Home
Modelo PR-1 - Chauvin Arnoux Group
Contents
1. 2 2 Caracter stica del Producto 3 ESPECIFICACIONES 16 3 1 Especificaciones Generales 16 4 OPERACI N 4 1 Operaci n del Modelo PR 1 17 5 MANTENIMIENTO 18 5 1 Advertencia u u a a base Da etie Der b sen 18 5 2 LIM PIO Zeist ries ceret 18 5 3 Reemplazar el 18 Reparaci n y CalibraeI fy l ul 19 Asistencia t cnica y venta 19 Garantia 20 Garant a de Reparaci n cse ee net Ea nate aus 20 Modelo PR 1 Medidor De Rotaci n De Fase 11 CAPITULO 1 INTRODUCCI N ZN ADVERTENCIA N Lea el manual antes de empezar a utilizar el instrumento y siga todas las informaciones de seguridad Utilice el instrumento como se indica en el manual No utilice el instrumento o las puntas de pruebas si para cen da adas Este instrumento a sido dise ado y comprobado siguiendo todos los requerimientos de IEC Publicaci n 348 Reque rimientos de Seguridad para Aparatos de Medida Electr nica IEC 1010 EN61010 y otros est ndar de seguridad Siga todas las advertencias de seguridad 1 1 S mbolos El ctricos Internacionales
2. PHASE ROTATION 1 METER P R ENGLISH User Manual AEMC ESPA OL Manual de instrucciones INSTRUMENTS i Statement of Compliance i Chauvin Arnoux Inc d b a AEMC Instruments x certifies that this instrument has been calibrated x using standards and instruments traceable to X international standards We guarantee that at the time of shipping your x dt if instrument has met its published specifications y X The recommended verification interval for this X X instrument is 12 months and begins on the date X of receipt by the customer For verification please x use our calibration services Refer to our repair and calibration section at www aemc com 4 c Serial x Catalog 2121 06 X J Model PR 1 0 JC JV Please fill in the appropriate date as indicated d Date Received X x Date Verification Due at y X Y C qe JA Jt X G AEMC Xx i Chauvin Arnoux Inc d b a AEMC Instruments x WWW aemc com Table of Contents 1 INTRODUCTION 2 1 1 International Electrical Symbols 2 1 2 Definition of Measurement Categories 3 1 3 Receiving Your Shipment uu u u uuu as 3 1 4 Ordering Information eet oe tae 3 2 PRODUCT FEATURES
3. Este s mbolo significas que el instrumento esta protegido con doble aislamiento Este s mbolo en el instrumento indica una ADVERTENCIA y que el operador deber consultar el manual del usuario para obtener instrucciones antes de utilizar el instrumento En este manual el s mbolo anterior a las instrucciones indica que si las instrucciones no se siguen se pueden provocar lesi n corporal y tambi n se pueden provocar da os en los productos Peligro Riesgo de shock el ctrico La tensi n en la parte marcada con este s mbolo puede ser peligroso De conformidad con WEEE 2002 96 EC Dx Pg 12 Modelo PR 1 Medidor De Rotaci n De Fase 1 2 Definici n de las Categor as de Medici n Cat l Para las mediciones de los circuitos que no est n directa mente conectadas a la red de suministro tales como toma de corriente secundarias protegida de nivel y circuitos con limitaci n de corriente Cat Il Para las mediciones realizadas en los circuitos conectado directamente al sistema de distribuci n el ctrica Ejemplos de ello son las mediciones de los aparatos dom sticos o ins trumentos port tiles Cat Para las mediciones realizadas en la construcci n de la ins talaci n a nivel de distribuci n tales como la configuraci n en un equipo de instalaci n fija y disyuntores Cat IV Para las mediciones realizadas en el principal suministro el ctrico 1000 como en los dispositivos de protecci n de s
4. 1 4 Ordering Information Phase Rotation Meter Model PR 1 Cat 2121 06 Includes meter with attached 5 ft color coded leads and attached alli gator clips soft carrying case and user manual Phase Rotation Meter Model PR 1 3 CHAPTER 2 PRODUCT FEATURES 2 1 Control Features RED 600V PHASE ROTATION METER MODEL PR 1 INSTRUMENTS Color coded leads black red blue Lead strain relief Live Open phase indicators Phase rotation indicators I0 No 4 Phase Rotation Meter Model PR 1 22 Product Features The Phase Rotation Meter Model PR 1 is a compact and rugged meter designed to identify phase rotation on 3 Phase systems and identify live and open de energized phases Ideal for installing rotating machinery or motors and for checking generator output Phase rotation LED indicators ABC or BAC Bright LED indication Live or Open Phase A B C Fused protected inputs Color coded leads and alligator clips Loss proof attached leads Simple operation Line supplied no battery 600V Cat III rated and CE Mark Phase Rotation Meter Model PR 1 5 CHAPTER 3 SPECIFICATIONS 3 4 General Specifications Input Voltage 100 to 600Vac NOTE LEDs are dim at lower voltages Frequency Range 45 to 70Hz Live Open Phase Indication A B C Phase Rotation Indication BAC and ABC Powe
5. 2 1 Control F at les neret cis 2 2 Product Features iine erect 5 3 SPECIFICATIONS 6 3 1 General Specifications 6 4 OPERATION 4 1 Operating the Model 1 7 5 MAINTENANGCE T 8 511 cd 8 5 2 COM iii 8 E decode ea 8 Repair and 9 Technical and Sales Assistance vcneno 9 Limited RR RE 10 10 Phase Rotation Meter Model 1 CHAPTER 1 INTRODUCTION A Warning A Read the user manual before operating and follow all safety information Only use the meter as specified in this user manual Do not operate the meter if the body or test leads look damaged This meter has been designed and tested according to IEC Publication 348 Safety Requirements for Elec tronic Measuring Apparatus IEC 1010 EN61010 and other safety standards Follow all warnings to ensure safe operation 1 International Electrical Symbols Signifies that the instrument is protected by double or reinforced insulation This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument In this manua
6. AEMC Instruments will at its option repair or replace the faulty material REGISTER ONLINE AT www aemc com Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by fax from our Service Department see address below then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to Chauvin Arnoux Inc d b a AEMC Instruments Service Department 15 Faraday Drive Dover NH 03820 USA Tel 800 945 2362 or 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 repair aemc com Caution To protect yourself against in transit loss we recommend you insure your returned material NOTE All customers must obtain a CSA before returning any instrument 10 Phase Rotation Meter Model PR 1 Tabla de Contenidos 1 INTRODUCCI N u QU QQ uu 12 1 1 S mbolos El ctricos Internacionales 12 1 2 Definici n de las Categor as de Medici n 13 1 3 Comprobaci n de su 13 1 4 Informaci n del 13 2 CARACTER STICAS DEL PRODUCTO 2 1 Caracter sticas del Controles
7. Instruments no por el dis tribuidor al cual fue comprado el instrumento Esta garant a puede ser cancelada si la unidad a sido mal tratada o defectuosa por uso inde bido o por reparaciones no efectuadas por nuestro servicio t cnico de AEMC Instruments Para un mayor detalle de la cobertura de la garant a y registracion vaya a www aemc com Que puede hacer AEMC Si el mal funcionamiento ocurre durante el periodo del a o deber devolver la unidad a nosotros para reparaci n sin costo alguno aseg rese de mandarnos la Tarjeta de Registro AEMC Instruments podr decidir reparar la unidad o reemplazarla Garant a de Reparaci n Que debe hacer para devolver el instrumento para ser reparado bajo la garant a Primero adquiera el Numero de Autorizaci n del Servicio al Cliente CSA por tel fono o por fax desde nuestro Departamento de Servicios ver direcci n adjunta despu s devuelva el instrumento con la autorizaci n CSA firmada Por favor escriba el CSA en el exte rior del embalaje Devuelva el instrumento con los portes y seguros prepagados a Advertencia Para protegerse usted mismo por perdida del instru mento en transito le recomendamos que lo asegure NOTA Todos los clientes deber n obtener el CSA antes de devolver el instrumento 20 Modelo PR 1 Medidor De Rotaci n De Fase G INSTRUMENTS 08 08 99 MAN 100276 v4 Chauvin Inc d b a AEMC Instruments 15 Faraday Drive
8. any servicing unless you are qualified to do so To avoid electrical shock and or damage to the instrument do not get water or other foreign agents into the meter 5 2 Cleaning To clean wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents 5 3 Fuse Replacement e The fuses will need to be replaced when LED indicators show no connection e Use a screwdriver to unscrew the screws on the back of the case e Open the case and replace both fuses with 200mA 250V fuses 8 Phase Rotation Meter Model PR 1 Repair and Calibration To ensure that your instrument meets factory specifications we recommend that it be submitted to our factory Service Center at one year intervals for reca libration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T includes calibration certificate plus recorded calibration data Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 945 2362 or 603 749 6434 Ext 360 Fax 603 742 2346 or 6
9. 03 749 6309 repair aemc com Or contact your authorized distributor Costs for repair standard calibration and calibration traceable to N I S T are available NOTE A CSA must be obtained before returning any instrument Technical and Sales Assistance e e If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument please call mail fax or e mail our technical support hotline Chauvin Arnoux Inc d b a AEMC Instruments 200 Foxborough Boulevard Foxborough MA 02035 USA Phone 800 343 1391 or 508 698 2115 Fax 508 698 2118 techsupport aemc com www aemc com NOTE Do not ship Instruments to our Foxborough MA address Phase Rotation Meter Model PR 1 9 limited Warranty ET The Model PR 1 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture This limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments For full warranty coverage detail and registration go to www aemc com What AEMC Instruments will do If a malfunction occurs within the one year period you may return the instrument to us for repair provided we have your warranty registration information or a proof of purchase
10. Dover NH 03820 USA www aemc com
11. e hay una Fase Viva o Abierta A B C Entrada protegidas por fusible Conductor con clips tipo cocodrilo y con c digo de color Conexi n fija F cil manejo L nea suministrada no bater a 600V Cat IIl nominal y sello de CE Modelo PR 1 Medidor De Rotaci n De Fase 15 CAPITULO 3 ESPECIFICACIONES 3 1 Especificaciones Generales Voltaje de Entrada 100 600Vac Los LED lucen poco con bajas tensiones Rango de Frecuencia 45 70Hz Indicaci n de Fase Vivo Abierto A B C Indicaci n de Rotaci n de Fase BAC y ABC Dimensiones 4 x 3 x 1 25 102 x 78 x 32mm Peso 4 oz 954 aprox Conexiones 5 conexiones terminados en clips aislados del tipo cocodrilo Temperatura 32 104 F 0 40 C Humedad Relativa 8096 RH Altitud 6000 ft 2000m Seguridad Doble aislamiento IEC 1010 EN61010 600V Grado de Poluci n 2 Suministra Bolsa de mano y manual del usuario 16 Modelo PR 1 Medidor De Rotaci n De Fase CAPITULO 4 OPERACI N 41 Operaci n del Modelo PR 1 1 Conecte el conector de tipo de cocodrilo a uno de los terminales de fuente de potencia de 3 fases Todos los LED encendidos La fase no esta abierta LED negro desconectado Fase abierta y sin energia en el terminal donde el clip negro esta conectado LED rojo desconectado Fase abierta y sin energia en el terminal donde el clip rojo este conectado LED azul desconectado Fase abierta y sin energia en el terminal d
12. ecomendamos que se mande a nuestro Servicio T cnico en intervalos de un a o para recalibrarlos o por requerimientos de otro est ndar o procesos internos Para reparaci n o calibraci n de instrumentos Deber contactar con nuestro Centro de Servicios para obtener el Numero de Autorizaci n del Servicio al Cliente CSA Este asegurara que cuando recibamos el instrumento ser procesado r pidamente Por favor escriba el CSA por fuera del embalaje Si el instrumento es mandado para calibraci n necesitamos saber el modelo de cali braci n que desea calibraci n est ndar o calibraci n para N I S T Incluye certificado de calibraci n mas la informaci n recogida al ser calibrado Contacte su distribuidor autorizado El coste por reparaci n calibraci n est ndar y calibraci n N I S T est n disponibles NOTA Todos los clientes deber n obtener el CSA antes de devolver el instrumento Asistencia t cnica y venta Si tiene cualquier problema t cnico o requiere de ayuda para una operaci n o aplicaci n determinada con el instrumento por favor ll menos correos fax o e mail a nuestro servicio t cnico NOTA No mande el instrumento a nuestra direcci n de Foxborough MA Modelo PR 1 Medidor De Rotaci n De Fase 19 Garant a Limitada El Modelo PR 1 esta garantizado por el periodo de un a o desde la fecha de su adquisici n y solamente por defectos de fabricaci n Esta garant a limitada es dada por AEMC
13. l the symbol preceding instructions indicates that if the instructions are not followed bodily injury installation sample and or product damage may result Risk of electric shock The voltage at the parts marked with this sym bol may be dangerous In conformity with WEEE 2002 96 EC Ex PB 2 Phase Rotation Meter Model PR 1 1 2 Definition of Measurement Categories Cat For measurements on circuits not directly connected to the AC supply wall outlet such as protected secondaries signal level and limited energy circuits Cat 1 For measurements performed on circuits directly connected to the electrical distribution system Examples are measure ments on household appliances or portable tools Cat Ill For measurements performed in the building installation at the distribution level such as on hardwired equipment in fixed installation and circuit breakers Cat IV For measurements performed at the primary electrical supply lt 1000V such as on primary overcurrent protection devices ripple control units or meters 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consis tent with the packing list Notify your distributor of any missing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim
14. obrecorriente primaria unidades de control de ondulaci n o medidores 1 3 Comprobaci n de su pedido Una vez recibido su pedido verifique que el pedido este completo Llame al distribuidor si no estuviera completo Si la mercanc a parece estar da ada reclame a la empresa que le entrego la mercanc a y llame su distribuidor d ndole con todo detalle de los da os 1 4 Informaci n del pedido Medidor de Rotaci n de Fase Cat 2121 06 Incluye medidor bolsa cable de 5 pies con el c digo de colores y clips de tipo cocodrilo y el manual del usuario Modelo PR 1 Medidor De Rotaci n De Fase 13 CAPITULO 2 CARACTER STICAS DEL PRODUCTO 2 1 Caracter sticas del Controles PHASE ROTATION METER ODEL PR Cables c digo de color negro rojo azul Aliviador de tensi n del cable Indicadores de fase Viva Abierta Indicadores de rotaci n de fase SINS 14 Modelo PR 1 Medidor De Rotaci n De Fase 22 Caracter stica del Producto EI Medidor de Rotaci n de Fase Modelo PR 1 es un medidor com pacto y robusto dise ado para identificar la rotaci n de fases en sis temas trif sicos e identificar pases vivas y abiertas no energizadas Ideal para la instalaci n de maquinaria rotatoria o motores y para comprobar la salida de generadores Rotaci n de Fase ABC BAC Un LED encendido le indica qu
15. onde el clip azul este conectado 2 Compruebe los indicadores de Rotaci n de Fase En el caso de que el LED de indicaci n BAC este encen dido Cambie la conexi n de dos de los tres conectores tipo cocodrilo En el caso de que el LED de indicaci n ABC este encen dido La secuencia de fase es A B C en orden de los termi nales de la fuente de potencia donde los terminales del tipo cocodrilo NEGRO ROJO y AZUL est n conectados Modelo PR 1 Medidor De Rotaci n De Fase 17 CAPITULO 5 MANTENIMIENTO 5 1 A Advertencia Desconecte los cables de prueba de cualquier entrada antes de abrir la caja No opere el medidor sin la cubierta Para evitar choque el ctrico no intente hacer ninguna reparaci n a menos que est calificado para hacerlo Para evitar choque el ctrico y o da ar el instrumento no deje entrar agua ni otros agentes extra os al interior del instrumento 5 2 Limpieza Para limpiarlo frote la caja con un pa o h medo y un detergente suave No utilice abrasivos ni solventes 5 3 Reemplazar el Fusible Cuando los indicadores LED indican sin conexi n se necesita reemplazar los fusibles Use un destornillador para retirar los tornillos de la parte posterior de la caja Abra la caja y reemplace ambos fusibles por fusibles de 200mA 250V 18 Modelo PR 1 Medidor De Rotaci n De Fase Reparaci n y Calibraci n Para asegurar que su instrumento cumple las especificaciones de la empresa r
16. r Source Powered from circuit under test Dimensions 4 x 3 x 1 25 102 x 78 x 32mm Weight 4 oz 95g approx Leads Attached 5 ft terminated with insulated alligator clips Temperature 32 to 104 F 0 to 40 C Relative Humidity 8096 RH Altitude 6000 ft 2000m Safety Double Insulation IEC 1010 EN61010 600V Cat III Pollution Degree 2 Supply Includes soft carrying case and user manual 6 Phase Rotation Meter Model PR 1 CHAPTER 4 OPERATION 41 Operating the Model PR 1 1 Connect the alligator clips to the terminals of a 3 Phase power Source All LEDs ON Phases live Black LED OFF Open Non energized phase on terminal where BLACK alligator clip is connected Red LED OFF Open Non energized phase on terminal where RED alligator clip is connected Blue LED OFF Open Non energized phase on terminal where BLUE alligator clip is connected 2 Check the Phase Rotation Indicators If the BAC indication LED is ON Alternate the connection of any two of the three alligator clips If the ABC indication LED is ON Phase sequence is A B C in order of the power source terminals where the BLACK RED and BLUE alligator clips are connected Phase Rotation Meter Model PR 1 7 CHAPTER 5 MAINTENANCE 5 1 AN Warning Remove the test leads from any input before opening the case Do not operate the meter without the case cover To avoid electrical shock do not attempt to perform
Download Pdf Manuals
Related Search
Related Contents
Actualité du premier chapitre du Traité politique de Spinoza Handleiding Classic Power Nition CITROEN TA Perfo/11D Makita 6932FDWDE User's Manual Simulation du coût et du financement public des ateliers et Actes JNP 2012 - Le blog des parents d`enfants en situation de 取扱説明書[MC-SU120A] (7.31 MB/PDF) Polaroid izone550 User's Manual Pêche en mer. La VHF en accès libre Fisher Price M8581 toy USER GUIDE Copyright © All rights reserved.