Home

Ditec Smart Reset

image

Contents

1. 089 Hd LH LAB4ASR LAB4ASRY K sse 250 180 MECHANICAL INSTALLATION DRAWINGS PACKING LIST Left column Right column Left Cover Right Cover Transom with rolled curtain K22 Motor Control unit Hardware box ODT833 2015 05 27 24 CURTAIN INSTRUCTION 25 ODT833 2015 05 27 CONTENTS Chap TOPICS 1 AAA GENERAL SAFETY PRECAUTIONS EE 26 2 TECHNICAL CHARACTERISTICS nnne nnne 27 3 MECHANICAL INSTALLATION 3 1 Checking the opening iei ete ER E eie id rte dt bn aee t 28 3 2 Fitting the Tee LEET 28 3 3 Installation of the rolling shaft ss 28 3 4 Gearmotor installation 22 28 3 5 Installation of the Safety Linear Encoder SLEC aaaaaiaaaaaaaaaaassaaaaassaaaaassannnasnaannanaaia 28 3 6 Positioning the CUrteln tn tended
2. 28 3 7 Installing the photocells when foreseen a 28 4 ELECTRIC CONNECTIONS 4 1 Comtroli panel BEE 29 4 2 Connecting the control panel automation iaaaaaaaaaaassaasnassannnasnsannasasananassannnasnannaani 29 4 3 Salely PNO Ice E 29 5 ELECTRONIC CONTROL PANEL EE Te 30 5 2 47E Inverter Connectlons 2 2 Ert sn act dea 34 6 ADJUSTING AND STARTING 6 1 Adjustment of the Safety Linear Encoder SLEC enn 38 6 2 Tensioning adjustment of the curtain KAK KKKKK NN KAKAK KK K KK KKR K K KK KK KAK AUD 38 7 TROUBLESHOOTING e nro cete c OY ER TER Re dua eina rires tan ga deut 39 8 LE ggdyledcpc alara 40 1 GENERAL SAFETY PRECAUTIONS A This installation manual is intended for professionally competent personnel only The installation the electrical connections and the settings must be completed in conformity with good workmanship and with the laws in force Read the instructions carefully before beginning to install the product Incorrect installation may be a source of danger Packaging materials plastics polystyrene etc must not be allowed to litter the environment and must be kept out of the reach of children for whom they may be a source of danger Before beginning the installation check that the product is in perfec
3. 400 V triphas 50 60 Hz ADSOFDUONL ERI Rein a 6 Alimentation commandes auxiliaire 24V Puissance moteur 0 6 KW Degr de protection tableau de commande IP 55 Temp rature de fonctionnement 5 50 C Rif Description 12 Couvercle colonne 13 Motor ducteur K22 14 Dispositif de manoeuvre manuelle 15 Tige pour man uvre manuelle 16 Tableau lectronique 17 Photocellule LAB4 18 Photocellule 5FB 19 Toile en polyester 20 Fen tre en transparent 21 Bandes verticales de renfort 22 Bord inf rieur avec lest en sable TABLEAU LECTRONIQUE 47E INVERSEUR Tension d alimentation 230 V monophas 50 60 Hz Absorption EE 16 Alimentation commandes auxiliaire 24V Puissance moteur 0 6 KW Degr de protection tableau de commande IP 55 Temp rature de fonctionnement 5 50 C A Dimensionner correctement la section des conducteurs de ligne r f rant l absorption indiqu e en tenant compte de la longueur et de la mise en uvre des c bles 3 ODT833 2015 05 27 3 INSTALLATION M CANIQUE Voir dessins relatifs l installation m canique aux pages 22 23 feuille centrale d tacher 3 1 V rificati
4. Adjust the curtain adjustment moving the position of the guide support The movement must be symmetrical on the two supports Verify the good geometry after the final adjustment The right adjustment has the polizene guides rest to the steel angle supports but with the springs kept in balance Lubricate the guides by vaseline spray spare code 5VSGP Wurth 0893060 ODT833 2015 05 27 38 7 TROUBLESHOOTING DANGER When working with electrical or electronic controls make sure that the power source has been locked out and tagged according to approved local electrical codes The following instructions are intended only for qualified personnel authorized to operate under the owners responsibility Safety rules and local codes must be applied also when our instructions are not specifying it in each single operation For repair or replacement only Entrematic Group AB original spare parts must be used COMMAND TROUBLE VERIFY Any command in all the The curtain and motor do Mains power failure or fuses F1 F2 F3 curtain position not move The stop is activated led Stop of the keyboard ON The motor is connected to wrong terminals and or Dip switch is in wrong position see page 8 The opening and closing C limit switches are activated led 11 and 12 ON Motor with thermal sw
5. 400 ODT833 2015 05 27 48 SIGNALS AND SETTING Setting automatic closing time From 0 to 30 5 Note after the activation of the stop command once contact 1 9 has closed again the automatic closing is only activated after a total partial or step by step opening command Motor partial opening adjustment From 0 to 30 s Dip switch Description OFF Ditec Smart Reset Dip switches setting Control 1 3 function Step by Step Opening Restore automatic closing time Do not use 100 Disabled during Enabled for both opening opening and closing Preflashing set at 3 s Application type Do not use Rapid door Dynamic brake Do not use Enable Double speed Disabled Do not use With the automation blocked if the With the automation blocked if Reversal safety switch function activate the opening operation operation is impossible Electric brake Do not use Normal POWER 24 V power supply Indicates the STOP operation activated by pushbutton panel PT4 if present the AUTOTEST device is installed this indicates a safety Indicates that at least one of the safety test failure terminal 41 contacts is open 6 8 9 On power on the LED flashes to indicate the number of operations performed each rapid flash 10000 operations each slow flash 100000 operations Activated at every command and adjustment to the dip switch
6. Check the fixing of the motor to the relevant support Check the limit switches functioning and the good alignment with the cams Check the brake disc wearing If necessary replace the disc Main Shaft Check the good bearing supports fixing Lubricate the support of the bearings by suitable grease inlet 8 1 Maintenance Plan The table below shows the recommended interval in months when to replace parts during preventive maintenance Cycles hour operation lt 10 lt 30 gt 30 Low Traffic Medium Traffic High Traffic Environment Months Months Months Limit switch group 6DODGF 36 24 12 12 Limit switch 5M 48 36 24 24 Brake disc 22337 36 24 12 12 Upper polizene guide 28106 36 24 12 12 36 24 12 12 Guide compensation spring 28125 Abusive Part Part number Lens group and for SLEC 6GLSLEC 1 Dirty or dusty environment operating temperature near to 0 C or over 35 C wind pressure within 20 of maximum limit Date Cyclecounter Signature Date Cycle counter Signature ODT833 2015 05 27 42 APPLICATIONS Use 4 minimum 5 years of working life with 300 cycles a day Applications INTENSE for industrial and commercial access with intense use Service class running times and the number of consecutive cycles are to be taken as merely indicative having been statistically determined under aver
7. DE 3382 09 The manufacturing process ensures the compliance of the equipment with the technical file The manufacturing process is regularly accessed by 3rd party Compilation of technical file Marco Pietro Zini E mail marco zini entrematic com Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Place Date Signature Position Landskrona 2013 07 01 Marco Pietro Zini President Entrance Automation Ye fer 43 ODT833 2015 05 27 0DT833 2015 05 27 Entrematic Group AB Lodjursgatan 10 5 261 44 Landskrona Sweden www ditecentrematic com ENTREMATIC
8. SLEC Encodeur 14 6 2 R glage de la tension de la toile 14 7 RECHERCHE DES PANNES one onde C Pa dux EEN 15 8 PLAN D ENTRETIEN irri stg alari o RR 16 1 CONSIGNES G N RALES DE S CURIT A Cette notice d installation est destin e exclusivement aux professionnel qualifi s L installation le raccordement lectrique et les r glages doivent tre effectu e selon les r gl s de Bonne Techniques er respecter la r glementation en vigueur Lire attentivement les instructions avant de proc der l installation du produit Une installation erron e peut tre source de danger Les mat riaux de l emballage plastique polystyr ne etc ne doivent pas tre abandonn es dans la nature et ne doivent pas tre laiss s la port e des enfants car ils sont une source potentielle de danger Avant de proc der l installation v rifier l int grit du produit Ne pas installer le produit proximit de mati res explosives la pr sence de gaz ou de vapeurs inflammables repr sente un grave danger pour la s curit Avant d installer le automatismes apporter toutes le modifications structurelles relatives la r alisation des distances de s curit et la protection ou s gr gation de toutes les zones d crasement de cisaillement d entra nement de danger en g n ral V rifier que la structure exi
9. Contr ler l usure du disque du frein Le cas ch ant remplacer le disque Arbre d enroulement toile Contr ler la fixation des supports des roulements Graisser les supports des roulements 8 1 Plan d entretien Le tableau suivant reporte les intervalles recommand s en mois de fonctionnement pour le remplacement des composants pendant l entretien pr ventif Cycles heure Environnement oussi reux Bas Trafic Moyen Trafic Haut Trafic 1 Mois Mois Mois Groupe but e 6DODGF 36 24 12 12 But e microcontact 5M 48 36 24 24 Disque frein 22337 Rail en polyz ne sup rieur 28106 Rail en polyz ne inf rieur V8144BP48 Ressort de compensation des rails 28125 Groupe de Lens et espaceur SLEC G6GLSLEC Description Code 1 Environnement sale et poussi reux temp rature de service proche de 0 C ou sup rieure a 35 C pression du vent dans les 20 au dessus de la limite maximale pr vue REINTRODUCTION DE LA TOILE Approcher la partie sup rieure des rails 1 en faisant levier depuis l ext rieur Introduire chaque l ment de retenue de la toile L dans le rail correspondant si n cessaire pour faciliter l op ration enlever d abord la vis d amortissement K D rouler la toile de mani re ce que le bord inf rieur se trouve un demi m tre sous l ouverture de rentr e de la toile ODT833 2015 05 27 16 ET LIVR
10. RISTIQUES DE L UTILISATION Classe de service 4 minimum de 5 ans d utilisation 300 cycles par jour Usage INTENSIF pour des entr es de type industriel et commercial usage intensif e La classe de service les temps d utilisation et le nombre de cycles cons cutifs sont donn s titre indicatif lls ont t statistiquement relev s dans des conditions d utilisation moyenne et peuvent varier d une application l autre Ils se r f rent une p riode au cours de laquelle le produit fonctionne sans exiger un entretien extraordinaire particulier Chaque entr e automatique pr sente des l ments variables comme les frottements les quilibrages et les conditions ambiantes qui peuvent modifier sensiblement la dur e et la qualit du fonctionnement de l entr e automatique ou d une partie de ses composants parmi lesquels les automatismes ll est la charge de l installateur d adopter des coefficients de s curit adapt s l installation sp cifique D CLARATION DE CONFORMIT Le fabricant soussign Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Su de d clare sous sa responsabilit que le produit SMART RESET Porte rapide enroulement non contrebalanc e caract ris par les niveaux de performance report s dans la D claration de Performance et sur l tiquette du produit et motorisation lectrique comme indiqu dans le manuel d installation qui l accompagne est conforme aux direc
11. turn the C camuntil the relative micro switch is triggered 4 Carry out the same procedure for the opening limit switch bring the curtain to the open door position and adjust cam A 5 When LAB4 photocells are present adjust the bypass limit switch cam so the microswitch is engaged at 200mm from the ground 6 Activate the automation to check the calibration and if necessary make a further adjustment 200 1 33 ODT833 2015 05 27 5 2 47 INVERTER ELECTRONIC CONTROL INPUTS Dee Automatic closing Permanently closing the contact enables automatic closing Opening The closure ofthe contact activates an opening operation Closing The closing manoeuvre starts when the contact is closed Reversal safety Opening the safety contact triggers a reversal of the movement reopening device during a closing operation Reversal safety Opening the safety contact triggers a reversal of the movement reopening device during a closing operation Stop Opening the safety contact stops the current operation Non pulse Permanently opening the safety contact enables the operation by non command pulse command In this state the opening 1 3 1 20 and closing 1 4 controls function only if held in the pressed position and the automation stops when the controls are relea
12. Stop Opening the safety contact stops the current operation Non pulse command Permanently opening the safety contact enables the operation by non pulse command In this state the opening 1 3 1 20 and closing 1 4 controls function only if held in the pressed position and the automation stops when the controls are released All safety switches the step by step control and the automatic closing function are disabled Partial opening The closing of the contact activates a partial opening operation of the duration set with the RP trimmer Once the automation stops the partial opening control performs the opposite operation to the one performed before stoppage Closure limit switch The opening of the limit switch contact stops the closure operation Opening limit switch The opening of the limit switch contact stops the opening operation limit switch photocell By pass photocell Operation by non pulse command Operation by pulse command T OUTPUTS ve Beso CS Accessories power supply 24V 0 5A Power supply output for external accessories including automation status lamp 24 V 1 50 W Flashing light LAMPH 2 A Activated during opening and closing operations 200V 0 2A Output activated during the door running Three phase motor 400 V 4A Note if the direction of rotation of the motor is incorrect for the desired direction of movement swap th
13. and jumper Indicates that the 0 11 limit switch contact is open Indicates that the 0 12 limit switch contact is open Indicates that the 0 17 limit switch contact is open By pass photocell Starts opening operation The green LED on indicates the presence of the 24 V power supply A Starts the partial opening operation the red LED on indicates that the STOP has been activated SES EES SEH the flashing red LED indicates that the safety devices have been activated v Starts the closing operation 0DT833 2015 05 27 32 ELO7L 10000000000000 RP TC ON jala KENA OTT AAA 17 4 12 11 0 O0 O0 1 1 2 3 4 6 8 9 2041 i v Dimension F1 F2 F3 8A 500V 10 3 x 38 Three phase line F4 3 15A 230V 5x20 Transformer F5 2 5A 500V 5x30 Dynamic brake Brake ADJUSTMENT LIMIT SWITCH 1 Activate the door by pressing the appropriate buttons and check it moves in the correct direction and If necessary reverse the movement direction by modifying the phase sequence U W Carry the curtain in the closed position By means of a screwdriver
14. freinage RF 230 50 W 1000 32w CNT La r sistance est activ e pendant chaque man uvre lectrofrein du moteur La sortie est activ e sur toute la dur e du mouvement aussi bien ouverture qu en fermeture 200 V 0 2A 230 V 6A Moteur triphas ODT833 2015 05 27 10 47 A Couper toujours le pontet J2 sur porte Ditec Smart Reset A 22 Marron F C Ralentissement 17 16 Blanc F C Ouverture E E Noire LT 4 F C Fermeture Bleu 0 0 stop Jaune Vert H m Im O O 13 gt n 2 OFFL1 2 3 4 m 15 14 OM SI ai i It H H V Bleu 230 V Noire 7979 Marron 1 9 Fermer Blanc Fonctionnement par commande impulsions Rose Blanc Noire Vert Bleu 8457 Gris Rouge Jaune Orange Bleu Blanc Marron Marron Rouge 7825A 01 8 1 I I 110 ME za zOm Rouge Bleu Jaune Ver
15. rideau de toute d t rioration Aligner les t tes lat rales C et D au fil ext rieur des montants Fixer et s curiser les t tes lat rales l aide des trous E Dimension des chevilles M8 A Utiliser tous les logements de fixation pr vus pour fixer les plaques lat rales au moyen de 8 vis Poids indicatif par m tre 40 kg m environ caisson et carter cache rouleau en cas de portes avec PL gt 4000 il est conseill de fixer la couverture de la traverse au centre afin d viter toute flexion inesth tique de la charpente 3 4 Installation du motor ducteur K22 fig 4 Man uvre manuelle si pr vue ins rer le dispositif en suivant les instructions fig 4 A le microcontact de s curit en suivant le sch ma correspondant et en v rifier le fonctionnement le microcontact doit inhiber la rotation du moteur l enclenchement de la man uvre manuelle Ins rer la clavette dans le si ge de l arbre d enroulement fig 5 Ins rer le motor ducteur sur l arbre Fixer le motor ducteur sur la t te l aide de la patte Fixer le moteur l arbre l aide de la vis J M8 x 55 fournie 3 5 Installation du dispositif de s curit SLEC Encodeur lin aire Le dispositif SLEC doit tre fix sur le rail de coulissement de la porte souple sur le gauche comme l illustre la fig 6 et raccorder comme indiqu au paragraphe 5 3 6 Positionnement de la toile Rapprocher la pa
16. 27 6 22 Marron Sto Marron Noire Jaune Vert us 854 By pass photocellule F C Ouverture F C Fermeture e L ELO7L 0000000000000 Rouge Blue Jaune Vert Rose Blanc Marron Gris 0 1 941FC OUT m PWR _SLEC Marron 7979 Noire Bleu Blanc Rose Rouge Marron 8457 Brus Gris Jaune Vert RP TC SO BEI IN SA POWER ollo NIO 17 14 12110 0 0 11 234689 1 9 Fermer Fonctionnement par commande impulsions Noire Rouge Bleu Orange Blanc Marron 7825A 01 016 p ER 335 za 2 O 8132 8132 A 1 o Noire Bleu Rouge i l Orange Bleu F Bleu Noire Marron 7978 Powe
17. Closing Safety Cycles counter Opening limit switch 4 Starts the opening operation The green LED on indicates the presence of the 24 V power supply A Starts the partial opening operation the red LED on indicates that the STOP has been activated SES EES SEH the flashing red LED indicates that the safety devices have been activated v Starts the closing operation ODT833 2015 05 27 36 Q W GND Circuit ADJUSTMENT LIMIT SWITCH 1 Set the deceleration ramps to zero 5 6 2 Calibrate the limit switch on the gearmotor so the door stops approximately 200 300mm from the closure point 3 Calibrate the opening limit switch A at the opening point 4 Calibrate slowdown limit switch B in such a way that it engages at approximately 34 of the opening stroke 5 Calibrate the opening speeds using trimmer T3 and closure T4 6 Calibrate the opening T5 and closure T6 trimmers of the deceleration ramps in such a way as to cause stopping in the actual door open and door closed positions TROUBLESHOOTING COMMAND TROUBLE VERIFY Every command in every The curtain and the motors Control unit test was failed curtai
18. Ditec ENTREMATIC 0DT833 Ditec Smart Reset rev 2015 05 27 Manuel installation entretien utilisation FR Instructions originales Installation manual maintenance use EN Original instructions www ditecentrematic com d SOMMAIRE DES ARGUMENTS Ch Argument EE 1 AN CONSIGNES G N RALES DE S CURIT 2 2 CARACT RISTIQUES TECHNIQUES 3 3 INSTALLATION M CANIQUE 3 1 V rifications de la baie de PASSAGE 4 3 2 Fixation des montants verticaux uuu uuu u uuu luan aqasusbusqqaqassaya danskara ba li kinat ada sas d ula 4 3 3 Installation de l arbre d enroulement ss 4 3 4 Installation du motor ducteur K22 sss ennemis 4 3 5 Installation du dispositif de s curit SLEC Encodeur lin aire 4 3 6 Positionnement de la u uuu uu uu ttn a alk jas al K lala 4 3 7 Installation des photocellule si pr vues 4 4 BRANCHEMENTS LECTRIQUES 4 1 Tableau lectriq Je esse 5 4 2 du tableau lectrique moteur s curit s 5 4 3 Photocellule de s curit 5 5 TABLEAU LECTRONIQUE GN Kee ET 6 5 2 47E inverseur raccordements iaaiiiaaiaaiannaaat sanna an E KAKAK KK KAKAK UNN KAKAK UK KAKAK KAK AKUN K A 10 6 R GLAGES ET MISE EN MARCHE 6 1 R glage du dispositif de s curit
19. ER A L UTILISATEUR INSTRUCTIONS D UTILISATION ET D ENTRETIEN gt OA CONSIGNES G N RALES DE S CURIT Le pr sent manuel fait partie int grante et essentielle du produit et doit tre remis l utilisateur II faut conserver le pr sent document et le transmettre aux ventuels utilisateurs successifs de l quipement L automatisme en objet est une porte mouvement vertical destiner l usage pour lequel elle a t express ment con ue Tout autre usage est consid r impropre et donc dangereux Entrematic Group AB d cline toute responsabilit pour les dommages d rivant d un usage impropre erron ou irraisonnable PR CAUTIONS D UTILISATION Ne pas entrer dans le rayon d action de la porte lorsqu elle est en mouvement En cas de panne ou de dysfonctionnement couper l interrupteur g n ral Les op rations d entretien de r glage et de r paration doivent uniquement tre ex cut es par un personnel form et autoris Chaque automatisme est accompagn d un Manuel d installation et d entretien dans lequel est entre autre report le plan d entretien p riodique et ou il est recommand en particulier de v rifier tous les dispositifs de s curit BOUTONS POUSSOIRS Ouverture totale ouvre enti rement la porte Le r glage de la course est r alis l aide d un micro interrup teur de fin de course Ouverture partielle ouvre la porte jusqu au point indiqu l aide d
20. O 15 14 Blue Black 7979 Brown White 1 9 To close Operation by pulse command Pink White Black Green Blue Gray Red 8457 Yellow Orange Blue White Brown Brown Red 7825A po 0 1 0 1 8 1 Blue Black Orange Blue ST ST PWR SA SLEC q 7978 d 35 ODT833 2015 05 27 SIGNALS AND SETTING 47 Setting automatic closing time From 0 to 30 5 Partial opening adjustment From 0 to 10 5 Adjust opening speed Adjust closing speed Adjust deceleration in opening Adjust deceleration in closing It define the exact closing point ETTE Description Enable adjustment through Disabled Enabled trimmer Preflashing opening Disabled Enabled Future Use Do not use Do not use Future Use Do not use Do not use Brake power supply 200 Vcc Brake lt Automatic closing Slowing down limit switch Opening Closing limit switch Closing Flashing lamp Stop Run OK Partial opening Fault Safety edge Autotest Stop push button Brake
21. age operating conditions and cannot therefore be applied to each individual case Reference is to the period when the product functions without the need for any extraordinary maintenance Independent variables such as friction balancing and environmental factors may substantially alter the lifespan or performance characteristics of the automatic access parts thereof including the automatic systems It is the responsibility of the installer to adopt suitable safety measures for each single installation DECLARATION OF CONFORMITY We Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden declare under our sole responsibility that the type of equipment with name description SMART PRESET Roll up high speed door With performance levels as declared in the accompanying Declaration of Performance and the product label and electrical drive unit as identified in the log book provided with it is in compliance with the following directives 2006 42 Machinery Directive MD 2004 108 EC ElectroMagnetic Compatibility Directive EMCD Harmonized European standards which have been applied EN 13241 1 EN 61000 6 2 EN 61000 6 3 EN 60335 1 EN 60204 1 Other standards or technical specifications which have been applied EN 60335 2 103 EC type examination or certificate issued by a notified or competent body for full address please contact Entrematic Group AB concerning the eguipment CSI Spa Reg N 0497 Certificate Nr
22. de fermeture C actif voyant 11 allum Commande d ouverture toujours activ e ou en court circuit voyant IN toujours allum Autotest s curit s chou voyant Arr t sur boitier de commande teint et voyant SA clignotant Activation de l Arr t Le moteur ne s arr te pas Commande d arr t d faillante ou mal branch e voyant Arr t pendant une manceuvre sur boitier de commande teint et voyant SA non clignotant Le moteur s arr te Frein moteur us ou en panne retard Activation d une s curit Le mouvement de la porte Dispositif de s curit d arr t en panne ou mal branch pendant la fermeture ne s inverse pas voyant Arr t sur le boitier de commande ne clignote pas al voyant SA ne s allume Le mouvement Entr e 17 ferm e voyant 17 teint porte ne s invertit pas Came mal r gl e LED 17 teinte ou allum e dans la ou S invertit seulement mauvaise position surunepartie dela course Fermeture automatique La porte ne se ferme pas Activation de la fermeture automatique non ex cut e active avec toile ouverte automatiguementapresle correctement raccordement 1 2 temps r gl par TC Commande d ouverture toujours activ e ou en court circuit voyant IN toujours allum Autotest s curit s chou voyant Arr t sur bo tier de commande teint et voyant SA clignotant Pendant une man uvre La toile ne s arr te pas sur Contact de fin de course
23. dynamique Frein R GLAGES FIN DE COURSE 1 Actionnerla porte en appuyant sur les boutons poussoirs correspondants et v rifier le sens du mouvement et si n cessaire inverser le sens du mouvement en modifiant la s quence des phases U W Placer la toile en position de fermeture Porter la toile en position de porte ferm e et l aide d un tournevis tourner la came jusqu ce que le micro interrupteur soit engag 4 Intervenir de la m me mani re pour le fin de course d ouverture porter la toile en position de porte ouverte et r gler la came A 5 de photocellule LAB4 r gler le fin de course de d rivation came de mani re ce que le micro interrupteur soit engag 200 mm sol 6 V rifier le tarage en fonctionnement r el de l automatisme et si B n cessaire effectuer un tarage fin 1200 mm 1 9 ODT833 2015 05 27 5 2 TABLEAU LECTRONIQUE 47E INVERSEUR RACCORDEMENTS ENTR ES commande Fonton Die Fermeture automatique La fermeture permanente du contact habilite la fermeture automatique Ouverture La fermeture du contact active la man uvre d ouverture Fermeture La fermeture du contact active la man uvre de fermeture S curit d inversion L ouverture du contact de s curit entra ne l inversion du mouvement r ouverture lo
24. e U W phases ODT833 2015 05 27 30 22 Brown Stop Brown Black Yellow Green By pass fotocellule LCE Opening limit switch _4 Closing limit switch ELO7L 0000000000000 o E White ob oo RP B Em E CH H 11 12 17 IN SA POWER I N 74 100011234689 N N White s 7979 Black Blue White Pink Red Brown 8457 Sieg Yellow Green Black R 1 9 To close ue Orange Operation by pulse White command Brown 7825A N x d E T 8132 8132 0 1 0161 0 1 061 Ill 5 EE iss mm m On g LL N LZ 0 1 9 41 FC FA OUT x 9 g Sg 8853 3 385 ma mm OX ama mmm PWR SLEC 7978 31
25. eans of brackets or anchor plugs In the case of insufficient or dubious solidity it is necessary to create an adequate self supporting metal structure 3 2 Fitting the uprights fig 2 Put the uprights in plumb and secure them in correspondence with the points indicated A Use M8 anchor plugs Drill on the middle axis of the oval slot A to allow the lateral tensioning of the curtain at the end of the fitting Check the perpendicularity of the assembly by measuring the diagonals 3 3 Installation of the rolling shaft fig 3 Trace the position of the crosspiece fastening holes using the relevant templates B Carefully hoist the crosspiece with a lift truck or other hoisting means making sure it cannot fall during the operation Protect the curtain from any possible damage Align the side heads and D with the outer edge of the uprights Fasten the side heads firmly by means of the holes E using M8 anchor plugs A Use all the fixing outfitted slots secure the side plates by 8 screws Indicative weight of the transom about 40 kg m roller housing and casing for doors with PL gt 4000 you are advised to fasten the crosspiece cover in the centre to avoid any anti aesthetic bending of the structure 3 4 Gearmotor installation K22 fig 4 For manual operation if foreseen insert the device following the indications fig 4 A Connect the micro contact by observing the relevant diagram and check it function
26. ed device during closing not reversed Stop on the keyboard OFF and led SA never flashing The door movement does Input 17 closed to 0 led 17 OFF not reverse or reverses Cam B incorrectly P 17 off or on in the wrong foronlyapartofits stroke position Door open with automatic The door does not close The automatic closure enable signal has not been carried out closure activated automaticallyafterclosing properly connection 1 2 time TC Opening command always activated led IN always ON Self test of the safety device failed led Stop on the keyboard OFF and led SA flashing During operation The curtain doesn t stop The limit switch contact is short circuited led 11 or led 12 at the limitswitch always OFF A mechanical fault in the limit switch led 11 or led 12 always OFF The motor brake worn out or faulty or brake led 11 or led 12 always OFF The curtain doesn t stop Dip switch 5 in OFF regularly atthe limitswitch Fuse F5 fault NB for inverter control unit 47E see also at page 37 39 ODT833 2015 05 27 8 MAINTENANCE CARRIED OUT EVERY 6 MONTHS Regular inspections should be made according to national regulations and product documentation by a Entrematic Group AB trained and qualified technician The number of service occasions should be in accordance with national requirements and with the product documentation Safety Devices Check the correct operation of the safety dev
27. en court circuit voyant 11 ou voyant 12 le fin de course toujours teints e Panne m canique du fin de course voyant 11 ou voyant 12 toujours teints Usure ou panne du frein voyant 11 ou voyant 12 allum s La toile ne s arr te pas Commutateur 5 sur OFF r guli rement sur le fin de Fusible F5 interrompu course N B pour le diagnostic sp cifique du tableau inverseur 47E voir aussi page 13 15 007833 2015 05 27 8 ENTRETIEN TOUS LES 6 MOIS Des contr les r guliers doivent tre effectu s par des techniciens qualifi s et sp cialement form s par Entrematic Group AB conform ment aux r glementations nationales en vigueur et la documentation du produit La fr quence des interventions d entretien doit r pondre aux r glementations nationales en vigueur et la documentation du produit Dispositifs de s curit V rifier le fonctionnement correct du dispositif SLEC Encodeur lin aire V rifier le fonctionnement correct des photocellule de s curit Rails lat raux V rifier l usure des rails lat raux Graisser les rails avec de vaseline spray code pi ce de rechange 5VSGP Wurth article 0893060 Fixation Montage Serrer les vis d accouplement des montants verticaux la traverse sup rieure V rifier l ancrage de la porte la baie Motorisation Contr ler la fixation correcte du moteur Contr ler le fonctionnement des fins de course et l alignement correct des cames
28. ice Linear Encoder SLEC Check the correct operation of the safety photocells Side guides Check the guides wearing and the relevant curtain sliding Lubricate the guides by vaseline spray spare part code 5VSGP Wurth art 0893060 Installation Fitting Tighten the fitting screws of the uprights with the crosspiece Check the anchoring of the door to the door frame Motor Check the fixing of the motor to the relevant support Check the limit switches functioning and the good alignment with the cams Check the brake disc wearing If necessary replace the disc Main Shaft Check the good bearing supports fixing Lubricate the support of the bearings by suitable grease inlet 8 1 Maintenance Plan The table below shows the recommended interval in months when to replace parts during preventive maintenance Cycles hour operation 10 30 230 Low Traffic Medium Traffic High Traffic Months Months Months Abusive Environment 1 Part Part number Limit switch group 6DODGF 36 24 12 12 Limit switch 5M 48 36 24 24 Brake disc 22337 Upper polizene guide 28106 Lower polizene guide V8144BP48 Guide compensation spring 28125 Lens group and spacer for SLEC 6GLSLEC 1 Dirty or dusty environment operating temperature near to 0 C or over 35 C wind pressure within 20 of maximum limit REINSERT THE CURTAIN IU Close the upper part of the p
29. ions de la commande sans impulsions Dans cette condition les commandes d ouverture 1 3 1 20 et de fermeture 1 4 ne fonctionnement que si elles sont maintenues enfonc es leur rel chement l automatisme s arr te Les ventuelles s curit s la commande pas pas et la fermeture automatique sont d shabilit Ouverture partielle La fermeture du contact active une man uvre d ouverture partielle sur une dur e impos e l aide du potentiom tre Lorsque l automatisme est l arr t la commande d ouverture partielle ex cute la man uvre oppos e celle qui a pr c d l arr t Le fin de course se ferme L ouverture du contact du fin de course arr te le mouvement de fermeture Le fin de course s ouvre L ouverture du contact du fin de course arr te le mouvement d ouverture Fin de course photocellule By pass photocellule Fonctionnement par commande sans impulsions Fonctionnement par commande impulsions T SORTIE Alimentation des accessoires 24V 0 5A Sortie permettant d alimenter les accessoires externes y compris les lampes d tat de l automatisme 24 V 50 W Clignotante LAMPH 2 A Elle s active lors des man uvres d ouverture et de fermeture 200V 0 2A Sortie active pendant le mouvement de la porte Moteur triphas 400 V 4A N B si la rotation du moteur ne correspond pas au sens de marche inverser les phases U W 0DT833 2015 05
30. itch activated led 11 and 12 ON Safety switch of the manual rod activated led 11 and 12 ON One of the power devices is faulty control unit motor motor cabling etc The motor turns in the Reverse the two phases of the mains power supply opposite direction Opening command at The motor does not move The opening command is not correctly connected or it is faulty closed curtain led IN does not switch ON Safety device activated led Stop flashing on the keyboard and led SA fixed ON with bridge SO closed The opening limit switch A is activated Closure command always activated led IN always ON Closure command at The motor does not move The closing command is not correctly connected or is faulty opened curtain led IN does not switch ON Safety device activated led Stop flashing on the keyboard and led SA fixed ON The closing limit switch C is activated led 11 fixed in ON Opening command always activated led IN always ON Self test of the safety device failed led Stop on the keyboard OFF and led SA flashing Activation of the stop The motor does not stop The stop command is faulty or is not correctly connected led during a door cycle stop on the keyboard never in ON and led SA not flashing The motor stops with The motor brake worn out or faulty delay Activation of one safety The motor movement is The safety device is faulty or is not correctly connected l
31. lastic guides I by pushing on the outer side Insert each tooth side edge L of the curtain in the relevant guide if necessary to make easier the operation remove the higher screw K Roll down the curtain so the bottom edge is 0 5m beneath the curtain inlet slot ODT833 2015 05 27 40 DETACH AND DELIVER TO THE CUSTOMER USE INSTRUCTIONS gt ER GENERAL SAFETY PRECAUTIONS This user handbook is an integral and essential part of the product and must be delivered to the users Keep this document and pass it on to any future users This automation is a vertical roll door it must be used for the specific purpose for which it was designed other use is to be considered inappropriate and so dangerous Entrematic Group AB declines all responsibility for damage caused by improper incorrect or unreasonable use USE PRECAUTIONS Do not enter the door action area while the door is moving In the event of a fault or malfunctioning turn off the main switch The operations of maintenance adjustment and repair must be carried out by skilled and authorised staff Each automation has its own Installation and Maintenance handbook reporting the periodical maintenance plan Please take care to check all the safety devices BUTTONS Full opening the door opens completely The stroke can be fixed via the end stop microswitch Partial opening the door opens partially to a point time regulated by the RP
32. lconque dans d marrent pas ARRET STOP activ voyant Arr t sur bo tier de n importe quelle commande allum fixe position de la toile Moteur branch aux mauvaises bornes et ou Dip switch dans la mauvaise position voir page 8 Fin de course d ouverture A et fin de course de fermeture C actifs en m me temps voyants 11 et 12 allum s Moteur en protection thermique voyants 11 et 12 allum s Micro interrupteur de s curit de la manceuvre manuelle actif voyants 11 et 12 allum s Lun des dispositifs de puissance est en panne tableau lectronique moteur c ble de raccordement moteur Le moteur tourne dans le Inverser la position de deux phases de la ligne d alimentation sens de rotation inverse Commande d ouverture Le moteur ne d marre pas Commande d ouverture mal branch e ou d faillante le voyant avec toile ferm e IN ne s allume pas l activation de la commande S curit activ e voyant du bouton Arr t clignotant et voyant SA allum fixe avec pontet SO ferm Fin de course d ouverture A actif voyant 12 allum Commande de fermeture toujours activ e ou en court circuit voyant IN toujours allum Commande de fermeture Le moteur ne d marre pas Commande de fermeture mal branch e ou d faillante le avec toile ouverte voyant IN ne s allume pas l activation de la commande S curit activ e voyant du bouton Arr t clignotant et voyant SA allum fixe Fin de course
33. lectroniques lectroniques 48 49 51 47E 1234 6 2 R glage de la tension de la toile fig 13 Fermer la porte R gler la tension de la toile en agissant sur la position des supports des rail Le d placement doit tre sym trique sur les deux supports V rifier la g om trie correcte du montage la fin du r glage Le r glage optimal se v rifie l aide de rails en polyz ne en appui sur les supports en acier mais avec les ressorts quilibre de compression Graisser les rails avec de vaseline spray code pi ce de rechange 5VSGP Wurth article 0893060 ODT833 2015 05 27 14 7 RECHERCHE DES PANNES DANGER Avant d effectuer toute op ration ou travail l int rieur des quipements lectroniques v rifier s ils ont t mis hors tension Les instructions suivantes s adressent exclusivement un personnel qualifi et autoris Se conformer toujours aux lois et aux normes sp cifiques m me si cette prescription n est pas express ment indiqu e Pour les r parations ou les remplacements utiliser toujours et exclusivement des pi ces de rechange originales Entrematic Group AB COMMANDE DYSFONCTIONNEMENT V RIFICATION Une commande La toile et le moteur Alimentation de r seau ou fusibles F1 F2 F3 que
34. mm A935C PH gt 4000mm A935L Marron gt Marron gt Bleu Bleu Noire A Dimensionner correctement la section des conducteurs de ligne en se r f rant l absorption indiqu e et en tenant compte de la longueur et de la mise en uvre des c bles 5 ODT833 2015 05 27 48 5 1 TABLEAU LECTRONIQUE 48 RACCORDEMENTS ENTR ES Commande Fonction N O Fermeture automatique La fermeture permanente du contact habilite la fermeture automatique Ouverture Avec le DIP1 sur ON la fermeture du contact active la man uvre d ouverture Pas pas Avecle DIP1 sur OFF la fermeture du contact active une man uvre d ouverture ou de fermeture en s quence ouverture arr t fermeture ouverture N B si la fermeture automatique est habilit e l arr t n est pas permanent se limite la dur e impos e par TC Fermeture La fermeture du contact active la man uvre de fermeture S curit d inversion L ouverture du contact de s curit entra ne l inversion du mouvement r ouverture lors de la phase de fermeture S curit d inversion L ouverture du contact de s curit entra ne l inversion du mouvement r ouverture lors de la phase de fermeture Arr t L ouverture du contact de s curit entra ne l arr t du mouvement Commande sans L ouverture permanente du contact de s curit habilite le fonctionnement impuls
35. n in the door each cable is identified by a special code on an adhesive label 4 3 Safety photocells Wire the device as per the diagram fig 12 Make the connections in the control panel as shown in the diagrams NN ss KK NN 8457 PH lt 4000mm A935C PH 2 4000mm A935L lt r cx Blue Brown lt Correctly size the line conductor cross section by referring to the indicated absorption and taking the length and installation of the cables into account 29 ODT833 2015 05 27 48 5 1 48 ELECTRONIC CONTROL PANEL CONNECTIONS INPUTS Command Den CS Automatic closing Permanently closing the contact enables automatic closing Opening With DIP1 ON the closure of the contact activates an opening operation Step by step With DIP1 OFF the closure of the contact activates an opening or closing operation in the following seguence open stop close open Note if automatic closing is enabled the stop is not permanent but at a time that is set by the TC Closing The closing manoeuvre starts when the contact is closed Reversal safety Opening the safety contact triggers a reversal of the movement reopening device during a closing operation Reversal safety Opening the safety contact triggers a reversal of the movement reopening device during a closing operation
36. n position don t move led 13 green OFF led 14 red ON Opening Command Themotormoveserratically Check if the J2 jumper has been cut brake is not activated or does notreached the set Check that the mains voltage is constant during the operation Lower the opening speed trimmer T3 During the closing The motors doesn t made Adjustment of the closing limit switch C at 300 mm from movement deceleration ramp the floor Adjustment of the deceleration ramp by means the trimmer T6 NB for general diagnostics see also at page 39 37 007833 2015 05 27 6 ADJUSTING AND STARTING 6 1 Adjustment of the Safety Linear Encoder SLEC Power supply on Power supply off Initialization Intervention due to obstacle Normal operating no Test running obstacle Test failed Alarm 9 9 Windproof function Disabled Enabled ON Obstacle detection Enabled only TI after FC closing Disabled control panels limit switch with INVERTER HIGH LOW Scale of sensitivity doors close doors close For 48E For 47E quickly slowly Dip switches Dip switches setting setting 0 Limit switch 17 Limit ON Limit switch common switch common polarity control panels control panels 1234 48 49 51 47 6 2 Tensioning adjustment of the curtain fig 13 Close the door curtain
37. nt clignote pour indiquer le comptage des man uvres ex cut es chaque clignotement rapide 10000 man uvres chaque clignotement lent 100000 man uvres S allume a chaque commande et a chaque modifi cation des commutateurs DIP et des pontets II indique que le contact du fin de course de fermeture 0 11 est ouvert Il indique que le contact du fin de course d ouverture 0 12 est ouvert II indique que le contact du fin de course 0 17 est ouvert By pass photocellule Active la man uvre d ouverture Le voyant vert allum signale la pr sence de l alimentation 24 V Active la man uvre d ouverture partielle Le voyant rouge allum signale l activation de l arr t STOP D SS Le voyant rouge clignotant signale l activation des s curit s v Active la man uvre de fermeture ODT833 2015 05 27 8 ELO7L 10000000000000 RP TC ON jala KENA OTT AAA 17 4 12 11 0 O0 O0 1 1 2 3 4 6 8 9 2041 FUSIBLES i5 valeurs Dimension Sean F1 F2 F3 8A 500V 10 3 x 38 Ligne Triphas e F4 3 15A 230V 5x20 Transformateur F5 2 5A 500V 5x30 Frein
38. oducts only Entrematic Group AB original spare parts must be used The fitter must supply all information corcerning the automatic the manual and emergency operation of the motorised door or gate and must provide the user the device with the operating instructions Optional accessory Safety Confort Safety Top All right reserved All data and specifications have been drawn up and checked with the greatest care The manufacturer cannot however take any responsibility for eventual errors ommisions or incomplete data due to technical or illustrative purposes ODT833 2015 05 27 26 Ref Description Lateral plate of the transom Transom Transom cover Rolling shaft Linear Encoder SLEC Polyzene guide upper section Polyzene guide lower section Fixing plate of the guide Angular vertical post 0 Supporting spring 1 Fixing screw gt COON 0 Q P ON 2 TECHNICAL CHARACTERISTICS CONTROL PANEL TRIPHASE 48E Power supply voltage 400 V triphase 50 60 Hz POWER input 6A Auxiliary control power voltage 24V Moter rating scisco iecit eden tes RE RR kanada 0 6 KW Control board protection class IP 55 Operating temperature 5 50 C Ref Description 12 Column cover 13 Geared motor K22 14 Manual driving device 15 Manual driving rod 16 Electronic boa
39. ons de la baie de passage fig 1 V rifier les dimensions du passage et la correspondance avec les mesures d encombrement de la porte fournie en tenant compte des ventuelles tol rances n cessaires dans le cas d une installation dans l embrasure du passage V rifier que les encombrements ventuels existants n entravent pas le montage de la structure S assurer que les plans d appui sont bien nivel s et ventuellement les ajuster en utilisant des paisseurs appropri es V rifier la consistance de la structure du passage un ancrage s r doit tre garanti grace l utilisation de pattes ou de chevilles En cas de consistance insuffisante ou douteuse il faudra r aliser une structure m tallique autoportante ad quate 3 2 Fixation des montants verticaux fig 2 Mettre les montants verticaux d aplomb et les fixer en correspondance des points indiqu s A Dimension des chevilles M8 Percer sur l axe central du trou oblong A de mani re pouvoir effectuer la tension lat rale de la toile la fin du montage V rifier l orthogonalit du montage en mesurant les diagonales 3 3 Installation de l arbre d enroulement fig 3 Tracer la position des percages de fixation de la traverse l aide des gabarits B correspondants Soulever soigneusement la traverse l aide d un chariot l vateur ou d un autre moyen de levage en s assurant qu elle ne puisse pas tomber pendant la phase de levage et en prot geant le
40. r 400 0DT833 2015 05 27 48 R GLAGES ET SIGNALISATIONS R glage de la dur e de la fermeture automatique De 0 30 5 apr s l activation de la commande d arr t la fermeture du contact 1 9 la fermeture automatique n est habilit e qu apr s une commande d ouverture totale partielle ou R glage de l ouverture partielle du moteur De 0 30 s Mission de en m Ouverture Renouvellement de dur e Ne pas utliser 100 LT eeneg EE 123415 6 Type d application Ne pas utiliser Porte flexible A Frein dynamique en fermeture Ne pas utiliser Habilit Double vitesse D shabilit Ne pas utiliser rt Description Fonctionnement de la s curit Lorsque l automatisme est l arr t si Lorsque l automatisme est l arr t d inversion le contact 41 8 est ouvert on pourra si le contact 41 8 est ouvert toutes activer la manoeuvre d ouverture les man uvres sont interdites lectrofrein Ne pas utiliser Normal En POWER Pr sence de l alimentation 24 V Indique que la fonction d arr t STOP est activ e par le tableau de commande PT4 si mont En cas d utilisation d un dispositif SOFA1 il indique Indique qu au moins un des contacts de s curit l chec du test de s curit borne 41 est ouvert 6 8 9 l allumage le voya
41. raux Graisser les rails avec de vaseline spray code pi ce de rechange 5VSGP Wurth article 0893060 Fixation Montage Serrer les vis d accouplement des montants verticaux la traverse sup rieure V rifier l ancrage de la porte la baie Motorisation Contr ler la fixation correcte du moteur Contr ler le fonctionnement des fins de course et l alignement correct des cames Contr ler l usure du disque du frein Le cas ch ant remplacer le disque Arbre d enroulement toile Contr ler la fixation des supports des roulements Graisser les supports des roulements 8 1 Plan d entretien Le tableau suivant reporte les intervalles recommand s en mois de fonctionnement pour le remplacement des composants pendant l entretien pr ventif Cycles heure Envi t nvironnemen 10 30 gt 30 poussi reux Bas Trafic Moyen Trafic Haut Trafic 1 5 5 5 Groupe but e 6DODGF 36 24 12 12 But e microcontact 5M 48 36 24 24 Disque frein 22337 24 Rail en polyz ne sup rieur 28106 24 Rail en polyz ne inf rieur V8144BP48 Ressort de compensation des rails 28125 Groupe de Lens et espaceur SLEC 6GLSLEC Description Code 1 Environnement sale et poussi reux temp rature de service proche de 0 C ou sup rieure a 35 C pression du vent dans les 20 au dessus de la limite maximale pr vue ODT833 2015 05 27 18 CARACT
42. rd 17 Photocell LABA 18 Photocell 5FB 19 Polyester curtain 20 PVC transparent window 22 Vertical re reinforcing strips 22 Bottom edge with sand ballast CONTROL PANEL INVERTER 47E Power supply voltage 230 V monofase 50 60 Hz Power Input idees daam aa oak 16 A AN Auxiliary control power voltage 24V Motor 0 6 KW Control board protection class IP 55 Operating temperature 5 50 C Correctly size the line conductor cross section by referring to the indicated absorption and taking the length and installation of the cables into account 27 ODT833 2015 05 27 3 MECHANICAL INSTALLATION See the relevant drawings of the mechanical installation at page 22 23 central sheet to be removed 3 1 Checking the opening fig 1 Check the dimensions of the opening and their correspondence to the overall dimensions of the door supplied taking into consideration any necessary tolerances in the case of installation in an archway Check that no existing structures obstruct the assembly of the door Ensure the resting surfaces are level and if necessary adapt them using appropriate shims Check the solidity of the opening secure anchorage must be ensured by m
43. rs de la phase de fermeture S curit d inversion L ouverture du contact de s curit entra ne l inversion du mouvement r ouverture lors de la phase de fermeture Arr t L ouverture du contact de s curit entra ne l arr t du mouvement Commande sans impulsions L ouverture permanente du contact de s curit habilite le fonctionnement de la commande sans impulsions Dans cette condition les commandes d ouverture 1 3 1 20 et de fermeture 1 4 ne fonctionnement que si elles sont maintenues enfonc es leur rel chement l automatisme s arr te Les ventuelles s curit s la commande pas pas et la fermeture automatique sont d shabilit es Ouverture partielle La fermeture du contact active une man uvre d ouverture partielle sur une dur e impos e l aide du potentiom tre RP Le fin de course se ferme L ouverture du contact du fin de course arr te le mouvement de fermeture Fin de course du ralentissement L ouverture du contact du fin de course active le ralentissement en ouverture Le fin de course s ouvre L ouverture du contact du fin de course arr te le mouvement d ouverture SORTIE Alimentation des accessoires 24V 0 5 A Sortie permettant d alimenter les accessoires externes y compris les lampes d tat de l automatisme Clignotante LAMP Elle s active lors des man uvres d ouverture et de fermeture LAMP RF Activation r sistance de
44. rtie sup rieure des rails I en faisant levier par l ext rieur fig 7 Introduire chaque l ment de retenue de la toile L dans le rail correspondant si n cessaire pour faciliter l op ration enlever d abord la vis d amortissement K D rouler la toile de mani re ce que le bord inf rieur se trouve un demi m tre sous l ouverture de rentr e de la toile fig 8 3 6 Installation des photocellule si pr vues fig 9 Fixer les boitiers aux montants verticaux une hauteur maximale de 200 mm du sol Raccorder les photocellules comme indiqu dans la fig 12 ODT833 2015 05 27 4 4 BRANCHEMENTS LECTRIQUES 4 1 Tableau lectrique Ins rer dans le conteneur les c bles avec les borniers d j c bl s et les brancher aux cartes fig 10 Loger les c bles dans le chemin de c bles et brancher les connecteurs pr dispos s sur le moteur fig 11 4 2 Raccordements du tableau lectrique moteur s curit s Sur la figure 12 sont report s les sch mas lectriques des c blages et leur positionnement sur la porte chaque c blage est identifi par un code appos sur une tiquette adh sive 4 3 Photocellule de s curit Ex cuter les raccordements sur la porte comme indiqu sur la fig 12 Ex cuter les raccordements dans le tableau lectronique comme indiqu sur les sch mas NN ss KK NN 8457 PH lt 4000
45. s correctly the micro contact must cut off motor rotation when manual operation is activated Insert key in its slot G on the winding shaft shaft fig 5 Insert the gearmotor on the shaft Fix the gearmotor on the head by means of the bracket H Fix the motor to the shaft by means the screw J M8 x 55 foreseen in the equipment 3 5 Installation of the Safety Linear Encoder SLEC The SLEC must be fixed to the sliding guide of the flexible door on the left side as shown in fig 11 and connected as shown at the paragraph 5 3 6 Positioning the curtain Close the upper part of the plastic guides I by pushing on the outer side fig 6 Insert each tooth side edge L of the curtain in the relevant guide if necessary to make easier the operation remove the higher screw K Roll down the curtain so the bottom edge is 0 5m beneath the curtain inlet slot fig 8 3 7 Installing the photocells when foreseen fig 9 Fix the photocells housing to the uprights at max 200 mm from the floor Connect the photocells as shown in fig 12 ODT833 2015 05 27 28 4 ELECTRIC CONNECTIONS 4 1 Control panel Insert the cables with pre wired terminal boards in the housing and connect them to the cards fig 10 Fit the cables in the conduit and connect the connectors on the motor fig 11 4 2 Connecting the control panel motor security Figure 12 shows the layout of the cables supplied and their positio
46. sed All safety switches the step by step control and the automatic closing function are disabled Partial opening The closing of the contact activates a partial opening operation of the duration set with the RP trimmer Closure limit switch The opening of the limit switch contact stops the closure operation Limit switch The opening of the limit switch contact activates the slowdown in opening slowdown Opening limit switch The opening of the limit switch contact stops the opening operation OUTPUTS ow Dee CS Accessories power supply 24V 0 5A Power supply output for external accessories including automation status lamp Flashing light LAMP 230 V 50 W Activated during opening and closing operations RF Enabling RF brake resistance CNT Resistance is enabled during all operations Electric motor brake 90 ESTO The output is active for the duration of both the opening and closing operation 230 V 6A Three phase motor ODT833 2015 05 27 34 CNT Slowdown limit switch 17 16 Opening limit switch EI EI LA Closing limit switch 1 m m Yellow Green m Brown m m Black m Grey 13 White x gt z 2 OFFL1 23 4
47. stante ait les qualit s requises de robustesse et de stabilit Le dispositifs de s curit photocellule barres palpe uses arr t d urgence etc doivent tre install s en tenant compte des normes et directives en vigueur des crit res de Bonne Technique de l emplacement de l installation de la logique de fonctionnement du syst me et des forces d gag es par la porte ou le portail quip s d automatismes Les dispositifs de s curit doivent prot ger les zones ventuelles d crasement de cisaillement d entrainement et de danger en g n ral de la porte ou du portail automatis s Appliquer la signalisation pr vue par la r glementation en vigueur pour localiser les zones dangereuses Toute installation doit indiquer de fa on visible les donn es d identification de la porte ou du portail automatis s A Avant de proc der au raccordement lectrique s assurer que les donn es de la plaquette signal tique correspondent a celles du r seau d alimentation lectrique Pr voir sur le r seau d alimentation un dispositif de coupure omnipolaire avec une distance d ouverture des contacts gale ou sup rieure 3 mm V rifier qu en amont de l installation lectrique il y ait un interrupteur diff rentiel ainsi qu une protection contre des surchanges de courant ad quate Relier la porte ou le portail automatis s un syst me de mise la terre efficace install conform ment aux normes de s curit en vigueur Le constr
48. t Rose Blanc Marron Gris F ST 0 1 9 41FC FA OUT PWR SA SLEC q 7978 d 11 ODT833 2015 05 27 R GLAGES SIGNALISATIONS 47 R glage de la dur e de la fermeture automatique De 0 30 5 R glage de l ouverture partielle De 0 10 5 R glage de la vitesse d ouverture R glage de la vitesse de fermeture R glage de la d c l ration en ouverture R glage de la d c l ration en fermeture ipswich Description Habilite le r glage par potentiom tre D shabilit Habilit Pr clignotement l ouverture D shabilit Habilit Usage futur Ne pas utiliser Ne pas utiliser Usage futur Ne pas utiliser Ne pas utiliser Alimentation du frein Frein 200 Vcc lt gt Fermeture automatique F C Ralentissement Ouverture F C Fermeture Fermeture Clignotant Arr t Marche RUN OK Ouverture partielle D faut S curit du bord Autotest Bouton poussoir d arr t Frein S curit en fermeture Compteur de man uvres F C Ouverture Active la man uvre d ouverture Le voyant vert allum signale la pr sence de l alimentation 24 V Active la man uvre d ouverture partielle Le voyant rouge allum signale l activation de l arr t STOP desaciive Id anedon arrer Le voyant rouge clignotant signale l activation des s curit s v Acti
49. t condition Do not install the product in explosive areas and atmospheres the presence of flammable gas or fumes represents a serious threat to safety Before installing the door make all the structural modifications necessary in order to create safety clerance and to guard or isolate all the compression shearing trapping and general danger areas Check that the existing structure has the necessary strength and stability The safety devices must protect against compression shearing trapping and general danger areas of the motorized door Display the signs required by law to identify danger areas Each installation must bear a visible indication of the data identifying the motorised door A Before connecting to the mains check that the rating is correct for the destination power requirements A multipolar isolation switch with minimum contact gaps of 3 mm must be included in the mains supply Check that upstream of the electrical installation there is an adequate differential switch and a suitable circuit breaker Ensure that the motorised door has an earth terminal in acwireance with the safety adjustements in force The manufacturer of the door declines all responsability in cases where components which are incompatible with the safe and correct operation of the product only original spare parts must be used or whenever modifications of any nature are made that have not been specifically authorised by the manufacturer For repairs or replacements of pr
50. tion de la toile Commande d ouverture Le moteur a du mal V rifier si le pontet J2 a t coup le frein ne s active pas d marrer ou n atteint V rifier si la tension de secteur reste constante pendant la pas la vitesse r gl e man uvre Abaisser le trmmer de la vitesse en ouverture T3 Pendant la man uvre Le moteur n effectue pas R glage du fin de course de fermeture 300 mm environ de fermeture la rampe de d c l ration sol R glage de la rampe de d c l ration par trimmer T6 N B pour le diagnostic g n ral voir aussi page 15 13 ODT833 2015 05 27 6 R GLAGES 6 1 R glage du dispositif de s curit Encodeur lin aire Tension pr sente Tension absente R glages Intervention pour obstacle Op ration normale Test en cours absence d obstacle Test chou Alarme 9 9 9 Fonction Coupe vent D sactiv e Activ e ON D tection Activ e seulement obstacle apr s fin D sactiv e tableaux de course lectroniques avec de fermeture FC INVERSEUR chelle de HAUTE BASSE Pour 48E Pour 47E portes rapides portes lentes n n sensibilit positionner positionner en fermeture en fermeture les Dip switch de les Dip switch de mani re suivante mani re suivante 0 Commun fin 1 Commun fin TP de course de course ON Polarit fin de HH EN course tableaux tableaux
51. tives suivantes 2006 42 EC Machinery Directive MD 2004 108 EC ElectroMagnetic Compatibility Directive EMCD Normes europ ennes harmonis es appliqu es EN 13241 1 61000 6 2 EN61000 6 3 EN 60335 1 60204 1 Autres normes ou sp cifications techniques appliqu es EN 60335 2 103 L organisme notifi suivant pour l adresse compl te contacter Entrematic Group AB a d livr le Certificat d examen de type relatif au produit en objet CSI Spa Reg N 0497 Certificate Nr DE 3382 09 Le proc d de fabrication assure la conformit du produit au dossier technique Le proc d de fabrication est r guli rement contr l par un tiers Responsable du dossier technique Marco Pietro Zini E mail marco zini entrematic com Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Su de Lieu Date Signature Fonction Landskrona 2013 07 01 Marco Pietro Zini Pr sident Entrance Automation Ye fer 19 007833 2015 05 27 INSTRUCTIONS POUR RESTAURATION TABLIER AVEC ISSUE DE SECOURS 007833 2015 05 27 20 LISTE DES COMPOSANTS Colonne Gauche Colonne Droite Couvercle Gauche Couvercle Droit Arbre d enroulement Moteur K22 Armoire de commande Bo te accessoires 21 ODT833 2015 05 27 DESSINS INSTALLATION M CANIQUE EE Oee 002 PL 380 LT
52. trimmer STOP the door stops immediately Closing the door closes completely The stroke can be fixed via the end stop microswitch OPTIONAL DS MANUAL OPERATION To manually raise the curtain in the event of a power failure or fault raise the curtain to the open door position as shown Do not leave the manual operation rod hanging on the ring during normal door operating Use the special wall mounted fastening clip Installer Entrematic Group AB Ditec Lodjursgatan 10 SE 261 44 Landskrona Sweden ENTREMATIC www ditecentrematic com 41 ODT833 2015 05 27 8 MAINTENANCE CARRIED OUT EVERY 6 MONTHS Regular inspections should be made according to national regulations and product documentation by a Entrematic Group AB trained and qualified technician The number of service occasions should be in accordance with national requirements and with the product documentation Safety Devices Check the correct operation of the safety device Linear Encoder SLEC Check the correct operation of the safety photocells Side guides Check the guides wearing and the relevant curtain sliding Lubricate the guides vaseline spray part code 5VSGP Wurth 0893060 Installation Fitting Tighten the fitting screws of the uprights with the crosspiece Check the anchoring of the door to the door frame Motor
53. u potentiom tre RP STOP provoque l arr t imm diat de la porte Fermeture referme enti rement la porte Le r glage de la course est r alis l aide d un micro interrupteur de fin de course OPTION DS MANCEUVRE MANUELLE Pour lever manuellement la toile en cas de coupure de l alimentation ou de panne lever la toile jusqu la position de porte ouverte comme illustr sur le sch ma Ne pas laisser la tige de manoeuvre manuelle accroch e la bague pendant le fonctionnement normal de la porte Utiliser les clips de fixation murale pr vus cet effet Fermeture Ouverture Installateur Entrematic Group AB Ditec Lodjursgatan 10 SE 261 44 Landskrona Sweden ENTREMATIC www ditecentrematic com 17 ODT833 2015 05 27 8 ENTRETIEN TOUS LES 6 MOIS Des contr les r guliers doivent tre effectu s par des techniciens qualifi s et sp cialement form s par Entrematic Group AB conform ment aux r glementations nationales en vigueur et la documentation du produit La fr quence des interventions d entretien doit r pondre aux r glementations nationales en vigueur et la documentation du produit Dispositifs de s curit V rifier le fonctionnement correct du dispositif SLEC Encodeur lin aire V rifier le fonctionnement correct des photocellule de s curit Rails lat raux V rifier l usure des rails lat
54. ucteur des automatismes d cline toute responsabilit au cas seraientinstall s des composants incompatibles en termes de s curit et de bon fonctionnement ou dans le cas seraient apport es des modifications de quelque nature qu elles soient sans son autorisation sp cifique En cas de r paration ou de remplacement des produits des pi ces de rechange originales Entrematic Group AB Imp rativement tre utilis es L installateur doit fournir tous les renseignements concernant le fonctionnement automatique manuel ou de secours de la porte ou du portail automatis s et remettre la notice d emploi l utilisateur Accessoire en option Safety Confort Safety Top Tous droits r serv s Les informations mentionn es dans ce catalogue ont t contr l es avec la plus grande attention Toutefois nous d clinons toute responsabilit en cas d erreurs omissions ou approximations d pendant d exigences techniques ou graphiques ODT833 2015 05 27 2 of 2 Description T tes lat rales Caisson Couvercle caisson Arbre d enroulement SLEC Encodeur lin aire Rail en polyz ne section sup rieure Rail en polyz ne section inf rieure Support de fixation rail Corni re verticale 0 Ressort de support rail 1 Vis de fixation rail gt ORI 0 Q P ON 2 CARACT RISTIQUES TECHNIQUES TABLEAU LECTRONIQUE TRIPHAS 48E Tension d alimentation
55. ve la man uvre de fermeture ODT833 2015 05 27 12 47 A Couper toujours le pontet J2 sur porte Ditec Smart Reset A i 11 10 9 8 J1 EJ EJ EJ E3 230 V 50 60 Hz FUSIBLES Valeurs Dimension Circuit 12A 500V 10 3 x 38 Ligne Monophas e R GLAGE DES FINS DE COURSE 1 Tarer les rampes de d c l ration z ro T5 T6 2 Tarer le fin de course C sur le motor ducteur de mani re ce que la porte se ferme environ 200 300 mm du point de fermeture 3 Tarer le fin de course d ouverture A au point d ouverture 4 Tarer le fin de course de ralentissement B de mani re ce qu il s engage au environ de la course d ouverture 5 Tarer la vitesse d ouverture l aide du potentiom tre T3 et la vitesse de fermeture T4 6 Tarer les potentiometres des rampes de d c l ration T5 en ouverture et T6 en fermeture de mani re obtenir l arr t sur les positions r elles de porte ouverte et de porte ferm e RECHERCHE DES PANNES COMMANDE DYSFONCTIONNEMENT V RIFICATION Une commande La toile et le moteur ne Test du tableau lectronique chou voyant 13 vert teint et quelconque dans d marrent pas voyant 14 rouge allum n importe quelle posi