1. 1 N Nordpeis AS Gjellebekkstubben 9 11 N 3420 LIERSKOGEN Norway www nordpeis no
2. Acrylic glue This is used for gluing the elements towards wall gluing the elements together and for filling joints Painting The surround can be painted 24hrs after that it has been assembled Any surface that has been filled needs to be smoothened with fine sand paper Use latex or acrylic based paint emulsion paint Marble granite Clean the plates with mild soapy water and remove any remaining glue Fine Fissures Settlement cracks can appear during the first year of new built houses For this reason very thin fissures could appear in the joints between the elements the firewall and the chimney This is entirely normal and no reason for concern These small fissures can be removed by renewing the joint Scrape out the joint with a joint scraper and then vacuum clean to remove all the dirt Inject acrylic into the joint and even out by using the fingertip with some soapy water After about 24 hours the joint can be repainted Smaller damages These are successfully repaired with the provided powder glue If the damage is deep we recommend filling twice in order to avoid sinking Fill smaller cracks and uneven surfaces with a float or a brush Smoothen the surface with a damp sponge or sand paper For your own safety comply with the assembly instructions All safety distances are minimum distances Installation of the insert must comply with the rules and regulations of the country where installed Nordpeis AS is not res
3. Marmo granito Pulire le superfici con acqua e sapone e rimuovere qualsiasi residuo di colla Screpolature e spaccature E normale che una casa di nuova costruzione possa presentare nei primi anni di vita dei cedimenti localizzati che possono provocare screpolature e piccole crepe nelle strutture ci che pu avvenire anche nella struttura del caminetto provocando delle screpolature nel rivestimento che rientrano comunque nella normalit Se appaiono delle crepe opportuno allargarle leggermente ad esempio con un cacciavite aspirare i residui di polvere mediante aspirapolvere e riempire poi la fessura iniettando del materiale sigillante a base acrilica distendendolo con un dito bagnato con acqua e sapone Una volta essiccato sar possibile procedere alla pittura dopo circa 24 ore Piccoli Danni Questi possono essere facilmente riparati usando la colla in polvere fornita assieme al camino Nel caso in cui il danno sia molto profondo si consiglia di stuccare a pi riprese per evitare i ritiri dello stucco derivanti dall essiccamento Piccoli fori o irregolarit si possono stuccare con una spatola od un piccolo frattazzo e dopo una breve attesa si possono lisciare con una spugna umida o della carta abrasiva Per la vostra sicurezza rispettare le istruzioni per il montaggio Tutte le distanze di sicurezza sono distanze minime Il montaggio dell inserto deve rispettare le normative ed i regolamenti del paese in cui viene ins
4. nt tehd n onton jalkaosan kautta V ltt ksesi kondensioveden syntymisen ontto jalkaosa voidaan t ytt eristeell tulenkest v kivivilla 2 11 Informations generales Nos habillages sont tous faits de materiaux non inflammables Tous nos foyers po les sont valu s selon les derni res exigences europ ennes ainsi qu a la norme norvegien SINTEF qui inclut des essais de particules Plusieurs pays europ ens ont cependant des r gles individuelles d installation des foyers des po les et des chemin es Vous comme un client tes totalement responsables du respect de ces regles locales concernant l installation dans votre r gion pays Nordpeis Northstar n est pas responsable quant l installation Vous devez v rifier la conformite des reglements locaux concernant la distance du foyer aux mat riels inflammables des mat riels exigences d isolation entre les habillages du cheminee et le mur d adossement e les dimensions des plagues de sol devant la chemin e po le si exige connexion avec le conduit de fum e et la sortie des fumees entre le foyer et la cheminee des exigences d isolation si le conduit de fumee au travers d un mur inflammable Reglage Monter pr alablement sec l habillage et le foyer pour trouver les dimensions exactes avant de perforer la chemin e pour le raccordement de conduit de fum e Utilisez un niveau a bulle pour s assurer que l hab
5. Pieni Kaareva FIG19 gt Ennen asennusta huokoiset pinnat k sittelem t n eca Scanpor Siporex jne pit rapata liimapest tai saumata akryyliliiman kuivumisen v ltt miseksi KUVA 5 KUVA 9 KUVA 19 Pohjalevy 1 asennetaan vaakasuoraan ja asetetaan 90 kulmaan savupiipun palomuurin suhteen S d tarvittaessa kiiloilla tai kiinnityslaastilla KUVA 6 KUVA 12 Est ksesi betoniosien murtumisen levit liimaa ter ksisten tukipalkkien p lle koko palkkien pituudelta V lej tai kuplia ei saa j d KUVA 15 KUVA 22 Korvaa tulipes n jalat betonikuoren mukana toimitetuilla jaloilla Liitett ess putki yl liit nt n savuluukku pit siirt taempaan hormiliit nt n KUVA 16 KUVA 23 Muista j tt tulipes n ja kuoren v lille rako koska tulipes laajenee l mmetess n Lue my s savupiipun liitt mist k sittelev kappale KUVA 18 KUVA 25 KUVA 29 Irrota varovasti kuoren peitelevy jos savupiippuliit nt on sivulla Paloilmaliit nt lis varuste Katso my s erillinen asennusohje Paloilmaliit nt KUVA 32 Kun asennetaan paloilmaliit nt sein n l pi tee my s reik takan kuoreen ett saat paloilmaliit nt putken asennettua KUVA 33 Kun asennetaan paloilmaliit nt lattian l pi Tokyo Korkea ja Tokyo Matala malleihin paloilmaputkiasennetaan takan jalkaosaan Tokyo Kapea mallissa on jo asennettuva paloilmakanava Yksi jalkaosa on ontto Paloilmaliit
6. d angle pour connecter le conduit lat ralement FIG 33 Quand l apport d air frais passe par le plancher Le tuyau est conduit dans l int rieur du socle de Tokyo Haut Bas Pour Tokyo Slim il a d j un trou dans une des jambes par lequel le tuyau est conduit Afin de pr venir la condensation la jambe peut tre remplie d un isolant 13 Informazioni generali I nostri rivestimenti sono tutti realizzati con materiali non combustibili Tutti i nostri inserti stufe sono collaudati secondo gli ultimi requisiti europei e soddisfano anche la normativa norvegese SINTEF che comprende test di particelle Comunque molti paesi europei hanno normative autonome per Pinstallazione d inserti stufe e camini Lei come cliente totalmente responsabile nell adempimento di queste regole locali per l installazione nella sua regione paese Nordpeis Northstar non responsabile per quanto riguarda la corretta installazione Verificare le normative locali per quanto riguarda distanza dal focolare a materiali combustibili e materiali isolanti distanza tra il rivestimento del camino e la parete posteriore dimensioni della piastra pavimento davanti al camino stufa se necessaria requisiti di isolamento se la canna fumaria passa attraverso un muro infiammabile come una parete di legno Posizionamento Si consiglia di montare a secco i particolari del camino rivestimento e inserto senza colla per trovare la po
7. f rdjupning mellan elementen FIG Z M lning M lning kan utf ras s snart limfogarna r torra Anv nd endast fuktgenomsl pplig f rg akryl avsedd f r murverk Om struktur nskas kan lite cementlim blandas i f rgen Behandling av marmor Reng r plattorna med svag tv ll sning och avl gsna alla eventuella limrester Eventuella repor i m rk marmor kan fyllas med blyerts Ett stencenter kan vara behj lpligt med olika produkter f r ytbehandling av sten Sprickor Normalt f r nya hus betydande s ttningar de f rsta ren Dessutom kryper alla betongelement i avtagande grad de f rsta 15 m naderna Det g r att fogarna mellan element brandmur och skorsten f r elementspisen kan spricka G r s h r Anv nd spisen under n gra m nader Om sprickor uppst r skrapar du ur dem med en skruvmeisel f r att ge plats f r mer fogmassa och dammsuger f r att avl gsna all smuts Applicera akrylfogmassa och j mna till massan med en fingertopp doppad i tv ll sning Efter n gra dygn kan fogen m las Over Sm skador Efter l ng transport kan spisen ha f tt sm rre skador De flesta skador kan dock enkelt repareras med medf ljande cementlim och spackel Om skadan r djup rekommenderas att du spacklar i tv omg ngar f r att undvika sjunkningar Mindre skador och oj mnheter spacklar du med vanligt sandspackel Efter en stund kan du j mna med en fuktig svamp F r din egen s kerhet f lj monteringsanvisninga
8. ykinnf ringen i pipen Innsatsen ekspanderer under fyring og m ikke hvile p ilegget omrammingen men ha en avstand p minimum 2 3 mm Omrammingen m heller ikke hvile p innsatsen i overkant eller i sidene Ved topptilslutning til st lpipe henviser vi til respektive fabrikats monteringsanvisning Krav til gulvplate ved brennbart gulv Gulvplaten foran peisen stein st l eller lignende skal minimum v re 300 mm dyp Avstanden fra bakkant av brennkammeret og frem til ytterkant av gulvplaten skal v re minimum 800 mm Er avstanden fra gulv til underkant av innsatsen h yere enn 470 mm skal det overskytende legges til p dybden av gulvplaten Eksempel Hvis avstanden fra gulv til underkant av innsats er 850 mm skal dybden p gulvplaten v re minst 680 mm Regnestykket blir 850 mm 470 mm 300 mm 680 mm Hvis innsatsen har panoramad r og kun skal fyres lukket kreves 300 mm gulvplate uansett h yde og dybde p ildstedet Bruk av gnistfanger anses ikke som lukket fyring NB Se egen monteringsanvisning for innsatsen Se egen monteringsanvisning for innsatsen Lim Elementene skal limes med medf lgende lim S rg for at alle limflater er frie for stov For bedre heft kan overflatene vaskes La overflaten torke for lim strykes p N r peisen er ferdig montert etterfyll skjatene mellom elementene med akryl og jevn fugen med en s pev t svamp eller finger slik at det blir en tydelig fordypning mellom elementene F
9. 2 Byt ut insatsens ben mot de ben som r emballerade tillsammans med betongomramningen Vid toppanslutning till r r ska r kluckan flyttas till det bakre r kuttaget FIG 16 FIG 23 Kom ih g att l mna en spalt mellan insatsen och omramningen eftersom insatsen expanderar under eldning L s ven avsnittet om anslutning till skorsten FIG 18 FIG 25 FIG 29 Vid skorstensmontering i sidled skall f rsvagningen i betongen f rsiktigt bankas ut Tillf rsel av uteluft tillbeh r Se ocks egen monteringsanvisning Fig 32 Vid montering av luftintag genom v ggen g rs ett h l i betongomramingen med en vinkelslip s att r ret kan f ras in fr n sidan Fig 33 Vid montering av luftintag genom golvet f rs r ret upp l ngs insidan av b nken p Tokyo H g L g P Tokyo Smal f rs r ret in i extisterande h l i bottenplattan ocks definierad p m ttritningen och vidare inv ndigt i ett av benen Montera f rst det flexibla r ret och tr d refter p betongdelarna Benet kan fyllas med isolering f r att f rhindra kondens Yleist elementtitakoista Paino Talon omistajan on varmistettava ett lattia kest takan kokonaispainon aiheuttaman kuormituksen Harkitse lattian vahvistamista erityisesti uusissa taloissa ja kun takan alla ei ole lis tukia Kelluvan puulattian p lle asennettaessa takka pit upottaa jotta lattia ei repeydy Palomuuri Kun tulisija asennetaan tulenarkaa sein vas
10. IG 2 Maling Maling kan utfores s snart limskjotene er torre Bruk kun pustende maling akryl ment for murverk Dersom det onskes struktur kan det blandes litt fliselim i malingen Behandling av marmor Rengjor platene med svakt s pevann og fjern evt alle rester av limsgl Riper i mark marmor evt farges med blyantbly Et steinsenter kan vaere behjelpelig med ulike produkter for overflatebehandling av stein Sprekker Normalt vil nye hus f betydelige setninger de forste arene i tillegg krymper alle betongelementer i avtagende grad i inntil 15 mnd Resultatet er at elementpeisen kan sprekke i skjotene mellom elementene brannmur og pipe Slik gjor du Bruk peisen i noen m neder Dersom den sprekker riss opp sprekken med f eks en skrutrekker for gi bedre plass til fugemasse og st vsug for fjerne alt st v Spr yt inn akryl fugemasse og jevn massen til med en s pev t svamp eller fingertupp Etter et par d gn kan fugen overmales Sm skader Grunnet transport og h ndtering kan det oppst sm skader p peisen Dette kan repareres med medf lgende fliselim For perfekt resultat kan du sparkle og slipe med egnet sparkelmasse utenp fliselimet Mindre s r og ujevnheter sparkles Dersom s ret er dypt anbefales det sparkle i flere omganger for unng synk Jevn til med f eks en fuktig svamp eller et flisebrett For egen sikkerhet f lg monteringsanvisningen Alle sikkerhetsavstander er minimumsa
11. Nordpeis Monteringsanvisning 2 Installation manual 4 Monteringsanvisning 6 SE Monteringsanvisning 8 FD Asennusohje 10 Manuel d installation 12 IT gt Manuale d installazione 14 Montageanleitung 16 Tokyo Art no 00 000 02 000 29 09 2010 Generelt om element peiser Vekt Huseier m forsikre seg om at gulvet t ler belastningen i henhold til totalvekten p peisen Vurder eventuelt forsterkning av gulvet spesielt i nye hus og dersom omr det under peisen ikke har ekstra lettvegger som understotter Ved montering p flytende tregulv peisen felles ned for unng at gulvet l ses og sprekker Brannmur Ved montering av ildsted inntil brennbar vegg m det anvendes brannmur Vi anbefaler bruk av Nordmur brannmurelementer som gir en meget god beskyttelse av veggen og har en byggetykkelse p kun 65 mm inklusive 15 mm luftespalte Brannmur kan ogs bygges av annet steinmateriale som gassbetongblokker eller teglsten Minimumstykkelsen m da v re 100 mm gassbetongblokker eller 108 mm teglsten Brannmuren m alltid vaere s hoy at avstanden fra r ykr r r ykklokke til brennbart materiale blir minimum 300 mm Frittst ende peiser kan monteres uten brannmur Overhold alle sikkerhetsavstander til brennbare materialer Tilkobling til pipe F lg pipeprodusentenes spesifikasjoner for tilkobling til pipe T rrstable omrammingen og innsatsen for n yaktig h yde og posisjon til r
12. a Tokyo Plat H Courbee Tokyo Slim Cappa Curvata Tokyo S Formhaube mm En s 90 4 2140 1570 750 850 sz 24 4 gt gt lt gt 1000 m X mi 8 NE N lt FIGA K i 1 O 47 X 1 5 N N N U oz N i 5 U NT N N N N N N N N N N pr NI Tokyo 26 Tokyo Hoy Tokyo High Tokyo Hoj Tokyo H g Tokyo Korkea Tokyo H 27 98 98 28 Tokyo Smal Tokyo Slim Tokyo Pieni Tokyo Plat 80 mm 745 mm 30 Tokyo topp rett Tokyo top straight Tokyo tasainen yl osa Tokyo cappa rettangolare Tokyo hotte rectangulaire Tokyo gerade kaminhaube 31 Tokyo topp buet Tokyo top curved Tokyo topp b jd Tokyo kaareva ylaosa Tokyo cappa curvata Tokyo hotte courb e Tokyo Formhaube 32 Friskluftstilforsel Fresh air supply Tillf rsel av uteluft Paloilmaliit nt Presa d aria esterna L apport d air Zuluftkit
13. aut 926 kg Tokyo Bas Hotte Courb e 440 kg Tokyo Haut Hotte Courb e 533 kg Tokyo Plat 423 kg Tokyo Plat Hotte Courb e 430 kg Distances de securite FIG 1 Prenez soin de respecter les distances de securite indiquees S il vous plait noter que ces distances de s curit peuvent varier d un pays a l autre A La distance minimale respecter entre la face vitr e et une paroi inflammable dans la diagonale doit tre au moins de 800 mm B La distance minimum de la sortie d air de convection et un plafond inflammable est de 500 mm La distance minimale respecter entre la face avant ou vitr du foyer et une paroi inflammable est de 1 m tre Si le conduit passe un mur inflammable respecter le DTU 24 2 C FIG A Si la chemin e est libre la distance entre l habillage et le mur inflammable doit tre au moins de 430 millimetres Lillustration montre la distance approximative entre le sol et le centre du trou pour la connexion avec le conduit de fumee Car le conduit est incline cette hauteur peut varier selon o l habillage est install Les alterations dans l etage et les murs peuvent influencer la hauteur Monter prealablement a sec la cheminee jusqu l l ment sup rieur avant de percer un trou dans le conduit Cela permet de trouver la bonne hauteur et la position convenable du tuyau de raccordement dans le conduit Montrer la position du trou quand le set pour l apport d air frais passe par le planc
14. cheibe der Feuerraumt r und brennbaren Gegenst nden betr gt 800 mm Isoliermaterial zwischen Kaminverkleidung und Hinterwand e Gr e der Bodenplatten vor dem Ger t falls notwendig e Rauchrohranschluss zwischen Brennkammer und Schornstein e Notwendige lsolierung falls das Rauchrohr durch eine Wand aus brennbarem Material gehen soll z B Holzwand Anschluss Wir empfehlen ein loses Zusammensetzen der Kaminverkleidung ohne Kleber damit Sie den Kamineinsatz in der H he einstellen k nnen bevor dieser an den Schornstein angeschlossen wird Verwenden Sie eine Wasserwaage um sicher zu stellen dass die Kaminverkleidung waagerecht aufgebaut wird Da sich der Kamineinsatz bei W rme ausdehnt darf die Verkleidung nicht auf dem Einsatz lasten oberhalb des Kamineinsatzes muss ein Spiel von 3 bis 5 mm sein Seitlich ist kein Spiel notwendig aber zwischen Unterkante des Einsatzes und der Gesimsplatte muss das Spiel mindestens 2 mm betragen Bodenplatte Bei hitzeunbest ndigem Bodenbelag muss das Ger t auf eine Bodenplatte aus nicht brennbarem Material gestellt werden Diese muss die Feuerraum ffnung vorn um 500 mm und seitlich um 300 mm berragen Pulverleim als Spachtelmasse Dieser wird bei Unebenheiten und Ausbesserungen der Betonelemente benutzt Mischen Sie den Kleber in Pulverform mit Wasser die Kleberkonsistenz soll Zahnpasta hneln Bevor Sie beginnen benetzen Sie die Betonoberfl che mit einem feuchten Sc
15. drawing In order to prevent condensation the leg can be filled with insulation Generelt om elementpejse Vagt Husejeren skal forsikre sig om at gulvet t ler belastningen i henhold til totalvaegten p pejsen Overvej eventuelt forstaerkning af gulvet specielt i nye huse og s fremt arealet under pejsen ikke har ekstra straer som understotter Ved montering p flydende tr gulv bor pejsen nedsaenkes for at undg at gulvet l ses og revner Brandmur Ved montering af ildsted op ad br ndbar v g skal der anvendes brandmur Vi anbefaler at anvende Nordmur brandmurselementer som giver en meget god beskyttelse af v ggen og har en byggetykkelse p kun 65 mm inklusiv 15 mm luftspalte Brandmur kan ogs bygges af andre stenmaterialer som gasbetonblokke eller mursten Minimumstykkelsen skal da v re 100 mm gasbetonblokke eller 108 mm mursten Brandmuren skal altid v re s hoj at afstanden fra r gr r r gklokke til br ndbart materiale bliver minimum 300 mm Fritst ende pejse kan monteres uden brandmur Overhold alle sikkerhedsafstande til brandbare materialer Tilslutning til skorsten Folg skorstensproducentens specifikationer for tilslutning til skorsten Prov forst at opstable omramningen uden at lime s findes den ngjagtige hgjde og position til indgangshullet i skorstenen Indsatsen ekspanderer under fyring og m ikke hvile p omramningen der skal vaere en afstand p minimum 3 mm Omramningen m heller
16. egen monteringsanvisning for indsatsen 6 Tokyo Indsats N 23G St lskorsten Kan monteres til st lskorsten V gt inkl indsats Tokyo 433 kg Tokyo Hgj 526 kg Tokyo Buet 440 kg Tokyo H j Buet 533 kg Tokyo Smal 423 kg Tokyo Smal Buet 430 kg Minimumsm l brandmur b x h flugt med v g Tokyo FIG 1 Tokyo Haj FIG 1 Tokyo Buet FIG 2 Tokyo H j FIG 2 1540 x 1600 mm 1540 x 1900 mm 1540 x 1890 mm 1540 x 2170 mm Tokyo Smal FIG 3 Tokyo Smal Buet FIG 4 1540 x 1900 mm 1540 x 2140 mm Udenp vag Tokyo FIG 1 Tokyo Hgj FIG 1 Tokyo Buet FIG 2 Tokyo Hgj Buet FIG 2 1250 x 1600 mm 1250 x 1900 mm 1250 x 1890 mm 1250 x 2190 mm Tokyo Smal FIG 3 Tokyo Smal Buet FIG 4 1250 x 1850 mm 1250 x 2140 mm Sikkerhedsafstande FIG 1 FIG 4 Sgrg for at de angivne sikkerhedsafstande ikke underskrides Sikkerhedsafstande kan variere fra land til land Folg instruktionerne p det sprog som g lder for det land hvor pejsen monteres Minimumsafstand fra glasset p indsatsen til brandbar v g er 570 mm B Minimumsafstand fra udluftventilen til brandbart materiale er 380 mm Minimumsafstand foran indsats bningen til brandbar bygningsdel eller inventar er 1 m FIG A Ved fritst ende placering skal afstand fra bagkant af omramningen til brandbar v g v re minimum 250 mm M let i tegningen angiver ca centrumhajden i hullet af r gr ret M let vil variere efter hvor o
17. eln Sie mit einer Kelle oder einem Pinsel Nachfolgend gl tten Sie die Oberfl che mit einem feuchten Schwamm oder Sandpapier Zu Ihrer eigenen Sicherheit halten Sie sich an die Montageanleitung Alle Sicherheitsabst nde sind Mindestabst nde Bei Installation Ihres Kamineinsatzes beachten Sie die l nderspezifischen rtlichen und baurechtlichen Vorschriften Vorbehaltlich Druckfehler und nderungen Beachten Sie die separate Montageanleitung f r den Kamineinsatz Tokyo Kamineinsatz N 23G Schornstein aus Stahlelementen Kann an einen Schornstein aus Stahlelementen an geschlossen werden Gewicht inkl Kamineinsatz Tokyo L 433 kg Tokyo H 926 kg Tokyo L Formhaube 440 kg Tokyo H Formhaube 933 kg Tokyo S 423 kg Tokyo S Formhaube 430 kg Sicherheitsabst nde FIG 1 Bitte die Sicherheitsabst nde einhalten Der Abstand zwischen Feuerraumtur und brennbaren Gegenst nden M bel muss mindestens 1 Meter betragen A Der Abstand zwischen Sichtscheibe der Feuerraumtur und einer Wand aus brennbarem Material muss mindestens 800 mm betragen B Der Abstand zwischen dem Konvektionsluftaustrittsgitter und Gegenst nden aus brennbarem Material muss mindestens 500 mm betragen C Wenn es sich um ein freistehendes Modell handelt muss der Abstand zwischen Kaminverkleidung und einer Wand aus brennbarem Material mindestens 430 mm betragen Die Abbildung zeigt den ungef hren Abstand vom Boden bis zur Mitte der ffnu
18. et la chemin e C est enti rement normal et ny pas de raison de s inqui ter Ces petites fissures peuvent tre enlev es en comblant avec du joint Grattez les par exemple avec un tournevis pour laisser davantage d espace aux joints et aspirez pour enlever toute la poussi re Injectez de l enduit acrylique et uniformisez l enduit avec le bout de votre doigt l g rement humidifi a l eau et au savon Apr s environ 24 heurs le joint peut tre repeint Des dommages plus petits Ceux ci sont avec succes r par s avec la colle poudre fournie Si les dommages sont profonds nous recommandons de remplir deux fois afin d viter de voir apparaitre un retyrait Remplissez les petites fissures et les surfaces inegales avec une truelle ou une brosse Lisser la surface avec une ponge humide ou du papier abrasif Pour votre s curit observez les instructions de montage loutes les distances de s curit sont des distances minimales L installation du foyer doit observer les regles et les reglements du pays ou installe Nordpeis AS n est pas responsable du montage defectueux d un foyer Nordpeis se reserve le droit de modifier sans preavis les caracteristigues techniques et dimensionnelles de ses produits NB Voir le manuel d installation separe pour le foyer Tokyo Foyer N 23G Conduit de fum e en acier Compatible avec un conduit d vacuation des fumees en acier Poids foyer inclut Tokyo Bas 433 kg Tokyo H
19. her Instructions d assemblage FIG 5 FIG 33 Tokyo Bas Tokyo Bas Hotte Courb e FIG5 gt Tokyo Haut Tokyo Haut Hotte Courb e FIG9 gt Tokyo Plat Tokyo Plat Hotte Courb e 19 gt FIG 5 FIG 9 FIG 19 Placez la plaque de fond a 90 avec le conduit des fum es mur afin de s assurer qu il est bien attach Faites les ajustements n cessaires avec du ciment colle et ou coins FIG 6 FIG 12 viter l espace entre l habillage et les triers dans l acier parce que cela peut causer les fissures dans les l ments de l habillage Mettre de la colle dans les triers dans pour viter quelque fissure possible FIG 15 FIG 22 Remplacer les pieds du foyer avec ceux qui sont inclus dans l emballage de Tokyo Si la chemin e est connect e une sortie des fum es sur le dessus le couvercle pour le d me de fum e doit tre d plac la sortie arri re FIG 16 FIG 23 Assurez vous d avoir de l espace entre le foyer et l habillage car le foyer se dilate avec la chaleur Lisez aussi la section du r glage FIG 18 FIG 25 FIG 29 Enlever le couvercle pour la sortie des fum es avec un l ger coup de marteau si le chemin est mont e lat ralement L apport d air accessoire Pour plus d informations voir les instructions d assemblage pour l apport d air frais FIG 32 Quand l apport d air est mont au travers d un mur un trou doit tre coup dans l habillage avec une meuleuse
20. hwamm Dieser entfernt Staub und sorgt fur bessere Haftung Verspachteln Sie mit der Masse eventuelle Unebenheiten und f llen Sie Risse 16 Akrylkleber Wird zum Verkleben der Elemente zum Ankleben an die Wand und zum F llen von Fugen benutzt Anstrich 24 Stunden nach der Montage k nnen Sie den Kamin anstreichen Verspachtelte Fl chen werden vorher mit feinem Schleifpapier geschliffen Verwenden Sie Latex Akrylfarbe Dispersionsfarbe Gesimsplatten aus Granit Marmor Reinigen Sie die Platten mit mildem Seifenwasser und entfernen Sie bersch ssige Kleberreste Eventuelle Haarrisse Neu gebaute H user k nnen in den ersten Jahren Senkungsrisse aufweisen Daher k nnte Ihr Kaminbausatz an den Klebestellen zwischen Betonelementen Brandschutzmauer und Schornstein kleine Risse bekommen Das ist v llig normal und kein Grund zur Besorgnis Kleine Risse k nnen durch Neuverfugung beseitigt werden Die Fuge mittels Fugenschaber auskratzen anschlie end entfernen Sie mit dem Staubsauger alle abfallenden Reste Spritzen Sie Akrylfugenmasse ein und verteilen Sie diese mit einer eingeseiften Fingerspitze Nach 24 Stunden kann die Fuge berstrichen werden Kleinere Besch digungen Diese werden bestens mit dem mitgelieferten Pulverleim ausgebessert Wenn die Besch digung tiefer ist empfehlen wir diese in zwei Durchg ngen zu verspachteln um neue Senkungsrisse zu vermeiden Kleine Haarrisse und andere Unebenheiten verspacht
21. ial r minst 300 mm Frist ende spis kan monteras utan brandmur Beakta alla s kerhetsavst nd till br nnbara material Anslutning till skorsten Folj skorstenstillverkarens specifikationer f r anslutning till skorsten Provmontera f rst omramningen utan att limma f r att hitta r tt h jd och l ge i f rh llande till ing ngsh let i skorstenen Insatsen expanderar under eldning och f r inte vila p omramningen Minsta avst nd mellan insats och omramning r 2 3 mm Omramningen f r inte heller vila p insatsen vare sig i verkanten eller p sidorna F lj monteringsanvisningarna f r det aktuella fabrikatet vid toppanslutning till st lskorsten Krav p eldstadplan vid br nnbart golv F r att skydda golvet mot eventuellt utfallande gl d skall spisinsatsen placeras p ett obr nnbart material Eldstadsplanet skall anordnas s det t cker 300 mm framf r spisinsatsen och 100 mm utmed vardera sida Observera att om spisen eldas med ppen lucka st ller detta andra krav p eldstadsplanet Eldstadsplanet kan best av natursten betong eller 0 7 mm st lpl t Lim Elementen ska limmas med medf ljande lim Se till att alla limytor r fria fr n damm F r b ttre vidh ftning kan ytorna tv ttas L t ytorna torka innan limmet stryks p N r kaminen r f rdigmonterad efterfyller mellanrummen mellan elementen med akryl och j mnar ut fogen med svamp eller finger med tv ll sning s att det blir en tydlig
22. ikke hvile p indsatsen i overkant eller i siderne Ved toptilslutning til st lskorsten henviser vi til det p gaeldende fabrikats monteringsvejledning Krav til gulvplade p brandbart gulv For at beskytte gulvet mod eventuelle gloder skal pejseindsatsen anbringes p et brandsikkert materiale Guldpladen skal monteres s den d kker 300 mm foran pejseindsatsen og 150 mm p hver side Bem rk venligst at hvis der fyres med ben l ge stiller det andre krav til gulvpladen Da skal gulvpladen d kke 500 mm foran indsatsens l ge og 150 mm udad til hver af siderne Brug af gnistfang anses ikke som lukket fyring Gulvpladen kan best af natursten beton eller 0 7 mm st lplade Lim Elementerne skal limes med den medfglgende lim Sorg for at alle limflader er frie for stov For bedre haeftning kan overfladerne vaskes Lad overfladen torre for limen stryges p N r pejsen er faerdig monteret efterfyld mellemrummene mellem elementerne med akryl og udj vn fugen med en s bev d svamp eller finger s der bliver en tydelig fordybning mellem elementerne FIG 2 Maling Maling kan udf res s snart limfugerne er t rre Brug kun diffusions ben maling akryl beregnet til murv rk Dersom du nsker struktur kan der blandes lidt fliselim i malingen Behandling af marmor Reng r pladerne med mildt s bevand og fjern evt alle limrester Ridser i m rk marmor kan evt farves med blyantbly Et stensenter kan v re behj lpelig
23. illage est monte droit Le foyer se dilate pendant l utilisation c est pourquoi il ne doit pas sappuyer sur l habillage Au dessus et au dessous du foyer il doit y avoir un espace de 3 5 mm Lateralement il n y a aucun besoin de espaces Plaque de sol Une plaque de sol ignifug doit tre mis devant la chemin e si le sol est d une mati re combustible Colle en poudre pour remplir Utilise pour r parer des encoches ou fissures dans le b ton M langez la colle avec de l eau la consistance de la colle devrait tre celle de la p te dentifrice Avant de commencer il est recommand de laver les surfaces qui seront coll es avec une torchon humide pour assurer une meilleure adh rence et qu il ait pas de poussi re Remplissez vous toutes les surfaces in gales Colle acrylique Ceci est employ pour coller des l ments vers le mur et les coller ensemble et pour remplir des joints 12 Peinture L habillage peut tre peint 24h apr s qu il ai assembl Toute surface qui a t remplie doit tre liss avec du papier abrasif fin Utilisez des peintures latex ou acrylique peinture mulsion Marbre Granit Nettoyez les plaques avec de l eau l g rement savonneuse et enlevez toute colle restante Fissures Minces Les fondations de maisons neuves se tassent au cours des premi res ann es Par ailleurs des fissures tr s minces pourraient appara tre dans les joints entre les l ments le pare feu
24. imento poich si dilata con il calore Leggere la sezione sul posizionamento FIG 18 FIG 25 FIG 29 Rimuovere delicatamente il coperchio del tubo fumi se il camino collegato lateralmente Presa d aria esterna accessorio Per maggiori informazioni vedere le relative istruzioni di montaggio FIG 32 Quando la presa d aria esterna passa attraverso un muro bisogna praticare un foro nel rivestimento con una smerigliatrice ad angolo per collegare lateralmente il tubo FIG 33 Quando la presa d aria esterna arriva attraverso Il pavimento il tubo passa all interno del banco sui modelli Tokio High Low Sul modello Tokio Slim invece il foro gi esistente in uno dei piedini Per prevenire la condensazione il piedino pu essere riempito con materiale isolante Gr 15 Allgemeine Information Alle unsere Kaminverkleidungen sind aus nicht brennbarem Material Alle unsere Kamineins tze und fen sind gepr ft und entsprechen den neuesten Europ ischen Sicherheitsvorschriften Da in Europa je nach Land unterschiedliche Sicherheitsvorschriften bei der Installation von Feuerst tten gelten sind Sie als Endkunde f r die Einhaltung dieser Standards in Ihrer Gegend und die korrekte Installation des Ger tes selbst verantwortlich Nordpeis Northstar haftet nicht f r unsachgem e Installation Bitte halten Sie sich an Ihre lokalen Brandvorschriften betreffend e Sicherheitsabstand gemessen zwischen Sichts
25. l ga i insats till br nnbar v gg r 5 0 mm B Minimiavst nd fr n varmluftsutsl pp till br nnbart material r 380 mm Minimiavst nd fr n insatsens ppning till br nnbar byggnadsdel eller inredning r 1 m C FIG A Vid frist ende montering r minsta avst nd fran omramningens bakkant till br nnbar v gg 250 mm M ttet i skissen anger ungef rlig centrumh jd f r h let f r r kr ret M ttet varierar beroende p var omramningen placeras utifr n r kr rets stigning Lutande golv och v ggar kan ocks p verka m tten SE Provmontera f rst omramningen upp till spiselhyllan utan att limma f r att hitta r tt h jd och l ge i f rh llande till ing ngsh let i skorstenen M rk ocks upp eventuellt h l f r tillf rsel av uteluft genom golvet tillbeh r Montering FIG 5 FIG 33 Tokyo Tokyo B jd FIG5 gt Tokyo H g Tokyo H g B jd FIG9 Tokyo Smal Tokyo Smal B jd FIG19 F re montering b r sugande ytor oputsad Leca Scanpor Siporex etc putsas limtv ttas eller fuktas f r att undvika att akryllimmet torkar ut FIG 5 FIG 9 FIG 19 Bottenplattan 1 placeras v g och monteras i 90 i f rh llande till skorsten brandmur Justera eventuellt med kilar eller kakellim FIG 6 FIG 12 F r att betongomramningen inte skall spricka m ste glipor vid b rj rnet undvikas Anv nd ett tjockt lager lim f r att s kerst lla inga glipor uppst r FIG 15 FIG 2
26. ly instructions FIG 5 FIG 33 Tokyo Tokyo Curved FIG5 Tokyo High Tokyo High Curved FIG9 gt Tokyo Slim Tokyo Slim Curved 19 gt FIG5 FIG9 FIG 19 Place the bottom plate in 90 relative to the chimney wall to ensure that it is fastened properly If needed adjust with wedges or powder glue FIG 6 FIG 12 To prevent the concrete from cracking fill concrete paste on top of the carrying steel to avoid any possible gap FIG 15 FIG 22 Replace the legs of the insert with the ones included in the packaging of Tokyo If the fireplace is connected to a chimney at the top the smoke lid must be moved to the rear flue outlet FIG 16 FIG 23 Make sure there is a gap between the Insert and the surround as the insert expand with heat Also read the section about adjustment FIG 18 FIG 25 FIG 29 Gently knock out the perforation for the flue if the fireplace is mounted laterally Fresh air supply accessory See also separate assembly instructions for fresh air supply FIG 32 When connecting the fresh air supply through a wall it is necessary to make a hole in surround with an angle grinder so that the pipe can be inserted from the side FIG 33 When connecting the fresh air supply through the floor on Tokyo High and Low the pipe is conducted along the inside of bench In Tokyo Slim there is already a hole in one of the legs through which the pipe is conducted also defined on the dimensioned
27. med forskellige produkter til overfladebehandling af sten Spr kker Normalt vil nye huse f betydelige s tninger de f rste r derudover krymper alle betonelementer i aftagende grad de f rste 15 m neder Resultatet er at din elementpejs kan spr kke i fugerne mellem elementerne brandmur og skorsten S dan g r du Brug pejsen i nogle m neder Dersom den spr kker rids spr kken op med f eks en skrutr kker for at give bedre plads til fugemasse og st vsug for at fjerne alt st v Spr jt akryl fugemasse ind og udj vn massen med en s bev d fingerspids Efter et par d gn kan fugen overmales Sm skader Efter lang transport kan det ske at din pejs har f et en mindre skade De fleste skader kan dog enkelt repareres med vedlagte cementlim og spartelmasse Hvis skaden er dyb anbefales det at man spartler i to omgange for at undg s tning Mindre skader og uj vnheder spartler du med almindelig sandspartelmasse Efter et stykke tid kan du udj vne med en fugtig svamp For din egen sikkerhed f lg monteringsvejledningen Alle sikkerhedtsafstande er minimumsafstande Installation af ildsteder skal i till g udf res i henhold til det enkelte lands love og regler Nordpeis AS er ikke ansvarlig for fejlmontering af ildstedet Vi tager forbehold om trykfejl og aendringer For senest opdaterede version og mere fyldestg rende information om brandmur skorstenstilslutning etc se vore netsider www nordpeis eu NB Se
28. mm Tokyo Korkea Kaareva KUVA 2 1540 x 2190 mm Tokyo Pieni KUVA 3 1540 x 1850 mm Tokyo Pieni Kaareva KUVA 4 1540 x 2140 mm Ulkopuolinen Tokyo KUVA 1 1250 x 1600 mm Tokyo Korkea KUVA 1 1250 x 1900 mm Tokyo Kaareva KUVA 2 1250 x 1890 mm Tokyo Korkea Kaareva KUVA 2 1250 x 2190 mm mm mm Tokyo Pieni KUVA 3 1250 x 1850 Tokyo Pieni Kaareva KUVA 4 1250 x 2140 Turvaet isyydet KUVA 1 Varmista ettei annettuja turvaet isyyksi aliteta Turvaet isyydet vaihtelevat maittain Noudata asennusmaan kielell kirjoitettuja ohjeita A Minimiet isyys tulipes ss palavan liekin ja tulenaran sein n v lill on 570 mm B Minimiet isyys l mminilmaritil st tulenarkaan sein n on 380 mm Minimiet isyys tulipes n aukosta tulenarkaan rakenteeseen tai esineeseen on 1 metri C KUVAA Jos takkaa ei sijoiteta palomuuria vasten minimiet isyys takan kuoresta tulenarkaan sein n on 250 mm Piirustuksen mitat ilmaisevat savuputken vaipan keskikorkeuden noin Mitat vaihtelevat riippuen siit mihin kuori asennetaan savuputken nousun vuoksi My s lattian ja sein n vinous vaikuttaa mittoihin Kokeile ensin asentaa kuori ilman liimaa N in l yd t savupiipun aukon tarkan korkeuden ja sijainnin Merkitse my s mahdollinen lattiaan tuleva eik paloilmaliit nn lle lis varuste Asennus KUVA 5 KUVA 33 Tokyo Tokyo Kaareva FIG5 Tokyo Korkea Tokyo Korkea Kaareva FIG9 gt Tokyo Pieni Tokyo
29. mramningen placeres grundet stigningen p r gr ret Sk vheder i gulv og v gge vil ogs p virke m lene Pr v f rst at opstable omramningen op til pejsehylden uden at lime s findes den n jagtige h jde og position til indgangshullet i skorstenen Mark r ogs eventuelt hul til frisklufttilf rsel gennem gulv tilbeh r Montering FIG 5 FIG 33 Tokyo Tokyo Buet FIG5 Tokyo H j Tokyo H j FIG9 gt Tokyo Smal Tokyo Smal Buet FIG 19 F r montering b r sugende flader upudset Leca Scanpor Siporex etc pudses limvaskes eller fugtes for at undg udt rring af akryllim FIG 5 FIG 9 FIG 19 Bundpladen s ttes i vater og monteres i 90 i forhold til skorsten brandmur Juster eventuelt med kiler eller fliselim OBS Ved brug af Nordpeis gennemf ringselement m baenken placeres min 20 mm fra brandmuren FIG 6 FIG 12 For at undg at betonomramningen kn kker skal mellemrum til b rejernet forhindres P f r et godt lag fliselim for at sikre at b ringen har kontakt FIG 15 FIG 22 Udskift indsatsbenene med de ben som er pakket med beton omramningen Ved topmontering Skru l get p toppen af og monter det p r gstudsen bag p indsatsen FIG 167 FIG 23 Husk afstand mellem indsatsen og omramningen da indsatsen ekspanderer under fyring L s ogs afsnittet om tilslutning til skorsten FIG 18 FIG 25 FIG 29 Ved sidemontering bank forsigtigt udsparingen til r gr ret ud F
30. n Sie mit dem Winkelschleifer ein Loch in die Kaminverkleidung sodass das Rohr seitlich eingezogen werden kann FIG 33 Wenn das Zuluftkit durch den Boden angeschlossen wird ziehen Sie das Rohr bei Tokyo High und Tokyo Low entlang der Innenseite der Bank ein Bei Tokyo S gibt es bereits ein Loch in einem der Beine durch welches das Rohr gef hrt wird siehe Abbildung Um eine Kondensation zu vermeiden kann das Bein mit Isolierung gef llt werden 17 700 480 1150 1320 1600 1620 1900 1 gt 1540 m gt 1000 a gt 1250 m Wes 9161 GLOL m m 006 L lt 009L lt GCEL 9C9L 006 L lt 009L lt Tokyo Buet Tokyo Curved Tokyo B jd Tokyo Kaareva Tokyo Hotte Courbee Tok
31. ng in den Schornstein Die H he des Rauchrohres h ngt von der Position des Kamineinsatzes ab Stellen Sie die Kaminverkleidung lose bis zum Gesims auf um Position und H he des Rauchrohranschlusses anzuzeichnen Markieren Sie auch gleich ein Loch im Boden falls Sie ein Zuluftkit anschlieRen m chten Zubeh r Aufbauanleitung FIG 5 FIG 33 Tokyo Tokyo Formhaube FIG 5 Tokyo High Tokyo High Formhaube FIG 9 Tokyo Slim Tokyo Slim Formhaube FIG 19 FIG 5 FIG 9 FIG 19 Montieren Sie die Basisplatte waagerecht im 90 Winkel zur Wand Schornstein Falls notwendig behelfen Sie sich mit Keilen oder Pulverleim FIG 6 FIG 12 Fur optimale Haftung und um Risse in der Verkleidung zu verhindern bedecken Sie die Stahltr ger mit Fliesenkleber FIG 15 FIG 22 Ersetzen Sie die Standbeine des Kamineinsatzes mit denen die der Verpackung vom Tokyo beiliegen Bei Anschluss oben muss der Deckel des Rauchstutzens nach hinten ummontiert werden FIG 16 FIG 23 Da sich der Kamineinsatz beim Einheizen ausdehnt muss ein Abstand zwischen Einsatz und Verkleidung bestehen Lesen Sie auch den Abschnitt ber Anschluss an den Schornstein FIG 18 FIG 25 FIG 30 Bei seitlicher Montage schlagen Sie vorsichtig die Perforierung f r das Rauchrohr aus Zuluftkit Zubeh r F r weitere Informationen halten Sie sich an die eigene Montageanleitung des Zuluftkits FIG 32 Wenn das Zuluftkit durch die Wand angeschlossen wird arbeite
32. ng the installation in your region country Nordpeis Northstar is not responsible regarding correct installation You should check local regulations concerning distance from firebox to combustible flammable materials e insulation materials reguirements between fireplace surround and back wall size of floor plates in front of fireplace stove if reguired fluepipe connection between firebox and chimney e insulation requirements if fluepipe goes through flammable wall such as a wood wall Adjustment We recommend to stack the surround without glue in order to adjust the insert prior to perforating the chimney for the flue connection Use a spirit level to ensure that the surround is mounted straight The insert will expand with heat and for this reason the surround must not rest on the insert Above the insert there must be a gap of 3 to 5 mm Laterally there is no need for gaps but between the lower part of the insert and the surround there must be a gap of at least 2 mm Floor plate A fireproof floor plate must be put in front of the fireplace if the floor is of a combustible material Powder glue for filling This is used to repair any notches or wounds in the concrete Mix the provided powder glue with water the consistency of the glue should be that of tooth paste Before you start use a damp sponge to wet the concrete surface This will remove dust and provide for better adhesion Fill in any uneven surfaces
33. ponsible for wrongly assembled inserts We accept no liability for typographical errors and changes NB See separate instructions for the insert Tokyo Insert N 23G Steel chimney Can be installed with steel chimney Weight including insert Tokyo 433 kg Tokyo High 926 kg Tokyo Curved 440 kg Tokyo High Curved 533 kg Tokyo Slim 423 kg Tokyo Slim Curved 430 kg Safety distances FIG 1 FIG 4 Ensure that the safety distances are complied with Please note that these safety distances can vary from country to country A The distance from the glass of the insert to inflammable wall must be at least 800 mm B The distance between the top of the convection air outlet and roof of inflammable material must be at least 500 mm FIG A If the fireplace is mounted free standing the minimum distance from the back of the surround to inflammable wall must be at least 430 mm The distance from the door of the insert to inflammable materials furniture must be at least 1 m The illustration indicates the approximate center height of the hole for the flue As the flue is inclining this height will vary depending on where the surround Is installed Distortions in floors and walls may also influence the height Dry stack the fireplace until the mantelpiece element for accurate height and positioning of the flue chimney connection If a fresh air supply set is connected through the floor mark where the hole should be Assemb
34. risklufttilf rsel tilbeh r Se ogs s rskilt monteringsanvisning for friskluftstilf rsel FIG 32 Ved montering af frisklufttilf rsel gennem v ggen skal der laves hul i betonomramningen med en vinkelsliber s r ret kan f res ind fra siden FIG 33 Ved montering af frisklufttilf rsel gennem gulv f res r ret op langs indersiden af b nken p Tokyo H j Lav P Tokyo Smal f res r ret ind i det eksisterende hul i et af benene ogs angivet p m ltegningen Mont r f rst friskluftr ret og s betondelene Benet kan fyldes med isolering for at forhindre kondens Allm nt om elementspisar Tyngd Fastighets garen ska f rs kra sig om att golvet t l belastningen av spisens totalvikt verv g eventuellt f rst rkning av golvet speciellt i nya hus och om det inte finns n gra bj lkar d r spisen ska st Vid montering p flytande tr golv b r spisen s nkas ned f r att undvika att golvet blir l st och spricker Brandmur Vid montering av eldstad invid br nnbar v gg ska brandmur anv ndas Vi rekommenderar att Nordmur brandmurselement anv nds Dessa ger mycket bra skydd av v ggen och r endast 65 mm tjocka inklusive 15 mm luftspalt Brandmur kan ven byggas av andra stenmaterial s som gasbetongblock eller mursten Minimitjockleken ska d vara 100 mm l ttbetong respektive 120 mm massivt tegel Brandmuren ska alltid vara s h g att avst ndet fr n r kr r r kklocka till br nnbart mater
35. rna Alla s kerhetsavst nd r minimiavst nd Installation av eldst der ska dessutom utf ras i enlighet med varje enskilt lands lagar och f reskrifter Nordpeis AS r inte ansvarigt om eldstaden monterats fel Vi reserverar oss f r tryckfel och ndringar P v r hemsida www nordpeis eu finns senast uppdaterade version och ytterligare information om brandmurar skorstensanslutning etc Obs Se egen monteringsanvisning f r insatsen 8 SE Tokyo Insats N 23G St lskorsten Kan anslutas till st lskorsten Vikt inklusive insats Tokyo 433 kg Tokyo H g 926 kg Tokyo B jd 440 kg Tokyo H g B jd 533 kg Tokyo Smal 423 kg Tokyo Smal B jd 430 kg Minimim tt brandmur b x h Inf lld Tokyo FIG 1 Tokyo H g FIG 1 Tokyo B jd FIG 2 Tokyo H g B jd FIG 2 1540 x 1600 mm 1540 x 1900 mm 1540 x 1890 mm 1540 x 2190 mm Tokyo Smal FIG 3 Tokyo Smal B jd FIG 4 1540 x 1850 mm 1540 x 2140 mm Utanp liggande Tokyo FIG 1 Tokyo H g FIG 1 Tokyo B jd FIG 2 Tokyo H g B jd FIG 2 1250 x 1600 mm 1250 x 1900 mm 1250 x 1890 mm 1250 x 2190 mm Tokyo Smal FIG 3 Tokyo Smal B jd FIG 4 1250 x 1850 mm 1250 x 2140 mm S kerhetsavst nd FIG 1 FIG 4 S kerst ll att angivna s kerhetsavst nd inte underskrids S kerhetsavst nden kan variera fr n land till land F lj anvisningarna p det spr k som g ller f r det land d r spisen monteras A Minimiavst nd fr n
36. sia installato Inclinazioni delle pareti e dei pavimenti e le distanze rispetto al centro del tubo fumi possono influire sulle dimensioni complessive Si raccomanda di effettuare un premontaggio a secco dei componenti per verificare l esatta posizione del punto di collegamento alla canna fumaria e di effettuare solo successivamente il montaggio definitivo usando gli appositi collanti Mostrare la posizione del foro nel caso ll set per la presa d aria esterna sia collegato attraverso il pavimento Istruzioni per il montaggio FIG 5 FIG 33 Tokyo Low Tokyo Low Cappa Curvata FIG5 gt Tokyo High Tokyo High Cappa Curvatta FIG9 gt Tokyo Slim Tokyo Slim Cappa Curvatta FIG 19 gt FIG 5 FIG 9 FIG 19 Posizionare il piatto inferiore a 909 rispetto al camino parete per garantire che sia fissato correttamente Se necessario regolare con i cunei o la colla adesiva FIG 6 FIG 12 Evitare fessure fra il rivestimento e le staffe in acciaio poich queste possono causare crepe negli elementi del rivestimento Mettere colla cementizia sulle staffe in acciaio per evitare ogni possibile fessura FIG 15 FIG 22 Sostituire le gambe dell inserto con i piedini inclusi nell imballaggio del rivestimento Tokyo Se il camino collegato ad un uscita fumi superiore il tappo di chiusura della cappa fumi deve essere spostato sull uscita posteriore FIG 16 FIG 23 Assicurarsi che ci sia uno spazio fra l inserto ed il rivest
37. sizione esatta in cui eseguire il foro per la canna fumaria Utilizzare una livella per assicurare che il rivestimento sia montato dritto Linserto quando acceso subisce delle forti dilatazioni che potrebbero propagarsi alle strutture del rivestimento Per questi motivi importante che le due strutture del rivestimento e dell inserto siano fra loro indipendenti Sopra l inserto ci deve essere uno spazio di 3 a 5 mm Lateralmente non c nessun necessit di spazio ma tra la parte inferiore dell inserto e il rivestimento ci deve essere uno spazio di almeno 2 mm Piastra pavimento Se il pavimento di materiale infiammabile deve essere montata davanti al camino una piastra salvapavimenti di materiale ignifugo Colla in polvere per riempire Usare la colla per riparare qualsiasi foro fessura e crepa nel cemento Mescolare la colla in polvere con acqua la consistenza della colla dovrebbe essere quella del dentifricio Prima di iniziare usare una spugna umida per bagnare la superficie del cemento Ci rimuover la polvere e favorir una migliore adesione Riempire tutte le superfici irregolari Adesivo acrilico E usato per incollare gli elementi verso il muro o tra di loro e per riempire giunture 14 Pittura Il rivestimento pu essere dipinto 24 ore dopo che stato assemblato Le superfici che sono state riempite devono essere lisciate con la carta abrasiva Usare uno smalto traspirante a base acrilica o lattice
38. t b ringen har kontakt FIG 15 FIG 22 Bytt ut innsatsbena med bena som er pakket med betongomrammingen Ved topptilslutning til pipe m royklokket flyttes til bakre r ykuttak FIG 16 FIG 23 Husk avstand mellom innsatsen og omrammingen da innsatsen ekspanderer under fyring Les ogs avsnittet om tilkobling til pipe FIG 18 FIG 25 FIG 29 Ved sidemontering m utsparing til r ykr ret forsiktig bankes ut Friskluftstilf rsel tilbeh r Se ogs egen monteringsanvising for friskluftstilf rsel FIG 32 Ved montering av friskluftstilf rsel gjennom vegg m det lages hull i betongomrammingen med en vinkelsliper slik at r ret kan f res inn fra siden FIG 33 Ved monterning av friskluftstilf rsel gjennom gulv f res r ret opp langs innsiden av benken p Tokyo H y Lav P Tokyo Smal f res r ret inn i eksisterende hull i et av benene ogs m lsatt p m ltegningen Monter f rst friskluftr ret og tre deretter p betongdelene Benet kan fylles med isolasjon for forhindre kondens General information Our surrounds are all made of non combustible materials All our inserts stoves are tested according to the latest European reguirements and also to the Norwegian SINTEF standard which includes particle tests Several European countries however have individual rules for installation of inserts stoves and fireplaces You as a client are totally responsible for the fulfilling of these local rules concerni
39. tallato Nordpeis AS non responsabile per inserti indebitamente assemblati Non assumiamo nessuna responsabilit per errori tipografici e modifiche arbitrarie NB Vedere le istruzioni separate per l inserto Tokyo Inserto N 23G Canna fumaria Pu essere montato con una canna fumaria d acciaio Peso inserto incluso Tokyo Low 433 kg Tokyo High 926 kg Tokyo Low Cappa Curvata 440 kg Tokyo High Cappa Curvatta 533 kg Tokyo Slim 423 kg Tokyo Slim Cappa Curvata 430 kg Distanze di sicurezza FIG 1 Assicurarsi che le distanze di sicurezza non siano inferiori a guelle richieste nei successivi dati tecnici Si prega di notare che gueste distanze di sicurezza possono variare da paese a paese A E consigliabile mantenere una distanza di almeno 800 mm misurati diagonalmente tra il vetro della porta ed il muro laterale B La distanza minima fra la presa d aria di convezione e un tetto di materiali infiammabili deve essere almeno 500 mm La distanza minima fra dell inserto ed eventuali pareti o mobili infiammabili deve essere di almeno un metro C FIG A Quando viene montato in modo indipendente la distanza minima fra la parte posteriore del rivestimento ed un muro infiammabile deve essere di almeno 430 mm Lillustrazione mostra la distanza approssimativa fra il pavimento e il centro del foro nel camino Come il tubo fumi inclinato guest altezza varier dipendendo su dove il rivestimento
40. ten pit k ytt palomuuria Suosittelemme Nordmur palomuurielementtej jotka suojaavat sein eritt in hyvin ja joiden rakennepaksuus on vain 65 mm sis lt en 15 mm n ilmaraon Palomuuri voidaan rakentaa muistakin kivimateriaaleista kuten kevytbetonista tai tiilist Minimipaksuus on silloin 100 mm kevytbetoni tai 120 mm umpitiili Palomuurin pit aina olla niin korkea ett savuputken et isyys tulenarasta materiaalista on v hint n 300 mm Vapaasti seisovat takat voidaan asentaa ilman palomuuria Noudata kaikkia turvet isyyksi tulenarkaan materiaaliin Liitt minen hormiin Noudata savupiipun valmistajan liitt mist koskevia ohjeita Kokeile ensin pystytt kuori ilman liimaa jotta l yd t savupiipun liit nt rei n tarkan korkeuden ja sijainnin Tulipes laajenee l mmitett ess Siksi se ei saa lev t kuoren varassa vaan tulipes n ja kuoren v liss pit olla v hint n 3 mm rako Kuori ei saa my sk n lev t tulipes n yl reunan tai kylkien varassa Liitett ess takka yl sp in ter ssavupiippuun pit noudattaa valmistajan asennusohjeita Tulenaralla lattialla olevalle eduslaatalle asetettavat vaatimukset Tulipes on asetettava tulenkest v lle materiaalille joka suojaa lattiaa mahdollisilta ulos lent vilt hehkuvilta kek leilt Eduslaatan pit edess ulottua tulipes n ulkopuolelle 300 mm ja kummallakin puolella 100 mm Jos takkaa l mmitet n luukku a
41. tsen til brennbar vegg er 570 mm B Minimumsavstanden fra utluftingen til brennbart materiale er 380 mm FIG A Ved frittst ende plassering skal avstand fra bakkant omramming til brennbar vegg v re minimum 250 mm Minimum avstand fra roykror roykklokke til brennbar vegg er 300 mm Dersom r ykr ret skal f res gjennom brennbar vegg m det mures minimum 230 mm murverk mellom r r og brennbar vegg M let i tegningen angir ca senter h yde for hull til r ykr ret M let vil variere etter hvor omrammingen blir plassert grunnet stigning p r ykr r Skjevheter i gulv og vegger vil ogs p virke m lene T rrstable peisen til og med peishyllen for n yaktig h yde og posisjon til r ykinnf ringen Merk ogs opp eventuelt hull til friskluftsett gjennom gulv tilbeh r Montering FIG 5 FIG 33 Tokyo Tokyo Buet FIG5 Tokyo H y Tokyo H y Buet FIG9 Tokyo Smal Tokyo Smal Buet 19 For montering bor sugende flater upusset Leca Scanpor Siporex etc pusses limvaskes eller gyses for uttgrring av akryllim FIG5 FIG9 FIG 19 Bunnplaten skal monteres i 90 forhold til pipe brannmur for unng glippe Juster evt med kiler eller sementlim OBS Ved bruk av Nordpeis gjennomf ringselement m benken plasseres min 20 mm fra brannmuren FIG 6 FIG 12 For unng at betongomrammingen knekker m glippe til baerejernet forhindres P for et godt lag med fliselim for sikre a
42. vattuna eduslaatan vaatimukset muuttuvat Eduslaatta voi olla luonnonkive betonia tai 0 7 mm paksua pelti Liima Elementit pit liimata mukana toimitetulla liimalla Varmista ett kaikki liimapinnat ovat p lytt mi Tartunnan parantamiseksi yl pinnat voidaan pest Anna pinnan kuivua ennen liiman levitt mist Kun takka on koottu t yt elementtien v liset raot akryylill ja tasoita saumat saippuaveteen kastetulla sienell tai sormella niin ett elementtien v liin j selke syvennys kuva Z Maalaus Takka voidaan maalata heti kun liimasaumat ovat kovettuneet K yt vain tiilen maalaukseen tarkoitettua diffuusion l p isev maalia akryyli Jos haluat struktuuripinnan voit sekoittaa maaliin hieman kiinnityslaastia Marmorin k sittely Puhdista levyt miedolla saippuavedell ja poista mahdolliset liimanjaanteet Tummassa marmorissa olevat naarmut voi peitt lyijykyn ll Lis tietoa kiven pintak sittelytuotteista saat kivimyym l ist Halkeamat Uudet talot painuvat merkitt v sti ensimm isten vuosien aikana Lis ksi kaikki betonielementit kutistuvat merkitt v sti ensimm isten 15 kuukauden aikana T m n seurauksena elementtien palomuurien ja savupiipun v liset saumat saattavat halkeilla Toimi n in k yt takkaa muutaman kuukauden ajan Kun sauma halkeaa avaa sauma esim ruuvitaltalla jotta saat enemm n tilaa saumausmassalle ja imuroi p lytt m ksi Purista saumaan akr
43. vstander Installasjon av ildsteder m i tillegg v re i henhold til det enkelte lands lover og regler Nordpeis AS st r ikke ansvarlig for feilmontering av ildstedet Vi tar forbehold om trykkfeil og endringer For sist oppdaterte versjon og mer utfyllende informasjon om brannmurer pipetilkobling etc se v re nettsider www nordpeis no 2 Tokyo Innsats N 23G St lpipe Kan monteres med st lpipe Vekt inkl innsats Tokyo 433 kg Tokyo Hoy 526 kg Tokyo Buet 440 kg Tokyo Hay Buet 933 kg Tokyo Smal 423 kg Tokyo Smal Buet 430 kg Minimumsm l brannmur b x h I flukt med vegg Tokyo FIG 1 Tokyo Hoy FIG 1 Tokyo Buet FIG 2 Tokyo H y Buer FIG 2 1540 x 1600 mm 1540 x 1900 mm 1540 x 1890 mm 1540 x 2190 mm Tokyo Smal FIG 3 Tokyo Smal Buet FIG 4 1540 x 1850 mm 1540 x 2140 mm Utenp vegg Tokyo FIG 1 Tokyo Hoy FIG 1 Tokyo Buet FIG 2 Tokyo Hay Buer FIG 2 1250 x 1600 mm 1250 x 1900 mm 1250 x 1890 mm 1250 x 2190 mm Tokyo Smal FIG 3 Tokyo Smal Buet FIG 4 1250 x 1850 mm 1250 x 2140 mm Minimumsdybde p gulvplate 300 mm Sikkerhetsavstander FIG 1 FIG 4 Sgrg for at angitte sikkerhetsavstander ikke underskrides Sikkerhetsavstander kan variere fra land til land Folg instruksjonene p det spr ket som gjelder for landet peisen monteres i Minimum avstand foran innsats pning til brennbar byggningsdel eller innredning er 1 m A Minimum avstand fra glasset p innsa
44. yo Cappa Curvatta Tokyo Formhaube mm 1320 1890 1620 2190 1150 20 gt 1250 2L a 21000 gt 1890 gt 2190 1625 1325 gt 1540 CC B gt 1890 gt 2190 1615 1315 Tokyo Smal Tokyo Slim Tokyo Pieni Tokyo Plat Tokyo S mm 240 480 1850 1570 750 22 m gt 1850 1580 1850 1570 Le 23 Tokyo Smal Buet Tokyo Slim Curved Tokyo Smal B jd Tokyo Pieni Kaarev
45. yylisaumamassaa ja tasoita esim saippuaan kastetulla sormenp ll Muutaman p iv n p st sauman voi ylimaalata Pienet vauriot Pitk n kuljetuksen j lkeen takassasi saattaa olla pieni vaurioita Useimmat vauriot on kuitenkin helppo korjata mukana toimitetulla sementtiliimalla ja tasoitteella Jos vaurio on syv suosittelemme ett tasoitat kahteen kertaan painumisen v ltt miseksi Pienet vauriot ja ep tasaisuudet voit tasoittaa tavallisella tasoitemassalla Odota v h n aikaa ja tasoita kostealla sienell Noudata asennusohjetta turvallisuutesi vuoksi Kaikki turvaet isyydet ovat minimiet isyyksi Tulisijan asennus pit suorittaa maakohtaisten lakien ja m r ysten mukaan Nordpeis AS ei vastaa tulisijan virheellisest asennuksesta johtuvista vaurioista Emme vastaa painovirheist ja pid t mme oikeudet muutoksiin Uusimmat versiot ja yksityiskohtaiset tiedot palomuureista savupiippuliit nn st jne l yd t internetsivuiltamme www nordpeis eu Huom Katso erillinen asennusohje tulipes lle 10 Tokyo Tulipes N 23G Ter ssavupiippu Voidaan liitt ter ssavupiippuun Paino sis lt en tulipes n Tokyo 433 kg Tokyo Korkea 926 kg Tokyo Kaareva 440 kg Tokyo Korkea Kaareva 933 kg Tokyo Pieni 423 kg Tokyo Pieni Kaareva 430 kg Palomuurin minimimitat I x k Upotettu Tokyo KUVA 1 1540 x 1600 mm Tokyo Korkea KUVA 1 1540 x 1900 mm Tokyo Kaareva KUVA 2 1540 x 1890