Home
INST SHT KSF RJ5210105
Contents
1. WALL BRACKET WB WALL OR WOOD POLE MOUNTING WW figure 2 figure 3 POLE MOUNTING Anchors 4 by others figure 1 te KSF Arm mounted Rectilinear wg ae i eainer prog Full cutoff Lighting calling on ja both sides Walor Pole of the wall plate by others Fasteners by others DELIVERY Upon receipt of fixture and accessories packed separately thoroughly inspect for any freight damage All damage should be reported to the delivery carrier Compare the catalog description listed on the packing slip with the fixture label on the inside of the housing to be sure you have received the correct merchandise 1 POLE see Figure 1 Insert the mounting plate inside pole or tenon adapter aligning the three 3 mounting holes in plate with the three 3 mounting holes provided on pole Slide threaded rods through top and bottom mounting holes in poles and start to thread the rods into the matching holes in the mounting plate A few turns Is all that is needed Place one of the enclosed gaskets over threaded rods and against pole WALLandWOOD CAUTION APPLY A CONTINUOUS BEAD OFWEATHER PROOFCAULKING BETWEEN MOUNTING PLATE AND WALLTO ENSURE WEATHER TIGHT INTEGRITY OF ELECTRICAL COMPONENTS Wall or Wood Pole Mounting Place mounting plate on mounting surface For WB see Figure 2 secure the mounting plate to the wall with four 4 minimum 1 2 to maximum 5 8 fasteners by others For WW see Figur
2. Permet le choix de tension Pour c bler ce ballast d abord identifier la tension de secteur Puis s lectionner le conducteur ad quat du luminaire enlever le sertissage et connecter au conducteur de l alimentation Connecter le fil COM de l appareil au fil neutre de l alimentation pour tous les appareils avec ballast multiprises Prot ger individuellement chaque conducteur inutilis de l appareil Gasket 3 required GUIDE DE D PANNAGE Handhole Dans le cas d un fonctionnement inad quat de l appareil v rifier d abord ce qui suit cover La lampe install e est ad quate L appareil est c bl correctement Gd La lampe n est pas grill e ou d fectueuse Ka L appareil est correctement mis la terre Screw La tension de secteur l alimentation l unit est ad quate 2 required Si apr s avoir effectu toutes ces v rifications l appareil ne fonctionne pas ad quatement veuillez contacter votre repr sentant Lithonia Lighting Sateen ounting Plate 2 required figure 4 Lithonia Lighting Outdoor fa LITHONIA LIGHITING One Lithonia Way Conyers GA 30012 Part Number RJ5210105 Rev D AnAcultyBrands Company Phone 800 279 8041 Fax 770 918 1209 Revision Date 11 15 10 2001 Acuity Brands Lighting Inc wwwiithonia com All Rights Reserved Rev 11 10
3. ajust au poteau ou au mur 4 Acheminer les fils d alimentation et les conducteurs de l appareil dans le bras de montage ou le dessus du poteau Compl ter le c blage par le couvercle de la trappe d acc s ou le dessus du poteau en suivant les directives de c blage Poser la lampe selon les directives et remettre le cadre de lentille Fermer le couvercle de la trappe d acc s et fixer s il y a lieu INSTALLATION DE LA LAMPE Avant d installer la lampe dans l appareil s assurer que le type de lampe et la puissance sont appropri s D gager le fermoir du cadre de porte de la lentille en le tournant dans le sens inverse des aiguilles d une montre au moyen d un tournevis Soulever le cadre en soutenant l unit en position ouverte Visser solidement la lampe dans la douille la d visser d un ou deux tours puis revisser pour assurer une bonne installation Fixer le fermoir du cadre en le tournant dans le sens horaire jusqu ce que bien serr ROTATION DES COMPOSANTS OPTIQUES D gager les vis de fermeture du bo tier pour ouvrir le montage lentille Retirer le plateau du r flecteur de son support La rotation du bloc optique s effectue en segments de 90 degr s afin d obtenir l effet d clairage voulu Une fois la nouvelle orientation choisie repousser le plateau sur son support S assurer que tous les pivots rotule situ s sur le plateau du r flecteur s engagent au support de montage Fermer le montage lentille BALLAST MULTIPRISES TB
4. Installation Instructions KSF READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS A WARNING To reduce the risk of death injury or property damage from fire electric shock cuts abrasions falling parts and other hazards e Service of the equipment must be performed by qualified service personnel e Installation and maintenance must be performed by a person familiar with the construction and operation of this product and any hazards involved All applicable codes and ordinances must be followed Read this document before installing servicing or maintaining this equipment or installing a lamp These instructions do not cover all installation service and maintenance situations If your situation is not covered or if you do not understand these instructions or additional information is required contact Lithonia Lighting or your local Lithonia Lighting Distributor Read and follow all warnings and instructions provided by the lamp manufacturer A WARNING Before installing servicing or maintaining this equipment follow these general precautions To reduce the risk of electrocution e Make sure the equipment is properly grounded Always de energize the circuit and or equipment before connecting to disconnecting from or servicing the equipment To reduce the risk of fire e Keep material away that can burn from hot lamp e Make sure lamps ar
5. e lead marked COM should be connected to the neutral supply lead for 120 or 277 For 208 or 240 connect the other incoming hot leg to the fixture lead marked COM Be sure to cap off all unused fixture leads individually TROUBLESHOOTING If this fixture fails to operate properly check to make sure The correct lamp is properly installed eThe fixture is wired correctly eThe lamp is not faulty The fixture is grounded correctly eThe line voltage at the fixture is correct Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Part Number RJ5210105 Rev D VA LITHONIA LIGHTING a 800 279 8041 Fax 770 918 1209 Revision Date 11 15 10 www ilinonia com 4n AcuityGrands Compay Outils requis Tournevis a pointe cruciforme ou lame droite cl de 9 16 po WALL BRACKET WB WALL OR WOOD POLE MOUNTING WW figure 2 figure 3 POLE MOUNTING Anchors 4 by others figure 1 ie KSF Arm mounted Rectilinear Full cutoff Lighting Weather proof 36 caulking on se Wallor Pole both sides of the wall Fasteners plate by others by others INSTALLATION MONTAGE DE L APPAREIL S assurer qu aucune pi ce ne reste dans la bo te avant de la jeter 1 POTEAU Ins rer la plaque de montage dans le poteau ou l adaptateur de tenon aligner les trois 3 trous de la plaque aux trois 3 trous du poteau Glisser les tiges filet es au travers les trous du haut et du bas et commencer visser le
6. e 3 mark first and fifth holes of plate remove mounting plate and drill 5 8 hole at marked locations minimum of 3 4 to accept fixture mounting rods secure mounting plate to mounting surface fasteners not provided using second and fourth holes Insert the two threaded fixture mounting rods into mounting plate and turn to secure 2 The mounting arm is cut with a 2 angle on one end to pitch fixture slightly upward In order to mount arm properly follow the instructions on the label that is on the arm To mount arm slide arm over threaded rod using the bolt guides inside arm Again checkto see thatlabelis inthe correct place Place remaining gasket over threaded rods and against mounting arm NOTE KSF3 requires an additional external mounting plate and gasket parts in fixture carton to be placed onto the threaded rods between the mounting arm gasket and the fixture housing as shownin Hanchole Figure 4 d 3 To simplify installation remove lens frame from fixture To mount fixture align the gasket to mounting holes between fixture housing and mounting bracket Insert threaded rods into fixture being carefulto align gasketing between fixture housing and mounting arm Installsplitlockwashers quired ie and cap nuts furnished on threaded rod and tighten securely During this process be sure the ne fixture is mounted straight on pole or wall Mounting Plate figure 4 4 Pull both supply and fixture leads into mounting arm
7. e correctly installed e Use supply conductors with a minimum installation temperature rating as specified on equipment To reduce the risk of personal injury from cuts abrasions or falling parts e Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton handling and maintaining this equipment Do not use abrasive materials glass cleaners or other solvents on reflector or lens These substances may damage equipment and cause parts to eventually break and fall Do not install a damaged fixture CAUTION Observe lamp manufacturer s recommendations and restrictions on lamp operation including but not limited to ballast type burning position replacement and cycling Use only lamps that comply with applicable ANSI standards NOTICE lf lamp is marke Hg it contains mercury Follow disposal laws See www lamprecycle org Lithonia Lighting a division of Acuity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of this product SAVE THESE INSTRUCTIONS Lithonia Lighting Outdoor a LITHONIA LIGHITING One Lithonia Way Conyers GA30012 Part Number RJ5210105 Rev D An AcuityGrands Company Phone 800 279 8041 Fax 770 918 1209 Revision Date 11 15 10 www lithonia com Installation Instructions Tools Required Straight blade screwdriver and 3 4 open end wrench for wall or wood pole also need a drill with 5 8 bit KSF
8. or pole top Complete the wiring through the hand hole access cover or inthe pole top following instruction listed under wiring fixture Lamp the fixture following lamping instructions and install lens frame Swing hand hole cover into closed position and secure when applicable LAMP INSTALLATION AND RE INSTALLATION Verify the lamp is the correct source and wattage Screw the lamp securely into the socket back it out one or two turns then screw lamp back in making sure it is secure and properly seats lamp in the socket Lamp at end of life should be promptly replaced Failure to do so may cause damage to components OPTICAL ROTATION WARNING Burn Risk Ensure lamp cools before performing maintenance Open door assembly Remove lamp Gently pull reflector away from reflector skirt Rotate optical assembly in 90 degree increments to desired light output as indicated by light distribution arrow on reflector Insert reflector assembly back into opening by lining up the four ball studs and their receptacles and gently pushing down until all four ball studs click into place you will hear an audible click Reinstall lamp see above Close door assembly Multi tap Ballast TB The multi tap ballast will be prewired for 277V at the factory This option offers multi voltage capability First determine the correct line voltage Then select the corresponding fixture voltage lead remove the crimped cap and connect to the supply voltage lead The fixtur
9. s tiges dans les trous correspondants de la plaque de montage Quelques tours suffiront Placer un des joints d tanch it fournis sur les tiges Fixer la plaque de montage au mur ou au poteau en bois l aide d une fixation d un diam tre de 1 2 po min 5 8 po max par d autres Percer des trous de passage d au moins 9 16 po dia et 1 2 po de profondeur pour les tiges filet es installer au travers les trous de la plaque de montage Visser partiellement les tiges dans les trous correspondants de la plaque quelques tours seront suffisants Placer un des joints fournis sur les tiges filet es et contre la plaque de montage 2 Le bras de montage est coup angle de 2 une extr mit afin d orienter le luminaire vers le haut Suivre les directives de l tiquette cet effet Pour le montage glisser le bras sur la tige filet e l aide des guides l int rieur du bras S assurer que l tiquette est au bon endroit Poser le joint d tanch it restant sur les tiges filet es et le bras 3 Enlever le cadre de lentille du luminaire pour faciliter l installation Pour monter l appareil aligner le joint d tanch it sur les trous entre le bo tier et le support de montage Ins rer les tiges filet es dans l appareil s assurer d aligner le joint entre le bo tier et le bras de montage Installer les rondelles freins et les crous borgnes fournis sur la tige filet e et bien serrer S assurer que le luminaire est droit et bien
Download Pdf Manuals
Related Search
Related Contents
トリシティ125 取扱説明書ダウンロード White Outdoor Roto Boss 850 215-418-190 User's Manual Knock ou le triomphe de la médecine_DDP_001 Types 95L, 95BL, et 95LD - Welcome to Emerson Process User Manual Rupture mode d`emploi Adding a VMS Server - Ameritech Systems Corp エコアシストチェア Réglementations Copyright © All rights reserved.
Failed to retrieve file