1. re 43 1092mm B a SI A 5 lt i A S aaa aaa aaa OO a aaa zo 2 S Lo 5 a CN I T B a TOP VIEW m 38 965mm gt lt 3 5 8 91mm gt 2 9 16 64mm gt o O 10 O D 2 S o 2 R O O IL 1 O O i 9 mm o o M RT T he br i TI L E m ili ss IT y Bes z L E 3 C Z st 11LB TANK 2 11LB TANK S T N 1 m 5 I o Y i nes Y FLOOR LEVE 16 11 16 423mm Flaortahpottom 40 5 8 1030mm 425mm of LP tank SIDE VIEW END VIEW Regency Plateau Foyer gaz ext rieur E DIMENSIONS DU ILOT 30 13 16 782mm 11 7 8 298mm 298mm U i 57 1 2 SE 1461mm a D S S 1 5 8 CIM 3 46 a 156mm C TT a lalaa E OA j 28 718 NN 733mm 20Ib tank 3 4 20lb tank 19mm EEE l Pt i 20 11 16 Kae 1031mm 525mm Floor level Floor to bottom of LP tank EG Regency Plateau Foyer a gaz ext rieur DIMENSIONS DIMENSIONS DU BAR oo 49 5 32 1248mm TOP VIEW 49 5 32 1248mm SIDE VIEW i END VIEW FLOOR LEVEL v M 7 Regency Plateau Foyer a gaz ext rieur E INSTALLATION MESSAGE IMPORTANT CONSERVER PRECIEUSEMENT CES IN
2. o Regency Plateau Foyer a gaz ext rieur REMARQUES Regency Plateau Foyer a gaz ext rieur REMARQUES Regency Plateau Foyer a gaz ext rieur REMARQUES Regency Plateau Foyer a gaz ext rieur REGENCY Regency decorative gas appliance Products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility FPI decorative gas appliance Products International Ltd is pleased to extend this limited warranty to the original purchaser of a Regency Product This warranty is not transferable Limited Warranty The combustion chamber is covered for parts and subsidized labour only against defect in manufacture only for a period of 5 five years from date of purchase The gas valve burner tube pilot assembly flame sensor electrode control modules switches and wiring for battery compartment are all covered for 2 two years on parts and 1 one year on subsidized labor only against defect in manufacture from date of purchase Ceramic logs spa and garden stones glass crystals and tempered glass wind shield carry a 1 one year warranty against manufacturing defect on parts with no labor allowance from date of purchase Specials finishes such as stainless steel components are not covered against environmental damage misuse cleaning or handling issues that cause discoloration To recei
3. Capteur de flamme Faisceau de fils 5 Enlever le bo tier num rique retenu par quatre vis 6 Remplacer par un nouveau bo tier et refaire la proc dure invers e des 2 Enlever les deux vis qui retiennent le couvercle du bo tier de la soupape stapes ar REMPLACEMENT DES PILES 1 Sortir le compartiment de piles sous le boitier de la soupape amenant il 3 D visser les deux vis du bas pour ouvrir le boitier de la soupape et ac c der au boitier de commande num rique compartiment des piles 2 Remplacer les piles et renverser l tape 1 Regency Plateau ES Foyer gaz ext rieur ures Part Description Part Description 376 526 Burner Assembly LP NG 946 775 Fireglass crystals Blk 911 006 Pilot Assembly NG 946 776 Fireglass crystals Copper 911 007 Pilot Assembly LP 946 777 Fireglass crystals Starfire 2 376 574 P Valve Assembly NG 946 778 Fireglass crystals Colbalt Blue 376 574 P Valve Assembly LP Glass crystals in 5lb bags 2 required 911 004 Valve Only NG 6 376 932 Glass Surround 911 005 Valve Only LP 940 374 P Tempered Glass LG 3 904 951 Orifice 25 NG 940 375 P Tempered Glass SM 904 655 Orifice 45 LP 376 027 Glass connectors 376 900 Table top frame 904 952 Nylon fastner 376 902 Tile set Slate 911 012 Ignition Board 376 903 Tile set Brown 326 930 Log Set 376 522 Island riser 919 013 Manual
4. l extr mit oppos e du panneau ou se trouve l interrupteur 2 Enlever le panneau lat ral panneau de gauche si vous faites face au panneau gt Raccorder le r gulateur de PL branchement rapide au r servoir o se trouve l interrupteur pour acc der au raccord de 3 8 po de la com mande de gaz Raccord du gaz au r servoir 3 D visser l crou oreilles pour laisser reposer le r servoir sur le support 7 Avec de l eau savonneuse v rifier la pr sence de fuites dans les entr es de gaz sous pression d utilisation normale soupape d chappement et r servoir de PL ou source de gaz naturel REMARQUE une fuite de gaz produira des bulles de savon Avertissement lorsqu un r servoir de PL est utilis un cart d un moins 1 po doit tre maintenu en tout temps entre la surface et la base du br leur con 4 Placer le r servoir sur le plateau et le fixer solidement en vissant l crou a sulter le manuel du propri taire oreilles Regency Plateau Foyer a gaz ext rieur i RETRAIT DU R SERVOIR DE PL MODELE PTO30IST SEULEMENT 1 Enlever le panneau de bout l extr mit oppos e du panneau ou se trouve 1 Enlever le panneau de bout a l extr mit oppos e du panneau o se trouve l interrupteur l interrupteur 2 Faire glisser le r servoir de PL en tirant la poign e du plateau coulissant 3 D visser l crou oreilles pour laisser reposer le r servoir sur le
5. des tincelles pendant 60 secondes afin d amorcer le GAS APPLIANCE touch Severel 1 Turn on ON OFF switch br leur principal Burns may result 2 After approximately 4 seconds the spark ignition system will spark 3 Les flammes s allumeront i Turn off ON OFF switch Due to high surface Tor 60 seconds to light the main burner Remarque Au premier allumage le syst me tente If service is to be performed temperatures 3 The unit will turn on d allumer les flammes pendant 60 secondes Si l essai est you must disconnect power to keep children infructueux le syst me fait une pause de 35 secondes the unit from the battery pack clothing and Note The first attempt to ignition will last approximately 60 seconds C est ce qu on appelle l tape de rectification Ce d lai refer to manual furniture gasoline If there is no flame ignition rectification the board will stop sparking coul le syst me tente nouveau d allumer les flammes A le bouton ON and other liquids for approximately 35 seconds After this wait time the board will start en produisant des tincelles pendant 60 secondes Si les ppuyez sur le bouton having flammable a second try for ignition by sparking for approximately 60 seconds flammes ne s allument toujours pas le syst me se met OFF vapors away Keep ff there is still no positive ignition after the second attempt the board en mode verrouillage Si le service est effectu e burner and control W
6. gager la veilleuse puis le soulever 6 Remettre l embout 7 R installer le br leur 8 R gler l a ration consulter le manuel pour tous les d tails Orifice de br leur l embout de la veilleuse Regency Plateau Foyer a gaz ext rieur v INSTALLATION 14 Retirer l alimentation en gaz naturel et la remplacer par un r gulateur 9 Retirer le panneau d acc s gauche de l appareil de PL branchement rapide Raccord du gaz au r servoir 15 Avec de l eau savonneuse v rifier la pr sence de fuites dans les entr es de gaz sous pression d utilisation normale soupape d chappement et r servoir de PL ou source de gaz naturel REMARQUE une fuite de gaz produira des bulles de savon 16 Installer le r servoir de PL voir instructions d installation dans ce manuel 17 V rifier la pression d entr e et la pression de sortie 11 Retirer le r gulateur de pression Hi Lo retenu par deux vis tel qu illustr 18 V rifier l intensit des flammes ci dessous Refaire cette proc dure en sens inverse pour installer le r gulateur de pression du PL 12 Apposer l autocollant Converti au propane liquide c t ou au dessus du num ro de s rie 13 Remplacer l tiquette jaune Gaz naturel par l tiquette rouge Propane liquide Regency Plateau Foyer gaz ext rieur INSTALLATION DU RESERVOIR DE PL MOD LE PTO30CFT SEULEMENT 1 Enlever le panneau de bout
7. REGENCY Guide d installation et d utilisation MODELES Table basse Ilot AVERTISSEMENT USAGE EXT RIEUR SEULEMENT AVERTISSEMENT MISE EN GARDE POUR VOTRE PROPRE S CURIT Assurez vous de bien suivre les oo instruction dans cette notice pour Que faire si vous sentez une odeur de gaz r duire au minimum le risque d incendie s Coupez le gaz allant vers l appareil ou d explosion ou pour viter tout Ne tentez pas d allumer l appareil dommage materiel toute blessure ou Eteignez toutes les flammes nues la mort T oren AUS tre EE FA I tee de appareil et appelez imm diatement votre fournisseur AVERTISSEMENT de gaz ou les pom iers es blessures ou des dommages Netouchezaucun interrupteur lectrique n utilisez aucun mat riels peuvent survenir en t l phone cas de mauvaise installation de Appelez imm diatement votre fournisseur de gaz depuis r glages incorrects d alterations un voisin J 7 7 A 7 d x ou d entretien inad quat Lisez avec Suivez les instructions du fournisseur soin les instructions d installation de Sj vous ne pouvez rejoindre le fournisseur de gaz appelez fonctionnement et d entretien avant le service d installer ou d effectuer l entretien de cet quipement L installation et l entretien doivent tre MISE EN GARDE M K assur s par un installateur ou un serv N entreposez pas et n utilisez pas de essence ou d autres v
8. foyer Portez des gants et des lunettes de s curit au moment d effectuer l entretien La pression de l entr e du gaz maximum 1 2 psig Ne modifiez cet appareil sous aucune circonstance Les pi ces retir es pour l entretien doivent tre replac es avant d utiliser l appareil L installation et les r parations de cet appareil daivent tre confi s un technicien qualifi Un professionel devrait effectu une inspection de cet appareil annuellement Prenez l habitude de faire inspecter tous vos appareils au gaz annuellement Ne jamais br ler de combustible solide bois papier carton charbon etc dans cet appareil 10 Avant de v rifier la pression du syst me d alimentation plus de 1 2 psi 3 5k Pa d brancher compl tement l appareil et sa sou pape d arr t de l alimentation en gaz Avant de v rifier la pression du syst me d alimentation 2 psi 3 45 kPa ou moins isoler l appareil en fermant la soupape d arr t manuel 11 N entreposer aucun combustible essences ou autres vapeurs et liquides inflammables proximit de l appareil Pour viter que de l humidit neige pluie p n tre l int rieur de l appareil couvrir son ouverture lorsqu il ne sert pas Utiliser uniquement le type de gaz indiqu sur la plaque signal tique Ne pas con vertir l appareil d autres combustibles sauf au moyen d une trousse de conversion homologu e 12 Enlever toujours le capot de protection
9. l allure de chauffe est ad quate telle qu inscrite sur l tiquette de s curit Au besoin r gler l entr e d air primaire pour viter que les flammes ne produisent de carbone Faire fonctionner l appareil de 15 20 minutes au pr alable pour laisser le temps aux flammes de se stabiliser AVERTISSEMENT Le fabricant n est pas re sponsable des dommages occasionn s par la production de suie ou de carbone la suite d une modification de l appareil Regency Plateau Foyer gaz ext rieur INSTALLATION CHOISIR L EMPLACEMENT DE VOTRE FOYER 1 Avant d installer cet appareil il faut d abord s assurer de respecter les diff rents d gagements indiqu s dans le pr sent document 2 Cet appareil doit tre install dans un endroit ouvert qui b n ficie d une circulation d air constante et d une ventilation naturelle et o les missions de gaz et les produits de combustion sont rapidement dispers s par le vent et l a ration naturelle 3 Certains mat riaux ou articles peuvent devenir dangereux s ils sont plac s proximit de l appareil et expos s la chaleur qui s en d gage 4 G n ralement on entend par ext rieur un espace ouvert sans mur Si ce n est pas le cas l espace en question doit respecter les exigences d crites ci dessous Espace ferm par des murs de tous les c t s sans toit avec au moins une ouverture permanente au niveau du sol Dans le
10. liquide PL ou source de gaz naturel REMARQUE une fuite de gaz produira des bulles de savon 5 REFAIRE LES TAPES 1 ET 2 INVERS ES 2 Enlever le panneau lat ral le panneau de gauche lorsque vous faites face au panneau o se trouve l interrupteur pour acc der au raccord de 3 8 po de la commande de gaz Regency Plateau Foyer gaz ext rieur INSTALLATION CONVERSION AU PROPANE LIQUIDE L INSTALLATION DOIT ETRE EFFECTU E PAR UN MONTEUR QUALIFI EN CAS DE DOUTE NE RIEN MODIFIER Each Kit contains one LP Conversion Kit 4 D visser l orifice du br leur a l aide d une cl po et le mettre de c t Se servir d une autre cl pour stabiliser le coude l arri re de l orifice Contenu de la trousse de conversion au propane 379 972 Qty Part Description 1 911 009 Orifice de br leur no 54 1 904 529 Cl hexagonale 5 32 po 1 918 590 Autocollant Converti au propane liquide 1 908 528 tiquette rouge Propane liquide 1 911 009 R gulateur de pression Hi Lo pour soupape 886 1 911 089 R gulateur et conduite de propane 48 po 919 000 Livret d instructions 1 Couper l alimentation en gaz et laisser l appareil refroidir la temp rature ambiante 2 Retirer les quatre vis qui retiennent le br leur tel qu illustr ci dessous S il y a lieu enlever les cristaux de verre au pr alable 3 Glisser le br leur vers la gauche de fa on d
11. support 2 Assurer que le r sevoir est ferm D brancher le gas 4 Placer le r servoir sur le plateau coulissant et le fixer solidement en vissant l crou oreilles 3 Faire glisser le r servoir de PL en tirant la poign e du plateau coulissant Remarque NE PAS POUSSER LE PLATEAU PAR LE HAUT DU R SERVOIR l crou oreilles 5 Pousser le plateau par le bas NE PAS POUSSER LE PLATEAU PAR LE HAUT DU R SERVOIR 6 Raccorder le r gulateur de PL branchement rapide au r servoir 7 Avec de l eau savonneuse v rifier la pr sence de fuites dans les entr es de gaz tirant la poign e sous pression d utilisation normale soupape d chappement et r servoir de PL ou source de gaz naturel o 4 D visser l crou oreilles pour laisser reposer le r servoir sur le support P Savon 5 Remplire le reservoir et r installer par renverser les tapes Raccord du gaz au r servoir Avertissement lorsqu un r servoir de PL est utilis un cart d un moins 1 po doit tre maintenu en tout temps entre la surface et la base du br leur consulter le manuel du propri taire P crou oreilles Regency Plateau Foyer gaz ext rieur INSTALLATION L INTERRUPTEUR 1 Retirer le panneau d acc s de l appareil c t interrupteur 2 S parer les deux fils de l interrupteur 3 Remplacer le panneau INSTALLATION DES PILES 1 Enlever le panneau de gauche o se trouve l int
12. 5 so sD vo D x 6 D 309 coz do 2 Q C i 0 TE QE 2 nie EO sf 5 COS Sess e2s FY GE DC O gt N n an 5 S a 5 VY SU E S D o ord DE Vi Se ES OF 320 SO 43 D SE 6 gt A u v a M os Ng S S SEE ST Z J E OG o 225 a O O a O w 3 Faa Zoe O y V O x O C aix T Z eff es L 7 8 Sr 9257 Luc BE B_y p G 3009 ver V ES G OD G S dQ S FS uot vs qc C n C gt 2 2 ar Fe o W 2 9 O Y O Q Z Z SE Pgz cee 28 SEE Regency Plateau Foyer gaz ext rieur EE DIMENSIONS DU TABLE BASSE
13. DULTES DEVRAIENT TRE INFORMES DES DANGERS QUE POSENT LES TEMP RATURES DE SURFACE LEV ES ET SE TENIR DISTANCE AFIN D VITER DES BR LURES OU QUE LEURS V TEMENTS NE S ENFLAMMENT CET APPAREIL DOIT ETRE UTILISE A L EXT RIEUR SEULEMENT ET DANS UN ENDROIT BIEN AERE NE PAS UTILISER DANS UN BATIMENT UN GARAGE OU TOUT AUTRE ENDROIT FERME N UTILISEZ PAS CET APPAREIL SI UNE PARTIE QUELCONQUE A ETE SUBMERGEE CONTACTEZ IMMEDIATEMENT UN TECHNICIEN DE SERVICE QUALIF E POUR INSPECTER L APPAREIL ET POUR REMPLACER TOUTE PIECE DU SYSTEME DE CONTROLE ET DU CONTROLE DU GAZ QUI AURAIT ETE SUBMERGEE ON NE DEVRAIT PAS PLACER DE VETEMENTS NI D AUTRES MATIERES INFLAMMABLES SUR L APPAREIL NI PROXIMITE LES JEUNES ENFANTS DOIVENT ETRE SOIGNEUSEMENT SURVEILLES QUAND ILS SONT A PROXIMITE DE L APPAREIL INFORMATIONS DE S CURIT G N RALE 1 L installation de cet appareil doit doit tre conforme aux codes locaux ou en leur absence au Code CAN CGA B149 1 Gaz Naturel et Propane CAN CGA B149 2 ou National du Gaz ANSI Z223 1 NFPA 54 2 Consultez les instructions g n rales de construction et d assemblage 3 4 8 9 Inspecter le brdleur avant chaque utilisation pour s assurer qu il n y a aucune obstruction et qu il est en bon tat Afin de pr venir les blessures ne pas confier le fonctionnement de l appareil une personne qui n est pas famili re avec se
14. Foyer a gaz ext rieur INSTRUCTIONS D UTILISATION CONSINGE D ALLUMAGE La plaque d allumage est situ e sous le panneau d acc s avant de l appareil FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand This appliance must be installed in accordance with local codes if any B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the floor because some gas is heavier than air and will settle on the floor Natural Gas and Propane Installation Codes CSA B149 1 WHAT TO DO IF YOU SMELL GAS WARNING If you do not follow these instructions exactly a fire or Do not try to light any appliance explosion may result causing property damage personal injury or Do not touch any electric switch do not use any phone in your building loss of life Improper installation adjustment alteration service of Immediately call your gas supplier from a neighbours phone Follow the gas supplier s instructiong maintenance can cause injury or property damage Refer to the owner s If you cannot reach your gas supplier call the fire department information manual provided with this appliance For assistance or A Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse additional information consult a qua
15. STRUCTIONS Regency Plateau Series Foyer a gaz ext rieur doit tre install en respectant ces directives Veuillez lire attentivement les pr sentes directives avant de proc der Consultez les autorit s responsables pour savoir si vous devez vous procurer un permis au pr alable L installateur doit S assurer que l appareil est install conform ment aux directives du fabricant et aux codes en vigueur AVANT DE DEBUTER Une installation et une op ration s curitaires de cet appareil n cessitent du bon sens toutefois le Ca nadian Safety Standards et l ANSI Standards nous demandent de vous fournir certaines informations LINSTALLATION ET LA REPARATION DEVRAIT ETRE CONFIEES A UN TECH NICIEN QUALIFI L APPAREIL DEVRAIT FAIRE L OBJET D UNE INSPECTION PAR UN TECHNICIEN PROFESSIONNEL AVANT D TRE UTILISE ET AU MOINS UNE FOIS L AN PAR LA SUITE DES NET TOYAGES PLUS FREQUENTS PEUVENT ETRE NECESSAIRES SI LES TAPIS LA LITERIE ET CETERA PRODUISENT UNE QUANTITEIMPORTANTE DE POUSSIERE IL EST ESSENTIEL QUE LES COMPARTI MENTS ABRITANT LES COMMANDES LES BRULEURS ET LES CONDUITS DE CIR CULATION D AIR DE L APPAREILSOIENT TENUS PROPRES B P ENLEVES POUR ASSURER L ENTRETIEN DE L APPAREIL DOIVENT TRES REMIS EN PLACE AVANT DE FAIRE FONCTIONNER L APPAREIL VANT D UTILISER L APPAREIL AVERTISSEMENT NE PAS INSTALLER CET APPAREIL CORRECTEMENT AN NULERA VOTRE GARANTIE ET POURRA CAUSER UN INCENDIE LES ENFANTS ET LES A
16. TION INSTALLATION DU CAPOT PROTECTEUR TABLE BASSE TABLE BASSE 1 RECOUVRIR LE BRULEUR LORSQU IL N EST PAS UTILIS 1 Placer le capot protecteur sur l enceinte en verre lorsqu elle n est pas utilis e l ilot et bar AVERTISSEMENT 1 Placer le capot protecteur sur le br leur lorsqu il n est pas utilis Ne jamais allumer le br leur s il est recouvert du capot pro tecteur Laisser refroidir le br leur avant de le recouvrir du capot protecteur Fermer l alimentation en gaz avant de recouvrir le br leur du capot protecteur Regency Plateau Foyer a gaz ext rieur INSTRUCTIONS D UTILISATION INSTRUCTIONS D UTILISATION 1 Lire et comprendre ces instructions avant d utiliser cet appareil 2 V rifier que toutes les installations lectriques sont encloisonn es pour pr venir les chocs 3 V rifier qu il n y a pas de fuites de gaz 4 V rifier la disposition des b ches Sila veilleuse n est pas visible lorsque l appareil est allum c est que les buches sont mal install es 5 L appareil ne devrait jamais tre allum et teint sans avoir attendu au moins 60 secondes INSTRUCTIONS D ALLUMAGE 1 Appuyez le bouton ON OFF 2 Attendre 4 secondes Le systeme d allumage produira des tincelles pendant 60 secondes afin d amorcer le br leur principal 3 Le Foyer s allumera REMARQUE Au premier allumage le systeme tente d allumer les flammes pendant 60 secondes Si T essai est i
17. a sauna contient 70 pierres e 1 paquet de pierres jardin contient 50 pierres Recommand utiliser seulement 40 des 70 pierres c ramiques sur le br leur du HZ30E Recommand utiliser seulement 24 des 70 pierres c ramiques sur le br leur du HZI234E Recommand utiliser seulement 50 des 70 pierres c ramiques sur le br leur du P33S P33SE REMARQUE Cristaux de verre vendus en sac de 1 livre et de 5 livres Tous les appareils sont livr s de s rie avec des cristaux de verre bleu cobalt l exception du mod le HZ042 qui les cristaux de verres en cuivre BR LEUR EXT RIEUR PTO30 Plateau Series 50 pierres avec 5 livres verres 100 pierres 2 pacquets a 5lvs verres Cristaux de verres montr s sur le br leur Pierres de Sauna optionel Cristaux de Verres montr s sur le br leur Pour HZ54E HZ54EPV HZ42ST HZ42STE HZ42STEPV HZ42E For Units HZ54E HZ54EPV HZ42ST HZ42STE HZ42STEPV HZ42 HZ42 HZ30E HZO42 PTO30 Plateau Series seulement HZ42E HZ30E seulement f HR Cirstaux de verres 7 lbs montr s sur le br leur et plancher de la chambre de combustion Pour HZI390E HZI390EB seulement Pierres de sauan optionel montr s sur le br leur Pour P33S P33SE L676S U32S U32SE E33S seulement Pierres de jardin optionel Cristaux de verres montr s sur le Pierres de lave Cristaux de br leur or Pour PTO30 amp Plateau Series Cristaux de verres montr s sur le br leur P
18. apeurs et liquides ice d entretien qualifi ou le fournisseur inflammables proximit de cet appareil ou de tout autre appareil de gaz Tested by LISTED Intertek 919 013 FPI DECORATIVE GAS APPLIANCE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 05 24 11 m Au Nouveau Propri taire Felicitations Vous tes le propri taire d un appareil au gaz fabriqu par REGENCY FIREPLACE PRO DUCTS La S rie de po le a gaz fabriqu s la main par Regency Fireplace Products a ete congue pour vous procurer toute la chaleur et le charme d un po le au bois au simple toucher de l interrupteur Les mod les sont homologues par Warnock Hersey pour la s curit et l efficacit Comme notre marque de commerce y est appos e ce produit vous procurera conomie confort et s curit et ce a l abri des ennuis pour les ann es a suivre S il vous plait prenez un instant pour vous familiariser avec ces instructions et les particularit s de votre appareil Fireplace Products International Ltee CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS Ra We recommend that our products be INSTITUTE installed and serviced by professio
19. avant 13 d allumer l appareil Couper l alimentation lorsque l appareil ne sert pas pendant de longues p riodes La combustibles utilis s pour les appareils gaz au bois et au mazout de m me que le produit de leur combustion contiennent de produits chimiques que l tat de la Californie consid re comme canc rig ne et respon sables d anomalies cong nitales et d autres pathologies du syst me reproductif Regency Plateau Foyer gaz ext rieur 1 2 3 4 5 6 AIDE MEMOIRE POUR L INSTALLATION Choisir l emplacement de l appareil a Emplacement consulter la section Choisir l emplacement de l appareil b D gagement aux mat riaux combustible consulter la section D gagements Installer l interrupteur ON OFF Marche Arr t S assurer qu il se trouve sur la position OFF Raccorder les tuyaux de gaz s assurer qu il n y a aucune fuite Ins rer quatre piles AA dans le bloc piles Installer les caract ristiques standard et optionnelles Consulter les sections suivantes Cristaux de verre Installation de pierre de jardin optionnel Installation de bdches optionnel Installation du table Installation du pare vent en verre Installation du capot protecteur ad ANTA Faire une derni re v rification Cette derni re v rification comprend les tapes suivantes 1 2 Chronom trer appareil afin de s assurer apr s 15 minutes de fonctionnement que
20. ble Une fois en bonne position soulever une extr mit appliquer un ruban double face qui a t coup la taille au dessous des ferrures R p ter le processus l autre extr mit Appuyer ferme ment pour fixer le contour de verre en position 22 Regency Plateau Foyer a gaz ext rieur INSTALLATION INSTALLATION DU DESSUS TABLE BASSE Avant d installer les panneaux suivre les directives ci dessous Panneaux en acier inoxydable Inspecter les panneaux pour s assurer qu ils ne sont pas gratign s ni boss s Signaler tout dommage sur le champ Aucune r clamation ne sera accept e apr s leur installation e Pour prot ger le fini des panneaux au cours de l installation et de la manipulation PORTER des gants de coton en tout temps m me pour en retirer le film protecteur eL acier inoxydable se d colore l g rement avec le temps Cette d coloration est normale et n est pas consid r e comme un d faut NETTOYER les empreintes de doigts l aide d un linge doux et d un nettoyant sp cialement con u pour l acier inoxydable Terminer avec un nettoyant base dammoniaque du lave vitre par exemple pour bien enlever la pellicule ou les r sidus qui pourraient rester Suivre ces tapes la lettre avant de faire fonctionner l appareil pour viter que la chaleur br le et tache les panneaux Ces taches ne s enl vent pas et ne sont pas couvertes par la garantie REMARQUE ces instructions s a
21. cas d un espace partiellement ferm muni d un toit et de plus de deux murs pr voir galement e Un c t ouvert dont la superficie quivaut au moins 25 de la superficie totale des murs et e Des ouvertures permanentes dont la superficie quivaut au moins 30 de la superficie restantes des murs Des ouvertures permanentes dont la superficie quivaut au moins 30 de la superficie restantes des murs un c t ouvert dont la superficie quivaut au moins 25 de la superficie totale des murs INSTALLATION DEGAGEMENTS Les d gagements ci dessous indique les distance minimale sauf indication contraire Le non respect des d gagements obligatoires espaces vides des mat riaux combustibles repr sente l une des principales causes des feux Il est donc primordial d installer le foyer conform ment aux presentes directives ATTENTION Mise en garde Le non respect de ces modifications accroit grandement les risques d incendie Exigences respecter Le dessus l arri re et les c t s du foyer sont d limit s par des dispositifs d espacement NE PAS encastrer les extr mit s en m tal de ces dispositifs dans des mat riaux Il est donc primordial d installer le foyer et le syst me de ventilation conform ment aux pr sentes directives Plateau Series Clearance Requirements D gagements Dimension Mesurer partir du A Mur arri re 17 432mm C t du Br leur B M
22. e 21 PIS EE A E cabins 21 Copy of Lighting Plate Instructions 22 Regency Plateau Foyer a gaz ext rieur TABLE DES MATIERES MAINTENANCE Maintenance Instructions 23 Switch replacement ee ee e e 24 Valve assembly replacement 25 Digital fireplace control replacement 26 Battery replacement see eee eee eee eee eee 26 PARTS ES SE EE AT 27 WARRANTY Limited Warranty sese eee eee 31 va ETIQUETTE DE SECURITE V 7 TIQUETTE DE S CURIT UO C O Q jon D Op Z w co ES SR EE RE EE TE EEE RENT DEE TE ER DR ET TEA VE TESE TET EET a Listed OUTDOOR DECORATIVE GAS APPLIANCE EXT RIEUR D CORATIFS APPAREIL GAZ Serial No No de serie Minimum Clearances to Combustibles NIW Certified for Certifi e pour CANADA and U S A YREGENGY 386 Degagement Minimum De Materiaux Combustibles meter Tested to ANSI Z21 97 2010 US CR97 003 CAN CAN CGA 2 17 M91 en 4001172 DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE ETIQUETTE A 17 432mm I I I I l l APPAREIL FONCTIONNANT AU NATURAL GAS Side Wall I NATURAL GAS Model PLATEAU SERIES CONCU POUR ETRE POELE Mod le PLATEAU S RIE PROPANE GAS Model PLATEAU SERIES CONCU POUR ETRE POELE Mod le PLATEAU SERIE B 17 432mm i Maximum supply pressure 14 WCI C E 3 49kPa Pression d al
23. ered under the terms of the warranty policy Performance problems due to operator error will not be covered by this warranty policy Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI may create a danger and nullify your warranty on this product Any alteration to the unit which causes sooting or carboning that results in damage to the interior exterior facia is not the responsibility of FPI Subsidy according to job scale as predetermined by FPI Regency Plateau Foyer a gaz ext rieur Installer Please complete the following information Dealer Name amp Address Installer Phone Date Installed Serial No Regency and Plateau are a registered trademark of FPI Fireplace Products International Ltd e O Copyright 2011 FPI Fireplace Products International Ltd All rights reserved Printed in Canada
24. errupteur 2 Rabattre le compartiment piles situ sous le panneau DFC Compartiment des piles 3 Ins rer quatre piles AA et refermer le compartiment en r p tant les tapes pr c dentes en sens inverse Regency Plateau Foyer gaz ext rieur INSTALLATION INSTALLATION DES CRISTAUX DE VERRE OU DES PIERRES R partir les cristaux de verre les pierres a sauna en c ramique ou les pierres de jardin uniform ment sur le br leur en veillant ne pas trop les chevaucher afin d obtenir un bel effet de flammes IMPORTANT Utiliser uniquement les pierres ou les cristaux de verre approuv s et fournis L utilisation de tout autre type de cristaux ou de pierres peut nuire au rendement de l appareil et occasionner des dommages non couverts par la garantie Disposer les pierres en c ramique ou de jardin de fagon a NE PAS obstruer les orifices de la veilleuse et ne pas trop les chevaucher afin d obtenir un bel effet de flammes HZ54E HZ54EPV 1 livre Verre 2 paquets 140 pierres sauna HZ42 HZ42E 1 Ib Verre 1 paquet 70 pierres sauna HZ42 ST HZ42STE 2 livres 1 Ib Verre 1 paquet 70 pierres Sauna HZ42STEPV REMARQUE Cristaux de verre vendus en sac de 1 livre et de 5 livres Tous les appareils sont livr s de s rie avec des cristaux de verre bleu cobalt l exception du mod le HZI390E HZI390EB PTO30 amp Plateau Series dont les cristaux sont vendus s par ment e 1 paquet de pierres
25. eur et refaire les tapes pr c dentes en sens inverse Regency Plateau Foyer gaz ext rieur ENTRETIEN REMPLACEMENT DE LA SOUPAPE teindre le foyer et laisser l appareil refroidir la temp rature ambi 8 Le soulever et l enlever ante 1 Retirer les quatre vis qui retiennent le br leur tel qu illustr ci dessous S il y a lieu enlever les cristaux de verre au pr alable 2 Glisser le br leur vers la gauche puis le soulever 9 Remplacer le joint d tanch it au besoin 10 Mettre le nouveau plateau en place 11 Remettre le bouton Hi Lo enlev l tape 6 12 R installer le br leur en suivant la proc dure invers e des tapes 5 1 3 Couper l alimentation en gaz et d monter le raccord flexible reli la soupape 4 D brancher le fil orange EV1 de la soupape 5 D brancher le fil vert EV2 de la soupape 6 Enlever le bouton Hi Lo Hi Lo Extension Pa PR ae ee Pu N Le R w 7 EV1 terre d flamme 7 Retirer les dix vis qui retiennent le plateau de la soupape aux endroits indiqu s ci dessous EI Regency Plateau Foyer a gaz ext rieur mn REMPLACEMENT DU BOITIER DE COMMANDE NUMERIQUE 1 Retirer le panneau d acc s gauche de l appareil 4 D brancher le faisceau de fils et le fils de mise la terre rouge du capteur de flamme
26. ill go into lock out Il faut alors le r initialiser en suivant les vous devez d brancher compartment clean The system will need to be reset as follows after going tapes ci dessous pour le d verrouiller l appareil du bloc piles voir le See installation into lock out mode a Attendre 5 minutes et teindre l appareil en manuel d instruction pour plus and operating a Wait 5 minutes turn the system off using ON OFF Jen Mee ae one dei GE de d tails instructions switch endre 2 secondes et rallumer le syst me accompanying b After approximately 2 seconds turn on ON OFF switch l aide de l interrupteur DO NOT REMOVE appliance c Unit will repeat step 2 c L unit r p tera l tape 2 THIS INSTRUCTION PLATE 918 892a Regency Plateau Foyer gaz ext rieur ENTRETIEN 1 2 4 INSTRUCTIONS D ENTRETIEN Toujours fermer la soupape avant de proc der au nettoyage Pour le r allumage r f rez vous aux instructions d allumage Conservez le br leur et le contr le propres en les nettoyant au moyen d un aspirateur au moins une fois par ann e Nettoyez les bUches avec un pinceau pour ne pas les endommager Nettoyez l appareil avec un linge humide Ne jamais utiliser un nettoyeur abrasif Nettoyez la vitre avec un produits de nettoyage con u pour les foyers a gas NETTOYER les empreintes de doigts l aide d un linge doux et d un nettoyant sp cialement con u pour l acier inoxydable Terminer avec un
27. lified installer service agency Ne tentez pas d allumer la veilleuse manuellement or gas supplier l l B AVANT DE FAIRE FONCTIONNER reniflez tout autour de l appareil pour d celer une odeur AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions x E k de gaz Reniflez pr s du plancher car certains gaz sont pluslourds que l air et peuvent dans la pr sente notice risquede d clencher un incendie ou une explosion s accumuler au niveau du sol entrainant des dommages des blessures ou la mort QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Une installation d ajustement de modification de service ou Ne pas tenter d allumer d appareil d entretien peut provoquer des blessures ou des dommages materi Ne touchez aucun interrupteur ne pas vous servir des t l phones se trouvant dans le els Reportez vous au manuel du propri taire de l information fournie b timent avec cet appareil Pour obtenir de l aide ou des informations suppl e Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les mentaires consulter un installateur qualifi une agence de service ou instructions du fournisseur fournisseur de gaz Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies CAUTION LIGHTING INSTRUCTIONS 1 Appuyez le bouton ON OFF 1 Hot while in 2 Attendre 4 secondes Le syst me d allumage produira TO TURN OFF operation Do not STOP Read the safety information on this label
28. limentation maximum Maximum supply pressure 14 WC C E 3 49 kPa Pression d allimentation maximum Ceiling Minimum supply pressure 5 WC C E 1 25 kPa Pression d allimentation minimum Minimum supply pressure 11 WC C E 2 74 kPa Pression d allimentation minimum C 45 1143mm Manifold pressure high 35 WC C E 0 87 kPa Pression la tubulure d chappement lev e Manifold pressure high 10 WCIC E 249 kPa Pression la tubulure d chappement lev oe DE Manifold pressure low 1 6 WC C E 0 40 kPa Pression la tubulure d chappement basse Manifold pressure low 6 4 WCIC E 1 59 kPa Pression la tubulure d chappement basse 25mm Orifice size 25 DMS Grandeur de l injecteur Orifice size 45 DMS Grandeur de l injecteur Maximum input 50 000 Btu h 14 65kW D bit Calorifique maximum selon Maximum input 49 000 Btu h 14 36 KW D bit Calorifique maximum selon i Minumum input 30 000 Btu h 8 79kW D bit Calorifique minimum selon Minumum input 38 000 Btu h 11 13 KW D bit Calorifique minimum selon Altitude 04500 fpi 0 1372 m l altitude Altitude 04500 ftpi 0 1372 m l altitude Made in Canada Fabrique au Canada 1 The installation must conform with local codes or in the absence of local codes with CAN CSA B149 1 Natural Gas and Propane Installation Code or ANSI Z223 1 NFPA 54 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with
29. n verre et le dessus 2 ENLEVER LES DEUX PANNEAUX DE BOUT ET LE R SERVOIR DE PL S IL EST D J INSTALL VOIR LA SECTION PORTANT SUR L ENL VEMENT DU R SERVOIR DE PL DANS LE MANUEL D INSTALLATION SI LILOT EST RACCORDE A UNE CONDUITE DE GAZ NATUREL FERMER L ALIMENTATION EN GAZ 6 Fixer l lot sur le socle en alignant les trous de vis et en s assurant que le drain de vidange passe travers le trou du drain de vidange du socle de l ilot 3 Enlever les panneaux de bout et les panneaux lat raux et les d poser sur une surface lisse et propre 7 Sile bar est utilis avec un raccord d alimentation en gaz naturel positionner le socle de sorte que les jecteurs de l alimentation en gaz se retrouvent au dessus du raccord d alimentation sauf si un r servoir de PL est utilis Enlever les panneaux du socle en tenant fermement le fond et en les soulevant vers l arri re Les d poser sur une surface lisse et propre 4 Enlever les 4 pattes en caoutchouc sous l lot pour les installer sous le socle de lot l encoches E Regency Plateau Foyer gaz ext rieur INSTALLATION Oa 8 Fixer solidement l lot au socle l aide de 12 vis tel qu illustr ci dessous 9 Installer le r servoir et le raccorder ou raccorder l alimentation en gaz naturel R INSTALLER LES PANNEAUX LE DESSUS ET L ENCEINTE EN VERRE POUR TERMI NER L INSTALLATION E3 Regency Plateau Foyer a gaz ext rieur INSTALLA
30. nal Fuel Gas Code ANSI Z223 1 en vigueur N utilisez que de raccords flexible ou en Cuivre approuves Installez toujours un raccord union pour que la conduite de gaz soit facilement d montable pour permettre l entretien du br leur et du ventilateur Habituellement l utilisation d crous coniques pour les conduits de cuivre et les raccords flexibles satisfait cette exigence REMARQUE Un robinet d arr t Dante doit tre fourni dans l appareil ou proximit conform ment aux codes municipaux pour faciliter l entretien de cet appareil Important Toujours v rifier s il y a des fuites de gaz avec une solution d eau et de savon Ne pas tester avec une flamme nue Regency Plateau Foyer gaz ext rieur AJUSTEMENT DU PILOTE V rifier les flammes du pilote p riodiquement Corrigez le patron de la flamme afin d obtenir 2 flammes bleues vives 1 autour du sonde de flamme et 1 l arri re du br leur elle n a pas toucher au br leur Burner 00 00000 O O OO O O O A0000000 Flame Sensor Pilot Ignitor REMARQUE Si le patron de la flamme n est pas ad quat contactez votre d taillant de Regency pour de plus amples instructions Un patron de flamme inad quat pr sentera une petite flamme probablement jaune laquelle n entrera pas correctement en contact avec l arri re du br leur ou avec la thermopile VERIFIER LA PRESSION DU GAZ Isoler l appareil en fermant la soupape d arr t man
31. nals who are certified in the U S by the National Fireplace Institute NFI or in Canada by Wood L B Energy Technical CERTIFIED Training WETT Wood Energy Technical Training Regency Plateau Foyer gaz ext rieur SAFETY LABEL Copy of Safety Decal 4 DIMENSIONS Unit Dimensions Coffee table 5 Unit Dimensions Island table 6 Unit Dimensions Island riser 7 INSTALLATION Important Message eee eee eee 8 Before TE EE 8 General Safety Information 8 Installation Checklist 9 Locating Your Outdoor Decorative Gas appliance 9 Minimum Clearances to combustibles 10 High EN GE 11 Gas Line Installation 11 Pilot Adjustment rreren 11 Gas Pipe Pressure Testing 11 886 S I T Valve Description 11 Aeration Adjustment eee eee ee 11 Wiring PAIN EE 12 Table top installation see eee ee 13 For Island and Cocktail units only 13 LP Tank installation removal eee ee eee 14 Glass crystal garden stone installation 15 Optional Log Set Installation 16 Optional Glass Surround Installation 18 Conversion from Ng to Lp 19 OPERATING INSTRUCTIONS Operating Instructions eee eee ee eee 21 Lighting Proced re EE ET 21 Shutdown Procedure sss ses
32. nettoyant base d ammoniaque du lave vitre par exemple pour bien enlever la pellicule ou les r sidus qui pourraient rester Suivre ces tapes la lettre avant de faire fonctionner l appareil pour viter que la chaleur br le et tache les panneaux Ces taches ne s enl vent pas et ne sont pas couvertes par la garantie L appareil est recouvert d une peinture r sitante la chaleur et aucune autre peinture ne devrait tre employ e Regency utilise la Peinture Noire M tal lique 6309 5 V rifiez p riodiquement la position et l tat du br leur ainsi que la stabilit de la flamme S il y a un probleme t l phonnez un technicien qualifi 6 7 8 L appareil doit tre inspect avant d tre utilis s et au moins une fois pas ann e par un technicien qualifi afin de s assurer qu ils ne sont pas obstru s Ne pas utiliser cet appareil s il a t plong m me partiellement dans l eau Appeler un technicien qualifi pour inspecter l appareil et remplacer toute partie du syst me de et toute commande qui a t plong e dans l eau Assurez vous que le fonctionnement est ad quat apr s l entretien Regency Plateau Foyer a gaz ext rieur ENTRETIEN REMPLACEMENT DE L INTERRUPTEUR 1 Retirer le panneau d acc s de l appareil c t interrupteur 2 S parer les deux fils de l interrupteur 3 D visser les deux vis qui retiennent le couvre interrupteur et l enlever 4 Remplacer l interrupt
33. nfructueux le syst me fait une pause de 35 secondes C est ce qu on appelle l tape de rectification Ce d lai coul le syst me tente nouveau d allumer les flammes en produisant des tincelles pendant 60 secondes Si les flammes ne s allument toujours pas le syst me se met en mode verrouillage Il faut alors le r initialiser en suivant les tapes ci dessous a teindre l appareil en r glant l interrupteur la position OFF b Attendre 2 secondes et rallumer le syst me l aide du commutateur c R p ter l tape 2 INSTRUCTIONS D ARRET 1 Utilisez l interrupteur ON OFF du Br leur ou du contr le distance pour teindre le br leur 2 Avant d effectuer l entretien ou la r para tion de l appareil couper toutes les sources d alimentation en d branchant l appareil et en enlevant la pile PREMIER FEU Le premier feu du foyer contribue au s chage de la peinture de finition Pour que la peinture soit compl tement s che ilest recommand delaisser chauffer le foyer pendant au moins quatre 4 heures lors de la premi re utilisation Au premier allumage l appareil d gagera une odeur caus e par le s chage de la pein ture et par la combustion des substances huileuses utilis es dans sa fabrication Le panneau de verre pourrait n cessiter un net toyage lorsque l appareil sera refroidi NE PAS TENTER DE NETTOYER LA VITRE LORSQU ELLE EST ENCORE BRULANTE Regency Plateau
34. our HZO42 PTO30 amp Plateau seulement Pour P33S P33SE L676S U32S U32SE E33S seulement Series seulement Regency Plateau Foyer a gaz ext rieur INSTALLATION INSTALLATION DES BUCHES Eh Lire attentivement les directives suivantes et se r f rer aux illustrations fournies Ne pas faire fonctionner un appareil si les b ches sont endommag es car elles peuvent nuire au bon fonctionnement de la veilleuse Il convient donc de les faire remplacer au pr alable Le fabricant n est pas responsable des dommages occasionn s par la production de suie ou de carbone la suite d une modification de l appareil Contenu de l ensemble de b ches 326 930 Part B che A 1 Bache B 1 Bache C 1 Bache D 1 Bache E 1 Biche F 1 Sch ma 1 1 Installer le boche A comme le montre ci dessous Orienter le boche dans la m me mani re et dans le m me endroit sur le c t droit du br leur comme le montre au sch ma 2 Sch ma 2 2 Installer le b che D comme le montre ci dessous Orienter le boche dans la m me mani re et dans le m me endroit sur le c t droit du br leur comme le montre au sch ma 3 3 Installer le b che D comme le montre ci dessous Orienter le b che E travers le bdche C dans la m me mani re et dans le m me endroit comme le montre au sch ma 4 EJ Regency Plateau Foyer gaz ext rieur v INSTALLATION 4 Placer le b che B au c t gauche du b
35. ppliquent aux dessus de table en 3 Pour enlever le dessus r p ter ces tapes dans l ordre inverse acier inoxydable et bronze flamboyant 1 PLACER LE DESSUS SUR LA TABLE MONT E Installation finale 2 Fixer les capuchons sur la veilleuse et l extr mit oppos e pour terminer l installation embouts Regency Plateau Foyer gaz ext rieur INSTALLATION INSTALLATION DU PLATEAU POUR L ILOT ET BAR Composantes du plateau Tiles 19 1 8 x 11 3 4 Tiles 7x 13 4 HE Filler Brackets Table Top Frame REMARQUE MANIPULER ET INSTALLER LES CARREAUX AVEC SOIN 1 D poser le cadre de montage sur l appareil de fa on ce que son contour fini soit vers le haut 7 4 Poser ensuite les carreaux du centre 2 Aligner les trous de fixation du cadre sur ceux de l appareil et fixer le tout l aide de deux vis de chaque c t tel qu illustr ci dessous 3 Placer les 8 tranches sur le haut de la table voir Sch ma avant d installer les carreaux pattes de soutien 4 Pour installer les carreaux commencer par poser un carreau dans chaque coin Regency Plateau Foyer a gaz ext rieur s INSTALLATION INSTALLATION DU SOCLE DE L ILOT POUR CONVERTIR L LOT EN BAR Un socle peut tre install sous I ilot pour le convertir en bar 5 Installer les 4 pattes en caoutchouc r glables sous I ilot en les serrant la main 1 Si Tiot est d j assembl enlever l enceinte e
36. r leur comme le montre ci dessous Orienter le b che B dans la m me mani re et dans le m me endroit comme le montre au sch ma 5 Sch ma 5 5 Placer le boche F sur le br leur comme le montre ci dessous Orienter le bUche F au dessus du b che A comme le montre au sch ma 6 Sch ma 6 6 Placer le b che C au c t gauche du br leur comme le montre ci dessous Orienter le bUche B dans la m me mani re et dans le m me endroit comme le montre au sch ma 7 Sch ma 7 Installation Finale Regency Plateau Foyer gaz ext rieur INSTALLATION INSTALLATION DU CONTOUR EN VERRE OPTIONNEL 1 Assembler et fixer les quatre c t s du contour en verre l aide de 4 D terminer la hauteur des ferrures du bas l aide de l outil d espacement quatre ferrures d angle tel qu illustr ci dessous fourni Patte de soutien inf rieur Outil d espacement Patte de soutien sup rieur 2 Ins rer un taquet de nylon sous chacune des ferrures afin de les 5 Ins rer un taquet de nylon sous chacune des ferrures pour les maintenir maintenir en place galit avec le verre tel qu illustr ci dessous en place Le contour en verre devrait tre sur lev de po tel qu illustr ci dessous 3 Retourner le contour sur une surface prot g e puis installer les quatre ferrures du bas 6 Poser le contour en verre sur le dessus de table veiller ce verre est pa centr e sur la ta
37. s essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this information the warranty will be invalid Exclusions Batteries are not covered under warranty policy At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit FPI has no obligation to enhance or modify any unit once manufactured ie as products evolve field modifications or upgrades will not be performed FPI will not be liable for travel costs for service work Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy The warranty will not extend to any part which has been tampered with or altered in any way or in our judgment has been subject to misuse improper installation negligence or problems caused by environmental or geographical conditions inadequate ventilation Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer FPI will not be liable for acts of God or acts of terrorism which cause malfunction of the appliance Malfunction damage of this appliance due to mother nature wind rain snow etc is not cov
38. the Canadian Electrical Code CSA C22 1 or with the National Electrical Code ANSI NFPA 70 This appliance is only for use with the type of gas indicated on the rating plate See owner s manual for details L installation doit tre conforme aux codes locaux ou en l absence de codes locaux avec CAN CSA B149 1 gaz naturel et du propane ou du Code d installation au ANSI Z223 1 NFPA 54 I I I I I I I I I I I I I I I I I I i L appareil une fois install doit tre connect lectriquement la terre conform ment aux codes locaux ou en l absence de codes locaux avec le Code canadien de l lectricit CSAC22 1 ou avec le National Electrical Code ANSI NFPA 70 I I I I I I I 1 Cet appareil est a utiliser uniquement avec le type de gaz indiqu sur la plaque signal tique Voir le manuel du propri taire pour les d tails MODEL FOR OUTDOOR USE ONLY POUR USAGE EXT RIEUR SEULEMENT NOT FOR USE WITH SOLID FUELS FPI Fireplace Products International Ltd PTO30CFT NG C PTO30CFT LP IF STORED INDOORS DETACH AND LEAVE CYLINDER OUTDOORS _ NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDE Delta BC Canada VAG 114 OPTosIsT NG PTO30IST LP SI VOUS LE GARDER L INT RIEUR DETACHER LE CYLINDRE ET LAISSER L EXT RIEUR OPTO30CKT NG 0 PTO30CKT LP 919 015 TD gt I nN QU D coy GET EE Q T E Q O c n Cc MO E De n 3 co a o o O oc U Q D DO OO M Lu g gt 5 822 so oe D at
39. u br leur est r gl en usine mais peut n cessiter des modifications selon l altitude ou l alimentation en gaz locale Ouvrir l obturateur pour obtenir une flamme bleu Le fermer pour obtenir une flamme jaune L ouverture minimum d obturateur d air Gaz Naturel Propane Liquide Fermer 1 2po REMARQUE La garantie ne couvre pas les dommages occasionn s par l mission de carbone la suite d un mauvais r glage du d bit d air INSTALLATION On ae SCHEMAME DU FILAGE Cet appareil de chauffage peut fonctionner sans courant alternatif 120 volts Ne jamais couper la borne de mise la terre REMARQUE Le commutateur du br leur fonctionne avec 4 piles AA Configuration 0 886 001 Proflame Valve Standard Main On Off Switch Lorsque l appareil est install il doit tre mis la terre conform ment aux codes municipaux ou si de tels codes n existent pas conform ment au National Electrical Code ANSI NFPA 70 le cas ch ant 12 Regency Plateau Foyer a gaz ext rieur RACCORDEMENT AU GAZ 1 Enlever le panneau de bout o se trouve l interrupteur Des aimants 3 Brancher l alimentation en gaz retiennent les panneaux D poser le panneau sur une surfacelisse et propre Raccord du gaz au r servoir 4 Avec de l eau savonneuse v rifier la pr sence de fuites dans les entr es de gaz sous pression d utilisation normale soupape d chappement et r servoir de propane
40. uel avant de verifier la pression du systeme d alimentation psi 3 45 kPa ou moins A plus de 7 psi d saccoupler la conduite de la soupape La pression d admission est r gl e par un r gulateur int gr au dispositif de r glage du gaz La v rifier en m me temps que la pression REMARQUE Pour obtenir une lecture pr cise de la pression du gaz v rifier la pression d admission et la pression d alimentation aux orifices de refoulement de la soupape 1 Mettre l interrupteur la position OFF 2 Tourner le robinet manom trique IN et ou le robinet manom trique OUT vers la gauche l aide d un tournevis lame plate de 1 8 po 3 Fixerunmanom tre au moyen d un tuyau souple de 5 16 po de diam tre int rieur 4 Allumer la veilleuse en mettant l interrupteur a la position ON 5 V rifier la pression pendant que l appareil est en marche et s assurer que les parametres respectent les seuils sp cifi s sur l tiquette de s curit 6 Une fois la lecture obtenue fermer la soupape d brancher le tuyau souple et resserrer le ou les robinets l aide d un tournevis lame plate de 1 8 po Remarque Bien visser sans trop serrer DESCRIPTION DE LA SOUPAPE SIT 886 NOVA Pression de sortie Sortie du veilleuse Sortie principal du gaz Entr ee principal du gaz Sortie de gaz principale Entrer de gaz principale R GLAGE DU DEBIT D AIR Le debit d air d
41. ur lat ral 17 432mm C t du Br leur C Plafond 45 1143mm Dessus du Brdleur D Plafond Dessus du Foyer E Largeur de l alcove 4 2134mm Mur du c t au mur du c t Minimum F Profondeur de 60 1524mm Avant au paroi du fond Maximum l alcove Alcove 10 Regency Plateau Foyer a gaz ext rieur PLATEAU SERIES LP SYSTEM DATA Pression du Collecteur Haut 3 5 WC 0 87 kpa Pression du Collecteur Bas 1 6 WC 0 40 kpa Taille du Orifice du Br leur 25 DMS Apport maximal 50 000 Btu h 14 65 kW Pression d alimentation maximal 14 WC 3 49 kpa Pression d alimentation minimal 5 WC 1 25 kpa 30 000 Btu h 8 79 kW Apport minimal PLATEAU SERIES LP SYSTEM DATA Pression d alimentation maximal 14 WC 3 49 kpa 11 WC 2 73 kpa 10 WC 2 49 kpa 6 4 WC 1 59 kpa 45 DMS 49 000 Btu h 14 36 kW 38 000 Btu h 11 13 kW Pression d alimentation minimal Pression du Collecteur Haut Pression du Collecteur Bas Taille du Orifice du Br leur Apport maximal Apport minimal INSTALLATIONS HAUTES ALTITUDE Cet appareil est approuv e au Canada pour alti tudes jusqu 4 500 pi 1370m CANT 2 17 M91 INSTALLATION DE LA CONDUITE DE GAZ Comme certaines municipalit s ont leur propre code il est toujours pr f rable de consulter les autorit s locales et le code d installation CAN CGA B149 Aux tats Unis respecter les codes municipaux etle Natio
42. ve consideration any damage claim against stainless steel components must be submitted at the time of installation Damage from abrasive cleaners and discolouration to stainless components caused by heat are not covered under warranty Damage reported after installation will not be covered Repair replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt only Any item shown to be defective will be repaired or replaced at our discretion No labor coverage is included with these parts Conditions Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI s option through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It i