Installation, Operation and Maintenance Manual

image

Contents

1. VENTILAT CABLE Maintenir la gaine D ALIMENTATION Y la plus courte Ra i possible SR Sceller les interstices autour du caisson GAINE RONDE Sceller les raccords de Y 7 CHAPEAU la gaine avec MURAL z du ruban a registre Acheter d tanch it int gr s par ment 2 Ventilateurs d extraction de plafond SP Installation dans une construction neuve Outillage n cessaire Mat riels n cessaire e Gaine m tallique ronde de 6 po conseill e pour un fonctionnement optimal L utilisation d autres gaines est acceptable mais peut alt rer les performances Visseuse lectrique embout Phillips Tournevis Phillips Tournevis plat e Chapeau de toiture ou chapeau mural registre Pince int gr conseill Pince d nuder e Ruban d tanch it pour les raccordements de gaine Coupe c ble e Cablages et fournitures lectriques conformes au code de l lectricit en vigueur 1 D baller D tacher le masque de l em ballage Voir l tape 6 Enlever la fiche d instruction Le sachet de pi ces contient la plaquette d fon able et six 6 vis 2 Poser le b ti de montage A Ventilateurs d extraction de plafond SP EJ Installation dans une construction neuve 3 Enclencher et fixer le caisson Placer le caisson en
2. Fonctionnement Mettre le ventilateur en marche Mettre l interrupteur g n ral en position de marche e Le ventilateur fonctionne au d bit d air certifi si le s lecteur de mode est en position de marche e Le ventilateur fonctionne au d bit d air r gl par l utilisateur si le s lecteur de mode est en position d arr t Utiliser le changement de d bit d air temporis 1 Mettre l interrupteur g n ral en position de marche 2 Mettre le s lecteur de mode en position de marche le ventilateur fonctionne au d bit d air certifi 3 Lorsque le s lecteur de mode est mis en position d arr t le ventilateur continue de fonctionner au d bit certifi jusqu ce que la temporisation r gl e par l utilisateur soit coul e puis passe automatiquement au d bit r gl par l utilisateur R gler le d bit d air ajustable par l utilisateur Avec un petit tournevis plat tourner avec pr caution le r glage de d bit d air CFM pour faire pointer la fl che sur la valeur souhait e en pieds cubes par minute A 2 3 Vis du sachet de pi ces Si le plafond doit tre r par placer le masque dans le caisson une fois que la soufflante a t fix e Voir Installation dans une construction neuve tape 6 Enlever le masque avant de poser la grille R gler la temporisation ajustable par l utilisateur Avec un petit tournevis plat tourner avec pr caution le r
3. Wire cutter Utility knife 1 Remove Packaging Punch out Mask from packaging See Step 12 Remove Instruction JE Sheet Parts Bag holds Knockout Plate and six 6 screws 2 Switch Off Power WARNING Before removing existing fan switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Enlarge Ceiling Opening and Remove Existing Fan I 11 27 9 cm parallel with joists 12 30 5 cm h Existing ductwork and 1 wiring left in place 4 Examine Wiring N S Examine the existing wiring to make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair A SP Ceiling Exhaust Fans Retrofit Installation 5 Remove Blower Assembly Set aside Wiring Panel 2 Bend up four tabs Remove screws from Mounting Frame and set aside Em SP Ceiling Exhaust Fans Retrofit Installation 8 Secure Mounting Frame apa Screws set A aside in Step 7 9 Snap in Housing Pull existing wiring
4. serve le droit de modifier leurs caract ristiques sans pr avis Les garanties sur les produits Greenheck particuliers se trouvent a greenheck com sous les onglets des produits et dans la biblioth que Library sous Warranties Le catalogue SP CSP ventilateurs SP CSP de Greenheck fournit des informations suppl mentaires sur le mat riel les performances des ventilateurs les accessoires disponibles et caract ristiques techniques La publication AMCA 410 96 Safety Practices for Users and Installers of Industrial and Commercial Fans fournit des informations suppl mentaires sur la s curit Cette publication peut s obtenir aupr s d AMCA International Inc a www amca org A GREENHECK Building Value in Air T l phone 715 359 6171 T l copie 715 355 2399 e Pi ces d tach es 800 355 5354 e Courriel gfcinfo greenheck com Site Web www greenheck com 12 Ventilateurs d extraction de plafond SP R v 3 novembre 2013 Copyright 2013 Greenheck Fan Corporation
5. glage de temporisation TIME pour faire pointer la fl che sur la valeur souhait e en minutes Les commandes ajustables par l utilisateur se trouvent dans l un des coins du caisson derri re la grille 50 60 30 45 es 30 80 5 60 CFM TIME Commandes ajustables par l utilisateur SP80 70 30 9 45 se 30 IIO 5 60 CFM TIME Commandes ajustables par l utilisateur SP110 Ventilateurs d extraction de plafond SP EE AVERTISSEMENT Avant tout entretien ou nettoyage de l appareil couper l alimentation sur le tableau lectrique et verrouiller le dispositif de sectionnement pour emp cher toute mise sous tension accidentelle Si le dispositif de sectionnement ne peut pas tre verrouill attacher un moyen de mise en garde bien visible tel qu un panonceau au tableau lectrique Nettoyage et entretien Pour nettoyer Pour assurer un fonctionnement silencieux et efficace une longue dur e de service et une apparence attrayante retirer la grille et passer l int rieur de l appareil l aspirateur quip d une brosse poussi re Le moteur est lubrification permanente et ne n cessite aucune huile suppl mentaire Si les paliers du moteur font un bruit inhabituel ou excessif changer le module de commande et le moteur D pannage Probl me Solution potentielle Le ventilateur ne fonctionne pas Voir s il y a un fusible ou un disjoncteur ouvert dans le tableau lectrique de l
6. immeuble V rifier que les deux 2 fiches de raccordement du moteur et de la commande sont fermement en place V rifier que la turbine tourne librement Le ventilateur fonctionne de fa on irr guli re V rifier que la turbine est solidement fix e l arbre du moteur et que les deux tournent librement Le ventilateur semble bruyant V rifier que le registre antirefoulement dans le connecteur de gaine du ventilateur pivote librement Il est possible que les vis utilis es pour fixer la gaine au connecteur de gaine emp chent le registre de s ouvrir V rifier que le registre antirefoulement dans le chapeau mural o de toiture pivote librement Ces registres sont parfois peints en position ferm e par erreur o obstru s par des d bris d oiseaux ou d insectes Le ventilateur ne ventile pas correctement la pi ce Pour la ventilation ponctuelle l interrupteur g n ral et le s lecteur de mode doivent tre tous deux en position de marche pour permettre au ventilateur de fonctionner au d bit d air certifi Pour obtenir une ventilation ponctuelle suivie d une ventilation continue augmenter le r glage de temporisation ajustable par l utilisateur TIME Pour obtenir une ventilation continue augmenter le r glage de d bit d air ajustable par l utilisateur CFM Notre engagement Dans le cadre de son engagement a l am lioration continue de ses produits Greenheck se r
7. into Housing as it is inserted into Mounting Frame 10 Attach Ducting and Duct Connector Screw from Parts Bag 4 Pull existing into Housing Insert tab into slot inside Housing 4 Ducting Tape OM A SP Ceiling Exhaust Fans BEJ 6 to 4 Reducer provided in select models Retrofit Installation 11 Install Knockout Plate Connect Wires and Install Wiring Panel e Use proper UL approved connectors to secure wiring to the Knockout Plate provided in Parts Bag e Connect wires as shown in wiring diagram Attach cable clamp to Knockout Plate Knockout Plate mounts to inside of Housing and may be 7 oriented as desired Screw set aside in Screw from Parts Bag BLK Adjustable Level MASTER ON OFF MODE SWITCH SELECT SWITCH SWITCH BOX BLACK RED WHITE GROUND green or bare RECEPTACLE MASTER MODE ON OFF SELECT SWITCH SWITCH SWITCH BOX KNOCKOUT PLATE purchase separately 120 VAC LINE IN 10 SP Ceiling Exhaust Fans Retrofit Installation 12 Insert and Secure Blower Assembly Operation To Turn Fan ON Turn the master switch ON e Fan will run at the certified airflow rate if the mode select switch is ON e Fan will run at the user adjustable airflow rate if the mode select switch is OFF To Use Fan Time Delay Airflow Rate Change 1 Turn th
8. respectez toutes les informations de s curit Toute infraction ces instructions peut provoquer des blessures corporelles et des dommages mat riels Mod le SP1 0 SP80 Installation facile aussi bien dans les constructions Pi ces de rechange N Greenheck Num ro de Description ep aa Pi ce 1 435100 B ti de montage 2 435101 Plaquette d fon able et vis 3 435102 Caisson 4 435109 Panneau faisceau de c blage 5 435104 Commande et moteur SP80 435105 Commande et moteur SP110 6 435106 Connecteur de gaine 6 po T 435107 R ducteur 6 po 4 po mod le SP80 seulement 8 435108 Turbine 9 435116 Volute i 10 435110 Grille comprend rep 11 11 435111 Ressort de grille 2 requis Table des mati res Mises GI gard 5sssrut erssemmaersssamelhsss eines reteeiiate 2 FONCTIONNEMENT 2c cccsiscceceseecsceeectescccneneeszacezabaresce 11 Installation typique eeeeeeeeeeeeeeeeeeeeeeeeteeeeeeeeeeeees 2 Nettoyage et entretien 12 Installation dans une construction neuve 3 D pannage sisi 12 Installation de r novation s es 7 Notre engagement 12 A Ventilateurs d extraction de plafond SP EI AVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURE CORPORELLE RESPECTER CE QUI SUIT 1 Utiliser cet appareil exclusivement comme pr vu par le fabrican
9. Document 99045143B I GREENHECK Model SP110 SP80 ee Multi Speed Building Value in Air Ceiling Exhaust Fan Installation Operation and Maintenance Manual Please read and save these instructions for future reference Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Model SP1 1 O0 SP80 Easy installation in both new construction and retrofit Service Parts Key Greenheck No Part No 1 435100 Mounting Frame Description 2 435101 Knockout Plate amp Screws 3 435102 Housing 4 435109 Wiring Panel Harness Assembly 435104 Control Assembly amp Motor SP80 435105 Control Assembly amp Motor SP110 6 435106 Duct Connector 6 7 435107 6 to 4 Reducer model SP80 only 8 435108 Blower Wheel 9 435116 Scroll Assembly 10 435110 Grille Assembly includes 11 11 435111 Grille Spring 2 req d Table of Contents Warnings and Cautions 2 OPO T AION vests seed cede ccs etct ee ere ete ri tenne rares st 11 Typical Installations ss sement 2 Cleaning and Maintenance 12 New Construction Installation cccccceeeeeeeeeeeeees 3 TROUDIGSNOOLING oi ciccvctevasticassdedscesienedceee
10. N PLAQUETTE D FON ABLE acheter s par ment ENTR E ALIM 120 VCA B Ventilateurs d extraction de plafond SP Jj Installation dans une construction neuve 6 Ins rer le masque et finir le plafond e Poser le mat riau de plafond e D couper sur le pourtour du caisson ae Le masque prot ge l appareil durant la construction L enlever avant de poser la grille 7 Poser la grille REMARQUE Voir Fonctionnement a la page 11 Nettoyage et entretien et D pannage a la page 12 6 Ventilateurs d extraction de plafond SP Installation de r novation Outillage n cessaire Mat riels n cessaire Visseuse lectrique embout Phillips e Ruban d tanch it pour les raccordements de gaine Tournevis Phillips R gle e La gaine rigide existante n cessitera l ajout d un Tournevis plat Crayon courte longueur de gaine flexible Pince Scie pour cloison s che e C blages et fournitures lectriques conformes au code de l lectricit en vigueur Marteau panne fendue ou Pince d nuder levier Coupe c ble Couteau utilitaire 1 D baller D tacher le masque de l emballage Voir l tape 12 Enlever la fiche d instruction Le sachet de pi ces contient la plaquette d fon able et six 6 vis 2 Couper l alimentation lectrique AVERTISSEMENT Avant de d poser le ventilat
11. e dispositif de r gulation de vitesse semi conducteurs Pose admissible au dessus d une baignoire ou d une douche sous r serve de raccordement un circuit de d rivation protection GFCI disjoncteur diff rentiel Cet appareil doit tre raccord la terre ISOLAN Placer autour et au dessus du caisson de v CAISSON DE ATTENTION utiliser pour la ventilation g n rale uniquement Ne pas utiliser pour l aspiration de mati res et vapeurs dangereuses ou explosives 1 Ce produit est con u pour tre pos dans des plafonds inclin s jusqu une pente de 12 12 angle de 45 degr s Le connecteur de gaine doit tre tourn vers le haut NE PAS MONTER CE PRODUIT DANS UN MUR Pour viter d endommager les paliers du moteur et les bruits et ou d s quilibres de rotor tenir le syst me moteur l abri des projections de mat riaux pour cloison s che des poussi res de construction etc Pour plus de renseignements et exigences lire l tiquette de sp cifications sur le produit ATTENTION NE PAS UTILISER DANS LES ZONES DE CUISINE Installation typique e L installation est identique pour Ii Solives Poutres en Fermes e Convient aux plafonds construits en 2 po x 8 po e Position du ventilateur infiniment ajustable entre des solives espac es de 35 6 cm 61 cm 14 po 24 po entre centres T CHAPEAU DE TOITURE entilateur a registre int gr
12. e master switch ON 2 Turn the mode select switch ON fan will run at the certified airflow rate 3 When the mode select switch is turned OFF fan will continue to run at the certified airflow rate until the user adjustable time delay has elapsed and then will automatically change to the user adjustable airflow rate To Set the User Adjustable Airflow Rate Using a small flat blade screwdriver carefully rotate the CFM adjustment until the arrow points to the desired airflow rate A Q 2 3 Screws from Parts Bag If ceiling repairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille To Set the User Adjustable Time Delay Using a small flat blade screwdriver carefully rotate the TIME adjustment until the arrow points to the desired time delay shown in minutes The user adjustable controls are located in one corner of the Fan Housing behind the Grille 50 60 30 45 30 80 5 60 CFM TIME SP80 User adjustable controls 70 30 0 45 Sey 30 110 5 60 CFM TIME SP110 User adjustable controls SP Ceiling Exhaust Fans EE WARNING Cleaning and Maintenance Before servicing or cleaning unit switch power off To Glean at service panel and lock the service disconnecting For quiet and efficient operation long life and attractive means to prevent power from being switched on appearance re
13. eur existant couper l alimentation sur le tableau lectrique et verrouiller le dispositif de sectionnement pour emp cher toute mise sous tension accidentelle Si le dispositif de sectionnement ne peut pas tre verrouill attacher un moyen de mise en garde bien visible tel qu un panonceau au tableau lectrique 3 Agrandir l ouverture dans le plafond et d poser le ventilateur existant 30 5 cm 12 po h f 27 9 cm 11 po parall lement aux solives Gaine et c blage existants 1 laiss s en place 4 Examiner le cablage SJ aaa A Sr Examiner le c blage existant pour v rifier qu il est en bon tat Si des dommages sont constat s NE PAS POURSUIVRE L INSTALLATION de ce produit Faire r parer par une personne qualifi e B Ventilateurs d extraction de plafond SP Installation de r novation 5 D poser la soufflante Conserver le panneau de cablage J 2 Plier les quatre pattes D poser les vis du bati de montage et les conserver Em Ventilateurs d extraction de plafond SP A Installation de r novation 8 Fixer le bati de montage Vis conserv es l tape 7 9 Enclencher le caisson Tirer le c blage existant dans le caisson lorsqu
14. il est ins r dans le b ti de montage 10 Attacher la gaine et le connecteur de gaine a eViS du sachet de pi ces Tirer la gaine existante dans le caisson Gaine de 4 po Ins rer les pattes dans la fente l int rieur du caisson Ruban Ruban d tanch it d tanch it Yo ro R ducteur 6 po 4 po fourni avec certains mod les Ventilateurs d extraction de plafond SP 9 Installation de r novation 11 Poser la plaquette d foncable raccorder les cables et poser le panneau de cablage e Utiliser des connecteurs homologu s UL qui conviennent pour attacher le cable la plaquette d fon able fournie dans le sachet de pi ces e Raccorder les fils comme indiqu sur le sch ma de c blage Attacher le serre cable la plaquette d fon able La plaquette se monte sur l int rieur du caisson et peut tre orient e selon les besoins Vis conserv e l tape 6 Raccorder les fils ENERAL M A INTERRUPTEUR G BOITE DE COMMUTATION APPAREIL NOIR ROUGE BLANC TERRE vert ou d nud PRISE INTERRUPTEUR GENERAL S LECTEUR BO TE DE DE MODE COMMUTATION PLAQUETTE D FON ABLE acheter s par ment ENTR E ALIM 120 VCA 10 Ventilateurs d extraction de plafond SP Installation de r novation 12 Mettre la soufflante en place et la fixer
15. ilities Ducted fans must always be vented to the outdoors Do not use this fan with any solid state speed control device Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit This unit must be grounded INSULATION Place around and over Fan Housing FAN HOUSING Seal gaps around 7 Housing Purchase separately 2 SP Ceiling Exhaust Fans Seal duct joints with CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 1 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Please read specification label on product for further information and requirements CAUTION NOT FOR USE IN A COOKING AREA Typical Installation e Installation is the same for Id Joists Joists Trusses e Fits in 2 x 8 ceiling construction e Infinitely adjust the fan position between joists from 14 to 24 on center ROOF CAP AN lt lt with built in damper dun LSS See SA Keep duct runs short ROUND tape ELBOWS with built in damper New Construction Installation To
16. move Grille and vacuum interior of unit accidentally When the service disconnecting means with a dusting brush attachment cannot be locked securely fasten a prominent The Motor is permanently lubricated and never needs warning device such as a tag to the service panel oiling If the motor bearings are making excessive or unusual noises replace the Control Assembly and Motor Troubleshooting Problem Potential Solution Check for an open fuse or circuit breaker in the building s service panel Check that the two 2 plug in connections for the Motor and the Control are seated The fan does not run firmly in place Check that the Blower Wheel spins freely The fan runs erratically Check that the Blower Wheel is firmly attached to the Motor shaft and both spin freely Check that the back draft damper in the fan s Duct Connector pivots freely Screws used to attach the duct to the Duct Connector may be preventing the damper from opening The fan seems noisy Se a a Check that the back draft damper in the wall or roof cap pivots freely These dampers are sometimes mistakenly painted shut or obstructed by bird and insect debris For spot ventilation turn both the master switch and the mode select switch ON to enable the fan to run at the certified airflow rate The fan does not properly For spot ventilation followed by continuous ventilation increase the TIME setting of the ventilate the ro
17. mstpeaavetecieenc 12 Retrofit Installation 7 Our COMMEN sisine adai aiaia 12 A SP Ceiling Exhaust Inline Fans El WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden ut
18. ols needed Materials needed Power screwdriver with a Phillips bit e 6 round metal ducting recommended for best Phillips screwdriver performance Use of other ducting is acceptable but Flathead screwdriver may impact performance Pliers e Roof cap or wall cap built in damper recommended Wire insulation stripper e Tape to seal duct connections Wire cutter e Electrical wiring and supplies per local code requirements 1 Remove Packaging Punch out Mask from packaging See Step 6 Remove Instruction Sheet Parts Bag holds Knockout Plate and six 6 screws 2 Install Mounting Frame A SP Ceiling Exhaust Fans JE New Construction Installation 3 Snap in and Secure Housing Position Housing between joists and crimp channel on both sides of Mounting Frame amp Poor to lock Housing in place Screws from Parts Bag Do not crimp Housing 4 Attach Duct Connector and Ducting Screw from a 2 Parts Bag Top and bottom flanges go outside Housing Insert tab into slot p pas Housing 4 SP Ceiling Exhaust Fans New Construction Installation 5 Connect Wires and Install Knockout Plate e Run 120VAC electrical wiring to the installation location e Use proper UL approved connectors to secure wiring to the Knocko
19. om user adjustable time delay For continuous ventilation increase the CFM setting of the user adjustable airflow rate Our Commitment As a result of our commitment to continuous improvement Greenheck reserves the right to change specifications without notice Specific Greenheck product warranties are located on greenheck com within the product area tabs and in the Library under Warranties Greenheck SP CSP catalog provides additional information AMCA Publication 410 96 Safety Practices for Users and describing the equipment fan performance available Installers of Industrial and Commercial Fans provides accessories and specification data additional safety information This publication can be obtained from AMCA International Inc at www amca org A GREENHECK Building Value in Air Phone 715 359 6171 Fax 715 355 2399 e Parts 800 355 5354 e E mail gfcinfo greenheck com Website www greenheck com A SP Ceiling Exhaust Fans Rev 3 November 2013 Copyright 2013 Greenheck Fan Corporation 99045143B I GREENHECK Mod le SP110 SP80 se Ventilateur d extraction de plafond multivitesse Building Value in Air j Manuel d installation d utilisation et d entretien Veuillez lire ces instructions et les conserver pour consultation ult rieure Lisez avec attention avant d essayer d assembler d installer d utiliser ou d entretenir le produit d crit Pour votre protection et celle des autres
20. t En cas de questions communiquer avec le fabricant l adresse ou au num ro de t l phone figurant dans la garantie Avant tout entretien ou nettoyage de l appareil couper l alimentation sur le tableau lectrique et verrouiller le dispositif de sectionnement pour emp cher toute mise sous tension accidentelle Si le dispositif de sectionnement ne peut pas tre verrouill attacher un moyen de mise en garde bien visible tel qu un panonceau au tableau lectrique La pose et le c blage lectrique doivent tre effectu s par des personnes qualifi es en conformit avec les codes et normes en vigueur y compris pour la r sistance au feu du b timent Une quantit d air suffisante est n cessaire pour la bonne combustion et l extraction des gaz br l s par le conduit d vacuation chemin e d appareils combustible afin d viter le refoulement Veiller suivre les indications du fabricant du mat riel de chauffe les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et la r glementation en vigueur Lors de la d coupe ou du per age de murs ou plafonds ne pas endommager les c bles lectriques et autres conduites masqu es Les caissons d extraction gaine doivent toujours tre vacu s vers l ext rieur Ne pas utiliser ce ventilateur avec un quelconqu
21. tre les solives et pincer le profil des deux c t s du bati de montage pour bloquer le caisson en place Ne pas pincer le caisson Vis du sachet a 2 de pi ces A n Placer les brides sup rieure et inf rieure l ext rieur du caisson XY Ins rer les pattes dans la fente l int rieur du caisson Ruban Ruban d tanch it d tanch it R ducteur 6 po 4 po fourni avec certains mod les a Ventilateurs d extraction de plafond SP BA Installation dans une construction neuve 5 Raccorder les cables et poser la plaquette d fon able e Tirer un cable d alimentation 120 Vc a jusqu a l emplacement de l installation e Utiliser des connecteurs homologu s UL qui conviennent pour attacher le c ble la plaquette d fon able fournie dans le sachet de pi ces e Raccorder les fils comme indiqu sur le sch ma de c blage Attacher le serre cable la plaquette d fon able La plaquette se monte sur l ext rieur du caisson et peut tre orient e selon les besoins 2 Raccorder les fils sachet de pi ces NR NR Niveau r glable INTERRUPTEUR GENERAL M A nominal VENTILATEUR ALIM TER TER Z ss ep ee ee a S A a ee ee ee J BO TE DE COMMUTATION APPAREIL NOIR ROUGE BLANC TERRE vert ou d nud PRISE INTERRUPTEUR a aoe SELECTEUR BO TE DE DE MODE COMMUTATIO
22. ut Plate provided in Parts Bag e Connect wires as shown in wiring diagram Attach cable clamp to Knockout Plate Knockout Plate mounts to outside of Housing and may be oriented as desired e yw Screw from Parts Bag BLK BLK Adjustable Level MASTER ON OFF SWITCH MODE SELECT Level SWITCH LINE IN GRD GRD a J SWITCH BOX UNIT BLACK RED WHITE GROUND green or bare RECEPTACLE MASTER MODE ON OFF SELECT SWITCH SWITCH SWITCH BOX KNOCKOUT PLATE purchase separately 120 VAC LINE IN A SP Ceiling Exhaust Fans J New Construction Installation 6 Insert Mask and Finish Ceiling e Install ceiling material e Cut out around Housing a lt lt Um Mask protects unit during construction Remove before installing Grille 7 Install Grille NOTE See Page 11 for Operations Page 12 for Cleaning and Maintenance and Troubleshooting 6 SP Ceiling Exhaust Fans Retrofit Installation Tools needed Materials needed Power screwdriver with a Phillips bit e Tape to seal duct connections Phillips screwdriver Ruler e Existing rigid duct will require the addition of a short Flathead screwdriver Pencil eng oF rere dugi Pliers Drywall saw Electrical wiring and supplies per local code requirements Wire insulation stripper Claw hammer or pry bar