1. 2 3 Installation Before installation please read carefully the following instructions gt Placement The UPS must be installed in a protected environment away from heat emitting appliances such as a radiator or heater Do not install this product where excessive moisture is present gt Ventilation The location should provide adequate air flow around the UPS with one inch minimum clearance on all sides for proper ventilation gt Charge the Battery A new UPS may be used immediately upon receipt However charge loss may occur during shipping and storage So charging the battery for at least 8 hours is recommended to insure that the battery is fully charged To recharge the battery simply leave the unit plugged into an AC outlet This UPS will recharge in both the On and the Off status 18 gt Connect to AC 2 Make sure that the voltage and frequency are correct Plug the UPS into a 2 pole 3 wire grounding receptacle wall outlet Make sure the wall outlet branch is protected Avoid using extension cords if at all possible If used make sure the extension cord is rated for 15 Amps Use the supplied input cord IEC female European UK to connect the UPS 10 to the mains Do not plug a laser printer or copy machine into the outlets of this UPS The power demands of these particular devices are much higher than typical peripherals Setting voltage and Frequency FUNCTION 3 2 1 4 o did
2. LINE Ei bips Etat k Mode Normal secteur normal A Erreur de polarit ou de mise la terre gt 1bip 2 secondes Mode Batterie d faut du secteur A 1bip 1secondes Mode Batterie d faut du secteur arr t imminent Batterie faible A En attente du retour de secteur pour un red marrage automatique E x Bip continu Surcharge court circuit ou anomalie du voltage en sortie x Remplacement des batteries n cessaire Batteries faibles recharge n cessaire allum clignotant Eteint L alarme sonore peut tre arr t e lors du Mode Batterie en appuyant sur le bouton de mise en marche pendant environ une seconde A moins qu une nouvelle alerte doive tre signal e l onduleur restera silencieux 4 Entretien et maintenance 4 1 Maintenance gt Utilisez un chiffon sec pour le nettoyage des parties plastiques N utilisez pas de d tergent ou de produits contenant de l alcool La dur e de vie moyenne d une batterie est de 3 ans Une mauvaise utilisation ou un environnement extr me peuvent r duire cette dur e de vie D branchez l onduleur si il ne doit pas servir pendant un p riode prolong e Rechargez les batteries tous les 3 mois lors d un stockage de longue dur e Lors du remplacement de la batterie utilisez une batterie au plomb tanche sans maintenance de m me voltage et de m me puissance gt Avant la mise au rebut
3. 22 6 Specification Model DELTA 800 DELTA 1100 DELTA 1400 DELTA 2200 DELTA 3000 Capacity 800 VA 1100 VA 1400 VA 2200 VA 3000 VA Technology Type Online system mono conversion Input Nominal Voltage 220 230 240 V Voltage Range 190 240V 198 250V 207 262V 5V Frequency Range 50 60 Hz 3Hz Nominal Voltage 220 230 240 V 6V Output Frequency Stability 50 60 Hz 0 1 Waveform True sine wave Transfer Time lt 4 ms typical Type Sealed Maintenance free Lead Acid Battery DC Voltage 12V 7Ah x2 12V 7Ahx2 12V 9Ah x2 12V 7Ah x4 12V 9Ah x4 User s Replacement Yes Recharge time 2 4 hours to 90 Overload prot Normal mode gt 110 for 10 minutes then shutdown Battery mode gt 110 for seconds then shutdown Short circuit prot Normal mode Input fuse amp Electronic circuit Battery mode Electronic circuit Communication Intelligent Interface USB PNP amp RS232c auto switch Compatible O S Windows 95 98Me XP NT 2000 2003 Linux FreeBSD Novell Safety standard EN50091 1 Safety EMC EN50091 2 Mark CE Temperature 0 40 C Environment Humidity 0 95 R Humidity Non condensing Dimension D W H 173x247x369 173x247x472 Net Weight 14 7 kg 15 kg 16 kg 23 kg 25 kg 23 www unitek power com v 2 1 0504 24
4. gt Mode normal L onduleur alimente les appareils connect s depuis le secteur et charge ses batteries Il r gule le courant de sortie dans une plage de voltage troite et isole les appareils connect s des bruits et des pics de tension issus du secteur gt Mode batterie l onduleur fonctionne en mode batterie quand le voltage ou la fr quence du secteur sortent des plages de tol rance Des alertes visuelles et sonores sont alors d clench es L onduleur fournit alors un courant r gul gr ce ses batteries Allumer Appuyer et maintenir enfonc le bouton de mise en marche 3 sur le panneau frontal pendant 3 secondes Attendre que le panneau LCD s allume puis s teigne Rel cher le bouton Le voyant Mode Batterie s allume et l onduleur entre en mode auto test Si le secteur est normal l onduleur repassera en Mode Normal apr s la fin de l auto test Si par contre il existe un anomalie sur le secteur coupure onduleur passera en Mode Batterie et mettra un bip toutes les 2 secondes Test Lorsque le secteur est normal appuyer sur le bouton de mise en marche 3 pendant 3 secondes pour que l onduleur ex cute un auto test de ses batteries Si celles ci sont normales l onduleur se mettra en Mode Batterie pendant 10 secondes puis reviendra en Mode Normal Si le voltage des batteries est plus bas que la limite fix e l ic ne Batterie faible 8 clignotera pendant 5 seconds puis l onduleur reviendra en Mode Normal Si
5. Reencendido automatico El SAI arrancar nuevamente autom ticamente proveyendo energ a si la electricidad se recupera 24 horas despu s del apagado autom tico La bater a parpadear cada 5 minutos durante este per odo Si la red el ctrica no regresa en 24 horas la funci n de reencendido autom tico no funcionar y se necesitar hacerlo manualmente Si no se necesita la funci n de reencendido autom tico sta puede ser cancelada apagando el SAI 2 5 Simulaci n manual de apag n Para probar la funci n de backup puede desenchufar el SAI de la red el ctrica o simplemente usar el bot n de la funci n de test descrita en la secci n anterior Si se deja el SAI funcionando continuamente es una buena idea testear peri dicamente la unidad por lo menos una vez a la semana Observe que su equipo est funcionando correcta e ininterrumpidamente durante este per odo Reenchufe el SAI si la test se ha hecho desenchufandolo gt gt gt gt gt Encienda el SAI y desench felo de la red el ctrica para simular un apag n Cuando ocurre un apag n la energ a es suministrada a su equipo por la bater a del SAI La alarma sonar cada 2 segundos y el icono de Modo de bateria parpadeara cada cinco segundos recordandole que su equipo esta funcionando con una fuente de poder limitada Si la corriente el ctrica no se restablece la alarma cambiara su frecuencia a un pitido por segundo alertando al usuario de que e
6. Puerto de comunicaci n RS232 Bot n de reajuste de CPU Interno Presione para apagar Interruptor de salida Tomas de salida Etiqueta de caracter sticas Fusible de entrada 0 Cable de Potencia de Entrada Toma de entrada 2 3 Instalaci n Antes de realizar la instalaci n por favor lea y estudie las siguientes instrucciones 1 cable de red RJ45 1 cable de comunicaci n USB 1 cable de comunicaci n RS232 1 CD de software UPSILON 2000 10 11 12135142 15 3 Ubicaci n El UPS debe ser instalado en un ambiente protegido lejos de fuentes de calor como radiadores o gt gt calentadores No instale este producto donde haya humedad excesiva Ventilaci n El lugar de instalaci n debe proveer una corriente de aire adecuada alrededor del UPS para que este pueda ventilarse adecuadamente m nimo una pulgada de despeje en cada lado Carga de las Bater as Esta unidad es enviada desde la f brica con su bater a totalmente cargada sin embargo algo de carga se pudo haber perdido durante el env o por lo que la bater a debe ser recargada antes de ser usada Para ello conecte la unidad a una toma de corriente apropiada y permita al UPS cargar totalmente las bater as dej ndolo conectado al menos 8 horas sin carga conectada Este UPS se recargara cuando este apagado o encendido 12 gt Conexi n al AC comercial Aseg rese que el voltaje y la frecuencia sean correc
7. es par cet onduleur sont recyclables Elles contiennent du plomb et de l acide tous deux dangereux pour l environnement et la sant Leur mise au rebus doit donc tre prise en charge par un service comp tent dans le recyclage de ce type de d chet L onduleur doit tre install dans un environnement contr l r f rez vous au chapitre correspondant de ce manuel pour plus de d tails Pendant l installation de cet appareil on s assurera que la somme totale des fuites lectriques par dispersion de l onduleur et des charges connect es n exc de pas les 3 5 mA y yy y y y Cet appareil g n re utilise et peut mettre des fr quences radio S il n est pas install conform ment aux instructions il peut provoquer des interf rences au niveau des communications radio Toutefois il n existe pas de garantie que ces interf rences ne se produiront pas Si cet appareil causait des interf rences dans la r ception de la radio ou de la t l vision ce qui peut tre d termin en allumant et teignant l onduleur une ou plusieurs des mesures suivantes peuvent tre prises pour corriger le probl me gt R orienter ou d placer l antenne de r ception gt Augmenter l espace s parant l appareil et le r cepteur gt Brancher l appareil sur une prise d pendant d un circuit diff rent de celui du r cepteur gt Consulter votre distributeur ou un technicien TV Radio Le fonctionnement s r et continu de l onduleur d pend par
8. Push the Off Switch 4 for at least 3 seconds to turn off the UPS If you press the Off Switch less than 3 seconds the UPS will not shutdown NOTE In some occasions the UPS will shut itself down in case of overload output short circuited or battery cut off point reached in the Backup mode The UPS will automatically shut off the output and beep for 5 seconds then completely shut itself down Cold Start This UPS can be turned on even when AC is not present gt Auto restart The UPS will automatically restart providing energy to the output if the utility recovers in 24 hours after automatic shutdown The Battery will flash every 5 seconds during this period If utility power doesn t return within 24 hours auto restart function will not work Manual startup will be required If UPS auto restart is not needed this function can be cancelled by turning off the UPS see above 19 2 5 Manual Simulation of Power Outage for the UPS To test the backup function you may unplug the power cord of the UPS or simply use the test function described in the previous section If the UPS is left to run continuously it is a good idea to perform a periodic function test on the unit at least once a week Observe that your equipment operates properly and uninterrupted during this period Plug the power cord back in if the function test was performed by unplugging it To conduct a simulation test gt Switch the UPS on the UP
9. The voltage 220 230 240 Vac amp frequency VOLTAGE 220V ti 4 in 50 60 Hz ofthe UPS must be set by the DIP VOLTAGE 230V HA e GI Switch on the rear panel of the UPS Use the VOLTAGE 240V 4 chart on the right to set the UPS voltage and FREQUENCY 50 Hz 4 frequency according to your needs FREQUENCY 60 Hz Connect the Load Plug your primary equipment e g computer monitor critical data storage device etc into the Battery Power Protected outlets 7 Leave the power switches of the equipment in the Off position for the moment Connect to Computer Use the enclosed RS 232 or USB cable Plug one end into the UPS 2 3 and the other one into the appropriate port on the computer Once a port is enabled the other one automatically disabled Connect the Fax Modem DSL Lines To protect a fax modem DSL line connect the RJ11 telephone cable from the wall outlet to the IN RJ45 RJ11 socket of the UPS 1 Connect the telephone cable from the OUT RJ45 RJ11 socket of the UPS 1 to the fax modem DSL line Connect Network Lines To protect a network connect the RJ45 network cable from the network system to the IN RJ45 RJ11 socket of the UPS 1 Connect the network cable from the OUT RJ45 RJ11 socket of the UPS 1 to the network station 2 4 Operation and Functional Test gt AC Mode The UPS delivers power to the loads derived from the utility and maintain
10. be replaced S 3 amp gt gt am gt gt p gt a gt gt Please do not open the metal cover There are no user serviceable parts inside The batteries contained in this UPS are recyclable The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly Do not open or mutilate the batteries They contain an electrolyte which is toxic and harmful to the skin and eyes A battery can present a risk of electrical shock and high short circuit current When replacing batteries wrist watches and jewelry such as rings should removed Use tools with insulated handles Please note the following information when you call for service Model Name and Serial Number Date and place of purchase Full description of problem 21 Abnormal Situation Cause Solution UPS shutdowns immediately ON switch does not work and there is no alarm DIP Switch setting error Set correct Voltage and frequency on the DIP Switch 2 UPS can not be turned on and LCD panel does not light ON button 3 switch was not pressed or pressed less than 3 seconds Press and hold the Main On switch for more than 3 seconds Battery voltage is too low Recharge the battery for at least 4 hours Battery is not connected properly Check that battery connectors are fully engaged UPS is not connected to AC Power supply Check that the power cable from the UPS to
11. before servicing the battery or installing a computer interface cable Do nat dispose of battery or batteries in fire The batteries may explode To reduce the risk of fire replace only with same type and rating of fuse The batteries used by this Uninterruptible Power System are recyclable Proper disposal of the batteries is required The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly Please refer to local codes for proper disposal requirement or return the unit to a factory authorized Service Center for battery replacement or disposal Intended for installation in a controlled environment Refer to manual for environmental conditions During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected load does not exceed 3 5mA yyy y y y y This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with the instructions this unit may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures gt Reorient or relocate the receiving antenna 3 Increase
12. des batteries usag es prenez soin de consulter la l gislation en vigueur yyy y 4 2 Remplacement des batteries Lorsque le voyant de remplacement des batteries s allume laisser l onduleur recharger ses batteries pendant 8 10 heures Effectuer alors un auto test en red marrant l onduleur Si l ic ne reste allum cela signifie qu il faut changer les batteries Il faut alors d visser le panneau avant de l onduleur et remplacer les batteries Appuyer ensuite sur le bouton de mise en marche pour faire dispara tre l ic ne Suivre les indications ci dessous pour remplacer les batteries Utiliser un tournevis cruciforme pour d solidariser le panneau frontal Retirer le panneau frontal de l onduleur Retirer les 4 vis comme indiqu ci dessus Retirer la plaque de protection des batteries Tirer l g rement le tiroir des batteries D brancher la cosse n gative en vous assurant qu elle n entre pas en contact avec la borne positive D brancher la cosse positive et retirer compl tement le tiroir pour y placer des batteries neuves R p ter cette proc dure en sens inverse pour terminer le remplacement des batteries NO O1 R D N inversez jamais le rouge et le noir lors du branchement sur une batterie Une fois la batterie d branch e les appareils connect s ne sont plus prot g s 4 2 Stockage Si vous souhaitez stocker l onduleur il existe un risque que ses batteries se d chargent d
13. finitivement Afin de pr venir cet inconv nient il convient de suivre les recommandations suivantes 1 Chargez pleinement les batteries avant de stocker l appareil 2 Rechargez les batteries pendant 12 heures et ce une fois tous les 3 mois 2 mois en pays chauds 5 R solution de probl me La table de r solution de panne ci dessous couvre la plupart des difficult s que vous pourrez rencontrer lors d une utilisation normale de votre onduleur Si votre onduleur ne fonctionne pas correctement veuillez v rifier les points suivants avant de faire appel aux services de maintenance 1 L onduleur est il branch une prise qui fonctionne 2 Le voltage du secteur correspond il aux sp cifications de l onduleur 3 Le fusible l arri re de l onduleur doit il tre remplac Les batteries utilis es par cet onduleur sont recyclables Elles contiennent du plomb m tal dangereux pour la amp N ouvrez pas votre onduleur Il ne contient pas de pi ces interchangeables E sant Elles doivent donc tre confi es un service comp tent lors de leur mise au rebut a Evitez d ouvrir ou d endommager les batteries Elles contiennent des lectrolytes toxiques pouvant occasionner des l sions de la peau et des yeux Les batteries peuvent pr senter des risques de court circuit et de chocs lectriques Lors de leur remplacement retirez montres bagues ou autres objets et utilisez des outils au manche isol Avant d
14. les appareils connect s fonctionnent correctement et sans interruption Rebrancher l onduleur la fin du test si celui ci a t r alis en l isolant du secteur Comment effectuer une simulation de panne gt Mettez votre onduleur en marche D branchez alors l onduleur de la prise murale pour simuler une coupure de courant gt Lors d une panne de secteur l onduleur fournit imm diatement du courant partir de ses batteries aux appareils connect s L onduleur mettra un bip toutes les 2 secondes vous rappelant que vos appareils ne disposent que d une quantit limit e de courant gt Sile courant n est pas r tabli les bips s acc l reront pour vous signaler l affaiblissement des batteries L arr t automatique de onduleur est alors imminent gt Pendant la coupure Sauvegardez et fermez manuellement les fichiers sur lesquels vous tes en train de travailler et fermez votre ordinateur Eteignez alors l onduleur pour pr server ses batteries en vue d un usage ult rieur gt Re tablissez l alimentation de vos appareils en rebranchant l onduleur sur la prise murale Sauvegardez tous vos fichiers importants avant d effectuer cette simulation Si vous avez install le logiciel de contr le de l onduleur vous pouvez alors v rifier qu il sauvegarde et ferme vos fichiers correctement puis teint londuleur automatiquement CITE 2 6 Indicateurs visuels et sonores
15. les batteries sont trop faibles ou hors d usage l ic ne Batterie faible 8 restera allum Eteindre Appuyer et maintenir enfonc le bouton d arr t 4 sur le panneau frontal pendant 3 secondes Si le bouton n est pas maintenu assez longtemps l onduleur ne s teindra pas NOTE Dans certains cas tels que surcharges courts circuits coupure ou puisement des batteries l onduleur s teindra de lui m me Il mettra alors des bips penadant 5 secondes avant de s arr ter D marrage Cet onduleur peut tre mis en marche m me sans secteur pr sent Il suffit pour cela de suivre la froid proc dure d crite au chapitre Allumer gt Red marrage automatique l onduleur red marrera automatiquement si le secteur redevient normal dans les 24 heures apr s un arr t automatique L ic ne de la batterie clignotera pendant toue cette p riode Si le secteur n est pas r tablit dans les 24 heures la fonction de red marrage automatiquement ne fonctionnera pas Un d marrage manuel sera alors n cessaire Pour emp cher un red marrage automatique il suffit d teindre l onduleur voir ci dessus 2 5 Simulation manuelle d une coupure de courant Pour tester l onduleur il suffit de le d brancher du secteur ou d utiliser la fonction auto test d crite pr c demment Si Ponduleur fonctionne continuellement il est recommand d effectuer ce test p riodiquement au moins une fois par semaine Pendant le test s assurer que
16. particular Si este equipo llegase a causar interferencia en la recepci n de radio y televisi n que puede ser determinado encendiendo y apagando el equipo el usuario puede corregir este problema siguiendo los siguientes pasos gt Reorientando o cambiando de lugar la antena receptora gt Aumentando la separaci n entre el equipo y el receptor gt Conecte el equipo a un toma corriente diferente al que se encuentra conectado el receptor gt Consulte a su distribuidor o a un t cnico experimentado de radio y televisi n A La segura y continua operaci n del UPS depende parcialmente del cuidado del usuario Por favor siga las siguientes precauciones No conecte el UPS en tomas corrientes que no sean de 2 polos 3 hilos con conexi n a tierra No coloque el UPS cerca de agua o en ambientes con humedad excesiva No permita que l quido o cualquier objeto extra o penetre al UPS No bloquee las rejillas de ventilaci n del UPS No coloque el UPS bajo los rayos del sol o cerca de fuentes de calor No conecte aparatos como secadores de pelo en los recept culos del UPS No desarme el UPS El terminal de alimentaci n debe ser instalado cerca del equipo Debe ser f cilmente aislable del AC comercial Para desconectar hale el conector del recept culo YY VU y y 1 Introducci n Caracter sticas El dise o de Sistema Online provee alta fiabilidad y eficiencia Controlado por procesador inteligente Panel de LCD amigab
17. 0 10 11 12135142 15 Avant l installation prenez quelques instants pour lire les conseils suivants gt Placement L onduleur doit tre plac dans un environnement prot g loin toute source de chaleur telle qu un radiateur Les lieux forte humidit sont galement viter gt Ventilation Pour un bon fonctionnement l onduleur doit tre correctement ventil Veillez laisser un espace d au moins 3 cm autour de l onduleur gt Charge des batteries Votre nouvel onduleur peut tre utilis d s r ception Toutefois une perte de charge peut se produire lors du transport et du stockage Il est donc recommand de charger les batteries pendant au moins 8 heures avant utilisation Pour cela il suffit de laisser l onduleur branch sur le secteur il se rechargera qu il soit allum ou teint Branchement au secteur Assurez vous que voltage et fr quences sont corrects Branchez l onduleur sur une prise murale 2 p les reli e la terre Assurez vous que la mise la terre fonctionne Evitez d utiliser des rallonges lectriques Si vous en utilisez assurez vous qu elles supportent 15 Amp res Connecter la charge Brancher vos appareils principaux ordinateur cran syst me de stockage sur les prises de sortie 16 Laissez votre appareil teint pour le moment Ne branchez pas d imprimante laser ou de photocopieur sur les sorties de votre ond
18. Manuel de l utilisateur Manual del usuario User s manual DELTA 800 1100 1400 2200 3000 Onduleur Online System 800 3000 VA SAI Online System 800 3000 VA 800 3000 VA Online System UPS SS UT EI SYSTEM WWW nn power com CE MANUEL CONTIENT D IMPORTANTES INFORMATIONS EN MATIERE DE SECURITE VEILLEZ A LE LIRE ENTIEREMENT AVANT DE COMMENCER SON INSTALLATION ET SON UTILISATION GARDEZ LE TOUJOURS A PORTEE DE MAIN POUR UNE UTILISATION ULTERIEURE A gt Afin d viter les risques de feu et d lectrocution Cet onduleur doit tre install l int rieur d un b timent a Ep temp rature contr l e loin de tout contaminant conducteur gt Risques d lectrocution Ne retirez pas le couvercle de l onduleur il ne contient aucune pi ce interchangeable Pour la maintenance faites appel un professionnel qualifi Risques d lectrocution en raison de la pr sence des batteries les fils lectriques pr sent l int rieur de onduleur ne sont pas rendus inertes par la coupure de l alimentation secteur Pour viter tout risque de choc lectrique d branchez votre onduleur de la prise murale et teignez le avant de manipuler les batteries ou de brancher le c ble d interface avec l ordinateur Ne jetez pas les batteries au feu Elles pourraient exploser Pour r duire les risques d incendie lors du remplacement des fusibles veillez ce qu ils aient exactement les m mes caract ristiques Les batteries utilis
19. S Then unplug it from the AC outlet to simulate a utility failure gt When utility failure occurs power is immediately supplied to your equipment from the UPS battery The alarm will beep once every 2 seconds and the Battery Mode icon will blink every five seconds reminding you that your equipment is running on a limited power source gt If the utility power is not restored the alarm will change to 1 beep every second alerting the user that the UPS will soon run out of battery power and will shut itself down gt During utility failure manually save and close the files you are currently working on and close your computer Then switch the UPS off to conserve the battery power for additional testing and usage gt Restore electrical power to connected equipment by re plugging the UPS power cord into a wall outlet P Backup all unsaved files before you perform the power outage simulation test 2 6 Audible Visual Indicators une Buzzer Operating Status x Normal mode Mains normal A Polarity Error ground fault x 1 beep every 2 seconds Battery mode Mains failure 1 beep every second Battery mode Mains failure imminent cutoff Battery low Stand by waiting for mains return for auto restart 2 x Continuous beep Overload short circuit or abnormal output voltage E A x Battery replacement needed E 7 A A Weak batte
20. Utilice un pa o suave y seco para limpiar el panel frontal y las partes pl sticas No utilice ning n detergente que contenga alcohol La vida esperada de las bater as es de 3 a os El mal uso y ambiente inapropiado reducir la vida til de las mismas Desconecte el UPS del AC comercial si no va a ser utilizado por un largo per odo de tiempo Cargue las bater as cada 3 meses para recuperar cualquier descarga que hayan sufrido si el UPS ha estado inactivo Cuando reemplace las bater as h galo con bater as del mismo tipo y modelo bater as de plomo cido selladas 14 4 2 Reemplazo de Baterias Cuando se encienda el icono de Reemplazo de Bateria puede que tenga que recargarla por lo menos durante 8 a 10 horas para ver si se apaga cuando la funci n de auto testeo se ejecute nuevamente Si el icono no cambia puede quitar los tornillos la tapa de la bater a intercambiable reemplace la bater a y pulse sobre el bot n de encendido para desactivar el icono Siga los pasos del 1 al 8 para reemplazar la nueva bater a 1 Use un destornillador de cruz para quitar los tornillos del panel frontal 2 Tire del panel frontal 3 Quite los cuatro tornillos como se indica arriba 4 Tire de la placa que asegura la bater a como se indica 5 Tire un poco de la bandeja de la bater a 6 Quite el polo negativo de la bater a y aseg rese de que no toque el polo positivo 7 Quite el polo positivo de la bater a y termin
21. as bater as contenidas en el UPS son reciclables El interior de las bater as es t xico y es una amenaza para el ambiente y la salud humana si no es desechado correctamente yy yy No abra o rompa las bater as Su interior es t xico y da ino para la piel y los ojos Una bater a puede representar un riesgo de descarga el ctrica y corriente de corto circuito Cuando sean reemplazadas remueva relojes anillos o cualquier otro objeto de metal de sus manos y utilice herramientas con manillas aisladas W y y Por favor anote la siguiente informaci n cuando llame o env e un correo electr nico 1 Modelo No Serial No 2 Fecha de compra 3 Descripci n completa del problema 15 6 Especificaciones T cnicas Modelo DELTA DELTA DELTA DELTA DELTA 800 1100 1400 2200 3000 Capacidad 800 VA 1100 VA 1400 VA 2200 VA 3000 VA Topologia Tipo Sistema online mono conversion Voltaje nominal 220 230 240 V Entrada Rango de voltaje 190 240V 198 250V 207 262V 5V Rango de frecuencia 50 60 Hz 3Hz Voltaje nominal 220 230 240 V 6V Salida Frecuencia 50 60 Hz 0 1 Forma de onda Senoidal perfecta Tiempo de transferencia lt 4 ms t pico Tipo Impermeable plomo cido sin mantenimiento Voltaje DC 12V 7Ah 12V 7Ah 12V 9Ah 12V 7Ah 12V 9Ah Bateria x2 x2 x2 x4 x4 Reemplazable por el usuario Yes Tiempo de recarga 2 4 horas
22. e alarm beeps continuously in backup mode UPS Fault including overload short circuit or output voltage and other abnormal conditions 1 Check output circuit 2 Call for service The site wiring fault icon is lit Site wiring problem Call an electrician to check your wiring UPS stays idle while AC is connected Power cord plug is loose Check the power cord plug Input breaker on rear panel blown or Input Fuse blown Reset the input breaker or replace fuse Wall socket is damaged Check wall socket with a table lamp During power failures the UPS automatic turns off Battery is not fully charged or battery is dead Recharge the battery for 4 hours and re test the backup time If problem remains replace batteries UPS is faulty Call for service 6 Sp cification Mod le DELTA 800 DELTA 1100 DELTA 1400 DELTA 2200 DELTA 3000 Puissance 800 VA 1100 VA 1400 VA 2200 VA 3000 VA Technologie Type On line system mono conversion Entr e Voltage Nominal 220 230 240 V Plage de Voltage 190 240V 198 250V 207 262V 5V Fr quence 50 60 Hz 3Hz Voltage Nominal 220 230 240 V 6V Fr quence 50 60 Hz 0 1 Sortie Forme d onde Sinuso dal v ritable os ms yeieal Type Plomb acide tanche sans maintenance DC Voltage 12V 7Ah x2 12V 7Ah
23. e contacter un service de maintenance veuillez rassembler les informations suivantes 1 Nom du mod le et num ro de s rie 2 Date d achat de l appareil 3 description compl te du probl me rencontr 2 Abnormal Situation Cause Solution UPS shutdowns immediately ON switch does not work and there is no alarm DIP Switch setting error Set correct Voltage and frequency on the DIP Switch 2 UPS can not be turned on and LCD panel does not light ON button 3 switch was not pressed or pressed less than 3 seconds Press and hold the Main On switch for more than 3 seconds Battery voltage is too low Recharge the battery for at least 4 hours Battery is not connected properly Check that battery connectors are fully engaged UPS is not connected to AC Power supply Check that the power cable from the UPS to the utility power supply is securely connected ON button 3 switch on front panel doesn t work Faulty microprocessor Unplug power cord and all connected equipment from the UPS to let it shut down automatically Replace PCB or microprocessor ON button 3 was damaged Replace ON button UPS input circuit breaker tripped Overload Remove some load by unplugging non critical equipment and press the circuit breaker 6 to reset it UPS starts up normally but there is no output Output breaker or output relay is damaged Check and Rep
24. e de tirar completamente la bandeja para reemplazar con la nueva bater a 8 Repita todo el procedimiento a la inversa para terminar con la tarea de reemplazo P Cuidado no intercambie los cables ROJO y NEGRO cuando los conecte al terminal de la bater a a Una vez que la bater a est desconectada las cargas no est n protegidas contra los cortes el ctricos 4 3 Instrucciones de Almacenamiento El UPS debe ser guardado en un lugar seco y fresco Aseg rese que la bater a este totalmente cargada antes de guardar el UPS Para guardar el UPS por largo tiempo en climas moderados cargue las bater as por 12 horas cada tres meses simplemente conectando el UPS y encendiendo el interruptor principal Repita cada dos meses si las temperaturas son altas 5 Problemas Comunes La tabla de Problemas Comunes que se muestra a continuaci n cubre la mayor a de las dificultades que usted puede encontrarse cuando el UPS este trabajando bajo condiciones normales Si el UPS no funciona adecuadamente por favor siga los siguientes pasos antes de llamar al centro de servicio 1 El UPS esta conectado a un toma corriente adecuado 2 El voltaje del toma corriente donde est conectado el UPS esta dentro del rango especificado 3 El fusible o el interruptor de circuito ambos del panel trasero necesitan ser reemplazados o reinicializados Por favor no abra la cubierta de metal No hay partes que puedan ser manejadas por el usuario L
25. e deshabilita Conexi n del fax MODEM L neas DSL Para proteger un fax MODEM Linea DSL conecte el cable de tel fono RJ11 de la toma de la pared al conector de entrada IN RJ45 RJ11 del UPS 1 Conecte el cable de tel fono de la toma de salida del UPS OUT RJ45 RJ11 1 al fax MODEM L nea DSL Conexi n de l neas de red Para proteger la red conecte el cable de red RJ45 del sistema de red a la toma IN RJ45 RJ11 del UPS 1 Conecte el cable de red de la toma de salida OUT RJ45 RJ11 del UPS 1 a la estaci n de red 2 4 Operaci n y Prueba de Funcionamiento gt Modo AC El UPS alimenta la carga a trav s del AC comercial manteniendo las baterfas totalmente cargadas Tambi n regula el voltaje de salida para que se mantenga en el rango requerido y a su vez aisla la carga de picos de corriente y ruido que pueda venir del AC comercial 3 Modo Bater a El UPS opera en este modo cuando el voltaje o la frecuencia de entrad han ca do fuera de los l mites permitidos Los usuarios son alertados de este hecho a trav s de indicadores visuales y alarmas El UPS alimenta la carga utilizando las bater as y el inversor mientras que el voltaje de salida sigue siendo regulado Funci n Panel Indicador Interruptor de Presione y mantenga presionado el Interruptor de encendido 3 en el panel frontal Espere hasta que la pantalla LCD se encienda y luego se apague Posteriormente suelte el Interruptor de encendido encendid
26. el AC comercial este desconectado Para evitar descargas el ctricas apague la unidad y descon ctela del toma corriente que proporciona el AC comercial antes de dar servicio a las bater as o conectar el cable de interfaz con la computadora PRECAUCION Al desechar las bater as no las lance al fuego porque estas podr an explotar Para disminuir el riesgo de incendio al reemplazar los fusibles utilicelos del mismo tipo y valor Las bater as de este UPS son reciclables El interior de las bater as es t xico y es una amenaza para el ambiente y la salud humana si no es desechado correctamente Por favor verifique las normas locales existentes para el desecho de materiales t xicos o retorne la bater a a un centro de servicio autorizado para su reemplazo o desecho Este UPS esta dise ado para que su instalaci n sea hecha en un ambiente controlado Refi rase a este manual para ver las condiciones ambientales recomendadas Aseg rese que durante la instalaci n de este equipo la suma de corrientes de fuga del UPS y las cargas conectadas no exceda los 3 5mA Aseg rese que las cargas est n apagadas durante la instalaci n VVV y y y Este equipo genera utiliza y puede irradiar energ a en el espectro de radio frecuencia Si no es instalado y utilizado siguiendo las instrucciones este equipo podr a causar interferencia a las comunicaciones por radio Sin embargo no hay garant a de que dicha interferencia no ocurra en una instalaci n
27. l SAI quedara sin energia y se apagara Durante el corte de energia el ctrica manualmente guarde los archivos sobre los cuales esta trabajando y apague el ordenador Despu s apague el SAI para conservar la bateria para su uso posterior y tests adicionales Reponga la energia el ctrica al equipo conectado reenchufando el SAI a la red el ctrica Respalde todos los archivos no guardados antes de realizar la simulaci n 2 6 Indicadores Audible Visuales LINE Alarma Estado operativo x Modo normal alimentaci n normal A Error de polaridad falla de toma de tierra x 1 pitido cada 2 segundos Modo bater a falla de alimentaci n E Modo bater a falla de alimentaci n apagado inminente A 5 1 pitido por segundo bateria baja _ _ _ i En stand by esperando que regrese la alimentaci n para el encendido automatico x Pitido continuo Sobrecarga corto circuito o salida de voltaje anormal x Necesita reemplazar la bater a Bateria d bil necesita recarga X ON A parpadeando OFF La alarma puede apagarse presionando el bot n de encendido durante aproximadamente 1 segundo en el P Modo Bater a A menos que haya otra alarma o que ocurra una condici n de falta la alarma permanecer en su condici n silenciada una vez que se apague sta 4 Servicio y Mantenimiento 4 1 y yy yyy Mantenimiento de rutina
28. lace output breaker or output relay UPS is always at battery mode Power cord is loose Re plug the power cord firmly Blown Input fuse or breaker Line voltage is too high or too low Line frequency is over range Remove load and replace fuse or resetting the input breaker with the same rating and check input voltage and frequency Input relay damaged Replace Input relay UPS is normal but the computer can t be turned on Computer input power cord is loose or not connected Reconnect computer input power cord correctly Backup time is less than the rating Battery is not fully charged or battery is dead or weak Recharge the battery for 4 hours and re test the backup time If problem remains Replace batteries UPS is slightly overloaded Remove the least critical load Communication function is not working Wrong interface cable Use the communication cable included in UPS box The replace battery icon 3 is lit Battery is weak Allow the battery to recharge for at least 4 hours Then perform a self test If the problem persists after recharging replace the battery Check that the battery connector is fully The overload icon O is lit and power output is normal UPS emits continuous beep and fault LED 2 is lit UPS is overloaded engaged Remove some load by unplugging non critical equipment The fault icon is lit and th
29. le Salida de onda senoidal pura F cil cambio de bater a en caliente RJ11 RJ45 Data Fax MODEM DSL Conexi n a red con protecci n de toma corriente Conexi n RS232 8 USB para software de manejo de potencia Encendido en fr o YY V YY yy 11 2 Instrucciones de Instalaci n 2 1 Desempaque e inspecci n Operaci n Examine la caja por da os aparentes Una vez que el UPS sea removido del empaque donde fue enviado se deben examinar todos los componentes que encuentre adentro por da os que pudieran haber ocurrido durante el env o Notifique a la compa a transportista si se observa cualquier da o La gt gt gt gt gt caja debe incluir lo siguiente 1 UPS 1 cable de entrada toma europea 1 cable de entrada toma inglesa 2 cables de salida IEC320 yyy y 1 Manual de usuario 1 cable telef nico RJ11 Guarde el empaque o des chelo apropiadamente 2 2 Vista General Panel frontal LED AC comercial 2 LED de falla Interruptor de encendido Interruptor de apagado LED de cambio de bater a LED de bater a de respaldo N A Bater a baja Bypass 0 Funci n Boost 1 Funci n Buck 2 Indicador de salida del UPS 3 Falla de polaridad o falla de tierra 4 Sobrecarga 5 Carga Nivel de bater a 6 Carga Bot n de control de indicaci n nivel de bater a Panel trasero 2 3 4 5 6 7 8 9 1 Puerto RJ45 Interruptor DIP Puerto de comunicaci n USB
30. ng Wrong interface cable Use the communication cable included in UPS box The replace battery icon SI is lit Battery is weak Allow the battery to recharge for at least 4 hours Then perform a self test If the problem persists after recharging replace the battery Battery Replacement connector is not connected properly Check that the battery connector is fully engaged The overload icon O is lit and power output is normal UPS emits continuous beep and fault LED 2 is lit UPS is overloaded Remove some load by unplugging non critical equipment The fault icon is lit and the alarm beeps continuously in backup mode UPS Fault including overload short circuit or output voltage and other abnormal conditions 1 Check output circuit 2 Call for service The site wiring fault icon is lit Site wiring problem Call an electrician to check your wiring UPS stays idle while AC is connected Power cord plug is loose Check the power cord plug Input breaker on rear panel blown or Input Fuse blown Reset the input breaker or replace fuse Wall socket is damaged Check wall socket with a table lamp During power failures the UPS automatic turns off Battery is not fully charged or battery is dead Recharge the battery for 4 hours and re test the backup time If problem remains replace batteries UPS is faulty Call for service
31. o El LED de modo de bater a amarillo se enciende y el UPS se encuentra ahora en modo de auto test Si el voltaje de alimentaci n es normal el UPS pasara a modo normal LED verde despu s que ha realizado su auto test Por otro lado si el voltaje de alimentaci n no es normal fall de voltaje el UPS pasara a modo bater a y sonara un zumbido cada dos segundos Test En condiciones normales de alimentaci n pulse el interruptor de encendido 3 por 3 segundos para ejecutar la funci n de Auto test de bater a Si la bater a esta normal entrara el Modo de Bater a por 10 segundos y luego regresara al Modo Normal Si el voltaje de bater a es mas bajo que el limite fijado el icono de Bater a Baja 8 parpadeara por 5 segundos y luego se apagara para cancelar el proceso de Auto test Por el contrario si la bateria esta debil o muerta el icono de Bater a Baja 8 permanecer encendido Apagado Pulse el interruptor de Apagado 4 por al menos 3 segundos para apagar el UPS Si presiona el interruptor menos de 3 segundos el UPS no se apagara NOTA En algunas ocasiones el UPS se apagara solo si hay sobrecarga la salida esta cortocircuitada o el punto de corte de la bater a alcanzo el Modo de respaldo Modo bater a El UPS autom ticamente cortara la salida y sonara por 5 segundos Luego se apagara completamente Encendido en Este UPS se puede encender aun cuando no hay AC presente fr o 13 gt
32. p Inspection Examine the packing carton for damage upon receipt Once the UPS has been removed from its shipping container everything inside the package should be inspected for damage that may have occurred while in transit Notify the carrier immediately if any damage is observed The box should include the following gt 1UPS gt 1 European input cable 1 UK input cable gt 2 output cables IEC320 gt 1 Users Manual gt 1 RJ11 telephone cable Retain the packing for future use or dispose of it properly 1 RJ45 Network cable 1 USB communication cable 1 RS232 communication cable 1 UPSILON 2000 software CD yyy y 2 2 Overview is 10 11 12135142 15 Front Panel po to 4 bi Utility LED Fault LED On Switch pl f Off Switch NE UBS LOAD Er m Battery Replacement LED ILI LI Battery Backup LED N A MITTE Battery Low Bypass Id 10 Utility Low UPS Boost i i bie od 11 Utility High UPS Buck 3 4 16 62 1 12 UPS Output Indicator 13 Polarity Error or Ground Fault 1 23 4 5 14 Overload i po po 15 Load Battery Level 16 Load Battery Level Indication control button VCONDAADN Rear panel 1 RJ11 RJ45 Port 2 DIP Switch 3 USB Communication Port 6 4 RS232 Communication Port 5 Internal CPU Reset Button press to shutdown 6 Output Breaker 7 8 9 1 Output sockets Outlet Rating Label Tell Input Fuse 0 Input socket Inlet
33. para 90 Protecci n de Modo normal gt 110 por 10 minutos y apagado sobrecarga Modo bateria gt 110 por segundos y apagado Protecci n de corto Modo normal Fusible de entrada y circuito electr nico circuito Modo bateria Circuito electr nico Comunicaci n Interfaz inteligente USB PNP amp RS232c auto switch Compatibilidad con sistemas operativos Windows 95 98Me XP NT 2000 2003 Linux FreeBSD Novell Netware Est ndar de seguridad EN50091 1 Seguridad EMC EN50091 2 Marca CE Temperatura 0 40 C Humedad 0 95 humedad no condensable Ambiental Dimensiones profundidad ancho alto 173x247x369 173x247x472 Peso neto 14 7 kg 15 kg 16 kg 23 kg 25 kg 16 Important Safety Instructions THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS PLEASE READ THIS MANUAL THOROUGHLY BEFORE ATTEMPTING TO INSTALL OR OPERATE THE UPS KEEP IT HANDY FOR FUTURE REFERENCE A gt To prevent the risk of fire or electrical shock install in a temperature and humidity controlled indoor area free of conductive contaminants gt Risk of electrical shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Risk of electrical shock Hazardous live components inside this UPS are energized from the battery supply even when the input AC power is disconnected To avoid electrical shock turn off the unit and unplug it from the wall
34. ry recharge needed X ON A Blinking OFF The Alarm may be turned off by pushing the On Switch for approximately 1 second in the Battery Mode P Unless any other warning or fault condition occurs the alarm remains at Silence condition once the Alarm Silence is turned off 4 Service and Maintenance 4 1 Routine Maintenance Use dry soft cloths to clean the front panel and plastic parts Do not use any detergent that contains alcoholic ingredient The expected lifetime of the battery is around 3 years Improper operation or harsh environment will reduce the actual lifetime Unplug the UPS from power inlet if the UPS will not operate for a long period of time Charge the battery every 3 months to recover the self discharge capacity when the UPS is in extended storage When replacing batteries use the sealed lead acid maintenance free battery with the same number and capacity yyy vey Battery Replacement Overview When the Battery Replacement icon lights up you may leave the UPS to be re charged for at least 8 10 hours to see whether it turns off after Self test Function is executed again If the icon remains unchanged you may unscrew the Easy Swappable Battery cover replace the battery then push the On Switch to disable the icon 20 Please follow the steps 1 8 to replace the new battery 9 Use cross screw driver to remove the screws of the front panel 10 Pull the front panel out from
35. s proper battery charge It also regulates the output voltage within a narrow range and serves to isolate the load from surges and electrical noise brought by the mains gt On Battery Mode The UPS operates on battery when the line voltage or frequency has fallen outside the limits The user is alerted of this mode of operation by visual and audible indicators The UPS provides power to the load from the battery and through its inverter and the output voltage and frequency of the UPS are regulated within a narrow band Function Panel Indicator Switch On Press and hold the ON switch 3 on the front panel Wait until the LCD display is lit then extinguished Then release the ON switch The battery mode LED Amber lights up and the UPS is now under self test mode If utility power is normal the UPS will switch to normal mode Green LED after its self test is completed On the other hand if utility power is not normal power failure the UPS will switch to battery mode and the buzzer will sound every 2 seconds Test Under normal utility condition push the On Switch 3 for 3 seconds to execute the Battery Self test function If the battery is normal it will enter Battery Mode for 10 seconds then return back to Normal Mode If the battery voltage is lower than set limit the Battery Low icon 8 will blink for 5 seconds then extinguish to stop self test procedure And if battery is weak or dead Battery Low icon 8 will stay lit Switch Off
36. the UPS 11 Remove the 4 screws as indicated above 12 Pull down the battery fastened plate as indicated 13 Pull out the battery tray a little 14 Remove the battery negative end of the battery and make sure it won t be short with the battery positive 15 Remove the battery positive end and then pull out the battery tray completely for new battery replacement 16 Repeat all the procedures in reverse way to finish the replacement task Please do not be reversed the RED and black of battery wire when you connect them to the terminal of a battery Once the battery is disconnected the loads are not protected from power outages 4 2 Storage Instructions The UPS should be stored in a cool dry location Make sure the battery is fully charged before the UPS is stored For extended storage in moderate climates the battery should be charged for 12 hours every 6 months by plugging the power cord into the wall receptacle and turning on the main switch Repeat every 3 months in high temperature locations more than 30 C 5 Troubleshooting The TROUBLESHOOTING TABLE in the next page covers most of the difficulties that you may encounter under normal working conditions If the UPS fails to operate properly please review the following steps before calling the repair center 1 Is the UPS plugged into a proper working outlet 2 Is the line voltage within the specified rating 3 Does the fuse on the rear panel need to
37. the separation between the equipment and the receiver gt Connect the equipment into an outlet on a circuit different from that to which the receiver is connected gt Consult the dealer or an experienced Radio TV technician for help A Safe and continuous operation of the UPS depends partially on the care taken by users Please observe the following precautions Do not attempt to power the UPS from any receptacle except a 2 pole 3 wire grounded receptacle Do not place the UPS near water or in environments of excessive humidity Do not allow liquid or any foreign objects to get inside the UPS Do not block air vents in front of the UPS or air exhausts on the back Do not place the UPS under direct sunshine or close to heat emitting sources Do not plug appliances such as hair dryers into the UPS receptacles Do not disassemble the UPS The power socket should be installed near the equipment It should be easily accessible to isolate it from AC input To disconnect pull the plug from the receptacle YY YY VU y y 1 Introduction Features Online System Design Provides High Reliability and Efficiency Intelligent Microprocessor Control User friendly LCD panel Pure Sine Wave Output Easy battery hot swap RJ11 RJ45 Data Fax Modem DSL Network Connection Surge Protection RS232 amp USB connection for Power Management Software Cold start YY YY VU yy 17 2 Installation and Operating Instruction 2 1 Unpacking am
38. the utility power supply is securely connected ON button 3 switch on front panel doesn t work Faulty microprocessor Unplug power cord and all connected equipment from the UPS to let it shut down automatically Replace PCB or microprocessor ON button 3 was damaged Replace ON button UPS input circuit breaker tripped Overload Remove some load by unplugging non critical equipment and press the circuit breaker 6 to reset it UPS starts up normally but there is no output Output breaker or output relay is damaged Check and Replace output breaker or output relay UPS is always at battery mode Power cord is loose Re plug the power cord firmly Blown Input fuse or breaker Line voltage is too high or too low Line frequency is over range Remove load and replace fuse or resetting the input breaker with the same rating and check input voltage and frequency Input relay damaged Replace Input relay UPS is normal but the computer can t be turned on Computer input power cord is loose or not connected Reconnect computer input power cord correctly Backup time is less than the rating Battery is not fully charged or battery is dead or weak Recharge the battery for 4 hours and re test the backup time If problem remains Replace batteries UPS is slightly overloaded Remove the least critical load Communication function is not worki
39. tiellement du soin pris par l utilisateur Veuillez observer les pr cautions suivantes N essayez pas d alimenter l onduleur autrement qu l aide d une prise 2 p les reli e la terre Ne pas placer l onduleur pr s de l eau ou dans un environnement trop humide Ne laisser aucun liquide ou objet tranger p n trer l int rieur de l onduleur Ne bloquez pas les ouvertures de ventilation de l onduleur Ne placez pas l onduleur sous les rayons directs du soleil ou pr s d une source de chaleur Ne branchez pas d appareils tels qu un s che cheveux sur les prises de l onduleur Ne demontez pas l onduleur La prise d alimentation de l onduleur doit tre proche et facile d acc s afin de permettre de la d brancher facilement du secteur VU y y 1 Introduction Caract ristiques YY VU Y y Technologie On line System fiabilit et efficacit Contr le par microprocesseur Forme d onde sinusoidale v ritable Protection RJ11 RJ45 ligne t l phonique r seau prot g e Changement facile des batteries D marrage froid Connexion RS232 USB communication avec un ordinateur 2 installation et mise en service 2 1 D ballage et inspection D s r ception v rifiez que votre onduleur na pas t endommag Inspectez la totalit du mat riel contenu dans l emballage V rifiez que l emballage carton n est pas endommag lors de la r ception Une foi l onduleur retir de son emballage v rifie
40. tos Conecte el UPS a una toma 2 corriente de 2 polos 3 hilos con conexi n a tierra Aseg rese de que la toma en la pared est protegida por un fusible interruptor en el tablero el ctrico correspondiente Evite utilizar extensiones de hacerlo aseg rese que soporten 15 Amp Para las versiones 220 230 240 utilice el cable de entrada suministrado IEC hembra toma Europea inglesa para conectar el UPS 10 al AC comercial No conecte al UPS impresoras l ser o fotocopiadoras debido a que la demanda de corriente de estos equipos son mucho m s altas que la de los equipos perif ricos normales Fijaci n de voltaje y frecuencia FUNCTION 3 2 1 NO did El voltaje 220 230 240 Vac amp frecuencia 50 VOLTAGE 220V tli 60 Hz del UPS debe ser fijado a trav s de un VOLTAGE 230V TE cl switch en el panel trasero del UPS Use la tabla a VOLTAGE 240V 4 la derecha para fijar el voltaje y la frecuencia del FREQUENCY 50 Hz 4 UPS de acuerdo a sus requerimientos FREQUENCY 60 Hz y Conexi n de la Carga Conecte el primer equipo en uno de los recept culos protegidos por bater a del UPS ejemplo ordenador monitor etc No encienda los equipos todav a Conexi n del Ordenador Use el cable RS 232 o cable USB incluidos Conecte un extremo al UPS 2 3 y el otro en el Puerto apropiado del ordenador Una vez un puerto esta habilitado el otro autom ticamente s
41. uleur La puissance n cessaire ces appareils est bien sup rieure la moyenne R glage de la fr quence et du voltage Le voltage 220 230 240 et la fr quence 50 60 FUNCTION 31217 O did Hz de cet onduleur doivent tre r gl s l aide du VOLTAGE 220V tA eZ I bo tier double rang e de connexion DIP se VOLTAGE 230V MN trouvant l arri re de l onduleur Utiliser le sch ma VOLTAGE 240V lt situ droite pour r gler fr quence et voltage selon EREQUENCY 50 Hz 1 vos besoins FREQUENCY 60 Hz Branchement l ordinateur Utilisez le c ble RS 232 ou USB inclus Branchez un extr mit sur l onduleur 2 3 et l autre sur un port libre de votre ordinateur Lorsqu un port de sortie est utilis l autre est automatiquement d sactiv Protection de la ligne tel fax modem DSL Branchez le c ble de t l phone type RJ11 issu de la prise murale sur la prise RJ11 RJ45 IN de Ponduleur 1 Branchez ensuite le c ble fourni entre la prise RJ11 RJ45 OUT de l onduleur 1 et votre et votre t l phone fax ou modem Protection du r seau Branchez le c ble r seau type RJ145 issu de la prise murale sur la prise RJ11 RJ45 IN de l onduleur 1 Branchez ensuite le c ble fourni entre la prise RJ11 RJ45 OUT de l onduleur 1 et votre et votre r seau 2 4 Utilisation et test de fonctionnement
42. x2 12V 9Ah x2 12V 7Ah x4 12V 9Ah x4 Batterie Replacement utilisateur Qui Temps de recharge 2 4 heures 90 Prot contre les Mode Normal gt 110 pendant 10 minutes puis arr t surcharges Mode Batterie gt 110 pendant 10 secondes puis arr t Prot contre les Mode Normal Fusible en entr e amp circuit lectronique courts circuits Mode Batterie Circuit lectronique Interface USB PNP amp RS232c auto s lection Communication Syst mes Windows 95 98Me XP NT 2000 2003 Linux FreeBSD Novell Compatibles Standard EN50091 1 S curit EMC EN50091 2 Marquage CE Temp rature 0 40 C Environnement Humidit 0 95 R Humidit R Non condensante Dimension D W H 173x247x369 173x247x472 Poids Net 14 7 kg 15 kg 16 kg 23 kg 25 kg 10 IMPORTANTE Instrucciones de Seguridad ESTE MANUAL CONTIENE INSTRUCCIONES DE SEGURIDAD IMPORTANTES POR FAVOR LEALO CUIDADOSAMENTE ANTES DE INSTALAR U OPERAR EL UPS MANTENGALO A MANO PARA REFERENCIAS FUTURAS A gt Para prevenir riesgos de descarga el ctrica y fuego instale el UPS en un area cerrada con temperatura controlada y libre de agentes conductores 3 Riesgo de descarga el ctrica No intente desarmar la unidad ya que la misma contiene partes que no pueden ser manejadas por los usuarios S lo el personal de Servicio T cnico esta capacitado para realizar reparaciones PRECAUCION Partes el ctricas internas pueden estar energizadas por la bater a a n cuando
43. z que tout le contenu du carton n as pas t endommag lors du transport Notifiez imm diatement tout dommage constat aupr s du transporteur Le contenu de l emballage doit tre le suivant gt 1 onduleur gt 1 cordon d alimentation d entr e schucko IEC gt 1 cordon d alimentation d entr e UK IEC gt 2 cordons d alimentation de sortie IEC IEC gt 1 Manuel utilisateur gt 1 c ble RJ11 de connexion de ligne t l phonique Conserver l emballage pour un usage ult rieur 2 2 Vue d ensemble Panneau frontal 1 Voyant secteur 2 Voyant d faut 3 Mise en marche 4 Arr t 5 Ic ne de remplacement des batteries 6 Ic ne de Mode Onduleur 7 N A 8 Batteries faibles LOW 9 By pass 10 Voltage secteur trop faible corrig 11 Voltage secteur trop fort corrig 12 Sortie onduleur 13 Erreur de polarit ou de mise la terre 14 Surcharge 15 Taux de charge de l onduleur des batteries yyy y 16 Affichage taux de charge de l onduleur des batteries Panneau arri re 1 Port RJ11 RJ45 2 DIP bo tier double rang e de connexion 3 Port de Communication USB 4 Port de Communication RS232 5 Remise z ro du processeur 6 Disjoncteur de sortie 7 Sorties lectriques 8 Identification 9 Fusible d entr e 10 Prise d entr e secteur 2 3 Installation 1 cable RJ45 de connexion au r seau 1 cable USB de communication 1 cable RS232 de communication 1 CD du logiciel UPSILON 200