Home

Z-12089 ASM Rev 2 - Juno Lighting Group

image

Contents

1. AccuLite Main Street Z 12089 Commercial and Industrial Lighting Decorative Street Lighting Series ASM1 Installation Instructions Rev 2 15 05 2008 Important Safeguards WARNING When using electrical equipment Disconnect Power basic safety precautions should always be used e Always disconnect power during installation and maintenance including the following This product must be installed in accordance O Assemble Luminaire with the applicable installation code by a Remove castle nuts and lock washers person familiar with the construction and aae operation of the product and the hazards en involved 2 Remove top casting READ AND FOLLOW ALL SAFETY E INSTRUCTIONS Remove spacer Follow disposal laws a See www lamprecycle org Install reflector A Refractor Louver or Glass Refractor Hg Mark means lamp contains mercury Louver e Louver is factory installed Insert glass refractor in factory installed collar install lamp Type III Glass Refractor e Type Ill suffix GR3 glass refractors must be installed with the STREET SIDE facing the roadway The street side locator is molded into the top of the refractor Check Voltage e If fixtures are supplied with Multi Tap ballasts Ensure correct lead is used on multi voltage ballasts e Connect wires to proper voltage e Individually cap all unused leads O Secure Luminaire e Tighten set screws around t
2. ce Lamp e Voltage Line or ballast output voltage too Low Check line voltage at the fixture Check open circuit voltage Courte vie utile de la lampe Lampe ou ballast incorrect e Examinez les tiquettes car le ballast et la lampe doivent tre appari s Cycle de fonctionnement e La dur e de la lampe est bas e sur un cycle d utilisation de 10 heures par mise en service Lampe d fectueuse e Remplacez la lampe Tension voltage e La tension de sortie de la ligne ou du ballast est trop basse V rifiez la tension de la ligne au luminaire V rifiez la tension a circuit ouvert Gu a de Localizaci n y Resoluci n de Problemas Primero verifique el posible da o f sico de la luminaria Si parece estar en buenas condiciones siga los siguientes pasos Advertencia Desconecte la corriente Siempre desconecte la corriente el ctrica durante la instalaci n o el mantenimiento La l mpara no enciende o tarda en encender La l mpara est floja e Desconecte la corriente luego regrese y aj stela Voltaje e El voltaje de l nea o el de la salida del balasto es demasiado bajo Verifique el voltaje de linea en el aparato Verifique el voltaje en el circuito abierto Falla en el circuito arrancador e Use una l mpara probada como buena para confirmar El balasto no funciona e Verifique la continuidad del circuito o JUNO LIGHTING GROUP D sovare D Temperatura ambien
3. ectez le courant Vous devez toujours d brancher le courant lectrique durant l installation et l entretien La lampe refuse de s allumer ou d marre lentement La lampe est desserr e Coupez le courant d vissez la lampe puis resserrez la Tension voltage e La tension de sortie de la ligne ou du ballast est trop basse V rifiez la tension de la ligne au luminaire V rifiez la tension a circuit ouvert D faillance du circuit de l amorceur e Employez une lampe que vous savez tre en bon tat pour confirmer le probl me e Lampe ou ballast incorrect Examinez les tiquettes car le ballast et la lampe doivent tre appari s C blage e V rifiez le c blage Est il desserr Est il connect au bon conducteur s il s agit d un ballast prises multiples Temp rature ambiante e V rifiez les puissance nominales du ballast et de la lampe par rapport la situation existante Fin de la vie utile de la lampe e Remplacez la par une lampe neuve e Signes visibles de la fin de sa vie utile ce stade l une lampe SHP s allume et s teint constamment Dans le cas d une lampe HM elle change vraiment de couleur Ballast qui ne fonctionne pas e V rifiez la continuit du circuit Short Lamp Life e Wrong lamp or ballast Check labels lamp and ballast must match Operating Cycle Lamps life is based on a 10 hour per start operating cycle e Faulty Lamp Repla
4. he base of the luminaire 4 SAVE THESE INSTRUCTIONS JUNO LIGHTING GROUP Technical Support 888 387 2212 DO sauared 1300 S Wolf Road Des Plaines Illinois 60017 219 Shoemaker Street Kitchener Ontario N2E 3B3 220 Chrysler Drive Brampton Ontario L6S 6B6 AccuLite Trouble Shooting Guide First check for physical damage to the luminaire If it appears to be in good condition follow the following steps Warning Disconnect power Always disconnect power during installation and maintenance Lamp does not start or is slow to start Lamp is Loose e Turn power off then back off and retighten Voltage e Line or ballast output voltage too Low Check line voltage at the fixture Check open circuit voltage Starter Circuit Failure Use known good lamp to confirm Ambient Temperature e Check ballast and lamp ratings against existing conditions Ballast Not Operating Wrong lamp or ballast e Check labels lamp and ballast must match Wiring e Check wiring wiring loose connected to the correct lead in multi tap ballasts End of Lamp Life e Replace with new lamp e Visible Signs of End of Life HPS lamps will cycle on and off at this stage of life MH lamps experience severe colour shift e Check circuit continuity Guide de d pannage Voyez d abord si le luminaire a subi des dommages physiques S il semble en bon tat vous devriez proc der comme suit Avertissement D conn
5. match e Operating Position Metal Halide lamps may be position oriented Check lamp specification Replace lamp with correct orientation e Line Voltage Varies Use recording volt meter to check La lampe s allume et s teint constamment Faible rendement de la lampe Fin de sa vie utile Condensateur o Remplacez la par une lampe e Assurez vous qu il est en bon tat neuve Les lampes SHP s allument Tension voltage et s teignent sans cesse La tension de sortie de la Lampe ou ballast incorrect ligne ou du ballast est e Examinez les tiquettes car trop basse l le ballast et la lampe doivent V rifiez la tension de la tre appari s ligne au luminaire V rifiez la tension circuit e Position de fonctionnement ouvert Les lampes halo de m tallis peuvent tre orient es V rifiez les sp cifications de la lampe Corrigez l orientation de la lampe La tension de la ligne varie e Servez vous d un voltm tre enregistreur pour la v rifier La l mpara se enciende y se apaga intermitentemente L mpara de bajo rendimiento Voltaje e El voltaje de l nea o el de la salida del balasto es demasiado bajo Verifique el voltaje de l nea en el aparato L mpara agotada e Reemplace con una l mpara nueva Las l mparas HPS se encienden y apagan intermitentemente Verifique el voltaje en el circuito abierto L mpara o balasto equivocado e Verifique las e
6. te e Verifique los valores del balasto y de la l mpara contra las condiciones existentes L mpara o balasto equivocado e Verifique las etiquetas la l mpara y el balasto deben coincidir Cableado e Verifique que el cableado Hay cables perdidos est conectado al cable correcto en los balastos multivoltaje L mpara agotada e Reemplace con una l mpara nueva e Signos visibles de agotamiento Las l mparas HPS se encienden y se apagan intermitentemente en esta etapa de vida Las l mparas MH experimentan un cambio importante de color Technical Support 888 387 2212 Corta vida til de la l mpara L mpara o balasto equivocado e Verifique las etiquetas la l mpara y el balasto deben coincidir e Ciclo de funcionamiento e La vida de las l mparas est basada en un ciclo de funcionamiento de 10 horas por cada encendido L mpara defectuosa e Reemplace la l mpara Voltaje e El voltaje de l nea o el de la salida del balasto es demasiado bajo Verifique el voltaje de linea en el aparato Verifique el voltaje en el circuito abierto Lamp Turns on amp Off Cycling Low Lamp Output e End of Life e Capacitor e Replace with new lamp Check for failure HPS lamps will cycle e Voltage Line or ballast output voltage too Low Check line voltage at the fixture Check open circuit voltage on and off e Wrong lamp or ballast e Check labels lamp and ballast must
7. tiquetas la l mpara y el balasto deben coincidir Posici n de funcionamiento e Las l mparas de Halogenuro Met lico pueden ser de posici n orientada Verifique la especificaci n de la l mpara Reemplace la l mpara en la orientaci n correcta Capacitor e Verifique posible falla El voltaje de l nea var a e Para verificar utilice la lectura de un voltimetro 1300 S Wolf Road Des Plaines Illinois 60017 219 Shoemaker Street Kitchener Ontario N2E 3B3 220 Chrysler Drive Brampton Ontario L6S 6B6

Download Pdf Manuals

image

Related Search

Related Contents

  SteriPEN User's Guide Instructions for Using SteriPEN Quick Start  210HP_Bead_Breaker    New Product Release CL2AD4-B CL2DA2-B  こんなときは?  MTW-746TWIN_ENG - Besøg masterpiece.dk  USER MANUAL  

Copyright © All rights reserved.
Failed to retrieve file