Contents
1. ITEM PART NO DESCRIPTION 1 2056599 Gas Spring 2 2337692 Gas Spring Release Sub Assembly 3 2346599 Clevis Pin 7 16 x 1 1 2 Zinc 4 2346103 Armrest RH 5 2346203 Armrest LH 6 0705899 H H C S 1 4 20 x 50 7 0904499 Bundle Strap 8 2061399 1 25 O D Die Spring 9 2061499 Spring Guide 10 2061699 R H M S 10 24 x 1 1 2 Phillips 11 0729999 Flat Washer 12 0396299 Washer Spring Bow 270 S 12 13 0569499 3 16 Dia x 3 4 Roll Pin 14 2055499 Handle Block 15 1992799 2 Velcro Hook 16 2737203 Tilt Release Bar 17 2737399 Tilt Release Bar Mount 18 2056699 Tilt Release Mount RH 19 2342303 Seat Frame Weldment 20 2342203 Footrest 21 2058099 Bolt Shoulder 5 16 x 1 3 4 22 206059
2. 9 TROUBLESHOOTING GUIDE 11 CLEANING AND MAINTENANCE 12 PARTS 14 Model 520 Chair Assembly 15 Chair Top 16 Chair Base Assembly 18 Lift Assembly 20 Headrest Assembly 22 Wiring Diagram 520 24 LIMITED WARRANT dede 27 IMPORTANT INFORMATION SAFETY SYMBOLS Type B Applied Part DANGER WARNING or CAUTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in this Installation and Operating Instructions Dangerous Voltage Shock Hazard Fuse Rating Specification DANGER AVERTISSEMENT ou PR CAUTION point d exclamation l int rieur d un triangle quilat ral vise alerter l utilisateur la pr sence d importantes instructions de fonctionnement et de maintenance service dans ce manuel d installation et d instructions de fonctionnement Protective Earth Ground Alternating Current AC NOTE Amplifies a procedure practice or condition
3. 1 ADJUST GAS SPRING 2 REPLACE GAS SPRING IN 520 11 12 CLEANING AND MAINTENANCE Cleaning the Upholstery When cleaning upholstery it is suggested that you use all recommended commercial cleaning agents in an inconspicu ous spot to check for potential damage to the upholstery material before applying to the entire area to be cleaned Day to Day soil Remove ordinary dirt and smudges with a mild soap and warm water solution Dry with a soft lint free cloth or towel For more difficult stains use of a stronger detergent is recommended however follow the detergent manufacturer s instructions closely Disinfecting Material In order to disinfect use a 1 9 solution of bleach and water 1 part bleach to 9 parts water Wipe surface with damp cloth then rinse with water immediately using a damp cloth Special cleaning problems The following methods are recommended to clean stains on PreFixx protected vinyl upholstery Most stains will be removed when these cleaning agents are used in the fol lowing order Type 1 Cleaners Nonabrasive household cleaners to be used with water and a soft cloth 9 Formula 409 All Purpose Spray Cleaner e Fantastik Spray Cleaner e Other similar household cleaners and bleaches Type 2 Cleaners Solventtype cleaner to be liberally applied with a soft cloth Dry area with another cloth rinse with clean water and dry e Rubbing alcohol isopropyl
4. 9 REMARQUE Amplifieuneproc dure pratique oucondition Safe Working Load Attention Consult Accompanying Documents Lo I gt gt TRANSPORTATION STORAGE CONDITIONS Temperature Operating 59 to 104 F 15 to 40 C Storage 22 to 140 F 30 to 460 Relative Humidity Operating 5 to 95 without condensation Storage 10 to 100 including condensation Atmospheric Pressure Operating 700hPa 1060hPa Storage 500hPa 1060hPa IN 520 1 INTRODUCTION 1 1 This manual contains information applicable only to the Reliance Model 520 Chair 1 2 Whenever you see the symbols shown below heed their instructions Always follow safe operating and maintenance practices DANGER THE DANGER SYMBOL IDENTIFIES SPECIAL INSTRUCTIONS OR PROCEDURES WHICH IF NOT CORRECTLY FOLLOWED COULD RESULT IN LOSS OF LIFE OR PERSONAL INJURY DANGER LE SYMBOLE DANGER IDENTIFIE DES INSTRUCTIONS OU PROCEDURES SPECIALES QUI SI ELLES NE SONT PAS SUIVIES CORRECTEMENT POURRAIENT CAUSER UNE PERTE DE VIE OU UNE BLESSURE WARNING THE WARNING SYMBOL IDENTIFIES SPECIAL INSTRUCTIONS OR PROCEDURES WHICH IF NOT CORRECTLY FOLLOWED COULD RESULT IN PERSONAL INJURY AVERTISSEMENT LE SYMBOLE AVERTISSEMENT IDENTIFIE DES INSTRUCTIONS OU PROCEDURES SPECIALES QUI SI ELLES NE SONT PAS SUIVIES CORRECTEMENT POURRAIENT CAUSER UNE BLESSURE CAUTION This caution symbol identifie
5. 666 9L AOSZ VO t AO Z M2V19 66cv 9L AOSZ V 9 AOcL jagav S3S 1d SNOILVIA3H88V HO OO SHIM J10V1d303U 2 HIVHO 22 268022 o AT8W3SSV OV OQ M o 9 g O 8 H WH 18 INdNI OV 55 a18vo 661 661 318VO 310SNO2 1003 6615005 ADES c6EE66 6624661 501 15 26102 2 0 2 Ne HOLIMS PR g 2600222 HOLOW D p T N NI LNA Va 1001 31OSNOO D lt OWO OWO H aoa x AlddNS dad4na ANY I3H d3MOd WOlLdO yt H NIL 0000000000000000 AOE 8 ANC 66SGCOS LINDYID AN _ 92 268 0 1 A0 Z 2644021 ADZL d A18IN3SSV GION3 IOS E LL 9 9 D 9 N 9 9 L 24 IN 520 NOTES 25 26 NOTES IN 520 LIMITED WARRANTY The Reliance product must be used only for the purposes and in the manner described in the literature distributed with the product The products are warranted against defective materials and workmanship for the period set forth in the warranty provided with each product Products or parts thereof will be repaired or replaced as required at Reliance amp Medical Products Inc Such repair or replacement shall be the sole remedy under this warranty This warranty extends only to the original purchaser from an authorized Reliance
6. DURING ASCENT CHAIR BASE WILL NOT RAISE OR LOWER FROM FLOOR UNIT CHAIR TOP WOBBLES ON CHAIR BASE CHAIR BACK RECLINES FULLY WITHOUT HANDLE BEING ACTIVATED 1 FOOTSWITCH CORD NOT CONNECTED 1 SOLENOID VALVE NOT CLOSED DIRT IN VALVE 2 CONSTANT POWER APPLIED TO SOLENOID 3 OTHER 1 NO POWER TO SOLENOID ASS Y 2 SOLENOID COIL BURNED OUT 3 OTHER UP LIMIT SWITCH STUCK OPEN PUMP MOTOR BURNED OUT OTHER NO POWER TO MOTOR PUMP ASS Y 1 SOLENOID VALVE NOT CLOSED DIRT IN VALVE 2 CONSTANT POWER APPLIED TO SOLENOID 3 OTHER 1 HYDRAULIC FLUID LEVEL IS LOW 1 CHAIR CONTROL CABLE NOT PLUGGED IN 2 BLOWN FUSE IN CHAIR BASE 1 LOCK NUT IS LOOSE UNDER SEAT BOARD 1 GAS SPRING IN NEED OF ADJUSTMENT 2 GAS SPRING FAILURE 1 CHECK ALL INTERNAL AND EXTERNAL FOOTSWITCH WIRING 1 REPAIR OR REPLACE SOLENOID VALVE 2 CHECK FOR SWITCHES STUCK CLOSED 3 CONTACT FACTORY 1 CHECK FOR VOLTAGE 2 REPLACE SOLENOID COIL 3 CONTACT FACTORY CHECK FOR VOLTAGE RE ADJUST OR REPLACE SWITCH REPLACE MOTOR PUMP ASS Y CONTACT FACTORY AUN REPAIR OR REPLACE SOLENOID VALVE CHECK FOR SWITCHES STUCK CLOSED CONTACT FACTORY gt CONTACT DEALER OR FACTORY FOR INFORMATION ON ADDING OIL CHECK CABLE CONNECTIONS AT STAND CHAIR REPLACE FUSE m TIGHTEN LOCK NUT
7. 1454699 Pin 29 0446099 Snap Ring 0485199 Nut Acorn 5 16 30 0741799 Valve Ball 0 0365799 Gasket Tie Rod 31 0731199 O Ring 0432599 Base Column Seal 32 0441999 Valve Seat 0903292 Cylinder Assembly High 33 1012499 Valve Housing 0526792 Cylinder Assembly Low 34 0363299 Relief Valve Plunger Spacer Cylinder in Item 12 35 0784699 Relief Valve Spring Bushing in Item 12 36 1012399 Set Screw Ring Quad in Item 12 37 0731299 O Ring 0902285 Base Column High 38 0442499 Valve Spring 0563885 Base Column Low 39 17 0432599 0901999 0563699 20 0422899 1183592 1183692 To order complete Base Assembly use P N s 2 21192 Lift Assembly Low 2 21292 Lift Assembly High Please specify paint color when ordering IN 520 21 22 FIGURE 9 HEADREST ASSEMBLY IN 520 roms oro OR 13 To order complete Headrest Assembly use P N 2059592 Headrest Assembly Please specify paint color when ordering Please specify upholstery color when ordering IN 520 23 FIGURE 10 WIRING DIAGRAM IN 520 c6v9bvee AIEINASSV HOLIMS1001 MOTISA jSV8 YIVHO A M ae y dONVHO O AVEO AO NS H8 78 662659 A 1HIN3SSV QHOO H3MOd 66 9 61 310GOIN AH LN3 YIMOd N3JH49
8. 18 IN 520 ST oe MARIE TS NOTE Power cord for 230V base does not f include a plug NOTE Le cordon de secteur pour la base 230V ne comprend pas une fiche To order complete Base Assembly use P N s 2 24092 Chair Base Assembly Low 120V 2 24192 Chair Base Assembly High 120V 2 24292 Chair Base Assembly Low 230V 2724392 Chair Base Assembly High 230V Please specify paint color when ordering IN 520 19 20 c 21 22 23 74 24 25 2 4 36 25 35 34 LT 33 amp 37 i 18 A MM TW x 32 aL FIGURE 8 LIFT ASSEMBLY 43 IN 520 ITEM PART NO DESCRIPTION ITEM PART NO DESCRIPTION 1 1012795 Lift Base 22 0733299 Retaining Ring 1019095 Lift Top 23 0512599 Backup Ring 0439979 Switch Plate 24 0730899 Pack 0929699 Insulator 25 0512499 Piston Ring 1011399 Switch 26 0353199 Cylinder Gasket 0727599 Drive Screw 27 0569299 Pin Roll 0731499 O Ring 28 0466399 Filter Screen
9. 513 398 3937 Http www reliance medical com P N 20607 REV J Copyright 2007 Printed in U S A Revised 02 2012 7929
10. appelee la position d utilisation pr vue Avant d incliner un patient assurez vous que le dossier de la chaise est align avec le r ceptacle d alimentation de la chaise et que le pivot de la chaise est verrouill La charge de travail s curitaire est r duite si la chaise est tourn e hors de sa position d utilisation pr vue et cela pourrait causer une stabilit insuffisante CAUTION This exam Chair is designed for use with a specific maximum patient weight as a static non moving load Sudden weight shifts or impact loads can exceed the safe static load rating of this Chair and may result in insufficient stability PR CAUTION Cette chaise d examen est concue pour utilisation avec un poids de patient maximum sp cifique comme charge statique sans mouvement Les d placements de poids soudains ou les charges dynamiques peuvent exc der la norme de charge statique s curitaire de la chaise ce qui pourrait causer une stabilit insuffisante CAUTION This exam Chair is designed for use with a patient properly positioned in the Chair Prior to reclining the Chair ensure that the patient is seated in the Chair and that the patient position does not move to an extreme position either toward the head of the Chair or toward the foot of the Chair since this may result in insufficient stability PR CAUTION Cette chaise d examen est concue pour utilisation avec un patient correctement positionn d
11. dealer and is subject to the following conditions 1 The warranty card must be completed and returned to Reliance Medical Products Inc within two 2 weeks from the date of installation 2 Installation and servicing of the products must be performed by trained Reliance equipment dealer service personnel in accordance with the appropriate instructions manual for the products 3 The products have not sustained breakage or other type damage due to accident or misuse 4 This warranty will not apply to Reliance products which have had the serial number removed altered or effaced EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE RELIANCE amp DOES NOT GRANT ANY WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILTY OR FITNESS FOR A PARTICULAR USE Reliance Medical Products neither assumes nor authorizes any person to assume for it any other liability in connection with the sale and use of its products REMEDIES ARE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT OF PARTS RELIANCE MEDICAL PRODUCTS INC EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE RESULTING FROM THE USE OF THE EQUIPMENT Claims covered by this warranty will be honored when presented within one 1 month from discovery of a defect IN 520 27 E RELIANCE INTERNATIONAL MADE IN AMERICA 3535 Kings Mills Road Mason Ohio 45040 2303 1 800 735 0357 Customer Service 1 800 735 0358 Technical Service
12. lift e Depress the left side of the pedal to lower the Chair lift NOTE The RAISE and LOWER BASE switches f on the Footswitch are programmable By design the motion of the Chair will STOP when either of these switches is released If you want the motion of the Chair to CONTINUE after either of these switches is released then see Section 4 for programming instructions REMARQUE Les interrupteurs RAISE LEVER et LOWER BAISSER la base sur l interrupteur au pied sont programmables Selon la conception initiale le mouvement de la chaise S ARRETE lorsque l un ou l autre de ces interrupteurs est rel ch Si vous d sirez que le mouvement de la chaise CONTINUE apr s que l un ou l autre de ces interrupteurs est rel ch consultez la section 4 pour connaitre les Instructions de programmation FIGURE 2 FOOTSWITCH OPERATION 3 2 Chair Top 3 2 1 Positioning The Chair Top e he Chair top may be manually tilted To do so release the lock by squeezing the Release Lever and the Grab Bar on the back of the Chair together Push back to recline Release two bars to lock top in desired position Figure 3 WARNING FIRM CONTROL OF THE CHAIR TOP MUST BE MAINTAINED DURING THE RECLINING OPERATION THIS IS ESPECIALLY IMPORTANT WITH HEAVIER OR LIGHTE
13. painted items and plastic covers are as follows e Cavicide Hospital Disinfectant e Precise Hospital Foam Cleaner Disinfectant CAUTION Follow manufacturer s directions for and application of disinfecting cleaner Avoid prolonged application of any disinfectant cleaner products because they may cause staining or discoloration of material PRECAUTION Suivez les instructions du fabricant pour la concentration et l application de nettoyeurs d sinfectants Evitez une application prolong e de tout produit d sinfectant nettoyant parce que ceux ci pourraient causer des taches ou une decoloration du materiel IN 520 IN 520 NOTES 13 PARTS LIST RELIANCE MODEL 520 EXAMINATION AND TREATMENT CHAIR P When ordering parts please 1 Advise dealer or factory of model and serial number of unit These numbers are on the plate that is located at rear near bottom of Chair back 2 Specify color of painted parts Painted parts have an asterisk behind the part description Lorsque vous commandez des pi ces veuillez 1 Informez le distributeur ou l usine du mod le et du num ro de s rie de l ensemble Ces num ros sont de la plaque qui est situ e l arri re pr s du bas de l arri re de pr sidence 2 Sp cifier la couleur des pi ces peintes Les pi ces peintes ont un ast risque 7 derri re la description de pi ce Should your Chair not perform properly or if replacement
14. 9 Tilt Release Mount LH 23 0722699 S H S S 1 4 20 x 25 K C P 24 Headrest Assembly See Figure 9 25 0643599 Lock Plug 26 2059399 Bottom Cover 27 2059299 Back Cover 28 2839099 Bolt Shoulder 1 2 x 300 ITEM PART NO DESCRIPTION 29 0297899 1 4 Retaining Rng 30 2060099 Spacer 50 OD x 31 I D x 5 31 2060699 Cable Lever 32 2062103 Grab Bar 33 1782799 H H C S 1 4 20 x 3 4 34 1638599 R H M S 10 24 x 63 Phil 35 2055599 Knob 520 36 2780699 Washer 317x 739 x 06 37 0561799 Locking Cam 38 0728899 Lockwasher 10 39 2055185 Seat Support 40 0728299 Lockwasher 1 4 Split 41 1036799 H H C S 5 16 18 x 63 42 0789199 R H M S 10 24 x 38 Phil 43 1512299 S H C S 1 4 20 X 63 44 2058699 Control Cable Assembly 45 0508599 Lock Nut 3 8 16 Thin 46 0712299 FH M S 1 4 20 x 50 Phil 47 0789399 S H C S 5 16 18 x 1 25 48 0705699 10 24 Keps Nut 49 0704699 5 16 18 Keps Nut 50 0703699 1 4 20 Keps Nut 51 0604599 Mounting Screw 52 0722899 S H S S 1 4 20 x 38 53 0295699 1 4 28 Jam Nut 54 0807799 S H C S 1 4 20 x 375 55 2055699 Lock Handle RH 56 2055799 Lock Handle LH IN 520 Please specify paint color when ordering FIGURE 7 CHAIR BASE ASSEMBLY Y CL Sa RL 7
15. ES AVERTISSEMENT RISQUE D EXPLOSION POTENTIAL ELECTROMAGNETIC or OTHER INTERFERENCE This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off andon the user is encouragedto tryto correctthe interference by one or more of the following measures e Reorient or relocate the receiving device e Increase the separation between the equipment e Connectthe equipment into an outlet on a circuit different from that to which the other device s are connected e Consult the manufacturer or field service technician for help WARNING STORAGE OF THIS EQUIPMENT 40 4 4 WILL CAUSE THE HYDRAULIC OIL TO BECOME THICK THIS MAY CAUSE UNUSUAL NOISES WHEN THE BASE MOTOR IS OPERATED IT IS RECOMMENDED THAT THE EQUIPMENT STAY AT A TEMPERATURE OF 60 F 15 6 C OR ABOVE FOR AT LEAST 8 HOURS BEFORE OPERATING CET EQUIPEMENT A MOINS DE 4 4 C 40 F FERA EN SORTE QUE L HUILE HYDRAULIQUE DEVIENDRA EPAISSE CECI POURRAIT CAUSER DES BRUITS INHABITUELS LORSQUE LE MOTEUR DELA BASE FONCTIONNE ON RECOMMANDE QUE L EQUIPEMENT DEMEURE A UNE TEMPERATURE DE 15 6 C 60 F OU P
16. INSTALLATION AND OPERATING INSTRUCTIONS MODEL 520 LOW VOLTAGE CONTROL CHAIR RELIANCE INTERNATIONAL SERIAL NUMBER For your future reference mark the serial number in the space provided QUALITY MANAGEMENT SYSTEM REGISTERED TO ISO 9001 2008 ISO 13485 2003 RELIANCE INTERNATIONAL MADE IN AMERICA Reliance Medical Products 3535 Kings Mills Road Mason Ohio 45040 2303 1 800 735 0357 e www reliance medical com TABLE OF CONTENTS IMPORTANT 4 1 12 u 5 TECHNICAL SPECIFICATIONS 6 2 INSTALLATION ee 7 2 1 Unpacking 7 IL AAA PP ne 7 2 2 Assembly 7 A 7 Power 7 3 OPERATION opone 8 CALE era 8 Raising amp Lowering the Chair Lift from the o MR seuss 8 3 2 Chair Top u uu MEE 8 Posistioning the Chair Back 8 3 3 Revolving Rotation 9 3 4 Armrest Movement 9 A 9 AR 9 4 LOCATING AND REPLACING FUSES 9 4 1 Fuse
17. LUS DURANT AU MOINS 8 HEURES AVANT DE L UTILISER AVERTISSEMENT L ENTREPOSAGE DE IN 520 2 INSTALLATION 2 1 Unpacking 2 1 1 Chair 2 1 1 1 Cut the shipping bands open the top of the shipping carton and remove all packing material and boxes that can be easily reached Remove 4 nuts and remove both base clamping boards 2 1 1 2 It is recommended that the skid be positioned as close as possible to the desired Chair location 2 1 1 3 Remove atleast two small shipping blocks stapled to the top of the skid The Chair can now be slid and or tipped from the skid onto the floor 2 1 1 4 Do not lift the Chair by the upper structure However the Chair may be tipped or slid into position by pushing or pulling on the upper structure 2 1 1 5 With the Chair in positon remove all remaining paper pads plastic tape strings etc 2 2 Assembly 2 2 1 Headrest 2 2 1 1 Remove the Headrest from its carton Remove seat upholstery by pulling the top away from Chair structure Attach Headrest to Chair frame using two 5 16 x 5 8 hex head cap screws supplied with Chair Replace seat upholstery Insert the two locating screws on seat frame into the two holes in bottom of seat upholstery Press back to frame so the hook and loop fabric fasteners engage IN 520 2 2 2 Power Receptacle 2 2 2 1 Locate the Footswitch assembly Chair Control Cable and the Power Cord Assembly Refer to figure 1 for receptacle location and a
18. R THAN AVERAGE PATIENTS AVERTISSANT LE CONTR LE FERME DU SOMMET DE PR SIDENCE DOIT TRE MIS JOUR PENDANT L EX CUTION TENDUE C EST PARTICULIEREMENT IMPORTANT AVEC PLUS LOURD OU LE CHALAND QUE LES PATIENTS MOYENS IN 520 RELEASE LEVER FIGURE 3 RELEASE LEVER 3 3 Revolving Rotation 3 3 1 The Chair upper structure may be revolved 350 with a builtin stop to prevent continuous rotation The lock for revolving is controlled by a hand lever with black knob located below the seat at the center and on either side Push the lever backward to release the lock and pull upward to apply the lock 3 4 Armrest Movement 3 4 1 The Chair Armrests may be raised to provide better access to the patient or to permit entrance to or exit from the Chair 3 4 2 The movements of both Armrest are identical and completely independent of each other 3 4 3 To raise the Armrest simply lift Armrest to the stop parallel to Chair back CAUTION This exam Chair is designed for use in a specific position called the Intended Use Position Prior to reclining a patient ensure the Chair Back is aligned with the Chair s power receptacle and that the Chair Swivel is locked The safe working load is reduced if the Chair is swiveled away from this Intended Use Position and may result in insufficient stability IN 520 PRECAUTION Cette chaise d examen est concue pour utilisation dans une position specifique
19. alcohol 9 Lighter fluid naptha Type 3 Cleaners Strong active solvent cleaners such as nail polish remover acetone water to be applied with a soft cloth Stain should be removed with less than six 6 rubs if Stain persists after six rubs contact manufacturer Dry area with another cloth rinse with clean water and dry CAUTION These solvents are highly flammable Exercise proper care in cleaning and notify personnel in area of danger Wear rubber gloves during all cleaning activity Use caution in cleaning around buttons stitching and wooden or other decorative trim since these solvents could seriously damage such areas inflammables Faites tres attention lors du nettoyage et avisez le personnel dans la zone de tout danger Portez des gants de caoutchouc durant toute activite de nettoyage Faites attention en nettoyant autour des boutons des coutures et autres finitions de bois ou decoratives puisque ces solvants pourraient endommager s rieusement ces endroits PR CAUTION Ces solvants sont extr mement Cleaning Painted Surfaces The painted metal surfaces are covered in durable powder coated paint which is resistant to scratching and scuffing It may be cleaned with a clean cloth dampened with mild soapy water or equivalent household product that uses spray application Recommended Infection Control Products The disinfectant cleaner products that we have tested and recommend for our upholstery
20. ans la chaise Avant d incliner la chaise assurez vous que le patient est assis dans la chaise et que la position du patient ne se d place pas vers une position extr me soit vers la t te soit vers le pied de la chaise puisque cela pourrait causer une stabilit insuffisante 10 3 5 Footrest 3 5 1 The Footrest may be retracted by lifting near its outer edge When retracted the Footrest stays in place 3 6 Headrest 3 6 1 Afixed non articulating Headrest is the only Headrest available on the 520 Chair This Headrest is ergonamically designed for patients of a wide range of heights 4 0 LOCATING AND REPLACING FUSES 4 4 op 10 5 790V 2 0008 1186 as marked CAUTION WARNING DISCONNECT EQUIPMENT FROM MAIN INPUT POWER BEFORE PROCEEDING WITH ELECTRICAL INSPECTIONS OR MAINTENANCE AVERTISSEMENT D CONNECTEZ L QUIPEMENT DE L ALIMENTATION LECTRIQUE PRINCIPALE AVANT DE PROC DER DES INSPECTIONS LECTRIQUES OU DE L ENTRETIEN fuses must be replaced with a fuse of the same size and rating Refer to the Wire Diagrams at the end of this Manual PRECAUTION Remplacez le s fusible s comme indiqu Tous les fusibles doivent tre remplac s par un fusible de la m me dimension et de la m me valeur Se r f rer aux sch mas de c blage la fin de ce manuel CAUTION Replace fuse s as marked All The Chair contain two fuses located insi
21. de the AC Input Module in the Base Assembly 4 1 Fuse Replacement AC Input Module 4 1 1 Unplug the power cord from the AC power Input Module Referring to Figure 4 locate tab With a tool similar to a small common screwdriver placed under tab pry Fuse Drawer out Remove the Fuse Drawer by pulling it out with your fingers 4 1 2 To remove fuses from Fuse Drawer tilt fuses in direction of arrows as shown in Figure 4 Examine the fuses replace as necessary Tab Place small bladed screwdriver Do AC INPUT MODULE FUSE DRAWER FIGURE 4 AC INPUT MODULE IN 520 TROUBLESHOOTING GUIDE PROBLEM PROBLEM CAUSE SOLUTION CHAIR WILL NOT OPERATE 1 POWER CORD NOT PLUGGED IN 1 CHECK ALL WIRING CONNECTIONS 2 NO AC POWER AT WALL RECEPTACLE 2 RESTORE OUTLET POWER 3 BLOWN LINE FUSE 3 REPLACE FUSE OUTLET POWER OK BUT NO 1 BLOWN LINE FUSE 1 REPLACE FUSE IS HEARD WHEN POWER 2 LOOSE WIRING IN BASE 2 CHECK ALL WIRING CONNECTIONS IS APPLIED 3 OTHER 3 CONTACT FACTORY FOOTSWITCH FUNCTIONS NOT OPERATING CHAIR BASE WILL NOT STAY UP CHAIR BASE WILL NOT LOWER CHAIR BASE WILL NOT RAISE PUMP MOTOR DOES NOT RUN CHAIR BASE WILL NOT RAISE PUMP MOTOR RUNS BASE STUTTERS
22. parts are needed contact the Reliance Distributor where you purchased this product or contact the Technical Service Department Medical Products Inc 3535 Kings Mills Road Mason Ohio 45040 2303 or call 800 735 0358 IN 520 FIGURE 5 520 CHAIR ASSEMBLY 40 1 11 12 MODEL AND SERIAL NUMBER PLATE 44 00 LOW 7 55 46 50 HIGH BASE TRAVEL 8 75 LOW i 11 25 HIGH 2 f Ss i 28 88 LOW NCA EL OUR 31 38 HIGH c 6 BASE TRAVEL cus 25 Jd 7 21 00 LOW 8 75 LOW B rue 4 23 50HIGH 11 25 HIGH 4 BASE TRAVEL 8 75 LOW 11 25 HIGH AS BASE 19 09 30 94 38 96 ITEM PART NO DESCRIPTION ITEM PART NO DESCRIPTION EBENEN Chair Top Assembly See Figure 6 2723973 Upholstered Seat Assembly 21 Chair Base Assembly See Figure 7 6 2346773 Upholstered Apron Assembly Headrest Assembly See Figure 9 2347373 Upholstered Armrest Assembly RH 2342203 8 2347473 Upholstered Armrest Assembly LH Please specify upholstery color when ordering To order complete Upholstery Set use P N 2349373 Upholstery Set 520 IN 520 I9 FIGURE 6 520 CHAIR TOP ASSEMBLY 34 4 CN 50 IN 520 16
23. pe of protection against electric shock EQUIPMENT energized from an external electrical power source CLASS EQUIPMENT he degree of protection against electric shock TYPE B EQUIPMENT he degree of protection against harmful ingress of water ORDINARY DEGREE he degree of safety of application in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE he mode of operation CONTINUOUS OPERATION WARNING TO PREVENT FIRE OR crc SHOCK HAZARD DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE AVERTISSEMENT POUR VITER UN rev OU UN RISQUE DE CHOC LECTRIQUE N EXPOSEZ PAS CET QUIPEMENT LA PLUIE OU L HUMIDIT TECHNICAL SPECIFICATIONS Rating for 120V Low Voltage Chair This equipment is rated Class Type B Model Equipment Low Voltage Chair olts Hertz Class CSA 22 2 NO 601 1 UL 60601 Rating for 230V Low Voltage Chair This equipment is rated Class Type B Model Amps amp Equipment Low Voltage Chair Vol Class a NO 601 1 UL 60601 ts Hertz IMPORTANT USER WARNINGS MUST NOT BE USED IN THE WARNING EXPLOSION HAZARD THIS PRESENCE OF FLAMMABLE ANESTHETICS CET EQUIPEMENT NE DOIT PAS ETRE UTILIS EN PRESENCE D ANESTH SIQUES INFLAMMABL
24. s special instructions or procedures which If not strictly observed could result in damage to or destruction of equipment PR CAUTION symbole de pr caution identifie des instructions ou proc dures sp ciales qui si elles ne sont pas strictement suivies pourraient causer un dommage ou la destruction de l quipement IN 520 Note indicates points of particular or f additional information 4 REMARQUE Remarque indique des points d int r t particulier ou des renseignements additionnels 1 3 Should your product not perform properly or if you have any questions concerning the use and care of any Reliance product contact the Reliance Distributor where you purchased this product or contact the Technical Service Department Reliance Medical Products Inc 3535 Kings Mills Road Mason Ohio 45040 2303 or call 800 735 0358 NOTE Always have the model number and serial number available before contacting Reliance or your authorized Reliance Distributor REMARQUE Ayez toujours le num ro de modele et le num ro de s rie port e de la main avant de contacter Reliance ou votre distributeur Reliance autoris CLASSIFIED BY CANADIAN STANDARDS ASSOCIATION WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601 1 According to Clause 5 in IEC 60601 1 sec 6 8 1 this unit is classified by the following he ty
25. ttach all cables Footswitch able Power Cord amp Fusedrawer Chair Control Cable a FIGURE 1 BASE 2 2 2 2 To disconnect power to Chair unplug Power Cord from Instrument Stand or from wall receptacle NOTE If this Chair is purchased in conjunction with f a Reliance Instrument Stand the Chair Control Cable supplied will provide proper operation Refer to the Instrument Stand Manual for connection to the Stand REMARQUE Si cette chaise est achet e avec un support instruments Reliance le cable de commande de la chaise fourni permettra un fonctionnement ad quat Se r f rer au manuel du support d instrument pour savoir comment faire la connexion au support 3 OPERATION CAUTION Caution should be taken to ensure there are no obstructions instruments trays tables impeding movement of the Chair PR CAUTION On devrait faire attention pour s assurer qu il n y a pas d obstructions instruments plateaux tables emp chant le mouvement de la chaise Each time main power is applied to the Chair the circuit board inside the Chair will respond with a one second beep The beep indicates the electronics are functioning properly 3 1 Chair Lift 3 1 1 Raising amp Lowering the Chair Lift from the Footswitch e For operation from the Footswitch Figure 2 depress the right side of the pedal to raise the Chair