Home

REMOTE THERMO SENSOR WITH LCD MODEL

image

Contents

1. 0 9 in 105 x 70 x 22 5 mm HxWxD CAUTION The content of this manual is subject to change without further notice Due to printing limitations the displays shown in this manual may differ from the actual display The manufacturer and its suppliers hold no responsibility to you or any other person for any damage expenses lost profits or any other claim as a result of using this product The contents of this manual may not be reproduced without the permission of the manufacturer ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products such as digital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes contact information for our Customer Care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the information you need on our website however if you re in the US and would like to contact the Oregon Scientific Customer Care department directly please visit www2 oregonscientific com service default asp OR Call 1 800 853 8883 For international inquiries please visit www2 oregonscientific com about international asp FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the fol
2. Inicie una b squeda coinciden con la manual de sensores unidad principal ESPECIFICACIONES Medici n de la temperatura Intervalo que se muestra en pantalla 50 C a 70 C 58 F a 158 F 30 C a 60 C 22 F a 140 F 0 1 C 0 2 F Intervalo de operaci n propuesto Resoluci n de temperatura Frecuencia de transmisi n de RF 433 MHz Cantidad de unidades remotas 3 como m ximo Alcance de transmisi n de RF 30 m 98 pies como m ximo Ciclo del sensor de temperatura 30 segundos aproximadamente Use 2 bater as alcalinas UM 3 AA de 1 5 V Peso 83 g 3 onzas sin bater as Dimensiones 105 x 70 x 22 5 mm 4 x 2 8 x 0 9 pulg H x Ax Prof Energia PRECAUCION El contenido de este manual est sujeto a cambios sin previo aviso Debido a limitaciones de impresi n las pantallas que se muestran en este manual pueden diferir de la pantalla real El fabricante y sus distribuidores no ser n responsables ante usted o ante otras personas por los gastos a causa de da os por las ganancias perdidas o por otros reclamos originados de la utilizaci n de este producto Esta prohibida la reproducci n del contenido de este manual sin el consentimiento del fabricante ACERCA DE OREGON SCIENTIFIC Visite nuestro sitio web www oregonscientific com para obtener m s informaci n sobre los productos de Oregon Scientific por ejemplo c maras d
3. unidad falla debido a una temperatura baja la unidad volver a funcionar correctamente cuando la temperatura suba y alcance un valor normal es decir la unidad no sufrir da os permanentes por las bajas temperaturas CAMBIO DE CANALES Una vez asignado un canal a una unidad nicamente podr cambiarlo extrayendo las bater as y repitiendo el procedimiento anterior ADVERTENCIA DE BATERIA BAJA Reemplace las bater as del sensor cuando el indicador de bater a baja del canal de dicho sensor se encienda en la unidad principal OPERACION Una vez colocadas las bater as el sensor comenzar a transmitir muestras a intervalos de 30 segundos La lectura del sensor remoto que aparece en la pantalla LCD depende del canal de sensor remoto que se haya elegido COMO RESTABLECER LA UNIDAD La funci n restablecer es necesaria nicamente cuando la unidad funciona mal o en forma incorrecta Para tener acceso 1 Levante la puerta del compartimiento de bater a 2 Coloque un punz n romo en el orificio donde dice RESTABLECER y presione 3 Vuelva a colocar la puerta del compartimiento Para obtener m s informaci n consulte el manual del usuario de la unidad COMO USAR EL SOPORTE PARA MESA O PARA EL MONTAJE EN LA PARED Este sensor viene con un soporte para montaje en la pared y un soporte desmontable para la mesa Use cualquiera de los dos para colocar la unidad en el lugar que desee FIG A PRECAUCIONES Si e
4. OreGcon REMOTE THERMO SENSOR WITH LCD MODEL THR138 User Manual FIGA INTRODUCTION Congratulations on your purchase of the THR138 Remote Thermo Sensor This Remote Thermo Sensor is for use with the 433 MHz Multi Channel In Out Thermometer to monitor temperature changes of outdoor sites Operation is easy and no wire installation is required COMPATIBLE UNITS Examples of compatible units are as follows MAIN FEATURES A TO m BEFORE YOU BEGIN EMR812A BAR888A RMR112A LCD Displays the current temperature monitored by the remote unit LED INDICATOR Flashes when the remote unit transmits a reading C F SLIDE SWITCH Selects between Centigrade C and Fahrenheit F CHANNEL SLIDE SWITCH Designates the remote unit Channel 1 Channel 2 or Channel 3 RESET BUTTON Returns all settings to default values BATTERY COMPARTMENT Accommodates two UM 3 AA size alkaline batteries BATTERY DOOR WALL MOUNT HOLDER Supports the remote unit in wall mounting REMOVABLE TABLE STAND For standing the remote unit on a flat surface To ensure proper reception between the main unit and the remote sensor follow these instructions carefully Battery and channel installation 1 2 or Place both units as close as possible to each other Assign a different channel to each remote sensor by changing the channel switch
5. er as o presione el bot n Restablecer de la unidad principal Siga las instrucciones estipuladas en el manual del usuario 6 Ubique el sensor remoto y la unidad principal dentro del alcance de transmisi n efectiva en circunstancias normales es de 30 metros 98 pies NOTA Observe que los materiales de construcci n y la posici n de la unidad principal o de los sensores remotos afectan el alcance efectivo de transmisi n Pruebe varias disposiciones de instalaci n para obtener mejores resultados Si bien el sensor es resistente a la intemperie y est dise ado para ser utilizado en el exterior no se debe colocar en lugares expuestos a la luz solar directa la lluvia o la nieve Las bater as alcalinas est ndar contienen grandes cantidades de agua Por este motivo puede ocurrir que se congelen en lugares de baja temperatura aproximadamente 12 C 10 F Las bater as de litio desechables tienen un umbral mucho m s bajo respecto a la temperatura se estima que se congelar n a temperaturas menores de 40 C 40 F La pantalla de cristal l quido de los term metros para exterior seguir funcionando a 29 C 20 F siempre que la unidad tenga la energ a adecuada El alcance del sistema inal mbrico se puede ver afectado por una variedad de factores como las temperaturas extremadamente fr as El fr o extremo puede reducir temporalmente el alcance efectivo entre el sensor y la estaci n base Si el rendimiento de la
6. es compatibles e EMR812A BAR888A RMR112A CARACTERISTICAS PRINCIPALES A PANTALLA LCD Muestra la temperatura actual controlada por la unidad remota B INDICADOR LED Parpadea cuando la unidad remota transmite una lectura C INTERRUPTOR DESLIZABLE C F Selecciona entre grado Centigrado C y Fahrenheit F D INTERRUPTOR DESLIZABLE DE CANALES Selecciona entre el Canal 1 Canal 2 o Canal 3 de la unidad remota E BOTON RESTABLECER Vuelve todos los par metros a los valores predeterminados F COMPARTIMIENTO DE BATERIAS Para dos bater as alcalinas UM 3 AA PUERTA DEL COMPARTIMIENTO DE BATERIAS SOPORTE DE MONTAJE EN LA PARED Sirve para fijar la unidad remota en la pared SOPORTE DESMONTABLE PARA MESA Sirve para apoyar la unidad remota sobre una superficie plana ANTES DE COMENZAR Para garantizar una recepci n correcta entre la unidad principal y el sensor remoto siga con detenimiento estas instrucciones TO Instalaci n de la bater a y del canal 1 Coloque ambas unidades lo m s cerca posible entre s 2 Asigne un canal diferente a cada sensor remoto seleccion ndolo con el interruptor de canales ubicado en el compartimiento de bater as del sensor remoto 3 En el interruptor deslizable C F seleccione la unidad de medida para la visualizaci n de la temperatura 4 Instale 2 bater as alcalinas UM 3 o AA de 1 5 V siguiendo estrictamente la indicaci n de polaridad 5 Inserte las bat
7. idad del usuario a operar el equipo NOTA Este equipo ha sido probado y se comprob que cumple con los l mites estipulados para un dispositivo digital Clase B conforme a la Parte 15 de las Reglas de la FCC Estos l mites est n dise ados para proporcionar protecci n razonable contra interferencias perjudiciales en una instalaci n residencial Este equipo genera usa y puede irradiar energ a de radiofrecuencia y si no se instala y utiliza de acuerdo a las instrucciones puede provocar interferencias perjudiciales en las comunicaciones de radio No obstante no se garantiza que no se producir n interferencias en una instalaci n en particular Si este equipo provoca interferencias perjudiciales en la recepci n de radio o televisi n lo que puede determinarse al encender o apagar el equipo se recomienda que el usuario intente corregirlas aplicando las siguientes medidas e Vuelva a orientar o a ubicar la antena receptora Incremente la distancia entre el equipo y el receptor e Conecte el equipo a un tomacorriente en un circuito distinto del que utiliz para conectar el receptor e Consulte al distribuidor o a un t cnico experto en radio TV para obtener ayuda La siguiente informaci n no se utilizar como contacto para soporte t cnico o ventas Para realizar todas sus consultas llame a nuestro n mero de atenci n al cliente mencionado en nuestro sitio web en www oregonscientific com o en la tarjeta de garant a de este
8. igitales reproductores MP3 productos y juegos de aprendizaje electr nicos para ni os relojes de proyecci n equipos para la salud y de gimnasia estaciones meteorol gicas tel fonos digitales y de conferencia El sitio web tambi n incluye informaci n de contacto de nuestro departamento de atenci n al cliente en caso de que necesite comunicarse con nosotros adem s de preguntas frecuentes y descargas para clientes Esperamos que en nuestro sitio web encuentre toda la informaci n que necesite no obstante si es residente de Estados Unidos y desea comunicarse directamente con el departamento de Atenci n del cliente de Oregon Scientific visite www2 oregonscientific com service default asp O Llame al 1 800 853 8883 Para consultas internacionales visite www2 oregonscientific com about international asp DECLARACION DE LA COMISION FEDERAL DE COMUNICACIONES FCC Este dispositivo cumple con la Parte 15 de las Reglas de la FCC Comisi n de Comunicaciones Federales El funcionamiento de la unidad queda sujeto a las dos condiciones siguientes 1 Es probable que este dispositivo no provoque interferencias perjudiciales y 2 Este dispositivo debe aceptar las interferencias que reciba incluso las interferencias que puedan provocar un funcionamiento no deseado ADVERTENCIA Los cambios o las modificaciones no aprobados en forma expresa por los responsables del cumplimiento de las normas pertinentes anular la autor
9. in the battery compartment of the remote sensor Select the units of measurement for the temperature display on the C F slide switch Install 2 alkaline batteries UM 3 or AA size 1 5V strictly according to the polarities shown Insert batteries or press the reset button of the main unit Follow the instructions as set out in the user s manual Position the remote sensor and main unit within effective transmission range which in usual circumstances is 98 feet 30 meters NOTE The effective range may be limited by building materials and the position of either the main unit or remote sensors Try various set up arrangements for best result Though the sensor is weatherproof and is meant for use outside it should be placed away from direct sunlight rain or snow Standard Alkaline batteries contain signifcant amounts of water Because of this they will freeze in low temperatures of approximately 10 F 12 C Disposable Lithium batteries have a much lower threshold for temperature with an estimated freezing range of below 40 F 40 C The Liquid Crystal Display in outdoor thermometers will remain operational to 20 F 29 C with adequate power Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures Extreme cold may temporarily reduce the effective range between the sensor and the base station If the units performance fails due to low temperature the unit will resume prope
10. l producto se manipula con el debido cuidado le proporcionar a os de servicio satisfactorio A continuaci n se describen algunas precauciones 1 No sumerja la unidad en agua 2 No limpie la unidad con materiales abrasivos o corrosivos Puede rayar las piezas de pl stico y corroer el circuito electr nico 3 No someta la unidad a fuerzas extremas golpes polvo temperatura o humedad Tales condiciones pueden ocasionar mal funcionamiento menor vida til respecto al sistema electr nico da os en las bater as o piezas deformadas 4 No golpee los componentes internos de la unidad Si lo hace puede da ar la unidad y la garant a quedar anulada La unidad no contiene piezas que el usuario pueda reparar 5 Utilice nicamente bater as nuevas seg n las especificaciones del manual de instrucciones No mezcle pilas nuevas con usadas No mezcle pilas alcalinas est ndar carb n cinc o recargables niquel cadmio 6 Antes de operar la unidad lea este manual de instrucciones detenidamente SOLUCION DE PROBLEMAS Verifique aqu antes de comunicarse con nuestro departamento de atenci n al cliente consulte la secci n Acerca de Oregon Scientific para obtener detalles de contacto PROBLEMA SINTOMA SOLUCI N Sensor remoto No se puede ubicar Verifique las bater as el sensor remoto Verifique la ubicaci n No se puede Examine todos los cambiar el canal sensores para un funcionamiento adecuado Los datos no
11. lowing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The following information is not
12. producto Nosotros Nombre Oregon Scientific Inc Direcci n 19861 SW 95th Ave Tualatin Oregon 97062 Estados Unidos N mero de tel fono 1 800 853 8883 declaramos que el producto N mero de producto THR138 Nombre del producto Sensor remoto Fabricante IDT Technology Limited Direcci n Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong cumple con la Parte 15 de las Reglas de la FCC Su funcionamiento queda sujeto a las dos condiciones siguientes 1 Es probable que este dispositivo no provoque interferencias perjudiciales 2 Este dispositivo debe aceptar las interferencias que reciba incluso las interferencias que puedan provocar un funcionamiento no deseado CE 2006 Oregon Scientific Todos los derechos reservados 086L001911 194
13. r functioning as the temperature rises to within the normal temperature range i e no permanent damage will occur to the unit due to low temperatures CHANGING CHANNELS Once a channel is assigned to a unit you can only change it by removing the batteries and repeating the above procedure LOW BATTERY WARNING Replace the batteries of the sensor when the low battery indicator of the channel represented by the sensor lights up on the main unit OPERATION Once batteries are in place the sensor will start transmitting samplings at 30 second intervals The remote sensor reading shown on the LCD depends on which remote sensor channel has been chosen HOW TO RESET THE UNIT The reset function is required only when the unit is operating in an unfavorable way or malfunctioning To access 1 Lift open the battery compartment door 2 Place a blunt stylus into the hole marked RESET and press 3 Replace the battery compartment door See the user s manual of your main unit for further information HOW TO USE THE TABLE STAND OR WALL MOUNT This sensor comes with a wall mount holder and a removable stand Use either to hold the unit in place FIG A PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully Here are a few precautions 1 2 Do not immerse the unit in water Do not clean the unit with abrasive or corrosive materials They may scratch the plastic par
14. to be used as contact for support or sales Please call our customer service number listed on our website at www oregonscientific com or on the warranty card for this product for all inquiries instead We Name Oregon Scientific Inc Address 19861 SW 95th Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 declare that the product Product No THR138 Product Name Remote Sensor Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation cE 2006 Oregon Scientific All rights reserved OreGcon SENSOR TERMICO REMOTO CON PANTALLA LCD MODELO THR138 Manual del usuario THERMO SENSOR 4aaMiz CABLE FREE e FIG A INTRODUCCION Felicitaciones por la compra del Sensor t rmico remoto THR138 Este sensor t rmico remoto se utiliza con el Term metro de interior y exterior de varios canales de 433 Mhz que sirve para controlar los cambios de temperatura en el exterior La operaci n es f cil y su instalaci n no requiere cables UNIDADES COMPATIBLES Estos son ejemplos de unidad
15. ts and corrode the electronic circuit Do not subject the unit to excessive force shock dust temperature or humidity Which may result in malfunction shorter electronic life span damaged battery and distorted parts Do not tamper with the unit s internal components Doing so will invalidate the warranty on the unit and may cause unnecessary damage The unit contains no user serviceable parts Only use fresh batteries as specified in the user s manual Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries Always read the user s manual thoroughly before operating the unit TROUBLESHOOTING PROBLEM SYMPTOM REMEDY Remote sensor Cannot locate Check batteries remote sensor Check location Cannot change Check all channel sensors for proper operation Data does not Initiate a manual match main unit sensor search SPECIFICATIONS Temperature Measurement Displayed range Proposed operating range Temperature resolution RF transmission frequency No of remote unit RF transmission range Temperature sensing cycle Power Weight Dimension 50 0 C to 70 0 C 58 0 F to 158 0 F 22 0 F to 140 0 F 30 0 C to 60 0 C 0 1 C 0 2 F 433 MHz maximum of 3 maximum of 98 ft 30 m around 30 seconds use 2pcs UM 3 AA 1 5V alkaline batteries 3 oz 83 g without batteries 4x 2 8 x

Download Pdf Manuals

image

Related Search

Related Contents

Saldatura e taglio ossigas Cannelli componibili  Ironite 100099050 Use and Care Manual  

Copyright © All rights reserved.
Failed to retrieve file