left inside 3 Disconnect all AC loads at the backup or critical load panel Review the system configuration to identify all possible 4 Disconnect the AC input feed to the FLEXpower ONE at the source sources of energy Ensure ALL sources of power are AC Conduit Box AC Conduit Box To energize or start up the OutBack devices disconnected before performing any installation Or 1 Usi digital voltmeter DVM verify 12 24 or 48 Vdc on the DC input en sing a digital voltme verify 12 24 terminals by placing the DVM leads on and b Confirm that th
18. ble MW Period 4 Enable Weekday lise 0 00 Drop 0 00 Heekday Use 0 00 Drop 0 00 Photovoltaic PV Array with PV Combiner Box PV8 or PV12 Mizard Battery Monitor Shunt B Connection Charge Control ler Continue Back Continue Continue Qut Back d FNDC LED Indicators Battery State of Charge 9096 blinks if charge parameters are met Hizard Battery Honitor Shunt C Connection Disabled Mizard High Battery Transfer Hode Disabled Grid Connect 12 0 Delay 60 Hin Grid Disconnect 13 0 VOC Delay 60 Hin Grid Connect SOC 60 Disconnect SOC 5 Mizard High Battery Transfer Hode Disabled Grid Connect 12 0 VDC Delay Hin Grid Discompect 13 0 VOC Delay Hin Grid Connect SUC 60 Disconnect SUL 95 _ _ _ Back Continue Back Continue v Yellow 270 i ellow 2 7096 NE T UADIT ere O Yelow Mizard Battery Monitor Wizard Battery Monitor Tem H 2 6096 96 i 96 bli LEGEND ide A Seidel LED Indicators on the Inverter II Conmection Inverter Cannection Inverter Active Retums to the Main Menu Back PE dva Battery Status LED Indicators Su Contact Technical Support E Returns to the Configuration 12 V Inverter 24 V Inverter 48 V Inverter Telephone 1 360 618 4363 Wizard menu a Yellow at Wizard Battery Monitor Wizard Battery Monitor 12 5 Vdc or higher 25 0 Vdc or higher 50 0
19. e CA y CC con desv o de 230 VCA enchufe europeo interruptor de 250 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones GVFX3048E 3 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 230 VCA enchufe europeo interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUBA RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones 98 Ibs 44 5 kg 109 Ibs 49 4 kg 12 88 x 19 69 x 33 44 32 72 x 50 01 x 84 94 cm 17 x 22 75 x 38 43 18 x 57 79 x 96 52 cm Especificaciones sujetas a cambios sin previo aviso Los componentes individuales de FLEXpowerONE incluyen todas las certificaciones ETL necesarias Cut Back POWER member of The ahim Group Corporate Office 5917 195th St NE Arlington WA 98223 USA Phone 1 360 435 6030 Fax 1 360 435 6019 www outbackpower com Se monta cilmente CONCONDONALARED D sobre el soporte a E El sistema FLEXpowerONE fue dise ado con la idea de que sea f cil de instalar El soporte colgante se puede instalar r pidamente y as permite colgar todo el sistema con un m nimo esfuerzo A 1 E SD i PF Disponible en Asia Office Suite 1903 Tower 1 China Hong Kong City 33 Canton Road Kowloon Hong Kong Phone 852 2736 8663 Fax 852 2199 7988 Latin American Office 15105 Cedar Bluff Pl Wellington FL 33414 USA Phone 1 56
20. e amm Pr dota oat mala voltage is correct for the inverter and charge controller models Confirm rated for 1000 Vac and 1000 Vac to verify Mechanical the polarity Mechanical the de energized condition Interlock Interlock a Hof N CAUTION Equipment Damage E ee 7 e E Incorrect battery polarity will damage the equipment 2 Turnon close the GFDI circuit breaker 1 Verify the voltage on the PV terminal is in the correct range of open circuit voltage by placing the DVM leads on and 25 Confirm the polarity Turn on close the PV input circuit breakers 2 Turn on close the DC circuit breaker from the battery bank to the inverter 3 WARNING Lethal Voltage WARNING Lethal Voltage The numbered steps will remove power from the inverter and charge controller However sources of energy may still be present inside the GSLC and other locations To ensure absolute safety disconnect ALL power connections at the source WARNING Burn Hazard Internal parts can become hot during operation Do not remove the cover during operation or touch any internal parts Be sure to allow them sufficient time to cool down before attempting to perform any maintenance Verify 120 Vac on the AC output circuit breakers by placing the DVM leads on G and 82 Turn on close the AC output circuit breakers 4 Connect the AC source Verify 120 Vac on the AC input circuit breakers by placin
21. g the DVM leads on and 9 Turn on close the AC input circuit breakers 10 Turn on the AC disconnects at the load panel and test the loads de energize or shut down the OutBack devices 1 Turn off open the AC circuit breakers Turn off open the DC circuit breaker for the battery 2 Turn off open the PV circuit breaker 3 Turn off open the GFDI circuit breaker 4 Functional Test Points Battery Voltage Test Points Battery Negative Terminal on the Inverter xe o Verify 0 Vdc on the DC input terminals of the inverter by placing the voltmeter leads on and Verify O on the PV terminal by placing the voltmeter leads on and 7 Verify O Vac on the AC output circuit breakers by placing the voltmeter leads on G and 82 Circuit Breaker Terminal connected to the Battery NS M Positive Cable wu ES a E EN f Circuit Breaker Terminal a connected to the Inverter mz 1 H nooo E DC Positive Cable j PV Voltage Test Points PV Negative Terminal on the Charge Controller Circuit Breaker terminal for the PV PV Positive Terminal on the Charge Controller See the Functional Test Points key that is included with the Startup Procedures AC OUT Voltage Test Points G 62 DC Conduit Box DC Conduit Box AC IN Voltage Test Points 900 0132 01 00 Rev
22. interior Sistema de Visualizaci n y Control MATE2 Solo para los o HUB10 gt Monitor FLEXnet CC Protector contra los sobrevoltaje transitorios Componentes suministrados por el cliente gt Fuente de CA Red el ctrica o Generador con un cortacircuito o un dispositivo para desconexi n Panel de distribuci n principal Subpanel el ctrico Banco de las Bater as 24 o 48 Vcc Matriz Fotovoltaica FV con su caja de conexi nes YYY WV Documentacion de referencia gt Manual de Instalacion del FLEXpower ONE gt Manual de Instalacion del Inversor Cargador Serie FX NI NET NETA NI LOH 3Y XCT E DADOSO Inversor Cargador Regulador de Carga FLEXmax 80 OIFLEXmax modelos de 120V C Compartimiento de terminales de CA Terminales de CC Par de datos para zapatas del interruptor Par de torsion Interruptor de estudios EI Conductor m nimo de CC se bas en el Cach n de CC Tama o del Par de torsion Tornillos cable Nm db Manual del Usuario del Inversor Cargador Serie FX 250 120 4 0 254 225 Manual del Usuario de la Serie MATE o MATE3 o __ Manual de Instrucciones del Concentrador E aes IMPORTANTE No est MMA E dise ado uso medico
23. l pura reguladores de carga con seguidor del punto de m xima potencia componentes de comunicaci n de sistemas as como paneles de interruptores interruptores batter as accesorios y sistemas montados Informaci n de contacto Tel fono 1 360 435 6030 Principal 1 360 618 4363 Asistencia t cnica 1 360 435 6019 Fax Direcci n OutBack Power Technologies Ventas marketing y garant a 5917 195 Street N E 6115 192nd Street Arlington WA 98223 Estados Unidos Arlington WA 98223 Estados Unidos E mail SupportOoutbackpower com Sitio web www outbackpower com Exenci n de responsabilidad A MENOS QUE SE ACUERDE ESPEC FICAMENTE POR ESCRITO OUTBACK POWER TECHNOLOGIES a NO OFRECE NINGUNA GARANT A REFERENTE A LA PRECISI N SUFICIENCIA O ADECUACI N DE NING N TIPO DE INFORMACI N T CNICA O DE OTRO TIPO CONTENIDA EN SUS MANUALES O EN CUALQUIER OTRA DOCUMENTACI N NO SE HACE RESPONSABLE DE P RDIDAS O DA OS YA SEAN DIRECTOS INDIRECTOS DERIVADOS O ACCIDENTALES QUE SE PUEDAN DERIVAR DEL USO DE DICHA INFORMACI N EL USUARIO ASUME TODOS LOS RIESGOS DERIVADOS DEL USO DE DICHA INFORMACI N Resumen de la garant a OutBack Power Technologies garantiza que los productos que fabrica no tendr n defectos de material ni de fabricaci n en un periodo de cinco 5 a os sujetos a las condiciones establecidas en los detalles de la garant a que puede encontrar en la parte posterior de este manual Ou
24. lida tipo B interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUBA RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones GTFX3048 3 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y salida tipo B interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 y protector contra sobretensione FLEXnetDC no incluida FX3048T 3 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y salida tipo B interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones FX2524T 2 5 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y salida tipo B interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones VFX3024E 3 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 230 VCA y salida tipo F interruptor de 250 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones VFX3048E 3 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 230 VCA y salida tipo F interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones GVFX3024E 3 kW FLEXpower ONE cajas pre cableadas d
25. me al c digo que ahorra tiempo y dinero y a la vez conserva una buena imagen FLEXpowerONE System de OutBack Power es la nica opci n cuando necesita un sistema de energ a totalmente integrado de Out Back POWER member of The alil Group www outbackpower com onda sinusoidal pura y confiable Especificaciones de FLEXpower ONE Para aplicaciones de 120 V 60 Hz Sistemas pre cableados FP1 1 FP1 2 FP1 3 FP1 4 FP1 25 FP1 26 FP1 27 Para aplicaciones de 230 V 50 Hz FP1 5 FP1 6 FP1 34 FP1 35 Peso Unidad Env o Dimensiones Unidad Alto xXAnchoxLargo Env o Descripci n VFX3524 3 5 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y salida tipo B interruptor de 250 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUB4 RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones VFX3648 3 6 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y salida tipo B interruptor de 175 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUBA RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones GVFX3524 3 5 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y salida tipo B interruptor de 250 ACC GFDI interruptor del controlador de carga de 80 A MATE2 HUBA RTS FLEXmax 80 FLEXnetDC y protector contra sobretensiones GVFX3648 3 6 kW FLEXpower ONE cajas pre cableadas de CA y CC con desv o de 120 VCA y sa
26. mplimiento atriz Fotovoltaicos ance my EV m FLEXware PV8 Caja su conexiones Cableado Aplicaciones aisladas con un Monitor FLEXnet CC Leyenda CC Negativo Positivo lerra Banco de Bater as Cabina para el banco de bater as con 24 o 48 Vcc ventilaci n Pagina 7 Generador de CA 230 V Fase Terminales del y deca neutro L1 generador A Algunos generadores pueden tener un cortacircuitos que es integrado o tener un dispositivo para la desconexi n Si no hay que proporcionar Tierra del sistema primario Conductor del electrodo de tierra mm uu RE m um 7 um um Varilla a Tierra Subpanel el ctrico PEER Cargas 230 Vca Cj Cj Tierra V m m m m m m m m m m m m m m m m 900 0094 02 00 Rev A vsd Off Grid Wiring No FNDC 02 de marzo de 2012 2012 OutBack Power Technologies Todos los derechos reservados mmmmmmmmmmmmmmm A Neutro AON Entrada Salida Aca Ld FV cortacircuitos e El cable se une al terminal del cortacircuitos que es frente al Cable
27. o por las cargas de CA Las cargas tienen prioridad sobre la venta a la red Opcional Un generador con un interruptor o dispositivo de sobrecorriente se puede utilizar en esta aplicaci n para realizar copias de seguridad Sin embargo un tipo espec fico de generador no es necesario Ver la literatura inversor para obtener m s detalles Subpanel el ctrico Fase de Salida CA de la red p blica por defecto SI ER est disponible se pone primera prioridad en este caso El resto se vende Ver nota 1 po Tee e mam ma a e a a a a Q IMPORTANTE Ejemplo solamente Configuraci n real puede variar en funci n de las necesidades espec ficas de instalaci n 900 0094 02 00 Rev A vsd Grid Tie Overview 02 de marzo de 2012 2012 OutBack Power Technology Todos los derechos reservados interconectadas a LE EO p as I Concentrador de Comunicaciones HUB Monitor FLEXnet CC 12 A SS JAMAS ware Sistema de Visualizaci n y Control MATE2 dW3l VEI E La 3 02 14P SUM STATUS SETUP ADV j Inversor Cargador Regulador de Carga FLEXmax 80 OJFLEXK max sous ngo Qut Back Power Systems a Co La energ a fotovoltaica Entrada CC OFLEXpowerorntce C
28. omponentes Principales Productos de OutBack Power Technologies Inversores Cargadores GVFX o GTVFX modelos FW250 AC 230V EU FW250 DC 125 FW250 DC 175 o FW250 DC 250 Sistema de Visualizaci n y Control MATE2 o MATE3 Regulador de Carga FLEXmax 80 o FLEXmax 60 Sensor Remoto de Temperatura RTS Concentrador de Comunicaciones HUB4 o HUB10 Monitor FLEXnet CC Protector contra los sobrevoltaje transitorios mponentes suministrados por el cliente Fuente de CA Redel ctrica Panel de distribuci n principal Subpanel el ctrico Banco de Bater as 24 o 48 Vcc Matriz Fotovoltaica FV con su caja de conexi nes Energ as Renovables ER FLEXware Matriz Fotovoltaicos PV8 o PV12 Caja su conexiones Entrada CC O FLEX ware 0 o 5 Sc Oo 5 25 a o Banco de Bater as CA Carga de las bater as FV Cabina para el banco de bater as con Salida CC 24 o 48 Vcc ventilaci n salida del inversor Pagina 3 2 pu Q pum E Descripci n de usos Aplicaciones aisladas desconectadas de la red OFLEeXpowerornte Componentes Principales Concentrador de Productos de OutBack Power Technologies Comunicaciones HUB Monitor FLEXnet CC Inversores Cargadores FX o VFX modelos FW250 AC 230V EU FW250 DC 125 FW250 DC 175 FW250 DC 250 Generador Sistema de Visualizaci n y Control MATE2
29. on y OJFPLEXpower ONE Componentes Principales Productos de OutBack Power Technologies Inversores Cargadores VFX o GT VFX modelos FW250 AC 230V EU FW250 DC 125 FW250 DC 175 o FW250 DC 250 Sistema de Visualizaci n y Control MATE2 o MATE3 Regulador de Carga FLEXmax 80 o FLEXmax 60 Sensor Remoto de Temperatura RTS Concentrador de Comunicaciones HUB4 o HUB10 Monitor FLEXnet CC Protector contra los sobrevoltaje transitorios gt gt gt gt gt gt gt gt gt Componentes suministrados por el cliente gt Fuente de CA Red el ctrica o Generador con un cortacircuito o un dispositivo para desconexi n Panel de distribuci n principal Subpanel el ctrico Banco de Bater as 24 o 48 Vcc Matriz Fotovoltaica FV con su caja de conexiones Energ as Renovables FLEXware PV8 o PV12 La energ a fotovoltaica e conexiones Entrada CC Entrada CC _ Banco de Bater as Carga de CA las O bater as 3 Cabina para el banco de Salida ge 221198 inversor Pagina 2 O 0 5 9 O o O Matriz Fotovoltaica FV pus S o 1 Lo E Q eb c Descripci n de usos Aplicaciones Panel de distribuci n principal Fase de Entrada CA Fase de Salida 1 Un exceso de energ a renovable no est siendo utilizad
30. s equipment IMPORTANT Clearance and access requirements may vary by location Maintaining a 36 91 4 cm clear space in front of the system for access is recommended Consult local electric code to confirm clearance and access requirements for the specific location FP1 Dimensions 33 5 85 cm tall X 19 75 50 cm wide To install the mounting bracket 1 Place the mounting bracket at the desired height for the panel 2 Secure the mounting bracket to the surface Use all six mounting slots provided on the bracket To mount the FP1 panel on the bracket 3 Lift the mounting plate above the wall bracket 4 Slip the top of the mounting plate over the angled lip of the wall bracket 5 Secure the lower back flange of the mounting plate to the wall with appropriate hardware 6 Insert all three 1 inch nylon hole plugs into the rear slot access holes 900 0132 01 00 Rev A vsd Page 2 2013 01 17 2012 OutBack Power Technologies All Rights Reserved Wall Stud Y Wall Board Y Mounting the bracket to ae cas the wall studs 16 apart Wall Studd Wall Bbad centerto cenber 24 canter to panter i Mounting the bracketto the wall studs 24 apart ets Wall board Mounting the bracket to plywood Plyw ood if used FP1 Mounting Mounting Bracket Plate y Mounting Bracket
31. tBack Power Technologies no se hace responsable de aver as del sistema da os o lesiones resultantes de una instalaci n incorrecta de sus productos Aviso de Derecho de Autor Descripci n general del sistema de la FLEXpower ONE O Enero 2012 by OutBack Power Technologies Todos los derechos reservados Marcas comerciales OutBack Power es una marca comercial registrada de OutBack Power Technologies Fecha y revisi n Enero 2012 Revisi n A N mero de referencia 900 0094 02 00 Rev A Cut Back POWER member of The alpha Group Am rica del Norte 5917 195th Street N E Arlington WA 98223 USA 1 360 435 6030 900 0094 02 00 Rev A MATES Programming mpo OFLEXpower One IMPORTANT Programming should be done by a qualified installer who is trained on programming inverter power systems Failure to program accurate parameters for the A system could potentially cause equipment damage Damage caused by inaccurate programming is not covered by the limited warranty for the system FLEXnet DC HUB Communication Manager Ma or Co m p onents Battery Monitor HUB4 or HUB10 FLEXpower System Products eo Menu Configuration Hizard gt p y Device Data Logs Restore Can el opa Hen Configuration Inittalized Inverter Charger FX Series F iemeare Update gt k Cont inue 4 ware VFX Series GTFX Series GVFX Series GFX Series Off Grid Grid Tied Backup