        E-0266 Carma Industries (Div. of 1276437
         Contents
1.     The purpose of revision 1 was to include the addition  of a test interface circuit     Rev  2 Issued Date  1991 04 16    The purpose of revision 2 was to include two  additional current ratings  200 A  400 A  and one  additional voltage rating  347 V   Various hardware   firmware and mechanical modifications as well as the  30 3 wire delta and 3   4 wire wye circuits where  included     Rev  3 Issued Date  1992 07 19    The purpose of revision 3 was to include the demand  and time of use functions as well as one additional  current rating  5A      Rev  4 Issued Date  1993 10 07    The purpose of revision 4 was to include three  additional current ratings  2A  10A  125A  and five  additional voltage ratings  240V 277V 416V 480V   600V      Rev  5 Issued Date  1996 10 25  The purpose of revision 5 was to include various    hardware and mechanical changes as well as a  repackaging of the current transducers     Page 10 of de 19       R  VISIONS    Original Date d     mission   1989 07 19    R  v  1 Date d   mission   1990 04 10    La r  vision 1 visait    ajouter un circuit d interface  d essai     R  v  2 Date d   mission   1991 04 16    La r  vision 2 visait    ajouter deux valeurs de courant  nominal  200 A et 400 A  et une valeur de tension  nominale  347 V     taient   galement incluses diverses  modifications du mat  riel  du microprogramme et des  modifications m  caniques  ainsi que des  modifications des circuits triphas  s    trois fils mont  s  en triangle et des 
2.    CT TRANSFER RATIO 6 2 Vac AT 100  PRIMARY CURRENT  APPROVED PTs 120   240  277  347   416  480  600 Vac                   PT TRANSFER RATIO 5 65 VAC  Sec   AT 120   347   600 Vac  Prim    CT PT CABLES 22 AWG  Min  TWISTED PAIR  MAX 1000 FT    METER CONFIGURATIONS WYE  3PH 4W   1 EL  2 EL  3 EL   DELTA  3PH 3W   1 EL  2 EL   RESDTL  2 EL  METER MULTIPLIERS INCLUDED IN DISPLAYED ENERGY amp DEMAND  SPECIFIC PARAMETERS                      PRODUCTION DATE CODE  NETWORK ADDRESS          SERIAL NUMBER  NUMBER OF METERS  DEMAND VERIFIED          TOU VERIFIED    COMMUNICATIONS TYPE  COM BAUD RATE                E A Toll Free  1 888 298 3336  INDUSTRIES ING   Local  705 743 2401  Rev  11  Name Plate     Change Name to     Type T      R  v  11  Plaque signal  tique     Changement  de nom pour    Type T             Page 14 of de 19 Project Projet   AP AE 09 0006    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13    DIRECTIONS   1  PRESS 0 KWn       Original EMP I Display Unit  Dispositif d   affichage originale  MSE I R  v  8  Dispositif d affichage du MS   II          Rev  1  EMP I     Doors open Rev  5  EMP IT     Removable Logic Module  R  v  1  MSE I     Portes ouvertes R  v  5  MSE II     Module logique d  tachable    Page 15 of de 19 Project Projet   AP AE 09 0006          Rev 1  EMP I     Old Layout  Doors close  R  v 1  MSE I     Configuration originale  Portes  ferm  es       Rev  2  EMP I     Display Unit  New   R  v  2  MSE I     Nouveau dispositif d   affichage    Pa
3.  ceux qui sont d  crits dans la documentation  re  ue et pour lesquels des   chantillons repr  sentatifs  ont   t   fournis par le requ  rant aux fins d     valuation   conform  ment aux articles 13 et 14 du R  glement sur  l inspection de l   lectricit   et du gaz  Ce qui suit est  une br  ve description de leurs principales  caract  ristiques     DESCRIPTION SOMMAIRE      Le syst  me vis   par le pr  sent avis d approbation est  destin      mesurer l   nergie  KW h  et la puissance  appel  e  kW et kVA   tout en indiquant le temps  d utilisation  Le syst  me est con  u pour des  applications de mesure de vrac et de comptage  divisionnaire et fait appel    la m  thode des trois  wattheurem  tres pour circuits polyphas  s     Le syst  me peut mesurer jusqu    4080 circuits  monophas  s    trois fils ou circuits en r  seaux     En tant que syst  me  1l peut mesurer jusqu     4845 circuits monophas  s    trois fils ou circuits  mont  s en triangle  ou 4590 circuits en r  seau  ou  3060 circuits    quatre fils mont  s en   toile     Le syst  me se compose des six sous syst  mes  distincts illustr  s ci dessous    la figure n   1      a  Transducteur de tension  TT   Transformateur de  potentiel  TP     b  Transducteur de courant  TC     c  Module de surveillance   nerg  tique  MS       d  Affichage du MS    facultatif    e  R  seau local     f  Ordinateur central sur place  facultatif     Nota   Le r  seau local et l ordinateur central  constituent en fait le syst  me de consign
4.  in accordance with sections 13  and 14 of the Electricity and Gas Inspection  Regulations  The following is a summary of the  principal features only     SUMMARY DESCRIPTION     The metering system herein approved is intended for  metering energy  kW h   demand  KW and KVA  and  time of use metering  The system is intended for  metering both the bulk metering applications and the  sub metering applications by means of the three  wattmeter method for polyphase circuits     As a system it is capable of measuring up to 4080  three wire single phase circuits  or network circuits     As a system  it is capable of measuring up to  4845  three wire single phase or delta circuits  or 4590  network circuits  or 3060 four wire Wye circuits     The system consists of the following six functionally  distinct subsystems as depicted in Figure N   1     a  Voltage Transducers  VT   Potential Transformer   PT    b  Current Transducers  CT     c  Energy Monitoring Pods  EMP     d  EMP Display  Optional   e  Local Area Network  LAN   and   f  On Site Host Computer  Optional    Note  The LAN and HOST computers are merely the  tele metering reporting system for the Meter Manager  system  As such  no metrological functions are  performed outside of the EMP     Page 2 of de 19    APPROVAL No    N   D    APPROBATION    E 0266 Rev  13       REMARQUE   Cette approbation ne vise que les  compteurs dont la conception  la composition  la  construction et le rendement sont identiques  en tout  point    
5.  l ordinateur  central sur place     Le MS   comprend une interface d   talon Radian qui  produit une impulsion de synchronisation visant     amorcer et    interrompre l   talon Radian synchronis    avec le lecteur du MS    Il est ainsi possible de  v  rifier le syst  me     Project Projet   AP AE 09 0006    The EMP specifications are as follows     Auxiliary Supply    100  115  220  230  240 V  ac    Jumper selectable    47 to 63 Hz   95 watts    Frequency   Burden     The EMP can be a stand alone device with local  display  or operate as part of a network  The local  area network  LAN  consists of all EMP s in the  system and the on site host computer     A Host computer  PC computer  can act as a  coordinator for all EMPs     data  On any one     comport     serial  IP address  etc    the Host can  manage up to 255 EMP   s  for a total metering  capacity of 4845 three wire single phase or delta  poly phase meter nodes  2 El    circuits      or 4590  network meter nodes  2 El of 3ph 4w   or 3060  four wire poly phase meter nodes      The Host does not contribute to the metrological  functions of the system  and merely acts as a  tele metering coordinator  collects stored data from  EMPs  and network status observer  As a result  the  Host computer itself does not require verification     Communications between the host computer and the  remote billing host may be done by standard  telephone lines  LAN Internet  or by other  communications technology  typically  once per  bi
6.  s au moyen de la  m  me configuration de service     Les TC doivent   tre correctement associ  s    leur TT  de service conform  ment au sch  ma de c  blage et    la  configuration effectu  e en usine afin de mesurer avec  exactitude la consommation de puissance et d   nergie    lectriques     Project Projet   AP AE 09 0006    For network metering in a four wire wye service   three voltage transducers are connected in a three  line to neutral configuration     Fewer voltage transducers may be required for other  configurations  For example  with two voltage  transducers  19 separate 2 element circuits can be  metered by each EMP     Both three wire network and single phase circuits are  metered by the  two wattmeter  method  Data  sampled from each meter node 1s stored within  non volatile memory     The EMP consists of four distinct components     a  a multiplexer  which acts as a switch that  in  response to microprocessor commands  passes  transducer signals to the analog to digital  subsystem     b  an analog to digital converter which converts the  continuous current and voltage transducer signals  into discrete numbers  digital signals  which can  be analyzed by the microprocessor     c  a microprocessor  which controls the operation of  the entire measurement process within the EMP     d  a local area network interface which 1s the  communications channel between the EMP and the  on site host computer     The EMP incorporates an EMP Radian standard  interface which ge
7. 05 m  tres  qui s applique aux CT   s   applique aux TT     Project Projet   AP AE 09 0006    The EMP  Energy Monitoring Pod  performs the  KW h metering functions  Through use of  multiplexing and computation  the EMP can  sequentially measure the signals from up to 40  transducers  Those transducers will be a mixture of  voltage and current transducers  whereby the current  transducers are associated to a particular voltage  source in the factory configuration  In order to  accurately measure energy  the EMP requires a set of  VTs for each voltage service source that CTs are  placed on     The EMP may be configured for multiple services   whereby related VTs and CTs are associated in the  factory configuration  by means ofthe building wiring  chart  to form each meter node     The EMP is available in two versions as identified  below    EMP I Old style   EMP IT New style    The EMP IT logic module can be interfaced with the  EMP I enclosure using an    upgrade kit        The maximum number of VTs is determined by the  number of service sources entering the EMP panel   and limited to the number of associated CTs  one VT  for each CT      The EMP is more commonly configured for a  one to many relationship between VTs and CTs   whereby all meters are supplied by the same service  configuration     CTs must be correctly associated with their service  VTs as per the wiring chart and factory configuration  in order to accurately meter power and energy  consumption     Page 4 of d
8. F Le Measurement Canada  An Agency of Industry Canada Un organisme d   Industrie Canada    Mesures Canada    NOTICE OF APPROVAL    Issued by statutory authority of the Minister of  Industry for     TYPE OF DEVICE    Electricity Meter  Energy and Demand       AVIS D   APPROBATION      mis en vertu du pouvoir statutaire du ministre de  l   Industrie pour      TYPE D APPAREIL    Compteur d   lectricit       nergie et puissance appel  e    APPLICANT REQU  RANT  Carma Industries Inc   494 The Parkway  Peterborough  Ontario  K9L 7L9  MANUFACTURER FABRICANT  Carma Industries   A Division of 1276437 Ontario Inc    494 The Parkway  Peterborough  Ontario  K9L 7L9  MODEL S  MOD  LE S  RATING  CLASSEMENT  Meter Manager 120  208  240  277  347  416  480  600 V  ac c a    Meter Manager Type T 2 Element  3 Wire single phase 2   l  ments  3 fils  monophas      2 Element  3 Wire  Delta 2   l  ments  3 fils  triangle  3 Element  4 Wire Wye 3   l  ments  4 fils  en   toile  0 04 2 amperes amp  res   0 1 5 amperes amp  res   0 2 10 amperes amp  res   2 100 amperes amp  res   2 125 amperes amp  res   2 200 amperes amp  res   4 400 amperes amp  res    pd    Canada    Page 1 of de 19 Project Projet   AP AE 09 0006    NOTE  This approval applies only to meters  the  design  composition  construction and performance of  which are  in every material respect  identical to that  described in the material submitted  and that are  typified by samples submitted by the applicant for  evaluation for approval
9. ation des  donn  es de t  l  mesure du Meter Manager  En  cons  quence  aucune fonction m  trologique n est  ex  cut  e    l ext  rieur du MS       Project Projet   AP AE 09 0006    The voltage transducers are potential transformers   PT   O to rated volts RMS primary  0 to 5 65 volts  RMS secondary     The current transducers are ring type current  transformers  RMS primary currents as listed on page  1   RMS secondary current is 2 to 100 mA  converted  to volts by means of an integral resistor across the  secondary   Resistor rating is 62 ohms  0 1   1 watt   Current transducers are either tape wrapped or  encapsulated     The voltage and current transducers for each metered  circuit shall be located as close together as possible   and the current transducers shall be connected to the  EMP by a maximum 1000 feet  305 metres  of 22  AWG cable or 3 pair shielded cable  Belden 8777 or  equivalent  as detailed in the installation manual    In the case of one set of voltage transducers being  shared by two EMP panels     Dual EMP     configuration   the VT   s must be installed within 10  feet of the EMP panels  and must be connected to the  EMP   s with 3 pair shielded cable  Belden 8777 or  equivalent  as detailed in the installation manual     If the set of VTs is only connected to one EMP  the  same 1000 feet  305 metres  distance that applies to  the CTs shall apply to the VTs     Page 3 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       Les transducteur
10. circuits triphas  s    quatre fils  mont  s en   toile     R  v  3 Date d   mission   1992 07 19    La r  vision 3 visait    ajouter les fonctions de mesure  de puissance appel  e et de mesure par temps  d utilisation ainsi qu une autre valeur de courant  nominal  5 A      R  v  4 Date d   mission   1993 10 07    La r  vision 4 visait    ajouter trois valeurs de courant  nominal  2 A  10 A et 125 A  et cinq valeurs de  tension nominale  240 V  277 V  416 V  480 V et  600 V      R  v  5 Date d   mission   1996 10 25  La r  vision 5 visait    incorporer diverses  modifications de mat  riel et des modifications    m  caniques  et de d  crire le nouveau conditionnement  des transducteurs de courant     Project Projet   AP AE 09 0006    Rev  6 Issued Date  1998 06 10    The purpose of revision 6 was to include firmware  version 6 0 which allows for expanded memory so as  to increase storage data     Rev  7 Issued Date  1998 07 16    The purpose of revision 7 was to include firmware  version 5 0    Rev  8 Issued Date  2001 03 02    The purpose of revision 8 was to include a new  display unit     Rev  9 Issued Date  2005 09 22    The purpose of revision 9 was to include a change in  the mounting of the current transformer on the 5A  Interposing Transducer printed circuit board  The  current transformer has been mounted vertically   instead of horizontally  The revised PCB uses plugs in  place of terminals for interconnections     Rev  10 Issued Date  2007 02 14  The purpose of revis
11. construction and  performance of the meter type s  identified herein  have been evaluated in accordance with regulations  and specifications established under the Electricity  and Gas Inspection Act  Approval is hereby granted  accordingly pursuant to subsection 9 4  of the said  Act     The sealing  marking  installation  use and manner of  use of meters are subject to inspection in accordance  with regulations and specifications established under  the Electricity and Gas Inspection Act  The sealing  and marking requirements are set forth in  specifications established pursuant to section 18 ofthe  Electricity and Gas Inspection Regulations   Installation and use requirements are set forth in  specifications established pursuant to section 12 ofthe  Regulations  Verification of conformity is required in  addition to this approval for all metering devices  excepting instrument transformers  Inquiries  regarding inspection and verification should be  addressed to the local inspection office of Industry  Canada     ORIGINAL COPY SIGNED BY    Adnan Rashid   Senior Engineer     Electricity Measurement  Engineering and Laboratory Services Directorate    APPROVAL No    N   D    APPROBATION    E 0266 Rev  13       APPROBATION      La conception  la composition  la construction et le  rendement du des  type s  de compteurs identifi   s   ci dessus  ayant fait l   objet d   une   valuation  conform  ment au R  glement et aux normes   tablis en  vertu de la Loi sur l inspection de l   
12. d only entry to  the data via an access code     LCD     This display may be incorporated within the outer  door of the EMP cabinet  or provided as a separate  display unit     Page 8 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       Descripteur du temps d utilisation     Le descripteur du temps d utilisation indique la  p  riode d utilisation et le type de jour comme suit      Hors pointe   Off  Transition 1   Shl  Transition 2   Sh2  Pointe   On    Jour de semaine   Wkday  Fin de semaine   Wkend  Cong   f  ri     Hol    Le descripteur du temps d utilisation est suivi du signe  dollar     afin d indiquer que les donn  es  correspondent    la p  riode de facturation courante     Voici une br  ve description de chaque type  d affichage     Dispositif d affichage pilot   par PC      Ce dispositif d affichage utilise un ordinateur  personnel  PC   Il offre deux options  la premi  re est  une version   mul  e de l affichage    cristaux liquides   voir affichage    cristaux liquides   La seconde option  offre l affichage d un menu qui permet un acc  s    la  consommation en   nergie et    la demande du client     Dispositif d affichage du terminal de r  seau      Essentiellement  le dispositif d affichage du terminal  du r  seau est identique    celui d  crit ci dessus  sauf  que le clavier est remplac   par un bloc curseur  Le  consommateur peut utiliser un code d acc  s afin de  consulter les donn  es     Dispositif d affichage    cristaux liquides    Le dis
13. e 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       Le MS    module de surveillance   nerg  tique  assure  les fonctions de mesure en kW h  Par multiplexage et  calcul  le MS   peut mesurer s  quentiellement les  signaux en provenance d au plus de 40 transducteurs  r  partis en transducteurs de tension et de courant  associ  s    une source particuli  re de tension lors de la  configuration en usine  Pour mesurer l   nergie avec  exactitude  le MS   utilise un groupe de transducteurs  de tension    chaque source de tension de service     laquelle le transducteur de courant est associ       Le MS   peut   tre programm   en fonction de  multiples tensions de service  auxquelles les  transducteurs de tension et les transducteurs de  courant sont associ  s lors de la configuration en usine   conform  ment au sch  ma de c  blage du b  timent   pour former des noeuds de compteurs     Le MS   est disponible en deux versions  Voir ci   dessous    MS   I Ancien style   MS   II Nouveau style    Le module logique de MS   II peut   tre interfac   avec  le bo  tier de MSE I en utilisant un    un ensemble  pr  fabriqu   d   am  lioration        Le nombre maximal de TT est   tabli en fonction du  nombre de sources de tension de service entrant dans  le tableau du MS   et est limit   au nombre de TC  associ  s  un TT pour chaque TC      Le MS   est habituellement configur   pour un rapport  entre les TT et les TC de un    plusieurs  par lequel  tous les compteurs sont aliment 
14. e v  rification     Les communications entre l ordinateur central sur  place et l ordinateur de facturation    distance se font  par ligne t  l  phonique normale  LAN Internet ou par  d autres techniques de communication  habituellement  une fois par p  riode de facturation   Au cours de ces  communications  l ordinateur central transmet toutes  les donn  es de consommation de chaque noeud du  syst  me  ainsi que l   ventuel journal des erreurs de  chaque MS       Project Projet   AP AE 09 0006    The on site host computer enables the operator to  query local area network status  consumption data   specific information regarding status of any  consumption node and any errors which have  occurred in the system     The metering system permits factory and user  programmable features for demand measurements of  KW and kVA  The system may be programmed for  sliding window or block interval demand as well as  for the demand interval     The system  when metering both the bulk metering  applications and the sub metering applications can  measure co incidental peak demand by means of  synchronizing signal which is broadcasted across the  local area network to each EMP     The system employs one or more of the following  displays       PC based display  two available options        Network terminal display     Liquid crystal display  LCD   and    Multiple display     At least one of these displays shall be installed in a  location accessible to the consumers being metered   The consum
15. eris thereby able to interrogate the on site  host computer for specific data relating to his her  individual consumption and  1f time of use metering  is being used  the date  time and time of use  TOU   descriptor     A consumer enters his her personal identification  number and the display shows the date  time  TOU  descriptor  1f applicable  and      6  kW h      Page 7 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       L ordinateur central sur place permet    l utilisateur de  consulter l   tat du r  seau  les donn  es de  consommation  des donn  es pr  cises relatives    l   tat  de tout node de consommation et les erreurs qui se  sont produites dans le syst  me     Le syst  me de mesure permet la programmation     l usine et par l utilisateur des caract  ristiques  m  trologiques permettant la mesure de la puissance  appel  e en kW et en kVA  Le syst  me peut   tre  programm   pour mesurer par fen  tre mobile ou par  intervalle d int  gration     Lorsque le syst  me est utilis   avec des applications de  mesure de vrac et de comptage divisionnaire  1l peut  mesurer les puissances appel  es de pointe  coincidentes au moyen d un signal de synchronisation  transmis    chaque MS   dans l ensemble du r  seau  local     Le syst  me utilise un ou plusieurs des dispositifs  d affichage suivants        Dispositif d affichage pilot   par PC  deux options  possibles       Dispositif d affichage du terminal du r  seau      Dispositif d affichage    cristaux liq
16. ge 16 of de 19       APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       n DS E A 6 Le  amp  Le ee F3 7e  M NN   Mn iZl en Es    ER ED en  Pre 2e             Rev  5  EMP II     New Layout  Doors open  R  v  5  MSE IT     Nouvelle configuration  portes  ouvertes       Rev 12  fully welded hinge  R  v 12  charni  re soud  e    Project Projet   AP AE 09 0006    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       CELLES       Rev  10  Voltage  Potential  Transformers  R  v  10  Transformateurs de tension       Rev  13  The EMP II logic module interfaced with the EMP I enclosure   R  v  13  Le module logique de MSE IT avec interface du bo  tier de MSE I     Page 17 of de 19 Project Projet   AP AE 09 0006    APPROVAL No    N   D   APPROBATION  E 0266 Rev  13       Rev  3  Interposing Transducer PCB  Old  layout  Rev  A    R  v  3  Carte de circuits imprim  s    Interposing  Transducer     ancienne configuration  Rev  A        Rev  13  Voltage transformer sealing  R  v  13  Sc  llage du transformateur de tension       Rev  9  Interposing Transducer PCB        Rev  9  Interposing Transducer PCB  New Layout New Layout  Rev  C  Bottom View   Rev  C  Top View R  v  9  Carte de circuits imprim  s  R  v  9  Carte de circuits imprim  s   Interposing   Interposing Transducer    nouvelle  Transducer    nouvelle configuration  Rev  C  Vue configuration  Rev  C  Vue du   du dessus dessous    Page 18 of de 19 Project Projet   AP AE 09 0006    APPROVAL     The design  composition  
17. ion 10 was to approve the use of  one set of Potential transformers by two co located  EMP panels  Also to restrict the Meter Manager    s  use in certain applications   Rev  11 Issued Date  2007 05 22    The purpose of revision 11 was to include a new  nameplate     Page 11 of de 19    APPROVAL No    N   D    APPROBATION    E 0266 Rev  13       R  v  6 Date d   mission   1998 06 10    La r  vision 6 visait    inclure la version 6 0 du  microprogramme de m  me qu une m  moire  d expansion pour augmenter la capacit   de stockage  des donn  es     R  v  7 Date d   mission   1998 07 16    La r  vision 7 visait    inclure la version 5 0 du  microprogramme     R  v  8 Date d   mission   2001 03 02    La r  vision 8 visait    inclure un nouveau dispositif  d affichage     R  v  9 Date d     mission   2005 09 22    La r  vision 9 visait    inclure une modification du  montage du transformateur de courant 5A sur la carte  de circuits imprim  s    Interposing Transducer     Les  transformateurs ont   t   mont  s verticalement plut  t  que horizontalement  La nouvelle carte de circuits  imprim  s emploie des fiches pour les interconnexions  au lieu de bornes   R  v  10 Date d     mission   2007 02 14  La r  vision 10 visait    approuver l utilisation d un  groupe de transformateurs de tension pour deux  panneaux MSE colocalis  s  Et   galement    restreindre  sont utilisation dans certaine condition    R  v  11 Date d     mission   2007 05 22    La r  vision 11 visait    inclure une no
18. lectricit   et du  gaz  la pr  sente approbation est accord  e en  application du paragraphe 9 4  de ladite Loi     Le scellage  l   installation  le marquage et l   utilisation  des compteurs sont soumis    inspection  conform  ment au R  glement et aux normes   tablis en  vertu de la Loi sur l inspection de l   lectricit   et du  gaz  Les exigences de scellage et de marquage sont  d  finies dans les normes   tablies en vertu de l   article  18 du R  glement sur l inspection de l   lectricit   et du  gaz  Les exigences d   installation et d utilisation sont  d  finies dans les normes   tablies en vertu de l   article  12 du R  glement  Sauf dans les cas des  transformateurs de mesure  une v  rification de  conformit   est requise en plus de la pr  sente  approbation  Toute demande de renseignements  relative    l inspection et    la v  rification de  conformit   doit   tre adress  e au bureau local  d Industrie Canada     COPIE AUTHENTIQUE SIGN  E PAR   Adnan Rashid   Ing  nieur principal     Mesure de l     lectricit    Direction de l   ing  nierie et des services de  laboratoire    Date   2010 03 04    Web Site Address   Adresse du site Internet  http   mc ic gc ca    Page 19 of de 19    Project Projet   AP AE 09 0006    
19. lling period   During this communication  the  on site host computer transmits all consumption data  for each node in the system as well as the error log  that may exist for each EMP     Page 6 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       Le MS   pr  sente les caract  ristiques suivantes      Alimentation auxiliaire    100  115  220  230 et 240 V  c a     s  lection par cavalier    Fr  quence   47    63 Hz   Consommation   95 watts    Le MS   peut   tre un appareil autonome avec  affichage local ou faire partie d un r  seau  Le r  seau  local  LAN  comprend tous les MS   du syst  me et  l ordinateur central sur place     Un ordinateur central  ordinateur personnel  peut  servir pour coordonner l ensemble des donn  es des  MS    Sur l un ou l autre des ports de communication   s  rie  adresse IP  etc    l ordinateur central peut  prendre en charge jusqu    255 MS    pour une capacit    de mesure totale de 4845 nodes de compteurs  monophas  s    trois fils ou polyphas  s mont  s en  triangle  circuits    2   l  ments   ou 4590 nodes de  compteurs mont  s en r  seau  circuits triphas  s     2   l  ments 4 fils   ou 3060 nodes de compteurs  polyphas  s    4 fils      L ordinateur central ne contribue pas aux fonctions  m  trologiques du syst  me et doit simplement agir  comme coordonnateur de la t  l  mesure  recueille les  donn  es provenant des MS    et d observateur de l   tat  du r  seau  En cons  quence  l ordinateur central  lui m  me n exige pas d
20. n      S N  YXX    EMPXX      VER 3 5    MMXXXX      In house serial number   Num  ro de s  rie interne   Energy monitoring pod network address   Adresse du r  seau du module de surveillance    nerg  tique    YXX EMPXX marked also in serial number space on door nameplate   YXX EMPXX inscrit    galement dans l espace r  serv   au num  ro de s  rie sur la plaque signal  tique de la porte     Firmware version   Version de la microprogrammation  Meter Manager variation number  in house control number used to identify transducer scaling  factors burnt into PROM   Autre num  ro du syst  me Meter Manager  num  ro de contr  le    interne servant    identifier les facteurs d   chelle des transducteurs grav  s en m  moire morte  programmable  PROM        Page 13 of de 19 Project Projet   AP AE 09 0006    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13    METER MANAGER    ENERGY MONITORING POD    HAMAAQUENRES    PETERBOROUGH ONT  K9J 7L9    TRANSFORMER TYPE LOSS COMPENSATED       Original Name Plates  EMP I only   Plaque signal  tique originale  MSE I seulement     EN m 2N ONE  NN mamie  T VI  EX IAA NINNI A NE  EX    ENERGY MONITORING POD    TYPE T EMP    LR85853       AUXILIARY SUPPLY 120 Vac 50 60 Hz 24VA  MC APPROVAL   E 0266  INDUSTRY CANADA APPROVED        FREQUENCY 50   60 Hz  TEMPERATURE  40  C TO 55  C          METROLOGY INPUTS 6 2 Vac  Typical        10Vdc  Max   CONFIGURATION DETAILS   SEE WIRING CHART FOR PRGD VOLTS AMPS  APPROVED CTs 2A  5A  10A  100A  125A  200A  400A
21. n clavier de  dix touches et un afficheur    deux lignes de vingt  caract  res chacune     Le dispositif d affichage    cristaux liquides du     nouveau mod  le    de MS   comporte un clavier     trois touches et un afficheur    deux lignes de quarante  caract  res chacune     Affichage multiple      Ces dispositifs d affichage sont constitu  s de multiples  afficheurs connect  s en r  seau  r  seau local  de  communication  L affichage multiple permet aux  consommateurs d avoir un acc  s   largi au syst  me de  mesure     Autres caract  ristiques  sauf indication contraire     Temp  rature de fonctionnement    40   C     53   C  Alimentation auxiliaire    115 V c a   eff   10   de 47    63 Hz  D  bit en bauds   1200  9600  Versions du microprogramme    3 0  3 5  4 0  5 0  6 0 et 7 1  pour plus de  d  tail  consulter la figure 2  Identification du  syst  me    Meter Manager         Le couvercle int  rieur de bo  tier du MS   doit   tre  scell   et le couvercle ext  rieur peut   tre scell   par le  fournisseur     La charni  re du couvercle ext  rieur du bo  tier du MS     IT est soud  e     Pour obtenir de plus amples renseignements sur la  conception  la construction  les principes de  fonctionnement  l   talonnage  l installation et  l utilisation de l appareil  consulter les manuels ou la  documentation du fabricant  ou s adresser au fabricant  ou    ses agents     Project Projet   AP AE 09 0006    REVISIONS  Original Issued Date  1989 07 19  Rev  1 Issued Date  1990 04 10
22. nerates a synchronizing pulse to  start and stop the Radian standard synchronized to the  EMP scan  This permits verification of the system     Page 5 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       Pour la mesure de circuits en r  seau    quatre fils  mont  s en   toile  chacun des trois TT est raccord    suivant l une des trois configurations de tension  phase neutre ou de tension ligne    ligne     Un nombre moins   lev   de TT peut   tre requis pour  d autres configurations  Par exemple  dans le cas de  deux TT  19 circuits distincts    deux   l  ments peuvent    tre mesur  s par chaque MS       Les r  seaux    trois fils et les circuits monophas  s sont  mesur  s par la m  thode des   deux wattm  tres    Les  donn  es recueillies de chaque node de compteurs sont  stock  es dans une m  moire r  manente     Le MS   est constitu   de quatre   l  ments distincts      a  un multiplexeur qui joue le r  le de commutateur et  qui  en r  action aux commandes du  microprocesseur  transmet les signaux des  transducteurs vers le sous syst  me  analogique num  rique     b  un convertisseur analogique num  rique qui  convertit les signaux continus des transducteurs de  courant et de tension en nombres discrets  signaux  num  riques  que le microprocesseur analyse     c  un microprocesseur qui commande le d  roulement  de tout le processus de mesure    l int  rieur du  MSE     d  une interface r  seau local qui constitue le moyen  de communication entre le MSE et
23. ois phase  3 fils     R  v  13    La r  vision 13 vise    approuver l   utilisation du  module logique de MS   II interfac   avec le bo  tier de  MS   I en utilisant un    un ensemble pr  fabriqu    d am  lioration        La image de scellage du transformateur de tension est  chang  e pour r  v  ler le mod  le de production       VALU   PAR    Bissagar Fred  Originale  R  v  1    R  v  06  M  trologiste l  gal principal    Maranda Michel  R  v  07  Coordonateur technique int  rimaire    Gagn   Alain  R  v  08  M  trologiste l  gal    Rozeboom Michael  R  v  09  R  v  10  M  trologiste l  gal    Brown Michael  R  v  11  M  trologiste l  gal junior    Abderrahmane Cherradi  R  v  12  M  trologiste l  gal junior    Greg Neff  R  v  13  M  trologiste l  gal junior    Project Projet   AP AE 09 0006    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13    FIGURE N   1    METER MANAGER    C Distribution    Panel    Module de surveillance de l     nergie  Transducteurs de courant   Tableau de distribution  Transducteurs de tension   R  seau local   T  l  affichage   T  l  facturation   Ordinateur central sur place    LI  um E  nt    za  za      g   Remote   Billing  HIT AL    On w n    pm    O    i  SYSTEM A ARCHITECTURE    Figure n  2  Meter Manager System Identification  Identification du syst  me Meter Manager    Legend L  gende   S N  YXX   EMPXX _   ar  VER  3 5 MMXXXX EPROM LABEL Y   Alphabetic alphab  tique      tiquette EPROM X   Numberic num  rique    Definition D  finitio
24. positif peut   tre install   sur la porte ext  rieure    du bo  tier du MS   ou fourni comme dispositif  d affichage distinct     Project Projet   AP AE 09 0006    For the    Old style    EMP  the LCD unit consists of a  ten key keypad and a display consisting of two lines  of twenty characters each     For the    New Style    EMP  the LCD unit consists of  a three key keypad and a display consisting of two  lines of forty characters each     Multiple display     These displays consist of a number of remote displays  linked via a communications local area network   Multiple displays allow for expanded access by  consumers at the site being metered     Additional Specifications  except as otherwise stated      Operating Temperature   40  C to  53  C  Auxiliary Supply    115 V  ac  RMS 410  47 to 63 Hz  Baud Rate  1200  9600    Firmware Versions   3 0  3 5  4 0  5 0  6 0 and 7 1  for explanation  see  Meter Manager System Identification    Figure 2     The inner cover of the EMP enclosure shall be sealed  and the outer cover can be sealed by the contractor     The outer cover hinge of the EMP IT1s fully welded     For further information regarding design   construction  theory of operation  calibration   installation and use  consult manufacturer s manuals   etc  or consult the manufacturer or his agent s      Page 9 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       Le dispositif d affichage    cristaux liquides de  l    ancien mod  le    de MS   comporte u
25. s de tension sont des transformateurs  de tension dont la tension efficace au primaire va de  0 volt    la capacit   nominale en volts et la tension  efficace au secondaire  de 0    5 65 volts     Les transducteurs de courant sont des transformateurs  de courant de type annulaire  les courants efficaces au  primaire sont   num  r  s    la page 1   Le courant  efficace au secondaire va de 2    100 mA  convertis en  volts au moyen d une r  sistance aux bornes du  secondaire   La capacit   nominale de la r  sistance est  de 62 ohms  0 1    1 watt  Les transducteurs de  courant sont soit enrubann  s soit encapsul  s     Les transducteurs de tension et de courant destin  s     chaque circuit mesur   doivent   tre install  s le plus  pr  s possible les uns des autres et les transducteurs de  courant doivent   tre reli  s au MS   par un c  ble de  calibre 22 AWG de 1000 pieds  305 m  tres  au plus  ou trois paires de c  bles arm  s  Belden 8777 ou  l   quivalent  comme indiqu   dans le manuel  d installation     Dans le cas d un groupe de transducteurs de tension  connect  s    deux panneaux MS    configuration    double MS       les TT doivent   tre install  s    moins  de 10 pieds des panneaux MS   et   tre connect  s    ces  derniers au moyen de trois paires de c  bles arm  s   Belden 8777 ou l   quivalent  comme indiqu   dans le  manuel d installation     Dans le cas d un groupe de transducteurs de tension  connect  s    un seul panneau  la r  gle de la distance de  1000pieds  3
26. uides      Dispositif d affichage multiple     Au moins un de ces dispositifs doit   tre install      un  endroit accessible par le consommateur  Ce dernier  peut ainsi interroger l ordinateur central pour obtenir  des donn  es relatives    sa propre consommation et  s1  la mesure est effectu  e en fonction du temps  d utilisation  la date  l heure et le descripteur du temps  d utilisation     Le consommateur entre son num  ro d identification et  le dispositif d affichage indique la date  l heure  le  descripteur du temps d utilisation  s il y a lieu  et  CET EE kW h        Project Projet   AP AE 09 0006    Time Of Use Descriptor     The TOU Descriptor indicates the present TOU period  and type of day as follows     Off peak   Off  Shoulder 1   Shl  Shoulder 2   Sh2  On peak   On  Weekday   Wkday  Weekend   Wkend  Holiday   Hol    The TOU descriptor is followed by a dollar sign     to  indicate the information as being in the current billing  period     The following are summary descriptions of the  displays     PC based display     This display utilizes a personal computer  PC   The  display offers two options  the first being an emulated  version of the liquid crystal display  see LCD   The  second option provides a menu display which allows  access to the consumer s energy consumption and  demand     Network terminal display     Essentially  the network terminal display is the same  as above  except that the keyboard is replaced by a  cursor pad  The consumer may gain rea
27. uvelle plaque  signal  tique     Project Projet   AP AE 09 0006    Rev  12 Issued Date  2009 01 21    The purpose of revision 12 was to include a new  firmware which allows for the removal of the  restrictions of revision 10 on delta metering 3 phases   3 wires where loading could exceed 0 5 power factor  and reverse accumulation  Revision 12 also included  one additional voltage rating 208 V for 3 phase 3 wire  metering     Rev  13    The purpose of revision 13 is to approve the usage of  the EMP II logic module interfaced with the EMP I  enclosure using an    upgrade kit        The voltage transformer sealing image is changed to  reflect the production model     EVALUATED BY    Bissagar Fred  Original and Rev  1 to Rev  06  Senior Legal Metrologist    Maranda Michel  Rev  07  Acting Technical Coordinator    Gagn   Alain  Rev  08  Legal Metrologist    Rozeboom Michael  Rev  09  Rev  10  Legal Metrologist    Brown Michael  Rev  11  Junior Legal Metrologist    Abderrahmane Cherradi  Rev  12  Junior Legal Metrologist    Greg Neff  Rev  13  Junior Legal Metrologist    Page 12 of de 19    APPROVAL No    N   D   APPROBATION    E 0266 Rev  13       R  v  12 Date d     mission   2009 01 21    La r  vision 12 visait    inclure un nouveau progiciel  afin de retirer les restrictions  dans la r  vision 10  sur  la configuration triangle 3 phases  3 fils    un facteur  de puissance exc  dant 0 5 et en cas de flux inverse  d   nergie    gale elle visait    inclure le mesurage     208V  tr
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User`s manual - AT&T FactoryOutletStore.com  Manual - Pioneer    MANUEL D`UTILISATEUR  DETERBAC - Quimicas Morales  Mise en page 1 - Sausset-les-pins    Manual de Instalación y Uso    SD cover.indd - Instrumentors Supply, Inc.    Copyright © All rights reserved. 
   Failed to retrieve file