Home
engine-driven aluminum water pump model 7rlag-2kst, 6rlag
Contents
1. ENGINE DRIVEN ALUMINUM WATER PUMP MODEL 7RLAG 2KST 6RLAG 2LST 6RLAG 3LST 6RLAG 3HST SAFETY WARNINGS BEFORE OPERATING OR INSTALLING THIS PUMP READ THIS MANUAL AND FOLLOW ALL SAFETY WARNINGS AND OPERATING INSTRUCTIONS A WARNING Carefully read the safety messages in this manual and on the pump Keep this manual with the pump at all times A ATTENTION RENTAL COMPANIES AND PRIVATE OWNERS WHO RENT OR LEND THIS WATER PUMP TO OTHERS All persons to whom you rent or lend this pump must have access to and read this owner s manual Keep this manual with the pump at all times and advise all persons who will operate the pump to read it You must also provide personal instruction on how to safely operate the pump and you must be available to answer any questions that the renter or borrower might have A WARNING When running the engine on this pump produces carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death e Operate this pump ONLY outdoors e Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings APPLICATION Use this pump for water only where the vertical suction head from the water level is 25 ft 8m or less Head refers to the height of a column of water that can be delivered by the discharge of the pump Figure 1 Suction head or suction lift is the vertical distance be
2. Fill crank case to the proper level Place pump on a flat level surface 4 Excessive suction lift must take into consideration a Restricted suction a Size and length of pipe b Excessive suction lift b Pipe fitting 3 The seal may be damaged due to c Elevation above sea level a Normal wear Including all of the above we recommend that the total suction head b Overheating not exceed 25 ft c Pumping chemicals that this seal is not designed for 2 An excessively worn impeller is mainly caused from cavitation Contact an authorized service depot for further assistance which is caused by a number of situations such as MAINTENANCE a ENGINE Refer to the engine manufacturer s instructions for any has drained run the pump for a few seconds to get the last of maintenance requirements the water out of the casing Make sure the suction and discharge b DRAINING Ifthe pump is subject to freezing temperatures drain lines are free of water it by removing the drain plug and priming plug After the water A WARNING Store the pump in a well ventilated area away from heat flame or sparks LIMITED WARRANTY For warranty consideration Franklin Electric Company Inc and its subsidiaries hereafter the Company warrants that the products specified in this warranty are free from defects in material or workmanship of the Company During the time periods and subject to the terms and conditions hereinafter set forth the Company will
3. In a flooded suction situation the pump will discharge the water almost immediately If the suction line is above the water level being pumped it will take a few minutes to lift the water to the casing and then to discharge it If the suction line is quite long the pump may overheat before the water in the suction line reaches the pump In this case turn the pump off and drain the casing Wait a few minutes for the seal in the pump casing to cool down CAUTION If the overheated casing is filled while hot damage to the seal will occur Replace the drain plug and refill the casing with water Replace the priming plug and restart the pump Discharge head Typical water pump Total head Suction head 25 ft 8 m max FIGURE 1 TROUBLESHOOTING PROBLEMS CAUSES SOLUTIONS Pump will not pump Air leak in suction line Make sure suction hose is double clamped at joints clamps are tight fittings have thread compound and are tight with no nicks or cuts in hose The suction and or discharge line s may be blocked or the Check to see that the lines and valves are in good working order valve s are closed faulty and or blocked The end of the suction line is not submerged Increase its length or move pump closer to source of liquid Total head is too high for this pump to work against Reduce total head or use a higher head pump Pump will
4. Les conduites d aspiration et ou de refoulement peuvent tre blo qu es ou les clapets sont ferm s d fectueux ou bloqu s V rifier si les conduites et les clapets sont en bon tat de fonction nement The end of the suction line is not submerged Increase its length or move pump closer to source of liquid L extr mit de la conduite d aspiration n est Augmenter sa longueur ou rapprocher la pompe de pas im merg e la source de liquide pomper La pompe ne s amorce La hauteur g om trique d aspiration est trop lev e 1 Rapprocher la pompe de la source de liquide a pomper L amorgage est tr s long La conduite d aspiration est tr s longue Consulter le paragraphe D marrage de la section Fonc tionnement ll y a des poches d air ou des fuites dans la conduite d aspiration V rifier si les raccords de la conduite sont serr s Le rendement de la pompe est inf rieur au rendement pr vu Le d bit est limit a accumulation de d bris b soupapes d fectueuses ou semi ouvertes c le diam tre des tuyaux ou des boyaux utilis s est plus petit que celui des orifices de la pompe a Nettoyer les conduites et les raccords b V rifier si les soupapes sont en bon tat de fonctionnement c Augmenter le diam tre des tuyaux ou des boyaux afin de r duire les pertes dues au frottement L extr mit de la conduite d aspiration n est pas suff
5. Electric Company Inc y sus subsidiarios denominada de ahora en adelante la Compania garantiza que los productos especificados en esta garantia estan libres de defectos en los materiales y en la mano de obra de la Compania Durante el periodo y sujeto a los t rminos estipulados en este documento la Compania reparara o reemplazara al cliente o usuario original cualquier parte del producto que presente defectos materiales o de fabricaci n atribuibles a la compa a En todo momento la Compa a tendr y poseer el nico derecho y opci n de determinar si repara o reemplaza el equipo piezas o componentes defectuosos La Compa a tiene la opci n de inspeccionar cualquier producto devuelto bajo los t rminos de la garant a para confirmar que est cubierto por la garant a antes aprobar la reparaci n o reemplazo seg n la garant a Esta garant a constituye la Unica obligaci n de la Compa a y es el nico recurso que tiene el cliente si el producto tiene defectos Devuelva el producto defectuoso al sitio de compra para que sea considerado bajo la garant a DURACI N DE LA GARANT A PRODUCTOS 24 meses a partir de la fecha de compra por el cliente Los cepillos el impulsor o la leva en los modelos con motor de cepillo y o los impulsores de aletas flexibles no est n cubiertos por la garant a En caso de que no exista un comprobante adecuado de la fecha de compra el per odo efectivo de esta garant a comenzar a partir de la fech
6. a un voltaje distinto al que se indica en la placa de identificaci n La bomba se utiliz con fluidos distintos al agua dulce a temperatura ambiente aproximadamente La bomba funcion sin l quido se cort el suministro de l quido El cliente abri el alojamiento sellado del motor o desarm el producto El cable se cort a un largo menor que 0 9 m 3 pies EXENCI N DE RESPONSABILIDAD Toda afirmaci n verbal con respecto al producto por parte del vendedor la Compa a los representantes o cualquier otra parte no constituye garant a alguna no debe ser considerada como tal por el usuario y no forma parte del contrato de venta La nica obligaci n del vendedor y la Compa a y el nico recurso del comprador ser el reemplazo y o reparaci n que har la Compa a del producto tal como se describi anteriormente NI EL VENDEDOR NI LA COMPA A SER N RESPONSABLES POR CUALQUIER LESI N P RDIDA O DA O DIRECTO INCIDENTAL O INDIRECTO LO QUE INCLUYE SIN LIMITACI N DA OS INCIDENTALES O INDIRECTOS POR P RDIDA DE GANANCIAS DE VENTAS LESIONES PERSONALES O MATERIALES O CUALQUIER OTRO DA O INCIDENTAL O INDIRECTO QUE RESULTARA DEL USO O INCAPACIDAD DE USAR EL PRODUCTO Y EL USUARIO ACUERDA QUE NO HAY NING N OTRO RECURSO Antes de usarlo el usuario deber determinar la idoneidad del producto para el uso propuesto y asumir todos los riesgos y toda la responsabilidad que ello implique LA GARANT A Y RECURSO DESCRITOS EN ESTA GA
7. described above NEITHER SELLER NOR THE COMPANY SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS LOST SALES INJURY TO PERSON OR PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT AND THE USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT Before using the user shall determine the suitability of the product for his intended use and user assumes all risk and liability whatsoever in connection therewith THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY EXPRESSED OR IMPLIED WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT EITHER APPLIES TO A PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESSED WARRANTIES GIVEN ABOVE Some states and countries do not allow the exclusion or limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country United States 301 North MacArthur Boule
8. la salida de descarga de la bomba y el punto de descarga Altura total es la suma de la altura de succi n y la altura de descarga Se debe tomar en INSTALACI N a UBICACI N Para una instalaci n permanente ponga la bomba en un lugar limpio seco y ventilado Mantenga la l nea de suc ci n lo m s corta posible El mantenimiento de la longitud de la ca er a lo m s corta posible permitir que la bomba funcione al m ximo de su eficiencia y tambi n asegurar que la carcasa no se recaliente debido a la ausencia de agua Figura 1 b INSTALACI N Instale la bomba sobre unos cimientos r gidos para eliminar su movimiento por la vibraci n c L NEADE SUCCI N Use unal nea de succi n del mismo tama o que la succi n de la bomba Si la tuber a de succi n es larga aumente por un tama o para mejorar el flujo Incline la tuber a de succi n hacia arriba para evitar bolsas de aire en la misma y un cargado dif cil e No haga funcionar la bomba dentro de ning n edificio rea cerrada o recintos tales como s tanos garajes o lugares similares aunque est n abiertas las puertas y las ventanas e Aseg rese que todas las conexiones est n bien ajustadas Nunca la use con l quidos inflamables e Apague el motor antes de darle servicio e Si se derrama combustible evite el crear una fuente de encendido hasta que se hayan limpiado y eliminado los vapores del combustible e Revise las instrucciones antes de hacerla funcio
9. not prime Excessive suction lift 1 Move the pump closer to liquid source Priming takes a Suction line is quite long Refer to START UP under OPERATION long time Air pockets or leaks in the suction line Check the line for loose connections Pump does not Flow is restricted due to perform as well as a Debris build up a Clean the lines and fittings it should b Faulty or semi open valve s b Check to see that the valves are in good working order c Pipe or hose used is smaller than the thread sizes on the pump c Increase the size of hose or pipe to reduce friction losses Insufficient submergence of the end of suction line The end of the suction line must be submerged Excessively worn impeller 2 Replace impeller Seal is damaged 3 Liquid will be leaking through the middle Replace the seal of the adapter Air pockets or leaks in the suction line Check suction line Clogged impeller Remove casing to clean out Pump loses prime Water level drops below the end of the suction line Increase length of suction line or move the pump closer to the water source Pump will not start No fuel Add fuel Faulty spark plug Replace spark plug Pump will not start Low oil level Fill crank case to the proper level or starts but runs Place pump on a flat level surface hl roughy Choke in wrong position Adjust choke Spark plug wire loose Attach wire to spark plug Pump shuts down No fuel Add fuel during operation Low oil level
10. plaque signal tique La pompe a t utilis e avec des liquides autres que de l eau douce approximativement la temp rature ambiante La pompe a fonctionn sec alimentation en liquide coup e Le carter moteur scell a t ouvert ou le produit a t d mont par le client Le cordon a t coup une longueur inf rieure 0 9 m 3 pieds AVIS DE NON RESPONSABILIT Toute d claration verbale portant sur le produit faite par le vendeur l Entreprise les repr sentants ou toute autre partie ne constitue pas une garantie et ne peut tre consid r e par l utilisateur comme faisant partie du contrat de vente La seule obligation du vendeur ou de l Entreprise et le seul recours de l acheteur est le remplacement et ou la r paration du produit par l Entreprise comme il est d crit ci dessus LE VENDEUR OU L ENTREPRISE NE PEUT ETRE TENU RESPONSABLE POUR TOUTE BLESSURE PERTE OU DOMMAGE DIRECT INDIRECT OU CONSECUTIF INCLUANT MAIS SANS S Y LIMITER LES DOMMAGES INDIRECTS OU CONSECUTIFS LIES A UNE PERTE DE PROFITS UNE PERTE DE VENTES DES BLESSURES OU DES DOMMAGES MATERIELS OU TOUT AUTRE INCIDENT OU PERTE CONSECUTIVE RESULTANT DE L UTILISATION OU DE L IMPOSSIBILIT D UTILISER LE PRODUIT DE PLUS L UTILISATEUR ACCEPTE QU AUCUN AUTRE RECOURS N EST DISPONIBLE Avant de commencer utiliser le produit l utilisateur doit d terminer si ce produit est adapt l usage pr vu et l utilisateur assume tous les risques e
11. pose et ou de la r paration d un produit d une partie ou d un composant AM LIORATIONS DU PRODUIT L Entreprise se r serve le droit de modifier ou d am liorer ses produits ou une quelconque de leur partie sans obligation de fournir une telle modification ou am lioration aux appareils d j vendus et ou exp di s avant que de telles modifications ou am liorations n aient t apport es CONDITIONS ET MODALIT S G N RALES Cette garantie ne couvre pas les dommages caus s par une catastrophe naturelle usure normale la foudre ou des conditions hors du contr le de l Entreprise et elle ne couvre pas non plus les services d entretien normaux et aux pi ces us es associ s un tel service ni les produits qui selon le jugement exclusif de l Entreprise ont t expos s la n gligence l abus un accident une application inappropri e une alt ration une modification ni aux dommages caus s par une installation une utilisation un entretien ou un entreposage inad quat ni une utilisation au del des maximums La garantie est NULLE si l une des conditions suivantes s applique 1 Le produit est utilis pour des applications autres que celles pour lesquelles il a t con u et fabriqu 2 Le produit n est pas install dans le respect des codes et r glements applicables et selon les bonnes pratiques accept es dans l industrie Le produit a t branch une tension autre que celle indiqu e sur la
12. satisfaisants Si la pompe ne fournit pas le rendement indiqu v rifier l installation et suivre soigneusement les instructions et le guide de d pannage d TUYAU D ASPIRATION Enduire d une graisse lubrifiante a joint filet tous les joints du tuyau Bien serrer tous les raccords ll est recommand d utiliser des tuyaux propres et non corrod s Une cumoire de succion est requise pour filtrer les mat riaux abrasifs e BOYAU D ASPIRATION En cas de pompage vertical ajouter un coude pour viter la torsion du boyau Utiliser des colliers de serrage doubles sur tous les joints du boyau Bien serrer tous les raccords NOTE Sivousutilisezlapompe pour des travaux d ass chement raccorder un clapet de pied l extr mit de la conduite d aspiration NOTE La cause principale des probl mes de pompage est due une fuite dans la conduite d aspiration M me une fuite minime r duit consid rablement l amor age et le pompage FONCTIONNEMENT A MISE EN GARDE DE NE PAS FAIRE FONCTIONNER LA POMPE A SEC AVANT L AMORGAGE SINON LE JOINT D ETANCHEITE ET LA ROUE DE TURBINE SERAIENT ENDOMMAGES DE FA ON PERMANENTE a PR PARATION DU MOTEUR Suivre les instructions du fabricant avant de mettre le moteur en marche AMORGAGE DE LA POMPE Retirez le bouchon d amorgage et remplissez compl tement le carter d eau puis reboucher Si la pompe est sous le niveau de l eau qui sera pomp e succion inond e la pomp
13. BLA PARA SOLUCIONAR PROBLEMAS PROBLEMAS CAUSAS SOLUCIONES La bomba no Hay fuga de aire en la linea de succi n Aseg rese que la manguera de succi n est con doble abra bombea zaderas en las uniones que est n bien ajustadas que los acoplamientos tengan compuesto en las roscas y que est n bien ajustados que no haya doblez ni cortes en la manguera Las l nea s de succi n y o descarga pueden estar bloqueadas Aseg rese que las l neas y v lvulas est n en buenascondi O la v lvula s puede estar cerrada s falladas y o bloqueadas ciones de funcionamiento El extremo de la l nea de succi n no est gido fuente del l quido La elevaci n total es demasiada para esta bomba Reduzca la elevaci n total o use una bomba con mayor el evaci n La bomba no man La altura de succi n es demasiada 1 tiene la carga Coloque la bomba m s cerca de la fuente del l quido Aumente el largo o coloque la bomba m s cerca de la sumer El cargado toma La l nea de succi n es muy larga Vea la secci n de Encendido bajo Funcionamiento mucho tiempo Hay bolsas de aire o fugas en la l nea de Vea que no haya conexiones flojas en la l nea succi n La bomba no El flujo est restringido debido a funciona tan bien a Acumulaci n de desperdicios a Limpie las l neas y los acoplamientos como deber a b V lvula s fallada o semi abierta b Aseg rese que las v lvulas est n funcionando bie
14. RANT A LIMITADA REPRESENTAN UNA GARANT A Y RECURSO EXCLUSIVOS Y SE OFRECEN EN LUGAR DE CUALQUIER OTRA GARANT A O RECURSO EXPL CITO O IMPL CITO POR EL PRESENTE SE EXCLUYEN EXPL CITAMENTE OTRAS GARANT AS Y RECURSOS INCLUSO PERO SIN LIMITARSE A CUALQUIER GARANT A IMPL CITA DE COMERCIALIZACI N O IDONEIDAD PARA UN PROP SITO ESPEC FICO EN LA MEDIDA EN QUE CORRESPONDA A UN PRODUCTO LA GARANT A ESTAR LIMITADA EN DURACI N A LOS PER ODOS DE LAS GARANT AS EXPRESAS DESCRITAS ANTERIORMENTE Algunos estados y pa ses no permiten la exclusi n o las limitaciones sobre la duraci n de las garant as impl citas ni la exclusi n o limitaci n de responsabilidades por da os incidentales o indirectos por lo que puede que las exclusiones o limitaciones anteriores no correspondan en su caso particular Esta garant a le otorga a usted derechos legales espec ficos y es posible que usted tambi n tenga otros derechos que var an seg n el estado o pa s RE Gri United States 301 North MacArthur Boulevard Oklahoma City Oklahoma 73127 Canada 101 310 De Baets Street Winnipeg Manitoba R2J 0H4 Phone 800 621 7264 Fax 204 255 5214 E mail wts orders fele com www redlionproducts com 998739 Rev 003 4 14
15. a de fabricaci n del producto MANO DE OBRA Y OTROS COSTOS La Compa a DE NINGUNA MANERA ser responsable por el costo de la mano de obra en el campo u otros cargos en que incurra cualquier cliente al retirar y o instalar alg n producto pieza o componente MEJORAS AL PRODUCTO La Compa a se reserva el derecho de cambiar o mejorar sus productos o cualquier parte de los mismos sin que por ello tenga la obligaci n de realizar dicho cambio o mejora en las unidades vendidas y o despachadas con anterioridad T RMINOS Y CONDICIONES GENERALES Esta garant a no tiene efecto si los da os se deben a fuerza mayor desgaste por uso normal servicios de mantenimiento normal y la piezas utilizadas para dicho servicio rayos o condiciones que est n fuera del alcance de la Compa a como tampoco tendr vigencia en aquellos productos que a criterio exclusivo de la Compa a hayan sido sujetos a negligencia maltrato accidente mal uso manipulaci n indebida alteraci n o instalaci n funcionamiento mantenimiento o almacenamiento indebidos o si se sobrepasan los valores m ximos recomendados estipulados en estas instrucciones Esta garant a quedar ANULADA si se hallan cualesquiera de las siguientes condiciones El producto se utiliza para prop sitos distintos a aquellos para los cuales fue dise ado y fabricado El producto no fue instalado de conformidad con las normas reglamentos y pr cticas comerciales aceptadas El producto se conecta
16. ajes de seguridad en este manual y en la bomba A ATENCION A LAS COMPANIAS DE ALQUILER Y LOS PROPIETARIOS PARTICULARES QUE ALQUILAN O PRESTAN ESTA BOMBA DE AGUA A TERCEROS Todas las personas a quienes alquile o preste esta bomba deben tener acceso a este manual del propietario y leerlo Conserve este manual junto a la bomba en todo momento y recomiende leerlo a todas las personas que hagan funcionar la bomba Tambi n debe proporcionar instrucci n personal sobre c mo operar con seguridad la bomba y debe estar disponible para responder cualquier pregunta que pudiera tener quien la alquile o a quien la preste A ADVERTENCIA Cuando esta en funcionamiento el motor de esta bomba produce mon xido de carbono un gas t xico que es inodoro e incoloro Respirar mon xido de carbono puede provocar n useas desmayos o la muerte Opere esta bomba SOLO al aire libre e Evite que el gas emitido ingrese en un rea cerrada a trav s de ventanas puertas tomas de ventilaci n u otras aberturas APLICACI N Utilice esas bombas solamente para agua donde la succi n vertical desde el nivel del l quido sea 25 pies 7 6 m o menos 7 La altura se refiere a la altura de la columna de agua que puede producir la descarga de la bomba Altura de succi n o elevaci n de succi n es la distancia vertical entre el centro de la bomba y la superficie del l quido en el lado de succi n de la bomba Altura de descarga es la distancia vertical entre
17. arranty shall not apply to damage due to acts of God normal wear and tear normal maintenance services and the parts used in connection with such service lightning or conditions beyond the control of the Company nor shall it apply to products which in the sole judgment of the Company have been subject to negligence abuse accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to excess of recommended maximums as set forth in the instructions Warranty will be VOID if any of the following conditions are found Product is used for purposes other than those for which it was designed and manufactured Product not installed in accordance with applicable codes ordinances and good trade practices Product connected to voltage other than indicated on nameplate Pump used to circulate anything other than fresh water at approximately room temperature Pump allowed to operate dry fluid supply cut off Sealed motor housing opened or product dismantled by customer NOR Nie Cord cut off to a length less than three feet DISCLAIMER Any oral statements about the product made by the seller the Company the representatives or any other parties do not constitute warranties shall not be relied upon by the user and are not part of the contract for sale Seller s and the Company s only obligation and buyer s only remedy shall be the replacement and or repair by the Company of the product as
18. e se remplit automatiquement quand les valves sont ouvertes et le moteur peut donc tre mis en marche A MISE EN GARDE NE PAS FAIRE FONCTIONNER CETTE POMPE A SEC c D MARRAGE D marrez la pompe Lorsque l aspiration est noy e la pompe vacuera l eau pratiquement imm diate b ment Si la ligne de succion est au dessus du niveau d eau pomper quelques minutes s couleront avant que le bo tier se remplisse et se vide par la suite Si la conduite d aspiration est tr s longue la pomppe pourrait surchauffer avant que l eau de la ligne de succion n arrive 4 la pompe Le cas ch ant arr ter la pompe et vidanger le bo tier Attendre quelques minutes pour que le joint de la pompe se refroidisse MISE EN GARDE Si le bo tier surchauff se remplit pendant qu il est chaud le joint subira des dommages Replaces alors le bouchon et remplissez le carter d eau de nouveau Hauteur de refoulement Pompe eau typique Hauteur totale Hauteur totale de charge l aspiration 8m 25 ft max FIGURE 1 GUIDE DE D PANNAGE PROBL MES CAUSES PROBABLES SOLUTIONS La pompe ne fonc Fuite d air dans la conduite d aspiration S assurer que les joints du tuyau d aspiration ont un double collier tionne pas de serrage que les colliers sont bien serr s que les raccords ont t garnis de produits pour tanch it et qu ils sont serr s que le tuyau n est ni br ch ni coup
19. ento Llene el carter hasta el nivel adecuado Coloque la bomba sobre una superficie plana y nivelada 1 La altura de succi n excesiva debe tener en cuenta a El tama o y largo de la tuber a b Acoplamientos de la tuber a c Elevaci n sobre el nivel del mar Incluyendo todo lo anterior recomendamos que el total de la altura de succi n total no exceda los 25 pies 2 Un propulsor excesivamente desgastado es causado principal mente por cavitaci n lo cual puede ser causado por un n mero de situaciones Ejemplos a Succi n restringida b Altura de succi n excesiva 3 El sello puede estar da ado debido a a Desgaste normal b Recalentamiento c Bombeo de qu micos para los que el sello no est dise ado P ngase en contacto con un almac n de servicio autorizado para obtener m s ayuda MANTENIMIENTO a MOTOR Vea en las instrucciones del fabricante cualquier req uerimiento de mantenimiento b DRENAJE Si la bomba va a estar expuesta a temperaturas congelantes drene la bomba quitando los tapones de drenaje y de cargado Una vez que el agua ha sido drenada haga funcionar la bomba durante unos segundos a fin de extraer el agua que se encuentra dentro de la carcasa Aseg rese que las l neas de succi n y descarga est n sin l quido ADVERTENCIA Mantenga la bomba en un rea ventilada lejos del calor llamas o chispas 11 GARANTIA LIMITADA Para consideraciones de la garantia Franklin
20. isamment immerg e Il faut immerger l extr mit de la conduite d aspiration La roue de turbine est trop us e 2 Remplacer la roue de turbine Le joint est endommag 3 Du liquide s coule du centre de l adaptateur Remplacer le joint Il y a des poches d air ou des fuites dans la conduite d aspiration V rifier la conduite d aspiration La roue de turbine est obstru e Enlever le bo tier pour le nettoyer La pompe se d samorce Le niveau de liquide est inf rieur l extr mit de la conduite d aspiration Augmenter la longueur de la conduite d aspiration ou rapprocher la pompe de la source de liquide pomper La pompe ne d marre pas Pas de carburant Ajouter du carburant Bougie d allumage d fectueuse Remplacer la bougie d allumage La pompe ne d marre pas ou a des rat s Faible niveau d huile Remplir le carter du moteur au niveau qui convient Placer la pompe sur une surface plane et de niveau L trangleur est dans la mauvaise position Ajuster l trangleur C ble de bougie d allumage desserr Fixer le cable a la bougie La pompe s arr te subitement Pas de carburant Ajouter du carburant Faible niveau d huile Remplir le carter du moteur au niveau qui convient Placer la pompe sur une surface plane et de niveau 1 Pour pomper a une hauteur excessive tenir compte de a Le diam tre et la l
21. issement ou la mort e Utiliser cette pompe l ext rieur SEULEMENT __ Emp cher les gaz d chappement de p n trer dans une zone confin e que ce soit par des fen tres des portes des bouches de ventilation ou par toute autre ouverture UTILISATION Utilisez ces pompes pour l eau seulement quand la succion verticale partir du niveau du liquide est de 8 m 25 pi ou moins 7 L a hauteur de charge se rapporte la hauteur d une colonne d eau pouvant tre produite par l vacuation de la pompe La hauteur totale de charge l aspiration est la distance verticale entre le centre de la pompe et la surface du liquide sur le c t aspiration de la pompe La hauteur de refoulement est la distance verticale entre l orifice d vacuation de la pompe et le point d vacuation La hauteur totale de charge est la somme de la hauteur totale de charge INSTALLATION a EMPLACEMENT En cas d installation permanente placer la pompe dans un endroit propre sec et a r La longueur de la conduite d aspiration doit tre r duite au minimum afin de permettre un d bit maximum Conserver le conduit d alimentation aussi court que poxxible permettra la pompe de vonctionner a sa performance maximale et d assurer que le carter ne devient pas surchauff en raison de l absence de l eau Figure 1 b MONTAGE Fixer la pompe sur une base rigide pour liminer le d placement d la vibration c CONDUITE D ASPIRATION Utiliser
22. n c Las tuberias mangueras usadas son m s peque as que el c Aumente el tama o de la tuberia manguera para reducir la tama o de rosca de la bomba p rdida por fricci n El extremo de la l nea de succi n no est sumergida lo sufi El extremo de la l nea de succi n debe estar sumergido ciente El propulsor est excesivamente gastado 2 Reemplace el propulsor adaptador Hay bolsas de aire o fugas en la l nea de succi n Revise la l nea de succi n Propulsor atorado Quite el cuerpo de la bomba para limpiar El sello est da ado 3 Habr fuga de l quido por el medio del Reemplace el sello La bomba pierde la El nivel del l quido baja por debajo del extremo de la linea de Aumente el largo de la linea de succi n o coloque la bomba m s carga succi n cerca de la fuente del l quido La bomba no ar No tiene combustible Agregue combustible ranca Buj a de encendido defectuosa Reemplace la buj a de encendido La bomba no ar Bajo nivel de aceite ranca o arranca Llene el carter hasta el nivel adecuado Coloque la bomba sobre una superficie plana y nivelada ero anda mal mabe p Obturador en posici n incorrecta Ajuste el obturador Cable de bujia de encendido suelto La bomba se apaga No tiene combustible Conecte el cable a la bujia de encendido Agregue combustible durante el funcion 2 Bajo nivel de aceite ami
23. nar e Use protectores de o dos para reducir la bulla molesta Ah PRECAUCI N NO HAGA FUNCIONAR LA BOMBA EN SECO consideraci n la altura sobre el nivel del mar y las p rdidas por fricci n PRECAUCI N No haga funcionar esta bomba en seco Se requiere solo agua para lubricar la junta de la bomba Esta bomba ha sido probada y hecha funcionar bajo condiciones reales de trabajo El motor la bomba y todos los acoplamientos fueron encontrados en estado satisfactorio Si la unidad de bombeo no funciona como se especifica revise cuidadosamente la gu a de instalaci n y la tabla para solucionar problemas d TUBER A DE SUCCI N Utilice un compuesto para rosca en todas las uniones de las tuber as Las conexiones deben estar bien ajustadas Se recomienda se utilice tuber as limpias y sin corrosi n e MANGUERA DE SUCCI N Si la linea de succi n est b sica mente vertical utilice un codo en la manguera para evitar que se doble Utilice abrazaderas dobles en todas las uniones de man gueras Las conexiones deben estar bien ajustadas Se requiere el uso de una malla para el filtrado del material abrasivo NOTA Si usa la bomba para remover agua instale una v lvula de chequeo en la l nea de succi n La mayor a de problemas de bombeo es una fuga en la l nea de succi n A n una fuga muy peque a reduce enormemente el cargado y bombeo NOTA DANARSE PERMANENTEMENTE a COMO PREPARAR EL MOTOR Siga las instruccio
24. nes del fabricante antes de hacerla funcionar b C MO CARGAR LA BOMBA Extraiga el tap n de cebado y llene la carcasa con agua hasta completar Vuelva a colocar el tap n Si la bomba se encuentra por debajo del nivel del agua que deber ser bombeada succi n por anegamiento la bomba se llenar autom ticamente cuando se abran las v lvulas A PRECAUCION iNO HAGA FUNCIONAR LA BOMBA EN SECO c ENCENDIDO Prenda la bomba En la situaci n de succi n in undada la bomba descargar el agua casi inmediatamente Si la ca er a de succi n se encuentra por encima del nivel del agua que FUNCIONAMIENTO A PRECAUCI N NO OPERAR LA BOMBA ANTES DE CARGARLA EL SELLO Y EL PROPULSOR PODR AN ser bombeada tomar unos minutos para llevar el agua al cuerpo de la bomba y descargarla Si la l nea de succi n es muy larga la bomba podr recalenstarse debido a que el agua dentro de la ca er a de succi n est alcanzando la bomba En este caso apague la bomba y drene el cuerpo de la bomba Espere unos minutos para que se enfrien el sello en el cuerpo de la bomba PRECAUCI N Si se llena el cuerpo de la bomba mientras ste est recalentado se puede da ar el sello Coloque luego el tap n y llene la carcasa con agua Vuelva a colocar el tap n de cargado y encienda la bomba nuevamente Altura de descarga Bomba de agua t pica Altura total Altura de succi n 8 m 25 ft max FIGURA 1 10 TA
25. ongueur du tuyau b Les raccords de tuyauterie c L l vation au dessus du niveau de la mer En consid rant tous les facteurs ci dessus nous recommandons que la hauteur de pression d aspiration totale ne d passe pas 25 pi 2 Lusure excessive de la roue de turbine est principalement due a la cavitation Un certain nombre de situations peuvent entrainer la cavitation Exemples 3 a L aspiration est limit e b La hauteur g om trique d aspiration est trop lev e Le joint peut tre endommag pour les raisons suivantes a Usure normale b Surchauffe c Pompage de produits chimiques pour lesquels le joint n est pas con u Contacter un centre de service autoris pour obtenir de l aide sup pl mentaire ENTRETIEN a b MOTEUR Pour les exigences d entretien du moteur consulter les directives du fabricant VIDANGE Si la pompe est expos e au gel vidanger la pompe en enlevant les bouchons de vidange et d amor age Quandl eau a t vidang e faites fonctionner la pompe pendant quelques secondes pour vacuer l eau r siduelle du carter S assurer galement que les conduites d aspiration et de refoulement sont vides AVERTISSEMENT Garder la pompe dans un endroit a r loin de la chaleur de flammes ou d tincelles GARANTIE LIMITEE Lors des requ tes en garantie Franklin Electric Company Inc et ses filiales ci apr s appel e l Entreprise garantit les produits
26. repair or replace to the original user or consumer any portion of this product which proves defective due to materials or workmanship of the Company At all times the Company shall have and possess the sole right and option to determine whether to repair or replace defective equipment parts or components The Company has the option to inspect any product returned under warranty to confirm that the warranty applies before repair or replacement under warranty is approved This warranty sets forth the Company s sole obligation and purchaser s exclusive remedy for defective product Return defective product to the place of purchase for warranty consideration WARRANTY PERIOD PRODUCTS 24 months from date of purchase by the user No warranty on brushes impeller or cam on models with brush type motors and or flex vane impellers In the absence of suitable proof of the purchase date the effective period of this warranty will begin on the product s date of manufacture LABOR ETC COSTS The Company shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and or affixing any product part or component thereof PRODUCT IMPROVEMENTS The Company reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and or shipped prior to such change or improvement GENERAL TERMS AND CONDITIONS This w
27. sp cifi s dans cette garantie contre tout d faut de mat riaux et de main d uvre Pendant les p riodes couvertes par la garantie et selon les conditions indiqu es dans la pr sente l Entreprise r parera ou remplacera toute partie de ce produit pr sentant une d faillance li e aux mat riaux ou la main d uvre et ce uniquement aupr s du premier utilisateur ou acheteur En tout temps l Entreprise conserve le droit et l option de d terminer si un quipement des pi ces ou des composants d fectueux doivent tre r par s ou remplac s L Entreprise peut inspecter tout produit sous garantie qui lui est retourn afin de confirmer que la garantie s applique avant d approuver la r paration ou le remplacement Cette garantie stipule l unique obligation de l Entreprise et le recours exclusif de l acheteur pour un produit d fectueux Retourner le produit d fectueux au d taillant pour les requ tes en garantie P RIODE DE GARANTIE PRODUITS 24 mois partir de la date d achat par l utilisateur Aucune garantie n est offerte pour les balais le rotor ou la came sur les mod les avec moteur balais et ou rotor flexible palettes En l absence d une preuve ad quate de la date d achat la p riode d application commencera partir de la date de fabrication COUTS DE MAIN D CEUVRE ETC EN AUCUN CAS l Entreprise ne pourra tre tenue responsable du co t de la main d uvre ou d autres frais encourus par un client lors de la d
28. t due to the absence of water b MOUNTING Mount the pump on a rigid foundation to eliminate creeping due to vibration c SUCTION LINE Use a suction line the same size as the suction on the pump If the suction pipe is long increase it by one size to improve flow Slope the suction line upwards to the pump to avoid air pockets in the line and hard priming d SUCTION PIPE Use thread compound on all pipe joints Connec tions must be tight and pipe should be clean and uncorroded e SUCTION HOSE If the suction line runs generally vertical use an elbow on the hose to prevent kinking Use double clamps on all hose joints Connections must be tight and a suction strainer is required to filter abrasive material NOTE If you use the pump for dewatering attach a suction screen to the suction line NOTE The main cause of pumping problems is a leak in the suction line Even a tiny leak reduces priming and pumping greatly OPERATION A CAUTION DO NOT RUN THE PUMP BEFORE PRIMING IT THE SEAL AND IMPELLER COULD BE PERMANENTLY DAMAGED a PREPARING THE ENGINE Follow the engine manufacturer s instructions before operating b PRIMING THE PUMP Remove the priming plug fill the casing with water until full and replace the plug If the pump is below the level of the water that will be pumped flooded suction the pump will automatically fill up when the valves are open A CAUTION DO NOT OPERATE THIS PUMP DRY c START UP Start the pump
29. t toutes les responsabilit s qui sont li s cette utilisation LA GARANTIE ET LES MESURES CORRECTIVES D CRITES DANS LA PR SENTE GARANTIE LIMIT E CONSTITUENT UNE GARANTIE ET DES MESURES CORRECTIVES EXCLUSIVES EN LIEU ET PLACE DE TOUTE AUTRE GARANTIE ET MESURE CORRECTIVE EXPRESSE O IMPLICITE ET TOUTE AUTRE GARANTIE ET MESURE CORRECTIVE EST EXPRESS MENT EXCLUE INCLUANT MAIS SANS S Y LIMITER TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE OU D ADAPTATION UN USAGE PARTICULIER Certaines juridictions et certains pays interdisent les exclusions ou les limitations de dur e d une garantie implicite ou l exclusion ou la limitation des dommages indirects ou cons cutifs les limitations ou exclusions ci dessus pourraient donc ne pas s appliquer votre cas Cette garantie vous donne des droits l gaux sp cifiques et vous pourriez galement jouir d autres droits qui varient selon la juridiction ou le pays NOS Y United States 301 North MacArthur Boulevard Oklahoma City Oklahoma 73127 Canada 101 310 De Baets Street Winnipeg Manitoba R2J 0H4 Phone 800 621 7264 Fax 204 255 5214 E mail wts orders fele com www redlionproducts com 8 BOMBA DE AGUA DE ALUMINIO A MOTOR MODELO 7RLAG 2KST 6RLAG 2LST 6RLAG 3LST 6RLAG 3HST ADVERTENCIAS DE SEGURIDAD LEAESTE MANUAL Y SIGATODAS LAS REGLAS DE SEGURIDAD ANTES DE INSTALAR U OPERAR ESTA BOMBA A ADVERTENCIA Lea cuidadosamente estos mens
30. tween the center of the pump and the surface of the liquid on the suction side of the pump Discharge head is the vertical distance between the pump s discharge port and the point of discharge Total head is Do not operate the pump inside any building confined area or enclosure such as basements garages or similar locations even if doors and windows are open Make sure all connections are tight e Never use with flammable fluids e Turn off engine before servicing e If fuel is spilled avoid creating any source of ignition until the fuel vapors have been cleaned up and removed e Review instructions before operating e Wear ear protection to reduce objectionable noise AX CAUTION DO NOT OPERATE THIS PUMP DRY the sum of the suction head and the discharge head The elevation above sea level and friction losses must be taken into consideration CAUTION Do not operate this pump dry Water is required to lubricate pump seal This pump has been tested and operated under actual working conditions Engine pump and all accessories were found satisfactory If the pump is not performing as specified check INSTALLATION and TROUBLESHOOTING sections carefully INSTALLATION a LOCATION For permanent installation put the pump in a clean dry and ventilated place Figure 1 Keep the suction line as short as possible This will allow the pump to operate at maximum performance and to ensure that the casing does not overhea
31. une conduite d aspiration de m me dimension que l orifice d aspiration de la pompe Si la conduite est longue augmenter d une unit pour am liorer le d bit La conduite doit toujours remonter vers la pompe pour viter la pr sence de poches d air dans la conduite et faciliter l amor age 5 e Ne pas utiliser la pompe l int rieur d un difice d une zone confin e ou ferm e comme des sous sols des garages ou d autres emplacements similaires m me si les portes et les fen tres sont ouvertes e S assurer que tous les raccords sont bien serr s Ne jamais utiliser de liquides inflammables e Couper le fonctionnement du moteur avant d effectuer l entretien e Si du carburant est renvers viter de cr er une source d inflammation jusqu la disparition des vapeurs e Passez les instructions en revue avant d utiliser la pompe e Porter un appareil de protection acoustique afin de r duire les effets du bruit MISE EN GARDE NE PAS FAIRE FONCTIONNER CETTE POMPE SEC l aspiration et de la hauteur de refoulement Il faut galement tenir compte de l l vation au dessus du niveau de la mer et des pertes dues au frottement MISE EN GARDE Ne pas faire fonctionner la pompe vide L eau est requise pour lubrifier le joint tanche de la pompe Le fonctionnement de la pompe a t v rifi dans des conditions de travail r elles Le moteur la pompe et tous les accessoires ont t jug s
32. vard Oklahoma City Oklahoma 73127 Canada 101 310 De Baets Street Winnipeg Manitoba R2J 0H4 Phone 800 621 7264 Fax 204 255 5214 E mail wts orders fele com www redlionproducts com 4 POMPE A EAU EN ALUMINIUM ENTRAINEE PAR MOTEUR MODELE 7RLAG 2KST 6RLAG 2LST 6RLAG 3LST 6RLAG 3HST 4h CONSIGNES DE S CURIT AVANT D INSTALLER OU D UTILISER CETTE POMPE PRIERE DE LIRE LE PRESENT GUIDE ET SUIVRE TOUTES LES REGLES DE SECURITE ET IN STRUCTIONS D UTILISATION 4h AVERTISSEMENT Lire attentivement les avis de s curit se trouvant dans le pr sent manuel et sur la pompe Conserver ce manuel avec la pompe en tout temps ATTENTION ENTREPRISES DE LOCATION ET PROPRI TAIRES PRIV S QUI LOUEZ CETTE POMPE EAU D AUTRES UTILISATEURS Toutes les personnes qui cette pompe est lou e ou pr t e doivent avoir acc s et lire ce manuel de l utilisateur Conserver ce manuel avec la pompe en tout temps et aviser tout utilisateur de cette pompe de lire ce manuel Il vous incombe galement de fournir des instructions personnelles sur l utilisation s curitaire de la pompe et d tre pr t r pondre toute question que pourrait poser la personne qui loue ou emprunte la pompe A AVERTISSEMENT Lorsqu il fonctionne le moteur de cette pompe produit du monoxyde de carbone un gaz toxique sans odeur et sans couleur L inhalation de monoxyde de carbone peut causer des naus es un vanou
Download Pdf Manuals
Related Search
Related Contents
Impression LCD Speakerphone Station User Guide Minka Lavery 1238-580 Instructions / Assembly OPERATING INSTRUCTIONS for IS-mini (PDF:1.4MB) Raspberry Pi 832-6274 PC User Manual - Run Distribution La notion de > chez Daniil Harms premières pages - R TLD212 Manuale Utente - Funzionamento con Tastiera Copyright © All rights reserved.
Failed to retrieve file