Home

installation manual

image

Contents

1. 120 V can only be installed on standard 2 dimensions Diapason gearbox octagonal conduit box size 4 connect black wire from gearbox to black supply wire gearbox connect white wire from gearbox to o z white supply wire E m connect green grounding wire in from conduit to green grounding wire BLACK 120V from gearbox WHITE 277V i GREEN connect supply wires to fixture wires 3 installation align and install octagonal conduit box with proper size wire nuts by others fix Diapason M10 on the bottom part connect male connector of bottom part use hexagonal tool to and connect wires with female connector with female connector of top part fix parts together in case of Diapason T4 bi pin or Small in case of Diapason AR111 connect lam in case of Diapason Base AR111 connect i P P p Diapason MR16 place lamp in lampholder add supplied pin 4 lamp placement with clamps and fix lamp with springs lamp with clamps and fix lamp with spring 5 accessories reflector push in cooling profile lens glass or filter fix to frame with springs Click y SS Ke ARE D aan M glare preventer push until it snaps d E ES y ED q SA glare preventer lens glass or filter use fixation spring 6
2. picture This installation manual might not cover all details or variations When additional information is required please contact your local representa tive or one of the Kreon offices Cette notice de montage ne couvre pas tous les d tails ou les variations Pour des informations suppl mentaires veuillez contacter votre repr sentant local ou un des bureaux Kreon kreon nv Industrieweg Noord 1152 B 3660 Opglabbeek Belgium Tel 52 89 81 97 80 Fax 32 89 81 97 90 www kreon com mailbox kreon be Rev date 05 07 2011 KU8760001561
3. luminaire loin de mat riaux qui peut br ler ne jamais touchez l ampoule utilisez un chiffon doux l huile de la peau peut endommager l ampoule luminaires quipp s avec un verre de s curit doivent oper d un verre de s curit complet et en place le luminaire ne peut tre utilis qu avec des accessoires de Kreon 5 ATTENTION RISQUE D INCENDIE pas utiliser une ampoule con ue seulement pour des luminaires ferm s tere CE min 30 L laisser une distance d au moins 30 du mur convient aux emplacements Je z rex L d int rieur et secs seulement 2 dimensions Diapason Diapason Cover Small Diapason Name Reference Type Lx Wx Diapason Diapason base ku94632_ T4 GY6 35 base 44 5 x 71 5 x 41 2 Diapason base ku94631_ AR111 G53 base 44 5 x 71 5 x 41 2 Diapason Cover base ku94634_ AR111 G53 base 44 5 x 71 5 x 41 2 Small Diapason base ku94630_ MR16 GU5 3 base 4 x 51 2 x 24 5 Small Diapason base ku94620_ LED 4 x 51 2 XD24 5 technics Name Reference LxWxH Voltage h Diapason gearbox ku94632_ 63 5 x 41 8 x 17 10 120 V Diapason gearbox ku94631_ 63 5 x 41 8 x 17 10 120 V Diapason Cover gearbox ku94634_ 63 5 x 41 8 x 17 10 120 V Small Diapason gearbox ku94630_ 63 5 x 41 8 x 17 10 120 V Small Diapason gearbox ku94620_ 63 5 x 41 8 x 17 10
4. es O CAUTION RISK OF FIRE do not install a lamp identified for use only in enclosed luminaires e grounding conductor CE min 30 4 do not install any luminaire closer than 30 from wall suitable for indoor dry nee L_ locations only Notice de montage pour KREON DIAPASON GEARBOX 120V auxiliaire inclus types ku94632_ ku94631_ ku94634_ ku94630_ ATTENTION LIRE ET COMPRENDRE TOUTES LES INSTRUCTIONS AVANT L INSTALLATION CONSERVER CES INSTRUCTIONS POUR DE FUTURES REFERENCES RISQUE D INCENDIE RISQUE DE CHOC INSTRUCTIONS RELATIVES UN RISQUE D INCENDIE OU DE BLESSURE CE PRODUIT DOIT ETRE INSTALL SELON LE CODE D INSTALLATION PERTINENT PAR UNE PERSONNE QUI CONNAIT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHERENTS CONSULTER UN LECTRICIEN QUALIFI POUR VOUS ASSURER QUE LES CONDUCTEURS DE LA D RIVATION SONT AD QUATS COUPER L ALIMENTATION AVANT L ENTRETIEN ASSURER QUE LE LUMINAIRE EST MIS LA TERRE MONTER LE LUMINAIRE EN SURFACE SEULEMENT POUR EMPLACEMENT SECS SEULEMENT POUR REDUIRE LE RISQUE D INCENDIE UTILISER UNE LAMPE INDIQUANT CONVIENT AUX LUMINAIRE OUVERTS ALERTE pour r duire le risque D INCENDIE OU DE BLESSURE coupez l alimentation lectrique et laisser refroidir avant de remplacer l ampoule la lampe chauffe rapidement ne touchez pas l objectif chaud la garde le r flecteur ou une enceinte gardez le
5. kreon technics d notifications IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation instructions for KREON DIAPASON GEARBOX 120V gear inclusive types ku94632_ ku94631_ ku94634_ ku94630_ WARNING READ AND UNDER STAND ALL INSTRUCTIONS BEFORE STARTING INSTALLATION SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE A RISK OF FIRE RISK OF SHOCK INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS THIS LUMINAIRE MUST BE INSTALLED TO CONFIRM WITH NEC AND ALL LOCAL ELECTRICAL amp BUILDING CODES amp PRACTICES TO ASSURE FULL COMPLIANCE WITH LOCAL CODES AND REGULATIONS CONSULT WITH YOUR LOCAL ELECTRICAL INSPECTOR BEFORE INSTALLATION DISCONNECT POWERSUPPLY BEFORE INSTALLING OR SERVICING ENSURE THE LUMINAIRE IS GROUNDED LUMINAIRE IS SURFACE MOUNTED ONLY TO REDUCE RISK OF FIRE DO NOT USE A LAMP IDENTIFIED FOR USE IN ENCLOSED LUMINAIRES SUITABLE FOR INDOOR DRY LOCATIONS ONLY WARNING to reduce the risk of FIRE OR INJURY turn off power and allow to cool before replacing lamp lamp gets HOT quickly contact only switch plug when turning on do not touch hot lens guard reflector or enclosure keep lamp away from materials that may burn do not touch lamp at any time use soft cloth oil from skin may damage the lamp do not operate the luminaire with a missing or damaged shield if required this luminaire can only be used with Kreon accessori

Download Pdf Manuals

image

Related Search

Related Contents

Origin Storage 80GB 5400RPM Notebook Drive  Kenmore 362.71330 Range User Manual  Agilent 218 Purification Solution System User  

Copyright © All rights reserved.
Failed to retrieve file