1. examen de modelo SK 11 MIOO1 SMUO20 El Directo de Calidad realiza esta declaraci n en nombre del fabricante Sensus GmbH Hannover P sos Sensus GmbH Hannover Telefon 49 0 5102 74 0 Meineckestra e 10 Telefax 49 0 5102 74 3341 D 30880 Laatzen Bankverbindung Deutsche Bank AG Hannover Amtsgericht Hannover HRB 61468 Ust Id Nr DE 115507611 St Nr 27 661 0270 6 Konto 04 44 000 BLZ 250 700 70 Gesch ftsf hrung R diger Guse Klaus Gr bl WWW Sensus com
2. m nima aguas arriba de 0 5 bar debe existir Con una presi n m s baja la conmutaci n de la v lvula no est asegurada 3 Incluido en la entrega 1 Contador de agua 2 juntas 1 manual 4 Informaci n t cnica Refi rase al cat logo t cnico LB1810 http www sensusesaap com 5 Instrucciones de instalaci n 5 1 Consejos de seguridad 5 1 1 Cuando el contador est instalado en la tuber a ste no debe estar sometido a tensiones mec nicas Las bridas de la tuber a deben quedar alineadas con las del contador y la distancia entre bridas debe coincidir con la longitud del cuerpo del contador Los esfuerzos causados por desalineaci n pueden causar que el cuerpo del contador o las bridas se agrieten Cuando la tuber a est bajo presi n esto puede causar inundaci n 5 1 2 El contador no debe estar sujeto a presiones m s altas que la presi n que marca en la placa del contador Una presi n alta puede causar escapes o reventar el cuerpo del contador 5 2 Herramientas de instalaci n Dos llaves inglesas correspondiente al tama o del tornillo utilizado Pueden requerir el levantamiento de dispositivos dependiendo del peso del contador y de las condiciones de la instalaci n 5 3 Instrucciones de instalaci n 5 3 1 MeiTwin seg n su aprobaci n no necesita ning n tramo recto aguas arriba o abajo del contador UODO 5 3 2 El di metro de la tuber a no debe reducirse o incrementarse bruscamente directamente aguas arriba del contado
3. meter 612MTW 612MTW HRI und and 612MTW ER56 Nach oben oder zur Seite Upwards or sideways horizontal horizontal vertikal vertical Nebenz hler By Pass meter Installation instructions MeiTwin with flow straightener MID 1 Product description Bulk meter for water up to 50 C 2 Applications Measurement of cold potable water up to 30 C for billing applications Measurement of clean water up to 50 C The normal flow rate should differentiate from the changeover flow rate Frequent pass over of the changeover flow rates can shorten the service life During operation a minimum upstream pressure of 0 5 bar must exist With a lower pressure the safe switching of the valve is not ensured 3 Included in the delivery 1 Water meter 2 gaskets 1 manual 4 Technical data Refer to the technical data leaflet LB 1810 http www sensusesaap com 5 Installation instructions 5 1 Safety tips 5 1 1 No mechanical stresses may be exerted on the meter when installed in the pipeline The pipeline flanges must align with the meter flanges and the distance between the flanges must match the meter body length Misalignment stresses can cause the meter body or flanges to crack When the pipeline is under pressure this can cause flooding 5 1 2 The meter must not be subjected to pressures higher than the pressure rating printed on the meter Too high pressure can cause leaks or burst the meter body 5
4. water Installation of a meter at the highest point in a pipeline must be avoided 5 3 10 The manufacturer s Q value should not be exceed during normal operation 5 3 11 The maximum medium temperature of 50 C shall not be exceeded 5 3 12 The meter should be protected from stones sand and fibrous material with a suitable strainer or filter 5 3 13 The meter must be protected from pressure surges 5 3 14 Exchanging the metrological unit e Metrological units must be replaced by metrological units with an identical metrology marking Metrological units with MID approval must be installed only in bodies with the marking MID on the upper flange surface e Before the installation of a replacement metrological unit the inside surface of the body especially the sealing areas of the O ring must be checked for damage The drain screw on the bottom must be removed and the body drained Thereafter the screw can be used again A new gasket for the drain screw and O ring for the measuring insert must be used included in the delivery e The detection of damages on the body or drain screw demands its replacement The body must be cleaned debris must be removed e The O ring and the lip seal must be lubricated with grease approved for use with potable water before installation into the meter body e To avoid damaging the O ring when installing a metrological unit the O ring must first be fitted onto the cover flange and then pushed into the m
5. 2 Installation Tools Two spanners for the corresponding size of bolts used are necessary Hoisting devices may be required depending on the weight of the meter and the installation conditions 5 3 Installation instructions 5 3 1 The MeiTwin acc to its approval does not need any straight upstream or downstream pipe UODO 5 3 2 The pipe diameter should not be abruptly reduced or expanded directly upstream of the meter All diameter changes should be done with an angle lt 8 related to the pipe centre 5 3 3 All flow regulating devices e g Valves PRV s shall be installed downstream of the meter 5 3 4 When choosing an installation site consider the meter orientation horizontal vertical 5 3 5 Gaskets must not protrude into the pipeline or be misaligned 5 3 6 The pipeline must be thoroughly flushed before installing the meter to prevent damage from debris 5 3 7 The flow direction of the meter arrow on the meter body must correspond with the flow direction in the pipeline 5 3 8 After installation of the meter the pipeline must be filled with water very slowly to prevent the meter being damaged by surges In particular with the use of a piston type by pass meter a moderate rotation speed of the sweep hands lt 2 s has to be maintained Too fast evacuation will damage the by pass meter 5 3 9 The installation site should be chosen to prevent air bubbles collecting in the meter and the pipeline must always be completely filled with
6. 5 3 12 El contador debe protegerse de las piedras arena y material fibroso con filtro adaptado 5 3 13 El contador debe protegerse de los golpes de ariete 5 3 14 Cambio del conjunto de inserci n El conjunto de inserci n debe ser reemplazado por un conjunto de inserci n con un marcaje metrol gico id ntico Los conjuntos de inserci n con conformidad MID deben ser instalados nicamente en cuerpos que tengan MID marcado en la superficie superior del aro e Antes de la instalaci n del conjunto de inserci n la superficie interior del cuerpo sobre todo las reas de estanqueidad de la junta debe ser revisada en b squeda de desperfectos El tornillo de drenaje de la parte inferior debe ser extra do para que el cuerpo expulse el agua A posteriori el tornillo se puede utilizar de nuevo Una nueva junta para el tornillo de drenaje as como una junta t rica para el conjunto de inserci n deben ser utilizadas incluidas en la entrega e La detecci n de desperfectos en el cuerpo o en el tornillo de drenaje requerir su sustituci n e El cuerpo del contador debe ser limpiado y la suciedad eliminada La junta t rica y la junta de labio deben ser lubricadas con grasa aprobada para su uso con agua potable antes de ser instaladas en el cuerpo del contador Para evitar da os en la junta t rica al instalar un conjunto de inserci n sta debe encajarse primero en el borde de la tapa y entonces debe empujarse en el cuerpo del con
7. 700 70 Gesch ftsf hrung R diger Guse Klaus Gr bl www sensus com Date 08 December 2011 SENSUS Declaration of Conformity no CE MeiTwin 1211 Herewith we Sensus GmbH Hannover Meineckestra e 10 D 30880 Laatzen Germany declare under our sole responsibility that the meter of the type MeiTwin DN 50 100 to which this declaration relates are in conformity with the legal regulation of the Directive 2004 22 EC of the European Parliament and the Council of the 31 of March 2004 on measuring instruments including e Annex I Essential requirements e Annex MI 001 water meter Applied normative harmonized documents OIML R 49 1 edition 2006 E OIML R 49 2 edition 2004 E DIN EN 14154 1 edition May 2005 D incl annex A1 edition July 2007 D DIN EN 14154 2 edition May 2005 D incl annex A1 edition July 2007 D DIN EN 14154 3 edition May 2005 D incl annex A1 edition July 2007 D Other standards OIML R 49 2 Edition 2006 OIML R 49 3 Edition 2006 DIN EN 14154 1 2005 A2 2011 DIN EN 14154 2 2005 A2 2011 DIN EN 14154 3 2005 A2 2011 ISO 4064 1 2005 ISO 4064 2 2005 ISO 4064 3 2005 The conformity assessment procedure was accomplished under the surveillance of the notified body at SMU Id No 1781 It was issued the type examination certificate SK 11 MIOO1 SMUO20 The Director Quality Management makes this declaration on behalf of the manufacturer Sensus GmbH Hannover ss Sensus GmbH H
8. MB 1810 1 Produktbeschreibung Verbundwasserz hler f r sauberes Wasser bis 50 C 2 Verwendungszweck Zur Messung von Trinkwasser im gesch ftlichen Verkehr bis 30 C Zur Messung von sauberem Brauchwasser bis 50 C Es ist darauf zu achten dass sich der Normaldurchfluss vom Umschaltdurchfluss unterscheidet H ufiges Durchschreiten der Umschaltdurchfl sse kann zur Verk rzung der Nutzungsdauer f hren W hrend des Betriebes muss immer ein Druck von 0 5 bar vor dem Z hler vorhanden sein Bei einem niedrigeren Druck ist das sichere Schalten des Umschaltventils nicht gew hrleistet 3 Lieferumfang 1 Wasserz hler 2 Flanschdichtungen 1 Bedienungsanleitung 4 Technische Daten Siehe technisches Datenblatt LB 1810 http www sensusesaap com 5 Montage 5 1 Gefahrenhinweise 5 1 1 Der Wasserz hler muss mechanisch spannungsfrei in die Rohrleitung eingebaut werden Verspannter Einbau kann zur Zerst rung des Z hlergeh uses f hren Dadurch tritt Wasser aus 5 1 2 Der Rohrleitungsdruck darf nicht h her sein als die Angabe auf dem Typenschild Zu hoher Druck kann zu Undichtigkeiten oder zur Zerst rung des Z hlergeh uses f hren 5 2 Notwendige Werkzeuge Je 2 Schraubenschl ssel bzw Innensechskantschl ssel der Nenngr e der verwendeten Schrauben entsprechend Unter Umst nden ein geeignetes Hebezeug 5 3 Montagehinweise 5 3 1 Der MeiTwin ben tigt gem MID Zulassung keine Ein und Auslaufstrecke UODO 5 3 2 Der Roh
9. annover Telefon 49 0 5102 74 0 Meineckestra e 10 Telefax 49 0 5102 74 3341 D 30880 Laatzen Bankverbindung Deutsche Bank AG Hannover Amtsgericht Hannover HRB 61468 Ust Id Nr DE 115507611 St Nr 27 661 0270 6 Konto 04 44 000 BLZ 250 700 70 Gesch ftsf hrung R diger Guse Klaus Gr bl www sensus com M B 1 Q 1 0 Manuel d installation MeiTwin MID Instrucciones de instalaci n para el MeiTwin rear avec stabilisateur de flux MID con estabilizador de flujo MID 1 Description du produit Compteur d eau industriel jusqu a 50 C 2 Applications Mesure de l eau potable froide jusqu a 30 C pour la facturation Mesure de l eau propre jusqu a 50 C Le d bit d utilisation devra tre diff rent du d bit de commutation Une commutation fr quente du by pass peut raccourcir sa dur e de vie Pendant le fonctionnement en amont une pression minimale de 0 5 bar doit exister Avec une pression plus faible de la commutation le fonctionnement de la soupape n est pas assur e 3 Inclus dans la livraison 1 compteur d eau 2 joints 1 manuel d installation 4 Donn es techniques Se r f rer la fiche technique LB 1810 http www sensusesaap com 5 Manuel d installation 5 1 Instructions de s curit 5 1 1 Aucune tension m canique ne doit tre exerc e sur le compteur lors son installation sur la conduite Les brides de la canalisation doivent tre align es avec les brides du compteur et la distance en
10. arons sous notre responsabilit unique que le s compteur s d eau de s mod les suivants MeiTwin DN 50 100 Respectivement pour lesquels cette d claration est li e sont en conformit avec les dispositions l gales de la directive 2004 22 EC du Parlement Europ en et du Conseil du 31 mars 2004 sur les instruments de mesure incluant e Annexe I Exigences essentielles e Annexe MI 001 Compteurs d eau Les documents normatifs et harmonis s applicables OIML R 49 1 dition 2006 E OIML R 49 2 dition 2004 E DIN EN 14154 1 dition Mai 2005 D avec l annexe Af dition Juillet 2007 D DIN EN 14154 2 edition Mai 2005 D avec l annexe A1 dition Juillet 2007 D DIN EN 14154 3 dition Mai 2005 D avec lannexe A1 dition Juillet 2007 D Autres normes OIML R 49 2 Edition 2006 OIML R 49 3 Edition 2006 DIN EN 14154 1 2005 A2 2011 DIN EN 14154 2 2005 A2 2011 DIN EN 14154 3 2005 A2 2011 ISO 4064 1 2005 ISO 4064 2 2005 ISO 4064 3 2005 Cette demande d obtention de d claration de conformit a t r alis e sous le contr le de l organisme notifi SMU sous le No 1781 Le certificat d examen de type de ce produit tant le N SK 11 MI001 SMU020 Cette d claration est faite au nom du fabricant par le Directeur du Management de la Qualit Sensus GmbH Hannover Telefon 49 0 5102 74 0 Meineckestra e 10 Telefax 49 0 5102 74 3341 D 30880 Laatzen Bankverbindung Deutsche Bank AG Han
11. en Dichtungssitz gedr ckt werden Dabei muss die Pfeilrichtung auf dem Deckelflansch und dem Geh use gleich sein e Die Messeinsatzschrauben werden per Hand eingeschraubt und ber Kreuz mit einem passenden Schl ssel angezogen Bei O Ring Dichtungen ist das Anzugsmoment 160Nm M16 e Um Manipulationen vorzubeugen muss bei Z hlern im gesch ftlichen Verkehr eine Schraube des Messeinsatzes durch eine Nutzerplombe gegen das Geh use gesichert werden 6 Ablesung Bei der Ablesung eines Verbundwasserz hlers m ssen immer beide Z hlwerke Haupt und Nebenz hler abgelesen werden Der Verbrauch ist immer die Summe beider Z hler Bei der Ablesung des Z hlers werden volle Kubikmeter durch schwarze Zahlenrollen angezeigt Teile von Kubikmetern werden durch rote Zahlenrollen oder Zeiger angezeigt 7 Wartung und Reinigung Unter normalen Betriebsbedingungen arbeitet der Z hler wartungsfrei Bei Bedarf kann der Messeinsatz aus dem Geh use entfernt und gereinigt werden F r die Reinigung d rfen keine Chemikalien Hochdruckreiniger oder scharfkantigen Werkzeuge verwendet werden WWW SeENSUS COM MB 1810 INT4 0002 info de sensus com info int sensus com Installationsanweisung MeiTwin mit Str munggsgleichrichter MID 8 Transport Z hlerkopf Register Rohrleitung Pipe 3 Hauptz hler DN 50 100 Main meter DN 50 100 MeiTwin mit Nebenz hler MeiTwin with By Pass
12. eter body If the O ring is fitted into the body first it can be pinched when fitting the meter insert and cause leaks e When installing the metrological unit into the meter body make sure that the direction of the arrow on the head flange aligns with the arrow on the meter body e The screws fixing the metrological unit in the body shall be screwed hand tight and then tightened crosswise with an Allen key The recommended torque is max 160 Nm M16 e With meters used for billing at least one screw of the metrological unit shall be sealed against the meter body after the exchange to avoid tampering 6 Reading When reading a compound meter always both indexes main and by pass meter must be read The consumption is always the total of both meters The black digits on the roller counter indicate full cubic metres Parts of a cubic metre are indicated by red rollers and or red sweep hands 7 Maintenance and cleaning Under normal conditions the meter is maintenance free If required the measuring insert can be removed from the body and be cleaned Chemicals sharp objects or high pressure cleaners must not be used for cleaning sEnsus g englisch meitwin doc 121208_konformit tserkl run g deutsch meitwin doc 121208_konformit tserkl run Datum 08 12 2011 Konformit tserkl rung Nr CE MeiTwin 1211 Hiermit erkl ren wir Sensus GmbH Hannover Meineckestra e 10 30880 Laatzen in alleiniger Verantwortung f
13. nover Amtsgericht Hannover HRB 61468 Ust Id Nr DE 115507611 St Nr 27 661 0270 6 Konto 04 44 000 BLZ 250 700 70 Gesch ftsf hrung R diger Guse Klaus Gr bl www sensus com Fecha 08 Diciembre 2011 Declaraci n de Conformidad no CE MeiTwin 1211 Por la presente Sensus GmbH Hannover Meineckestra e 10 D 30880 Laatzen Germany declara bajo propia responsabilidad que el los contador es de los siguiente s tipo s MeiTwin DN 50 100 al cual esta declaraci n hace referencia es son conforme s a la regulaci n legal de la Directiva 2004 22 ECC del Parlamento Europeo y del Consejo del 31 de marzo de 2004 sobre instrumentos de medida incluyendo e Anexo l Requisitos esenciales e Anexo MI 001 Contadores de agua normativas aplicadas documentos armonizados e OIML R 49 1 edici n 2006 E OIML R 49 2 edici n 2004 E DIN EN 14154 1 edici n Mayo 2005 D con anexo A1 edici n Julio 2007 D DIN EN 14154 2 edici n Mayo 2005 D con anexo A1 edici n Julio 2007 D DIN EN 14154 3 edici n Mayo 2005 D con anexo A1 edici n Julio 2007 D otras normas OIML R 49 2 Edici n 2006 OIML R 49 3 Edici n 2006 DIN EN 14154 1 2005 A2 2011 DIN EN 14154 2 2005 A2 2011 DIN EN 14154 3 2005 A2 2011 ISO 4064 1 2005 ISO 4064 2 2005 ISO 4064 3 2005 El procedimiento de evaluaci n de la conformidad se llev a cabo bajo la supervisi n del organismo notificado en SMU Id No 1781 Fue emitido el certificado de
14. on 6 Lecture Sur un compteur conbin la consommation totale correspond a la somme de l index du compteur principal et du compteur by pass Les chiffres noirs des rouleaux indiquent les m Les sousmultiples sont indiqu s par les pointeurs rouges 7 Maintenance et entretien Aucune maintenance n est requise dans des conditions normales d utilisation Aucun produit chimique objet tranchant ou nettoyeur haute pression ne doit tre utilis pour l entretien du compteur WWw Sensus com MB 1810 INT4 0002 info fr sensus com info es sensus com 8 Transport Transporte MeiTwin avec compteur by pass MeiTwin con contador de paso 612MTW 612MTW HRI et y 612MTW ER56 Totalisateur Totalizador Vers le haut ou inclin Hacia arriba inclinado Conduite Tuber a horizontal horizontale vertical verticale Compteur principal DN 50 100 Compteur by bass Contador principal DN 50 100 Contador de paso 1 Descripci n del producto Contador industrial para agua hasta 50 C 2 Aplicaciones Medici n de agua potable fr a hasta 30 C para aplicaciones de facturaci n Medici n de agua limpia hasta 50 C El caudal normal de trabajo deber a diferenciarse del caudal de conmutaci n Conmutaciones frecuentes por este motivo podr an acortar la vida del equipo Durante la operaci n una presi n
15. oy e La vis de vidange doit tre retiree et le corps vid de son eau Par la suite la vis peut tre utilis e a nouveau Installer un nouveau joint pour la vis de vidange et le joint torique de l insert de mesure doit tre utilis inclus dans la livraison La d tection de dommages sur la vis de vidange ou le corps du compteur exige leurs remplacements e Le corps doit tre nettoy les d bris doivent tre enlev s Le joint torique et le joint a l vre doit tre lubrifi e avec de la graisse approuv e pour l utilisation avec de l eau potable avant montage dans le corps du compteur Pour viter d abimer le joint torique lors de l installation de l unit m trologique il doit d abord tre install autour du m canisme qui est ensuite introduit dans le corps du compteur Si le joint torique est mont en premier sur le corps il peut tre pinc lors du montage du m canisme de mesure et causer des fuites Lors de l installation de l unit m trologique dans le corps du compteur assurez vous que le sens de la fleche pr sente sur la bride de la t te soit align e avec la fleche indiqu e sur le corps du compteur e Les vis fixant l unit m trologique sur le corps doivent tre viss es la main puis serr es l aide d une cl Allen Le couple recommand est de 160 Nm vis M16 Au moins une des vis fixant l unit m trologique doit tre scell e pour viter la fraude des compteurs servant a la facturati
16. r Todos los cambios del di metro deben hacerse con un ngulo lt 8 relacionado al centro de la tuber a 5 3 3 Cualquier tipo de dispositivo regulador de caudal por ej v lvulas debe instalarse aguas abajo del contador 5 3 4 Cuando elija un lugar de instalaci n considere la orientaci n del contador horizontal vertical 5 3 5 Las juntas no deben sobresalir en la tuber a o estar desalineadas 5 3 6 La tuber a debe limpiarse completamente antes de instalar el contador para prevenir el da o por escombros 5 3 7 La direcci n del flujo en el contador flecha en el cuerpo del contador debe coincidir con la direcci n del flujo de la tuber a 5 3 8 Despu s de la instalaci n del contador la tuber a debe llenarse de agua muy despacio para prevenir que el contador sea da ado por los golpes de ariete En particular con el uso de un contador de paso volum trico una velocidad moderada de rotaci n de los punteros lt 2 s debe ser mantenida Una evacuaci n demasiado r pida da ar a el contador de paso 5 3 9 El lugar de instalaci n deber a ser escogido para prevenir burbujas de aire en el contador y la tuber a siempre debe estar completamente llena de agua Debe evitarse la instalaci n de un contador en el punto m s alto de la tuber a 5 3 10 El valor de Q facilitado por el fabricante no deber a excederse durante la operaci n normal del equipo 5 3 11 La temperatura m xima del medio no debe exceder los 50 C
17. r die von uns hergestellten Wasserz hler des Typs MeiTwin DN 50 100 Konformit t mit den Rechtsvorschriften der Richtlinie 2004 22 EG des europ ischen Parlaments und des Rates ber Messger te vom 31 M rz 2004 einschlie lich Anhang I Grundlegende Anforderungen Anhang MI 001 Wasserz hler Angewendete harmonisierte Normen bzw normative Dokumente OIML R 49 1 Edition 2006 E OIML R 49 2 Edition 2004 E DIN EN 14154 1 Edition Mai 2005 D mit Anhang A1 Ausgabe Juli 2007 D DIN EN 14154 2 Edition Mai 2005 D mit Anhang A1 Ausgabe Juli 2007 D DIN EN 14154 3 Edition Mai 2005 D mit Anhang A1 Ausgabe Juli 2007 D Weitere angewendete Regeln OIML R 49 2 Edition 2006 OIML R 49 3 Edition 2006 DIN EN 14154 1 2005 A2 2011 DIN EN 14154 2 2005 A2 2011 DIN EN 14154 3 2005 A2 2011 ISO 4064 1 2005 ISO 4064 2 2005 ISO 4064 3 2005 Das Konformit tsbewertungsverfahren wurde unter der Aufsicht der benannten Stelle SMU Kennnummer 1781 durchgef hrt Es wurde die Baumusterpr fbescheinigung SK 11 MI001 SMUO20 ausgestellt Diese Erkl rung wird verantwortlich f r den Hersteller abgegeben durch den Direktor Qualit tsmanagement Sensus GmbH Hannover W Sensus GmbH Hannover Telefon 49 0 5102 74 0 Meineckestra e 10 Telefax 49 0 5102 74 3341 D 30880 Laatzen Bankverbindung Deutsche Bank AG Hannover Amtsgericht Hannover HRB 61468 Ust Id Nr DE 115507611 St Nr 27 661 0270 6 Konto 04 44 000 BLZ 250
18. rleitungsquerschnitt sollte direkt vor dem Z hler nicht abrupt reduziert bzw erweitert werden Alle Querschnitts nderungen sollten mit einem Winkel lt 8 vorgenommen werden 5 3 3 Bauteile zur Durchflussregulierung z B Ventile sollten hinter dem Z hler montiert werden 5 3 4 Bei der Auswahl der Einbaustelle beachten Sie bitte die vorgeschriebene Einbaulage horizontal vertikal 5 3 5 Flanschdichtungen d rfen nicht in die Rohrleitung hineinragen 5 3 6 Vor der Installation des Z hlers muss die Rohrleitung sorgf ltig gesp lt werden 5 3 7 Es ist darauf zu achten dass die Durchflussrichtung des Z hlers Kennzeichnung auf dem Geh use mit der Hauptdurchflussrichtung der Rohrleitung bereinstimmt 5 3 8 Nach der Installation muss die Rohrleitung langsam gef llt werden um Besch digungen des Messeinsatzes durch Druckschl ge auszuschlie en Insbesondere bei Verwendung eines Ringkolbenz hlers als Nebenz hler muss auf eine gem igte Drehzahl der Zeiger lt 2U sec geachtet werden Zu schnelles Entl ften f hrt zur Zerst rung des Nebenz hlers 5 3 9 Die Einbaustelle sollte so gew hlt werden dass sich keine Luftblasen im Z hler bilden k nnen und die Rohrleitung immer vollst ndig gef llt ist Der Z hler sollte nie an der h chsten Stelle der Rohrleitung installiert werden 5 3 10 Die Herstellerangabe des Q sollte im Normalbetrieb nicht berschritten werden 5 3 11 Die maximale Medientemperatur darf 50 C nicht be
19. rschreiten 5 3 12 Der Z hler sollte vor Steinen Sand und Fasern durch einen geeigneten Filter gesch tzt werden 5 3 13 Der Z hler muss durch geeignete Ma nahmen vor Druckschl gen in der Rohrleitung gesch tzt werden 5 3 14 Messeinsatzwechsel e Messeins tze d rfen nur durch Messeins tze mit gleicher Metrologie Kennzeichnung ersetzt werden Messeins tze mit MID Zulassung d rfen nur in Geh use mit der Kennzeichnung MID auf der Kopfflanschfl che eingebaut werden Vor dem Einbau eines neuen Messeinsatzes m ssen die Dichtungssitze und das Innere des Geh uses auf Besch digungen berpr ft werden Die Ablassschraube am Boden des Geh uses muss entfernt und die Rohrleitung entleert werden Dabei darf die Schraube wiederverwendet werden Die Dichtung muss ersetzt werden ist im Lieferumfang des neuen Messeinsatzes enthalten Gebrauchte Dichtungen d rfen nicht wiederverwendet werden Bei Besch digungen muss das Geh use oder die Ablassschraube ersetzt werden e Das Geh use muss gereinigt werden Ablagerungen m ssen entfernt werden e Die O Ring Dichtung und die Formdichtung am Messeinsatz muss vor der Montage mit lebensmitteltauglichem Fett bestrichen werden e Die O Ring Dichtung muss auf den Sitz am Messeinsatz aufgezogen werden um Besch digungen und damit verbundene Undichtigkeiten zu vermeiden Sie darf auf keinen Fall in das Geh use eingelegt werden e Der Messeinsatz muss vorsichtig ins Geh use eingesetzt und in d
20. tador e Cuando instale el conjunto de inserci n en el cuerpo del contador debe estar seguro que la direcci n de la flecha del conjunto coincide con la de la flecha del cuerpo del contador e Los tornillos que fijan el conjunto de inserci n en el cuerpo deben ser atornillados a mano y apretados finalmente con una llave Allen En contadores usados para facturaci n por lo menos uno de los tornillos debe ser precintado al cuerpo del contador despu s de intercambiar el conjunto de inserci n para evitar ser manipulado 6 Lectura Al realizar la lectura de un contador combinado siempre se deben leer los dos ndices contador principal y de paso El consumo es siempre el total de ambos consumos Los n meros de color negro del rodillo de la esfera indican metros c bicos enteros Los subm ltiplos de metros c bicos est n indicados por los punteros rojos del totalizador 7 Mantenimiento y limpieza Bajo las condiciones normales el contador est libre de mantenimiento Si se requiere el conjunto de inserci n puede extraerse del cuerpo del contador y ser limpiado Para limpiar no deben usarse productos qu micos objetos afilados o limpiadores de alta presi n SENSUS g franz sisch meitwin doc 121208_konformit tserkl run g spanisch meitwin doc 121208_konformit tserkl run Declaration de Conformite no CE MeiTwin 1211 Par la pr sente nous Sensus GmbH Hannover Meineckestra e 10 D 30880 Laatzen Germany D cl
21. tre les brides doit correspondre la longueur du corps du compteur Les pressions dues un mauvais alignement peuvent g n rer une fissuration du corps ou des brides du compteur Lorsque la canalisation est sous pression ces fissures peuvent g n rer des inondations 5 1 2 Le compteur ne doit pas tre soumis a une pression sup rieure celle figurant sur son corps Des pressions lev es peuvent provoquer des fuites ou l explosion du compteur 5 2 Outils n cessaires l installation Deux clefs de serrage de dimension adapt e Un palan peut tre n cessaire selon le poids du compteur et les conditions d installation 5 3 Instructions d installation 5 3 1 Le MeiTwin selon son approbation ne n cessite pas de longueur droite en amont et en aval 5 3 2 La canalisation ne doit pas subir de variations brutales du diam tre directement en amont du compteur Tous les changements de diam tre seront r alis s avec un angle lt 8 par rapport au centre de la canalisation 5 3 3 Tous les quipements de r gulation ex vannes r gulateurs de pression doivent tre install s en aval du compteur 5 3 4 V rifier que le site permet de respecter les conditions d installation horizontale ou verticale du compteur 5 3 5 Les joints ne doivent pas perturber le bon coulement v rifier le centrage et l alignement des joints 5 3 6 La conduite doit tre rinc e soigneusement avant l installation du compteur afin d viter des d g
22. ts pouvant tre caus s par des d bris 5 3 7 S assurer que le compteur est install dans le sens de l coulement indiqu par les fl ches sur le corps 5 3 8 Apr s l installation du compteur la canalisation doit tre mis en eau progressivement pour pr venir tous dommages du m canisme du compteur En particulier avec l utilisation d un compteur by pass type volum trique une vitesse de rotation mod r e du piston lt 2s doit tre maintenue Une vacuation trop rapide peut endommager le compteur de by pass 5 3 9 Le compteur doit tre install sur un point bas de la conduite et la canalisation doit tre compl tement compl tement noy e afin d viter la formation de poches d air 5 3 10 Le d bit Q constructeur ne devra pas tre d pass pendant des p riodes prolong es 5 3 11 La temp rature de l eau maximale de 50 C ne doit pas tre d pass e 5 3 12 Le compteur doit tre prot g du sable des pierres et de tout mat riau fibreux par un filtre adapt 5 3 13 Le compteur doit tre prot g des coups de b lier 5 3 14 Changement du m canisme de mesure Le m canisme de mesure doit tre remplac par un m canisme de mesure identique avec marquage m trologique Le m canisme de mesure ayant une approbation MID doit tre install uniquement dans un corps ayant un marquage MID Avant l installation d un m canisme de mesure dans un nouveau corps la zone d tanch it du joint torique doit tre nett