Home

INSTALLATION & OPERATION MANUAL

image

Contents

1. Serial Number Mfg Date How did you first hear about our product Please check one Friend Family __ Burn Trailer Demonstration ___ Internet Other Where did you receive information about our product Please check one Recd info via phone Dealer Name of dealer nternet Other IMPORTANT NOTICE THIS REGISTRATION INFORMATION MUST BE ON FILE FOR THIS WARRANTY TO BE VALID PLEASE MAIL THIS INFORMATION WITHIN THIRTY 30 DAYS FROM THE DATE OF PURCHASE Mail To England s Stove Works Inc Technical Support Department P O Box 206 Monroe VA 24574 Or Fax To 434 929 4810 24 hours a day Or now available Go online to complete your Warranty Registration Visit www heatredefined com if you prefer to register online 35 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS GUIDE D INSTALLATION ET D UTILISATION NUM ROS DE MOD LE 10 CPM 49 TRCPM 49 SHCPM Merci d avoir achet ce produit issu d une excellente gamme d appareils de chauffage Nous vous souhaitons de profiter d un chauffage agr able et s curitaire pendant de nombreuses ann es gr ce votre nouvel appareil de ch
2. 18 19 20 21 22 Keep corn pellets and all other combustible materials a safe distance from the unit This unit will require floor protection if installed on a combustible surface The minimum floor protector for this unit is 36 x 48 which should give you at least six inches 6 of protection at the rear and at each side and six inches 6 minimum in the front of the unit Horizontal runs should not exceed four feet 4 with a maximum vertical flue height of thirty five feet 35 At fifteen feet 15 the pipe should be increased to four inch 4 corn vent pipe This unit should be turned off and allowed to cool prior to cleaning Any ashes should be kept in an airtight metal container and not disposed of until they are completely cooled Read the instructions thoroughly including instructions concerning the digital control board and save them for future reference Do not allow paint chemicals or construction dust on or near your unit Do not allow liquid or ANY foreign materials on or inside your unit Shut your unit down and cover it when painting construction or similar activity is taking place Wipe and clean your unit after any construction is done in your home or if any foreign material gets on or inside your unit You may also need to remove the rear and side cover plates to your unit unplug unit first and vacuum and clean the motors and inside of your unit Improper gasket maintenance including fai
3. R glage de l agitateur la page 14 3 Suivez les instructions relatives l allumage 17 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE E Codes Les E Codes ou codes d erreur sont des codes qui apparaissent sur les crans d affichage associ s la plage de chaleur et la vitesse du ventilateur dans le panneau de commande lorsque votre appareil ne fonctionne pas normalement Si l un de ces codes apparait laissez l appareil refroidir compl tement avant de tenter de remettre l appareil en marche Si l appareil affiche toujours un ou plusieurs E Codes veuillez communiquer avec le Service de soutien technique au 1 800 245 6489 avant de tenter de remettre votre appareil en marche nouveau REMARQUE E 0 signifie Pas d erreur E 2 Echec du d marrage E 3 L appareil a surchauff Si le code E 3 appara t sur votre panneau de commande votre appareil a surchauff Vous devez laisser l appareil refroidir et nettoyer
4. e Rangez vos granules dans un endroit sec pour viter qu elles absorbent un exc dent d humidit e Pour r duire l accumulation de sciure de bois vous devez passer l aspirateur dans la tr mie apr s avoir utilis 6 8 sacs de granules ou plus souvent si les granules sont de moindre qualit Il est possible que vous ayez tamiser chaque sac de granules si la sciure de bois devient un probl me e La taille et la teneur en cendres des granules de bois peuvent galement varier de moins de 1 jusqu 3 96 ou plus Votre appareil chauffera plus efficacement si vous utilisez des granules de petite taille ou de taille moyenne Les granules faible teneur en cendres vous permettront de chauffer le po le plus longtemps entre les nettoyages e Votre appareil est con u pour la combustion de granules d une largeur maximale de 6 35 mm de diam tre et de 6 35 cm de longueur ATTENTION NE PLACEZ PAS CES COMBUSTIBLES DANS L ESPACE DE D GAGEMENT ENTOURANT L APPAREIL DE CHAUFFAGE OU DANS L ESPACE NECESSAIRE AU NETTOYAGE ET AU RETRAIT DES CENDRES MA S GREN S ch pr f rablement avec un taux d humidit de 11 12 96 Ne br lez jamais de mais pour cerfs car il contient souvent de la m lasse ou du sucre Rangez votre approvisionnement de mais dans un endroit sec et gardez le contenant ou les sacs scell s pour viter que votre mais absorbe un exc dent d humidit V rifiez r guli rement le taux d humidit pour vou
5. po sur le c t gauche du moteur d entrainement Desserrez ce boulon Retirez les deux 2 boulons de montage C de po Faites glisser le support du moteur d entrainement vers l avant du po le et retirez la chaine de la roue dent e B Retirez la charni re et le moteur par le panneau d acc s et d branchez les deux fils de tension du moteur BE ND No o0 Retirer le moteur et la roue dent e Retirez le boulon de r glage de la cha ne A de we po Localisez la vis de calage t te hexagonale de po sur la roue dent e et desserrez la Retirez la roue dent e B de la tige du moteur Retirez les quatre 4 vis de montage du moteur d entra nement D l aide d un tournevis douille ou d une douille de 6 po BR ND REMARQUE Lorsque vous r installez la roue dent e alignez la vis de calage t te hexagonale de 4 po sur le c t plat de la tige du moteur Remplacer la tige d entra nement de l agitateur Retirez le bouchon moul du c t droit en regardant de l avant du po le l aide d une cl hexagonale de 6 po Localisez le panneau d acc s situ sur le c t droit en regardant de l avant du po le Retirez les quatre 4 vis de montage D de 5 6 po Localisez le support du moteur d entra nement retenu par deux 2 boulons C de po Desserrez ces boulons Localisez le boulon de r glage de la cha ne A de po sur le c t gauche du moteur d entr
6. INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Suie et cendres volantes Formation et importance du retrait Les produits de combustion contiendront de petites particules de cendres volantes Ces cendres volantes s accumulent dans le syst me d vacuation par ventilation et restreignent le flux des gaz de combustion La combustion incompl te comme celle qui survient lors du d marrage et de l arr t du po le ou en cas de mauvais fonctionnement du po le produira de la suie qui s accumulera dans le syst me d vacuation par ventilation Inspectez le syst me d vacuation par ventilation au moins une fois par ann e pour savoir s il a besoin d tre nettoy ENTRETIEN ATTENTION DEBRANCHEZ L APPAREIL AVANT N IMPORTE QUEL ENTRETIEN CONSULTEZ LA VUE ECLATEE ILLUSTRATION 8 POUR DES REFERENCES SUR LES PIECES Remarque Pour effectuer des r parations sur cet appareil le panneau arri re en m tal doit tre retir du po le pour en permettre l acc s Une 1 vis maintient ce panneau l arri re du po
7. 30 CPM LCP Left Side Cover plate 31 CA ATUF Auger Tube Assembly 32 PU ATGUF Auger Tube Gasket 33 CU 047042 2 RPM Auger Motor 34 PU 4C447 Convection Air Blower 35 PU HFGUF Hopper Flange Gasket 36 CPM RAP Rear Access Panel 37 CPM HOP Hopper 38 AC GGK Hopper Lid Gasket 39 CPM HL Hopper Lid 40 PU 62 40 151 3 Hopper Lid Latch 41 CA AMPP Auger Mounting Plate 42 CA AC Auger Coupler 43 AC HLS Hopper lid Switch 44 PU CH6 Igniter 45 PU HLG Hopper Top Gasket 46 CPM PGB52 Insulation Exhaust Tube Gasket 47 AC SHN Brushed Nickel Spring Handle not shown 48 AC SH Brass Spring Handle not shown 49 AC DGKCPM Door Gasket not shown 50 PU GP Guide Plate not shown 51 CU RG Rubber Gasket not shown 52 CPM APG Ash Pan Gasket not shown 53 CPM AP Air Pump not shown 28 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS See Item numbers on Exploded Diagram for part location 10 CPM Exploded Diagram for Part Location Pellet Corn Multi fuel Stove Exploded View Diagram Illustration 8 Dimensions of your corn pellet multi fuel unit 27 5 W x 30 gH x 31 4 D 391 Ibs Approx 18 height from floor to center of exhaust CAUTION UNPLUG THE U
8. ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Ajustements des loquets du couvercle de la tr mie Les joints d tanch it autour de la partie sup rieure de la tr mie granules sont essentiels pour le fonctionnement s r et efficace de l appareil Le loquet install sur cet appareil sert tenir le couvercle de la tr mie serr sur ce joint Au fil des utilisations ces joints s usent et se compressent La tension du loquet doit donc tre v rifi e p riodiquement et ajust e au besoin Pour r gler le loquet du couvercle vous avez besoin des outils suivants deux cl s de 1 2 po ou une cl de po et une douille de 1 2 po Pour ajuster le loquet ouvrez d abord le couvercle de la tr mie puis verrouillez le loquet dans sa position ferm e Ensuite l aide de la cl de 2 po desserrez l crou le plus proche du loquet Cet crou est alors ajust pr s du couvercle lui m me pour serrer le loquet Apr s avoir ajust cet crou la position d sir e maintenez le en place avec la cl de 1 2 po puis serrez l crou de retenue sur le bout de l axe du loquet avec la douille de 2 po ou la seconde cl de facon maintenir en place l ensemble loquet Enfin
9. TO AVOID ELECTRICAL SHOCK ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE ATTEMPTING ANY REPAIR IF THIS GUIDE DOES NOT CORRECT THE PROBLEM CALL YOUR LOCAL DEALER OR OUR TECHNICAL SUPPORT AT 1 800 245 6489 Unit shuts down in 20 to 30 minutes E 2 error code 11 Unit keeps shutting down E codes on control board 12 Fire goes out and stove shuts down Fuel may stop feeding Loose heat sensor Control board settings Failure to start Blocked flue E 2 Unit Overfired E 3 Improper installation E 2 Stirrer gummed up burnpot plugged Hopper empty Auger turning but fuel not feeding Auger jams Auger has come loose Hopper lid switch tripped Temperature sensor Hi limit Vacuum switch tripped Caused by exhaust blower not running or venting blocked Auger motor not operating Check stove connection Check settings always start unit on 5 to 9 setting Check igniter for buildup Check for flue blockage nests rodents excess soot etc If you see the E 3 code displayed on your control board you have overfired your unit You must let the unit cool and clean the Firebox and burnpot Be sure to clean the orifices holes in the burnpot You should not burn your unit on High Heat Range 9 continuously when burning corn After a couple of hours burning corn on high set the heat range to 7 and the blower to 9 Running the unit on high when burning corn for long perio
10. amount and type of insulation type of air movement and heat distribution and the location of the product e Important Your home must be checked to verify that there is no negative pressure that will affect the operation of this appliance e IMPORTANT DO NOT BURN TREATED SEED CORN IN YOUR STOVE Seed corn is treated with chemical pesticides that are harmful or fatal if swallowed therefore seed corn is dangerous to have in the house especially where children can reach it Burning treated seed corn in your stove will void your warranty and will destroy the exhaust System on the unit e There are many varieties of corn grown around the world Each variety has unique characteristics including the shape and size of the kernel Your stove will burn more consistently with a small to medium kernel corn If the kernel size of the corn varies greatly or if you switch sources frequently you will get a less consistent burn Do not use corn with high wax content e Vacuum the hopper out after every 6 8 bags to eliminate buildup of saw dust and fines from corn e Your unit was primarily designed to burn pellets but will also burn dried cherry pits Make sure your supplier is selling Dried Cherry Pits preferably with less than 496 moisture content for use as fuel in pellet burning stoves IMPORTANT DO NOT USE CHERRY PITS DESIGNED FOR CRAFTS AND HOBBIES This type is usually bleached and or over dried 6 IMPORTANT READ AND FOLLOW ALL
11. le Pour retirer le panneau vous devez retirer les couvercles des tuyaux d vacuation et d admission 6 vis Moteur de la vis granules Le moteur de la vis granules et la boite engrenages forment un ensemble num ro de pi ce CU 047042 qui peut tre retir en d branchant les fils de tension et en d vissant les deux vis de calage hexagonales de po sur le devant de l ensemble Une fois les vis de calage desserr es l ensemble complet glissera du tube de la vis granules REMARQUE La tr mie doit tre vid e et les granules retir es de la vis granules avant de retirer l ensemble Ventilateur de convection Le ventilateur de convection air ambiant num ro de pi ce PU 4C447 peut tre retir en d branchant les fils de tension et en d vissant les quatre vis de montage Ensuite le ventilateur glissera hors du po le Effectuez ces tapes dans l ordre inverse pour installer un nouveau ventilateur Ventilateur de combustion Pour nettoyer ou remplacer le ventilateur de combustion d vacuation num ro de pi ce PU 076002B les fils de tension du ventilateur et le tuyau de ventilation pour po le mais doivent tre d branch s Ensuite retirez les vis qui maintiennent en place le ventilateur au tube d vacuation en acier et faites glisser le ventilateur hors du po le La roue le tube et le tube d vacuation en acier du ventilateur de l appareil devraient tre bross s et nettoy s l aide d un aspirateur
12. ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Mod le 10 CPM 49 TRCPM 49 SHCPM Date de fabrication 1 N de s rie Po le granules de bois pouvant tre utilis dans les maisons mobiles WHI aw is Test selon les normes UL 1482 ASTM E 1509 ULC S627 WIN 14374 CARACT RISTIQUES LECTRIQUES 120 V 60 HZ 5 5 A PR VENTION DES RISQUES D INCENDIE e Installez et utilisez cet appareil uniquement conform ment au guide d utilisation qui l accompagne e Contactez les autorit s locales en mati re de construction ou le service d incendie pour en savoir plus propos des restrictions et des inspections d installations dans votre r gion Con u pour tre utilis avec des granules de bois du mais ou des noyaux de cerise uniquement Les granules de bois doivent avoir un diam tre de 6 3 mm Ne raccordez pas ce po le un conduit de fum e d j utilis pour un autre appareil La porte principale du po le et la porte de retrait de la cendre doivent rester bien ferm es pendant que l appareil fonctionne D bit calorifique granules 2 04 kg h D bit calorifique mais 2 13 kg h D bit calorifique noyaux de cerise 1 58 kg h Cet appareil DOIT tre install
13. Ajoutez un nouveau joint num ro de pi ce PU CBG entre le rebord du ventilateur et le tube d vacuation en acier lorsque vous nettoyez ou remplacez le ventilateur Interrupteur de l aspirateur Cet appareil poss de un interrupteur d arr t de l aspirateur num ro de pi ce CU VS qui permet d aider contr ler certaines fonctions de l appareil Si une erreur de fonctionnement survient dans l appareil un interrupteur arr tera d alimenter la vis granules Parmi les situations qui pourraient provoquer cela on retrouve une panne de courant une panne du ventilateur de combustion une installation incorrecte du conduit de fum e un conduit de fum e bloqu en raison de rongeurs de nids etc ou une combustion sale la suite de la combustion d un mauvais combustible consultez la section Informations importantes au d but du manuel Allumeur Cet appareil poss de un allumeur automatique num ro de pi ce CPM CH qui se met en marche en appuyant sur le bouton ON sur le panneau de commande Si vous utilisez des granules ou du mais s ch s vous ne devriez pas avoir de probl me avec l allumeur Si vous croyez que l allumeur est d fectueux consultez la section Allumer votre appareil manuellement la page 15 et communiquez avec le Service de soutien technique Remarque Du mais dont le taux d humidit est sup rieur 12 peut faire en sorte que l appareil ne s allume pas automatiquement Vous devrez allumer v
14. DE PORT E DES ENFANTS LE CONTACT AVEC L APPAREIL PEUT BR LER LA PEAU CONSULTEZ LA PLAQUE SIGNAL TIQUE ET LES INSTRUCTIONS Fabriqu par England s Stove Works P O Box 206 Monroe VA 24574 Vous pouvez inscrire la date de fabrication et le num ro de s rie de votre appareil dans les espaces pr vus cet effet sur cette tiquette pour r f rence ult rieure Cette tiquette comprend galement des renseignements de s curit tels que la norme d essai UL et autres l intention de vos repr sentants locaux ou de toute autre personne qui peut en avoir besoin 34 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Ayez ces renseignements port e de la main si vous appelez le fabricant ou votre d taillant au sujet de ce produit conserver dans vos dossiers Num ro de mod le Date d achat Date de fabrication Num ro de s rie GARANTIE LIMIT E DE CINQ 5 ANS A PARTIR DE LA DATE D ACHAT PAR LE PROPRIETAIRE D ORIG
15. INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS VENT TERMINATION CLEARANCES A MIN 4 FT CLEARANCE BELOW OR BESIDE ANY DOOR OR WINDOW THAT OPENS B MIN 1 FT CLEARANCE ABOVE ANY DOOR OR WINDOW THAT OPENS C MIN 2 FT CLEARANCE FROM ANY ADJACENT BUILDING D MIN 7 FT CLEARANCE FROM ANY GRADE WHEN ADJACENT TO PUBLIC WALKWAYS E MIN 2 FT CLEARANCE ABOVE ANY GRASS PLANTS OR OTHER COMBUSTIBLE MATERIALS F MIN 3 FT CLEARANCE FROM A FORCED AIR INTAKE OF ANY APPLIANCE G MIN 2 FT CLEARANCE BELOW EAVES OR OVERHANG H MIN 1 FT CLEARANCE HORIZONTALLY FROM COMBUSTIBLE WALL I VENTS INSTALLED WITH MECHANICAL EXHAUSTERS SHALL TERMINATE NOT LESS THAN 12 IN 305MM ABOVE THE HIGHEST POINT WHERE THEY PASS THROUGH THE ROOF SURFACE Notes on termination of Pellet Vent Pipe from NFPA 211 2006 ed Section 10 4 Termination 10 4 5 Sen also INSTALLATION section of manual AND additional notes above Not less than three 3 feet above any forced air inlet located within ten 10 feet Not less than four 4 feet below four 4 feet horizontally from or one 1 foot above any door window or gravity air inlet into any building Not less than two 2 feet from an ad
16. SOUTIEN TECHNIQUE AU 1 800 245 6489 Le feu s teint et le po le s arr te L alimentation par le combustible est peut tre interrompue L agitateur s est encrass le pot de combustion est bouch La tr mie est vide La vis granules tourne mais le combustible n alimente pas le feu La vis granules se bloque La vis granules s est desserr e L interrupteur du couvercle de la tr mie s est d clench Le capteur de limite de haute temp rature s est d clench L interrupteur de l aspirateur s est d clench Caus par un ventilateur d vacuation non fonctionnel ou une a ration bloqu e Le moteur de la vis granules ne fonctionne pas Retirez et nettoyez l agitateur jetez les cendres du bac cendres et nettoyez le pot de combustion Remplissez la Un m lange inad quat d air peut faire en sorte que l appareil br le le combustible plus rapidement que se fait l alimentation par la vis granules Retirez la vis granules et nettoyez la Les blocages de la vis granules peuvent tre un probl me caus par l utilisation de combustible de basse qualit ou s il y a une accumulation de particules sciure de bois pis de mais enveloppes etc dans la tr mie Les blocages de la vis granules sont signal s lorsque celle ci tourne mais qu aucun combustible n alimente le feu V rifiez si le moteur de la vis granules tourne alors que celle ci ne tourne pas REMARQUE La vi
17. Technical Support at 800 245 6489 if you have questions regarding the fuel you are trying to burn This stove was tested with 1 Hardwood Pellets 2 Shelled Corn 3 Cherry Pits 5 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS e The Pellet Corn Multi fuel stove is tested for operation with corn with 14 or less moisture content it is recommended that corn with 11 1296 moisture be used for most efficient operation of this unit Corn with over 1296 moisture has a lower BTU value and will be hard to burn on the lower settings e Corn must be clean and free from debris never burn corn straight from the field Stalk parts excessive fines and cob remnants etc will clog the auger mechanism We highly recommend the use of a sifter sifters to filter your corn are available from dealers Damage caused by dirty and or unfiltered unsifted corn is not covered by the product warranty ask for and use clean filtered bagged corn only e DISCLAIMER NOTICE No guarantee is made regarding the heating capacity of this product The actual area that this unit will heat depends on factors such as building conditions heat loss type of construction
18. The Auger Motor and gearbox are one complete assembly Part CU 047042 and can be removed by disconnecting the power leads and loosening the two Allen set screws in front of the assembly Once the set screws are loosened the entire assembly will slide from the auger tube NOTE The hopper must be emptied and pellets removed from the auger before removing the assembly Convection Blower The Convection room air Blower Part PU 4C447 can be removed by disconnecting the power leads and removing the four mounting screws Once this is done the blower will slide out of the stove This procedure can be reversed to install a new blower Combustion Blower To clean or replace the Combustion exhaust Blower Part PU 076002B the power leads from the blower and the corn vent pipe must be disconnected Next remove the screws that hold the blower to the steel exhaust tube and slide the blower from the stove The blower impeller blower tube and steel blower exhaust tube on the unit should be brushed and vacuumed When cleaning or replacing the blower a new gasket Part PU CBG should be added between the blower flange and the steel exhaust tube Vacuum Switch This unit is equipped with a Vacuum Shutdown Switch Part CU VS which helps control various functions of the unit If an operational error occurs in the unit a switch will stop the feed auger Situations which could cause this include power failure Combustion Blower failure impro
19. Vous devez couvrir l aide d un grillage l extr mit ext rieure du tuyau pour emp cher tout corps tranger d entrer dans le syst me Pour ce faire vous pouvez utiliser notre ensemble de raccord l air ext rieur num ro de pi ce PU OAK Si l appareil est situ sous le niveau du sol vous devez installer la partie verticale du tuyau l int rieur avant de faire passer celui ci travers le mur vers l ext rieur de l habitation REMARQUE Si la longueur totale du raccordement d passe 1 82 m s il pr sente plus de deux coudes ou s il s agit d une installation en sous sol utilisez plut t un tuyau et un raccord m tallique de 3 po Installation dans une maison mobile Fixez l appareil de chauffage au sol l aide des deux trous du socle Si l appareil est install sur une surface combustible vous devez percer des trous correspondants ceux du socle dans le protecteur de plancher de votre choix consultez la section Protection du plancher Pr servez l int grit structurelle de la maison et assurez vous que l appareil est mis la terre de facon permanente la charpente de votre maison N oubliez pas que l utilisation de l air de combustion ext rieur est obligatoire et qu il ne faut pas installer l appareil dans une chambre coucher Consignes importantes concernant l installation INSTALLATION INAD QUATE Le fabricant ne sera pas tenu responsable des dommages caus s par le mauvais fonctionnement d un po le
20. aluminium England s Stove Works recommande l utilisation d un tuyau verrouillage par rotation de Dura Vent si vous utilisez un autre tuyau consultez les codes du b timent locaux ou un inspecteur en b timent et fixez chaque joint l aide d au moins trois vis consultez la section Informations importantes N utilisez pas de tuyau de type B ou de tuyau galvanis avec cet appareil Le tuyau pour po le mais est concu pour tre d mont afin d tre nettoy et doit tre v rifi plusieurs reprises pendant la saison de chauffage le tuyau de ventilation pour po le mais n est pas fourni avec l appareil et doit tre achet s par ment N installez pas de registre de tirage dans ce syst me et ne raccordez pas cet appareil un syst me de conduit de fum e d j utilis pour un autre appareil de chauffage travers le mur Pour installer le tuyau de ventilation de l appareil travers le mur raccordez l adaptateur de tuyau l adaptateur du moteur d vacuation Si l adaptateur d vacuation est une hauteur minimale de 45 72 cm au dessus du niveau du sol vous pouvez utiliser une section droite de tuyau pour po le mais pour traverser le mur voir illustration 1 Votre d taillant ou notre usine doivent tre en mesure de vous fournir un ensemble permettant d effectuer la majeure partie de cette installation qui inclura une bague murale permettant de maintenir un d gagement ad quat travers un mur com
21. approved Corn Vent pipe and fasten each joint of the pipe with at least three screws 9 Outside combustion air is mandatory for these units to work properly Make this connection using a 1 g I D metal pipe steel aluminum or copper and coupler Be sure to secure the pipe to the unit with a clamp or aluminum tape The outside end should be covered screened to prevent any foreign matter from entering the system Try to keep the number of bends in this pipe to a minimum Our Part Number PU OAK Outside Air Kit with flex pipe can be used NOTE f the total run of the connection exceeds six feet 6 use 3 metal pipe and coupler instead 10 Regularly inspect the burnpot area remove the feeder pot and clean all plugged holes See Maintenance Section 11 The ash in the burnpot should be removed regularly depending on your burn rate The area to the right and left of the burnpot is for ash storage keep the air holes in the burnpot clean for a more efficient burn Check your exhaust system frequently Refer to Ash Removal and Disposal section 3 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS 12 13 14 15 16 17
22. dente Assurez vous que l agitateur tourne avant de vous loigner de l appareil 4 minutes apres le d marrage l agitateur commencera tourner Puisqu il tourne tr s lentement prenez le temps de l observer pour vous assurer qu il bouge r ellement REMARQUE Lors du premier feu la premi re fois que vous utilisez l appareil pour la combustion le panneau de commande devrait tre r gl la puissance 5 pour la plage de chaleur et la puissance 5 pour la vitesse du ventilateur pendant au moins 3 heures afin de permettre l appareil de se purifier en br lant les huiles utilis es lors de la fabrication Vous devez ouvrir les fen tres et les portes de la maison pour mieux l a rer pendant la combustion de ces huiles REMARQUE Si l appareil ne d marre pas ne tentez PAS de le faire red marrer avant qu il ne soit compl tement refroidi Si l appareil ne d marre pas ou si le feu s teint le code E 2 s affichera sur les crans associ s la plage de chaleur et la vitesse du ventilateur sur le panneau de commande Dans un tel cas laissez l appareil refroidir compl tement et r p tez les tapes ci dessus REMARQUE Le pot de combustion et l agitateur font partie d un syst me mobile Cela signifie que vous verrez le syst me monter et descendre L appareil est congu pour la combustion de plusieurs mati res cette fonctionnalit permet l appareil de fonctionner sans ralentir ou se bloquer en raison
23. des fuites d air causant des retours de fum e Gardez l esprit que comme pour tout appareil de chauffage il incombe l utilisateur de veiller ce que l installation le fonctionnement et l entretien du produit soient ad quats Veuillez consulter les codes locaux et communiquer avec le service de soutien technique au 1 800 245 6489 si vous avez des questions Assurez vous de suivre les instructions des fabricants de tous les produits tiers que vous utilisez comme le tuyau d vacuation Ne d posez jamais d allume feu y compris les produits g lifi s sur une surface chaude ou sur des charbons chauds Installation en sous sol L installation en sous sol doit uniquement tre effectu e par un installateur professionnel Pour les installations en sous sol vous devez utiliser un tuyau et un raccord de 3 po pour l admission d air de combustion ext rieur A l ext rieur de l habitation vous devez respecter un d gagement minimal de 0 91 m entre le sol et la sortie du tuyau de ventilation pour po le mais Gardez l esprit que chaque coude r duit jusqu 30 96 du tirage il est conseill d ajouter 0 91 m de hauteur de tuyau pour chaque coude que l installation comporte Exemple Apr s le deuxi me coude ajoutez 1 82 m de hauteur avant de terminer le tuyau de ventilation DANGER N ouvrez pas la porte de l appareil si l agitateur fonctionne toujours Consultez les instructions de R glage de l agitateur fournies plus loin d
24. et le solin de toit appropri s fournis par le fabricant du tuyau suivez les instructions du fabricant du tuyau et consultez l illustration 1 du pr sent guide Il est important de noter que si la hauteur de vos tuyaux mesure plus de 4 57 m vous devez passer un tuyau de ventilation pour po le mais de 4 po de diam tre Ne d passez pas une longueur horizontale de tuyau de 1 21 m et tentez d installer le moins de coudes possible dans le syst me de conduit de fum e Si un d voiement est n cessaire il est pr f rable d installer un coude 45 degr s si possible N oubliez pas que l installation de coudes peut r duire jusqu 30 du tirage par coude Air ext rieur prise d air de combustion ext rieur L air utilis par cet appareil doit provenir de l ext rieur afin d assurer son bon fonctionnement Cet appareil a t congu et test avec ce raccordement parce que de nombreuses maisons sont tanches l air et que l air de combustion l int rieur de l habitation n est pas ad quat Le tuyau d admission est situ sur le c t inf rieur du pot de combustion l arri re et poss de un diam tre int rieur de 1 1 2 po Vous pouvez effectuer le raccordement qui traverse le mur l aide d un raccord et d un tuyau m talliques de 1 s po de diam tre int rieur consultez la section Informations importantes du pr sent guide Assurez vous de fixer le tuyau l appareil l aide d un collier ou de ruban en aluminium
25. le foyer et le pot de combustion Assurez vous de nettoyer les orifices trous dans le pot de combustion Vous ne devriez pas faire fonctionner votre appareil une temp rature lev e continuellement plage de chaleur 9 lorsque vous utilisez du mais comme combustible Apr s avoir fait br ler du mais pendant quelques heures une temp rature lev e baissez la plage de chaleur 7 et augmentez la vitesse du ventilateur a9 AVERTISSEMENT Faire fonctionner l appareil une temp rature lev e lorsque vous utilisez du mais comme combustible sur une p riode prolong e peut endommager l appareil REMARQUES PROPOS DE L UTILISATION Premier feu Lorsque vous appuyez sur le bouton ON le panneau de commande sera automatiquement r gl la puissance 5 pour la plage de chaleur de m me que pour la vitesse du ventilateur Laissez le po le chauffer ainsi pour au moins trois 3 heures De cette facon la chaleur de l appareil br lera la peinture et les huiles provenant du processus de fabrication Nous vous recommandons d ouvrir les portes et les fen tres de votre r sidence au cours de cette op ration D marrages froid subs quents Dans les situations de d marrage froid l appareil devrait fonctionner la puissance 5 jusqu ce que le ventilateur d air ambiant se mette en marche REMARQUES IMPORTANTES Soyez patient Votre appareil poss de un grand pot de combustion et il lui faut
26. mit doit vacuer la fum e une hauteur plus lev e que la prise d air L installation DOIT comporter un tuyau de ventilation pour po le mais d une hauteur minimale de 3 pi Le tirage naturel qui en r sultera permettra d viter que de la fum e ou des odeurs ne se d gagent durant l arr t de l appareil et d viter que le syst me d vacuation ne repr sente une nuisance ou un danger pour les gens ou les arbustes qui pourraient tre expos s des temp ratures lev es NE RACCORDEZ PAS CE POELE A UN CONDUIT DE FUMEE DEJA UTILISE POUR UN AUTRE APPAREIL NE PAS RACCORDER DIRECTEMENT A UNE CHEMINEE EN MACONNERIE e Distances partie des portes des fen tres de la prise d air par gravit ou de la prise d air de ventilation d un b timent au moins 1 21 m en dessous 1 21 m lat ralement et 0 3 m au dessus cela ne s applique pas pour les fen tres non ouvrantes ou celles qui ont t fix es de mani re ce qu elles ne s ouvrent pas e Distance minimale entre le bas de l extr mit et le niveau du sol 0 91 m Cette distance d pend des plantes et de la nature de la surface du sol Les gaz de combustion sont assez chauds pour enflammer l herbe les plantes les arbustes etc situ s proximit de l extr mit Le sol ne doit pas tre une pelouse La distance minimale entre le bas de l extr mit et les voies publiques est de 2 13 m 8 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENT
27. optimal Une trop grande accumulation de cendres g ne la circulation d air r duit l efficacit de l appareil et peut produire un retour de fum e Suivez les conseils de nettoyage du DVD Entretien quotidien pour la cendre Appuyez sur la commande tactile OFF et laissez le po le s arr ter environ cinq 5 minutes avant d ouvrir la porte Un tournevis ou un couteau mastiquer manche long peuvent tre utilis s pour enlever toute accumulation ou cro te pr s du pot de combustion Retirez et nettoyez le pot de combustion voir la page 15 Si vous br lez des granules de bois il est possible qu un nettoyage quotidien ne soit pas n cessaire Bac cendres REMARQUE Le bac cendres doit tre fix fermement lorsque l appareil fonctionne Ne faites JAMAIS fonctionner l appareil lorsque le bac cendres est retir ou mal fix Cet appareil poss de un bac cendres pour un nettoyage plus pratique et sans tracas Pour le retirer soulevez le par la poign e puis tirez le bac cendres vers l avant REMARQUE Il y a deux poign es au dessus du bac cendres Celles ci contr lent deux panneaux d acc s un de chaque c t l int rieur de l appareil au bas pour mettre les cendres dans le bac cendres Tirez les poign es vers vous pour ouvrir les panneaux poussez les cendres dans le bac cendres puis replacez les panneaux en vous assurant que la surface sous chaque plateau est propre avant de le refermer L apparei
28. or if a basement installation use 3 metal pipe and coupler instead Mobile Home Installation Secure the heater to the floor using the two holes in the pedestal If the unit is on a combustible surface you will need to drill matching holes in the floor protection that you choose see Floor Protection section Do not disturb the structural integrity of the home and be sure the unit is permanently electrically grounded to the chassis of your home Remember that outside combustion air is mandatory and not to install the unit in a sleeping room of the home Important Notes Concerning Installation IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 245 6489 and or consult a professional installer if you have any questions IMPORTANT Improper hook up too much pipe too many elbows etc will cause the unit not to operate Call Technical Support 800 245 6489 if you have questions about your hook up or if your unit will not operate IMPORTANT SAFETY NOTE f the unit or chimney connector pipe glows red or white the stove is over fired This condition could cause a house or chimney fire Do not operate your unit too hot or over firing may result 12 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS N
29. poursuivra 26 Le fonctionnement se poursuivra jusqu ce que l appareil Soit mis hors tension sur le panneau de commande ou que la temp rature de fonctionnement descende sous les 32 2 C ce moment l appareil se mettra en Arr t automatique par d faut IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE ACCESSOIRES Les accessoires suivants peuvent tre ajout s votre appareil n importe quel moment apr s l achat Cependant laissez l appareil se refroidir avant d ajouter n importe quel accessoire Thermostat Un thermostat externe tel que nos num ros de pi ces PU DTSTAT mural ou AC 3003 avec commande distance peut tre utilis sur nos appareils granules mais ou multicombustibles tant qu il est basse tension et qu il fonctionne avec le syst me millivolt Apr s avoir d branch l appareil localisez le fil de liaison J 18 sur le bas du panneau de commande Les deux vis devraient ainsi tre desserr
30. recommandons fortement l utilisation d un tamis que vous pouvez vous procurer chez un d taillant Les dommages caus s par du mais non nettoy ou non tamis non cribl ne sont pas couverts par la garantie du produit demandez et utilisez uniquement des sacs de mais nettoy et tamis AVIS DE NON RESPONSABILIT Nous n offrons aucune garantie quant la capacit de chauffage de ce produit La zone r elle chauff e par cet appareil d pend de facteurs tels que la condition du b timent la perte de chaleur le type de b timent la quantit et le type d isolant le type de circulation d air et de distribution de la chaleur et l emplacement du produit Important Vous devez faire inspecter votre maison pour v rifier qu aucune pression n gative ne peut nuire au fonctionnement de cet appareil IMPORTANT NE FAITES PAS BR LER DE MA S DE SEMENCE TRAIT DANS VOTRE POELE Le mais de semence est trait avec des pesticides chimiques dont l ingestion peut tre nocive ou fatale Par cons quent il est dangereux d avoir du mais de semence la maison surtout dans un endroit accessible aux enfants La combustion de mais de semence trait entra nerait l annulation de la garantie et d truirait le syst me d vacuation de l appareil ll existe plusieurs vari t s de mais cultiv es partout dans le monde Chaque vari t poss de des caract ristiques uniques comme la forme et la taille des grains Votre po le chauffera de mani
31. setting 5 Allow the stove to burn in this manner for at least three 3 hours This will allow the unit to cure out as the paint and the oils from the manufacturing process burn off We recommend you open doors and windows in your dwelling during this process Subsequent Cold Starts In a cold start situation the unit should be operated at a 5 setting until the room air blower begins to operate IMPORTANT NOTES Please be patient Your unit has a large burnpot and it takes awhile to equalize reach maximum heat levels Do not be concerned by the size of the flame as this unit gets much hotter than the flame appears Use gloves when filling the hopper If you leave the hopper open too long the stove will shut down NOTE Press the ON button only once on start up Except when the hopper is empty when you run out of fuel or for your first fire see above press and hold the ON button for 10 seconds to purge the unit Pressing the ON button a second time during the start up cycle will cause the start up cycle to begin again IMPORTANT f the unit fails to start properly or does not properly complete the Shut Down procedure open the closest outside door and a window to eliminate the home s natural draft BEFORE opening the stove s door or hopper lid This will allow any smoke to exit through the external air hook up instead of spilling into the home 18 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTEN
32. tement 9 V rifiez que le ventilateur d vacuation fonctionne et ventile le po le correctement Si ce n est pas le cas v rifiez les branchements et nettoyez ou remplacez le 10 Permettez au combustible de s cher ou m langez le avec quelques granules de bois 11 V rifiez si l int rieur du po le et les tuyaux d vacuation sont obstru s Tapotez les murs int rieurs du foyer nettoyez derriere les plaques d acc s les plus basses situ es dans le mur int rieur arri re c t du pot de combustion nettoyez les orifices d a ration du pot de combustion et du foyer au dessus de la plaque de briques r fractaires 12 R duisez le r glage de chaleur 13 De l air comburant ext rieur est obligatoire Notre num ro de pi ce PU OAK est acceptable Une installation inad quate peut cr er un refoulement d air REMARQUE V rifiez galement si le boyau de l aspirateur est l che ou fissur sur les interrupteurs du ventilateur voir le sch ma des pi ces REMARQUE Une pression n gative dans un logement est un probl me s rieux Cet appareil doit tre install avec l ensemble de raccords l air ext rieur num ro de pi ce PU OAK ATTENTION D BRANCHEZ L APPAREIL AVANT N IMPORTE QUEL ENTRETIEN 31 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR
33. un moment pour s adapter atteindre les niveaux de chaleur maximums Ne vous inqui tez pas de la taille de la flamme cet appareil devient beaucoup plus chaud que la flamme ne le laisse croire Utilisez des gants pour remplir la tr mie Si vous laissez la tr mie ouverte trop longtemps le po le s teindra REMARQUE Appuyez sur le bouton ON une fois pour mettre l appareil en marche Appuyez sur le bouton ON et maintenez le enfoncer pendant 10 secondes pour faire une vidange de l appareil sauf lorsque la tr mie est vide lorsque vous tes court de combustible ou lors de votre premier feu voir ci dessus Si vous appuyez sur le bouton ON une seconde fois au cours du cycle de d marrage celui ci red marrera IMPORTANT Si l appareil n arrive pas d marrer correctement ou si la proc dure d arr t ne s est pas effectu e correctement ouvrez la porte ext rieure la plus proche et une fen tre pour liminer le courant d air naturel de la maison AVANT d ouvrir la porte du po le ou le couvercle de la tr mie Cela permettra la fum e de sortir par le raccordement d air ext rieur au lieu de se r pandre dans la maison 18 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WOR
34. ventilateur et la plage de chaleur jusqu ce que l cran de la vitesse du ventilateur affiche le chiffre 0 Vous pouvez remettre l agitateur en marche en appuyant sur le bouton Air On Temp temp rature de l air entrant situ au bas du panneau de commande puis en appuyant en m me temps sur les deux fl ches orient es vers le haut qui sont associ es la vitesse du ventilateur et la plage de chaleur jusqu ce que l cran de la vitesse du ventilateur affiche le chiffre 1 Cette dent doit pointer vers le haut lorsque vous red marrez le po le aA le c t quatre dents point vers l endroit o se trouve le 12 sur une horloge m Agitateur illustration 2 ATTENTION N utilisez jamais d essence de combustible pour lampe de k ros ne de liquide d allumage pour charbon de carburant diesel ni aucun autre liquide inflammable pour allumer un feu Gardez tout mat riau combustible une distance s curitaire du po le La plage de chaleur et la vitesse du ventilateur seront automatiquement r gl es la puissance 5 r glage par d faut au d marrage pour montrer que le signal de feu est d tect Durant la p riode de d marrage de 20 minutes l utilisateur peut r gler les commandes la chaleur souhait e et apr s cette p riode l appareil fonctionnera selon ce r glage personnalis Lorsque vous br lez du mais la p riode de d marrage est de 30 minutes 14 IMPORTANT LISEZ ET SU
35. votre appareil surchauffe la vis granules arr tera de l alimenter le code d erreur E3 s affichera sur le panneau de commande et l appareil s teindra Si cela se produit vous devez attendre 45 minutes avant de tenter de rallumer l appareil Si vous avez des questions ou des probl mes communiquez avec le Service de soutien technique Technical Support Department service englanderstoves com P O Box 206 Commandes de pi ces SEULEMENT 1 800 516 3636 Monroe VA 24574 Etats Unis Des questions Composez le 1 800 245 6489 T l copieur 1 434 929 4810 Vous pouvez galement commander des pi ces et des accessoires consultez la foire aux questions et encore plus sur notre site Web www heatredefined com 19 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE UTILISATION QUOTIDIENNE Ravitaillement de l appareil Appuyez toujours sur la commande tactile OFF avant d effectuer le ravitaillement La tr mie du po le cont
36. 9 4810 27 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE PI CES DE RECHANGE ARTICLE NUM RO DE PI CE DESCRIPTION DES PI CES 1 CA 10 Porte 2 AC G20 Vitre avec joint 29 21 cm H X 37 46 cm I 3 AC GGK Ensemble pour joint de la vitre 4 AC GSCPM Supports de la vitre 5 CA 11 Moulages des panneaux lat raux 6 CA DH Poign e de porte moul e 7 CPM CFB Panneau de fibres de brique 8 CPM BP Pot de combustion 9 CPM FS Agitateur de combustible 10 CPM MC Bague de l agitateur de combustible de po 11 CA CPMDS Tige d entrainement de l agitateur de combustible 12 R FN HP Goupille d attelage de l agitateur de combustible 13 CPM FST Tube de l agitateur de combustible de 3 po 14 R FN SF 2024 16 Bagues de l agitateur de combustible de 1 po emballages de 2 15 CPM 26CH Chaine d entrainement de l agitateur de combustible 16 CPM SP Roue dent e de l agitateur de combustible emballages de 2 17 CPM SMB Support du moteur de l agitateur 18 PU AF
37. ANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS SHUT DOWN PROCEDURE WARNING NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE POWER SOURCE Refer to the following instructions Press the OFF touch pad to put the stove in the Shut Down mode There will be an S D in the Heat Range and Blower Speed windows while the unit is shutting down to verify this At this time the red light above the OFF pad will illuminate When the OFF pad is touched the auger will instantly stop feeding fuel to the auger tube but the room air blower exhaust blower and Stirrer will continue to operate When the internal temperature drops to 95 degrees the room air blower will cease to operate and when the internal temperature drops to 90 degrees the exhaust blower will stop The red light will then shut off and the entire stove will be shut down The hotter the unit is operating the longer it will take for the stove to complete the Shut Down cycle Note The unit will exit the Shut Down cycle if you press the ON button during Shut Down NOTE If your unit overheats the auger will stop feeding E3 will be displayed on the control board and the unit will go into Shut Down If this happens you need to wai
38. ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS OPERATING INSTRUCTIONS CAUTION DO NOT OPERATE WITH THE DOOR OPEN Do not burn trash paper bags etc in this unit This stove has an induced draft system and is designed to operate continuously as frequent shutdown is not required The setting of the Heat Range touch pad will control the heat output and the amount of fuel the unit will burn see Control Board section NOTE This stove is using solid fuel and will not restart automatically unless a thermostat is installed See page 26 Thermostat instructions NOTE Blower Speed will automatically be adjusted to the desired Heat Range that you select START UP PROCEDURES SETTING THE STIRRER Warning Do not open the door on this unit if the Stirrer is still moving Bodily Injury can occur The stirrer must be set before each burn so that the 4 prong side of the stirrer is pointing straight up see diagram below To rotate the Stirrer press and hold the AIR ON TEMP i e Air On button on the bottom of the Control Panel it will stop rotating when you release the button To turn Stirrer Off and On The Stirrer may be turned Off by pushing the Air On button on the bottom of the Control Panel and then pressing both Down arrows on the Blower Spe
39. AU DETAILLANT COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE au 1 800 245 6489 2 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL A EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PIECES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE 10 11 INFORMATION IMPORTANTE L installation de cet appareil autoportant granules ma s et multicombustible doit uniquement tre effectu e par un installateur professionnel Consultez les codes d installation locaux de votre r gion Appelez votre repr sentant d assurance des propri taires occupants pour faire inspecter l installation de votre po le Lisez et respectez les instructions du pr sent guide Il est n cessaire de tester l appareil Pour cela faites le fonctionner vide pendant 20 minutes avant d y mettre des granules ou des noyaux de cerise Apr s avoir fonctionn vide pendant 20 minutes le po le devrait s teindre automatiquement Le cycle pour la combustion de mais est de 30 minutes Si vous choisissez le chauffage aux granules vous devez utiliser des granules de premie
40. C 33000 Even though this pipe interlocks itis recommended to seal all connections with high temperature silicone our Part Number AC RTV3 or aluminum duct seal tape Use at least three screws to secure the pipe to this unit s exhaust blower Also if you do not use U L approved twist lock corn pipe be sure to use U L approved Corn Vent pipe and fasten each joint of the pipe with at least three screws e The L vent or corn vent stainless exhaust system must be installed so as to be GAS TIGHT Follow the vent manufacturer s installation instructions e The area where the vent pipe penetrates the exterior of the home must be sealed with silicone or other means to maintain the vapor barrier between the exterior and the interior of the home NOTE These are guidelines only Proper venting is accomplished by design and common sense n most installations three inch 3 diameter venting is adequate If it does not vent properly you must change it to four inch 4 diameter venting DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM 9 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS BURNING SOLID FUELS Ashes will need to be rem
41. CE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Panneau de commande Le panneau de commande num ro de pi ce CPM CB07 est un panneau d affichage num rique Ce panneau comprend plusieurs r glages qui permettent de faire fonctionner l appareil Cette pi ce peut tre retir e de l appareil en desserrant les deux vis externes et en poussant le panneau vers l int rieur du po le Le panneau d acc s arri re devrait tre retir avant de retirer le panneau de commande Le panneau de commande utilise un fusible action rapide de 6 amp res Reportez vous l avis de s curit sous le sch ma REMARQUE Les trois boutons de commande inf rieurs sont pr r gl s en usine et ne devraient pas n cessiter de changement Reportez vous aux sections Mode d emploi et Utilisation quotidienne du pr sent manuel pour des instructions sur les autres r glages du panneau de commande Plages de chaleur recommand es Combustion faible R glage de plage de chaleur 1 R glage du ventilateur d air ambiant 1 Moyennement faible R glage de plage de chaleur 2 3 R glage du ventilateur d air ambiant Moyennement lev e R glage de plage de chaleur 4 8 R glage du ventilateur d air ambiant Combustion maximale R glage de plage de chaleur 9 R glage du ventilateur d air ambiant 9 REMARQUE La vitesse du ventilateur
42. COMPONENT OPERATION START OPERATION END Exhaust Blower Starts Immediately Will continue until shutdown Shutdown will Combustion occur when the operating temperature is below 90 degrees Stirrer Three minutes after starting the Stirrer Will continue intermittently as determined by the will begin to turn Heat Setting until Shutdown Auger When starting the auger will begin to The auger will continue at the feed rate turn determined by the Heat Setting NOTE Safety switch Hi Limit and Vacuum Sensor must be activated to continue proper operation Room Fan Begins when 110 degrees is reached Will continue to operate until the unit cools down Convection to below 90 degrees This may take from several minutes up to an hour Automatic If after 15 minutes the unit has not If the timer should expire before the preset Shutdown reached the preset operating temp the operating temperature is achieved resetting the unit will begin to automatically shut timer is possible by switching the Control Board down This will be evidenced by the red OFF and then back ON light on the Control Board Normal Operation If after 15 minutes the preset operating Operation will continue until either the Control temperature of 110 degrees is achieved Board is turned OFF or the operating normal operation will continue temperature falls to below 90 degrees At this time the unit will default to Automat
43. E INSTALL PAR UN INSTALLATEUR QUALIFI TEL QU UN SPECIALISTE CERTIFI PAR LE NFI NATIONAL FIREPLACE INSTITUTE DES ETATS UNIS DIRECTIVES LI ES L INSTALLATION DU SYSTEME D VACUATION PAR VENTILATION INSTALLEZ LE TUYAU DE VENTILATION EN RESPECTANT LES D GAGEMENTS INDIQUES PAR LE FABRICANT DU TUYAU e Vous devez utiliser un tuyau de ventilation pour po le mais de type L homologu UL de 3 ou 4 po pour installer le systeme d vacuation et le fixer au raccord de tuyau situ l arri re de l appareil Utilisez un adaptateur de 3 4 po pour un tuyau de 4 po Vous devez installer un capuchon sur l extr mit des chemin es compos es de tuyaux de ventilation de type L Nous vous recommandons d utiliser un tuyau de type L de 4 po pour les installations une altitude de plus de 762 m e Ne faites pas terminer le tuyau de ventilation dans un endroit ferm ou semi ferm par exemple un abri d auto un garage un grenier un vide sanitaire sous une terrasse ou un porche une all e un espace clos ou tout endroit o la fum e pourrait s accumuler comme une cage d escalier un passage couvert etc e Les surfaces du tuyau de ventilation peuvent devenir suffisamment chaudes pour causer des br lures si vous les touchez Il peut tre n cessaire d utiliser un cran de protection ou un pare feu non combustibles e N installez pas de registre de tirage dans le tuyau d vacuation de cet appareil e l extr
44. EEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Freestanding Pellet Corn Multi fuel Installation Caution Follow the pipe manufacturer s installation instructions and directions for passing through combustible walls and ceilings Check local codes in your area Our Part AC 33000 is acceptable for Must have through the wall minimum 3 installation adapter before tee We recommend 4 for longer run for 2500 ft For shorter run tee installations Our alone is acceptable Part AC 33100 oja E Basement Installation j should be performed by 3 clearance professional installer Use Basement 3 metal pipe and coupler gee for Outside Combustion Air Minimum 3 ft 3 clearance from ground to the Corn Vent Exhaust Pipe Outside AIR IS MANDATORY for this unit to operate properly lL4A iEl If 3 flue pipe exceeds 15 in length increase to 4 flue pipe for remaining flue connections Total flue length should not exceed 35 Horizontal run not to exceed 4 Floor protector required Min size 36 x 48 If the total run of outside air connection exceeds 6 if more than 2 elbows are used or if a basement install use 3 metal pipe and coupler instead Outside Air is mandatory for proper safe operation FLOOR AND WALL PROTECTI
45. ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE TUYAU ASPIR HAUTE TEMP L ALLUMEUR POMPE AIR L ALLUMEUR VENTILATEUR DE COMBUSTION MOTEUR DE L AGITATEUR 1 TR MIN ramea Jac pem s emer i e cung MOTEUR D ALIMENTATION 2 4 TR MIN CAPTEUR THERMIQUE FIL DE MISE LA TERRE VERT LIGNE DE 120 VOLTS U VENTILATEUR D AIR AMBIANT PANNEAUX DE COMMANDE CPM CB07 CPM 07A ATTENTION TENSION DE 120 VOLTS EXPOS E D BRANCHEZ L ALIMENTATION LECTRIQUE LES PI CES CHAUDES MOBILES PEUVENT CAUSER DES BLESSURES N UTILISEZ PAS L APPAREIL SANS LE PANNEAU LE CAPTEUR THERMIQUE NE CONSTITUE PAS UNE MISE LA TERRE TUYAU DE L ASPIR HAUTE TEMP LA POMPE AIR l ALLUMEUR INTERRUPTEUR DE L ASPIRATEUR TUYAU DE L ASPIR HAUTE TEMP AU C T GAUCHE DU FEU CPM CBO7A CAPTEUR THERMIQUE INTERRUPTEUR DE S CURIT DU COUVERCLE DE LA TR MIE FONCTIONS DE LA CARTE DE CIRCUITS COMPOSANT MISE EN MARCHE ARR T Ventilateur d vacuation Agitateur D marrage imm diat combustion Trois minutes apr s la mise en marche l agitateur commencera tourner Fonctionnera jusqu l arr t L arr t se fera lo
46. ENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE GUIDE DE D PANNAGE AVERTISSEMENT POUR EVITER LES CHOCS ELECTRIQUES DEBRANCHEZ TOUJOURS L APPAREIL DE L ALIMENTATION AVANT D EFFECTUER N IMPORTE QUELLE R PARATION SI VOUS NE TROUVEZ PAS DE SOLUTION VOTRE PROBL ME DANS LE PR SENT GUIDE COMMUNIQUEZ AVEC VOTRE REVENDEUR OU AVEC NOTRE SERVICE DE SOUTIEN TECHNIQUE AU 1 800 245 6489 Probl me Cause Seu La vis de calage est desserr e L engrenage du moteur est en mauvais tat granules ne tourne pas Une mati re trang re se trouve dans la vis granules pteur de l aspirateur 2 Odeurde fum e ou poussi re dans la maison 3 Leventilateur 1 Lecapteur thermique est l che d air ambiant ne 2 Le ventilateur fonctionne mal fonctionne pas 4 Le ventilateur 1 Un fil est mal raccord d vacuation ne fonctionne 2 Le ventilateur fonctionne mal 5 Flammes peu 1 intenses Les 2 flammes du feu sont peu 3 intenses 4 orange ou le 5 6 7 8 9 R glages du panneau de commande Le ventilateur d vacuation fonctionne mal Granules excessivement humides Quantit de cendres excessive Granules de qualit inf rieure combustible s accumule dans le pot de combustion La vitre peut devenir sale La porte de verre n est pas ferm e et sc
47. ETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Control Board The Control Board Part CPM CBO7 is a digital read out board This board offers a wide variety of settings to operate the unit This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove The rear access panel should be removed prior to removing the control board A 6 amp quick blow fuse is used on this Control Board See safety notes below diagram NOTE The bottom three control buttons are preset at the factory and should not require any changes See Operating Instructions and Daily Operation section of the manual for instructions on other Control Board settings Recommended Heat Ranges Low Burn Heat Range setting 1 Room Air Blower setting 1 Medium Low Heat Range setting 2 3 Room Air Blower setting Medium High Heat Range setting 4 8 Room Air Blower setting High Burn Heat Range setting 9 Room Air Blower setting 9 NOTE Blower Speed will automatically be adjusted to the desired Heat Range that you select HEAT BLOWER ical RANGE SPEED LED READ OUT Room Air Blow er CFM 1 LOW Fue Feed Display to 9 High Adjustment for Adjustment for Increas e Fuel Feed Increase Blow er CFM Adjustment for Adju
48. HE FRONT AND 6 INCHES TO EACH SIDE OF THE FUEL OPENING SEE OWNER S MANUAL FOR ADDITIONAL CLEARANCE INFORMATION BACKWALL SIDEWALL CORNER FLOOR PROTECTION 36 X 49 A 3INCHES 76 2 MM B 6 INCHES 152 4 MM C 45 INCHES 114 3 MM D 6 INCHES 152 4 MM ALCOVE 6 TO SIDE WALL 6 TO BACK WALL 66 MINIMUM FLOOR TO CEILING CAUTION OPERATE THIS UNIT ONLY WITH THE FUEL HOPPER LID CLOSED FAILURE TO DO SO MAY RESULT IN EMISSION OF PRODUCTS OF COMBUSTION FROM THE HOPPER UNDER CERTAIN CONDITIONS MAINTAIN HOPPER SEAL IN GOOD CONDITION DO NOT OVERFILL THE HOPPER HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS i MANUFACTURED BY ENGLAND STOVE WORKS P O BOX 206 MONROE VA 24574 You may write your unit s Manufacture Date and Serial Number in the blank spaces on this sample tag for future reference This sample tag also shows the safety info such as UL testing standard etc for your local officials or anyone else who may need reference information 33 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Have this information on h
49. IEN TECHNIQUE D GAGEMENTS DES TERMINAISONS DES VENTS A D GAGEMENT D AU MOINS 1 21 M EN DESSOUS OU SUR LE C T DE TOUTE PORTE OU FEN TRE POUVANT S OUVRIR B D GAGEMENT D AU MOINS 0 3 M AU DESSUS DE TOUTE PORTE OU FEN TRE POUVANT S OUVRIR C D GAGEMENT D AU MOINS 0 60 M DE TOUT B TIMENT VOISIN D D GAGEMENT D AU MOINS 2 13 M PARTIR DU NIVEAU DU SOL LORSQUE L INSTALLATION JOUXTE LA VOIE PUBLIQUE E D GAGEMENT D AU MOINS 0 60 M AU DESSUS DES HERBES DES PLANTES ET DE TOUT AUTRE MAT RIAU COMBUSTIBLE F D GAGEMENT D AU MOINS 0 91 M DE LA PRISE D AIR PAR VENTILATION FORC E D UN APPAREIL QUEL QU IL SOIT G D GAGEMENT D AU MOINS 0 60 M EN DESSOUS DES AVANT TOITS OU DES SAILLIES H D GAGEMENT D AU MOINS 0 3 M DES MURS FAIT DE MAT RIAUX COMBUSTIBLES D LA SORTIE D VACUATION D UN SYSTEME DE VENTILATION COMPORTANT DES ASPIRATEURS MECANIQUES DOIT DEPASSER D AU MOINS 30 48 CM 12 PO LA ZONE OU CE SYSTEME DE VENTILATION TRAVERSELE TOIT Notes sur les extr mit s de tuyau de conduit pour po le granules Consulter aussi le chapitre SYSTEME DE CONDUIT DE FUM E 1 plus de 0 91 m au dessus d une entr e d air forc situ dans les 3 04 m 2 plus de 1 21 m sous ou horizontalement ou plus de 3 04 m au dessus d une porte d une fen tre ou d une entr e d air par gravit dans un b timent 3 plus de 0 6 m d un b timent adjacent et plus de 2 13 m au dessus du niveau des trottoir
50. INE La garantie limit e du fabricant couvre les l ments ci dessous Cinq ans 1 Les joints d acier au carbone et les joints soud s du foyer sont garantis pendant 5 ans contre la fissuration 2 La porte et les charni res en fonte sont garanties pendant 5 ans contre le fendillement Unan 3 Les pi ces telles que la tr mie la vis granules le pot de combustion le d flecteur les axes ou les coupleurs de la vis granules les paliers de la vis granules et les fixations sont garanties pendant 1 an contre les fissures les brisures et le fendillement des joints soud s 4 Les composants lectriques le panneau en fibres de brique les accessoires le verre et la surface peinte du po le sont garantis pendant 1 an partir de la date d achat Conditions et exclusions Les dommages caus s par un emballement annulent votre garantie Cette garantie ne s applique pas si les dommages d coulent d un accident d une manipulation inad quate d une installation inad quate d une utilisation inad quate d un usage abusif d une r paration non autoris e ou d une tentative de r paration non autoris e Le fabricant n est pas responsable des dommages indirects accessoires ou cons cutifs d coulant du produit y compris les co ts ou d penses la fourniture de mat riel de rechange ou la r paration pendant les p riodes de mauvais fonctionnement ou de non utilisation du produit Le fabricant d clinera toute responsabilit po
51. ING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS I MODEL 10 CPM 9 TRCPM 49 SHCPM MANUFACTURED DATE CT T4 SERIAL NO WIN 14374 PELLET FUEL ROOM HEATER ALSO FOR USE IN MOBILE HOMES TESTED TO UL 1482 ASTM E 1509 ULC S627 ELECT RATING 120V 60HZ 5 5A PREVENT HOUSE FIRES v INSTALL AND USE ONLY IN ACCORDANCE With THE OWNER S MANUAL PROVIDED WITH THIS APPLIANCE CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA FOR USE WITH WOOD PELLETS CORN CHERRY PITTS ONLY WOOD PELLETS MUST BE 1 4 INCH IN DIAMETER DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE KEEP VIEWING AND ASH REMOVAL DOORS TIGHTLY CLOSED DURING OPERATION INPUT RATING PELLETS 4 5 LBS HR INPUT RATING CORN 4 7 LBS HR INPUT RATING CHERRY PITS 3 5 LBS HR THIS UNIT MUST BE INSTALLED WITH TYPE L CORN VENT PIPE MEETS EPA PARTICULATE MATTER REQUIREMENTS FOR WOOD HEATERS BUILT AFTER JULY 1 1990 INSTALLATION REQUIREMENTS REFER TO LOCAL CODES AND THE CHIMNEY MANUFACTURER S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING PLACE ON NON COMBUSTIBLE FLOOR PROTECTION WITH A MINIMUM R VALUE OF X WHICH EXTENDS 6 INCHES TO T
52. INSTALLATION amp OPERATION MANUAL MODEL NUMBERS 10 CPM 49 TRCPM 49 SHCPM Thank you for purchasing this product from a fine line of heating equipment We wish you many years of safe heating pleasure with your new heating appliance Save These Instructions IMPORTANT IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER CONTACT TECHNICAL SUPPORT 1 800 245 6489 Mobile Home Use These freestanding Pellet Corn Multi fuel units are approved for mobile home or doublewide installation with outside combustion air hook up See Flue System section of manual Mobile home installation should be in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 WARNING Do Not Install in Sleeping Room CAUTION The structural integrity of the mobile home floor wall and ceiling roof must be maintained Please Note the Following Precautionary Statements NOTE WE DO NOT RECOMMEND PELLET CORN MULTI FUEL STOVES AS YOUR ONLY SOURCE OF HEAT England s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product including this unit Follow all manufacturers instructions when using smoke or Carbon Monoxide detectors CAUTION Please read this entire manual before installation and use of this Pellet Corn Multi fuel burning room heater Keep children furniture fixtures and all combustibles away from any heating appliance WARNING USE OF OUTSIDE AIR
53. IS MANDATORY WITH THIS UNIT DO NOT OPERATE UNIT WITH HOPPER OPEN LID MUST BE SHUT AND TIGHTLY SECURED DO NOT OPERATE WITH DOOR OPEN SAFETY NOTICE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH FOR YOUR SAFETY AND PROTECTION FOLLOW ALL THE INSTALLATION INSTRUCTIONS CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS FOR RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS INCLUDING PERMITS IN YOUR AREA Questions Need Parts or Options www heatredefined com TER TE es cV Jus Spock we Rev 3 2015 A letter from our Technical Support department Thank you for purchasing this fine product from England s Stove Works England s Stove Works was started and is still owned by a family that believes strongly in a Do It Yourself spirit that s one reason you found this product at your favorite Do It Yourself store We intentionally design and build our stoves so that any homeowner can maintain his or her unit with basic tools and we re always more than happy to show you how to do the job as easily and as inexpensively as possible From our free downloadable service sheets to our detailed Service Videos to our new wizard style click through Troubleshooting guide on our web site we have always tried to help our customers stay heat ready especially while oil and electricity prices continue to skyrocket Please look at our vast Help section on our web
54. IVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE AVERTISSEMENT Pour les granules et le ma s lorsque vous appuyez sur le bouton Air On Temp temp rature de l air entrant situ au bas du panneau de commande vous devez vous assurer que l cran de la vitesse du ventilateur affiche le chiffre 1 L agitateur doit fonctionner en mode de combustion de granules et de mais mode 1 granules mode 5 mais Consultez la section Proc dure de changement de combustible la page 17 Comme indiqu pr c demment vous pouvez arr ter l agitateur en appuyant sur le bouton Air On Temp temp rature de l air entrant puis en appuyant sur les fl ches orient es vers le bas qui sont associ es la vitesse du ventilateur et la plage de chaleur jusqu ce que l cran affiche le chiffre 0 Avant de remettre l appareil en marche vous devez vous assurer que l cran associ la vitesse du ventilateur affiche le chiffre 1 consultez la page pr c
55. KS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE PROC DURE D ARR T AVERTISSEMENT N ARR TEZ JAMAIS CET APPAREIL EN LE D BRANCHANT DE LA SOURCE D ALIMENTATION Consultez les instructions suivantes Appuyez sur la commande tactile OFF pour mettre le po le en mode Arr t Les lettres S D apparaitront sur les crans d affichage associ s la plage de chaleur et la vitesse du ventilateur pendant que l appareil s teint pour le confirmer A ce moment la lumi re rouge situ e au dessus de la commande OFF s allumera Lorsque la commande OFF est touch e la vis granules arr te instantan ment d alimenter son tube en combustible mais le ventilateur d air ambiant le ventilateur d vacuation et l agitateur fonctionnent toujours Lorsque la temp rature interne descend 35 C le ventilateur d air ambiant s arr te et lorsque la temp rature interne descend 32 2 C le ventilateur d vacuation s arr te La lumi re s teindra et tout le po le s arr tera Plus la temp rature de l appareil est lev e plus il faut de temps pour que le po le termine le cycle d arr t Remarque L appareil mettra fin au cycle d arr t si vous appuyez sur le bouton ON au cours du cycle REMARQUE Si
56. LATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE SYST ME DE CONDUIT DE FUM E Attention Suivez les instructions du fabricant du tuyau pour l installation et les instructions pour le faire passer travers un mur ou un plafond combustible Veuillez consulter les codes locaux de votre r gion REMARQUE Consultez le sch ma de l installation fourni plus loin dans le pr sent guide illustration 1 Cet appareil est dot d un syst me tirage n gatif qui tire l air de combustion au travers du pot de combustion et pousse l air vici l ext rieur de l habitation Si l appareil n est pas raccord au syst me de conduit de fum e selon les directives du pr sent guide il ne fonctionnera pas ad quatement Pour chacun de ces types d installations gardez l esprit que chaque coude r duit jusqu 30 du tirage il est conseill d ajouter une hauteur de 3 pi de tuyau pour chaque coude qu il comporte Exemple Apr s le deuxi me coude ajoutez 1 82 m de hauteur avant de terminer le tuyau de ventilation Tuyau de ventilation pour po le mais Le tuyau de ventilation pour po le mais homologu par UL que nous recommandons est dot d un syst me de verrouillage par rotation mais il est tout de m me recommand de sceller tous les raccords l aide de silicone r sistant aux temp ratures lev es notre num ro de pi ce AC RTV3 ou de ruban conduits en
57. LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE GUIDE DE D PANNAGE AVERTISSEMENT POUR VITER LES CHOCS LECTRIQUES D BRANCHEZ TOUJOURS L APPAREIL DE L ALIMENTATION AVANT D EFFECTUER N IMPORTE QUELLE R PARATION SI VOUS NE TROUVEZ PAS DE SOLUTION VOTRE PROBL ME DANS LE PR SENT GUIDE COMMUNIQUEZ AVEC VOTRE REVENDEUR OU AVEC NOTRE SERVICE DE SOUTIEN TECHNIQUE AU 1 800 245 6489 Probl me Cause Solution 6 Un fusible 6 amp res a 1 Surtension Remplacez le fusible utilisez un parasurtenseur saut 2 Fil d nud V rifiez s il y a des fils d nud s ou des c bles dont la gaine protectrice est abim e et des fils mal branch s 3 Le moteur lectrique est court V rifiez si des l ments bloquent ou obstruent les circuit ou coinc moteurs et les ventilateurs 1 Granules de qualit inf rieure Utilisez du combustible de premi re qualit granules 2 Panneau d r g l V rifiez les r glages du panneau de commande 2 Ventilateur bruyant Retirez et huilez le ventilateur V rifiez que le ventilateur est libre d obstructions 2 La vis de calage est desserr e V rifiez la vis de la roue du
58. NIT PRIOR TO ANY SERVICE WORK 29 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Adjusting your Hopper Lid Latch The seals around the top of the pellet hopper are important to safe and efficient operation of the unit The latch installed on these units is designed to pull the hopper lid tight against this seal Over the course of operation as these seals wear in and compress the tension of the latch should be tested periodically and adjusted if necessary To adjust the lid latch the following tools will be needed two 1 2 inch wrenches or a 2 inch wrench and a 2 inch socket Unit should be unplugged and cooled down as with all maintenance In order to adjust the latch first open the hopper lid and then lock the latch in its closed position Then take the 1 2 inch wrench and loosen the nut closest to the latch This nut is then adjusted closer to the lid itself to tighten the latch After adjusting this nut to the desired location hold this nut in place with the 1 2 inch wrench the tighten down the holding nut on the end of the latch shaft with the Ye inch socket or second wrench to hold the latching assembly in place After tight
59. NSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE ENREGISTREMENT DE LA GARANTIE sur les produits England s Stove Works Renseignements sur l acheteur I Nom de l acheteur Il Adresse Il Ville Province Code postal IV Num ro de t l phone V Courriel Renseignements sur le d taillant VI Nom du d taillant VII Adresse VII Ville Province Code postal Renseignements sur l appareil IX Num ro de mod le Date d achat X Prix d achat XI Num ro de s rie Date de fabrication Questions relatives l achat Comment avez vous entendu parler de notre produit Veuillez cocher l une des r ponses suivantes De bouche oreille D monstration Internet Autre quel endroit vous a t on donn des renseignements sur notre produit Au t l phone Chez un d taillant nom du d taillant Internet Autre AVIS IMPORTANT POUR QUE LA PR SENTE GARANTIE SOIT VALIDE NOUS DEVONS RECEVOIR ET CONSERVER DANS NOS DOSSIERS CETTE INFORMATION RELATIVE L ENREGISTREMENT VEUILLEZ NOUS ENVOYER CETTE INFORMATION DANS LES TRENTE 30 JOURS SUIVANT LA DATE D ACHAT Par la poste England s Stove Works Inc Technical Support Department P O Box 206 Monroe VA 24574 Etats Unis Ou par t l copieur 1 434 929 4810 en tout temps Vous pouvez galement remplir votre enregistrement de garantie en ligne puisque ce service est maintenan
60. OLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS E Codes E Codes or Error Codes are codes that will appear in the Heat Range and Blower Speed windows of the Control Board if your unit experiences problems If you receive these codes wait until the unit is cooled completely down before trying to restart your unit If the unit continues to display any E Code s please contact Technical Support at 800 245 6489 before further attempting to restart your unit NOTE E 0 indicates No Error E 2 Fail to Start E 3 Unit Overfired If you see the E 3 code displayed on your control board you have overfired your unit You must let the unit cool and clean the Firebox and burnpot Be sure to clean the orifices holes in the burnpot You should not burn your unit on High Heat Range 9 continuously when burning corn After a couple of hours of burning corn on high turn the Heat Range to 7 and the Blower Speed to 9 WARNING Running the unit on high when burning corn for long periods can damage the unit OPERATIONAL NOTES First Fire When you push the ON button the Control Board will automatically be set at both Heat Range and Blower Speed to
61. ON Floor Protection If your floor is constructed of a non combustible material such as brick or concrete there is no need for floor protection If the floor is constructed of a combustible material such as hardwood linoleum or carpet then you will be required to use floor protection between the unit and the combustible The protection should be U L approved or equal and should be large enough to provide a minimum of six inches 6 behind and on both sides of the stove The clearance in front of the stove should be at least six inches 6 This freestanding pellet unit will need a minimum 36 x 48 floor protector Wall Protection From the rear of this stove only six inches 6 of clearance is required to paneling wallpaper or drywall we recommend more clearance for maintenance access Six inches 6 would be required to a sidewall From the corner of the stove 4 2 of clearance is required Alcoves The alcove must be a minimum of sixty six inches 66 from floor to ceiling Six inches 6 of clearance is required from the stove to an alcove sidewall six inches 6 is required to an alcove back wall The corn vent pipe would require the standard three inches 3 clearance or as recommended by the pipe manufacturer Normally additional wall protection is not required with this type unit 13 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS
62. OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS NOTE If the unit does not start or maintain a fire you will receive an E 2 in the Heat Range and Blower Speed window of the Control Board If this occurs wait until unit has cooled completely down and repeat Locking Collar IINE To remove the Stirrer for cleaning While the unit is COLD and the unit is off press and hold the AIR ON TEMP i e Air On button until the Stirrer is at the 12 00 position with the 4 prongs pointing up Pull the hitch pin marked in Illustration 3 Lifting the burnpot and Stirrer at the same time remove the Stirrer from the burnpot Clean and clear all holes in the burnpot and replace Stirrer and burnpot back into the unit NOTE When replacing the burnpot notice there is a welded piece that is always set toward the back of the Firebox Also be sure to replace the hitch pin 16 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS FUEL CHANGE PROCEDURE When starting the stove with corn push the AIR ON TEMP button and hold which will rotate the Stirrer mechanism in the burnpot Release t
63. RETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Distance des mat riaux combustibles 0 91 m Cette distance s applique galement pour les b timents voisins les cl tures les parties protub rantes de la structure la saillie de la toiture les plantes les arbustes etc L installation doit comporter un raccord en T d vacuation pour capter les cendres volantes et permettre le nettoyage p riodique du syst me d vacuation Des cendres volantes et de la suie s accumulent dans les coudes 90 degr s ce qui r duit le flux d vacuation et le rendement de l appareil Chaque coude ou raccord en T r duit jusqu 30 du potentiel de tirage La longueur totale de parcours horizontal du tuyau de ventilation ne doit pas d passer 1 21 m Lors de l installation de ce po le utilisez un TUYAU DE VENTILATION A VERROUILLAGE PAR ROTATION POUR PO LE MA S homologu par UL de 3 po et suivez les indications du fabricant concernant l installation et les distances respecter nous recommandons fortement le tuyau verrouillage par rotati
64. UF Vis granules 19 CPM RCP Couvercle lat ral droit 20 PU 047040 Moteur de l agitateur 1 tour par minute 21 CPM CB07 Panneau de commande 22 CPM CB07A Panneau de commande auxiliaire pour le mais 23 CU VS Interrupteur de l aspirateur 24 PU VH Tuyau de l aspirateur 25 AC APCPM Bac cendres 26 AC 03 Poign e du bac cendres 27 CPM BR L ou E Base et colonne 28 PU CBG Joint du ventilateur d vacuation 29 PU 076002S Ventilateur d vacuation CPM 30 CPM LCP Couvercle lat ral gauche 31 CA ATUF Ensemble du tube de vis granules 32 PU ATGUF Joint du tube de vis granules 33 CU 047042 Moteur de la vis granules 2 tours par minute 34 PU 4C447 Ventilateur de convection 35 PU HFGUF Joint de la bride de la tr mie 36 CPM RAP Panneau d acc s arri re 37 CPM HOP Tr mie 38 AC GGK Joint du couvercle de la tr mie 39 CPM HL Couvercle de la tr mie 40 PU 62 40 151 3 Loquet du couvercle de la tr mie 41 CA AMPP Plaque de montage de la vis granules 42 CA AC Raccord de la vis granules 43 AC HLS Interrupteur du couvercle de la tr mie 44 PU CH6 Allumeur 45 PU HLG Joint de la partie sup rieure de la tr mie 46 CPM PGB52 Joint d isolation du tube d vacuation 47 AC SHN Poign e a ressort en nickel bross non illustr e 48 AC SH Poign e a ressort en laiton non illustr e 49 AC DGKCPM Joint d tanch it de la porte non illustr 50 PU GP Plaque guide non illustr e 51 CU RG Joint d tan
65. UIT NI UN SYST ME DE DISTRIBUTION DE L AIR 9 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL A EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PIECES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE COMBUSTION DE MATI RES SOLIDES Vous devez retirer les cendres de l appareil p riodiquement Consultez la section Retrait des cendres Vous pouvez r duire le nettoyage n cessaire et optimiser l efficacit de votre appareil en maintenant un tirage appropri L appareil est concu pour la combustion de granules de premi re qualit de mais gren sec ou de noyaux de cerise s ch s qui r pondent aux normes du Pellet Fuel Institute PFI GRANULES DE BOIS Faites preuve de coh rence dans votre choix de fournisseur de granules de bois La composition et les caract ristiques de combustion des granules peuvent varier d un fournisseur l autre e V rifiez que vos granules ne contiennent aucun corps tranger La garantie de votre po le ne couvrira aucun dommage caus par la pr sence de corps trangers dans l approvisionnement de combustible
66. agasin pr f r de produits pr ts assembler Nous concevons et fabriquons nos po les express ment pour que n importe quel propri taire soit en mesure de les entretenir avec des outils de base De plus nous sommes toujours dispos s vous montrer comment proc der de la facon la plus simple et la plus conomique qui soit En offrant des fiches d entretien t l chargeables gratuitement des vid os d entretien d taill es et un guide de d pannage intelligent sur notre site Web nous tentons d aider nos clients tre pr ts utiliser leur appareil de chauffage en tout temps d autant plus que le prix du p trole et de l lectricit ne cesse d augmenter Si vous avez besoin d aide au sujet de votre appareil veuillez consulter la vaste section d aide de notre site Web ou appeler notre service de soutien technique au 1 800 245 6489 Nous sommes presque toujours en mesure de vous guider en cas de r paration effectuer ou de probl me ou encore de r pondre vos questions REMARQUE Les renseignements obtenus sur notre site Web ou en composant notre num ro sans frais sont gratuits en tout temps Cependant les r parations ou l entretien que nous offrons sur place occasionnent des frais Nous vous souhaitons des ann es de chauffage agr able efficace et de qualit England s Stove Works Service de soutien technique www heatredefined com 1 800 245 6489 EN CAS DE PROBLEME AVEC CET APPAREIL NE LE RETOURNEZ PAS
67. ainement Desserrez ce boulon Retirez la chaine de la roue dent e de la tige de l agitateur B REMARQUE Il peut tre n cessaire de faire tourner la tige manuellement pour acc der la vis de calage Localisez la vis de calage t te hexagonale de 5 po sur la roue dent e et desserrez la Retirez la bague de blocage de 7 4 po de la tige de l agitateur situ e l int rieur de l appareil l aide d une cl hexagonale de po D Vis de montage du moteur de 5 16 po o O1 BR ND 9 Retirez la tige en la tirant vers vous de l ext rieur du po le A Boulon de r glage de la cha ne de po Illustration 5 Moteur tige et roues dent es 23 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Joints d tanch it IMPORTANT L ENTRETIEN INAD QUAT DES JOINTS Y COMPRIS LE D FAUT DE REMPLACEMENT DES JOINTS PEUT SE TRADUIRE PAR DES FUITES D AIR CAUSANT DES RETOURS DE FUMEE Cet appareil est livr avec un j
68. all for heat leaves at which point the stove goes to the Low heat range setting To set the stove in the High Low mode unplug the unit and plug it back in then press and release both down arrows H L appears in the heat range and blower speed windows The unit is now in High Low mode Note Repeat this to change back to On Off mode a 0 0 will appear in the heat range and blower speed windows Using a thermostat in On Off mode may shorten the life of your stove s igniter Please note Certain units may not respond to this if your unit does not respond in this manner please contact Technical Support at 800 245 6489 AC 109 AC 109BN Lip Trim There is one piece of J Channel trim that snaps onto the ash apron Remove the protective covering from the trim and force the piece onto the edge Although it should stay in place stove cement can be used to secure it if necessary ACCESSORIES AND OPTIONS PART NUMBER PART DESCRIPTION PU OAK Outside Air Kit Now included with unit AC 33000 3 Corn Vent Kit Through the Wall AC 33100 4 Corn Vent Kit Through the Wall PU DTSTAT Wall Thermostat AC 3003 Remote Thermostat AC 109 Brass Lip Trim AC 109BN Brushed Nickel Lip Trim AC MBSP High Temp Spray Paint Replacement Parts Accessories and Options can be ordered from the factory at Parts orders ONLY 800 516 3636 or on our web site ww w heatredefined com If you have any questions or problems contact the Technical Suppo
69. and if you phone the factory or your dealer regarding this product Retain for your files Model Number Date of Purchase Date of Manufacture Serial LIMITED 5 YEAR WARRANTY FROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER The manufacturer extends the following warranties Five Year Period 1 Carbon steel and welded seams in the Firebox are covered for 5 years against splitting 2 The cast iron door and hinges are covered for 5 years against cracking One Year Period 3 Component parts such as the hopper auger burnpot baffle plate auger shafts and or couplers auger bearings and fasteners are covered for 1 year against cracking breakage and welded seams from separating 4 Electrical components brick fiber board accessory items glass and the painted surface are covered for 1 year from the date of purchase Conditions and Exclusions Damage from over firing will void your warranty This warranty does not apply if damage occurs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product including any cost or expense providing substitute equipment or service during periods of malfunction or nonuse All liability for any consequential damage for breach of any written or implied warranty is disclaimed and excluded Some states do no
70. ans le pr sent guide Consultez les illustrations pour l installation du pot de combustion AVIS IMPORTANT L appareil doit tre correctement install pour pr venir les risques d incendie ou de retour de fum e Les instructions doivent tre rigoureusement respect es N ayez pas recours des exp dients ou des pi ces de moindre qualit pouvant compromettre l installation Votre appareil n cessite un entretien et un nettoyage p riodiques consultez le guide Un mauvais entretien de l appareil peut causer divers probl mes y compris sans toutefois s y limiter la propagation de fum e dans la maison England s Stove Works n est pas responsable des dommages accessoires ou cons cutifs relatifs des biens ou des personnes r sultant de l utilisation de ce produit 4 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL A EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PIECES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE PR PARATION DE L APPAREIL 1 Fixez la poign e ressort la porte en la tournant dans le sens contraire des aiguilles
71. ateur consultez les illustrations 3 et 4 de la page 16 N utilisez pas l agitateur lorsque vous br lez des noyaux de cerise 2 Vous devez r initialiser le panneau de commande pour br ler des noyaux de cerise D branchez l appareil puis rebranchez le Ensuite appuyez en m me temps sur les fl ches orient es vers le haut et le bas qui sont associ es la vitesse du ventilateur et rel chez les Appuyez sur la fl che orient e vers le haut associ e la plage de chaleur jusqu ce que l cran affiche le chiffre 6 Attendez que le chiffre s efface N oubliez pas de retirer l agitateur page 16 R glez le bouton Air On Temp temp rature de l air entrant 0 consultez la page 15 premier paragraphe Vous tes maintenant pr t br ler des noyaux de cerise Pour revenir au mode de combustion de mais Appuyez sur la fl che orient e vers le bas associ e la plage de chaleur jusqu ce que s affiche le chiffre 5 Attendez que le chiffre s efface Vous tes maintenant pr t br ler du mais Pour revenir au mode de combustion de granules Appuyez sur la fl che orient e vers le bas associ e la plage de chaleur jusqu ce que l cran affiche le chiffre 1 Attendez que le chiffre s efface Vous tes maintenant pr t br ler des granules N oubliez pas de remettre l agitateur en place et de le r gler pour qu il soit en marche lorsque vous br lez des granules ou du mais consultez la section
72. ation and grade three feet 3 ft minimum This is conditional upon the plants and nature of the grade surface The exhaust gases are hot enough to ignite grass plants shrubs etc located in the vicinity of the termination The grade must not be a lawn Distance from bottom of termination and public walkways is seven feet 7 ft minimum e Distance to combustible materials three feet 3 ft This includes adjacent buildings fences protruding parts of the structure roof overhang plants and shrubs etc e The installation must include a cleanout tee to enable the collection of fly ash and permit periodic cleaning of the exhaust system 90 elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the unit Each elbow or tee reduces draft potential by up to 3096 8 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS e Total length of horizontal vent must not exceed 48 4 ft Use three inch 3 U L approved CORN VENT TWIST LOCK PIPE when installing this stove and follow the manufacturer s specifications for installation and clearances we highly recommend Dura Vent corn twist lock pipe our Part Number A
73. auffage Conservez les pr sentes instructions IMPORTANT EN CAS DE PROBL ME AVEC CET APPAREIL NE LE RETOURNEZ PAS AU DETAILLANT COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE AU 1 800 245 6489 Utilisation dans une maison mobile L utilisation de ces appareils autoportants granules mais et multicombustibles est approuv e pour des maisons mobiles ou pour une installation en double largeur avec raccordement l ext rieur pour l air de combustion Consultez la section Syst me de conduit de fum e du pr sent guide L installation dans une maison mobile doit tre conforme la norme Manufactured Home and Safety Standard HUD CFR 3280 partie 24 des Etats Unis AVERTISSEMENT N installez pas l appareil dans une chambre coucher ATTENTION L int grit structurelle du plancher des murs du plafond et du toit de la maison mobile doit tre pr serv e Veuillez prendre note des pr cautions suivantes REMARQUE NOUS RECOMMANDONS DE NE PAS UTILISER CES PO LES AUTOPORTANTS GRANULES A MA S ET MULTICOMBUSTIBLES COMME UNIQUE SOURCE DE CHALEUR England s Stove Works recommande fortement l utilisation de d tecteurs de fum e et de monoxyde de carbone avec tout appareil de chauffage y compris celui ci Suivez toutes les instructions du fabricant lorsque vous utilisez des d tecteurs de fum e et de monoxyde de carbone ATTENTION Veuillez lire l int gralit du pr sent guide avant d installer et d ut
74. avec un tuyau de ventilation pour po le mais de type L Conforme aux exigences de L EPA en mati re d missions de particules pour les po les bois fabriqu s apr s le 1 juillet 1990 EXIGENCES RELATIVES L INSTALLATION Reportez vous la r glementation locale et aux instructions du fabricant de la chemin e pour connaitre les pr cautions prendre si vous faites passer une chemin e au travers d un mur ou d un plafond combustible Disposez un protecteur de plancher incombustible avec une valeur d isolation thermique R minimale de X qui d passe de 15 24 cm l avant et de chaque c t de l ouverture pour l alimentation en granules Consultez le guide d utilisation pour en savoir plus sur les distances minimales Protection du plancher Parois arri re et lat rale 91 44 cm x 121 92 cm LI A 7 76 2 mm 3 po B 152 4 mm 6 po C 114 3 mm 4 5 po D 152 4 mm 6 po Niche 15 24 cm du mur lat ral 15 24 cm du mur arri re distance minimale de 167 64 cm du plancher au plafond ATTENTION N utilisez cet appareil qu avec le couvercle de la tr mie ferm Sinon des produits de combustion pourraient tre mis dans certaines conditions Maintenez le joint d tanch it de la tr mie en bon tat vitez de remplir la tr mie de fa on excessive ATTENTION CET APPAREIL DEVIENT CHAUD LORSQU IL EST EN MARCHE N Y TOUCHEZ PAS MAINTENEZ LE BONNE DISTANCE DES MEUBLES ET DES V TEMENTS ET HORS
75. bustible Une fois le tuyau pass l ext rieur de la structure vous devez maintenir un d gagement de 7 62 cm par rapport au mur ext rieur et installer un raccord en T d vacuation sur le tuyau qui d passe du mur Nous recommandons d utiliser un tuyau vertical d au moins 0 91 m dot d un d voiement de 90 degr s l oppos de la maison Ajoutez une section de 0 3 m et un capuchon horizontal pour terminer l installation consultez l illustration 1 Vous devez installer une bride murale en dessous de la derni re section 90 degr s pour stabiliser le syst me Si vous vivez dans une r gion qui conna t des chutes de neige abondantes il est recommand que la hauteur de l installation soit sup rieure 0 91 m pour qu elle s l ve au dessus de la neige accumul e Vous pouvez galement utiliser ce type d installation si votre po le est situ sous le niveau du sol en ajoutant la section d vacuation et le tuyau vertical l int rieur de l habitation jusqu ce que l installation d passe le niveau du sol Cependant nous recommandons que l installation en sous sol soit uniquement effectu e par un installateur professionnel Pour les installations en sous sol vous devez utiliser un tuyau et un raccord de 3 po pour l admission d air de combustion ext rieur Vous devez respecter un d gagement minimal de 0 91 m entre le sol et le tuyau de ventilation pour po le mais l ext rieur de l habitation Composez le 1 800 516 3636 pou
76. ch it en caoutchouc non illustr 52 CPM APG Joint d tanch it du bac a cendres non illustr 53 CPM AP Pompe a air non illustr e 28 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL A EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PIECES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Consultez les num ros d article de la vue clat e pour l emplacement des pi ces Vue clat e pour l emplacement des pi ces du 10 CPM Illustration 8 Vue clat e du po le granules au mais ou multicombustible Dimensions de votre appareil granules au mais ou multicombustible combustible multiple 70 16 cm L x 77 78 cm H x 80 64 cm P 177 35 kg Environ 45 72 cm de hauteur du plancher au centre du syst me d vacuation ATTENTION D BRANCHEZ L APPAREIL AVANT N IMPORTE QUEL ENTRETIEN 29 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT
77. cm est n cessaire entre l appareil et les murs de chaque c t partir des coins du po le un d gagement de 11 43 cm est n cessaire Alc ves La distance minimale entre le plancher et le plafond de l alc ve doit mesurer 167 64 cm Un d gagement de 15 24 cm est n cessaire entre le po le et les murs lat ral et arri re d une alc ve Vous devez respecter le d gagement standard de 7 62 cm autour du tuyau de ventilation pour po le mais ou le d gagement recommand par le fabricant du tuyau Normalement une protection murale suppl mentaire n est pas n cessaire avec ce type d appareil 13 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE MODE D EMPLOI ATTENTION NE PAS UTILISER CET APPAREIL AVEC LA PORTE OUVERTE Ne br lez pas de d chets sacs en papier etc dans cet appareil Ce po le est muni d un syst me de tirage par aspiration et est concu pour fonctionner de facon continue puisqu il n est pas n cessaire de l teindre fr quemm
78. construction ou le service d incendie afin de conna tre les restrictions et les exigences relatives l installation dans votre r gion si vous avez des questions e Avant de brancher votre appareil lisez les sections Fonctionnement et Combustibles du pr sent guide e D branchez toujours l appareil avant de l entretenir e Neraccordez pas l appareil un conduit de fum e d j utilis pour un autre appareil e Lorsque vous installez le tuyau de po le l appareil il est important de se rappeler que l appareil fonctionne en pression n gative et la chemin e en pression positive Tous les raccords et les coudes du tuyau de po le doivent tre tanches l air Les pratiques de ventilation ad quate doivent tre respect es Faites appel un professionnel de la ventilation e Les cendres doivent tre jet es dans un contenant m tallique dot d un couvercle herm tique e Toutes les indications relatives aux distances minimales des mati res combustibles doivent tre respect es e est important d utiliser un combustible propre sec et uniforme Nous vous recommandons de vous procurer tout votre approvisionnement de combustible pour la saison de chauffage en une seule fois pour assurer son uniformit e Trois diff rents combustibles ont t test s pour cet appareil en mai 2007 Si vous avez des questions au sujet du combustible que vous tentez d utiliser communiquez avec notre service de soutien techn
79. ction de votre taux de combustion vous devez retirer r guli rement les cendres accumul es dans le pot de combustion L espace gauche et droite du pot de combustion sert contenir les cendres nettoyez r guli rement les trous d a ration du pot de combustion pour une combustion plus efficace V rifiez le syst me d vacuation r guli rement Consultez la section Retrait et limination des cendres 3 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL A EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PIECES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE 12 13 14 15 16 17 18 19 20 21 22 Gardez le ma s les granules et tout autre mat riau combustible une distance s curitaire de l appareil Un protecteur de plancher est n cessaire si l appareil est pos sur une surface combustible Le protecteur de plancher doit couvrir une superficie minimale de 91 44 cm x 121 92 cm ce qui laisse un espace de protection d au moins 15 24 cm l avant l arri re et de chaque c t de l appareil La longueur ho
80. d over the edge Fold the gasket edges over on the glass forming a U shape You should also replace the Combustion Blower gasket Part PU CBG whenever you remove or clean the Combustion Blower In addition the Hopper Lid gasket and Ash Pan gasket should be inspected and replaced annually or sooner if necessary Finish This new unit has been painted with High Temperature Paint that should retain its original look for years If the unit should get wet and rust spots appear the spots can be sanded with plain steel wool and repainted We recommend High Temperature Spray Paint Part AC MBSP as others may not adhere to the surface or withstand the high temperatures Glass This unit has a ceramic glass Part AC G20 comes with gasket in the viewing door Surface scratches are acceptable but if this glass becomes cracked in any area the unit should be shut down and the window replaced with this high temperature ceramic glass If you have any questions or problems contact the Technical Support Department Technical Support Department service Denglanderstoves com P O Box 206 Parts Orders ONLY 800 516 3636 Monroe VA 24574 Questions 800 245 6489 Fax 434 929 4810 You may also order parts and options view frequently asked questions and more on our Web Site www heatredefined com 24 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASK
81. d un grain de mais dur entre autres Un bruit peut retentir au moment de mettre l appareil en marche mais il cessera une fois l appareil chauff L appareil ne sera pas endommag Ce syst me robuste en acier inoxydable est con u pour vous offrir de nombreuses ann es de fonctionnement sans probl me LE PO LE N EST PAS ALIMENT AD QUATEMENT EN COMBUSTIBLE Si le po le n est pas aliment ad quatement en combustible il est possible que la vis d alimentation des granules soit mal align e en raison de facteurs tels qu une manipulation sans pr cautions lors du transport Si vous croyez que la vis granules est mal align e communiquez avec le service de soutien technique au 1 800 245 6489 D marrage automatique Lorsque vous appuyez sur le bouton ON marche pour effectuer un d marrage froid l appareil est en mode d marrage pour le confirmer le code S U s affichera apr s 3 secondes sur les crans associ s la plage de chaleur et la vitesse du ventilateur Dans ce mode qui dure 20 minutes 30 minutes pour le mode de combustion de mais la plage de chaleur de l appareil est pr r gl e pour emp cher l appareil de surchauffer Durant cette p riode de d marrage vous pouvez ajuster le r glage du panneau de commande comme vous le souhaitez Une fois le d marrage termin l appareil fonctionnera selon le r glage personnalis Allumer votre appareil manuellement Si le d marrage automatique ne fonctionne
82. d une montre Important V rifiez galement que le loquet de la tr mie est ferm solidement de sorte que la partie sup rieure soit scell e et emp che un retour de feu 2 Testez le courant de votre prise de 110 volts puis branchez l appareil Elle doit tre d au moins 15 A ou de 20 A si le circuit est prot g par un disjoncteur diff rentiel Puisque l appareil possede un panneau de commande lectronique nous vous recommandons fortement d utiliser un parasurtenseur 3 Assurez vous de faire fonctionner votre appareil vide pendant 20 minutes avant de le raccorder au conduit de fum e Pendant cette p riode de 20 minutes les ventilateurs et la vis granules fonctionneront diff rents moments l appareil devrait s teindre apr s 20 minutes ou apr s 30 minutes pour la combustion de mais Visitez notre site Web au www heatredefined com pour obtenir des renseignements pratiques consulter la foire aux questions commander des pi ces ou des accessoires et plus encore RENSEIGNEMENTS IMPORTANTS LISEZ AVANT L UTILISATION e Lors de l installation de votre po le a granules mais et multicombustible des pr cautions particuli res en mati re de protection contre le feu doivent tre prises Une mauvaise installation de l appareil pourrait provoquer un incendie Pour votre s curit suivez les instructions pour l installation et l utilisation fournies et communiquez avec les autorit s locales en mati re de
83. d until completely cooled and free of hot cinders Once the ash is removed the burnpot should be given a thorough inspection Remove and clean the burnpot See page 15 Check for any build up in the front of the burn area Clean out all air holes these air holes should be kept clean as they supply combustion air under and around the fuel The Cradle assembly in which burnpot rests should also be thoroughly cleaned IMPORTANT Ash build up can cause the unit to malfunction Monthly Ash Maintenance NOTE The Monthly Ash Removal maintenance should include the steps listed in this section as well as the steps listed in the Semi Weekly AND the Daily Ash Maintenance sections Use a screwdriver or chisel and break any creosote build up in the front of the unit where the pellets are fed into the burnpot from the Auger Tube Also inspect your flue pipes and remove ash buildup from the clean out tee Annual Maintenance NOTE The Annual Cleaning maintenance should include the steps listed in this section as well as the steps listed in the Monthly Semi Weekly AND the Daily Ash Maintenance sections The stove and the flue system should be given a complete cleaning at the end of the heating season Remove the burnpot See page 15 clean it thoroughly and re install it In addition to the cleaning mentioned for semi weekly and monthly the Combustion exhaust Blower should be removed annually and the blower tube vacuumed of any ash build up When cleani
84. ds can damage the unit Check for loose flue pipe connections Also be sure to have proper Outside Air Hook up Remove and clean Stirrer dump ash pan and clean burnpot Refill Improper air mixture can cause the unit to burn fuel faster than the auger is feeding Remove auger and clean Auger jams can be a problem if poor quality fuel is used or if excessive fines sawdust corn cobs husks etc are present in hopper Auger jams are evidenced when the auger turns but no fuel is delivered Check to see if auger motor is turning and auger is not NOTE Auger is held to the auger motor by a coupler that is fastened to the auger motor with a setscrew If coupler is loose remove the auger motor and tighten setscrew in the coupler Lid ajar or open debris under hopper seal Evident when the unit is extremely hot Reduce Heat Range by 1 Check blower clean or replace as necessary Clean any blockage from venting Too many elbows in the venting restrict air flow causing vacuum switch to open Inspect connection and replace if necessary Improper installation may cause a back draft NOTE Also check for loose or cracked vacuum hose on vacuum switches see Parts Diagram NOTE Negative pressure in a home is a serious issue This unit must be installed with the Outside Air Kit Part PU OAK CAUTION UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK 32 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUD
85. ds or material which may compromise the installation Your unit requires periodic maintenance and cleaning refer to manual Failure to maintain your unit may lead to a variety of problems including but not limited to smoke spillage into the home England s Stove Works will not be liable for consequential or indirect damages to property or persons resulting from the use of this product 4 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS UNIT PREPARATION 1 Attach the spring handle to the door by turning it counterclockwise Important Also check hopper latch must be tight so that the top is sealed to prevent back burn 2 Test your 110 volt outlet for current and then plug in the unit Must be a 154A circuit minimum should be 20A if circuit is GFIC protected We highly recommend a surge protector for our unit as the control panel is electronic 3 Be sure to dry run your unit for 20 minutes before connecting it to the flue During this time the blowers and auger will operate at different times throughout the 20 minute period it should stop automatically after 20 minutes 30 minutes for corn Visit our web site at ww w heat
86. e stove should automatically shut itself off after the 20 minute dry run Corn is a 30 minute cycle 4 If burning pellets you should use Premium Pellets as this stove is designed for Premium Pellets Pellets with high ash content will burn dirty and require the unit to be cleaned more often 5 If burning corn you should use corn with less than 14 moisture content Corn with high moisture content will burn dirty and require the unit to be cleaned more often 6 If burning cherry pits you should use cherry pits with less than 496 moisture content Cherry pits with high moisture content will burn dirty and require the unit to be cleaned more often 7 Be sure your corn cherry pits or pellets are not damp or wet If your fuel is too damp this stove may not be able to run on the lower Heat Range settings the fire will die out Be sure to keep sawdust debris and fines out of the unit 8 Use three inch 3 U L approved CORN VENT TWIST LOCK PIPE when installing this stove and follow the manufacturer s specifications for installation and clearances we highly recommend Dura Vent corn twist lock pipe our Part Number AC 33000 Even though this pipe interlocks it is recommended to seal all connections with high temperature silicone our Part Number AC RTV3 or aluminum duct seal tape Use at least three screws to secure the pipe to this units exhaust blower Also if you do not use U L approved twist lock corn pipe be sure to use U L
87. e de chaleur jusqu ce que l cran affiche le chiffre 5 Attendez que le chiffre s efface Vous tes maintenant pr t br ler du mais Pour revenir au mode de combustion de granules Appuyez sur la fl che orient e vers le bas associ e la plage de chaleur jusqu ce que l cran affiche le chiffre 1 Attendez que le chiffre s efface Vous tes maintenant pr t br ler des granules 2 Suivez les instructions relatives l allumage Passer des granules aux noyaux de cerise Votre appareil est principalement concu pour la combustion de granules mais peut galement servir la combustion de noyaux de cerise s ch s Assurez vous que votre fournisseur vend des noyaux de cerise s ch s destin s servir de combustible pour les po les granules N utilisez pas de noyaux de cerise con us pour les activit s artisanales ou r cr atives puisque les noyaux de ce genre sont habituellement blanchis ou trop dess ch s Par d faut votre appareil est r gl pour la combustion de granules si vous souhaitez l utiliser pour la combustion de noyaux de cerise suivez les tapes ci dessous AVERTISSEMENT N ouvrez pas la porte de l appareil si l agitateur fonctionne toujours Consultez les instructions R glage de l agitateur la page 14 du pr sent guide REMARQUE Avant d effectuer ces tapes assurez vous que l appareil est teint et compl tement refroidi avant de le nettoyer 1 Retirez la tige de l agit
88. ed and Heat Range until you see a 0 in the Blower Speed window The Stirrer may be turned back On by pressing the Air On button on the bottom of the Control Panel and then pressing both Up arrows on the Blower Speed and Heat Range until you see a 1 in the Blower Speed window This prong must be in the upright position when restarting the stove the 4 prong side is in 12 00 position Stirrer Illustration 2 CAUTION Never use gasoline lantern fuel kerosene charcoal lighter fluid diesel fuel or any other flammable liquid to start the fire Keep all combustible materials at a safe distance from stove The Heat Range and Blower Speed will automatically be set to setting 5 default setting during start up to ensure that proof of fire is detected During the 20 minute start up period the user can set the controls to a desired heat setting and after the 20 minute start up the unit will operate at that user setting When burning corn start up period is 30 minutes 14 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS WARNING For pellets and corn when the Air On button on the bottom of the Control Board is pr
89. eil ne r pond pas de cette facon veuillez communiquer avec le Service de soutien technique au 1 800 245 6489 Garniture de rebord AC 109 AC 109BN Il y a une pi ce de garniture en J qui s enclenche au tablier cendres Retirez la pellicule protectrice de la garniture et poussez la pi ce sur le rebord M me si elle devrait rester en place du ciment pour po le peut tre utilis pour la fixer si n cessaire ACCESSOIRES ET OPTIONS NUM RO DE PI CE DESCRIPTION DES PI CES PU OAK Ensemble de raccords l air ext rieur maintenant inclus avec l appareil AC 33000 Ensemble de ventilation pour po le mais de 3 po travers le mur AC 33100 Ensemble de ventilation pour po le mais de 4 po travers le mur PU DTSTAT Thermostat mural AC 3003 Thermostat avec commande distance AC 109 Garniture de rebord en laiton AC 109BN Garniture de rebord en nickel bross AC MBSP Peinture pulv riser r sistant aux hautes temp ratures Des pi ces de remplacement et des accessoires peuvent tre command es de l usine au Commandes de pi ces SEULEMENT 1 800 516 3636 ou sur notre site Web www heatredefined com Si vous avez des questions ou des probl mes communiquez avec le Service de soutien technique Technical Support Department service englanderstoves com P O Box 206 Commandes de pi ces SEULEMENT 800 516 3636 Monroe VA 24574 Etats Unis Questions composez le 1 800 245 6489 T l copieur 1 434 92
90. ell e de mani re tanche Les plaques de retrait des cendres ne sont pas enfonc es compl tement Le ventilateur d vacuation ne fonctionne pas ou le po le ne se ventile pas correctement La teneur en humidit est sup rieure 15 96 L int rieur du po le et les tuyaux d vacuation sont obstru s Lerythme d alimentation est trop lev selon le combustible utilis L air comburant disponible est inad quat Le conduit ou l entr e d air est restreint 1 Serrezla vis de calage sur le collier 2 Remplacez le moteur de la vis granules 3 Enlevez les granules et les autres sources d obstruction 4 V rifiez le ventilateur d vacuation 1 V rifiez toutes les connexions pour des fuites particuli rement le raccord du ventilateur d vacuation scellez les avec de la silicone un collier de serrage ou du ruban en aluminium 1 Resserrez le raccord sur le capteur 2 Remplacez le ventilateur 1 V rifiez les connexions sur le panneau de commande 2 Remplacez le ventilateur R visez les r glages du panneau de commande Remplacez le ventilateur 1 2 3 Gardez les granules l int rieur 4 Nettoyez l appareil 5 Utilisez des granules de premi re qualit 6 V rifiez si des l ments obstruent le flux ou l entr e d air 7T Ajustez la poign e de porte ou remplacez le joint d tanch it au besoin 8 V rifiez que les plaques de retrait des cendres sont enfonc es compl
91. ening the latch test the latch for proper tension by locking the lid down and lifting each front corner of the lid The lid should be firmly held down by the latch Repeat the same procedure if the latch is still not tight enough Latch Assembly Important Hopper Lid Latch must be checked periodically and kept tight so the top is sealed to prevent back burn GRIP RANGE MAX OUTER PANEL THICKNESS 6 25 Ea m PAWL FORWARD HOUSING NC LEVER N PAWL RETAINING CLIP LOCKWASHER L DO NOT ALTER THIS FACTORY PRE SET NUT SCREW LOCKWASHER ASS Y M5 Thread Panels thicker than 6 25 require a longer screw lockwasher combination not supplied L FLARED MOUNTING BRACKET 56 2 20 30 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS TROUBLE SHOOTING GUIDE WARNING TO AVOID ELECTRICAL SHOCK ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE ATTEMPTING ANY REPAIR IF THIS GUIDE DOES NOT CORRECT THE PROBLEM CALL YOUR LOCAL DEALER OR OUR TECHNICAL SUPPORT AT 1 800 245 6489 Problem Case Solution 1 Loose set screw 2 Bad gear motor 3 Foreign matter in auge
92. ent Le r glage de la commande tactile Heat Range plage de chaleur contr le l apport de chaleur et la quantit de combustible br l e par l appareil consultez la section Panneau de commande REMARQUE Ce po le fonctionne l aide de combustible solide et ne se remettra pas en marche automatiquement moins qu un thermostat soit install Consultez les Instructions pour le thermostat la page 27 REMARQUE La vitesse du ventilateur s ajustera automatiquement en fonction de la plage de chaleur que vous s lectionnerez PROC DURE DE D MARRAGE R GLAGE DE L AGITATEUR Avertissement N ouvrez pas la porte de l appareil si l agitateur fonctionne toujours Le non respect de cette consigne peut entra ner des blessures L agitateur doit tre r gl avant chaque utilisation de fa on ce que le c t quatre dents de l agitateur pointe vers le haut consultez le sch ma ci dessous Pour faire pivoter l agitateur appuyez sur le bouton AIR ON TEMP temp rature de l air entrant situ au bas du panneau de commande et maintenez le enfonc il cessera de tourner lorsque vous rel cherez le bouton Pour arr ter et mettre en marche l agitateur vous pouvez arr ter l agitateur en appuyant sur le bouton Air On Temp temp rature de l air entrant situ au bas du panneau de commande puis en appuyant en m me temps sur les deux fl ches orient es vers le bas qui sont associ es la vitesse du
93. erably with 11 1296 moisture content Never burn deer corn as it frequently contains molasses sugars Store your corn supply in a dry place and keep bags or container sealed to prevent your corn from absorbing excess moisture Test the moisture content regularly to ensure proper dryness IMPORTANT DO NOT BURN TREATED SEED CORN IN YOUR STOVE Seed corn is treated with chemical pesticides that are harmful or fatal if swallowed therefore seed corn is dangerous to have in the house especially where children can reach it Burning treated seed corn in your stove will void your warranty and will destroy the exhaust system on the unit CHERRY PITS Dry preferably with less than 496 moisture content Your unit was primarily designed to burn pellets but will also burn dried cherry pits Make sure your supplier is selling Dried Cherry Pits for use as fuel in pellet burning stoves IMPORTANT DO NOT use cherry pits designed for crafts or hobbies This type is usually bleached or over dried 10 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS FLUE SYSTEM Caution Follow the pipe manufacturer s installation instructions and directions for
94. es et le fil de liaison retir du panneau Ensuite les deux fils de connexion du thermostat devraient tre gliss s dans ces ouvertures et les vis serr es le fil de liaison devrait tre conserv pour un fonctionnement futur sans thermostat UTILISATION DU THERMOSTAT Ce po le est dot d une nouvelle fonction exclusive qui offre deux modes de fonctionnement avec le thermostat Le po le sort de l usine pr programm au mode marche arr t et se met en marche ou s teint en fonction de la demande de chaleur de la m me facon qu un appareil de chauffage Le second mode est le mode lev bas pour lequel la combustion s effectue en fonction du r glage de temp rature jusqu ce que l appel de chaleur cesse Par la suite le po le continue de fonctionner avec un r glage de faible chaleur Pour choisir le mode lev bas d branchez l appareil puis rebranchez le Ensuite appuyez sur les deux fl ches orient es vers le bas et rel chez les l indication H L s affichera sur les crans relatifs la plage de chaleur et la vitesse du ventilateur L appareil fonctionne alors en mode lev bas Remarque R p tez cette op ration pour revenir au mode marche arr t Les crans afficheront alors le code 0 0 L utilisation du thermostat en mode marche arr t peut r duire la dur e de vie de l allumeur de votre po le Remarque Certains appareils pourraient ne pas r pondre cette commande Si votre appar
95. essed you must make sure you see the number 1 in the Blower Speed window The Stirrer must be running in the pellet and corn modes mode 1 pellet mode 5 corn see Fuel Change Procedure page 16 As previously stated the Stirrer will stop if you press the Air On button and press the Blower Speed and Heat Range arrows down until you see a zero 0 in the window Before you restart your unit you must see the number 1 in the Blower Speed window see previous page Make sure the Stirrer is turning before you walk away from the unit The Stirrer will start 4 minutes into the startup mode It turns very slowly so you will want to observe it to make sure it is actually moving NOTE Onthe first fire the first time you burn the unit the Control Panel should be set at a 5 Heat Range and 5 Blower Speed for at least 3 hours to allow the unit to cure as the oils from the manufacturing process burn off Windows and doors in the home should be opened to help ventilate as these oils burn off NOTE Ifthe unit does not start DO NOT try to restart the unit until it has cooled completely down If the unit does not start or maintain a fire you will receive an E 2 in the Heat Range and Blower Speed window of the Control Board If this occurs wait until unit has cooled completely down and repeat these steps NOTE The burnpot and Stirrer are part of a floating system This means you will see it rise up and go down The u
96. he button when the 4 prong side of the Stirrer is straight up in the 12 00 position as shown in Illustration 2 page 13 Then follow the previous instructions concerning placing the handful of pellets in the burnpot and starting your fire Manually Starting Your Unit page 14 Changing from Pellets to Corn Your unit was primarily designed to burn pellets but will also burn corn Your unit comes ready to burn pellets by default if you would like to burn corn in your unit follow the steps below WARNING Do not open the door on this unit if the Stirrer is still moving See instructions Setting the Stirrer on page 13 in this manual NOTE Before performing these steps make sure the unit is out and completely cold 1 The control board must be reset to burn corn Unplug the unit and plug back in then press the Blower Speed up and down buttons at the same time and release You should see a 1 through 8 in the Heat Range window Push the Heat Range up arrow until you see a 5 Wait for the window to clear You are now set to burn corn To change the stove back to burn pellets Push the Heat Range down arrow until you see a 1 Wait for the window to clear You are now set to burn pellets 2 Follow lighting instructions Changing from Pellets to Cherry Pits Your unit was primarily designed to burn pellets but will also burn dried cherry pits Make sure your supplier is selling Dried Cherry Pits for use as fuel in pelle
97. ic Shutdown 26 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS ACCESSORY ITEMS The following accessories can be added to your unit at anytime after purchase however let the unit cool down before adding any accessories Thermostat An external thermostat such as our Part PU DTSTAT wall or Part AC 3003 remote can be used on our Pellet Corn Multi fuel units as long as it is a low voltage that works with millivolt systems After unplugging the unit locate the jumper wire J 18 on the bottom of the control board The two screws should then be loosened and the jumper wire removed from the board Next the two thermostat lead wires should be slipped into these openings and the screws tightened the jumper wire should be saved for future operation without a thermostat THERMOSTAT OPERATION This stove is equipped with a unique new feature that allows two options for thermostatic operation The stove comes from the factory pre programmed in On Off mode which turns the stove on and off when the call for heat comes or leaves like a furnace The second or High Low mode burns at whichever heat range you set the stove at until the c
98. ient environ 22 67 kg granules de bois et devrait tre remplie lorsque le niveau de combustible baisse 7 62 cm ou 10 16 cm Remarque Le couvercle de la tr mie sera chaud Ainsi vous devriez toujours vous prot ger les mains Ne placez JAMAIS votre main pr s de la vis granules pendant que le po le fonctionne Remarque Assurez vous que le joint du couvercle de la tr mie est toujours libre de ma s et de toutes autres granules avant de fermer Assurez vous de fermer et de verrouiller la tr mie fermement avant de rallumer le po le N utilisez pas cet appareil lorsque le couvercle de la tr mie est ouvert ou mal ferm Panne d lectricit Si l appareil manque d lectricit durant trois minutes ou moins il reprendra son fonctionnement lorsque l alimentation lectrique sera r tablie en fonction des indications suivantes tat de l appareil au moment tat de l appareil lorsque de la coupure d lectricit l alimentation est r tablie ON marche D marrage D marrage D marrage Mise hors tension Mise hors tension OFF arr t OFF arr t Si l appareil manque d lectricit pour une dur e approximative de plus de trois minutes il demeurera teint lorsque l alimentation lectrique sera r tablie Important N ouvrez NI le couvercle de la tr mie NI la porte de l appareil pendant une panne d lectricit Ouvrez la porte ext rieure la plus proche et une fen tre pour liminer le courant d air nat
99. iliser cet appareil de chauffage granules mais et multicombustible ARR T Gardez tout appareil de chauffage hors de port e des enfants et bonne distance des meubles et des mati res combustibles AVERTISSEMENT L AIR UTILIS PAR CET APPAREIL DOIT PROVENIR DE L EXT RIEUR NE PAS UTILISER CET APPAREIL AVEC LA TR MIE OUVERTE LE COUVERCLE DOIT TRE FERME ET BIEN VERROUILLE NE PAS UTILISER CET APPAREIL AVEC LA PORTE OUVERTE AVIS DE SECURITE LE NON RESPECT DE CES INSTRUCTIONS PEUT CAUSER DES DOMMAGES MAT RIELS DES BLESSURES OU M ME ENTRA NER LA MORT POUR VOTRE S CURIT ET VOTRE PROTECTION SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION CONTACTEZ LES AUTORIT S LOCALES EN MATIERE DE CONSTRUCTION OU LE SERVICE D INCENDIE AFIN DE CONNAITRE LES RESTRICTIONS ET LES EXIGENCES D INSPECTION DES INSTALLATIONS Y COMPRIS L OBTENTION DE PERMIS PROPRES VOTRE R GION Des questions Besoin de pi ces ou d options www heatredefined com WTERTE Pour un service en Francais Courriel R v 3 2015 infoenfrancais englanderstoves com Telephone 844 411 2654 ornoo Sens Lettre de notre service de soutien technique Merci d avoir achet cet excellent produit d England s Stove Works La famille qui a fond et poss de encore England s Stove Works croit fermement que les travaux que l on r alise soi m me sont les plus satisfaisants voil pourquoi vous avez trouv ce po le aupr s de votre m
100. in this manual It is important to note that if your vertical runs of pipe are more than fifteen feet 15 at this point the corn vent pipe should be increased to four inches 4 in diameter Do not exceed four feet 4 of pipe on a horizontal run and do attempt to use the least number of elbows in the flue system If an offset is used it is better to install a 45 degree elbow whenever possible Please remember installing elbows may inhibit your draft by up to 30 per elbow Outside Air Outside Combustion Air Intake Outside air is mandatory for this unit to operate properly This unit has been designed and tested with this connection because so many homes are airtight and there is not adequate combustion air available inside the dwelling The air intake pipe is located on the bottom side of the burnpot from the rear and measures 1 1 2 inside diameter I D The connection can be made with a metal 1 7 3 I D coupler and pipe see Important Information section of manual and should exit through the wall Be sure to secure the pipe to the unit with a clamp or aluminum tape The outside end of the pipe should be covered screened to prevent foreign matter from entering the system Our Outside Air Kit Part Number PU OAK can be used If the unit is located below ground level you will need to run the pipe up and then outside the dwelling NOTE If the total run of the connection exceeds six feet 6 if more than two elbows are used
101. ique au 1 800 245 6489 Les combustibles suivants ont t test s pour ce po le 1 Granules de bois de feuillus 2 Mais gren 3 Noyaux de cerise 5 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Le po le granules ma s et multicombustible a t test pour fonctionner avec du ma s dont le taux d humidit est inf rieur ou gal 14 96 il est recommand d utiliser du ma s dont le taux d humidit est de 11 12 pour optimiser le fonctionnement de l appareil Puisque le mais dont le taux d humidit est sup rieur 12 6 poss de un pouvoir calorifique moins lev il est difficile de provoquer sa combustion en utilisant les r glages en position faible Le mais doit tre propre et exempt de d bris n utilisez jamais de mais provenant directement du champ Une quantit excessive de particules fines de r sidus de la tige et de l pi etc peut boucher le m canisme de la vis granules Pour cribler votre mais nous
102. jacent building and not less than seven 7 feet above grade where located adjacent to public walkways The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people overheat combustible structures or enter buildings Forced draft systems and all parts of induced draft systems under positive pressure during operation shall be installed gastight or to prevent leakage of combustion products into a building Through the wall vents shall not terminate over public walkways or where condensate or vapor could create hazards or a nuisance Be sure to follow local codes and all manufacturer s instructions including exhaust pipe Consult a professional installer and or call Technical Support if you have any questions 7 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS NOTE YOUR UNIT MUST BE INSTALLED BY A QUALIFIED INSTALLER SUCH AS AN NFI CERTIFIED SPECIALIST GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER e A UL listed three inch or four inch 3 or 4 type L corn vent exhaust system must be used for installation and attached to the pipe con
103. l a flue damper of any kind in this system and do not connect this unit to a flue system serving another heating appliance Through the Wall To vent the unit through the wall connect the pipe adapter to the exhaust motor adapter If the exhaust adapter is at least eighteen inches 18 above ground level a straight section of corn pipe can be used to initially pass through the wall see Illustration 1 Your dealer or our factory should be able to provide you with a kit that will handle most of this installation which will include a wall thimble that will allow the proper clearances through a combustible wall Once outside the structure a three inch 3 clearance should be maintained to the outside wall and a clean out tee should be placed on the pipe that extends through the wall We recommend a minimum of three feet 3 of vertical pipe with a 90 degree turn away from the house At this point a one foot 1 section and horizontal cap will complete the installation see Illustration 1 A wall strap should be placed just below the last 90 degree section to make the system more stable If you live in an area that has heavy snowfall it is recommended the installation be taller than three feet 3 to get above the snowdrift line The same type installation can be used if your stove is below ground level by adding the clean out section and vertical pipe inside until ground level is reached However we recommend basement installation be perfor
104. l devrait tre teint et avoir refroidi avant l entretien pour la cendre Entretien bihebdomadaire pour la cendre REMARQUE L entretien pour le retrait de la cendre bihebdomadaire comprend les tapes de la pr sente section ainsi que les tapes des sections Entretien quotidien pour la cendre Deux fois chaque semaine Eteignez l appareil en appuyant sur la commande OFF et laissez l appareil terminer le cycle d arr t Attendez que l appareil ait compl tement refroidi puis retirez les cendres Les cendres devraient tre plac es dans un contenant incombustible avec un couvercle tanche l air et devraient toujours tre d pos es sur une surface incombustible ou sur le sol jusqu ce qu elles aient compl tement refroidi Une fois que la cendre est retir e le pot de combustion devrait tre inspect soigneusement Retirez et nettoyez le pot de combustion voir la page 15 V rifiez s il y a une accumulation l avant de la zone de br lage Nettoyez tous les trous d air qui devraient tre gard s propres puisqu ils fournissent l air comburant sous et autour du combustible Le support assembl dans lequel se trouve le pot de combustion devrait galement tre nettoy soigneusement IMPORTANT Une accumulation de cendres peut cr er une d faillance de l appareil Entretien mensuel pour la cendre REMARQUE L entretien mensuel pour le retrait de la cendre comprend les tapes de la pr sente section ainsi que les tape
105. le pot de combustion Rel chez le bouton une fois que le c t 4 dents de l agitateur pointe vers le haut vers l endroit o se trouve le 12 sur une horloge comme le montre l illustration 2 la page 14 Suivez ensuite les instructions pr c dentes relatives la facon de mettre une poign e de granules dans le pot de combustion et l allumage du feu section Allumer votre appareil manuellement la page 15 Passer des granules au mais Votre appareil est principalement concu pour la combustion de granules mais peut galement servir la combustion de mais Par d faut votre appareil est r gl pour la combustion de granules si vous souhaitez l utiliser pour la combustion de mais suivez les tapes ci dessous AVERTISSEMENT N ouvrez pas la porte de l appareil si l agitateur fonctionne toujours Consultez les instructions R glage de l agitateur la page 14 du pr sent guide REMARQUE Avant d effectuer ces tapes assurez vous que l appareil est teint et compl tement refroidi avant de le nettoyer 1 Vous devez r initialiser le panneau de commande pour br ler du mais D branchez l appareil puis rebranchez le Ensuite appuyez en m me temps sur les fl ches orient es vers le haut et le bas qui sont associ es la vitesse du ventilateur et rel chez les L cran associ la plage de chaleur devrait afficher les chiffres 1 8 Appuyez sur la fl che orient e vers le haut associ e la plag
106. lure to replace gaskets can cause air leaks resulting in smoke backs Remember that as with any appliance there is user responsibility involved including installation operation and maintenance of this product Be sure to check local codes and call Technical Support at 800 245 6489 if you have any auestions Be sure to follow the directions of all manufacturers of third party products that you use including exhaust pipe etc Never apply firestarter products including gel to a hot surface or hot coals Basement Installation Basement installation should be performed only by a professional installer For basement installations a three inch 3 pipe and coupler must be used for Outside Combustion Air and a minimum clearance of three feet 3 must be maintained from the ground to the corn vent exhaust pipe outside the dwelling Keep in mind that each elbow used reduces draft by up to 3096 it is good practice to add three feet 3 of vertical rise for each elbow used Example After the 2 elbow used add six feet 6 of vertical rise before terminating your vent pipe DANGER Do not open the door on this unit if the Stirrer is still moving See instructions on Setting the Stirrer later in this manual See burnpot installation pictures IMPORTANT NOTICE This unit must be properly installed to prevent the possibility of a house fire or smoke back The instructions must be strictly adhered to Do not use makeshift metho
107. m Protecteur de plancher n cessaire dimensions minimales de 91 44 cm x 121 92 cm Si la longueur totale du raccordement d air ext rieur d passe 1 82 m s il pr sente plus de deux coudes ou s il s agit d une installation en sous sol utilisez plut t un tuyau et un raccord m tallique de 3 po L air utilis par cet appareil doit provenir de l ext rieur afin d assurer un fonctionnement appropri et s curitaire PROTECTION DU SOL ET DES MURS Protection du plancher Si votre plancher est fabriqu avec un mat riau incombustible comme la brique ou le b ton aucun protecteur de plancher n est n cessaire Si le plancher est fabriqu avec un mat riau combustible comme le bois franc le linol um ou du tapis vous devez installer un protecteur de plancher entre l appareil et le mat riau combustible Le protecteur de plancher doit tre homologu UL ou l quivalent et doit tre suffisamment large pour couvrir une surface minimale de 15 24 cm l arri re et de chaque c t du po le Le d gagement minimal devant le po le doit tre d au moins 15 24 cm Cet appareil autoportant n cessite un protecteur de plancher d au moins 91 44 cm x 121 92 cm Protection des murs Un d gagement de seulement 15 24 cm est n cessaire entre l arri re du po le et le lambris le papier peint ou une cloison s che nous recommandons de pr voir un plus grand espace de d gagement afin de permettre l acc s pour l entretien Un d gagement de 15 24
108. med only by a professional installer For basement installations a 3 three inch pipe and coupler must be used for Outside Combustion Air and a minimum clearance of three feet 3 must be maintained outside the dwelling from the ground to the Corn Vent Exhaust Pipe Call 800 516 3636 to inquire about the AC 33000 Through the Wall Kit or Visit our web site at www heatredefined com for ordering information 11 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS The through the wall installation is the least expensive and simplest installation In a through the wall installation you should be mindful of the snowdrift line as well as dead grass and leaves We recommend a three foot 3 minimum vertical rise on the inside or the outside of the dwelling Through the Ceiling When venting the stove through the ceiling the pipe is connected the same as through the wall except the clean out tee is always on the inside of the house and a 3 adapter is added before the clean out tee You must use the proper ceiling support flanges and roof flashing supplied by the pipe manufacturer follow the pipe manufacturers directions and Illustration 1
109. nd to access the set screw 7 Locate the 32 Allen Head setscrew on the sprocket and loosen 8 Remove 5 locking collar from Stirrer shaft inside the unit using a 5 30 Allen Wrench 9 Remove shaft by pulling to you from outside the stove BR ND D 6 Motor mounting screws Illustration 5 Motor Shaft and Sprockets 23 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Gaskets IMPORTANT IMPROPER GASKET MAINTENANCE INCLUDING FAILURE TO REPLACE GASKETS CAN CAUSE AIR LEAKS RESULTING IN SMOKE BACKS This unit comes with a rope gasket around the door that should be replaced annually To replace the door gasket Part AC DGKCPM the old gasket must first be removed entirely prior to adding the new adhesive you may have to scrape the old cement from the door channel Once the cement and gasket have been added the door should be closed and latched for twenty four hours to allow the cement to harden If you are replacing the window gasket Part AC GGK the new gasket will already have adhesive on one side Remove the paper on the adhesive side and place the gasket around the outside edge of the glass centere
110. nector provided on the back of the unit Use a three inch to four inch 3 to 4 adapter for four inch 4 pipe A cap must be used at the termination of type L vent chimneys Four inch 4 type L is recommended for elevations above 2 500 feet above sea level e Do not terminate vent in any enclosed or semi enclosed area such as carports garage attic crawl space under a deck or porch walkway or enclosed area or any location that could build up a concentration of fumes such as a stairwell covered breezeway etc e Vent surfaces can get hot enough to cause burns if touched Non combustible shielding or guards may be required e Donotinstall a flue damper in the exhaust vent of this unit e Termination must exhaust above air inlet elevation Installation MUST include three 3 vertical feet of corn vent pipe This will create some natural draft to prevent the possibility of smoke or odor during unit shutdown and keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT DIRECTLY TO A MASONRY CHIMNEY e Distance from doors and windows gravity or ventilation air inlet into building not less than four feet 4 ft below four feet 4 ft horizontally from one foot 1 ft above this does not apply if the windows are non opening or have been fixed so they cannot open e Distance from bottom of termin
111. ng or replacing the blower a new gasket Part PU CBG should be added between the blower flange and the steel exhaust tube See the DVD video included with this unit for cleaning tips 21 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Soot and Fly ash Formation and Need for Removal The products of combustion will contain small particles of fly ash The fly ash will collect in the exhaust venting system and restrict the flow of flue gases Incomplete combustion such as occurs during startup shutdown or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary MAINTENANCE CAUTION UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK SEE EXPLODED DIAGRAM ILLUSTRATION 8 FOR PARTS REFERENCE Note To do any service on this unit the rear access sheet metal panel must be moved back from the stove to allow access One 1 screw holds this panel to the rear of the stove To remove the panel you must remove the cover plates on the exhaust and intake pipes 6 screws Auger Motor
112. nit is designed to burn multi fuel this feature will allow the unit to run and not hang up or lock up on a hard piece of corn etc It may make a jumping noise when you first start the unit but it will go away after your unit heats up It will not harm the unit It is a heavy duty system made with stainless steel designed to last many trouble free years FUEL NOT FEEDING CORRECTLY If the fuel is not feeding correctly the feed auger could possibly be misaligned due to factors such as rough handling during shipping If you suspect your feed auger is misaligned call Technical Support at 800 245 6489 Automatic Start Up When the ON button is pressed from a cold start the unit is in Start Up after 3 seconds there will be an S U in the Heat Range and Blower Speed windows to verify this While in this mode the unit has a preset heat range and will remain in this mode for 20 minutes 30 minutes in corn mode to prevent the unit from over firing During this start up period you can set the Control Board at the setting you desire after the start up is complete the unit will operate at the user setting Manually Starting Your Unit In the event the Auto Start does not initiate you may manually start your unit To manually start your unit first clean any pellets out of the burnpot to prevent over feeding Place a handful of new pellets in the burnpot then spread a small amount of pellet fire starter over the pellets and ignite them Af
113. nutes prior to opening the door A long handled screwdriver or long handled putty knife can be used to scrape off any build up or crust in the burnpot area Remove and clean the burnpot See page 15 Daily cleaning may not be required when burning wood pellets Ash Pan NOTE The ash pan must be locked in place when the unit is in operation NEVER operate the unit with the ash pan out or unsecured This unit has an ash pan for more convenient and hassle free cleaning to open lift up on the handle then pull the ash pan forward NOTE There are two handles just above the ash pan These control two access panels one on each side inside the unit in the bottom to put ashes into the ash pan Pull the handles toward you to open the panels push the ashes into the ash pan and then replace them making sure that the area under each plate is clear before closing it The unit should be off and cooled before any ash maintenance Semi Weekly Ash Maintenance NOTE The Semi Weekly Ash Removal maintenance should include the steps listed in this section as well as the steps listed in the Daily Ash Maintenance section Twice each week Shut the unit down by pressing the OFF pad and allowing the unit to go through the complete Shut Down cycle Allow the unit to completely cool down and then remove the ashes The ashes should be placed in a non combustible container with an airtight lid and should always be placed on a non combustible surface or on the groun
114. oint d tanch it de 12 7 mm autour de la porte qui doit tre remplac annuellement Pour remplacer le joint d tanch it de la porte num ro de pi ce AC DGKCPM retirez d abord le vieux joint en entier Avant d ajouter le nouvel adh sif vous devrez peut tre gratter la vieille colle du montant de porte Apr s avoir ajout de la colle et install le joint fermez et verrouillez la porte et laissez la ainsi pendant vingt quatre heures pour que la colle durcisse Si vous remplacez le joint de la fen tre num ro de pi ce AC GGK un des c t s du nouveau joint sera d j enduit de colle Retirez le papier du c t adh sif et placez le joint autour du bord ext rieur de la vitre centr sur le rebord Repliez les bords du joint d tanch it sur la vitre en formant un U Vous devriez galement remplacer le joint du ventilateur de combustion num ro de pi ce PU CBG chaque fois que vous retirez ou nettoyez le ventilateur de combustion De plus le joint du couvercle de la tr mie et le joint du bac cendres devraient tre inspect s et remplac s annuellement ou plus t t si n cessaire Fini Ce nouvel appareil a t peint avec de la peinture qui r siste aux temp ratures lev es et devrait conserver son aspect d origine pendant des ann es Si l appareil est mouill et que des taches de rouille apparaissent vous pouvez les poncer avec de la simple laine d acier et repeindre l appareil Nous recommandons l
115. on pour po le mais de Dura Vent notre num ro de pi ce AC 33000 M me si ce tuyau s emboite il est recommand de sceller tous les raccords l aide de silicone r sistant aux temp ratures lev es notre num ro de pi ce AC RTV3 ou de ruban conduits en aluminium Utilisez au moins trois vis pour fixer le tuyau au ventilateur d vacuation de l appareil Du plus si vous n utilisez pas un tuyau verrouillage par rotation pour po le mais homologu par UL assurez vous d utiliser un tuyau de ventilation pour po le mais homologu par UL et fixez chaque joint du tuyau l aide d au moins trois vis Le tuyau de type L ou le syst me de ventilation en acier inoxydable pour po le mais doit tre install de facon tre ETANCHE AUX GAZ Suivez les instructions pour l installation fournies par le fabricant du tuyau L endroit o le tuyau de ventilation traverse l ext rieur de la maison doit tre scell l aide de silicone ou par tout autre moyen afin d emp cher la vapeur de p n trer l int rieur de la maison D a REMARQUE Ces informations ne sont que des lignes directrices Pour obtenir une ventilation ad quate planifiez soigneusement l installation et usez de votre jugement Dans la plupart des installations un tuyau de ventilation de 3 po de diam tre est ad quat Si la ventilation n est pas ad quate vous devez le remplacer par un tuyau de 4 po de diam tre NE RACCORDEZ PAS L APPAREIL UN COND
116. onc jusqu ce que l agitateur pointe vers l endroit o se trouve le 12 sur une horloge le c t 4 dents point es vers le haut Retirez la goupille d attelage comme le montre l illustration 3 En soulevant le pot de combustion et l agitateur au m me moment retirez l agitateur du pot de combustion Nettoyez et d gagez tous les orifices du pot de combustion et remettez en place l agitateur et le pot de combustion dans l appareil REMARQUE Lorsque vous remettez le pot de combustion en place notez qu une fl che en acier soud est toujours orient e en direction de l arri re du foyer Assurez vous galement de remettre la goupille d attelage en place 16 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE PROC DURE DE CHANGEMENT DE COMBUSTIBLE Lorsque vous d marrez le po le pour br ler du ma s appuyez sur le bouton AIR ON TEMP temp rature de l air entrant et maintenez le enfonc ce qui fera tourner le m canisme de l agitateur dans
117. otre appareil manuellement 22 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Comme pour toute autre t che d entretien de ce produit assurez vous que l appareil est hors tension OFF et qu il soit compl tement arr t AVANT de proc der l entretien N oubliez pas que les pi ces m talliques du foyer peuvent rester CHAUDES longtemps apr s que les flammes se sont teintes et MEME longtemps apr s l arr t complet de l appareil Soyez toujours tr s prudent lorsque vous manipulez des pi ces du po le qui peuvent tre chaudes m me si vous pensez qu elles ont refroidi Remplacer le moteur d entrainement de l agitateur Localisez le panneau d acc s situ sur le c t droit du po le en regardant de l avant du po le Retirez les quatre 4 vis de montage de 5 16 po Localisez le support du moteur d entra nement retenu par deux 2 boulons C de po Desserrez ces boulons Localisez le boulon de r glage de la cha ne A de
118. our 4 46 mounting screws 3 Locate the drive motor mounting bracket which is secured by two 2 bolts C Loosen these bolts 4 Locate the chain adjustment bolt A on the left side of the drive motor Loosen this bolt 5 Remove the two 2 mounting bolts C 6 Slide drive motor mounting bracket toward the front of the stove and remove chain from sprocket B 7 Remove bracket and motor through access panel and disconnect the two power leads from motor Removing Motor and Sprocket Remove chain adjustment bolt A Locate the 3 Allen Head setscrew on the sprocket and loosen Remove sprocket B from motor shaft Remove the four 4 drive motor mounting screws D with a 5 6 nutdriver or socket ER ND NOTE When re installing the sprocket align the 3 Allen Head setscrew with the flat side of the motor shaft Replacing the Stirrer Drive Shaft Remove cast plug from right side looking from the front of the stove using a 46 Allen Wrench Locate the access panel on the right side looking from front of stove Remove the four 4 546 mounting screws D Locate the drive motor mounting bracket which is secured by two 2 bolts C Loosen these bolts 5 Locate the chain adjustment bolt A on the left side of the drive motor Loosen this bolt 6 Remove chain from Stirrer Shaft sprocket B NOTE It may be necessary to rotate the shaft by ha
119. oved from the unit periodically See Ash Removal section You can minimize cleaning required and maximize efficiency by maintaining the proper draft This unit has been designed to burn premium pellets dry shelled corn or dried cherry pits that meet the Pellet Fuels Institute PFI standards WOOD PELLETS Be consistent in your choice of wood pellet supplier Pellets will vary in content and burn characteristics from supplier to supplier e Check your pellets for foreign objects Your stove warranty will not cover any damage caused due to foreign objects in the fuel supply e Store your pellets in a dry place to prevent them from absorbing added moisture e To decrease sawdust buildup the hopper will need to be vacuumed out after every 6 8 bags of pellets or more often if the quality of the pellets is poor You may need to screen each bag of pellets if the sawdust becomes a problem e Wood pellets vary in size and also ash content from less than 196 to 396 or more Your unit will burn more efficiently with small to mid size pellets Low ash content pellets will allow you to burn the stove longer between cleanings e Your unit is designed to burn pellets that are no larger than one quarter inch 4 in diameter and no longer than two and one half inches 2 1 long CAUTION DO NOT PLACE SUCH FUELS WITHIN THE SPACE HEATER S INSTALLATION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR CLEANING AND ASH REMOVAL SHELLED CORN Dry pref
120. pas vous pouvez allumer votre appareil manuellement Pour allumer votre appareil manuellement retirez d abord toutes les granules du pot de combustion pour viter l engorgement Placez une poign e de nouvelles granules dans le pot de combustion puis r pandez une petite quantit d allume feu pour granules sur celles ci et allumez les Une fois les granules allum es fermez la porte de l appareil et appuyez sur le bouton ON marche si vous fermez la porte avant que les granules ne s allument compl tement le ventilateur d vacuation pourrait teindre le feu Les allume feu recommand s sont les suivants copeaux de bois impr gn s de cire cubes en carton ou copeaux allume feu con us pour les po les granules et mais Suivez les directives des fabricants de ces produits et ne d posez JAMAIS d allume feu sur une surface chaude ou sur des charbons chauds ATTENTION N utilisez jamais d essence de combustible pour lampe de k ros ne de liquide d allumage pour charbon de carburant diesel ni aucun autre liquide inflammable pour allumer un feu Gardez tout mat riau combustible une distance s curitaire du po le I est possible que l allumeur automatique ne permette pas d allumer du mais mouill Il peut tre utile de garder un sac de granules sous la main Si votre mais ne s allume pas teignez l appareil et nettoyez le pot de combustion en vous assurant que l appareil n est pas chaud Placez une tasse pleine de g
121. passing through combustible walls and ceilings Be sure to check local codes in your area NOTE See the installation drawing later in this manual Illustration 1 This unit is equipped with a negative draft system that pulls combustion air through the burnpot and pushes the exhaust air out of the dwelling If this unit is connected to the flue system other than the way explained in this manual it will not function properly For any of these installations keep in mind that each elbow used reduces draft by up to 3096 it is good practice to add three feet 3 of vertical rise for each elbow used Example After the 2 elbow used add six feet 6 of vertical rise before terminating your vent pipe Corn Vent Pipe The UL approved corn vent pipe that we recommend is a twist lock system however it is still recommended that high temperature silicone our Part Number AC RTV3 or aluminum duct seal tape be used at each joint England s Stove Works recommends the use of Dura Vent twist lock pipe if you use other pipe consult your local building codes and or building inspectors and secure each joint with at least three screws see Important Information section Do not use B vent gas pipe or galvanized pipe with this unit The corn pipe is designed to disassemble for cleaning and should be checked several times during the burning season corn vent pipe is not furnished with the unit and must be purchased separately Do not instal
122. per flue installation a blocked flue from rodents nests etc or dirty burning from burning improper fuel see Important Information at the beginning of the manual Igniter This unit has an auto start igniter Part CPM CH which starts by pushing the ON button on the control board If you use dry pellets or corn you should not have a problem with the igniter If you think the igniter is bad see page 14 Manually Starting Your Unit and call Technical Support Note Corn that is above 12 moisture content may not auto start You will need to manually start your unit 22 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS As with any maintenance concerning this unit be sure the unit is OFF and has completed the Shut Down cycle BEFORE beginning Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut Down cycle is complete Always use extreme caution when handling potentially hot stove parts even if you think they should be cold Replacing the Stirrer Drive Motor 1 Locate the access panel on the right side of stove looking from front of stove 2 Remove the f
123. pproximately three minutes or less the unit will resume operation when power is restored according to the following table Unit s State Before Power Loss State When Power Returns ON Start Up Start Up Start Up Shut Down Shut Down OFF OFF If the power is interrupted for more than approximately three minutes the unit will be OFF when power returns Important Do NOT open the hopper lid or the door to the unit during power outage Open the closest outside door and a window to eliminate the home s natural draft Wait for power to be restored and then press the ON button to re start the unit if desired Remember 1 Itis very important for the unit to be vented properly see instructions on Outside Air as the natural draft is needed to clear the smoke from the stove 2 Do not open the hopper lid or the unit s door This may cause fire to burn in the hopper Fuel Outage If your unit runs out of fuel let the unit go through the complete Shut Down cycle and then follow the instructions for restarting the unit NOTE DO NOT TRY TO RESTART THE UNIT HOT If the unit runs without pellets or corn after one hour the unit will shut down Combustion Blower Failure If the Combustion exhaust Blower should fail on this unit a Vacuum Shut Down Switch will automatically stop the auger This will cause your stove to stop feeding fuel to the burnpot and the unit will eventually stop completely Check your power suppl
124. r 4 Vacuum sensor 1 Auger not turning 2 Smoke smell or dust in 1 Improper exhaust house connection Tighten setscrew on collar Replace auger motor Remove pellets and object Check exhaust blower Check all connections for leaks especially the exhaust blower connection Seal with silicone hose clamp or aluminum tape operating 2 Bad blower Replace blower operating 2 Bad blower Replace blower Lazy fire Fire burns with a lazy orange flame and or fuel builds up in the burnpot Glass may become dirty Control board settings Bad exhaust blower Excessive pellet moisture Excessive ash Low quality pellets Flue or intake is restricted Glass door not shut and sealed tightly Ash removal plates are not pushed completely in Exhaust fan is not running or stove not venting properly Moisture content above 15 Blockage inside stove and exhaust pipes Feed rate is too high for fuel Inadequate combustion air available Power surge Exposed wire 6 Blown fuse 6 AMP Electric motor shorting or bound up 1 Review board settings 2 Replace blower 3 Keep pellets inside 4 Cleanunit 5 Use premium pellets 6 Inspect flue and intake for obstructions 7 Adjust door handle or replace gasket if necessary 8 Verify ash completely in 9 Verify that exhaust fan is running and venting properly If not check connection and clean or replace 10 Allow fuel to dry or mix with some wood pellet
125. r sultant d une ventilation ou d une installation inad quate Composez le 1 800 245 6489 ou consultez un installateur professionnel si vous avez des questions IMPORTANT Un raccordement inad quat trop de tuyaux trop de coudes etc peut emp cher l appareil de fonctionner Si vous avez des questions au sujet de votre raccordement ou si votre appareil ne fonctionne pas communiquez avec notre service de soutien technique 1 800 245 6489 CONSIGNES DE S CURIT IMPORTANTES Si l appareil ou le tuyau de raccord de chemin e rougit ou blanchit le po le est surchauff Cette situation pourrait causer un incendie ou un feu de chemin e Ne faites pas fonctionner votre appareil une temp rature trop lev e car il pourrait surchauffer 12 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Installation de l appareil autoportant granules ma s et multicombustible Attention Suivez les instructions du fabricant du tuyau pour l ins
126. r en savoir plus au sujet de l ensemble pour l installation travers le mur AC 3000 ou visitez notre site Web au ww w heatredefined com pour obtenir des renseignements sur les commandes 11 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE L installation travers le mur est la plus simple et la moins co teuse des installations Lorsque vous effectuez une installation travers le mur n oubliez pas de prendre en compte la hauteur du banc de neige ainsi que l herbe et les feuilles mortes Nous recommandons d installer une hauteur minimale de 0 91 m de tuyau l int rieur ou l ext rieur de l habitation travers le plafond Lorsque vous faites passer le tuyau de ventilation travers le plafond vous pouvez utiliser le m me raccordement qu travers le mur mais en installant le raccord d vacuation en T l int rieur de la maison et en ajoutant un adaptateur de 3 po avant le raccord en T Vous devez utiliser les supports de plafond
127. ranules de bois dans le pot de combustion d posez une petite quantit d allume feu parmi ceux recommand s ci dessus sur les granules de bois et allumez les Laissez les granules br ler pendant 1 ou 2 minutes puis fermez la porte et appuyez sur le bouton ON marche ATTENTION Le foyer doit tre froid au toucher avant de mettre l appareil en marche 15 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE REMARQUE Si l appareil ne d marre pas ou si le feu s teint le code E 2 s affichera sur les crans associ s la plage de chaleur et la vitesse du ventilateur sur le panneau de commande Dans un tel cas laissez l appareil refroidir compl tement et r p tez le processus Bague de blocage Goupille d attelage Goupille d attelage Illustration 4 Retirer l agitateur pour le nettoyage Une fois l appareil teint et compl tement REFROIDI appuyez sur le bouton AIR ON TEMP temp rature de l air entrant et maintenez le enf
128. re plus uniforme si vous utilisez des grains de petite taille ou de taille moyenne Si la taille des grains varie largement ou si vous changez souvent de fournisseur vous obtiendrez une combustion moins uniforme N utilisez pas de mais forte teneur en cire Passez l aspirateur dans la tr mie apr s avoir utilis 6 8 sacs afin d liminer les d p ts de sciure et de particules fines de mais Votre appareil est principalement congu pour la combustion de granules mais peut galement servir la combustion de noyaux de cerise s ch s Assurez vous que votre fournisseur vend des noyaux de cerise s ch s pr f rablement des noyaux dont le taux d humidit est inf rieur 4 96 destin s servir de combustible pour les po les granules IMPORTANT N UTILISEZ PAS DE NOYAUX DE CERISE CONCUS POUR LES ACTIVITES ARTISANALES OU RECREATIVES Les noyaux de ce genre sont habituellement blanchis ou trop dess ch s 6 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL A EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PIECES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUT
129. re qualit car ce po le est concu pour les granules de premiere qualit Les granules contenant une grande quantit de cendres causent une combustion sale qui n cessite un entretien plus fr quent Si vous choisissez le chauffage au mais vous devez utiliser du mais dont le taux d humidit est inf rieur 14 96 Le mais dont le taux d humidit est lev cause une combustion sale qui n cessite un entretien plus fr quent Si vous choisissez le chauffage aux noyaux de cerise vous devez utiliser des noyaux de cerise dont le taux d humidit est inf rieur 4 Les noyaux de cerise dont le taux d humidit est lev causent une combustion sale qui n cessite un entretien plus fr quent Assurez vous que votre mais vos noyaux de cerises ou vos granules ne sont pas mouill s ou humides Si le combustible est trop humide votre po le ne pourra pas fonctionner basse temp rature le feu s teindra Assurez vous que l appareil est exempt de sciure de bois de d bris et de particules fines Lors de l installation de ce po le utilisez un TUYAU DE VENTILATION VERROUILLAGE PAR ROTATION POUR PO LE MAIS homologu par UL de 3 po et suivez les indications du fabricant concernant l installation et les distances respecter nous recommandons fortement le tuyau verrouillage par rotation pour po le mais de Dura Vent notre num ro de pi ce AC 33000 M me si ce tuyau s embofte il est recommand de sceller tous les raccord
130. redefined com for helpful information frequently asked questions parts accessory orders and more IMPORTANT INFORMATION READ BEFORE OPERATING When installing your Pellet Corn Multi fuel stove particular attention needs to be made in regards to fire protection If the unit is not properly installed a house fire may result For your safety follow the installation and operation instructions provided and if a question arises contact local building or fire officials about restrictions and installation requirements in your area e Read the Operation and Fuel sections of this manual before plugging in your unit e Always unplug the unit before attempting any service work e Do not connect the unit to a chimney flue already serving another appliance e When installing the chimney pipe to the unit it is important to remember that the unit operates on negative pressure and the chimney on positive pressure All chimney connections elbows and fittings must be air tight Proper venting practices must be followed Consult with a venting professional e Ashes must be disposed of in a metal container with a tight fitting lid e All minimum clearances to combustibles must be followed e It is important to use fuel that is clean dry and consistent It is recommended that you purchase your entire heating season supply of fuel at one time to make sure it is the same e This unit has been tested with 3 different fuels as of May 2007 Call
131. rizontale ne doit pas d passer 1 21 m et le conduit de fum e ne doit pas d passer une hauteur de 10 66 m A partir d une hauteur de 4 57 m vous devez passer un tuyau de ventilation pour po le mais de 4 po Vous devez teindre l appareil et le laisser refroidir avant de le nettoyer Placez les cendres dans un contenant m tallique herm tique et attendez qu elles soient compl tement refroidies avant de les jeter Lisez attentivement les instructions y compris les instructions concernant le panneau de commande num rique et conservez les pour vous y r f rer ult rieurement Ne laissez pas de la peinture des produits chimiques ou des poussi res de travaux de construction se d poser sur l appareil ou pr s de celui ci Gardez l ext rieur et l int rieur de votre appareil l abri des liquides et de TOUT corps tranger Eteignez votre appareil et couvrez le pendant les travaux de peinture de construction ou d autres activit s de ce type Essuyez et nettoyez l appareil une fois les travaux de construction de votre maison termin s ou si un corps tranger se retrouve l ext rieur ou l int rieur de l appareil Il peut s av rer n cessaire de retirer les couvercles lat raux et le couvercle arri re de l appareil d branchez le d abord afin de nettoyer les moteurs et l int rieur de l appareil et d y passer l aspirateur L entretien inad quat des joints y compris le d faut de remplacement des joints peut se traduire par
132. rsque la temp rature de fonctionnement descend sous les 32 2 C Il continuera le faire par intermittence au rythme tabli par le r glage de la chaleur jusqu l arr t Vis granules Au d marrage la vis granules se mettra tourner La vis granules continuera d alimenter le po le au rythme tabli par le r glage de la chaleur REMARQUE L interrupteur de s curit le capteur de limite de haute temp rature et de l aspirateur doivent tre activ s pour un fonctionnement continu ad quat Ventilateur ambiant Convection Se met en marche lorsqu une temp rature de 43 3 C est atteinte Il continuera de fonctionner jusqu ce que l appareil se refroidisse et atteigne une temp rature sous les 32 2 C Cela peut prendre de quelques minutes une heure Arr t automatique Si apr s 15 minutes l appareil n a pas atteint la temp rature de fonctionnement pr s lectionn e l appareil commencera automatiquement la mise hors tension Cela sera signal par la lumi re rouge sur le panneau de commande Si la minuterie arrive terme avant que la temp rature de fonctionnement pr s lectionn e ne soit atteinte il est possible de la red marrer en arr tant l appareil puis en le remettant en marche sur le panneau de commande Fonctionnement normal Si apr s 15 minutes la temp rature de fonctionnement pr s lectionn e de 43 3 C est atteinte le fonctionnement normal se
133. rt Department Technical Support Department service englanderstoves com P O Box 206 Parts Orders ONLY 800 516 3636 Monroe VA 24574 Questions 800 245 6489 Fax 434 929 4810 27 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS REPLACEMENT PARTS ITEM PART NUMBER PART DESCRIPTION 1 CA 10 Door 2 AC G20 Glass with Gasket H 11 5 X W 14 75 3 AC GGK Glass Gasket Kit 4 AC GSCPM Glass Supports 5 CA 11 Side Panel Castings 6 CA DH Cast Door Handle 7 CPM CFB Brick Fiber board 8 CPM BP Burnpot 9 CPM FS Fuel Stirrer 10 CPM MC Fuel Stirrer Collar s 11 CA CPMDS Fuel Stirrer Drive Shaft 12 R FN HP Fuel Stirrer Hitch Pin 13 CPM FST Fuel Stirrer Tube 3 14 R FN SF 2024 16 Fuel Stirrer Bushings 1 2 each 15 CPM 26CH Fuel Stirrer Drive Chain 16 CPM SP Fuel Stirrer Sprocket 2 each 17 CPM SMB Stirrer Motor Bracket 18 PU AFUF Auger 19 CPM RCP Right Side Cover Plate 20 PU 047040 1 RPM Stirrer Motor 21 CPM CB07 Control Board 22 CPM CB07A Aux Corn Control Board 23 CU VS Vacuum Switch 24 PU VH Vacuum Hose 25 AC APCPM Ash Pan 26 AC 03 Ash Pan Knob 27 CPM BR LorE Base amp Riser 28 PU CBG Exhaust Blower Gasket 29 PU 076002S CPM Exhaust Blower
134. s granules est fix e son moteur par un coupleur qui est fix au moteur de la vis granules par une vis de calage Si le coupleur est l che retirez le moteur de la vis granules et resserrez la vis de calage dans le coupleur Le couvercle est entrouvert ou ouvert il y a des d bris sous le joint d tanch it de la tr mie Cela est vident lorsque l appareil est extr mement chaud R duisez la plage de chaleur de 1 V rifiez le ventilateur nettoyez le ou remplacez le au besoin Nettoyez n importe quelle obstruction de la ventilation Trop de coudes dans la ventilation limitent le flux d air ce qui provoque le d clenchement d un interrupteur d aspirateur Inspectez la connexion et remplacez la au besoin Une installation inad quate peut cr er un refoulement d air REMARQUE V rifiez galement si le boyau de l aspirateur est l che ou fissur sur les interrupteurs du ventilateur voir le sch ma des pi ces REMARQUE Une pression n gative dans un logement est un probl me s rieux Cet appareil doit tre install avec l ensemble de raccords l air ext rieur num ro de pi ce PU OAK ATTENTION D BRANCHEZ L APPAREIL AVANT N IMPORTE QUEL ENTRETIEN 33 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS
135. s 11 Check inside stove and exhaust pipes for blockage Tap inside walls of Firebox clean behind the lower access plates located on the back inside wall next to the burnpot clean burnpot and Firebox vent holes above firebrick panel Reduce heat setting removal plates are pushed Outside combustion air is mandatory Our Part PU OAK is acceptable 1 Replace fuse use surge protector 2 Check for exposed or frayed wire and loose connections 3 Check motors and blowers for obstructions or lock up 2 Board out of adjustment Check control board settings 2 Blower noise S Remove and oil blower 1 Foreign material Loose set screw 9 Pinging or rattling noise 2 1 Check blower for material 2 Check impeller blower screw Improper installation may cause a back draft NOTE Also check for loose or cracked vacuum hose on vacuum switches see Parts Diagram NOTE Negative pressure in a home is a serious issue This unit must be installed with the Outside Air Kit Part PU OAK CAUTION UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK 31 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS TROUBLE SHOOTING GUIDE WARNING
136. s l aide de silicone r sistant aux temp ratures lev es notre num ro de pi ce AC RTV3 ou de ruban conduits en aluminium Utilisez au moins trois vis pour fixer le tuyau au ventilateur d vacuation de l appareil Du plus si vous n utilisez pas un tuyau verrouillage par rotation pour po le mais homologu par UL assurez vous d utiliser un tuyau de ventilation pour po le mais homologu par UL et fixez chaque joint du tuyau l aide d au moins trois vis L air de combustion utilis par ces appareils doit provenir de l ext rieur afin d assurer leur bon fonctionnement Pour effectuer ce raccordement utilisez un tuyau et un raccord m talliques en acier en aluminium ou en cuivre dot s d un diam tre int rieur de 1 7 4 po Assurez vous de fixer le tuyau l appareil l aide d un collier ou de ruban en aluminium Vous devez couvrir l aide d un grillage l extr mit ext rieure pour emp cher tout corps tranger d entrer dans le syst me Assurez vous que le tuyau comporte le moins de coudes possible Pour ce faire vous pouvez utiliser notre num ro de pi ce PU OAK ensemble de raccord l air ext rieur avec tuyau flexible REMARQUE Si la longueur totale du raccordement d passe 6 pi utilisez plut t un tuyau et un raccord m talliques de 3 po Inspectez r guli rement le pot de combustion retirez le pot d alimentation et nettoyez tous les orifices bouch s Consultez la section Entretien En fon
137. s ajustera automatiquement en fonction de la plage de chaleur que vous s lectionnerez PLAGE DE VITESSE DU CHALEUR VENTILATEUR VOYANT D AFFICHAGE DEL VOYANT D AFFICHAGE DEL Ventilateur d air ambiant C PM De 1 FAIBLE 9 LEV E Affichage du rythme de l alimentation R glage pour augmenter le rythme de l alimentation R glage pour augmenter le CPM du ventilateur R glage pour diminuer le rythme ATTENTION REMARQUE Les trois boutons inf rieurs ont t pr r gl s en usine et ne n cessitent pas de r glages suppl mentaires amp Si vous avez des questions AIR DE ou des probl mes on ep TEMP AIR communiquez avec notre FAIBLE FABLE ENTRANT Service de soutien technique au 1 800 245 6489 R glage pour diminuer le CPM du ventilateur Illustration 6 Sch ma du panneau de commande ATTENTION Les pi ces mobiles peuvent causer des blessures N utilisez PAS l appareil si des panneaux ne sont pas en place DANGER Les pi ces peuvent tre chaudes Risque de choc lectrique Coupez l alimentation avant d effectuer l entretien de l appareil 25 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN
138. s assurer qu il est suffisamment sec IMPORTANT NE FAITES PAS BR LER DE MA S DE SEMENCE TRAIT DANS VOTRE PO LE Le mais de semence est trait avec des pesticides chimiques dont l ingestion peut tre nocive ou fatale Par cons quent il est dangereux d avoir du mais de semence la maison surtout dans un endroit accessible aux enfants La combustion de mais de semence trait entrainerait l annulation de la garantie et d truirait le syst me d vacuation de l appareil NOYAUX DE CERISE S ch s pr f rablement avec un taux d humidit inf rieur 4 96 Votre appareil est principalement concu pour la combustion de granules mais peut galement servir la combustion de noyaux de cerise s ch s Assurez vous que votre fournisseur vend des noyaux de cerise s ch s destin s servir de combustible pour les po les granules IMPORTANT N utilisez PAS de noyaux de cerise con us pour les activit s artisanales ou r cr atives Les noyaux de ce genre sont habituellement d color s ou trop dess ch s 10 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTAL
139. s des sections Entretien quotidien pour la cendre et Entretien bihebdomadaire pour la cendre Utilisez un tournevis ou un ciseau et brisez les accumulations de cr osote sur le devant de l appareil l endroit o le pot de combustion est aliment en granules par le tube de la vis granules Inspectez galement les conduits de fum e et enlevez l accumulation de cendres du raccord en T Entretien annuel REMARQUE L entretien annuel pour le retrait de la cendre comprend les tapes de la pr sente section ainsi que les tapes des sections Entretien mensuel pour la cendre Entretien quotidien pour la cendre et Entretien bihebdomadaire pour la cendre Le po le et le syst me de conduit de fum e devraient tre nettoy s compl tement la fin de la p riode de chauffage Retirez le pot de combustion voir la page 15 nettoyez le soigneusement et r installez le En plus du nettoyage bihebdomadaire et mensuel mentionn le ventilateur d vacuation de combustion devrait tre retir annuellement et un aspirateur devrait tre pass dans le tube d vacuation pour enlever toute accumulation de cendres Ajoutez un nouveau joint num ro de pi ce PU CBG entre le rebord du ventilateur et le tube d vacuation en acier lorsque vous nettoyez ou remplacez le ventilateur Regardez la vid o sur le DVD compris avec cet appareil pour des conseils de nettoyage 21 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L
140. s publics adjacents Il faut installer la sortie d vacuation afin que les gaz ne soient pas dirig s de mani re d ranger les gens ne surchauffent pas de structures combustibles ou n entrent pas dans des b timents Il faut installer les syst mes tirage forc et toutes les pi ces des syst mes tirage induit sous pression positive pendant le fonctionnement pour qu ils soient tanches aux gaz ET pour emp cher la fuite de produits de combustion vers l int rieur d un b timent Les conduits travers le mur ne doivent pas se terminer au dessus de trottoirs publics o l o le condensat ou la vapeur pourraient cr er des risques ou une nuisance Veiller suivre les codes locaux et toutes les directives du fabricant y compris celles du tuyau d vacuation Consultez un installateur professionnel ou appelez le support technique si vous avez des questions 7 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE REMARQUE VOTRE APPAREIL DOIT TR
141. site and call our Technical Support department at 800 245 6489 if you need any help with your unit We are nearly always able to help walk you through any repairs problems or questions you may have PLEASE NOTE While information obtained on our web site and through our 800 number is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we may arrange Wishing you years of efficient quality and comfy heating England s Stove Works Technical Support Department www heatredefined com 800 245 6489 IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER CONTACT TECHNICAL SUPPORT at 1 800 245 6489 2 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS IMPORTANT INFORMATION 1 Installation of this Pellet Corn Multi fuel unit should be performed by a professional only Check local installation codes for your area Call your Homeowners Insurance representative for inspection of your stove s installation 2 Read and comply with the instructions in this manual 3 This unit should be tested dry run for 20 minutes before loading pellets or cherry pits Th
142. stment for Decreas e Fuel Feed De crease Blow er CFM CAUTION NOTE The bottom 3 buttons are pre set at the factory and do not need adjustment Call Technical Support at 800 245 6489 if you have questions or Illustration 6 problems Control Board Diagram CAUTION Moving Parts May Cause Injury Do NOT Operate with Panel s Off DANGER Parts May Be Hot Risk of Electric Shock Disconnect Power Before Servicing Unit 25 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS Illustration 7 Control Board Diagram Wiring HIGH TEMP CPM CBO07 CPM 07A CONTROL BOARDS VAC HOSE TO THE IGNITOR CAUTION 120 VOLT EXPOSED ON THIS CIRCUIT DISCONNECT FROM THE POWER SOURCE MOVING HOT PARTS MAY CAUSE INJURY HIGH TEMP DO NOT OPERATE WITH PANEL REMOVED VAC HOSE THE THERMAL SENSOR IS NOT A GROUND TO AIR PUMP AIR PUMP TO ee THE IGNITOR IGNITER COMBUSTION VACUUM SWITCH BLOWER HIGH TEMP VAC HOSE TO LEFT SIDE OF FIRE STIRRER MOTOR 1RPM GREEN GROUND FEED MOTOR 2 4 RPM 120 VOLT HOPPER LID SAFETY SWITCH LINE ROOM AIR BLOWER CIRCUIT BOARD FUNCTIONS
143. t 45 minutes before trying to re light the unit If you have any questions or problems contact the Technical Support Department Technical Support Department service englanderstoves com P O Box 206 Parts Orders ONLY 800 516 3636 Monroe VA 24574 Questions 800 245 6489 Fax 434 929 4810 You may also order parts and options view frequently asked questions and more on our Web Site www heatredefined com 19 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS DAILY OPERATION Refueling the Unit Always press the OFF touch pad before refueling The hopper on this stove holds approximately 50 Ibs wood pellets and should be refilled when the fuel level drops to three or four inches Note The hopper lid will be warm therefore you should always use some type of hand protection NEVER place your hand near the auger while the stove is operating Note Always ensure that all corn and pellet matter is cleared from the hopper lid gasket before closing Be sure to close and latch hopper securely before re firing Do not operate this unit with the hopper lid open or unsecured Power Outage If the power to the unit is interrupted for a
144. t allow the exclusion or limitations of incidental or consequential damages so the above may not apply to you Procedure Purchaser must give notice of claim of defect within the warranty period and pay transportation to and from a service center designated by the factory The dealer from which the unit was purchased or the factory at our option will perform the warranty service Other Rights This warranty gives you specific legal rights and you may also have other rights which may vary from state to state NOTE THIS WARRANTY IS NULL AND VOID IF YOU DO NOT RETURN THE ATTACHED WARRANTY REGISTRATION WITH A COPY OF THE SALES RECEIPT WITHIN 30 DAYS FROM THE DATE OF PURCHASE WARRANTY IS NOT TRANSFERABLE 34 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS WARRANTY REGISTRATION for England s Stove Works Purchased by Name Address City State Zip Telephone Email Address DEALER INFORMATION Purchased From Dealer Address City State Zip UNIT INFORMATION Please be sure to refer to label on stove or sale receipt to complete this section Model Number Purchase Date Purchase Price
145. t burning stoves Do not use cherry pits designed for crafts or hobbies as this type is usually bleached or over dried Your unit comes ready to burn pellets by default if you would like to burn cherry pits in your unit follow the steps below WARNING Do not open the door on this unit if the Stirrer is still moving See instructions Setting the Stirrer on page 13 in this manual NOTE Before performing these steps make sure the unit is out and completely cold 1 Remove the Stirrer shaft See Illustrations 3 amp 4 Page 15 Do not use the Stirrer when burning cherry pits 2 The control board must be reset to burn cherry pits Unplug the unit and plug back in then press the Blower Speed up and down buttons at the same time and release Push the Heat Range up arrow until you see a 6 Wait for the window to clear Remember to remove the Stirrer page 15 Set Air On button to 0 see page 14 first paragraph You are now set to burn cherry pits To change the stove back to burn corn Push the Heat Range down arrow until you see a 5 Wait for the window to clear You are now set to burn corn To change the stove back to burn pellets Push the Heat Range down arrow until you see a 1 Wait for the window to clear You are now set to burn pellets Remember to replace the stirrer and set it to run when burning pellets and corn see Setting the Stirrer page 13 3 Follow lighting instructions 17 IMPORTANT READ AND F
146. t offert Visitez le site www heatredefined com si vous pr f rez vous enregistrer en ligne 36 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE
147. tallation et les instructions pour le faire passer travers un mur ou un plafond combustible Consultez les codes locaux de votre r gion Illustration 1 eq Il est acceptable n d utiliser notre num ro E de pi ce AC 33000 pour effectuer une installation travers le mur Pour les installations une altitude de plus de 762 m nous recommandons d utiliser un tuyau de 4 po notre num ro de pi ce AC 33100 Pour les installations plus longues vous devez utiliser un adaptateur de 3 po avant le raccord en T Pour les installations plus courtes l utilisation d un raccord en T seulement est acceptable L installation en sous sol doit D gagement de 0 91 m tre effectu e par un Installation installateur professionnel en X Utilisez un tuyau et un raccord m talliques de 3 po pour l admission d air de combustion ext rieur Un Tuyau de oo d gagement minimal de raccord l air 0 91 m est n cessaire entre ext rieur de 3 po le sol et le tuyau de ventilation pour po le ma s L air utilis par cet Pal DOIT PROVENIR DE EXT RIEUR afin d assurer son bbn t fonctionnement T Si la longueur du conduit de fum e de 3 po est sup rieure 4 57 m utilisez un conduit de fum e de 4 po pour les conduits restants La longueur totale du conduit de fum e ne doit pas d passer 10 66 m La longueur horizontale ne doit pas d passer 1 21
148. ter the pellets ignite close the door to your unit and press the ON button if the door is closed before the pellets fully ignite the Exhaust Blower could put out the fire Recommended fire starter materials are Wax impregnated wood chips cardboard cubes or firestarter chips designed for pellet and corn burning stoves Follow any manufacturer s directions for these products and NEVER place any firestarter on any hot surface or hot coals CAUTION Never use gasoline lantern fuel kerosene charcoal lighter fluid diesel fuel or any other flammable liquid to start the fire Keep all combustible materials at a safe distance from stove Wet corn may not start with your auto start igniter It will help to keep a bag of pellets handy If your corn does not ignite shut the unit down clean out the burnpot and make sure the unit is not warm Place a cup full of wood pellets in the in the burnpot place a small amount of one of the recommended fire starters listed above on the wood pellets and ignite the pellets Allow the pellets to burn for 1 2 minutes then close the door and push the ON button CAUTION The Firebox should be cool to the touch before attempting to start the unit 15 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT
149. u de V rifiez les r glages d marrez toujours l appareil 3 chec du d marrage V rifiez s il y a des accumulations dans l allumeur Une installation inad quate peut cr er un refoulement d air REMARQUE V rifiez galement si le boyau de l aspirateur est l che ou fissur sur les interrupteurs du ventilateur voir le sch ma des pi ces REMARQUE Une pression n gative dans un logement est un probl me s rieux Cet appareil doit tre install avec l ensemble de raccords l air ext rieur num ro de pi ce PU OAK ATTENTION D BRANCHEZ L APPAREIL AVANT N IMPORTE QUEL ENTRETIEN 32 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE GUIDE DE D PANNAGE AVERTISSEMENT POUR VITER LES CHOCS LECTRIQUES DEBRANCHEZ TOUJOURS L APPAREIL DE L ALIMENTATION AVANT D EFFECTUER N IMPORTE QUELLE R PARATION SI VOUS NE TROUVEZ PAS DE SOLUTION VOTRE PROBL ME DANS LE PR SENT GUIDE COMMUNIQUEZ AVEC VOTRE REVENDEUR OU AVEC NOTRE SERVICE DE
150. uctions sur l air ext rieur puisque le tirage naturel est n cessaire pour faire sortir toute la fum e du po le 20 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE INSTALLATION OU D UNE UTILISATION DANGEREUSE DE CE PRODUIT POUR TOUTE QUESTION COMMUNIQUEZ AVEC LE SERVICE DE SOUTIEN TECHNIQUE Comme pour toute autre t che d entretien de ce produit assurez vous que l appareil est hors tension OFF et qu il soit compl tement arr t AVANT de proc der l entretien N oubliez pas que les pi ces m talliques du foyer peuvent rester CHAUDES longtemps apr s que les flammes se sont teintes et M ME longtemps apr s l arr t complet de l appareil Soyez toujours tr s prudent lorsque vous manipulez des pi ces du po le qui peuvent tre chaudes m me si vous pensez qu elles ont refroidi RETRAIT ET LIMINATION DES CENDRES IMPORTANT Bien que la quantit de cendres produite par cet appareil ne soit pas tr s grande par rapport celle des po les bois traditionnels il est essentiel que vous gardiez l appareil propre et exempt de cendres pour maintenir un rendement
151. une fois le loquet serr testez la tension du loquet en verrouillant le couvercle vers le bas et en soulevant les coins avant Le couvercle doit tre fermement retenu par le loquet R p tez les m mes tapes si le loquet n est toujours pas assez serr Important Le loquet du couvercle de la tr mie doit tre v rifi Ensemble du loquet Q p riodiquement et maintenu serr de sorte que la partie sup rieure soit scell e et emp che un retour de feu Assemblage du loquet du couvercle de la tr mie ZONE DE RACCORD PAISSEUR MAX PANNEAU EXT 6 0 25 js CLIQUET VERS L AVANT 60 2 4 BR filetage we Le 3 0 12 RELEVER AGRAFE DE BUT E DU CLIQUET FREIN D CROU NE PAS TOUCHER CET CROU REGLE EN USINE ENSEMBLE VIS FREIN D CROU Filetage M5 Les panneaux d une paisseur de plus de 6 mm 0 25 po n cessitent une combinaison vis rondelle de blocage plus longue non fournie L FERRURE DE MONTAGE 4 0 16 be TARAUD E Les 40 1 58 56 2 20 30 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOI
152. ur les dommages cons cutifs en cas de violation de toute garantie crite ou implicite Certains Etats ou certaines provinces ne permettent pas l exclusion ou la limitation des dommages accessoires ou cons cutifs de sorte que les exclusions mentionn es ci dessus peuvent ne pas s appliquer vous Proc dure L acheteur doit soumettre une r clamation de d faut pendant la p riode de garantie et payer le transport vers un centre de service et partir d un centre de service d sign par le fabricant Le revendeur qui a vendu l appareil ou le fabricant notre gr effectuera la r paration sous garantie Autres droits Cette garantie vous conf re des droits pr cis Il est possible que vous disposiez galement d autres droits qui varient d un Etat ou d une province l autre REMARQUE CETTE GARANTIE EST NULLE ET NON AVENUE SI L ACHETEUR N ENVOIE PAS LA CARTE D ENREGISTREMENT DE LA GARANTIE CI JOINTE ET UNE COPIE DU RECU DE VENTE DANS LES 30 JOURS A COMPTER DE LA DATE D ACHAT CETTE GARANTIE EST NON TRANSF RABLE 35 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGENCE OU CAUSE D UNE I
153. urel de la maison Attendez que l alimentation lectrique soit r tablie puis appuyez sur le bouton ON pour remettre l appareil en marche si d sir Rappel 1 Il est tr s important que l appareil soit correctement ventil consultez les instructions sur l air ext rieur puisque le tirage naturel est n cessaire pour faire sortir toute la fum e du po le 2 N ouvrez pas le couvercle de la tr mie ou la porte de l appareil Cela peut faire en sorte que le feu br le dans la tr mie Manque de combustible Si votre appareil manque de combustible laissez le terminer le cycle d arr t et suivez ensuite les instructions pour remettre l appareil en marche REMARQUE NE TENTEZ PAS DE REMETTRE L APPAREIL EN MARCHE LORSQU IL EST CHAUD Si l appareil fonctionne sans granules ou sans mais il s arr tera apr s une heure Panne du ventilateur de combustion Si le ventilateur d vacuation de combustion de cet appareil tombait en panne un interrupteur d arr t de l aspirateur arr terait la vis granules Cela fera en sorte que votre po le n alimentera plus le pot de combustion et l appareil finira par s arr ter compl tement V rifiez votre source d alimentation y compris pour v rifier si un disjoncteur s est d clench etc Si le ventilateur est en panne vous devrez communiquer avec le Service de soutien technique au 1 800 245 6489 REMARQUE II est tr s important que l appareil soit correctement ventil consultez les instr
154. utilisation de la peinture en a rosol r sistant aux temp ratures lev es num ro de pi ce AC MBSP car les autres types de peinture pourraient ne pas adh rer la surface ou ne pas supporter les temp ratures lev es Vitre Cet appareil poss de une vitre en vitroc ramique num ro de pi ce AC G20 fournie avec un joint dans la porte vitr e Les rayures de surface sont acceptables mais si n importe quelle partie de cette vitre se fissure arr tez l appareil et remplacez la fen tre par une vitre en vitroc ramique r sistant aux temp ratures lev es Si vous avez des questions ou des probl mes communiquez avec le Service de soutien technique Technical Support Department service englanderstoves com P O Box 206 Commandes de pi ces SEULEMENT 1 800 516 3636 Monroe VA 24574 Etats Unis Questions composez le 1 800 245 6489 T l copieur 1 434 929 4810 Vous pouvez galement commander des pi ces et des accessoires consultez la foire aux questions et encore plus sur notre site Web www heatredefined com 24 IMPORTANT LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN NOTAMMENT CELLES PORTANT SUR LE NETTOYAGE DE L APPAREIL EFFECTUER SELON LES DIRECTIVES ET CELLES PORTANT SUR LE REMPLACEMENT DES JOINTS ANNUELLEMENT ET DES PI CES AU BESOIN ENGLAND S STOVE WORKS N EST PAS RESPONSABLE DES DOMMAGES NI DES BLESSURES QUELS QU ILS SOIENT SUBIS EN RAISON DE N GLIGEN
155. ventilateur 10 L appareil s arr te apres D tecteur de chaleur l che V rifiez les connexions du po le fonctionnement et le panneau de commande affiche le code E 2 11 L appareil s teint 1 Leconduit de fum e est V rifiez si le conduit de fum e est obstru constamment bloqu E 2 nids rongeurs accumulations de suie etc 2 L appareil a surchauff E 3 Si le code E 3 appara t sur votre panneau de Affichage de codes E sur commande votre appareil a surchauff Vous devez le panneau de commande laisser l appareil refroidir et nettoyer le foyer et le pot de combustion Assurez vous de nettoyer les orifices trous dans le pot de combustion Vous ne devriez pas faire fonctionner votre appareil une temp rature lev e continuellement plage de chaleur 9 lorsque vous utilisez du ma s comme combustible Apr s avoir fait br ler du mais pendant quelques heures une temp rature lev e baissez la plage de chaleur 7 et augmentez la vitesse du ventilateur 9 Faire fonctionner l appareil une temp rature lev e lorsque vous br lez du mais pour une p riode prolong e peut endommager l appareil 3 Installation inad quate E 2 V rifiez si les connexions des conduits de fum e ou des tuyaux sont l ches Assurez vous galement d avoir un raccordement d air ext rieur appropri commande avec un r glage allant de 5 9 1 20 30 minutes de 2 R glages du pannea
156. y including tripped breakers etc If the blower has failed you will need to contact Technical Support at 800 245 6489 NOTE It is very important for the unit to be vented properly see instructions on Outside Air as the natural draft is needed to clear the smoke from the stove 20 IMPORTANT READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS INCLUDING CLEANING THE UNIT AS SPECIFIED AND REPLACING GASKETS ANNUALLY AND PARTS AS NEEDED ENGLAND S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT CALL TECHNICAL SUPPORT WITH QUESTIONS As with any maintenance concerning this unit be sure the unit is OFF and has completed the Shut Down cycle BEFORE beginning Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut Down cycle is complete Always use extreme caution when handling potentially hot stove parts even if you think they should be cold ASH REMOVAL AND DISPOSAL IMPORTANT While the amount of ash generated by this unit is not excessive compared to log burning woodstoves keeping the unit clean and free of ash is essential for peak performance Too much ash build up hampers airflow and reduces the unit s efficiency and can cause smoke back See the DVD for cleaning tips Daily Ash Maintenance Press the OFF touch pad and allow the stove to shutdown approx five 5 mi

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - LABOT  TELL1 Board - Physikalisches Institut Heidelberg  Manual - Politek Maquinaria  Skyhunter manual  ƒ• ƒ  DLC – SPY maintainance tool User manual  Efficient on-line monitoring of river water quality using  Chief Flat Panel Fixed Wall Mount  GPS18185HR - User`s Manual - RTD Embedded Technologies, Inc.  préparation permettant la reconstitution du potentiel  