1.    6  When the contact time is completed  drain the tank  Refill with potable water  and purge the plumbing of all sanitizing solution     TROUBLESHOOTING    WINTERIZINGIf water is allowed to freeze in the system  serious damage to   the plumbing and the pump may occur  Failures of this type will void the   warranty  The best guarantee against damage is to completely drain the water  system    NOTE  When used per the manufacturers recommendations non toxic antifreeze  for potable water is safe for use with SHURflo pumps  Refer to the  coach manufacturer and other equipment manufactures for their  specific winterizing  amp  drainage instructions    CAUTION  Do not use Automotive Antifreeze to winterize potable  water systems  Such solutions are highly toxic  Ingestion may cause  serious injury or death    To properly drain the system perform the following    1  Drain the water tank  If the tank doesn t have a drain valve  open all faucets   allowing the pump to operate  15 min  ON   15 min  OFF  until the tank is empty    2  Open all the faucets  including the lowest valve or drain in the plumbing  and allow  the pump to purge the water from the plumbing  then turn the pump OFF    3  Using a pan to catch the remaining water  remove the plumbing at the pump s  inlet outlet ports  Turn the pump ON  allowing it to operate until the water is  expelled  Turn OFF power to the pump once the plumbing is emptied  Do not  reconnect pump plumbing  Make a note at tank filler as a reminder
2.    La taille du fil  calibre Mm    est fonction de la distance   entre la source de courant et la pompe  Il est conseill     d utiliser du fil n  14  2 5 mm      Pour des longueurs de 20      50 pieds  6   15 M  utiliser du fil n  12  4 Mm          L   appel total de courant dans le circuit ne doit pas d  passer  15 amp  res  Si la pompe est utilis  e avec d   autres  composants  une protection de surcharge de courant   fusible ou coupe circuit  et la taille du fil doivent  correspondre aux exigences totales d   amp  res pour tous  les appareils du circuit   lectrique     FLEXIBLE TRESSE DE HAUTE PRESSION           13 MM DE D I  LONGUEUR 30 CM   recommand        lt  COLLIERS EN ACIER    a INOXYDABLE     2 OBLIG                  NC CR  PINE DROITE  maille 50     RACCORDS CANNEL  S PIVOTANTS     mastic non n  cessaire  Ne pas trop serrer     RACCORD  gt      tanche           Inclus dans les kits de pompe vendus dans le commer    PLOMBERIE    e SHURflo conseille d   utiliser un tuyau flexible haute  pression de 1 pied  0 3 m  et de 0 5 pouce  13 mm  de  diam  tre interne pour les deux orifices  Dans l   id  al  les  orifices cr  pines de la pompe ne doivent pas   tre  raccord  s    des tuyaux rigides ou en plastique   L   oscillation naturelle de la pompe peut se transmettre  par l   interm  diaire de tuyaux rigides  ce qui entra  ne du  bruit  et peut m  me d  tacher ou fissurer des composants    e Il est conseill   d   installer une cr  pine de maille 50 afin  d emp  cher les 
3.    Plumbing is  Disconnected     4  All faucets must be left open to guard against any damage     Vibration induced by road condition can cause plumbing or pump hardware to loosen  Check for system components that are loose  Many symptoms can be resolved by  simply tightening the hardware  Check the following items along with other particulars of your system     PUMP WILL NOT START  BLOWS CIRCUIT       Electrical connections  fuse or breaker  main switch  and ground connection       Is the motor hot  Thermal breaker may have triggered  it will reset when cool       Is voltage present at the switch  Bypass the pressure switch  Does the pump  operate       Charging System for correct voltage   10   and good ground    Y For an open or grounded circuit  or motor  or improperly sized wire    Y For seized or locked diaphragm assembly  water frozen        WILL NOT PRIME SPUTTERS   No discharge Motor runs       Is the strainer clogged with debris    v Is there water in the tank  or has air collected in the hot water heater    v Is the inlet tubing plumbing sucking in air at plumbing connections  vacuum leak        Is inlet outlet plumbing severely restricted or kinked    y Proper voltage with the pump operating   10      Y For debris in pump inlet outlet valves or swollen dry valves    Y Pump housing for cracks or loose drive assembly screws     SERVICE KITS   To insure the correct service kit  order by the complete model number  date of  manufacture and other name plate data  Part k
4.  gt  SHURHIO    POTABLE WATER PUMP    Installation and Operation Manual    SHURflo has supplied pumps to the manufacturers of RV s for over  30 years  Our patented Tri a fram   line of potable water pumps  deliver smooth  consistent flow at all ranges of operation  while  drawing low current  The balanced diaphragm design incorporates  SHURflo pumps are  100  tested for proper operation before they leave the factory  When  installed correctly  SHURflo water pumps will provide years of quiet    two precision ball bearings for long life     operation     A SHURflo pump in combination with a low back pressure water l A  system can exceed all expectations  For unmatched reliability and x  trouble free performance request SHURflo s complete line of water    system products     GENERAL INFORMATION             FUSE     _          SWITtH     A          SHUT OFF   DRAIN VALVE    1 2  BARB IN LINE MODELS     Typical potable water system shown with optional SHURflo accessories      FF    N  e N    l 1        FILTERED WATER  x FAUCET                                                                                        J    WATER PRESSURE  REGULATOR  IN LINE FAUCET          TWIST LOCK STRAINER      ADAPTER    1 2  THREADED OR OR       WALL MOUNT MODEL     SHURflo realizes that in many instances our pump is being installed as a replacement pump within an existing system   The following guidelines should be considered to achieve optimum pump operation    MOUNTING    _ The pump can be at th
5.  les autres particularit  s de votre r  seau     LA POMPE NE SE MET PAS EN MARCHE   COURT CIRCUITE    v Raccords   lectriques  fusible ou interrupteur  interrupteur principal  et raccord de terre    Y Le moteur est il chaud  L   interrupteur thermique a pu se mettre en marche  il se r     enclenche une fois le moteur refroidi       L   interrupteur fait il passer du courant  Contourner l interrupteur de pression  La pompe  se met elle en marche    v Voltage ad  quat   10   et une bonne mise    terre du circuit   lectrique    v V  rifier le circuit ouvert ou de terre  le moteur   existe t il un fil de la mauvaise taille       L   assemblage du diaphragme est il gripp   ou bloqu    eau gel  e      NE S   AMORCE PAS   CRACHE   Pas de refoulement   le moteur fonctionne    v La cr  pine est elle encombr  e de d  bris    v Y a t il de l   eau dans le r  servoir  ou de l   air dans le chauffe eau    v La plomberie d   arriv  e aspire t elle de l   air au niveau des raccords  manque d   tanch  it          La plomberie d   arriv  e   de sortie est elle encombr  e ou entortill  e    v Voltage correct lorsque la pompe fonctionne   10      v Y a t il des d  bris dans la pompe  dans les valves d   arriv  e   de sortie  Les valves sont   elles gonfl  es   s  ches    v Y a t il des fissures dans le carter de la pompe  Les vis du m  canisme d   entra  nement  sont elles desserr  es     KITS DE SERVICE    Pour obtenir le bon kit de service  commander avec le num  ro complet de mod  le  la dat
6.  litres que peut contenir le r  servoir    par 1  le r  sultat est  exprim   en millilitres d   eau de Javel n  cessaires pour nettoyer le r  servoir    2  M  langer    la solution la dose correcte d   eau de Javel dans un r  cipient d   eau    3  Mettre la solution  eau Javel  dans le r  servoir et remplir le r  servoir d   eau potable    4  Ouvrir tous les robinets  le chaud et le froid   ce qui permet    l   eau de s     couler  jusqu      ce que l   on distingue l   odeur de Javel    5  La solution standard doit agir pendant quatre  4  heures afin de d  sinfecter compl  tement   En doublant la solution  on peut laisser agir seulement pendant une  1  heure    6  Une fois le temps   coul    vidanger le r  servoir  Remplir d   eau potable et vidanger  toute la plomberie de la solution nettoyante     EN CAS DE PROBL  MES    PREPARATION POUR L HIVER   Laisser l   eau geler dans le r  seau peut endommager la plomberie et la pompe  Des d  g  ts de   ce type ne sont pas couverts par la garantie  La meilleure garantie contre de tels d  g  ts est   de vidanger compl  tement le r  seau d   eau    NOTE  Lorsqu il est utilis   suivant les instructions du fabricant un antigel non toxique  pour eau potable est sans danger pour les pompes SHURflo  Se reporter aux  instructions de vidange et de pr  paration pour l   hiver du constructeur  automobile et des autres fabricants de mat  riel    ATTENTION  Ne pas utiliser d   antigel automobile pour pr  parer les r  seaux d   eau  potable pour 
7. HURflo  Les pannes provo   qu  es par des d  bris   trangers ne sont pas couvertes par les termes de cette garantie limit  e   SHURflo ne garantira aucune pompe physiquement endommag  e ou alt  r  e    l   ext  rieur de l   usine  SHURflo    Les r  clamations de garantie peuvent   tre r  solues aupr  s du service apr  s vente d   un revendeur agr      ou  par SHURflo  Les appareils doivent   tre renvoy  s aux frais de l   exp  diteur  Emballer soigneusement les  appareils retourn  s  SHURflo ne pourra   tre tenu responsable des d  g  ts encourus pendant le transport vers  un centre de service apr  s vente    Pour le d  tail limit   complet de garantie consultez le bulletin de service    1050     D SHURTlo    Pentair Water       SHURflo se r  serve le droit de mettre    jour les sp  cifications et prix ou d   effectuer des substitutions sans pr  avis   SHURflo  LLC   SHURflo  LLC East SHURflo Ltd   5900 Katella Ave  52748 Park Six Court Unit 5 Sterling Park  Cypress  CA 90630 Elkhart  IN 46514 5427 Gatwick Road  Crawley   800  854 3218  562  795 5200  800  762 8094  574  262 0478 West Sussex  RH10 2QT  FAX  562  795 7564 FAX  574  264 2169 United Kingdom  Livraison UPS  5900 Katella Ave  Bldg  http   www shurflo com  44 1293 424000  c    1999 2005 Printed in USA FAX 4441293421880    Cypress  CA 90630  pg  2 of 2    
8. OURNANK    Z  ROBINET D EAU    FILTREE                                                                          R  GULATEUR DE      PRESSION D EAU  ADAPTATEUR DE    MOD  LES DROITS    RACCORD FILET     ROBINET DROIT  DE 13 MM OU    RACCORD CANNEL     _ OU  DE 13 MM      MOD  LES MURAUX     R  seau typique d eau potable montr   avec les accessoires en option  SHURflo     SHURflo sait que dans la plupart des cas ses pompes sont install  es en tant que pompes de remplacement    l   int  rieur d   un r  seau existant  Les directives suivantes doivent    tre prises en compte afin d   obtenir un fonctionnement optimal des pompes     MONTAGE    e La pompe peut se trouver au m  me niveau ou en  dessous du r  servoir    eau  Si n  cessaire  elle peut se  trouver au dessus du r  servoir    eau  puisqu elle  poss  de une capacit   d   amor  age vertical de 6 pieds   1 8 M   Un tuyau d   arriv  e horizontal permettra un  amor  age de 30 pieds  9 m     Installer de pr  f  rence dans un lieu facile d   acc  s en cas  d entretien  La pompe ne doit pas se trouver dans une  zone de moins de un pied cube sauf en cas de ventilation  ad  quate  Une chaleur excessive peut mettre en marche  l interrupteur thermique int  gr   et arr  ter la pompe  Lors  d   une chute de temp  rature  l   interrupteur se mettra en  marche automatiquement pour la red  marrer    La pompe peut   tre install  e dans n   importe quelle  position  Si la pompe est install  e verticalement  elle  doit   tre t  te en bas  ca
9. d  bris   trangers de p  n  trer dans la  pompe      Les raccords cannel  s pivotants SHURflo permettent un  d  bo  tement facile en cas d   entretien ou d   acc  s  Les  raccords comprennent un   joint conique    qui assure un  raccord   tanche lorsqu il est serr      la main  N utiliser  Jamais du ruban T  flon ou du mastic sur les fils  Le mastic  peut p  n  trer    l   int  rieur de la pompe  ce qui provoquerait  une panne  Les pannes provoqu  es par Ventr  e de d  bris    trangers ne sont pas couvertes par la garantie  Fixer  toujours les raccords cannel  s    l   aide de colliers de la  bonne taille et en acier inoxydable afin d   viter les fuites    e Un retour de pression excessif  r  sultant de l   un des    l  ments suivants    l   int  rieur de la plomberie  peut  provoquer un cycle rapide        Les filtres    eau et les purificateurs ne sont pas sur  des lignes d   alimentation s  par  es        Restrictions de flux    l   int  rieur des robinets et des  t  tes de douche        Ligne    petit diam  tre int  rieur  Le diam  tre interne des  tuyaux doit   tre au minimum de 0 5 pouce  13 mm  pour  les lignes principales        Raccords cr  ant des restrictions  coudes  raccords   en T     lignes d   alimentation vers les robinets  etc      INTERRUPTEUR D   ARRET    Les restrictions    l   int  rieur de la plomberie peuvent  provo quer un cycle rapide de la pompe  MAR  ARR  en 2  secon des  en cas de faible flux  Le cycle doit   tre  minimis   afin d   emp  cher les 
10. e   If cycling cannot be minimized consider  removing plumbing restrictions or simply install a  SHURflo Accumulator     911 352 Rev  I 06 05 pg    of 2    SANITIZING   Potable water systems require periodic maintenance to deliver a consistent flow of  fresh water  Depending on use and the environment the system is subject to   sanitizing is recommended prior to storing and before using the water system after  a period of storage  Systems with new components  or ones that have been  subjected to contamination  should also be disinfected as follows    NOTE  The sanitizing procedure is in conformance with the approved procedures   of RVIA ANSI A119 2 and the U S  Public Health Service   1  Use one of the following methods to determine the amount of common household  bleach needed to sanitize the tank     A  Multiply  gallons of tank capacity  by 0 13  the result is the ounces of bleach  needed to sanitize the tank     B  Multiply  Liters of tank capacity  by 1 0  the result is the milliliters of  bleach needed to sanitize the tank    2  Mix into solution the proper amount of bleach within a container of water    3  Pour the solution  water bleach  into the tank and fill the tank with potable water    4  Open all faucets  Hot amp Cold  allowing the water to run until the distinct odor of  chlorine is detected    5  The standard solution must have four  4  hours of contact time to disinfect  completely  Doubling the solution concentration allows for contact time of one   1  hour 
11. e  Bldg  C  Cypress  CA 90630    SHURflo Ltd   Unit 5 Sterling Park  Gatwick Road  Crawley  West Sussex  RH10 2QT  United Kingdom   44 1293 424000  FAX  44 1293 421880    Elkhart  IN 46514 5427   800  762 8094  574  262 0478  FAX  574  264 2169  hitp   www shurflo com     1999 2005 Printed in USA    pg  2 of 2    D SHURHIO    Pentair Water    POMPE A EAU POTABLE    Manuel d installation et d   utilisation    SHURflo fournit des pompes aux fabricants de caravanes depuis plus de 30    ans  Notre ligne brevet  e Tri a fram   de pompes    eau potable fournissent  un flux sans    coups  r  gulier    tous les niveaux du fonctionnement  avec un  faible besoin en courant   lectrique  Leur conception    diaphragme   quilibr    comprend deux roulements    bille de pr  cision extr  mement durables  Les  pompes SHURflo sont test  es    700  pour assurer qu   elles fonctionnent  Install  es correctement  les NN a  pompes    eau SHURflo fourniront des ann  es de service sans histoires  1    correctement avant leur d  part de lusine     Une pompe SHURflo utilis  e dans un r  seau d   eau    faible retour de  Si vous recherchez une  fiabilit   et une performance    toute   preuve  demandez la gamme compl  te    pression peut d  passer toutes les esp  rances     des produits de r  seaux d   eau SHURflo   INFORMATION G  N  RAL                             POMPE    SHURflo     lt  VENTILATION            RESERVOIR D EAU          cn    VALVE D ARR  T DE   VIDANGE         CR  PINE    VERROUILLAGE T
12. e  de fabrication et autres donn  es figurant sur la plaque du fabricant  Les pi  ces du kit sont  livr  es avec des instructions de r  paration compl  tes  Les sch  mas de pompe ne  repr  sentent peut   tre pas exactement toutes les pompes    eau potable SHURflo  mais ils  sont l   pour repr  senter les assemblages des diverses pi  ces du kit           1 Interrupteur   clapet anti retour et kit du carter sup  rieur   Remplace tous les interrupteurs pr  c  dents    Assemblage de la plaque de la valve   Diaphragme   m  canisme d entra  nement   Moteur   Ensemble t  te de pompe  comprend les pi  ces n  1  2  3    Remplace tous les interrupteurs pr  c  dents                 Uy D  Ge  bo                 911 352 Rev  I 06 05    LA POMPE NE S   TEINT PAS FONCTIONNE LORSQUE LE ROBINET EST FERM      v Fuites dans la plomberie du c  t   de la sortie  pression   V  rifier si les valves ou les toilettes  fuient    VY a t il de l   air emprisonn   du c  t   de la sortie  chauffe eau  ou de la t  te de pompe    V Le voltage d   alimentation est il correct   10      V Les vis du m  canisme d   entrainement ou de la t  te de pompe sont elles desserr  es       Les valves ou les clapets anti retour demeurent ils ouverts    cause de d  bris ou bien le  caoutchouc est il gonfl       V Le fonctionnement l   ajustage de l interrupteur de pression est incorrect  se reporter     l   ajustage du seuil d   arr  t pour l interrupteur    TROP DE BRUIT OU MAUVAIS FONCTIONNEMENT        La plomberie s   e
13. e same level or below the  water tank  It may be positioned above the water  tank if needed  as it is capable of a 6 ft   1 8M   vertical prime  Horizontal inlet tubing will allow  priming to 30 ft   9M     _ Consider a location that allows easy access if  maintenance is required  The pump should not be  located in an area less than one cubic foot unless  adequate ventilation is provided  Excessive heat  may trigger the integral thermal breaker and  interrupt operation  When the temperature drops  the breaker will automatically reset and start  operation    _ The pump may be mounted in any position  If mounting  the pump vertically  the pump head should be in the down  position so that in the unlikely event of a leak  water  will not enter the motor    _ Use  8 hardware to fasten the pump  Choose a solid  surface  thick plywood  that will not amplify pump  operation  The mounting feet are intended to isolate  the pump from the mounting surface  over   tightening  flattening  or use of oversized screws    1          COACHFRAME OR     KNOWN GROUND     MOUNT TO A SOLID SURFACE      WITH  8 HARDWARE   LAN    v FUSE     See motor label for the    recommended amp fuse      Batt  _    Ba       Pip          ELECTRICAL    _The pump should be on a dedicated  individual   circuit  protected by the specified fuse indicated on  the motor label    _A switch rated at or above 15 amps is  recommended  and must interrupt current flow on  the positive    red  lead  Marine applications should  
14. from  entering the pump    _SHURflo swivel barb fittings provide easy removal  if maintenance or access is required  The fittings are  designed with a  taper seal   creating a water tight  connection when hand tightened  Never use Teflon  tape or sealing compounds on threads  Sealer may  enter the pump causing a failure  Failure due to  foreign debris is not covered under warranty   Always secure barb tubing connections with  properly sized stainless steel clamps to prevent  leaks    _ Rapid cycling may be caused by excessive back  pressure created by one or more of the following  within a plumbing system    Water filters not on separate feed lines    Flow restrictors in faucets and shower heads   Small I D  lines  Pipe tubing should be at least _   13mm  I D  for main lines    Restrictive fittings and connections  elbows   T s    feeder lines to faucets  etc      SWITCH SHUT OFF   Restrictions in a plumbing system may cause the  pump to rapid cycle  ON OFF within 2 sec   during low  flow demands  Cycling should be minimized to  prevent pulsating flow  and to achieve maximum  pump life        To determine if adjustment is necessary  turn a faucet  ON to lower than average flow of water  The pump  should cycle  but its  OFF time  must be 2 sec  or      longer  If the cycling is correct  leave well enough    alone  If the pump is cycling rapidly increase the  setting by turning the screw clockwise  1_ turn MAX    until the pump operates for 1 sec  with at least 2 sec    OFF tim
15. its come with complete repair  instructions  Pump illustrations may not be representative of all SHURflo potable    water pump models and are only for depiction of the various parts kit assemblies   1 Switch   Check valve and Upper Housing Kit     Replaces all previous switch designs           2 Valve plate assembly  3 Diaphragm   Drive assembly  4  5          Motor  Complete Pump Head assembly  includes parts    1  2  3    Replaces all previous switch designs                    911 352 Rev  I 06 05       PUMP WILL NOT SHUT OFF   RUNS WHEN FAUCET IS CLOSED       Output side  pressure  plumbing for leaks  and inspect for leaky valves or toilet      For air trapped in outlet side  water heater  or pump head       For correct voltage to pump   10         For loose drive assembly or pump head screws       Are the valves or internal check valve held open by debris or is rubber swollen      Pressure switch operation adjustment  refer to shut off adjustment for switch   NOISY OR ROUGH OPERATION    Y For plumbing which may have vibrated loose    v Is the pump plumbed with rigid pipe causing noise to transmit       Does the mounting surface multiply noise  flexible        For mounting feet that are loose or are compressed too tight       For loose pump head to motor screws   3 long screws    y The motor with pump head removed  Is noise from motor or pump head   RAPID CYCLING       For restrictive plumbing  flow restrictors in faucets shower heads    v Water filter purifier should be o
16. l   hiver  De tels produits sont extr  mement toxiques  Leur  ingestion peut provoquer de graves blessures et m  me la mort    Afin de vidanger le r  seau correctement  suivre les   tapes suivantes    1  Vidanger le r  servoir    eau  Si le r  servoir ne poss  de pas de valve de vidange  ouvrir  tous les robinets et d  marrer ainsi la pompe  15 min  MARCHE   15 min  ARRET   jusqu   a ce que le r  servoir soit vide    2  Ouvrir tous les robinets  y compris la valve ou la vidange la plus basse    l   int  rieur de la  plomberie  et laisser la pompe vidanger l   eau de la plomberie  puis mettre la pompe  sur ARR  T    3  Tout en utilisant une bassine pour recueillir l   eau restante  d  connecter la plomberie des  orifices d   arriv  e de sortie de la pompe  Mettre la pompe sur MARCHE  ce qui permet     la pompe de fonctionner jusqu      ce que l   eau soit expuls  e  Mettre le courant vers la  pompe sur ARR  T une fois que la plomberie est vide  Ne pas reconnecter la plomberie de  la pompe  Ecrire une note sur la bouche du r  servoir pour m  moire     La plomberie  est d  connect  e       4 Tous les robinets doivent   tre laiss  s ouverts afin de pr  venir les d  g  ts     Les vibrations provoqu  es par la conduite peuvent d  tacher la plomberie ou les fixations de la pompe  V  rifier que tous les   l  ments du r  seau sont bien attach  s  De nombreux sympt  mes peuvent    tre solutionn  s en resserrant tout simplement les fixations  V  rifier les   l  ments suivants  ainsi que
17. n separate feed line       Pressure switch shut off adjustment    LEAKS FROM PUMP HEAD OR SWITCH    Y For loose screws at switch or pump head    v Switch diaphragm ruptured or pinched    Y For punctured diaphragm if water is present in the drive assembly     LIMITED WARRANTY    SHURflo warrants its Potable Water pumps to be free from material and workmanship defects under  normal use and service for a period of two  2  years from the date of manufacture indicated on the  motor name plate    The limited warranty will not apply to pumps that were improperly installed  misapplied  or are  incompatible with components not manufactured by SHURflo  Pump failure due to foreign debris is  not covered under the terms of this limited warranty  SHURflo will not warrant any pump that is  physically damaged  or altered outside the SHURflo factory    Warranty claims may be resolved by an authorized dealer service center  or by a SHURflo service center   Returns are to be shipped with charges pre paid  Package all returns carefully  SHURflo will not be  responsible for freight damage incurred during shipping to a service center    For complete Limited Warranty details consult Service Bulletin    1050       SHURTlo    Pentair Water    SHURflo reserves the right to update specifications  prices  or make substitutions    SHURflo  LLC   SHURflo  LLC East  5900 Katella Ave  52748 Park Six Court  Cypress  CA 90630   800  854 3218  562  795 5200   FAX  562  795 7564   Shipping UPS  5900 Katella Av
18. pulsations de flux  et  d   assurer une longue dur  e de vie    la pompe    Pour d  terminer si un ajustage est n  cessaire  OUVRIR le  robinet sur un flux d   eau plus bas que la moyenne  La  pompe devrait se mettre    cycler  mais son   temps  D   ARRET gt    doit   tre au minimum de 2 secondes  Si le cycle  n   est pas correct  ne faites rien  Si la pompe cycle  rapidement  augmenter le r  glage en tournant la vis dans le  sens des aiguilles d   une montre  1 5 tour max   jusqu      ce  que la pompe fonctionne 1 seconde pour un minimum de 2  secondes de   temps D   ARRET    Si le cycle ne peut pas   tre  r  duit  envisager de retirer les restrictions de la plomberie  ou d installer tout simple ment un accumulateur SHURflo     911 352 Rev  I 06 05 pg    of 2    NETTOYAGE   Les r  seaux    eau potable ont besoin d   un entretien r  gulier afin de fournir un flux   r  gulier d   eau fra  che  En fonction de l   utilisation et de l   environnement du r  seau  il   est conseill   de le nettoyer avant de le ranger ou de l   utiliser apr  s l   avoir rang   pendant   un certain temps  Les r  seaux poss  dant de nouveaux composants  ou ceux qui ont   t     contamin  s  doivent   galement   tre d  sinfect  s comme ceci    NOTE  Le nettoyage d  crit est en conformit   avec les proc  dures homologu  es RVIA   ANSI A119 2 et le D  partement am  ricain de Sant   publique    1  D  terminer la quantit   d   eau de Javel n  cessaire pour nettoyer le r  servoir   Multiplier    le nombre de
19. r ainsi  en cas improbable de  fuite  l   eau ne p  n  trera pas dans le moteur    Utiliser des fixations n  8 pour installer la pompe   Choisir une surface solide  contre plaqu     pais  qui ne  transmettra pas les vibrations de la pompe  Les pieds de  montage ont pour but d   isoler la pompe de la surface de  montage   le fait de trop serrer  d     craser ou d   utiliser  des vis trop grandes risque de r  duire la possibilit    d   isoler les vibrations   les bruits          CHASSIS DU V  HICULE OU    MISE    TERRE    SURE                MONTER SUR UNE SURFACE  SOLIDE AVEC DES FIXATIONS N  8    SAL   SRA        FUSIBLE AMAA     voir l   tiquette du moteur pour   S      l intensit   de fusible recommand       Y                 fi             Batt      Aa         ve ste  INTER de    lt     ENTREE D EAU    7 POTABLE  FIL DE CALIBRE N   14         2 5 Mm  DU PLUS EPAIS          EL  CTRICIT        La pompe doit   tre install  e sur sa propre ligne de  courant  individuelle   prot  g  e par le fusible indiqu   sur  l     tiquette du moteur      Un interrupteur d   au moins 15 amp  res est conseill    et il  doit interrompre le flux de courant sur le conducteur  positif  rouge   Pour des applications marines  utiliser  des interrupteurs et des pompes homologu  es U L pour  usage marin  allumage prot  g         La pompe doit   tre raccord  e    une mise    terre    s  re       ch  ssis du v  hicule   Le fil de terre doit   tre de la m  me   taille  calibre Mm    que le fil positif 
20. st elle d  tach  e en vibrant     v La pompe est elle raccord  e    un tuyau rigide  ce qui aurait pour effet de transmettre le  bruit       La surface de montage amplifie t elle le bruit  flexible        Les pieds de montage sont ils desserr  s ou trop comprim  s       Les vis raccordant la t  te de la pompe au moteur sont elles desserr  es  3 longues vis     v Essayer le moteur sans la t  te de pompe  Le bruit provient il du moteur ou de la t  te de  pompe    CYCLE RAPIDE    v Y a t il des restrictions dans la plomberie  ou au niveau des robinets des t  tes de douche       Le filtre    eau   le purificateur doivent   tre sur des lignes d   alimentation s  par  es    v Ajustage du seuil d   arr  t de l   interrupteur de pression     FUITES DANS LA T  TE DE POMPE OU L   INTERRUPTEUR    Y Les vis de l   interrupteur ou de la t  te de pompe sont elles desserr  es       Le diaphragme de l   interrupteur est il coup   ou pinc         Le diaphragme est trou   s   il y a de l   eau dans le m  canisme d   entrainement    GARANTIE LIMIT  E   SHURflo garantit que les pompes    eau potables sont exemptes de d  faut de mat  riaux ou de  fabrication dans le cadre d   un usage normal pendant une p  riode de deux  2  ans    compter de leur  date de fabrication indiqu  e par la plaque du fabricant sur le moteur       La garantie limit  e ne s   appliquera pas aux pompes incorrectement install  es  utilis  es ou qui sont  incompatibles avec des liquides ou des composants non fabriqu  s par S
21. use U L approved marine duty  ignition protected   switches and pumps    _ Wire size  gauge Mm     is based on the distance  from the power source to the pump  Recommended  size wire is    14 gauge  2 5Mm      For lengths of 20   50ft   6 15M  use    12 gauge  4 Mm        _ The pump must be grounded to a  known ground    frame   The ground wire must be the same size   gauge Mm    as the positive wire    _ The total current draw on the circuit must not exceed  15 amps  If the pump is used in conjunction with  other components  overload current protection  fuse  or circuit breaker  and wire size must be for the total  amp requirement of all devices on the circuit     1 2 1 D  FLEXIBLE BRAIDED  high psi         TUBING 12 in  LENGTHS     recommended     STAINLESS STEEL    CLAMPS  2 REQ      WITCH j     5 es Min   l  lt     POTABLE WATER  gt  SL  P TEN EES j MEEN        SWIVEL BARB FITTINGS    2 5 M GAU CONNECTOR  gt   No Sealer Req  Do Not Overtighten     OR HEAVIER WIRE       Included with retail pump kits      Water proof       S IN LINE STRAINER  50 Mesh     PLUMBING    _SHURflo recommends at least 1ft    3 M  of _    13mm  I D  flexible high pressure tubing to both  ports  Ideally the pumps ports strainer should not  be connected to plastic or rigid pipe  The pump s  normal oscillation may transmit through rigid  plumbing causing noise  and possibly loosen or  crack components    _ Installation of a 50 mesh strainer  SHURflo P N 170   is recommended to prevent foreign debris 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
    Owner`s Manual - Spanish  取扱説明書  Honeywell TE328ELW User's Manual  Ficha Passport - Aerobic & Fitness  Page 1 Page 2 業務用 ア丿~ミを採用することで 総質量を約20%減量し  Tecnoware FGCEVODS10TM/00 uninterruptible power supply (UPS)  使用上の諸注意志摩1409号室  Olimpia Splendid Unico 8.5 HP User Guide Manual AIR    Copyright © All rights reserved. 