1. Vertical retrofit housing Bandeau architectural vertical Range Locking devices Gamme Verrouillage INSTALLATION MANUAL MANUEL D INSTALLATION CDVI Group Company Thank you for buying our products and for the confidence you placed in our company 1 PRODUCTS OVERVIEW m NF S 61 937 Available in versions Standard and with or without handle u Pre assembled x Fast installation x Covers previous installation fixing holes Magnets supplied with terminal blocks Pre drilled sections adjustable Ergonomic design m SAA finish Satin Anodised Aluminium m Aesthetic x Suitable for metal wood and glass doors a Ideal for retrofit applications Groove at the back of the magnet housing for cable management Magnet housing supplied with cover Options Aluminium rail spacers Aluminium cable tray Installation on glass door UBK25 RAL colour Cut to size Holding force 2 x 300kg a Dimensions L x W x D BO600RPSTD 2190 x 105 x 63mm BO600RP 2500 x 105 x 63mm Magnet housing for frame mount a Armature housing with end caps for door mount Input voltage 12 24 48V dc Consumption 12 V DC 550mA per magnet 24 V DC 275mA per magnet 48 V DC 190mA For both magnets cdvi com 2 cdvigroup com H R N HIGH RESISTANCE X WEEE MOUNTING CE CE certification 20 C to 70 C Recommended Power supplies we
2. Strip 12Vdc 24Vdc monitored version us 12Vdc or 24Vdc positive mes Time relay for magnetic locks Ref TPV 4 Important When using a timer in circuit please E make note of the voltage used and ensure the LiL timer can operate at the same voltage NC Contact Normally Closed COM Common example shows TPV NO Contact Normally Open Adjustable timer O Voltage 12Vdc or 24Vdc 0 to 20 seconds Place the jumpers to select 12Vdc or 24Vdc supply to your magnetic locks 12Vdc or 24Vdc negative BO600RP RANGE green pere nee From 1 to 3 magnetic 12Vdc 24 Vdc Exit locks depending on model Button eee ei eet Access l Electromagnetic lock Control E Unit o 0 Voltage 12Vdc 300KG or24Vde ni pe D ti S OSOSCSCOC C C C CS SSS Electromagnetic lock emmes g il LE z bd ae E E E ZT 5 Way Terminal Strip non monitored version 300KG i 12Vdc or 24Vdc positive Electromagnetic lock 12Vdc or 24Vdc negative JE Voltage 12Vdc or 24Vdc Place the jumpers to select i 12Vdc or 24Vdc supply to your 300KG magnetic locks cdvi com cdvigroup com 5 CDVI warrants this product to be free from defects in material and workmanship when it has been installed in accordance with the manufacturer s instructions and has not been modified or tampered with Only product recognized by CDVI to be
3. au dos de la notice d installation EXCLUSIONS DE LA GARANTIE A l EXCEPTION DES POINTS EVOQUES PRECEDEMMENT CDVI N APPLIQUE AUCUNE GARANTIE NI DELIBEREE NI TACITE A TOUS LES PROBLEMES INCLUANT LE CONDITIONNEMENT LE TRANSPORT LEUR COMMERCIALISATION OU LES CONDITIONS D UTILISATIONS PARTICULIERES 7 NOTES Voir conditions de garantie vie limit e cdvi com cdvigroup com 11 Reference GO301FRO387V01 Extranet EXE CDVI_IM BO600RP CMYK A5 EN FR 01 Manufacturing Access Control since 1985 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 y CDVI Group FRANCE Headquarter Si ge social Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBERICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 CDVI MAROC Phone 212 0 5 22 48 09 40 Fax 212 0 5 22 48 34 69 pr sent document photos dessins caract ristiques ained within this document photos drawing features specifications
4. defective should be returned under these warranty terms if accompanied by an RMA Return Material Authorization Number provided by CDVI CDVI at its option shall repair or replace the defective product at CDVI premises or at any CDVI approved service center This warranty does not cover any damage due to accident misuse abuse or negligence This warranty is valid only if the product is registered within 1 month from delivery to the final costumer To obtain full details of this warranty and to register the product to commence the Limited Lifetime Warranty complete the enclosed registration card and return it either by e mail or post to the relevant CDVI address or completion of the on line registration at www cdvigroup com Repair or replacement of the defective product is the exclusive remedy CDVI shall not be liable for any incidental or consequential damages arising from any defect in or malfunction of its product In no event the entire liability can not exceed the purchase price of the product The CDVI local country contact details can be found on line by visiting www cdvigroup com or on the back cover of the installation manual DISCLAIMER OF WARRANTY EXCEPT AS STATED ABOVE CDVI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF ITS PRODUCTS THE TRANSPORTATION THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE 7 NOTES Refer to Limited Lifetime Warranty conditio
5. DC Alimentation 12 V ou 24 V DC L L Alimentation 12 V ou 24V DC mes i NC Contact Normalement Ferm COM Commun UL JL NO Contact Normalement Ouvert Alimentation 12 V DC ou 24 V DC En fonction du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC Montage N 2 Contr le d acc s Bouton poussoir int rieur Contr le d acc s ext rieur NF Temporis Alimentation 12 Vou 24 V DC FUIT i e cdvi com 10 cdvigroup com BO600RP De 1 a 3 ventouse 300 kg selon mod le Bouton poussoir 12Vdc 24 V DC NF int rieur pesssemseseenerenennenmn inning D K 2 i VENTOUSE N 1 O Bornier 5 points ventouse Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC Alimentation 12 V DC ou 24 V DC En fonction du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC MANUEL D INSTALLATION FR BO6OORP Bandeau architectural vertical 6 CONDITIONS DE GARANTIE VIE LIMIT E EXTRAIT Les soci t s CDVI garantissent que ce produit est d pourvu de tout vice cach tant dans les mat riaux que dans sa fabrication la condition qu il soit install conform ment aux pr conisations du fabricant et qu il n y ait pas eu d interventions ou de modifications sur le produit La responsabilit de CDVI se limite la r paration ou l change du produit CDVI n assume auc
6. EEE CE Certification CE 20 C 4 70 C Alimentations pr conis es e _ ARD212 BS602 PATENTED EBREVETE cdvi com cdvigroup com 7 BO6OORP 2500 MM Alimentations pr conis es Le bandeau est con u pour des ventouses ayant une force de retenue chacune de 400 Kg aliment es sous 12 V DC ou 24 V DC Pr voir une alimentation suivant le branchement choisi L arriv e de courant se fait cot fixe ou semi fixe l aide d un flexible si n cessaire Il existe deux alimentations adapt es pour le BO6OORP avec 2 ventouses BS602 ou ARD2 12 en 12 V DC ADC24 AS6 ou BS24 en 24 V DC C blage Pr voir du fil 9 10 souple Nous pr conisons une distance maximun de 10 m tres entre la ventouse et son alimentation Si cette distance est sup rieure pr voir le c ble n cessaire l installation 3 L MENTS FOURNIS BO600RPSTD 2190 MM BOGOORP3V 2500 MM BO600RPOPTION 2500 MM Conseils d utilisation Le bandeau s installe sur des portes en tirant et affleurantes un ou deux vantaux service semi fixe Il se pose sur des portes parfaitement align es dans le cas contraire il faut pr voir une cale R f REO Vous pouvez galement renforcer votre porte avec le profil renfort Ref PRP800 et cacher votre installation lectrique avec le passe c ble Ref ALMA Rappel Les ventouses sont d j mont es sur le support mural La poign e bandeau est quip e en s rie des contreplaq
7. and dimensions techniques et dimensions peuvent varier et sont susceptibles de modifications sans notification pr alable h could be perceptibly different and can be changed without prior notice Toutes les informations mentionn es titre indicatif sur le All tHe information cont CDVI SWEDEN SWEDEN DANEMARK NORWAY FINLAND Phone 46 0 31 760 19 30 Fax 46 0 31 748 09 30 CDVI UK UNITED KINGDOM IRELAND Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86
8. ensemble Fermez la porte v rifiez que les ventouses sont bien positionn es face leur contreplaques puis fixez d finiti vement la poign e bandeau Coupez le cache vis en deux parties distinctes de mani re pouvoir ins rer la poign e encombrement environ 250 mm V rifiez que la poign e est situ e une hauteur accaptable du sol pour en faciliter l usage Pr senter les cache vis et les clipser dans le profil puis placez la poign e Pour garantir la bonne tenue de la poign e dans le temps il est imp ratif de fixer la poign e avec les deux vis fournies cet effet cdvi com cdvigroup com 9 Montage N 1 Bouton poussoir int rieur Carte TPV en option BO600RP eee eevee eee De 1 a 3 ventouse 300 kg 12Vdc 24Vdc Bouton poussoir selon mod le NO NF 44 int rieur RP EE SE PE eS el i i VENTOUSE N 1 UL 0 Alimentation 12 V ou 24 V DC J KEA Nr E Commande temporis e par TPV Important Lorsque la ventouse est quip e d un bornier il est imp ratif d enlever les deux cavaliers du TPV R glage de la temporisation de 0 a 20 secondes Ois Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC Alimentation 12 V DC ou 24 V DC En fonction du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC Bornier 5 points ventouse 12 V DC 24 V
9. i e _ i ARD212 BS602 PATENTED EBREVETE INSTALLATION MANUAL BO600RP Vertical retrofit housing Product Details BO6OORP 2500MM Power Considerations The handle is designed to house electromagnets with a holding force of 300Kg each These units can be supplied by either 12Vdc or 24Vdc depending upon your preferred choice 48v supplied on special request The current required depends on the amount of electromagnetic locks and the voltage chosen please see Technical Specification and ensure you have allocated sufficient power to BO600RP 2500mm housing with 2 magnetic locks would require PSU12 2 or ARD2 12 at 12Vdc PSU24 1 or ARD24 at 24Vdc General Advice The 2 parts of the architectural housing are designed to be surface mounted on the door and frame where they should be parallel when the door is closed If there is a rebate then it will be necessary to pack out the lower part to be parallel to the other Aluminium rail spacer Ref REO You can also use the PRP800 BO600RPSTD 2190MM BO600RPOPTION 2500MM BOGOORPS3SV 2500MM Reinforcement section or ALMA Aluminium Cable tray to reinforce the housing mounting Wiring Plan your cable routes before commencing installation We recommend a maximum distance of 10m from the power supply to the electromagnetic locks to prevent volt drop If the distance is greater then make sure you have increased the cross section of the cable to compensate Inf
10. ns cdvi com 6 cdvigroup com MANUEL D INSTALLATION BO600RP Bandeau architectural vertical Merci pour l achat de ce produit et pour la confiance que vous accordez a notre entreprise 1 PRESENTATION DU PRODUIT u NF S 61 937 mw Existe en versions Standard Herm tique Avec poign e m Esth tique a Installation sur tout type de porte huisserie m tallique bois et verre m Id al pour les r novations m Profils pr perc s r glables x Ventouses avec bornier de raccordement pr install es sur le poteau technique x Largeur recouvrant les anciennes installations m Passage des c bles facilit grace au bossage central l arri re du poteau technique support des ventouses Capot de recouvrement du poteau technique apr s montage Options Rehausses en aluminium moulures en aluminium pose sur porte en verre R f UBK25 teinte RAL coupe Force du bandeau 2 x 300 kg a Dimensions L x I x P BO600RPSTD 2190 x 105 x 63 mm BO600RP 2500 x 105 x 63 mm Poteau technique sur le dormant pr vu pour l installation des ventouses et poi gn es bandeaux avec contre plaques sur l ouvrant Alimentation 12 24 48 DC Consommation 12 V DC 550 mA par ventouses 24 V DC 275 mA par ventouses 48 V DC 275 mA pour les 2 ventouses T LN l DORMANT OUVRANT j i ALMA o p H R N HAUTE R SISTANCE R D
11. ormation The electromagnets are pre fitted within the lock section The armature plates are pre fitted within the architectural handle Both sections are supplied with end caps Handle You must secure the handle with the 2 screws which comes with the retrofit housing 3 PACKAGE CONTENTS Profiled handle Profiled handle Box section Box section es End caps Handle with end caps fixings cover back plate cover BO60ORP 2500 mm 1 1 1 1 2 1 BOG60ORPSTD 2190 mm 1 1 1 1 2 1 BOGOORP3V 2500 mm 1 1 1 1 2 1 cdvi com cdvigroup com Position the box section backplate complete with pre fitted electro magnetic locks on to the door frame or fixed door leaf if installing onto double doors ensure the positioning will allow for the architectural handle to close securely over the section Once you are satisfied with the position mark the vertical and horizontal holes then drill as required Take note of the cable entry holes and feed the cables through Fix the section into place then wire the electromagnetic locks in accordance with the wiring schematic in Section 5 Fit the box section cover into place fit the end caps and secure with the M4 screws provided To finalise the assembly tighten all fixings and protect the handle fixing section by fitting the cover and end caps cdvi com 4 cdvigroup com With the door closed position the architectural handle onto the edge of
12. the opening leaf of the door ensuring the handle covers the box section Mark the vertical and horizontal holes drill as required then temporarily fix the handle leaving a small gap around the box section check the alignment of the magnets in the box section with the armatures in the handle Adjust if necessary then once satisfied secure the handle by completing the fixings Cut the top cover unit into 2 pieces Double check the length of each section of top cover before final cutting Take into account the plastic handle 215MM Ensure the plastic handle is at optimum position for users then make the final cuts to the covers Insert the end caps and secure Insert the plastic handle and clip it into position Secure the handle with the 2 screws ALLATION MANUAL BO6GOORP i Vertical retrofit housing 5 WIRING SCHEMATIC Example N 1 Exit button only VHLD timer optional BO6OORP RANGE From 1 to 3 magnetic PU locks depending on model 12Vdc 24Vdc Button pertoneninensnvantnvetanensmaneonnsivens HH Q l Electromagnetic lock ll O l i Voltage 12Vdc or 24Vdc i Electromagnetic lock g Ppa 1 5 Way Terminal Strip non monitored version 12Vdc or 24Vdc positive 12Vdc or 24Vdc negative Voltage 12Vdc or 24Vdc Place the jumpers to select 12Vdc or 24Vdc supply to your magnetic locks 5 Way Terminal
13. ues et des bouchons chaque extr mit Handle Vous devez imp rativement fixer la poign e plastique avec les deux vis d di es fournies avec le produit BO600RP 2500 mm BO600RPSTD 2190 mm BOG6GO0ORP3V 2500 mm cdvi com 8 cdvigroup com MANUEL D INSTALLATION BO600RP Bandeau architectural vertical 4 MONTAGE Positionnez le support mural avec ses ventouses sur le fixe ou semi fixe Prenez les marques dans les trous oblongs horizontaux et verticaux et percez la surface du vantail au niveau des marques Pr voyez les sorties des cables grace au bossage central l arri re du support mural et en vous aidant du sch ma de c blage des ventouses page suivante Vissez le support mural et fixez les bouchons chaque extr mit du profil l aide des vis auto taraudeuses t te bomb e M4 fournies Positionnez le capot sur le support mural et emboitez le dans son logement Pour le ban deau m me proc dure instal lez le cache vis dans sa charni re et emboitez le dans son logement Positionnez la poign e bandeau munie de ses contreplaques sur l ouvrant Prenez les marques dans les trous oblongs horizon taux et verticaux pour fixer la poign e bandeau Percer la sur face de la porte au niveau des marques r alis es Placez et vis sez provisoirement la poign e afin de laisser un l ger espace qui vous permettra d effectuer le r glage final de l
14. une responsabilit concernant les dommages sur les biens ou les personnes Un produit reconnu d fectueux par CDVI doit tre retourn au service apr s vente de CDVI apr s l obtention du num ro d autorisation de Retour de Produit s D fectueux RMA La responsabilit de CDVI se limite la r paration ou au remplacement d un produit ou pi ces d fectueuses en ses ateliers L une ou l autre de ces interventions sont d finis par le service apr s vente de CDVI Le pr judice imputable CDVI ne saurait en aucun cas d passer la valeur du produit La responsabilit de CDVI ne peut tre engag e aupr s de l acheteur installateur client final ou qui que ce soit lors de dommages cons cutifs des imperfections ou mauvais fonctionnement du produit Cette garantie prend effet la date d enregistrement du produit aupr s de CDVI partir de l instant ou la date d enregistrement est d ment compl t e dans la limite d un mois apr s la date de livraison au client final Pour obtenir les d tails complets de cette garantie et enregistrer votre vos produit s pour b n ficier de cette Garantie Vie limit e Veuillez compl ter la carte d enregistrement pr sente dans la boite du produit et nous la retourner par email ou par courrier l adresse de l entit CDVI la plus proche ou vous enregistrer en ligne l adresse www cdvigroup com Les contacts des entit s CDVI sont accessibles en ligne l adresse www cdvigroup com ou