1. UY pe i LS H Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apagachispas J Culatazo el Principio Us para comenzar motor manualmente K Depurador de Aire Filtra el aire de entrada a medida que penetra en el motor L Palanca del Cebador Usada cuando se est dando arranque a un motor fr o M V lvula de Combustible Permite abrir y cerrar la alimentaci n de combustible al motor N Tanque del Combustible El tanque tiene una capacidad de 15 14 litros 4 galones de gasolina sin contenido de plomo No mostrado Identificaci n del Motor Indica el modelo tipo y c digo del motor Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda Etiqueta de Identificaci n Proporciona el modelo revisi n y el n mero de serie de generador Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda BRIGGSandSTRATTON COM Juegos de cordones y enchufes conectores Utilice nicamente cables prolongadores de alta calidad bien aislados y conectados a tierra con las tomas del generador Examine los cables prolongadores antes de cada uso Examine los valores nominales de los cables prolongadores antes de utilizarlos Consulte los manuales del operario de dispositivos a los que se les suministra energ a para conocer las recomendaciones del fabricante A ADVERTENCIA Los
2. BRIGGSSSTRATION Portable Generator Operator s Manual This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and generators and PGMA Portable Generator Manufacturers Association standard PGMA G200 Standard for Testing and Validating Performance of Portable Generators BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Manual No 80008045 Revision A Thank you for purchasing this quality built Briggs Stratton generator We are pleased that you ve placed your confidence in the Briggs amp Stratton brand When operated and maintained according to the instructions in this manual your Briggs amp Stratton generator will provide many years of dependable service This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save this original manual for future reference This generator requires final assembly before use Refer to the Assembly section of this manual for instructions on final assembly procedures Follow the instructions completely
3. Where to Find Us You never have to look far to find Briggs Stratton support and service for your generator Consult your Yellow Pages There are over 30 000 Briggs amp Stratton authorized service dealers worldwide who provide quality service You can also contact Briggs Stratton Customer Service by phone at 800 743 4115 or on the Internet at BRIGGSandSTRATTON COM Generator Engine Model Number Model Number Revision Type Number Serial Number Code Number Date Purchased Table of Contents Safe Operation Checklist 3 Operator Sa fety 4n 4 Assembly IT 9 Features and Controls 14 Operation 16 Maintenance 19 Troubleshooting 24 VU TASSE eo ens hee ee cake eee ee 25 Product Specifications 26 Common Service Parts 26 Copyright 2014 Briggs amp Stratton Power Products Group LLC Milwaukee WI USA All rights reserved BRIGGS amp STRATTON POWER PRODUCTS is a registered trademark of Briggs amp Stratton Corporation Milwaukee WI USA 2 BRIGGSandSTRATTON COM Safe Operation Checklist Safe operation of the portable generator requires the completion of the following tasks Carbon Monoxide CO Alarm O Carbon monoxide CO alarm s in working order Smoke Alarm O Smoke alarm s in working order Generator Location O Generator placed i
4. DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator BRIGGSandSTRATTON COM Portable Generator Location Before starting the portable generator there are two equally important safety concerns regarding carbon monoxide CO poisoning and fire that must be addressed NOTICE Satisfying the RISK OF CARBON MONOXIDE POISONING location requirements may not satisfy the fire location requirements Satisfying the RISK OF FIRE location requirements may not satisfy the CARBON MONOXIDE POISONING location requirements Operation Location of Portable Generator to REDUCE THE RISK OF CARBON MONOXIDE POISONING All fossil fuel burning equipment such as a portable generator contains carbon monoxide CO gas in the engine exhaust a poisonous gas that could kill you in minutes You CANNOT smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas The following must be completed prior to starting the portable generator engine A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you c
5. Engine has lost compression Load is too high Dirty air filter Clogged or dirty fuel filter Carburetor is running too rich or too lean Clogged or dirty fuel filter Correction Reset circuit breaker Contact authorized service facility Check and repair Connect another device that is in good condition Disconnect shorted electrical load Contact authorized service facility See Don t Overload Generator Contact authorized service facility Clean or replace fuel filter Set rocker switch to ON 1 position Turn fuel valve to ON I position Fill crankcase to proper level or place generator on level surface Clean or replace air cleaner Clogged or dirty fuel filter Fill fuel tank Drain fuel tank and carburetor fill with fresh fuel Connect wire to spark plug Replace spark plug Drain gas tank and carburetor fill with fresh fuel Wait 5 minutes and re crank engine Contact autho rized service facility Contact authorized service facility Contact authorized service facility See Don t Overload Generator Replace air filter Clean or replace fuel filter Contact authorized service facility Clean or replace fuel filter 24 BRIGGSandSTRATTON COM BRIGGS amp STRATTON PRODUCTS WARRANTY POLICY January 2014 LIMITED WARRANTY Briggs amp Stratton warrants that during the warranty period sp
6. NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattage Reference Guide Running Additional Starting Surge Watts Tool or Appliance Furnace Fan Blower 1 2 H att P 2350 1300 Refrigerator Freezer 2200 W 1 2 HP W 000 BTU ener P 1 4 in 2100 7 80 80 70 100 5 0 7 O1 120 3600 Humidifier 13 Gal 175 Central AC 24 000 BTU 38 11400 O O D lt O O lt O 5 mb O O O Microwave Oven 1000 Watt 100 N a O OIO O mb oO O T p a P e V Color Television 27 in S O te r W S Personal Computer w 17 in 8 monitor Other oo o a7 DIVHob Site 100 140 180 1800 Table Saw Radial Arm 2000 Saw 10 in Air C 1 HP 1600 4500 Wattages listed are approximate only Check tool or appliance for actual wattage O1 O1 O O 2350 11700 se O O 5 0 0 0 0 0 0 0 0 0 0 0 5 0 Li u H El D C t e D h m t a n f C D R C r Y C 2300 1800 1800 2000 0 0 0 0 0 0 0 t Bulb p Pum er Well ting Co dow AC fee Mak tric Sto Family Room CD Pl reo Rec urity Sy age Do Job Si ular Sa ompre g 5w 1 3 ump e oling 10 O r e e 8 Element V yer iver tem a r Op I i 7 sor BRIGGSandSTRATTON COM Maintenance Maintenance Schedule Follow the hourly
7. NOTICE improper treatment of generator could damage it and shorten its life e DO NOT expose generator to excessive moisture dust dirt or Corrosive vapors e DO NOT insert any objects through cooling slots e Use a soft bristle brush to loosen caked on dirt or Oil e Use a vacuum cleaner to pick up loose dirt and debris 19 Fuel Valve Maintenance The fuel valve is equipped with a fuel sediment cup screen and o ring that need to be cleaned 1 Move fuel valve to OFF 0 position 2 Remove sediment cup A from fuel valve Remove o ring B and screen C from fuel valve 3 Wash sediment cup o ring and screen in a nonflammable solvent Dry them thoroughly 4 Place screen and o ring into fuel valve Install sediment cup and tighten securely 5 Move fuel valve to ON I position and check for leaks Replace fuel valve if there is any leakage Engine Maintenance WARNING Unintentional sparking could cause fire or electric shock resulting in l AA AN death or serious injury WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR e Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK e Use approved spark plug tester e DO NOT check for spark with spark plug removed 20 Oil Oil Recommendations We recommend the use of Briggs amp Stratton Warranty Certified oils for best performance Other high quality det
8. CARBONO Ubicaci n de operaci n del generador port til para REDUCIR EL RIESGO DE ENVENENAMIENTO POR MONOXIDO DE CARBONO Todo equipo que quema combustible f sil como un generador port til contiene gas mon xido de carbono CO en el escape del motor un gas venenoso que podr a matarlo en minutos NO tiene olor color ni sabor Aunque no pueda oler los vapores del escape podr a estar expuesto al gas mon xido de carbono Lo siguiente debe completarse antes de arrancar el motor del generador port til A PELIGRO El uso de un generador en un espacio interior PUEDE PROVOCAR LA MUERTE EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono un veneno invisible e inodoro NUNCA utilice un generador Utilicelo solo en el en el interior de una casa o EXTERIOR alejado de un garaje AUNQUE haya ventanas puertas y ventanas y puertas abiertas aberturas de ventilaci n e En muchos estados por ley es necesario que en los hogares se cuente con una alarma A de mon xido de carbono CO en funcionamiento Instale mantenga alarmas de mon xido de carbono de bater as o enchufables con respaldo de bater a de acuerdo con las instrucciones del fabricante Una alarma de CO es un dispositivo electr nico que detecta niveles peligrosos de CO Cuando hay acumulaci n de CO la alarma alerta a los ocupantes con una luz indicadora visual centellante y una alarma Las alarmas de humo no pueden detectar
9. and two M8 hex nuts K Tighten with a 13 mm socket wrench and 13 mm wrench U Add Engine Oil 1 Place generator on a flat level surface 2 Clean area around oil fill and remove yellow oil fill cap 3 Using oil funnel optional slowly pour contents of provided oil bottle into oil fill opening NOTICE improper treatment of generator could damage it and shorten its life e DO NOT attempt to crank or start the engine before it has been properly serviced with the recommended oil This could result in an engine failure 4 Replace oil fill cap and fully tighten Add Fuel Fuel must meet these requirements e Clean fresh unleaded gasoline e A minimum of 87 octane 87 AKI 91 RON For high altitude use see High Altitude e Gasoline with up to 10 ethanol gasohol is acceptable NOTICE Use of unapproved fuels could damage generator and voids warranty e DO NOT use unapproved gasoline such as E15 and E85 e DO NOT mix oil in gasoline or modify engine to run on alternate fuels To protect the fuel system from gum formation mix in a fuel stabilizer when adding fuel See Storage All fuel is not the same If you experience starting or performance problems after using fuel switch to a different fuel provider or change brands This engine is certified to operate on gasoline The emission control system for this engine is EM Engine Modifications WARNING Fuel and its vapors are extremely flammable a
10. de combustible vac o o con la v lvula para apagar el combustible posici n OFF 0 e NO incline el motor o el equipo de tal manera que la combustible se pueda derramar e Desconecte el cable de la buj a CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE e Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible ADVERTENCIA e Este generador no cumple la norma 33CFR 183 del cuerpo de guardacostas de EE UU y no debe utilizarse en aplicaciones marinas e El uso de un generador no homologado por cuerpo de guardacostas de EE UU puede provocar lesiones Espa ol ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales combustibles y las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El contacto con la zona del silenciador podr a producir quemaduras y lesiones graves NO toque las superficies calientes y EVITE los gases del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior Utilizar el motor en un terreno boscoso con maleza o cubierto de hierba constituye una infracci n al C digo de recursos p blicos de Califo
11. para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n Compruebe frecuentemente que las l neas de combustible el tanque el tap n y los accesorios no est n rotos o tengan fugas C mbielos si es necesario NO encienda un cigarrillo o fume 1 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 2 A ada lentamente gasolina sin plomo A al tanque de combustible B Tenga cuidado de que el nivel de combustible no rebase el l mite C Esto permite dejar el espacio adecuado para que el combustible se expanda como se muestra PR Sa N A g SSSA So LN SAN N gt SSI RS SOW PR 7 TT TE SN On Or 3 Instale la tapa del tanque de combustible y la espera para alg n combustible rociado para evaporar 10 Gran altitud En altitudes superiores a 1 524 metros 5 000 pies se deber utilizar gasolina con un m nimo de 85 octanos 85 AKI 89 RON Para seguir cumpliendo la normativa sobre emisiones es necesario ajustar la unidad para su uso a gran altitud De no realizarse este ajuste el rendimiento se reducir y el consumo de combustible y las emisiones aumentar n Para obtener m s informaci n sobre el ajuste para gran altitud consulte con un distribuidor cualificado de Briggs 4 Stratton No se recomienda utilizar el
12. section Every effort has been made to ensure that the information in this manual is both accurate and current However the manufacturer reserves the right to change alter or otherwise improve the generator and this documentation at any time without prior notice The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency and the California Air Resources Board Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others You must also make sure that the procedure work method or operating technique that you choose does not render the generator unsafe Safety Symbols and Meanings gt Toxic Fumes Kickback Electrical Shock Fire Explosion Operator s Manual Moving Parts Flying Objects Hot Surface The safety alert symbol indicates a potential personal injury hazard A signal word DANGER WARNING or CAUTION is used with the alert symbol to designate a degree or level of hazard seriousness A safety symbol may be used to represent the type of hazard The signal word NOTICE is used to address practices not related t
13. UU Guarde el recibo comprobante de compra Si no se proporciona una prueba de la fecha de compra inicial en el momento se solicitar servicio de garant a se utilizar la fecha de fabricaci n del producto para determinar el per odo de garant a No es necesario el registro del producto para obtener el servicio de garant a de los productos Briggs amp Stratton ACERCA DE LA GARANTIA El servicio de garantia solo esta disponible a trav s de los distribuidores de servicio autorizados de Briggs amp Stratton La mayor parte de las reparaciones bajo garantia se atienden de manera rutinaria pero algunas veces las solicitudes de reparaciones bajo garantia podrian no ser apropiadas Esta garantia SOLO cubre defectos en materiales y mano de obra No cubre los da os ocasionados por un uso incorrecto o un mal uso un mantenimiento o unas reparaciones inadecuadas el desgaste y la rotura propios del uso o bien el uso de un combustible en mal estado o no aprobado Uso no adecuado y mal uso el uso correcto y para el que se ha dise ado este equipo se describe en el manual del usuario Si el producto no se usa de la manera que se describe en el manual del usuario o si el producto se usa despu s de que haya resultado da ado quedar anulada la garant a La garant a queda anulada si se ha borrado el n mero de serie del producto o el producto ha sido modificado de alguna manera o si el producto presenta indicios de haber sido usado incorrectamente por e
14. Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 20 Amps o mayores Protecci n contra fallos de conexi n a tierra Las tomas dobles disponen de protecci n GFCI interruptor de circuito de fallo de conexi n a tierra Este dispositivo cumple las normativas federal nacional y local vigentes La toma para remolques del generador no est protegida por un GFCI El GFCI protege contra las descargas el ctricas que se pueden producir cuando un cuerpo humano se convierte en el medio a trav s del cual la electricidad llega a tierra Este fen meno puede producirse cuando el usuario toca un aparato o un cable con corriente una ca er a u otro material conectado a tierra Con la protecci n de un GFCI el usuario puede sentir la descarga pero el dispositivo corta la corriente lo bastante r pido como para que una persona con una salud normal no sufra ning n da o de gravedad ADVERTENCIA El voltaje del generador podr a provocar descargas el ctricas o quemaduras que pueden producir lesiones graves o la muerte e El contacto simult neo con el conductor caliente y neutro puede provocar descargas el ctricas y quemaduras incluso si el GFCI del circuito est protegido e SIEMPRE que vaya a utilizar la toma del GFCI pulse antes el bot n de prueba para comprobar que funciona Comprobaci n del GFCI Pruebe el enchufe del GFCI antes de cada uso como se indica a continuaci n e Pulse el
15. Volt AC 30 Amp Travai heuer Receptacle 2 4 kW at 20 Amps of current Use cord sets that are Use a NEMA TT 30 plug with this receptacle Connect rated for 125 Volt AC loads at 20 Amps or greater a 3 wire travel trailer cord set rated for 125 Volt AC Ground Fault Protection loads at 30 Amps to the plug i iin The duplex receptacle is equipped with Ground Fault Circuit Interrupter GFCI protection This device NEMA TT 30 Ground Green meets applicable federal state and local codes The generator s travel trailer receptacle is not protected by a Ground Fault Circuit Interrupter GFCI The GFCI protects against electrical shock that may be caused if your body becomes a path which electricity travels to reach ground This could happen if you touch a Live appliance or wire or are touching plumbing or other materials that connect to the ground When protected by a GFCI one may still feel a shock but the GFCI should cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury Neutral Use this receptacle to operate 120 Volt AC 60 Hz A WARNING Generator voltage could cause single phase travel trailer loads requiring up to electrical shock or burn resulting in death or 3 500 watts 3 5 kW of power at 29 16 Amps The serious injury outlet is protected by a push to reset circuit breaker e Contact with the hot and neutral conductor at the same time can cause electrical shoc
16. autorizado m s cercano en el mapa localizador de distribuidores en BRIGGSandSTATTON COM El comprador debe ponerse en contacto con el distribuidor autorizado y poner el producto a disposici n del mismo para que lo inspeccione y lo pruebe No existe otra garant a expresa Las garant as impl citas inclusive aquellas de comerciabilidad y de idoneidad para un prop sito en particular se limitan al per odo de garant a expresado abajo o hasta los l mites permitidos por la ley La responsabilidad por da os fortuitos o indirectos est excluida en tanto lo permita la ley Algunos pa ses o estados no permiten limitar la duraci n de una garant a impl cita ni excluir o limitar los da os secundarios y derivados Por tanto es posible que las limitaciones y exclusiones mencionadas no sean aplicables en su caso Esta garant a le otorga derechos legales espec ficos y tambi n podr a tener otros que var an seg n el estado o el pa s PER ODO DE GARANT A Art culo Uso particular Uso comercial Equipo 24 meses A 12 meses Motor 24 meses 12 meses Bater a si est instalada 3 meses Ninguno A Despu s de 12 meses la garant a nicamente cubre las partes Se aplica nicamente a los motores Briggs amp Stratton La cobertura de la garant a de los motores que no sean Briggs amp Stratton es proporcionada por el fabricante del motor La declaraci n de garant a de emisiones cubre los comentarios relacionados con las emisiones En Aust
17. bot n Test Prueba El bot n Reset Rearme deber a saltar e impedir as que el enchufe reciba alimentaci n el ctrica Utilice una l mpara de prueba en cada enchufe para comprobarlo e Si la prueba del GFCI es satisfactoria restablezca la alimentaci n presionando firmemente el bot n Reset hasta el fondo de forma que quede sujeto Si el enchufe GFCI no se rearma correctamente no lo utilice Llame o lleve el generador a un centro local de servicio e Si el GFCI salta por s solo en cualquier momento re rmelo y pruebe el enchufe Si el bot n de rearme no salta al pulsar el bot n de prueba no utilice el enchufe Llame o lleve el generador a un centro local de servicio Espa ol 15 Operando Encienda el motor Desconecte todas las cargas el ctricas del generador Use las siguientes instrucciones para encender 1 Aseg rese de que la unidad est en una superficie plana AVISO Si la unidad no se arranca y utiliza en una superficie plana se pueden producir problemas de arranque y de parada durante el funcionamiento 2 Gire la v lvula del combustible A a la ON 1 posici n 3 Mueva la palanca estranguladora B hasta la posici n CHOKE x 4 Sit e el interruptor balanc n C en la ON I posici n 5 Hale la manija de retroceso en forma suave hasta que sienta resistencia Luego para arrancar el motor hacer tracci n en forma r pida una sola vez e Si el motor
18. de evitar la retroalimentaci n ya que se a sla el generador de las personas que trabajan con el suministro el ctrico Si utiliza el generador como sistema de reserva notif quelo a la compa a el ctrica Use un interruptor para la falla del circuito de tierra G FCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o da ados de cualquier forma NO opere el generador bajo la lluvia NO maneje el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador BRIGGSandSTRATTON COM Ubicaci n del generador port til Antes de arrancar el generador port til hay dos consideraciones de seguridad que deben atenderse que tienen igual importancia respecto al envenenamiento por mon xido de carbono CO y a los incendios AVISO Cumplir con los requisitos de ubicaci n relacionados con el RIESGO DE ENVENENAMIENTO POR MON XIDO DE CARBONO podr a no cumplir con los requisitos de ubicaci n para evitar incendios Cumplir con los requisitos de ubicaci n relacionados con el RIESGO DE INCENDIOS podr a no cumplir con los requisitos de ubicaci n para evitar ENVENENAMIENTO POR MON XIDO DE
19. land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws Contact the original equipment manufacturer retailer or dealer to obtain a spark arrester designed for the exhaust system installed on this engine Replacement parts must be the same and installed in the same position as the original parts A Unintentional sparking could cause A se or electric shock resulting in death or serious injury As OR MAKING REPAIRS TO YOUR GENERATOR e Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK e Use approved spark plug tester e DO NOT check for spark with spark plug removed WARNING Starter and other rotating parts could entangle hands hair clothing or accessories resulting in serious injury e NEVER operate generator without protective housing or covers e DO NOT wear loose clothing jewelry or anything that could be caught in the starter or other rotating parts e Tie up long hair and remove jewelry CAUTION Excessively high operating speeds could result in minor injury Excessively low operating speeds impose a heavy load e DO NOT tamper with governor spring links or other parts to increase engine speed Generator supplies correct rated frequency and voltage when running at go
20. motor a altitudes inferiores a 762 metros 2 500 pies con el juego de gran altitud Tierra del sistema El generador dispone de una conexi n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA La tierra del sistema est conectada al cable de CA neutro que a su vez est conectado al bastidor del generador Requisitos especiales Es posible que haya normas u ordenanzas locales y nacionales en materia de seguridad e higiene en el trabajo aplicables al uso del generador Consulte con un electricista cualificado un inspector el ctrico o el organismo competente e En algunas zonas es obligatorio registrar los generadores en las compa as el ctricas locales e Si el generador se utiliza en una obra puede ser necesario cumplir normas y requisitos adicionales Conexi n al sistema el ctrico de un edificio Un electricista con licencia vigente debe instalar el conectador indicado para realizar las conexiones de la alimentaci n de reserva para el sistema el ctrico del edificio La conexi n debe aislar la alimentaci n del generador de la alimentaci n de la red p blica y debe cumplir con todas las leyes y normas el ctricas vigentes ADVERTENCIA El voltaje del generador podr a provocar descargas el ctricas o quemaduras que pueden producir lesiones graves o la muerte Utilice los equipos de transferencia indicados ideales para el uso deseado a fin
21. o provocado por accidente uso incorrecto modificaciones alteraciones mantenimiento incorrecto congelaci n o deterioro producido por productos qu micos Tambi n excluye cualquier complemento o accesorio que no se incluyera en el paquete original del producto No existe ninguna cobertura de garant a para equipos que se usen para generar energ a principal en lugar de energ a de uso ni para equipos que se usen en aplicaciones de soporte vital Esta garant a no incluye equipos o motores usados reacondicionados de segunda mano o de demostraci n Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante 80011053_ES Rev Espa ol 25 BRIGGSSSTRATTON Generador Port til Especificaciones del producto Vataje que Empieza 4 375 Vatios MATAS cs dsc dedo 3 500 Vatios Corriente valorada de Carga de C A a 120 Voltios 29 16 Amperios Frecuencia Nominal 60 Hz at 3600 rpm FASC da sus ce dns Monofasica Desplazamiento 250 cc 15 24 cu in Buj a Separaci n 0 76 mm 0 030 in Capacidad de Gasolina 15 14 Litros 4 galones Capacidad de Aceite 0 6 Litros 20 Onzas Partes de servicio com n Depurador desaire 491588 o 5043 Bujia de re stato MM P 491055 Buj a larga de vida de platino 5066 Botella
22. operativa que no est espec ficamente recomendada por el fabricante debe asegurarse de que no entra a peligro para usted ni para otras personas Tambi n debe asegurarse de que el procedimiento m todo de trabajo o t cnica operativa elegida no hace que el generador deje de ser seguro S mbolos sobre la seguridad y significados A Descarga El ctrica gt gt a Gases T xicos Contragolpe D D Fuego Explosi n Manual del Operario Partes en Objetos Superficie Movimiento Voladores Caliente El s mbolo de alerta de seguridad indica un posible riesgo para su integridad f sica Se utiliza una palabra de se alizaci n PELIGRO ADVERTENCIA o PRECAUCION junto con el s mbolo de alerta para designar un grado o nivel de gravedad de riesgo Se puede utilizar un s mbolo de seguridad para representar el tipo de riesgo La palabra de se alizaci n AVISO se utiliza para hacer referencia a una pr ctica no relacionada con una lesi n f sica PELIGRO indica un riesgo que de no evitarse provocar la muerte o lesiones de gravedad AM ADVERTENCIA indica un riesgo que de no evitarse podr a provocar la muerte o lesiones de gravedad A PRECAUCI N indica un riesgo que de no evitarse podr a provocar lesiones leves o moderadas AVISO hace referencia a una pr ctica no relacionada con una lesi n f sica ADVERTENCIA Determinados componentes en este producto y los accesorios relacionados contienen
23. or calendar intervals whichever occurs first More frequent service is required when operating in adverse conditions noted below e Change engine oil Every 8 Hours or Daily e Clean debris e Check engine oil level Every 25 Hours or Yearly e Service engine air cleaner Every 50 Hours or Yearly e Change engine oil Every 100 Hours or Yearly e Service fuel valve e Service spark plug e Inspect muffler and spark arrester e Clean cooling system 1 Service more often under dirty or dusty conditions General Recommendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain your generator All service and adjustments should be made at least once each season A new spark plug and clean air filter assure proper fuel air mixture and help your engine run better and last longer Follow the requirements in the Maintenance Schedule chart above Emissions Control Maintenance replacement or repair of the emissions control devices and systems may be performed by any non road engine repair establishment or individual However to obtain no charge emission
24. soporte de montaje 5 Inserte el pasador de retenci n D a trav s del orificio del extremo del eje 6 Repita los pasos 2 al 5 para asegurar la segunda rueda 7 Haga coincidir los orificios de la pata de apoyo E con los del armaz n del generador 8 Monte la pata de apoyo con dos tornillos de cabeza de 16 mm F y dos tuercas hexagonales M8 G Apriete con la llave de cubo de 13 mm y con la llave de 13 mm 9 Vuelva a colocar el generador en la posici n normal de funcionamiento apoyado en las ruedas 10 Introduzca el soporte del asa en el bastidor del generador 11 Monte el asa H con dos tornillos de cabeza de 50 mm J y dos tuercas hexagonales M8 K Apriete con la llave de cubo de 13 mm y con la llave de 13 mm Agregar aceite al motor 1 Coloque la generador en una superficie plana y nivelada 2 Limpie la zona de alrededor del orificio de llenado de aceite y quite el tap n amarillo 3 Con la ayuda de un embudo opcional vierta lentamente todo el contenido de la botella de aceite por el orificio de llenado de aceite AVISO Un tratamiento inadecuado de la generador podr a da arla y acortar su vida til e NO procure acodar ni empezar el motor antes ha sido atendido a apropiadamente con el aceite recomendado Esto podr a provocar una aver a en el motor 4 Vuelva a colocar el tap n y apri telo firmemente Espa ol o Agregue combustible El combustible debe reunir los sigu
25. sustancias qu micas declaradas cancer genas causantes de malformaciones y otros defectos cong nitos por el Estado de California L vese las manos despu s de manipular estos elementos ADVERTENCIA El escape del motor de este producto contiene elementos qu micos reconocidos en el Estado de California por producir c ncer defectos de nacimiento u otros da os de tipo reproductivo BRIGGSandSTRATTON COM PELIGRO El uso de un generador en un espacio interior PUEDE PROVOCAR LA MUERTE EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono un veneno invisible e inodoro NUNCA utilice un generador Utilicelo solo en el en el interior de una casa o EXTERIOR alejado de un garaje AUNQUE haya ventanas puertas y ventanas y puertas abiertas aberturas de ventilaci n ADVERTENCIA PELIGRO DE GAS VENENOSO Los gases del escape del motor contienen mon xido de carbono un gas venenoso que podr a matarlo en minutos NO tiene olor color ni sabor Aun si no puede oler los vapores del escape podr a estar expuesto al gas de mon xido de carbono e Utilice este producto NICAMENTE a la intemperie lejos de ventanas puertas y ventilaciones para reducir el riesgo de que el gas de mon xido de carbono se acumule y entre en los espacios habitados Instale alarmas para detectar mon xido de carbono operadas con bater as o enchufables con bater as de repuesto de acuerdo con las instr
26. vents J 1 Features and Controls LLI Read this Operator s Manual and safety rules before operating your generator Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference AIR Dr 71 LS 24 DR AAA gt A Rocker Switch Set this switch to ON I before using recoil starter Set switch to OFF 0 to shut off engine B 120 Volt AC 30 Amp Travel Trailer Receptacle May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical travel trailer loads C Circuit Breakers Push to reset circuit breakers are provided to protect the generator against electrical overload D 120 Volt AC 20 Amp GFCI Duplex Receptacle May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads E Oil Fill Cap Check and add engine oil here F Oil Drain Plug Drain engine oil here G Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area 14 8 Re o H Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester scr
27. ALEJADO NO PONGA EL GENERADOR EN FUNCIONAMIENTO EN NINGUNA DE LAS SIGUIENTES UBICACIONES Entra Porche S tano Espacio de acceso casa y el tubo de escape dirigido hacia ventanas puertas y ventilaciones 12 BRIGGSandSTRATTON COM Ubicaci n de operaci n del generador port til para REDUCIR EL RIESGO DE INCENDIOS ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales combustibles y las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte e El generador port til debe estar por lo menos a 1 5 m 5 pies de cualquier estructura saliente rbol ventana puerta cualquier abertura en la pared arbusto o vegetaci n que tenga m s de 30 5 cm 12 pulgadas de altura NO coloque el generador port til bajo una plataforma u otro tipo de estructura que pueda limitar el flujo de aire Las alarmas de humo SE DEBEN instalar bajo techo y su mantenimiento se debe realizar en las mismas condiciones de acuerdo con las instrucciones recomendaciones del fabricante Las alarmas de mon xido de carbono no pueden detectar el humo NO coloque el generador port til de una manera diferente a la mostrada EJEMPLO DE UBICACI N PARA REDUCIR EL RIESGO DE INCENDIOS LU 1 5m 5 ft min gt Dirija el escape LEJOS de ventanas puertas y conductos de ventilacio
28. NG MAXIMIUM FUEL Fuel is flammable and explosive WARNING AVERTISSEMENT ENEE BAFFLE which could cause burns or fire resulting in death serious injury l P T Se and or property damage Failure to read and follow these DO NOT fill fuel above baffle instructions can result in death bodily EE AAA Always allow space for fuel injury and or property damage oe 312728 L omission de lire et de suivre les instructions pourrait entra ner la mort des blessures corporelles ou des dommages mat riels Read instructions before running generator Veuillez lire les instructions avant de mettre la g n ratrice en marche Engines emit carbon monoxide DO NOT run in enclosed area Le moteur d gage du monoxyde de carbone NE PAS faire fonctionner dans un espace ferm Gasoline is flammable Allow engine to cool before refueling L essence est inflammable Laissez refroidir le moteur avant de remplir le r servoir High voltage DO NOT operate in wet conditions Haute tension NE PAS faire fonctionner dans un milieu d tremp Transfer switch MUST be used to connect generator to building Le commutateur de transfert DOIT tre utilis pour raccorder la g n ratrice l difice Muffler area is hot DO NOT touch of Les surfaces environnantes JU du silencieux sont chaudes NE PAS toucher AG 194984 a Espanol Descripci n del equipo Mm Lea atentamente este manu
29. ON Avoid prolonged or repeated skin contact with used motor oil e Used motor oil has been shown to cause skin cancer in certain laboratory animals e Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change the oil while the engine is still warm from running as follows 1 Make sure unit is on a level surface 2 Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug A The oil drain plug is located at base of engine opposite carburetor 4 Remove oil drain plug and drain oil completely into a suitable container 5 Reinstall oil drain plug and tighten securely Remove oil fill cap 6 Slowly pour oil about 20 oz into oil fill opening B to the point of overflowing C at oil fill cap DO NOT overfill 7 Reinstall oil fill cap Finger tighten cap securely 8 Wipe up any spilled oil Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner Clean or replace more often if operating under dusty or dirty conditions To service the air cleaner follow these steps 1 Loosen screws D and remove air cleaner cover E 2 Carefully remove cartridge F from base G 3 Install clean or new air cleaner assembly inside cover Dispose of old filter pr
30. ONSERVE LOS RECURSOS DEPOSITE EL ACEITE USADO EN UN PUNTO DE RECOGIDA Cambie el aceite cuando el motor siga estando caliente despu s de haber funcionado 1 Aseg rese de que la unidad est en una superficie plana 2 Desconecte el cable de la buj a de esta y col quelo donde no pueda entrar en contacto con la buj a 3 Limpie la zona de alrededor del tap n de vaciado de aceite A situado en la base del motor al otro lado del carburador 4 Quite el tap n de llenado de aceite y vac e todo el aceite en un recipiente adecuado 5 Vuelva a colocar el tap n de vaciado y apri telo bien Quite el tap n de llenado de aceite 6 Vierta lentamente unos 0 6 litros 20 onzas de aceite por el orificio de llenado B hasta el punto de desbordamiento C NO a ada aceite en exceso 7 Vuelva a colocar el tap n de llenado de aceite apri telo firmemente a mano 8 Limpie los residuos de aceite Servicio del depurador de aire Si se utiliza con un filtro de aire sucio el motor no funcionar correctamente y puede sufrir da os L mpielo o reempl celo m s a menudo si la unidad funciona bajo condiciones de suciedad o polvo excesivo Para dar servicio al filtro de aire siga los pasos que se detallan a continuaci n 1 Afloje los tornillos D y quite aire la cubierta m s limpia E 2 Con cuidado quite cartucho F de base G 3 Instale limpie o nuevo aire la asamblea m s limpia dentro de la c
31. Opere el generador solamente en superficies niveladas pies est n mojados NO it d l ficad ni n e NO exponga al generador a una humedad excesiva polvo permita que personas descalificadas o ni os op suciedad o vapores corrosivos o sirvan al generador e NO inserte cualquier objeto a traves de las ranuras de e Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas e Conecte las cargas el ctricas en la OFF posici n luego encienda ON para su operaci n e Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador ADVERTENCIA El arrancador y otras piezas sillas r eea a rotativas podr an enredarse en las manos I IOS aparatos conectados se sobre calientan apaguelos y descon ctelos del generador el pelo la ropa u otros accesorios y e Apague el generador si power lesiones are Se pierde la salida el ctrica e NUNCA utilice la generador sin sus carcasas o tapas de El equipo produce chispas humo o emite llamas protecci n La unidad vibra de una manera excesiva e NO utilice ropa suelta joyas ni objetos que podr an quedar atrapados en el arrancador o en otras piezas rotativas e Ate para arriba el pelo largo y quite la joyer a 8 BRIGGSandSTRATTON COM Montaje Su generador requiere de ciertos procedimientos de montaje y solo estar listo para ser utilizado despu s de haberle suministrado servicio con el combust
32. TTON COM Almacenamiento El generador deber ser encendido al menos una vez cada siete d as y deber dejarlo funcionar al menos durante 30 minutos Si no puede hacer esto y debe almacenar la unidad por m s de 30 d as siga las siguientes instrucciones para preparar su unidad para almacenamiento Generador e Limpie el generador como est descrito en Limpieza en la secci n Mantenimiento e Revise que las ranuras para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas Almacenamiento para periodos prolongados El combustible puede haberse echado a perder si se ha almacenado por m s de 30 d as El combustible echado a perder provoca la formaci n de residuos cidos y de carbonilla en el sistema de combustible y en los componentes b sicos del carburador Para mantener el combustible en buen estado use Briggs amp Stratton Advanced Formula Fuel Treatment amp Stabilizer disponible donde sea que se vendan piezas de servicio originales de Briggs amp Stratton No es necesario vaciar el motor de gasolina si se anade estabilizador de combustible conforme a las instrucciones Ponga en funcionamiento el motor durante 2 minutos para que el estabilizador circule por todo el sistema de combustible antes de almacenarlo Si no se ha a adido un estabilizador de combustible a la gasolina deber vaciar completamente el motor utilizando un contenedor homologado Deje funcionar el motor hast
33. a ON 1 posici n y compruebe si hay fugas En caso afirmativo sustituya la v lvula de combustible Mantenimiento del motor ADVERTENCIA Las chispas involuntarias podr an provocar incendios o A electrocucion que pueden provocar lesiones graves o la muerte CUANDO AJUSTE O HAGA REPARACIONES A SU MAQUINA GENERADOR e Siempre desconecte el alambre de la bujia y coloquelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR e Utilice un comprobador de buj as homologado e NO comprueba la chispa sin la buj a instalada 20 Aceite Recomendaciones sobre el aceite Para obtener el mejor rendimiento recomendamos utilizar aceites certificados con garant a Briggs amp Stratton Tambi n se pueden utilizar otros aceites detergentes de alta calidad con clasificaci n de servicio SF SG SH SJ o superior NO utilice aditivos especiales Las temperaturas exteriores determinan la viscosidad adecuada del aceite para el motor Utilice el cuadro para seleccionar la mejor viscosidad para el intervalo de temperatura exterior previsto YE eG 104 gt N 40 86 o la le 30 68 u 5 HS 20 50 9 10 32 0 14 gt ES 10 4 __ _ 20 22 _______ A 230 Por debajo de 4 C 40 F el uso de aceite SAE 30 provocar dificultades de arranque Por encima de 27 C 80 F el uso de aceite 10W30 puede aumentar el c
34. a que se agote el combustible Se recomienda utilizar un estabilizador de combustible en el contenedor de almacenamiento para mantener la gasolina en buen estado ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y explosivos lo que podr a provocar quemaduras incendios o explosiones as como lesiones graves o incluso la muerte CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE e Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible CUANDO VAC E EL DEP SITO e DETENGA el motor del generador y d jelo enfriar durante al menos 2 minutos antes de quitar el tap n de combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Vac e el dep sito de combustible a la intemperie Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n Compruebe frecuentemente que las l neas de combustible el tanque el tap n y los accesorios no est n rotos o tengan fugas C mbielos si es necesario NO encienda un cigarrillo o fume Cambio de aceite Con el motor todav a caliente drene el aceite de la caja del ciguenal Vuelva a llenarlo con el grado de aceite recomendado Vea Cambio de Aceite del Motor en Mantenimiento del motor Otras sugerencias pa
35. al y familiar cese con el generador Conozca sus aplicaciones limitaciones y riesgos Este generador funciona en base a un motor de campo el ctrico giratorio y de corriente alterna CA Fue dise ado con la finalidad de proveer energ a el ctrica para l mparas el ctricas aparatos herramientas y cargas de motor compatibles El campo giratorio del generador se mueve a unas 3 600 rpm con un motor de un uno cilindro AVISO Sise supera la capacidad de los generadores en vatios amperios se podr a da ar el generador y o los dispositivos el ctricos conectados a l e NO exceda la capacidad en vatios amperios del generador Consulte No sobrecargar el generador en la secci n Operando Se ha realizado el m ximo esfuerzo para reunir en este documento la informaci n m s precisa y actualizada No obstante nos reservamos el derecho de modificar alterar o mejorar de cualquier otra forma el generador en cualquier momento y sin previo aviso El Sistema de Control de Emisiones para este generador est garantizado para juegos est ndares por la Agencia de Protecci n Ambiental y el Consejo de recursos de aire de California Informaci n importante de seguridad El fabricante no puede anticipar todas las posibles circunstancias que podr an conllevar peligro Por lo tanto las advertencias de este manual as como las etiquetas y placas de la unidad no incluyen todo Si usa un procedimiento m todo de trabajo o t cnica
36. annot see or smell Only use OUTSIDE and far away from windows doors and vents NEVER use inside a home or garage EVEN IF doors and windows are open e By law it is required in many states to have a Carbon Monoxide CO alarm A in operating condition in your home Install maintain battery operated carbon monoxide alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s instructions A CO alarm is an electronic device that detects hazardous levels of CO When there is a buildup of CO the alarm will alert the occupants by flashing visual indicator light and alarm Smoke alarms cannot detect CO gas Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces DO NOT run this product inside homes garages basements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off Your neighbor s home may be exposed to the engine exhaust from your portable generator and must be considered when deciding on a location for the safe operation of your portable generator ALWAYS place this product downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizz
37. arranca contin e con el paso 7 e Siel motor no arranca proceda con el paso 6 ADVERTENCIA El retroceso repliegue r pido del cable del arrancador impedir que el usuario suelte el cable a tiempo y tirar de su mano y brazo hacia el motor lo que podr a provocar fracturas contusiones o esguinces as como lesiones graves e Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso e NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento 16 6 Mueva la palanca de choque hasta la posici n HALF media y accione dos veces la manija de retroceso e Siel motor no arranca repita los pasos desde 5 hasta 7 7 Coloque la palanca de retroceso en la posici n de RUN 1 Si el motor vacila mueva la palanca de retroceso hasta la posici n media HALF hasta que el motor marche suavemente y luego col quelo en la posici n de marcha RUN 1 AVISO Si el motor se desborda coloque la palanca estranguladora en la posici n RUN I 1 e intente arrancarlo hasta conseguirlo AVISO Si el motor arranca despu s de tirar tres veces del arrancador pero no sigue funcionando o si la unidad se para en funcionamiento aseg rese de que la unidad est en una superficie plana y compruebe que el nivel de aceite del ciguenal es correcto La unidad puede equiparse con un dispositivo de prote
38. bustible etc limitaciones de la aplicaci n condiciones ambientales de uso temperatura humedad altitud y variaciones entre distintos motores de un mismo modelo Debido a limitaciones de fabricaci n y capacidad Briggs Stratton puede sustituir un motor de una potencia nominal mayor por este motor Este generador est clasificado conforme a la norma C22 2 N 100 04 motores y generadores de la Asociaci n Canadiense de Normas Canadian Standards Association CSA y la norma PGMA G200 norma para la evaluaci n y validaci n del rendimiento de los generadores port tiles de la Asociaci n de Fabricantes de Generadores Port tiles Portable Generator Manufacturers Association PGMA Briggs 8 Stratton Power Products Group LLC P O Box 702 Milwaukee Wisconsin 53201 0702 U S A 26 800 743 4115 BRIGGSandSTRATTON COM
39. cables el ctricos da ados o sobrecargados podr an sobrecalentarse y producir arcos y quemaduras lo que provocar a lesiones graves o incluso la muerte e Utilice exclusivamente cables regulados para las cargas aplicadas e Respete todas las medidas de seguridad de los cables el ctricos e Examine los juegos de cables antes de cada uso Toma de 120 VCA 30 A para remolques Use un enchufe NEMA TT 30 con esta toma Conecte un cable para remolque de 3 hilos con capacidad para cargas de 125 VCA a 30 A en este enchufe NEMA TT 30 Tierra Verde Cargado 120V Neutro Use esta toma para cargas de remolque de 120 VCA 60 Hz monof sicas que requieran un m ximo de 3 500 vatios 3 5 kW de potencia a 29 16 A Este tomacorriente est protegido por medio de un disyuntor de rearme por presi n AVISO Las tomas el ctricas pueden marcar un valor nominal mayor que la capacidad de salida del generador e NUNCA intente conectar un dispositivo que requiera m s amperaje del que el generador o la toma el ctrica pueden suministrar e NO sobrecargar el generador V ase No sobrecargar el generador 120 Volt AC 20 Amp GFCI Recept culo Dobles Esta recept culo est protegido en contra de sobrecargas por un corto circuitos de del tipo empuje para reposicionar Use esta recept culo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amps
40. caci n del generador O O O El generador se debe colocar en un rea en la que no se acumule el mon xido de carbono CO Consulte Colocaci n del generador para reducir el riesgo de envenenamiento por mon xido de carbono El generador se debe colocar en un rea a prueba de incendios Consulte Colocaci n del generador para reducir el riesgo de incendio El generador se debe colocar en una superficie plana y nivelada Aceite y combustible Ol Ol O Motor lleno hasta el nivel adecuado de aceite Consulte Agregar aceite al motor El tanque de combustible se debe llenar hasta el deflector o por debajo de l Consulte Adici n de combustible Inspeccione siempre las l neas el tanque el tap n y los accesorios de combustible antes de usar el generador NO lo use si detecta fugas de combustible o da o Sistema el ctrico O O O Ol Ol Cuando realice conexiones al sistema el ctrico de un edificio instale el equipo de transferencia indicado Consulte Conexi n al sistema el ctrico de un edificio Los valores nominales de los cables el ctricos deben ser las adecuadas para las cargas deseadas Consulte Juegos de cables y tomas el ctricas Los cables el ctricos no se deben extender a trav s de puertas ventanas orificios en techos paredes o pisos Inspeccione los cables el ctricos perfectamente antes de usarlos NO los use si est n da ados Es necesario entender y seguir todas las indicaciones de segur
41. cci n de bajo nivel de aceite En caso afirmativo el nivel del aceite debe ser adecuado para que el motor arranque ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales combustibles y las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El contacto con la zona del silenciador podr a producir quemaduras y lesiones graves e NO toque las superficies calientes y EVITE los gases del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior Utilizar el motor en un terreno boscoso con maleza o cubierto de hierba constituye una infracci n al C digo de recursos p blicos de California a menos que el sistema de escape est equipado con una pantalla apagachispas de acuerdo a la definici n de la Secci n 4442 que se mantenga en buenas condiciones de funcionamiento En otros estados o jurisdicciones federales puede haber leyes similares en vigor P ngase en contacto con el fabricante el vendedor o el distribuidor del equipo original para obtener una pantalla apagachispas dise ada para el sistema de escape instalado en este motor Las piezas de recambio deben ser las mismas que las piezas originales y estar instaladas en la misma posici n BRIGGSandSTRATTON COM Conexi n de cargas el ctricas 1 Deje que el m
42. co Art culos b sicos Luz 75 vatios Ventilador del horno 1 2 hp Bomba de sentina 1 3 hp n Refrigerador congelador Bomba para pozo de agua 1 2 hp 1000 Sistema de calefacci n MI 10 1200 Humidificador 49 13 gal Aire acondicionado central 3800 1000 1000 Horno de microondas 1000 Estufa el ctrica 8 pieza Reproductor de DVD CD C Ventana con AC 10 000 BTU 24 000 BTU Televisi n a color 27 pulg Computadora personal con Sistema de seguridad Receptor de est reo monitor de 17 pulg Radio reloj AM FM Control autom tico para puerta wn o z TER ad O 5 e amp D 9 Q se y Q o S E N T 3 9 D ae y O 2 D O e Q Calentador el ctrico de agua L mpara hal gena de cuarzo para trabajo Atomizador sin aire 1 3 hp Sierra reciprocante Taladro el ctrico 1 2 hp Sierra circular 7 1 4 pulg Aplanadora de tablas 6 pulg Sierra de mesa sierra de brazo radial 10 pulg La potencia que aparece en la lista es aproximada Compruebe la herramienta o aparato el ctrico para obtener la potencia real BRIGGSandSTRATTON COM Mantenimiento Plan de mantenimiento Siga los intervalos de horas o de calendario los que sucedan antes Si opera en condiciones adversas se aladas m s abajo es necesario un mantenimiento m s frecuente Primeras Cinco 5 Horas e Cambie el aceite del motor Cada 8 horas o diario e Limp
43. conectadas El generador est sobrecarga Velocidad del motor es muy lenta Circuito del generador en corto Filtro de combustible obstruido o sucio Interruptor balanc n del motor OFF 0 posici n V lvula del combustible OFF 0 posici n Nivel de aceite insuficiente Depurador de aire sucio Filtro de combustible obstruido o sucio Sin gasolina Gasolina vieja El cable de la buj a no est en malas la buj a Buj a defectuosa Agua en la gasolina Sobrecebado Mezcla de combustible excesivamente rica La v lvula de entrada est atascada est cerrada El motor ha perdido compresi n La carga es muy alta Filtro de aire sucio Filtro de combustible obstruido o sucio Carburador con mezcla de aire combustible muy rica o muy pobre Filtro de combustible obstruido o sucio Accion Reposicione el interruptor Revise y repare Conecte otro dispositivo que est buenas condiciones Contacte el distribuidor de servicio autorizado Desconecte la carga el ctrica en corto Vea No Sobrerecarque Generador Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Limpie o cambie el filtro de combustible Coloque del interruptor balanc n del motor ON I posici n Gire la v lvula del combustible a la ON I posicion Llene el carter ha
44. connects the generator frame components to the ground terminals on the AC output receptacles The system ground is connected to the AC neutral wire the neutral is bonded to the generator frame Special Requirements There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction e In some areas generators are required to be registered with local utility companies e f the generator is used at a construction site there may be additional regulations which must be observed Connecting to a Building s Electrical System Connections for standby power to a building s electrical system must use a listed transfer switch installed by a current licensed electrician The connection must isolate the generator power from the utility power and must comply with all applicable laws and electrical codes A WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury e Use listed transfer equipment suitable for the intended use to prevent backfeed by isolating generator from electric utility workers When using generator for backup power notify utility company Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work
45. covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws Contact the original equipment manufacturer retailer or dealer to obtain a spark arrester designed for the exhaust system installed on this engine Replacement parts must be the same and installed in the same position as the original parts Clean or replace the spark arrester as follows 1 To remove muffler heat shield A from muffler B remove four screws that connect guard to muffler bracket 2 Remove four screws that attach spark arrester screen C 3 Inspect screen and obtain a replacement if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with commercial solvent 4 Reattach screen and muffler guard 22 Clean Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly For this reason we recommend you have a Briggs amp Stratton authorized dealer clean the cooling system D per recommended intervals see Maintenance Schedule in the Maintenance section Equally important is to keep top of engine free from debris Also see Cleaning A T 2e 7 A 2 W 5 S i ae APE Carburetor Adjustment The carbureto
46. de aceite de motor 020 100005 Estabilizador de combustible 100120 o 100117 Apagachispas ae Ma 83083GS Potencia nominal El valor de potencia bruta nominal de cada modelo de motor de gasolina est indicado en una etiqueta conforme al c digo J1940 Procedimiento de valoraci n de potencia y par de torsi n para motores peque os de la Society of Automotive Engineers Sociedad de Ingenieros de Automoci n SAE y se ajusta conforme al c digo SAE J1995 Los valores de par de torsi n se obtienen a 2600 RPM para los motores con indicaci n de rpm en la etiqueta y a 3060 RPM para todos los dem s los valores de potencia se obtienen a 3600 RPM Las curvas de potencia bruta se pueden ver en www BRIGGSandSTRATTON COM Los valores de potencia neta se obtienen con el escape y filtro de aire instalados mientras que los valores de potencia bruta se obtienen sin estos elementos La potencia bruta real del motor es superior a la potencia neta del motor y depende entre otros factores de las condiciones ambientales de uso y de las variaciones entre distintos motores del mismo modelo Dada la amplia variedad de productos que utilizan nuestros motores es posible que el motor de gasolina no desarrolle la potencia bruta nominal en determinados equipos Esta diferencia se debe a los siguientes factores entre otros variedad de componentes del motor filtro de aire escape carga refrigeraci n carburador bomba de com
47. ecified below it will repair or replace free of charge any part that is defective in material or workmanship or both Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for and is subject to the time periods and conditions stated below For warranty service find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTATTON COM The purchaser must contact the Authorized Service Dealer and then make the product available to the Authorized Service Dealer for inspection and testing There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to the warranty period listed below or to the extent permitted by law Liability for incidental or consequential damages are excluded to the extent exclusion is permitted by law Some states or countries do not allow limitations on how long an implied warranty lasts and some states or countries do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country WARRANTY PERIOD Item Consumer Use Commercial Use Equipment 24 months A 12 months Engine 24 months 12 months Battery if equipped 3 months None A After 12 m
48. een J Recoil Starter Used to start the engine manually K Air Cleaner Protects engine by filtering dust and debris out of intake air L Choke Lever Used when starting a cold engine M Fuel Valve Used to turn fuel supply on and off to engine N Fuel Tank Capacity of four 4 U S gallons 15 14 1 Items Not Shown Engine Identification Provides model type and code of engine Please have these readily available if calling for assistance Identification Label Provides model and serial number of generator Please have these readily available if calling for assistance BRIGGSandSTRATTON COM Cord Sets and Receptacles 120 Volt AC 20 Amp GFCI Duplex Receptacle Use only high quality well insulated grounded The duplex receptacle is protected against overload by a push to reset circuit breaker extension cords with the generator s receptacles Inspect extension cords before each use Check the ratings of all extension cords before you use them Check operator s manuals of devices to be powered for the manufacturers recommendations WARNING Damaged or overloaded electrical cords could overheat arc and burn resulting in death or serious injury e ONLY use cords rated for your loads e Follow all safeties on electrical cords e Inspect cord sets before each use Use receptacle to operate 120 Volt AC single phase l 60 Hz electrical loads requiring up to 2 400 watts 120
49. el gas CO ssl e Utilice este producto NICAMENTE a la intemperie lejos de ventanas puertas y ventilaciones para reducir el riesgo de que el gas de mon xido de carbono se acumule y entre en los espacios habitados NO utilice este producto dentro de casas garajes s tanos entresuelos cobertizos o en otros espacios parcialmente cerrados a n si utiliza ventiladores o deja las puertas y ventanas abiertas para favorecer la ventilaci n El mon xido de carbono puede acumularse r pidamente en estos espacios y perdurar ah durante horas aun despu s de que este producto se haya apagado e Las casas vecinas puede quedar expuesta a los gases de escape del motor de su generador port til y esto debe tomarse en cuenta al momento de decidir la ubicaci n para que el generador port til funcione de manera segura e SIEMPRE coloque este producto en direcci n del viento y dirija el escape del motor en sentido contrario a los espacios habitados Si comienza a sentirse mal mareado o d bil cuando use este producto busque aire puro DE INMEDIATO Acuda a un m dico Es posible que se haya envenenado con mon xido de carbono Espa ol EJEMPLO DE UBICACI N PARA REDUCIR EL RIESGO DE ENVENENAMIENTO POR MON XIDO DE CARBONO y Alarma de CO en areas de vivienda Opere solo a la INTEMPERIE Dirija el escape LEJOS y LEJOS de ventanas oo al ertas y ventilaciones conductos de ventilaci n pu y 1 p LO
50. endimiento de los generadores port tiles de la Asociaci n de Fabricantes de Generadores Port tiles Portable Generator Manufacturers Association PGMA BRIGGS 8 STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Muchas gracias por comprar este generador Briggs amp Stratton de gran calidad Nos alegra que haya depositado su confianza en la marca Briggs Stratton Siempre que sea utilizado de acuerdo con las instrucciones de este manual su generador Briggs Stratton le proporcionar muchos a os de buen funcionamiento Este manual contiene informaci n sobre seguridad para hacerle consciente de los riesgos asociados a los generadores y mostrarle c mo evitarlos Este generador se ha dise ado exclusivamente para suministrar energ a el ctrica a cargas compatibles de iluminaci n electrodom sticos herramientas y motores No debe utilizarse para ning n otro fin Es importante leer detenidamente y comprender estas instrucciones antes de poner en marcha o utilizar el equipo Conserve este manual original para futuras consultas Este generador requiere montaje final antes de ser usado Consulte la secci n Montaje de este manual donde encontrar instrucciones para el montaje final Siga las instrucciones al pie de la letra D nde encontrarnos Usted no tendr que ir muy lejos para encontrar el servicio t cnico de Briggs Stratton para su generador Consulte las P ginas Amarillas Hay m s de 30 000 proveedore
51. ergent oils are acceptable if classified for service SF SG SH SJ or higher DO NOT use special additives Outdoor temperatures determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected OF C 104 _Y N 40 86 o 30 68 u1 _ S 20 50 9 10 32 0 14 _ _ E OS 10 4 4 __ _ 20 22 nv A ZH 230 Below 40 F 4 C the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 10W30 may cause increased oil consumption Check oil level more frequently Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation Keep oil level maintained 1 Make sure generator is on a level surface 2 Clean area around oil fill and remove oil fill cap 3 Verify oil is at the point of overflowing at oil fill opening 4 Replace and tighten oil fill cap Adding Engine Oil 1 Make sure generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the point of overflowing at oil fill 4 Replace and tighten oil fill cap BRIGGSandSTRATTON COM Changing Engine Oil If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often CAUTI
52. fire resulting in death or serious injury Contact with muffler area could cause burns resulting in serious injury e DO NOT touch hot parts and AVOID hot exhaust gases e Allow equipment to cool before touching e Keep at least 5 ft 1 5 m of clearance on all sides of generator including overhead e ltis a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws Contact the original equipment manufacturer retailer or dealer to obtain a spark arrester designed for the exhaust system installed on this engine Replacement parts must be the same and installed in the same position as the original parts BRIGGSandSTRATTON COM Connecting Electrical Loads 1 Let engine stabilize and warm up for a few minutes after starting 2 Plug in and turn on the desired 120 Volt AC single phase 60 Hz electrical loads NOTICE e DO NOT connect 240 Volt loads to the 120 Volt GFCI receptacle e DO NOT connect 3 phase loads to the generator e DO NOT connect 50 Hz loads to the generator e DONOT OVERLOAD THE GENERATOR See Don t Overload Generator NOTICE Exceeding generators wattage amperage capacity could damage generator and or electrical devices co
53. gine for 2 minutes to circulate the stabilizer throughout the fuel system before storage If gasoline in the engine has not been treated with a fuel stabilizer it must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness WARNING Fuel and its vapors are extremely flammable and explosive which could DA cause burns fire or explosion resulting in death or serious injury WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK e Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they could ignite fuel vapors WHEN DRAINING FUEL e Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Drain fuel tank outdoors Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke Change Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil in Engine Maintenance Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions 2 Replace fuel can
54. he model revision and serial number from the identification label available See Features and Controls for identification label location Unpack Generator 1 Set the carton on a rigid flat surface 2 Remove everything from carton except generator 3 Open carton completely by cutting each corner from top to bottom 4 Leave generator on carton to install wheel kit Shipment Contents The generator is supplied with e Engine oil bottle e Operator s manual e Wheel kit Install Wheel Kit NOTICE Wheel kit is not intended for over the road use You will need the following tools to install these components e 13 mm wrench e Socket wrench with 13 mm socket Install the wheel kit as follows 1 Tip generator so that engine side is down 2 Slide axle stud A through wheel B ys NOTICE Be sure to install wheel with raised hub inboard 3 Slide a spacer C over axle stud on back side of wheel 4 Slide axle stud through mounting bracket 5 Insert retaining pin D through hole on axle stud 6 Repeat steps 2 through 5 to secure second wheel 7 Line up holes in support leg E with holes in generator frame 8 Attach support leg using two 16 mm capscrews F and two M8 hex nuts G Tighten with a 13 mm socket wrench and 13 mm wrench 9 Return generator to normal operating position resting on wheels 10 Slide handle bracket over generator frame and attach handle H using two 50 mm capscrews J
55. ible y aceite recomendados Si usted tiene problemas con el montaje de su generador por favor llame a la l nea de ayuda para generadores al 1 800 743 4115 Si llamar para la ayuda tiene por favor el modelo la revisi n y el n mero de serie de etiqueta de identificaci n disponible Consulte la ubicaci n en la secci n Caracter sticas y mandos Desembalaje del generador 1 Coloque la caja de cart n en una superficie r gida y plana 2 Abra completamente la caja de cart n cortando cada una de sus esquinas de arriba abajo 3 Saque todo el contenido de la caja de cart n a excepci n del generador 4 Mantenga el generador sobre el cart n para instalar el juego de ruedas Contenido de la caja El generador se entrega con e Aceite del motor e Manual del operario e Juego de ruedas Instale el juego de ruedas AVISO Este juego de ruedas no ha sido dise ado para ser usado en la carretera Necesitar las siguientes herramientas para instalar estos componentes e Llave de 13 mm e Llave de cubo de 13 mm Instale el juego de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el lado del motor quede abajo 2 Introduzca el extremo del eje A a trav s de la rueda B AVISO Compruebe que instala la rueda con el cubo elevado hacia el interior 3 Introduzca un espaciador C en el extremo del eje en la parte posterior de la rueda 4 Introduzca el extremo del eje a trav s del
56. idad de los cables el ctricos etiquetados Funcionamiento O Arranque el motor Consulte Arranque del motor Espa ol 3 Seguridad de operario Etiquetas de seguridad Las etiquetas de seguridad de la m quina que se muestran a continuaci n y en la p gina siguiente est n colocadas en la m quina para llamar la atenci n sobre posibles riesgos de seguridad A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home Only use OUTSIDE and or garage EVEN IF doors far away from windows and windows are open doors and vents 202997 Fire Hazard Operation of this equipment may create sparks that can start fires around AA dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements 208538 Hot engine exhaust gases can cause fire Reflective exhaust Les gaz d chappement de moteur chauds peuvent causer un incendie db heat can damage fuel tank causing fire Keep at least 5 ft PY La chaleur d chappement r fl chie peut endommager le r servoir d essence et causer un incendie 152 cm clearance from any combustibles or structure Laissez un d gagement d au moins 1 52 m 5 pi autour de tous mat riaux combustibles et structures including overhead y compris au dessus A BRIGGSandSTRATTON COM WARNI
57. ie los residuos e Compruebe el nivel de aceite Cada 25 horas o una vez al a o e Mantenimiento del filtro de aire Cada 50 horas o una vez al a o e Cambie el aceite del motor Cada 100 horas o una vez al a o e Servicio a la v lvula de combustible e Servicio a la buj a e Inspeccione el silenciador y la pantalla apagachispas e Limpie el sistema de refrigeraci n 1 Servicio m s a menudo bajo condiciones de suciedad o polvo Recomendaciones generales El mantenimiento peri dico mejorar el rendimiento y prolongar la vida til del generador Acuda a un distribuidor autorizado para reparar la unidad La garant a del generador no cubre los elementos que hayan sido sujetos al abuso o negligencia del operador Para recibir el valor completo de la garant a el operador deber mantener el generador de la forma descrita en este manual Se deber n llevar a cabo algunos ajustes peri dicamente para mantener correctamente su generador Todos los ajustes de la secci n Servicio y Ajustes de este manual deber n ser hechos por lo menos una vez en cada estaci n Una buj a nueva y un filtro de aire limpio garantizan una mezcla de combustible aire adecuada y ayuda a que su motor funcione mejor y tenga una vida til m s prolongada Cumpla con los requisitos de la tabla Plan de Mantenimiento descrita anteriormente Control de emisiones Cualquier establecimiento o individuo especializado en la reparaci n de motores
58. ientes requisitos e Gasolina sin plomo limpia y nueva e Un m nimo de 87 octanos 87 AKI 91 RON Para uso a gran altitud consulte Gran altitud e Se puede usar gasolina con un contenido de hasta 10 de etanol gasohol AVISO El uso de combustibles no aprobados podr a da ar el generador y anula la garant a e NO utilice gasolina no aprobada como E15 y E85 e NO mezcle aceite con gasolina ni modifique el motor para hacerlo funcionar con otros combustibles Para evitar la formaci n de carbonilla en el circuito de combustible siempre que a ada combustible m zclelo con un estabilizador Consulte Almacenamiento No todos los combustibles son iguales Si detecta problemas de arranque o de rendimiento despu s de utilizar un combustible pruebe a cambiar de proveedor o de marca Este motor est certificado para funcionar con gasolina Su sistema de control de emisiones es EM Modificaciones del motor ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y A explosivos lo que podria provocar quemaduras incendios o explosiones as como lesiones graves o incluso la muerte CUANDO ANADA COMBUSTIBLE e DETENGA el motor del generador y d jelo enfriar durante al menos 2 minutos antes de quitar el tap n de combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio
59. if it starts to rust Contaminated fuel will cause engine problems 3 If possible store unit indoors and cover it to give protection from dust and dirt 4 Cover unit with a suitable protective cover that does not retain moisture WARNING Storage covers could cause a fire A resulting in death or serious injury e DO NOT place a storage cover over a hot generator e Let equipment cool for a sufficient time before placing the cover on the equipment 5 Store generator in clean dry area 23 Troubleshooting Problem Engine is running but no AC output is available Engine runs good at no load but bogs down when loads are connected Engine will not start starts and runs rough or shuts down when running Engine lacks power Engine hunts or falters Circuit breaker is open Fault in generator Poor connection or defective cord set Connected device is bad Short circuit in a connected load Engine speed is too slow Generator is overloaded Shorted generator circuit Clogged or dirty fuel filter Rocker switch set to OFF 0 position Fuel Valve is in OFF 0 position Low oil level Dirty air cleaner Clogged or dirty fuel filter Out of fuel Stale fuel Spark plug wire not connected to spark plug Bad spark plug Water in fuel Flooded Excessively rich fuel mixture Intake valve stuck open or closed
60. jemplo da os producidos por un impacto o da os producidos por corrosi n qu mica agua Mantenimiento o reparaciones inadecuadas el producto debe someterse a labores de mantenimiento de acuerdo con los procedimientos y plazos establecidos en el manual del usuario y para el mantenimiento y las reparaciones se deben utilizar piezas Briggs amp Stratton originales o equivalentes La garant a no cubre los da os ocasionados por la falta de mantenimiento o el uso de piezas no originales Desgaste normal al igual que otros dispositivos mec nicos el producto est sujeto a desgaste incluso si se realiza un mantenimiento correcto Esta garant a no cubrir la reparaci n cuando el uso normal haya agotado la vida til de una pieza o del aparato Los accesorios y elementos de mantenimiento como filtros correas hojas cortantes y pastillas de freno excepto las pastillas de freno de los motores no est n cubiertos por la garant a por sus propias caracter sticas a no ser que la causa sea un defecto del material o de fabricaci n Combustible en mal estado o no aprobado para que este producto funcione correctamente se necesita combustible fresco que cumpla los criterios especificados en el manual del usuario Los da os al motor o al equipo causados por combustible en mal estado o por el uso de combustibles como por ejemplo las mezclas de etanol E15 o E85 no est n cubiertos por la garant a Otras exclusiones esta garant a excluye cualquier da
61. k or burn even if the circuit is GFCI protected NOTICE Receptacles may be marked with rating value greater than generator output capacity e Before using the GFCI receptacle ALWAYS push the e NEVER attempt to power a device requiring more test button to insure it works amperage than generator or receptacle can supply Testing the GFCI e DO NOT overload the generator See Don t Overload T GFCI h foll Generator est your outlet prior to each use as follows e Push the Test button The Reset button should pop out which should allow no power to reach the outlet Use a test lamp in each outlet to test this e If the GFCI tests good restore power by pressing the Reset button firmly until it is fully in place and locks in that position If the GFCI outlet does not reset properly do not use the outlet Call or take your generator to a local service center If the GFCI trips by itself at any time reset and test the outlet If the reset button does not pop out when the test button is pressed do not use the outlet Call or take your generator to a local service center 15 Operation Starting the Engine Disconnect all electrical loads from the generator Use the following start instructions 1 Make sure unit is on a level surface NOTICE Failure to start and operate the unit on a level surface could cause the unit not to start or shut down during operation 2 Turn the fuel valve A to the ON I
62. l 80011053_EN Rev 25 BRIGGSSSTRATTON Portable Generator Product Specifications Starting Wattage 4 375 Watts Wallage AA 3 500 Watts AC Voltage at 120 Volts 29 16 Amps Frequency 60 Hz at 3600 rpm Phab viaria adas cie Single Phase Displacement 15 24 cu in 250 cc Spark Plug Gap 0 030 in 0 76 mm Fuel Capacity 4 U S Gallons 15 14 Liters Oil Capacity 20 Ounces 0 6 Liters Common Service Parts Air Cleaner AS 491588 or 5043 Resistor Spark Plug 1 491055 Long Life Platinum Spark Plug 5066 Engine Oil Bottles M 100005 Fuel Stabilizer 100120 or 100117 Spark Arrester 83083GS Power Ratings The gross power rating for individual gasoline engine models is labeled in accordance with SAE Society of Automotive Engineers code J1940 Small Engine Power amp Torque Rating Procedure and is rated in accordance with SAE J1995 Torque values are derived at 2600 RPM for those engines with rpm called out on the label and 3060 RPM for all others horsepower values are derived at 3600 RPM The gross power curves can be viewed at www BRIGGSandSTRATTON COM Net power values are taken with exhaust and air cleaner installed whereas gross power values are collected without these attachments Actual gross engine power wi
63. l de vatios de M ximo de vatios de funcionamiento 3275 arranque 2350 Televisi n Luz 75 vatios Vatios de potencia continua totales 32 5 Potencia de salida adicional m s alta 2350 Salida total del generador requerida 5625 Control de la energ a Para prolongar la vida de su generador y los aparatos que conecte a l es muy importante tener cuidado cuando se le a aden cargas el ctricas No deber haber nada conectado a las tomas del generador antes de encender el motor El modo seguro y correcto de gestionar la energ a del generador es a adir las cargas secuencialmente como se indica a continuaci n 1 Sin tener nada conectado al generador encienda el motor tal como se describe en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato funciona adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada cargas que sobrepasen la capacidad del generador Tenga especial cuidado en contar con las cargas adicionales en la capacidad del generador como se describe arriba 18 GU A DE REFERENCIA DE POTENCIA EN VATIOS Nivel Nivel nominal en adicional funcionamiento de de vatios arranque de vatios Herramienta o aparato el ctri
64. ll be higher than net engine power and is affected by among other things ambient operating conditions and engine to engine variability Given the wide array of products on which engines are placed the gasoline engine may not develop the rated gross power when used in a given piece of power equipment This difference is due to a variety of factors including but not limited to the variety of engine components air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating conditions temperature humidity altitude and engine to engine variability Due to manufacturing and capacity limitations Briggs Stratton may substitute an engine of higher rated power for this engine This generator is rated in accordance with CSA Canadian Standards Association standard C22 2 No 100 04 motors and generators and PGMA Portable Generator Manufacturers Association standard PGMA G200 Standard for Testing and Validating Performance of Portable Generators Briggs amp Stratton Power Products Group LLC P O Box 702 Milwaukee Wisconsin 53201 0702 U S A 26 800 743 4115 BRIGGSandSTRATTON COM BRIGGSSSTRATION Generador portatil Manual del operario Este generador est clasificado conforme a la norma C22 2 N 100 04 motores y generadores de la Asociaci n Canadiense de Normas Canadian Standards Association CSA y la norma PGMA G200 norma para la evaluaci n y validaci n del r
65. lly being drawn towards occupied spaces Install battery operated carbon monoxide alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s instructions Smoke alarms cannot detect carbon monoxide gas DO NOT run this product inside homes garages basements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off ALWAYS place this product downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product get to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning WARNING Starter cord kickback rapid retraction will pull hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury e When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback e NEVER start or stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns fire or explosion resulting in death or serious injury WHEN ADDING OR DRAINING FUEL e Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen ca
66. mercial 4 Vuelva a instalar la pantalla y la protecci n del silenciador Sistema de refrigeraci n de aire Con el tiempo se pueden acumular residuos en las aletas de refrigeraci n del cilindro y pasar inadvertidos mientras no se desmonte parcialmente el motor Recomendamos que encargue la limpieza del sistema de refrigeraci n D a un distribuidor autorizado siguiendo los intervalos recomendados consulte la secci n Plan de Mantenimiento en la secci n Mantenimiento Es igualmente importante que no se acumulen residuos en la parte superior del motor ni en la pantalla giratoria Consulte la secci n Limpieza Ajuste del carburador El carburador de este motor es de baja emisi n Est equipado con una v lvula de mezcla de ralent no ajustable y en algunos casos con ralent regulado Los niveles de ralent regulado y velocidad m xima se ajustan en la f brica Si es necesario modificarlos acuda a un distribuidor de servicio PRECAUCI N Las velocidades de funcionamiento excesivamente altas podr an provocar lesiones leves Las velocidades excesivamente bajas incrementan la carga de trabajo e NO intente alterar el resorte las conexiones y otras partes del regulador para incrementar la velocidad del motor El generador suministra la frecuencia y el voltaje nominales correctos cuando funciona a una velocidad controlada NO modifique al generador en ninguna forma BRIGGSandSTRA
67. misma posici n AVISO Sise supera la capacidad de los generadores en vatios amperios se podr a da ar el A ADVERTENCIA El voltaje del generador podr a generador y o los dispositivos el ctricos conectados provocar descargas el ctricas o a l A quemaduras que pueden producir lesiones e NO exceda la capacidad en vatios amperios del generador __ graves o la muerte oo Consulte No sobrecargar el generador en la secci n Utilice los equipos de transferencia indicados ideales Operando para el uso deseado a fin de evitar la retroalimentaci n ya que se a sla el generador de las personas que trabajan con el suministro el ctrico Si utiliza el generador como sistema de reserva notif quelo a la compa a el ctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o receptaculos AVISO Un tratamiento inadecuado de la generador NO use un generador con cables el ctricos que est n podr a da arla y acortar su vida til malgastados rotos pelados o da ados de cualquier forma e Use el generador solamente con la finalidad para el cual NO opere el generador bajo la lluvia fue dise ado NO maneje el generador o cables el ctricos mientras e En caso de dudas sobre su uso dir jase al distribuidor est parado en agua descalzo o cuando las manos y los e
68. n Espanol 13 Caracteristicas y mandos Lea este Manual del Operario y reglas de seguridad antes de poner en marcha su generador LL Compare las ilustraciones con su generador para familiarizarse con la ubicaci n de los diversos controles y ajustes Guarde este manual para futuras consultas NY Loe nle NS cS A Interruptor Balancin Deber estar en la ON 1 posici n para darle arranque al motor Col quelo en la OFF 0 posici n para detener un motor en funcionamiento B Toma de 120 VCA 30 A para remolques Se puede usar para suministrar energ a el ctrica para cargas el ctricas de remolque de 120 VCA 30 A monofasicas 60 Hz C Disyuntores CA La tomas disponen de disyuntores de rearme por presion que protegen el generador contra sobrecargas el ctricas D Tomacorriente GFCI dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 Voltios AC a 20 Amperios monof sica de 60 Hz E Tap n de llenado de aceite Compruebe y a ada aceite de motor aqu F Tap n de vaciado de aceite Permite vaciar el aceite del motor G Conector de Tierra Consulte con el organismo responsable de la normativa vigente de conexi n a tierra 14 ns A la
69. n ratrice en marche Engines emit carbon monoxide DO NOT run in enclosed area Le moteur d gage du monoxyde de carbone NE PAS faire fonctionner dans un espace ferm Gasoline is flammable Allow engine to cool before refueling L essence est inflammable Laissez refroidir le moteur avant de remplir le r servoir High voltage DO NOT operate in wet conditions Haute tension NE PAS faire fonctionner dans un milieu d tremp Transfer switch MUST be used to connect generator to building Le commutateur de transfert DOIT tre utilis pour raccorder la g n ratrice l difice Muffler area is hot DO NOT touch of Les surfaces environnantes JU du silencieux sont chaudes NE PAS toucher AG 194984 a Equipment Description Read this manual carefully and become familiar with your generator Know its applications its limitations and any hazards involved The generator is an engine driven revolving field alternating current AC generator It was designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads The generator s revolving field is driven at about 3 600 rpm by a single cylinder engine NOTICE Exceeding generators wattage amperage Capacity could damage generator and or electrical devices connected to it e DO NOT exceed the generators wattage amperage capacity See Don t Overload Generator in the Operation
70. n a Carbon Monoxide CO safe zone See Generator Location to reduce the Risk of Carbon Monoxide Poisoning O Generator placed in a fire safe zone See Generator Location to reduce the Risk of Fire O Generator located on flat and level surface Oil and Fuel O Engine filled to proper oil level See Add Engine Oil O Fuel tank filled at or below baffle See Add Fuel O Inspect fuel lines tank cap and fittings each time before using generator DO NOT use if fuel leak or damage is found Electrical O When connecting to a buildings electrical system install listed transfer equipment See Connecting to a Building s Electrical System Electrical cords are rated for intended loads See Cord Sets and Receptacles Electrical cords do not run through doorways windows holes in ceilings walls or floors Inspect electrical cords thoroughly before each use DO NOT use if damaged O All labeled electrical cord safeties are understood and being followed oo O Operation O Start engine See Starting the Engine Operator Safety Safety Labels The generator safety labels shown below and on the next page are placed on your portable generator to draw attention to potential safety hazards A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home Only use OUTSIDE and or garage EVEN IF doors far away from windows and wi
71. nd explosive which could A cause burns fire or explosion resulting in death or serious injury WHEN ADDING FUEL e Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke 1 Clean area around fuel fill cap remove cap 2 Slowly add unleaded gasoline A to fuel tank B Be careful not to fill above the baffle C This allows adequate space for fuel expansion as shown 3 Install fuel cap and let any spilled fuel evaporate before starting engine High Altitude At altitudes over 5 000 ft 1524 m a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adjustment will cause decreased performance increased fuel consumption and increased emissions See an authorized dealer for high altitude adjustment information Operation of the engine at altitudes below 2 500 ft 762 m with the high altitude kit is not recommended 10 System Ground The generator has a system ground that
72. ndows are open doors and vents 202997 Fire Hazard Operation of this equipment may create sparks that can start fires around AA dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements 208538 Hot engine exhaust gases can cause fire Reflective exhaust Les gaz d chappement de moteur chauds peuvent causer un incendie heat can damage fuel tank causing fire Keep at least 5 ft 77 La chaleur d chappement r fl chie peut endommager le r servoir d essence et causer un incendie 152 cm clearance from any combustibles or structure Laissez un d gagement d au moins 1 52 m 5 pi autour de tous mat riaux combustibles et structures including overhead y compris au dessus A BRIGGSandSTRATTON COM WARNING MAXIMIUM FUEL Fuel is flammable and explosive WARNING AVERTISSEMENT ENEE BAFFLE which could cause burns or fire resulting in death serious injury l P T Se and or property damage Failure to read and follow these DO NOT fill fuel above baffle instructions can result in death bodily EE AAA Always allow space for fuel injury and or property damage oe 312728 L omission de lire et de suivre les instructions pourrait entra ner la mort des blessures corporelles ou des dommages mat riels Read instructions before running generator Veuillez lire les instructions avant de mettre la g
73. ne las ranuras para aire de enfriamiento y la apertura del generador Estas aperturas deber n mantenerse limpias y despejadas Mantenga limpios los componentes del generador para reducir el riesgo de sobrecalentamiento e ignici n de los residuos acumulados e Utilice un trapo h medo para limpiar las superficies exteriores AVISO Un tratamiento inadecuado de la generador podr a da arla y acortar su vida til e NO exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos e NO inserte cualquier objeto a trav s de las ranuras de enfriamiento e Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc e Puede usar una m quina aspiradora para eliminar suciedad y residuos sueltos Espa ol 19 Mantenimiento de la v lvula de combustible La v lvula de combustible est equipada con un recipiente para sedimentos un filtro y una junta t rica que deben limpiarse 1 Sit e la v lvula de combustible en la OFF 0 posici n 2 Extraiga el recipiente para sedimentos A de la v lvula de combustible Retire la junta t rica B y el filtro de la v lvula C 3 Lave el recipiente para sedimentos la junta t rica y el filtro con disolvente no inflamable S quelos perfectamente 4 Sit e el filtro y la junta t rica en la v lvula de combustible Instale el recipiente para sedimentos y apri telo firmemente 5 Sit e la v lvula de combustible en l
74. nes graves e NO toque las superficies calientes y EVITE los gases del escape a alta temperatura e Permita que el equipo se enfr e antes de tocarlo e Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior e Utilizar el motor en un terreno boscoso con maleza o cubierto de hierba constituye una infracci n al C digo de recursos p blicos de California a menos que el sistema de escape est equipado con una pantalla apagachispas de acuerdo a la definici n de la Secci n 4442 que se mantenga en buenas condiciones de funcionamiento En otros estados o jurisdicciones federales puede haber leyes similares en vigor P ngase en contacto con el fabricante el vendedor o el distribuidor del equipo original para obtener una pantalla apagachispas dise ada para el sistema de escape instalado en este motor Las piezas de recambio deben ser las mismas que las piezas originales y estar instaladas en la misma posici n Limpie o reempl ce la el apagachispas de la siguiente manera 1 Para retirar la protecci n del silenciador A de silenciador B retire los cuatro tornillos que conectan la protecci n a la m nsula del silenciador 2 Retire los cuatro tornillos que sostienen la pantalla apagachispas C 22 3 Inspeccione la pantalla y reempl cela si est rota perforada o da ada No use pantallas defectuosas Si la pantalla no est da ada limpiela con un disolvente co
75. nnected to it e DO NOT exceed the generators wattage amperage capacity See Don t Overload Generator in the Operation section e Start generator and let engine stabilize before connecting electrical loads e Connect electrical loads in OFF position then turn ON for operation e Turn electrical loads OFF and disconnect from generator before stopping generator Stopping the Engine 1 Turn OFF and unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push rocker switch to OFF 0 position WARNING Fuel and its vapors are extremely flammable and explosive which could N cause burns fire or explosion resulting in death or serious injury e DO NOT stop engine by moving choke control to CHOKE position 4 Move fuel valve to OFF 0 position 17 Don t Overload Generator Capacity You must make sure your generator can supply enough rated running and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the rated running watts of these items This is the amount of power your generator must produce to keep your items running See the table on the right 3 Estimate how many surge starting watts
76. o personal injury DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazard which if not avoided could result in death or serious injury A CAUTION indicates a hazard which if not avoided could result in minor or moderate injury NOTICE address practices not related to personal injury WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING Certain components in this product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm Wash hands after handling BRIGGSandSTRATTON COM DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents WARNING POISONOUS GAS HAZARD Engine exhaust contains carbon monoxide a poisonous gas that could kill you in minutes You CANNOT smell it see it or taste it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas e Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentia
77. onsumo de aceite Compruebe el nivel de aceite con mayor frecuencia Comprobaci n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada 8 horas de funcionamiento como m nimo Rellene si es necesario 1 Coloque el generador sobre una superficie nivelada 2 Quite el tap n de llenado de aceite y limpielo con un trapo 3 Compruebe que el aceite llega hasta el punto de desbordamiento en el orificio de llenado 4 Instale el tap n de llenado de aceite apriete firmemente Adici n de aceite del motor 1 Aseg rese de que la generador est en una superficie plana 2 Compruebe el nivel de aceite tal como se indica en la secci n Comprobaci n del nivel de aceite 3 Si es necesario vierta lentamente aceite por el orificio de llenado hasta el punto de desbordamiento en el tap n de llenado de aceite 4 Instale el tap n de llenado de aceite apriete firmemente BRIGGSandSTRATTON COM Cambio de Aceite del Motor Si est utilizando su generador bajo condiciones de extrema suciedad o polvo o en un clima demasiado caliente haga el cambio de aceite m s frecuentemente A PRECAUCI N Evite el contacto prolongado o repetido de piel con aceite usado de motor e El aceite usado del motor ha sido mostrado al cancer de la piel de la causa en ciertos animales del laboratorio e Completamente lavado expuso reas con el jab n y el agua MANTENER FUERA DEL ALCANCE DE LOS NINOS NO CONTAMINE C
78. onths warranty covers parts only Applies to Briggs amp Stratton engines only Warranty coverage of non Briggs amp Stratton engines is provided by that engine manufacturer Emissions related components are covered by the Emissions Warranty Statement In Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure For warranty service find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTRATTON COM or by calling 1300 274 447 or by emailing or writing to salesenquires briggsandstratton com au Briggs amp Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 The warranty period begins on the date of purchase by the first retail or commercial consumer Consumer use means personal residential household use by a retail consumer Commercial use means all other uses including use for commercial income producing or rental purposes Once a product has experienced commercial use it shall thereafter be considered as a commercial use product for purposes of this warranty To ensure prompt and complete warranty coverage register your product at the website shown above
79. operly 4 Assemble air cleaner cover onto base and tighten screws Service Spark Plug Changing the spark plug will help your engine to start easier and run better 1 Clean area around spark plug 2 Remove and inspect spark plug 3 Check electrode gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary see Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifications 5 Install spark plug and tighten firmly 21 Inspect Muffler and Spark Arrester The engine exhaust muffler has a spark arrester screen Inspect the muffler for cracks corrosion or other damage Inspect spark arrester screen for damage or carbon blockage Clean if carbon blockage is found or replace if damaged If replacement parts are required make sure to use only original equipment replacement parts WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury Contact with muffler area could cause burns resulting in serious injury e DO NOT touch hot parts and AVOID hot exhaust gases e Allow equipment to cool before touching e Keep at least 5 ft 1 5 m of clearance on all sides of generator including overhead e ltis a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest
80. or at www onlineproductregistration com or mail the complete registration card if provided or call 1 800 743 4115 in USA Save your proof of purchase receipt If you do not provide proof of the initial purchase date at the time warranty service is requested the manufacturing date of the product will be used to determine the warranty period Product registration is not required to obtain warranty service on Briggs amp Stratton products ABOUT YOUR WARRANTY Warranty service is available only through Briggs amp Stratton Authorized Service Dealers This warranty covers only defects in materials or workmanship It does not cover damage caused by improper use or abuse improper maintenance or repair normal wear and tear or stale or unapproved fuel Improper Use and Abuse The proper intended use of this product is described in the Operator s Manual Using the product in a way not described in the Operator s Manual or using the product after it has been damaged will not be covered under this warranty Warranty coverage will also not be provided if the serial number on the product has been removed or the product has been altered or modified in any way or if the product has evidence of abuse such as impact damage or water chemical corrosion damage Improper Maintenance or Repair This product must be maintained according to the procedures and schedules provided in the Operator s Manual and serviced or repaired using genuine Briggs amp Stratton pa
81. otor se estabilice y se caliente por dos minutos despu s del arranque 2 Ench felo y encienda la carga el ctrica deseada 120 V CA monofasico 60 Hz AVISO e NO conectar cargas de 240 V en las tomas electricas 120 V e NO conectar cargas trif sicas al generador e NO conectar cargas de 50 Hz al generador e NO SOBRECARGAR EL GENERADOR V ase No sobrecargar el generador AVISO El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conectados al mismo e NO exceda la capacidad en vatios amperios del generador Consulte No sobrecargar el generador en la secci n Operando e Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas e Conecte las cargas el ctricas en la OFF posici n luego encienda ON para su operaci n e Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador Parada del motor 1 Desconecte todas las cargas el ctricas de los tomacorrientes del panel del generador NUNCA de arranque o detenga el motor con todos los dispositivos el ctricos conectados y encendidos 2 Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Sit e el interruptor balanc n en la OFF 0 posici n ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y explosivos lo que podr a
82. p slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary e DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT e Ensure spark plug muffler fuel cap and air cleaner are in place e DO NOT crank engine with spark plug removed WHEN OPERATING EQUIPMENT e DO NOT operate this product inside any building carport porch mobile equipment marine applications or enclosure DO NOT tip engine or equipment at angle which causes fuel to spill DO NOT stop engine by moving choke control to CHOKE x position WHEN TRANSPORTING MOVING OR REPAIRING EQUIPMENT e Transport move repair with fuel tank EMPTY or with fuel shutoff valve OFF 0 e DO NOT tip engine or equipment at angle which causes fuel to spill e Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK e Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition Source because they could ignite fuel vapors WARNING e This generator does not meet U S Coast Guard Regulation 33CFR 183 and should not be used on marine applications e Failure to use the appropria
83. position Ss gt SED PE E Tr 5 Grasp recoil handle and pull slowly until slight resistance is felt Then pull rapidly one time only to start engine e fengine starts proceed to step 7 e If engine fails to start proceed to step 6 WARNING Starter cord kickback rapid retraction will pull hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury e When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback e NEVER start or stop engine with electrical devices plugged in and turned on 16 6 Move choke lever to HALF choke position and pull recoil handle twice e lf engine fails to start repeat steps 5 thru 7 7 Slowly move choke lever to RUN I 1 position If engine falters move choke lever to HALF choke position until engine runs smoothly and then to RUN position NOTICE f engine floods place choke lever in RUN position and crank until engine starts NOTICE f engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device If so oil must be at proper level for engine to start WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a
84. provocar quemaduras incendios o amp amp as como lesiones graves o incluso la muerte e NO coloque el estrangulador en la posici n CHOKE para parar el motor 4 Gire la v lvula de combustible hasta la OFF 0 posici n Espa ol 17 No sobrecargar el generador Capacidad Debe asegurarse de que su generador puede proveer los suficientes vatios de potencia continua vatiaje nominal y vatios de salida para los elementos que desee alimentar al mismo tiempo Siga estos sencillos pasos 1 Seleccione los elementos que quiere alimentar al mismo tiempo 2 Sume la potencia nominal de esos elementos Esa es la cantidad de energ a que su generador debe producir para mantener sus elementos en funcionamiento Consulte la tabla de la derecha 3 Calcule cu ntos vatios de salida necesitar La potencia de salida se refiere al corto arranque de energ a que se necesita para arrancar herramientas o dispositivos a motor como una radial o un refrigerador Como no todos los motores arrancan al mismo tiempo el total de vatios de salida puede calcularse a adiendo s lo el elemento con la potencia de salida m s alta al total de vatios de potencia continua que obtuvimos en el paso 2 Ejemplo Vatios de funcionamiento potencia nominal 1200 2100 Frigor fico 2200 Ventilador del 2350 Nono 75 Herramienta o aparato el ctrico Vatios de arranque pico adicionales Bomba del pozo de agua Tota
85. que no sean de automoci n puede encargarse del mantenimiento la sustituci n y la reparaci n de los dispositivos y sistemas de control de emisiones No obstante para realizar la revisi n gratuita de control de emisiones deber acudir a un distribuidor autorizado por el fabricante V ase Garant a de emisiones Mantenimiento del generador El mantenimiento del generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve hojas o cualquier otro material extra os AVISO NO utilice agua u otros l quidos para limpiar el generador Los l quidos pueden penetrar en el circuito de combustible del motor y provocar p rdidas de rendimiento o fallos Asimismo si penetran l quidos en el generador a trav s de las ranuras del aire de refrigeraci n parte del l quido puede permanecer en los huecos y rendijas del aislamiento del devanado del rotor y del estator El l quido y la acumulaci n de suciedad en los devanados internos del generador pueden reducir la resistencia del aislamiento Limpieza Limpie a diario o antes de cada uso los residuos acumulados en el generador Mantenga limpias las conexiones los muelles y los mandos Limpie todo resto de combustible de la zona que rodea al silenciador y de detr s del mismo Inspeccio
86. r on this engine is low emission lt is equipped with a non adjustable idle mixture valve Top speed has been set at the factory If adjustment is required see a Briggs amp Stratton authorized dealer CAUTION Excessively high operating speeds could result in minor injury Excessively low speeds impose a heavy load e DO NOT tamper with governor spring links or other parts to increase engine speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way BRIGGSandSTRATTON COM Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than 30 days use the following guidelines to prepare it for storage Generator Storage e Clean the generator as outlined in Cleaning in the Maintenance section e Check that cooling air slots and openings on generator are open and unobstructed Long Term Storage Instructions Fuel can become stale when stored over 30 days Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts To keep fuel fresh use Briggs Stratton Advanced Formula Fuel Treatment amp Stabilizer available wherever Briggs amp Stratton genuine service parts are sold There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions Run the en
87. ra el almacenamiento 1 NO guarde combustible de una temporada a otra a menos que lo haya tratado como se indica en la secci n Almacenamiento Para Periodos Prolongados 2 Cambie el contenedor de combustible si este empieza a oxidarse El combustible contaminado provocar problemas en el motor 3 Sies posible guarde la unidad en un espacio interior y prot jala del polvo y la suciedad 4 Cubra la unidad con una funda adecuada que no retenga la humedad ADVERTENCIA Las fundas para almacenamiento podr an provocar incendios y producir lesiones graves o incluso la muerte e NO coloque una cubierta encima de un generador caliente e Deje que la unidad se enfr e lo suficientemente antes de que le coloque la cubierta 5 Almacene el generador en una zona limpia y seca Espa ol 23 Resoluci n de problemas Problemo El motor est funcionando pero no existe salida de AC disponsible El motor funciona bien sin carga pero funciona mal cuando se le contectan cargas El motor no se enciende se enciende y funciona mal o se apaga en pleno funcionamiento Al motor le hace falta potencia El motor no funciona continuamente o se detiene Causa El interruptor autom tico de circuito est abierto Conexi n mal o defectuosa del juego de cables El dispositivo conectado est da ado Aver a en el generador Corto circuito en una de las cargas
88. ralia nuestros productos est n cubiertos por garant as ineludibles de acuerdo con la legislaci n sobre consumo de este pa s Tiene derecho a un recambio o devoluci n en caso de aver a grave y a una compensaci n por las posibles p rdidas o da os razonables previsibles Asimismo si la ver a no es grave tiene derecho a que se reparen o reemplacen los productos si no tienen una calidad aceptable Para servicio de garant a localice al distribuidor de servicio autorizado m s cercano con nuestro mapa en BRIGGSandSTRATTON COM llame al 1300 274 447 o bien env e un correo electr nico a salesenquires briggsandstratton com au o escriba a Briggs amp Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 El per odo de garant a comienza en la fecha de compra del primer consumidor o usuario comercial final Uso particular significa uso dom stico residencial personal por un consumidor minorista Uso comercial significa los dem s usos lo que incluye el uso para prop sitos comerciales generar ingresos o alquiler Una vez que el producto se haya usado para fines comerciales de ah en adelante se considerar uso comercial a efectos de esta garant a A fin de garantizar una pronta y completa cobertura de la garant a registre su producto en el sitio web que se muestra arriba o en www onlineproductregistration com o env e por correo la tarjeta de registro diligenciada si se suministra o llame al 1 800 743 4115 en los EE
89. rnia a menos que el sistema de escape est equipado con una pantalla apagachispas de acuerdo a la definici n de la Secci n 4442 que se mantenga en buenas condiciones de funcionamiento En otros estados o jurisdicciones federales puede haber leyes similares en vigor P ngase en contacto con el fabricante el vendedor o el distribuidor del equipo original para obtener una pantalla apagachispas dise ada para el sistema de escape instalado en este motor ADVERTENCIA Las chispas involuntarias podr an provocar incendios o A electrocuci n que pueden provocar lesiones graves o la muerte CUANDO AJUSTE O HAGA REPARACIONES A SU MAQUINA GENERADOR e Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR e Utilice un comprobador de buj as homologado e NO comprueba la chispa sin la buj a instalada PRECAUCI N Las velocidades de funcionamiento excesivamente altas podrian provocar lesiones leves Las velocidades excesivamente bajas incrementan la carga de trabajo e NO intente alterar el resorte las conexiones y otras partes del regulador para incrementar la velocidad del motor El generador suministra la frecuencia y el voltaje nominales correctos cuando funciona a una velocidad controlada NO modifique al generador en ninguna forma Las piezas de recambio deben ser las mismas que las piezas originales y estar instaladas en la
90. rts or equivalent Damage caused by lack of maintenance or use of non original parts is not covered by warranty Normal Wear and Tear Like most mechanical devices your unit is subject to wear even when properly maintained This warranty does not cover repairs when normal use has exhausted the life of a part or the equipment Maintenance and wear items such as filters belts cutting blades and brake pads except engine brake pads are not covered by warranty due to wear characteristics alone unless the cause is due to defects in material or workmanship Stale or Unapproved Fuel In order to function correctly this product requires fresh fuel that conforms to the criteria specified in the Operator s Manual Engine or equipment damage caused by stale fuel or the use of unapproved fuels such as E15 or E85 ethanol blends is not covered by warranty Other Exclusions This warranty excludes damage due to accident abuse modifications alterations improper servicing freezing or chemical deterioration Attachments or accessories that were not originally packaged with the product are also excluded There is no warranty coverage on equipment used for primary power in place of utility power or on equipment used in life support applications This warranty does not include used reconditioned second hand or demonstration equipment or engines This warranty also excludes failures due to acts of God and other force majeure events beyond the manufacturer s contro
91. s control service the work must be performed by a factory authorized dealer See the Emissions Warranty Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTICE DO NOT use water or other liquids to clean generator Liquids can enter engine fuel system causing poor performance and or failure to occur In addition if liquid enters generator through cooling air slots some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Cleaning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean accumulated debris from inside and outside the generator Keep the linkage spring and other engine controls clean Keep the area around and behind the muffler free from any combustible debris Inspect cooling air slots and openings on generator These openings must be kept clean and unobstructed Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris e Use a damp cloth to wipe exterior surfaces clean
92. s de Briggs amp Stratton autorizados en todo el mundo proporcionando un servicio de calidad Tambi n puede ponerse en contacto con Atenci n al Cliente de Briggs Stratton llamando al 800 743 4115 o por Internet en BRIGGSandSTRATTON COM Generador Motor N mero de Modelo N mero de Modelo Revisi n N mero de Tipo N mero de Serie N mero de C digo Fecha de compra Tabla de Contenido Lista de control para una operaci n segura 3 Seguridad de operario 4 Montaje 7 gm Eff 9 Caracter sticas y mandos 14 Operando 16 Mantenimiento 19 Resoluci n de problemas 24 GORA eco io a VA Oe ek ed 25 Especificaciones del producto 26 Partes de servicio comun 26 Copyright 2014 Briggs amp Stratton Power Products Group LLC Milwaukee WI USA Reservados todos los derechos BRIGGS amp STRATTON POWER PRODUCTS es una marca registradas de Briggs amp Stratton Corporation Milwaukee WI USA 2 BRIGGSandSTRATTON COM Lista de control para una operaci n segura Para la operaci n segura del generador port til es necesario que se completen las siguientes tareas Alarma de mon xido de carbono CO O Las alarmas de mon xido de carbono CO deben estar en buenas condiciones de funcionamiento Alarma de humo O Las alarmas de humo deben estar en buenas condiciones de funcionamiento Ubi
93. si como lesiones graves o incluso la muerte CUANDO ANADA COMBUSTIBLE O VAC E EL DEPOSITO e DETENGA el motor del generador y d jelo enfriar durante al menos 2 minutos antes de quitar el tap n de combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene o vac e el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n Compruebe frecuentemente que las l neas de combustible el tanque el tap n y los accesorios no est n rotos o tengan fugas C mbielos si es necesario e NO encienda un cigarrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO e Compruebe que la buj a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados e NO arranque el motor sin la buj a instalada CUANDO OPERE EL EQUIPO e NO utilice este producto en el interior de un edificio cochera porche equipo m vil taller de aplicaciones navales o recinto NO incline el motor o el equipo de tal manera que la combustible se pueda derramar NO coloque el estrangulador en la posici n CHOKE para parar el motor CUANDO TRANSPORTE MOVER O REPARE EL EQUIPO e Transporte mover o repare el equipo con el tanque
94. sta el nivel correcto o sit e el generador en una superficie plana Limpie o reemplace el depurador de aire Limpie o cambie el filtro de combustible Ll nelo con combustible fresco Drene el tanque de gasolina ll nelo con combustible fresco Conecte el cable a la buj a Reemplace la buj a Drene el tanque de gasolina ll nelo con combustible fresco Abra por completo el cebador y haga girar el motor Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Vea No Sobrerecarque Generador Reemplace el filtro de aire Limpie o cambie el filtro de combustible Contacte el distribuidor de servicio autorizado Limpie o cambie el filtro de combustible 24 BRIGGSandSTRATTON COM NORMAS DE GARANT A DE PRODUCTOS BRIGGS amp STRATTON enero de 2014 GARANT A LIMITADA Briggs Stratton se compromete a que durante el per odo de garant a especificado a continuaci n reparar o sustituir de manera gratuita cualquier pieza con defectos de material o fabricaci n o de ambos El comprador deber correr con los gastos de transporte del producto que env e para reparaci n o reemplazo al amparo de esta garant a Esta garant a tiene vigencia y est sujeta a las condiciones que se establecen m s adelante Para el servicio de garant a busque el distribuidor de servicio
95. te U S Coast Guard approved generator could result in death or serious injury WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury e Use listed transfer equipment suitable for the intended use to prevent backfeed by isolating generator from electric utility workers When using generator for backup power notify utility company Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaust heat gases could ignite combustibles structures or damage la A fuel tank causing a fire resulting in death or serious injury Contact with muffler area could cause burns resulting in serious injury DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 ft 1 5 m of clearance on all sides of generator including overhead It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest covered brush covered or grass covered
96. ubierta Desh gase del filtro viejo apropiadamente 4 Arme la cubierta m s limpia a rea en la base y apriete los tornillos Servicio del buj a Cambie la buj a ayudar a su motor a arrancar m s f cilmente y funcionar mejor 1 Limpie la zona de alrededor de la buj a 2 Retire e inspeccione la buj a 3 Compruebe la separaci n del electrodo con un calibrador de alambre y ajuste el espacio de la buj a a la medida recomendada si fuera necesario v ase Especificaciones 4 Cambie la buj a si los electrodos est n picados o quemados o si la porcelana est agrietada Utilice la buj as de repuesto recomendada Consulte Especificaciones 5 Instale la buj a y apriete firmemente Espa ol 2 Inspeccione el silenciador y la pantalla apagachispas El silenciador de escape del motor tiene una pantalla antichispas Inspeccione el silenciador por si presenta fisuras corrosi n u otros da os Revise la pantalla antichispas en busca de da os u obstrucciones de carb n Limpie si se encuentra una obstrucci n de carb n o reempl celo si est da ado Si debe reemplazar alguna pieza utilice solo repuestos originales ADVERTENCIA Los gases y el calor de escape podr an inflamar los materiales combustibles y las estructuras o da ar el dep sito de combustible y provocar incendios as como lesiones graves o incluso la muerte El contacto con la zona del silenciador podr a producir quemaduras y lesio
97. ucciones del fabricante Las alarmas de humo no pueden detectar el gas de mon xido de carbono NO utilice este producto dentro de casas garajes s tanos entresuelos cobertizos o en otros espacios parcialmente cerrados a n si utiliza ventiladores o deja las puertas y ventanas abiertas para favorecer la ventilaci n El mon xido de carbono puede acumularse r pidamente en estos espacios y perdurar ah durante horas aun despu s de que este producto se haya apagado SIEMPRE coloque este producto en direcci n del viento y dirija el escape del motor en sentido contrario alos espacios habitados Si comienza a sentirse mal mareado o d bil cuando use este producto busque aire puro DE INMEDIATO Acuda a un m dico Es posible que se haya envenenado con mon xido de carbono A ADVERTENCIA El retroceso repliegue r pido del cable del arrancador impedir que el usuario suelte el cable a tiempo y tirar de su mano y brazo hacia el motor lo que podr a provocar fracturas contusiones o esguinces as como lesiones graves e Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso e NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y A explosivos lo que podria provocar quemaduras incendios o explosiones a
98. verned speed DO NOT modify generator in any way NOTICE Exceeding generators wattage amperage capacity could damage generator and or electrical devices connected to it e DO NOT exceed the generators wattage amperage capacity See Don t Overload Generator in the Operation section e Start generator and let engine stabilize before connecting electrical loads e Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator NOTICE improper treatment of generator could damage it and shorten its life e Use generator only for intended uses e f you have questions about intended use ask dealer or contact local service center e Operate generator only on level surfaces e DO NOT expose generator to excessive moisture dust dirt or Corrosive vapors e DO NOT insert any objects through cooling slots e f connected devices overheat turn them off and disconnect them from generator e Shut off generator if electrical output is lost equipment sparks smokes or emits flames unit vibrates excessively BRIGGSandSTRATTON COM Assembly Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel If you have any problems with the assembly of your generator please call the generator helpline at 1 800 743 4115 lf calling for assistance please have t
99. y or weak while using this product get to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning 11 EXAMPLE OF LOCATION TO REDUCE THE RISK OF CARBON MONOXIDE POISONING y o CO Alarm in Living Areas KEEP FAR AWAY Only use OUTSIDE Direct exhaust AWAY and FAR AWAY from from windows doors windows doors and vents and vents DO NOT OPERATE IN ANY OF THE FOLLOWING LOCATIONS Basement Crawlspace and exhaust directed towards windows doors and vents BRIGGSandSTRATTON COM Operation Location of Portable Generator to REDUCE THE RISK OF FIRE WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury e Portable generator must be at least 5 ft 1 5 m from any structure overhang trees windows doors any wall opening shrubs or vegetation over 12 inches 30 5 cm in height DO NOT place portable generator under a deck or other type of structure that may confine airflow Smoke alarm s MUST be installed and maintained indoors according to the manufacturer s instructions recommendations Carbon monoxide alarms cannot detect smoke DO NOT place portable generator in manner other than shown EXAMPLE OF LOCATION TO REDUCE THE RISK OF FIRE LL 4 5 ft 1 5 m min gt Direct exhaust AWAY from windows doors and
100. you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Tool or Running Additional Appliance Rated Watts Starting Surge Watts Water Well 1200 2100 Pump Refrigerator 2200 Furnace Fan 2350 Television Light 75 Watts 3275 Total 2350 Highest Running Watts Starting Watts Total Rated Running Watts 3275 Highest Additional Surge Watts 2350 Total Generator Output Required 5625 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load O1 18