1. N O contact electric release OR N C contact alarm e common N O contact alarm Input voltage DC or AC 12V or 24V List Request to enter input Without jumper without clock With jumper with clock M Common P1 et P2 P2 Request to enter input 5 a E Door contact N C Door closed and N O Door open EE Reader activation imput N O reader enabled and N C reader disabled M Common E and M or E and L aa RS485 Bus All the A must be connected together in daisy chain B RS485 Bus All the B must be connected together in daisy chain Terminal block 3 points Piggyback board LED gt Red color en LED gt Green color Sy Buzzer STAND ALONE MODE CENTRALIZED MODE TELACCESS TERENA Bf ie Dipswitch address set up vai UGM UGL Dip4 ON wih UGP 40 Aco PDN345BUSPROX DIP SWITCH adressing Front plate Address programming during installation Reader 1 Dip4 OFF Reader 2 Reader 3 ST1 Programming jumper Reader 4 ST1 Programming jumper Normal a I JB 123 Normal As standard Installation KL d cdvi com cdvigroup com 15 16 Programming the illumination AO Enter the illumination time in seconds or 00 for a permanent illumination 1 beep OK 4 beeps Error cdvi com cdvigroup com Programming the output format Enter 1 Wiegand 26 bit format 2 Standard format 3 ISO Track 2 format 1 beep OK 4 beeps Error Prog
2. Signalisation gt couleur verte Buzzer MODE AUTONOME TELACCESS Programmation de l adresse par dipswitch Dip4 ON Adressage DIPSWITCH MODE CENTRALIS TERENA qe UGM UGL TE UGP 40 PDN345BUSPROX Programmation de l adresse par installation Lecteur 1 Dip4 OFF ST1 Cavalier de programmation Lecteur 2 Lecteur 3 Lecteur 4 im amp 2 ST1 Cavalier de programmation 123 123 123 Normal Config usine Installation cdvi com cdvigroup com 5 6 Programmation de l clairage Tapez la dur e de commande en secondes ou OO pour un clairage permanent 1 bips OK 4 bips Erreur cdvi com cdvigroup com Programmation du format de sortie Tapez 1 Wiegand 26 bits 2 Format Standard 3 Format ISO Track 2 1 bips OK 4 bips Erreur 2 bips sonores Programmation du nombre de termes Tapez 4 5 ou 6 pour d finir le nombre de termes 1 bips OK 4 bips Erreur 2 bips sonores sur ON pour entrer en programmation ON y Programmation du signal sonore Tapez 0 suppression du bip des touches 1 Autorisation du bip des touches 1 bips OK 4 bips Erreur i Basculez le switch Programmation du mode d cimal ou h xad cimal Tapez 0 mode d cimal 1 mode h
3. d passer la valeur du produit La responsabilit de CDVI ne peut tre engag e aupr s de l acheteur installateur client final ou qui que ce soit lors de dommages cons cutifs des imperfections ou mauvais fonctionnement du produit Cette garantie prend effet la date d enregistrement du produit aupr s de CDVI partir de l instant ou la date d enregistrement est d ment compl t e dans la limite d un mois apr s la date de livraison au client final Pour obtenir les d tails complets de cette garantie et enregistrer votre vos produit s pour b n ficier de cette Garantie Vie limit e Veuillez compl ter la carte d enregistrement pr sente dans la boite du produit et nous la retourner par email ou par courrier l adresse de l entit CDVI la plus proche ou vous enregistrer en ligne l adresse www cdvigroup com Les contacts des entit s CDVI sont accessibles en ligne l adresse www cdvigroup com ou au dos de la notice d installation EXCLUSIONS DE LA GARANTIE A l EXCEPTION DES POINTS EVOQUES PRECEDEMMENT CDVI N APPLIQUE AUCUNE GARANTIE NI DELIBEREE NI TACITE A TOUS LES PROBLEMES INCLUANT LE CONDITIONNEMENT LE TRANSPORT LEUR COMMERCIALISATION OU LES CONDITIONS D UTILISATIONS PARTICULIERES 12 NOTES Voir conditions de garantie vie limit e cdvi com cdvigroup com 11 Output formats Wiegand Standard format ISO Track 2 format m Back lighted Material Cast aluminium alloy x Visu
4. du clavier AO Un bip est mis RRENA i Tapez la dur e de commande en secondes 10 pour 10 secondes 99 pour 99 secondes ou tapez 00 pour obtenir un clairage permanent Un bip de validation est mis 3 Basculez le switch sur OFF Deux bips sont mis pour confirmer of le retour au mode normal de fonctionnement R f rez vous a la proc dure d entr e en programmation en d but de chapitre Basculez le switch sur OFF Basculez le switch sur OFF i OFF Un bip est mis Tapez 1 pour une sortie au format Wiegand 26 bits Tapez 2 pour une sortie au format Standard Tapez 3 pour une sortie au format ISO Track 2 Un bip de validation est mis Deux bips sont mis pour confirmer E le retour au mode normal de fonctionnement D PROGRAMMATION DU NOMBRE DE TERMES Entrez en programmation Tapez A2 pour la saisie du nombre A2 de termes des codes Un bip est mis Tapez 4 5 ou 6 pour le nombre de termes Un bip est mis pour confirmer la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement cdvi com cdvigroup com 7 r tro clair Wiegand E PROGRAMMATION DU SIGNAL SONORE Le signal sonore est toujours audible en programmation Par d faut lors de la composition du code aucun bip touche
5. n est audible Il est possible d autoriser les bips touches en faisant comme suit 1 Entrez en programmation 2 Tapez A3 Un bip est mis Den F Tapez 0 pour supprimer les bips touches pendant la composition du code Tapez 1 pour autoriser les bips touches pendant la composition du code Un bip est mis pour confirmer la programmation 3 Basculez le switch sur OFF Deux bips sont mis pour confirmer E le retour au mode normal de fonctionnement F PROGRAMMATION DU MODE D CIMAL OU HEXADECIMAL 1 Entrez en programmation 2 Tapez A4 pour la saisie du mode Un bip est mis Tapez 0 pour le mode d cimal ou 1 pour le mode hexad cimal Un bip est mis pour confirmer la programmation 3 Basculez le switch sur OFF l Si Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement G COMMANDE EXT RIEURE DU BUZZER Le buzzer du clavier peut tre command ext rieurement par une centrale Il suffit d appliquer un signal logique sur l entr e Buzzer du GALEOW Fil marron Buzzer actif Buzzer inactif OV 9 FORMAT DE SORTIE WIEGAND 26 BITS CLOCK DATAO 2ms 1 logique 2ms R f rez vous la proc dure d entr e en programmation en d but de chapitre cdvi com 8 cdvigroup com MANUEL D INSTALLATION GALEOW Digicode r tro clair Wiegand ee
6. power supplies A power supply independent of the central controller is necessary for the GALEOW There are two suitable power supplies for this Digicode keypad ARD12 or BS60 Installation recommendations To protect the installation remember to install the varistor in parallel on the locking system power supply side install a 120 ohm resistor between A and B on the last BUS RS485 door controller mounting screw M4x30 T20 Torx spanner S5 plastic anchor INSTALLATION MANUAL GALEOW Wiegand illuminated keypad 4 MOUNTING After having verified that the fitting kit is complete and having made the connection of the GALEOW coded keypad with or without the door controller depending on whether you use a central controller or panel you can proceed with the final installation of the product Collect up the necessary tools drill screwdriver measuring tape etc and follow the GALEOW fitting instructions Confirm the distance between the GALEOW and central controller or door controller see page 3 Reminders and recommendations Mark out the locations and drill two mounting holes 5 mm drill bit and minimum depth 35 mm as well as the hole for the keypad s electric cable Insert the GALEOW electric cable through its cable hole and attach it to its support from above with the top hook Fix the GALEOW on its support using the TORX screw and its special tool elbow m
7. termes 00012345 En 6 termes 00123456 Pr sence Clock IPL LU UL LP LPL LLLP Ld Pot D lt Time us 25 50 OF BIT TIME Chaque caract re est compos de 5 bits 4 bits de donn es 1 bit de parit Caract res Parite a a a E C Me ss o M y iosas Hatt He ihe t i a a cdvi com 10 cdvigroup com MANUEL D INSTALLATION GALEOW Digicode r tro clair Wiegand E E eS O aaa Eee ee eS eS SS O E U E T 8 CONDITIONS DE GARANTIE VIE LIMIT E EXTRAIT Les soci t s CDVI garantissent que ce produit est d pourvu de tout vice cach tant dans les mat riaux que dans sa fabrication la condition qu il soit install conform ment aux pr conisations du fabricant et qu il n y ait pas eu d interventions ou de modifications sur le produit La responsabilit de CDVI se limite la r paration ou l change du produit CDVI n assume aucune responsabilit concernant les dommages sur les biens ou les personnes Un produit reconnu d fectueux par CDVI doit tre retourn au service apr s vente de CDVI apr s l obtention du num ro d autorisation de Retour de Produit s D fectueux RMA La responsabilit de CDVI se limite la r paration ou au remplacement d un produit ou pi ces d fectueuses en ses ateliers L une ou l autre de ces interventions sont d finis par le service apr s vente de CDVI Le pr judice imputable CDVI ne saurait en aucun cas
8. the entire liability can not exceed the purchase price of the product The CDVI local country contact details can be found on line by visiting www cdvigroup com or on the back cover of the installation manual DISCLAIMER OF WARRANTY EXCEPT AS STATED ABOVE CDVI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF ITS PRODUCTS THE TRANSPORTATION THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE 12 NOTES Refer to Limited Lifetime Warranty conditions cdvi com cdvigroup com 21 ire Wiegand cdvi com 22 cdvigroup com MANUEL D INSTALLATION GALEOW Digicode r tro clair Wiegand cdvi com cdvigroup com 23 Reference G0301FR0266V06 Extranet EXE CDVI_IM GALEOW CMYK A5 EN FR 05 Manufacturing Access Control since 1985 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 Ge 8 NOIRS ER OS NN EAU ONE CDVI Group FRANCE Headquarter Si ge social Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBERICA SPAI
9. Alimentation Pour l alimentation il y a deux modes possibles 12 V DC uniquement Configuration usine Coupez le strap oS 12 V AC ou 24 V DC cdvi com 4 cdvigroup com il D691 Si vous ne souhaitez pas de gestion de l etat porte Relier E et M INTBUSW CD ri LI U D i Cable blindage Vers d autres contr leur de portes INTBUSW MANUEL D INSTALLATION GALEOW Digicode r tro clair Wiegand Sans cavalier sans clock Avec cavalier avec clock INTBUSW Contr leur de porte Bornier 5 points Carte m re Alimentation 12 Alimentation pa foia O Clock Data 1 Bornier 16 points Carte m re Contact N F porte Ventouse Contact commun Alimentation T Contact N O porte G che Contact N F alarme Contact commun T Contact N O alarme Alimentation DC ou AC 12 V ou 24 V DC Bouton poussoir int rieur Masse commune P1 et P2 Bouton poussoir ext rieur Contact fermeture porte N F Porte ferm e et N O Porte ouverte Contact autorisation lecture du badge N O autoris e et N F interdite Masse commune E et M ou E et L Bus RS485 tous les A doivent tre reli s entre eux sous la forme d une cha ne Bus RS485 tous les B doivent tre reli s entre eux sous la forme d une cha ne Bornier 3 points Carte fille 7 Signalisation gt couleur rouge
10. GALEOW Wiegand illuminated keypad Interface The output format is 26 bit Wiegand Signals DATA DATAO and CLOCK Output signal in open collectors pull up of 2 2K in 5V 26 bit hexadecimal output format The frame is made of 26 bit and built as follow First parity 1 bit even parity for the first 12 bit User Code 3 half of a byte represent the code entered Each byte is transferred from bit 7 to bit O Second parity 1 bit odd parity for the last 12 bit Even parity on bit 2 bit13 Data 24 bits Odd parity on bit 14 bit 25 KEYPAD CODE Example with a 5 Digit keypad code 71375 Then B Example with a 6 Digit keypad code 671375 Then B Parity 1 0 if the number of 1 in bit 2 to bit 13 is even 1 if the number of 1 in bit 2 to bit 13 is odd Parity 2 0 if the number of 1 in bit 14 to bit 25 is odd 1 if the number of 1 in bit 14 to bit 25 is even 10 STANDARD FORMAT This format is owned by Standard This format is compatible with other Standard products Contact us cdvi com cdvigroup com 19 SS start sentinel gt Hex B ES end sentinel gt Hex F LRC Ou Exclusif de tous les caract res de la trame including SS and ES The code length is set at 8 digits In 4 digits gt 00001234 In 5 digits gt 00012345 In 6 digits gt 00123456 Pr sence Clock IP LEU LU LLP LPL LLL LP Ld pot lt b lt Time eae 25 50 OF BIT TI
11. ME Each digit is made of 5 bits 4 bits data 1 bit parity Characters Parity IE TE eee eee SE EE EN EE i a a 4 cdvi com 20 cdvigroup com INSTALLATION MANUAL GALEOW Wiegand illuminated keypad 8 LIMITED LIFETIME WARRANTY EXTRACT CDVI warrants this product to be free from defects in material and workmanship when it has been installed in accordance with the manufacturer s instructions and has not been modified or tampered with Only product recognized by CDVI to be defective should be returned under these warranty terms if accompanied by an RMA Return Material Authorization Number provided by CDVI CDVI at its option shall repair or replace the defective product at CDVI premises or at any CDVI approved service center This warranty does not cover any damage due to accident misuse abuse or negligence This warranty is valid only if the product is registered within 1 month from delivery to the final costumer To obtain full details of this warranty and to register the product to commence the Limited Lifetime Warranty complete the enclosed registration card and return it either by e mail or post to the relevant CDVI address or completion of the on line registration at www cdvigroup com Repair or replacement of the defective product is the exclusive remedy CDVI shall not be liable for any incidental or consequential damages arising from any defect in or malfunction of its product In no event
12. N PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 CDVI MAROC Phone 212 0 5 22 48 09 40 Fax 212 0 5 22 48 34 69 d e information contained within this document photos drawing features specifications and dimensions could be perceptibly different and can be changed without prior notice CDVI SWEDEN SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 Fax 46 0 31 748 09 30 CDVI UK UNITED KINGDOM IRELAND Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86 Toutes les informations mentionn es titre indicatif sur le pr sent document photos dessins caract ristiques techniques et dimensions peuvent varier et sont susceptibles de modifications sans notification pr alable
13. al and audible signalling Surface mounting a Small size m Torx screw assembly a Totally waterproof cast body s Dimensions Lx W x D 110 x 75 x 15 mm Rear switch on the GALEOW for entry to and exit from programming mode Permanent E2PROM memory back up a Number of digits 4 5 or 6 Operating voltage 12 V DC Consumption 100 mA max 2 NOTES AND RECOMMENDATIONS Wiring reminder In the case of direct connection to the CT V900 A CENTAUR central controller or one of the LINKNET door controllers the GALEOW must be installed within a maximum distance of 50 m In other cases the distance between the GALEOW and the INTBUSW door controller must be within a maximum of 50 m and the distance between the central controller or panel and the last INTBUSW door controller may be up to 1200 m maximum Take care not to pass your wires close to High voltage cables e g 230 V AC Recommended cables 2 pairs of cables 4 strand SYT1 8 10ths Shielded cables AWG 20 3 MOUNTING KIT Torx screw Varistor M4x10 cdvi com 12 cdvigroup com HIGH RESISTANCE TO VANDALISM OQOQD X WEEE amp RoHS I 164 C CE Certification UW 33 Envrionmental tests a vibrations 25 C to 70 C Fitting To optimise the mounting of the GALEOW and to combat attempted tampering it should be fitted on a flat surface Recommended
14. ale screw spanner Apply the screw cap to complete the installation of this product Insert the 2 plastic anchors in the holes Mount the back plate of the GALEOW on your chosen support using the supplied M4x30 mounting screws 0 SOS SOC Controller terminal wirings LT20PB LT20AC PROMI1000 GALEOW Outputs CT V900 A LT20PBIP LT201P veas PROMI1000pc PROMI500 DGPROX Input voltage 12V 12VDC 12VDC 12VDC CRC CIRE p piee EN EE EE EE ES Cas Lee EEE DM rd el eT cdvi com cdvigroup com 13 GALEOW GALEOW ST1 44 30 26 White 44 Green 30 Blue 26 Red 44 Black s0 26 Grey x erac v au cok ereen oeo M Magnet v Varistor Power supply Two different configurations are possible 12VDC only As standard Cut the strap AN 12VAC or 24VDC cdvi com 14 cdvigroup com il INTBUSW und i QOOU D691 Shielded cable To other door controllers INTBUSW Door contact not used Connect E and M INSTALLATION MANUAL GALEOW Wiegand illuminated keypad INTBUSW Door controller Terminal block Motherboard Input voltage Ey Input voltage Pa fowo SSS S S Clock Data 1 Terminal block Motherboard N C contact eletromagnetic lock Common contact power supply
15. e SSS Sees Sa eee SSS Interfa age La communication s effectue par une liaison de type Wiegand 26 bits Format 26 bits hexad cimal Signaux DATA1 DATAO et CLOCK Sortie des signaux en collecteur ouvert avec pulls up interne de 2 2K au 5V La trame est constitu e d une totalit de 26 bits et se d compose comme suit 1 parit 1 bit parit paire des 12 bits suivants Code clavier 3 mots d un octet repr sentant le code tap Chaque mot est transmis bit de poids fort en premier 2 me parit 1 bit parit impaire des 12 bits pr c dents Parit paire sur bit 2 bit13 Donn e 24 bits Parit impaire sur bit 14 bit 25 KEYPAD CODE Tessar rower fo fo ros aman mer 0 o 0 Lama rene o a CORC Parit 1 0 si le nombre de 1 dans bit 2 bit 13 est paire 1 si le nombre de 1 dans bit 2 a bit 13 est impaire Parit 2 0 si le nombre de 1 dans bit 14 bit 25 est impaire 1 si le nombre de 1 dans bit 14 bit 25 est paire 10 FORMAT DE SORTIE FORMAT STANDARD Le GALEOW fonctionne sous ce format propri t de l entreprise avec certaines centrales ou platines de la gamme Standard nous consulter cdvi com cdvigroup com 9 SS Sentinelle de d but gt Hex B ES Sentinelle de fin gt Hex F LRC Ou Exclusif de tous les caract res de la trame y compris SS et ES Le nombre de caract res est fix 8 En 4 termes 00001234 En 5
16. ed to confirm entry in programming The command control of the buzzer is not possible in programming mode 3 B ILLUMINATION DURATION D 2 Enter in programming RPCECECECECECEEEE TETE Press A1 to enter in the output format menu A1 One beep is emitted Press 1 to select 26 bit wiegand output imat Press 2 to select Standard output format Press 3 to select ISO Track 2 output format One beep is emitted to confirm programming Remove the ST1 jumper Two beeps are emitted to confirm 2 exit from programming i D CODE LENGTH 1 Enter in programming if 2 Enter AO to program the illumination curation 2 One beep is emitted dti Enter the time in seconds AO 10 for 10 seconds to 99 for 99 seconds or enter 00 for a permanent illumination One beep is emitted to confirm the illumination duration 3 Remove the ST1 jumper Two beeps are emitted to confirm exit from programming Please refer to the procedure to start programming at the start of this section Enter in programming mode Press A2 to enter in the code length A2 setting menu One beep is emitted Press 4 for a 4 digit user code press 5 for a 5 digit user code or press 6 for a 6 digit user code One beep is emitted to confirm programming Remove the ST1 jumper aero Two beeps are emitted to confirm i exit f
17. exad cimal 1 bips OK 4 bips Erreur MANUEL D INSTALLATION GALEOW Digicode r tro clair Wiegand E E eS SSS aaa Eee SS aaa Termes utilis s Les codes utilisateurs doivent tre compos s de 4 5 ou 6 termes En mode d cimal seuls la touche B est interdite pour composer les codes Touche B pour valider En mode hexad cimal seuls les touches de 0 a 9 sont autoris es pour composer les codes Touche B pour valider L utilisateur doit composer son code puis appuyer sur la touche B pour valider Valeurs par d faut Tempo clairage 10s Nombre de termes 5 Sortie Wiegand 26 bits Buzzer inactif Mode d cimal Correspondance des signaux sonores 1 bip court gt Mise sous tension et bip touche 1 bip long gt Validation d une saisie en programmation 2 bips courts gt Entr e et sortie de programmation 4 bips courts gt Erreur de saisie A ENTREE EN PROGRAMMATION C PROGRAMMATION DU FORMAT DE SORTIE r i r 1 Entrez en programmation 1 Coupez l alimentation Basculez le switch sur ON R tablir l alimentation 2 Tapez A1 pour choisir J le format de sortie Ai h i Z 2 Deux bips sont mis pour confirmer l entr e en programmation La commande ext rieure du buzzer ne fonctionne pas en programmation B PROGRAMMATION DE L CLAIRAGE 1 Entrez en programmation 2 Tapez AO pour la temporisation d clairage
18. nstallation finale du produit R unissez le mat riel appropri Per euse tournevis m tre et suivez les recommandations de montage du GALEOW V rifiez la distance entre le GALEOW et la centrale ou le contr leur de porte Voir page 3 Rappels et recommandations Prenez les marques et percez les 2 trous de fixation for t 5 mm et profondeur mini mum 35 mm ainsi que l ouverture pour le passage du c ble lectrique destin au clavier Passez le c ble lectrique du GALEOW dans son ouverture et fixez le son support par le haut avec le crochet sup rieur Bloquez le GALEOW sur son support par l interm diaire de la vis TORX et de son outil sp cifique cl m le coud e Pour finaliser le montage de ce produit placez le cache vis Positionnez les 2 chevilles plastiques dans les trous Puis Fixez le fond du GALEOW sur le support de votre choix l aide des vis cruci formes t tes frais es 9 SOS SOC Raccordement aux bornier des centrales C bles LT20PB LT20AC PROMI1000 GALEOW Sorties CT V900 A LT20PBIP LT201P PROMI1000PC PROMI500 DGPROX Alimentation Alimentation 12 VDC MARRON Commande OUT5 6 ext rieur du buzzer cdvi com cdvigroup com 3 GALEOW Blanc vert Bleu Rouge Noir Gris x GALEOW ROUGE Alimentation 12 V DC OV cms commo paa I ventouse v Varistance
19. nty Voir conditions de garantie vie limit e Refer to Limited Lifetime Warra use IE A FN DLL LISE W ARRAD ry GARANTIE 4 GALEOW gt pa Uliara nei ICT i b T IZS pu P KAVK a M A be w Wiegand Digicode r tro clair de Range Integrated access control Gamme Contr le d acc s int gr Vs INSTALLATION MANUAL MANUEL D INSTALLATION C DVI Group Products Formats de sortie Wiegand Format Standard Format Iso Track 2 m R tro clair m Mati re Alliage d aluminium x Signalisation lumineuse et sonore Pose en applique x Faible encombrement m Montage avec vis Torx m Etanch it totale surmoul s Dimensions Lx Ix P 110 x 75 x 15 mm a Switch l arri re du GALEOW pour l entr e et la sortie du mode programmation s Sauvegarde m moire permanente E2PROM Nombre de termes 4 5 ou 6 a Alimentation 12 V DC Consommation 100 mA max 2 RAPPELS ET RECOMMANDATIONS Rappel de cablage Dans le cas d une connexion directe a la centrale CT V900 A CENTAUR ou une des centrales LINKNET le GALEOW doit tre plac a une distance maximale de 50 m Dans les autres situations la distance entre le GALEOW et le contr leur de porte INTBUSW doit tre de 50 m maximum et la distance entre la centrale ou platine jusqu au dernier contr leur de porte INTBUSW peut atteindre 1200 m maximum Attenti
20. on de ne pas passer vos fils a proximit de cables Courant fort ex 230 V AC Cables pr conis s Cables 2 paires 4 fils SYT1 8 10 e AWG 20 3 KIT DE MONTAGE Vis Torx a t te frais e M4x10 Varistance GALEOW cdvi com 2 cdvigroup com Cl male coud e pour vis Torx T20 NCE AUTE RESISTA AU VANDALISME OQO X DEEE amp RoHS i 164 C Certification CE 33 Test vibrations 25 C 70 C Montage Afin d optimiser la fixation du GALEOW et de pr venir les tentatives d arrachage privil giez les surfaces planes Alimentations pr conis es Une alimentation ind pendante de la centrale est n cessaire pour le GALEOW Il existe deux alimentations adapt es pour ce Digicode ARD12 ou BS60 Recommandations d installation Pour s curiser l installation n oubliez pas de placer la varistance sur le syst me de verrouillage en parall le au niveau de l alimentation placer une r sistance de 120 ohms entre A et B sur le dernier contr leur de porte du BUS RS485 Cheville pire Vis cruciforme t te frais e M4x30 MANUEL D INSTALLATION GALEOW Digicode r tro clair Wiegand 4 MONTAGE Apr s avoir v rifi que le kit de montage est complet et op r le raccordement du clavier cod GALEOW avec ou sans le contr leur de porte selon la centrale ou platine vous allez pouvoir proc der l i
21. ramming the number of digits Enter 4 5 or 6 to specify the number of digits 1 beep OK 4 beeps Error to start programming 3 Turn the switch to ON 2 beeps are emitted Programming the audible signal 0 disable the keypad beeps 1 Enable the keypad beeps 1 beep OK 4 beeps Error Turn the switch to OFF to finish programming Programming for decimal or hexadecimal mode 0 for decimal mode 1 for hexadecimal mode 1 beep OK 4 beeps Error INSTALLATION MANUAL GALEOW Wiegand illuminated keypad Default values Code Length Illumination duration 10 seconds The user code must be in 4 5 or 6 digits User code lenght 5 digits In decimal mode all the keypad keys can be 26 bit wiegand output used to program a user code except the B key Buzzer disabled In hexadecimal mode all the keypad keys can Decimal mode be used to program a user code except the A and B key Audible Signal Enter the user code and then B to validate 1 short beep gt keypad powered the code and key presses 1 long beep gt data computing in programming 2 short beeps gt Entry or Exit from programming 4 short beeps gt data computing error A ENTRY IN PROGRAMMING C OUTPUT FORMAT 1 Turn off the power Put the switch to ON Put back the power 2 Two beeps are emitt
22. rom programming 4 beeps indicate a data computing error cdvi com cdvigroup com 17 illuminated keypad E AUDIBLE SIGNAL The audible signal is always enabled in programming mode In factory default the buzzer is disabled when pressing a key To enable the buzzer 1 Enter in programming mode 2 Press A3 One beep is emitted Press 0 to disable the audible signal Press 1 to enable the audible signal One beep is emitted to confirm programming 3 Remove the ST1 jumper Two beeps are emitted to confirm exit from programming F DECIMAL OR HEXADECIMAL MODE 1 Enter in programming mode 9 26 BIT WIEGAND FORMAT 0 logic CLOCK DATAO 2ms 2 Press A4 to enter in the mode setting menu One beep is emitted Press 0 for a decimal mode press 1 for a hexadecimal mode One beep is emitted to confirm programming 3 Remove the ST1 jumper Two beeps are emitted to confirm exit from programming 4 beeps indicate a data computing error G EXTERNAL CONTROL OF THE BUZZER The buzzer can be activated from an external input The control is done with a logic signal on the input Buzzer OFF Buzzer ON Buzzer OFF OV 1 logic 2ms Please refer to the procedure to start programming at the start of this section cdvi com 18 cdvigroup com INSTALLATION MANUAL