1. MONTAJE Ss Regolazione orizzontale e fissaggio Horizontal adjustement unit and anchorage R glage orizontal et fixation Horizontale Einstellung Regulaci n horizontal y fijaci n Regolazione verticale o messa in bolla Vertical adjustement and unit leveling R glage vertical ou mise niveau Vertikale Einstellung Regulaci n vertical y nivelaci n MONTARE LA CREMAGLIERA MOUNT THE RACK MONTEZ LA CREMAILLERE MONTAGE DER ZAHNSTANGE MONTAR LA CREMALLERA Accoppiamento pignone cremagliera modulo 4 e Rack to pinion coupling module 4 AD Assemblage pignon cr mali re module 4 Zwischen Zahnstange und dem Antriebsritzel Ritzelmodul 4 Acoplamento pi on cremaliera m dulo 4 Allineamento cremagliera Rack alignment Alignement cr maill re Fluchtung der Zahnstange Alineaci n de la cremallera 7 MANOVRA MANUALE MANUAL MANOEUVRE MANOEUVRE MANUELLE MANUELLES MANOVRIEREN MANIOBRA MANUAL Prima di effettuare qualsiasi intervento sull impianto togliere l alimentazione elettrica Always disconnect the electricity before attempting any work on the system Coupez l arriv e de courant lectrique avant toute intervention sur l automatisme Vor jeglichen Eingriffen an der Anlage ist die Stromversorgung zu unterbrechen Antes de cualquier operaci n en la instalaci n cortar la alimentaci n el ctrica MONTAGGIO SLITTE FINECORSA
2. Apertura a DESTRA Opening on the RIGHT Ouverture DROITE e ffnen nach RECHTS Apertura a la DERECHA DISPOSIZIONE LAYOUT DISPOSITION DISPOSITION DISPOSICION Apertura a SINISTRA Opening on the LEFT Ouverture GAUCHE Offnen nach LINKS Apertura a la IZQUIERDA 3 NOTA CAVI CABLE NOTE CONNEXION CABLE BEMERKUNG ZU KABEL ANSCHL SSEN NOTA CABLES a Linea Monofase Single phase line Ligne monophas e Einphasenleitung L nea monof sica Fotocellula Trasmett Transmitter photocell Photocellule mettrice Senderfotozelle Fotoc lula transmisor Fotocellula Ricev Receiver photocell Photocellule r ceptrice Empf ngerfotozelle Fotoc lula receptor EE Blinkleuchte Indicador intermitente BASAMENTO BASE BASE BASIS BASE Battuta apertura Opening sensitive edge Capteur ouverture Anschlag beim Offnen Tope de abertura Fissare la piastra di base con tasselli ad espansione oppure annegare le zanche nel calcestruzzo Secure the base plate with expansion bolts or embed the fishtail clamps in concrete e Fixer la plaque de base l aide de chevilles expansion ou enfouir les agrafes dans le b ton Die Grundplatte mit D beln befestigen oder die Verankerungsklauen in Beton eingieBen e Fijar la placa de fundaci n con tornillos de expansi n o bien introducir las grapas de anclaje en el hormig n 5 MONTAGGIO ASSEMBLY MONTAGE MONTAGE
3. INSTALL THE LIMIT SWITCH SLIDES MONTAGE CHARIOTS MICRO INTERRUPTEURS MONTAGE SCHLITTEN ENDSCHALTER MONTAJE GUIAS FIN DE CARRERA COLLEGAMENTI ELETTRICI ELECTRICAL CONNECTIONS BRANCHEMENTS ELECTRIQUES ELEKTRISCHE ANSCHL SSE CONEXIONES EL CTRICAS Consultare il manuale d installazione e uso della centralina DEC SC Consult the DEC SC control unit s installation and operating manual Consulter le manuel d installation et d utilisation de la centrale DEC SC Die Installations und Bedienungsanleitungen der Steuereinheit DEC SC nachschlagen Consultar el manual de instalaci n y uso de la centralita DEC SC
4. O s r l no es responsable de dafios causados a personas animales o cosas debidos a aplicaciones que superen los l mites indicados en la ficha t cnica adjunta o debidos a utilizaci n diferente de aquella apra la cual el producto fue proyectado GENERALIDAD El motorreductor SMART 800 ha sido espec ficamente pensado para mover cancelas correderas de hasta 800 kg de peso en el respeto de las normativas europeas Es apto para un uso de tipo residencial r SCHEDA TECNICA TECHNICAL DATA SHEET FICHE TECHNIQUE TECHNISCHES BLATT FICHA TECNICA ALIMENTAZIONE POWER ALIMENTATION STROMVERSORGUNG ALIMENTACI N MOTORE MOTOR MOTEUR MOTOR MOTOR POTENZA ASSORBITA BSORBED POWER PUISSANCE ABSORB E LEISTUNGSAUFNAHME POTENCIAABSORBIDA VELOCITA SPEED VTESSE GESCHWINDIGKEIT VELOCIDAD COPPIA TORQUE COUPLE DREHMOMENT PAR MAXANTA 20um PESO eMAX LEAF WEIGHT POIDS MAXI VANTAIL MAX GEWMTCH TORFL GEL PESO M X HOJ A 800 g DEC SC CENTRALINA CONTROL UNIT CENTRALE STEUEREINHEIT CENTRALITA CONDIZIONI AMBIENTAL ENVIRONMENTAL CONDITIONS CONDITIONS AMBIANTES UIMGEBUNGSBEDINGUNGEN CONDICIONES AMBIENTALES GRADO DI PROTEZIONE PROTECTION LEVEL INDICE DE PROTECTION SCHUTZGRAD GRADO DE PROTECCI N 230vac 1074 5060 H gt 230vac 1400s PM 10 290w amp 5mnin 15 450 c IP 24 MEDIDAS DIMENSIONI D INGOMBRO OVERALL DIMENSIONS DIMENSIONS HORS TOUT ABMESSUNGEN
5. T 800 230V AUTOMAZIONE PER CANCELLI SCORREVOLI AUTOMATION FOR SLIDING GATES AUTOMATION POUR PORTES COULISSANTES AUTOMATION F R SCHIEBETORE AUTOMACI N PARA CANCELAS CORREDERAS INSTALLAZIONE USO E MANUTENZIONE ET ENTRETIEN amp INTRODUZIONE Il libretto di INSTALLAZIONE USO E MANUTENZIONE e destinato agli installatori agli utilizzatori ed agli operatori della manutenzione Leggere attentamente il libretto prima di installare il prodotto utilizzarlo e prima di eseguire manutenzione ordinaria o straordinaria Le operazioni che se non effettuate correttamente possono presentare rischi sono indicate con i simboli A A FOLGORAZIONE SCHIACCIAMENTO La O amp O s r l non e responsabile per danni arrecati a persone animali o cose dovuti ad applicazioni che superano limiti indicati nella scheda tecnica allegata o dall uso diverso da quello per cui il prodotto stato progettato GENERALITA Il motoriduttore SMART 800 stato progettato per automatizzare cancelli scorrevoli fino a 800 kg di peso nel rispetto delle normative europee E adatto ad un utilizzo di tipo residenziale amp INTRODUCTION The INSTALLATION USE AND MAINTENANCE handbook is for installers users and maintenance engineers Please read it carefully before installing the appliance before using it and before routine or extraordinary maintenance work Operations that if not carried out correctly can be risky are indicate
6. d with the following symbols CRUSHING ELECTROCUTION O amp O s r l is not liable for injury to people or animals or damage to things in the case of applications that exceed the limits specified on the enclosed technical data sheet or by a use different from what the appliance has been designed GENERAL The SMART 800 gear reducer is designed to automate sliding gates weighing up to 800 kg in compliance with European standards It is suitable for use in residential areas INSTALLATION USE AND MAINTENANCE e INSTALLATION GEBRAUCH UND WARTUNG C amp AVANT PROPOS Cette notice est destin e aux installateurs aux utilisateurs et aux techniciens charg s de l entretien Lisez attentivement cette notice avant d installer l automatisme de l utiliser et avant de proc der son entretien ordinaire ou extraordinaire Les op rations pr sentant des risques si elles ne sont pas effectu es correctement sont signal es avec les symboles ELECTROCUTION ECRASEMENT La soci t O amp O s r l d cline toute responsabilit en cas de d g ts des personnes animaux ou biens provoqu s par des applications d passant les limites pr vues dans la fiche technique jointe ou par un usage diff rent de celui pour lequel l automatisme a t concu GENERALITES Le motor ducteur SMART 800 a t concu pour l automation de portes coulissantes de 800 kg maximum dans le respect des normes europ ennes ll est adap
7. e L automatismo SMART 800 The SMART 800 automatism conforme ai requisiti imposti dalle direttive 2006 95 CEE bassa tensione e 2004 108 CEE compatibilit elettromagnetica collegamenti elettrici devono essere effettuati nel rispetto delle disposizioni legislative vigenti L installatore deve istruire l utilizzatore sul corretto funzionamento dell automatismo sulla manovra manuale d emergenza e sui possibili rischi durante il funzionamento Prima di effettuare qualsiasi intervento sull impianto togliere l alimentazione elettrica conforms to the requirements laid down by the EEC directives 2006 95 low voltage and 2004 108 electromagnetic compatibility All electrical connections must be done in compliance with current laws The installer must instruct the user on how to use the automatism correctly onthe manual emergency manoeuvre and on the possible risks during operation Always disconnect the electricity before attempting any work on the System L automatisme SMART 800 est conforme aux prescriptions des directives 2006 95 CEE basse tension et 2004 108 CEE compatibilit lectromagn tique Les branchements lectriques doivent tre conformes la l gislation en vigueur en la mati re L installateur doit informer l utilisateur sur le fonctionnement del automatisme surla manoeuvre manuelle d arr t d urgence et sur les risques li s au fonctionnement Coupez l arriv e de courant lect
8. hout any friction Check operation of the limit switch and relative slides Check that the control unit and safety devices are all in proper working order Visually check that the gate fixing brackets and existing structure are in good condition Check that motor force in the closing phase does not exceed the limits indicated in the current standards cancello le staffe di fissaggio e la Visually check that the gate fixing struttura esistente siano in buone condizioni oso brackets and existing structure are in good condition L entretien doit tre effectu seulement par un personnel qualifi Contr ler l alignement porte motor ducteur et la distance 1 2 mm entre gorge du pignon et cr te de la cr maillere Nettoyer les guides de d pla cement des roues de la porte graisser l gerement le pignon du motor ducteur et la cr maill re S assurer manuellement que le d placement de la porte est r gulier et s effectue sans frottement Contr ler le fonctionnement de la fin de course et des glissi res correspondantes Contr ler le fonctionnement de la centrale et des dispositifs de s curit Contr lez si la force du moteur en phase de fermeture ne d passe pas les limites pr vues par la l gislation en vigueur S assurer visuellement que la porte les brides de fixation et la structure existante sont en bon tat Die Wartung hat ausschlie lich durchFachpersonal zu erfolgen Die F
9. ineaci n entre la cancela y el motorreductor y la distancia 1 2 mm entre el canal del pi n y la cresta de la cremallera e Limpiar las gu as de deslizamiento de las ruedas de la cancela engrasar ligeramente el pi n del motorre ductor y la cremallera Comprobar manualmente que la cancela se deslice libremente y sin rozamientos Comprobar que el fin de carrera y las correspondientes correderas funcionen correctamente Comprobar que la centralita y los dispositivos de seguridad funcionen correctamente Kontrollieren dass die Motorkraft Comprobarquelafuerzadelmotor en w hrend des Schliessvorgangs nicht die von den geltenden Geset zen vorgeschriebenen Grenzwerte berschreitet Per Sichtkontrolle berpr fen dass das Tor die Verankerungsb gel und die vorhandene Struktur in gutem Zustand sind O amp O s rl Via Europa 2 42015 CORREGGIO R E Italy tel 39 0 522 740111 fax 39 0 522 631290 http www oeo it email oeo 2oeo it Societ soggetta ad attivit di direzione e coordinamento di SOMFY S A Company subject to management and coordination activities by SOMFY S A fase de cierre no supere los l mites de las normas vigentes Comprobar visualmente que la cancela las bridas de sujeci n y la estructura existente est n en buen estado Cod 035337 Rev 000 del 30 07 10 SINGERT CzmRM T eun RATIFICADOS Reg n 308 UNI EN ESO 3001 2008 SMAR
10. luchtung Tor Getriebemotor und den Abstand 1 2 mm zwischen Ritzelkehle und Zahnstangenspitze berpr fen Die F hrungsschienen der Torr der reinigen und den Getriebemotor ritzel und die Zahnstange leicht schmieren Von Hand berpr fen dass das Tor korrekt und ohne Reibung auf den F hrungsschienen gleitet Die Funktionst chtigkeit der En dschalter und der entsprechenden Sehlitten berpr fen Die Funktionst chtigkeit der Steu ereinheit und der Sicherheitsvor richtungen berpr fen SEGURIDAD GENERAL El automatismo SMART 800 cumple los requisitos impuestos por las directivas 2006 95 CEE bajatensi n y 2004 108 CEE compatibilidad electromagn tica as conexiones el ctricas deben efectuarse cumpliendo las disposiciones de ley vigentes El instalador debe instruir al usuario sobre el funcionamiento correcto del automatismo maniobra manual de emergencia y posibles riesgos durante el funcionamiento Antes de cualquier operaci n en la instalaci n cortar la alimentaci n el ctrica USO Seguir tajantemente las indicaciones presentadas en la hoja adjunta ADVERTENCIAS GENERALES PARA LA SEGURIDAD En caso de maniobra manual seguir las indicaciones del punto 7 Consultar el manual de instalaci n y uso de la centralita DEC SC MANTENIMIENTO ORDINARIO CADA 6 MESES El mantenimiento debe ser efectuado s lo por personal cualificado Comprobar la al
11. nleitungen sind strikt zu befolgen Beim manuellen Man vrieren sind die unter Punkt 7 beschriebenen Anleitungen zu beachten Die Installations und Bedienungsan leitungen der Steuereinheit DEC SC nachschlagen MANUTENZIONE ORDINARIA OGNI SEI MESI ROUTINE MAINTENANCE EVERY 6 MONTHS ENTRETIEN ORDINAIRE TOUS LES 6 MOIS ORDENTLICHE WARTUNG ALLE MONATE La manutenzione deve essere eseguita solo da personale qualificato Controllare l allineamento cancello motoriduttore e la distanza 1 2 mm tra gola del pignone e cresta della cremagliera Pulire le guide di scorrimento delle ruote del cancello ingrassare leggeremente il pignone del moto riduttore e la cremagliera Verificare manualmente che lo scorrimento del cancello sia rego lare e privo di attriti Controllare il funzionamento del finecorsa e delle relative slitte Controllare il corretto funzionamen to della centralina e dei dispositivi di sicurezza Controllare che la forza del motore in fase di chiusura non superi i li miti indicati nelle normative vigenti Controllare visivamente che il Maintenance must be carried out by qualified personnel only Check alignment of the gate gear reducer and the distance 1 2 mm between the grooved pinion and the crest of the rack Clean the guides along which the gate runs lightly grease the gear reducer s pinion and the rack Manually check that the gate runs along the guides smoothly wit
12. rique avant toute intervention sur l automatisme Der Automatismus SMART 800 entspricht den Vorgaben der Richtlinien 2006 95 EWG Niederspannung und 2004 108 EWG elektromagnetische Vertr glichkeit Beim Anschluss an die Stromversorgung sind die geltenden Gesetze zu befolgen Der Installateur hat den Anwender bez glich des korrekten Betriebs des Automatismus der manuellen Bedienung bei St rungen und Notf llen sowie bez glich der m glichen Gefahren w hrend des Betriebs zu unterrichten Vor jeglichen Eingriffen an der Anlage ist die Stromversorgung zu unterbrechen Seguire tassativamente le indicazioni contenute nel foglio allegato AVVERTENZE GENERALI PER LA SICUREZZA In caso di manovra manuale seguire le indicazioni descritte al punto 7 Consultareil manualed installazione e uso della centralina DEC SC e lt is essential to follow the instructions given in the enclosed GENERAL INSTRUCTIONS FOR SAFETY sheet Inthe case of amanual manoeuvre follow the indications described in point 7 Consult the DEC SC control unit s installation and operating manual Suivez scrupuleusement les prescriptions report es sur la feuille jointe REGLES GENERALES DE SECURITE En cas de manoeuvre manuelle suivez les indications d crites au paragraphe 7 Consulter le manuel d installation et d utilisation de la centrale DEC SC Die in dem beigestellten Blatt ALLGEMEINE SICHERHEITSVOR SCHRIFTEN enthaltenen A
13. t une utilisation de type r sidentiel LIT NEN FREDEXES CE POSE MODE D EMPLOI ET INSTALACI N USO Y MANTENIMIENTO C A EINLEITUNG Das INSTALLATIONS BETRIEBS UND WARTUNGSHANDBUCH ist f r die Installateure Anwender und Wartungsfachm nner bestimmt Das Handbuch ist vor der Installation des Produkts sowie vor der ordentlichen und auBerordentlichen Wartung sorgf ltig zu lesen Wenn die durch folgende Symbole gekennzeichneten Eingriffe nicht korrekt durchgef hrt werden kann es zu Gefahrsituationen kommen A A STROMSCHLAG QUETSCHUNG Die Firma O amp O s r l haftet nicht f r Perso nen Tier oder Sachsch den die auf eine unsachgem e Anwendung des Produkts sowie auf das berschreiten der im tech nischen Blatt angegebenen Grenzwerte zur ckzuf hren sind ALLGEMEINES Der Getriebemotor SMART 800 wurde f r die Automation von Schiebetoren mit einem Gewicht bis zu 800 kg entwickelt erf llt die EU Normen und ist f r den Einsatz in Wohnanlagen geeignet 4 INTRODUCCI N El folleto de INSTALACI N USO Y MANTENIMIENTO se destina a instaladores usuarios y operadores de mantenimiento Leer detenidamente el folleto antes de instalar el producto utilizarlo y efectuar el mantenimiento ordinario o extraordinario Las operaciones que si no son efectuadas correctamente pueden conllevar riesgos vienen indicadas con los s mbolos ELECTROCUCI N APLASTAMIENTO La O amp

Download Pdf Manuals

image

Related Search

Related Contents

Graco Husky 205 User's Manual  User Manual  NetSC520 Demonstration Board User`s Manual  Sanyo PLC-XU111K User's Manual  Netgear GS108T User's Manual  HP ProBook 450  HP Universal Messenger  Sony XS-V1332 Marketing Specifications  MFI 9 Melt Flow Indexer User Manual  Samsung SGH-X810 User Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.