Home

Installation Manual

image

Contents

1. Dependiendo del modelo la bomba tiene un punto de descarga roscado de 1 1 4 plg o 1 1 2 plg para que se pueda conectar al tubo de descarga Vea la Figura A para consultar el tama o de la descarga de su modelo espec fico No reduzca el tama o de la descarga a menos de 1 1 4 pulg ya que el hacerlo afectar el flujo y el funcionamiento de la bomba Se recomienda una tuber a de PVC 40 aunque se pueden usar mangueras flexibles de forma provisional MODELO TAMA O DE LA DESCARGA 101 1 1 4 plg Serie 230 1 1 2 plg Serie 240 1 1 2 plg Serie 450 1 1 2 plg Figura A Conecte la tuber a o la manguera de descarga a la bomba APRIETE LA CONEXI N S LO CON LA MANO Apretar de m s puede provocar que la caja de la bomba se agriete Copyright 2012 Liberty Pumps Inc Todos los derechos reservados 3 5 Instale una uni n u otro medio para separar la l nea de descarga justo encima del nivel del piso en caso de que sea necesario desmontar la bomba Encima de la uni n a o en su lugar se recomienda instalar una v lvula de retenci n para evitar el contraflujo del agua despu s de cada ciclo de bombeo 6 Si se usa una v lvula de retenci n hay que perforar un orificio para la esclusa de aire de 3 mm 1 8 plg en la tuber a de descarga justo encima de la salida de la descarga de la bomba para prevenir que se formen esclusas de aire en la bomba V lvula de retenci n ME LL o uni n MUS LI Perfore el orificio para
2. Cette pompe n cessite un circuit de d rivation d di correctement prot g par un fusible et mis la terre S assurer que la tension et l intensit du courant lectrique de la source d alimentation lectrique sont suffisantes pour r pondre aux exigences de la pompe telles qu indiqu es sur la plaque signal tique La prise lectrique doit se trouver la port e du cordon d alimentation de la pompe et au moins 1 2 m 4 pi au dessus du niveau du plancher pour minimiser les dangers possibles pouvant tre caus s par une inondation L installation doit tre faite en respectant le Code national de l lectricit le Uniform Plumbing Code le Code international de plomberie ainsi que tous les codes locaux et r glements en vigueur Les pompes d ass chement et de syst me d gout traitent souvent des mati res pouvant causer des maladies Porter des v tements protecteurs ad quats pour manipuler une pompe ou de la tuyauterie ayant d j servi Ne jamais p n trer dans le r servoir de pompage apr s qu il ait servi Les gouts et effluents peuvent mettre des gaz toxiques Demeurer l cart des ouvertures d aspiration et d vacuation Afin de pr venir les blessures ne jamais ins rer les doigts dans la pompe alors qu elle est branch e NE PAS utiliser ce produit pour pomper des liquides inflammables ou corrosifs NE PAS utiliser ce produit pour les installations o le contact humain avec les liquides pomp s est fr quent
3. El fabricante no tendr obligaci n alguna bajo esta garant a si el producto no ha sido instalado correctamente si ha sido desmontado modificado abusado o forzado si el cord n el ctrico se ha cortado da ado o empalmado si se redujo el tama o de la descarga de la bomba si la bomba se us con agua m s caliente de la temperatura nominal o agua con arena cal cemento grava u otros elementos abrasivos si se utilizaron productos qu micos para bombas o hidrocarburos si un motor no sumergible fue sometido a un exceso de humedad o si se retir la etiqueta con el n mero de serie y de c digo Liberty Pumps Inc no se hace responsable de p rdidas da os o gastos que resulten por la instalaci n o uso de sus productos o por da os emergentes incluidos los costos de desmontar reinstalar o transportar la unidad No se ofrece ninguna otra garant a expresa Todas las garant as impl citas incluidas las de comerciabilidad y adecuaci n para un prop sito determinado est n limitadas a un plazo de tres a os a partir de la fecha de compra Esta garant a representa el nico remedio del comprador y siempre que se permita se excluye toda responsabilidad por da os emergentes y fortuitos bajo toda otra garant a OCopyright 2012 Liberty Pumps Inc Todos los derechos reservados 7 libefty Pumps 7000 Apple Tree Avenue Bergen NY 14416 Tel fono 800 543 2550 Fax 585 494 1839 www libertypumps com Copyright 2012 Liberty P
4. IMPORTANT Avant Pinstallation noter les num ros de mod le de s rie et de code qui figurent sur la plaque signal tique pour ventuellement s y r f rer MOD LE S RIE CODE DATE D INSTALLATION Copyright 2012 Liberty Pumps Inc Tous droits r serv s Renseignements g n raux tous les modeles Lire attentivement les directives avant d effectuer l installation Chaque pompe de marque Liberty est test e individuellement en usine pour assurer son bon fonctionnement Le fait de suivre ces directives la lettre liminera les risques de probl mes de fonctionnement et assurera des ann es de fonctionnement sans soucis Danger d lectrocution Toujours d brancher la pompe de l alimentation lectrique avant de la manipuler ou d y effectuer des r glages Les raccords lectriques et le c blage pour l installation de la pompe ne devraient tre effectu s que par des professionnels qualifi s Cette pompe est fournie avec un conducteur de mise la terre et une fiche de branchement de type mise la terre Afin de r duire les dangers d lectrocution s assurer que celle ci est raccord e seulement une prise de correctement mise la terre Toujours porter des bottes de caoutchouc lorsqu il y a de l eau sur le plancher et qu il est n cessaire de d brancher la pompe NE PAS d vier les fils de mise la terre ou retirer la broche de mise la terre des fiches de branchement NE PAS utiliser de rallonge
5. envisager l ajout d une pompe de secours comme une pompe d ass chement Liberty SJ10 ainsi que d une alarme comme le mod le Liberty ALM 2 pour les installations o une panne de la pompe risque de causer des dommages mat riels Lorsqu une alarme est utilis e elle doit tre raccord e un circuit lectrique distinct Copyright 2012 Liberty Pumps Inc Tous droits r serv s 4 Fig 1 Piggyback plug installation 9 Les mod les 243 233 et 453 sont munis d un interrupteur flotteur fix la pompe en usine Ce mod le est muni de deux cordons lun reli l interrupteur flotteur et l autre au moteur de la pompe Le cordon de l interrupteur est muni d un connecteur en s rie siamois permettant de brancher le cordon de la pompe moteur sur son dos voir fig droite Ce syst me a pour but de permettre le fonctionnement manuel temporaire de la pompe si d sir NORMAL TEMPORAIRE 10 Mod les manuels submersibles on peut mettre en marche les mod les manuels sans interrupteur en les branchant directement dans une prise lectrique approuv e Afin de pr venir l usure excessive des joints d tanch it et la surchauffe les pompes ne doivent pas fonctionner vide pendant de longues p riodes Un minimum de 11 4 cm 4 po d eau est recommand Si les pompes manuelles doivent fonctionner avec un dispositif de commande facultatif suivre les directives d installation fournies avec le dispositif de com
6. jamming The Brick sold by Liberty Pumps as part 4445000 is a pre molded stable platform designed to fit your submersible pump It raises the pump 2 5 off the bottom of the pit reducing the potential for jamming from rocks and debris Contact your local distributor to order Remove all debris from the bottom of the sump pit before installation of the pump A sump pit cover is suggested for safety and to prevent foreign objects from entering the pit Installation of Pump All Models Removal of Old Pump IIA SNIE Disconnect pump from power source before handling Separate the discharge pipe at either the check valve or at the union If neither a check valve nor a union is part of the existing discharge pipe cut the pipe with a hacksaw and remove the pump A union or check valve will need to be installed at this cut NOTE Pedestal pump model 101 requires assembly of the float rod and guide Snap the plastic guide into position with its pin located in the center hole on the column of the pump Insert the threaded end of the float rod down through the hole in the guide and attach the float ball to the threaded end Remove the upper rubber stop and insert the rod through the hole in the switch arm Replace the upper rubber stop at least Y from the end of the rod Set the new pump in place making sure the float switch has adequate clearance and will not hang up on the pit wall The float must be free to move throughout it
7. piscines fontaines etc NE JAMAIS disposer de mat riaux comme du solvant peinture ou d autres produits chimiques en les vidant dans l avaloir car ils peuvent attaquer chimiquement et endommager les composants de la pompe causant ventuellement son mauvais fonctionnement ou sa d faillance A AVERTISSEMENT Ne pas utiliser ces pompes dans de l eau dont la temp rature est sup rieure 60 C 140 F NE PAS utiliser de pompes avec de la boue du sable du ciment du p trole ou d autres produits chimiques NE PAS modifier les pompes de quelque mani re que ce soit NE PAS soulever ou transporter la pompe par son cordon lectrique NE PAS retirer les tiquettes de la pompe ou des cordons Si la pompe est install e durant la construction avant que l alimentation lectrique ne soit disponible il est important de la garder l abri afin d emp cher que de l eau ne p n tre par l extr mit du cordon lectrique etc Outils n cessaires cl tuyau tournevis ordinaire scie m taux pour remplacer ou retirer le tuyau rigide existant Copyright 2012 Liberty Pumps Inc Tous droits r serv s 2 Puisard tous les modeles 1 On recommande l utilisation d un puisard dont le diam tre est d au moins 35 6 cm 14 po Dans le cas de pompes submersibles munies d un flotteur vertical mod les 237 et 247 un puisard d un diam tre d au moins 25 cm 10 po est acceptable Un diam tre sup rieur est recom
8. Motor or switch may be defective Consult factory PUMP SPRAYS WATER FROM SIDE OF HOUSING 1 This is normal due to factory drilled air bleed hole and is not cause for concern Maintenance 1 Submersible Models Submersible pump models have sealed permanently lubricated bearings and require no additional lubrication 2 Pump should be checked frequently for debris and or build up which may interfere with pump or float switch operation The float must be able to move freely through its complete travel without any restrictions Pour enough water into the sump to activate the pump periodically at least every 3 months when not normally in use to verify proper function 3 Pedestal Models Pedestal sump pumps have open exposed motors Take precautions to make sure the motor does not get wet from dripping pipes etc Pour an ounce of 20 or 30 weight oil into the hole near the top of the pedestal column every 6 months A label next to the hole designates where to add the oil See figure C Pour enough water into the sump pit to activate the pump periodically at least every 3 months when not normally in use Check periodically to make sure the pit is free from accumulated debris rocks or other objects that may potentially jam the pump 00 gigi T I T Oil Hole Figure C Copyright 2012 Liberty Pumps Inc All rights reserved 3 Year Limited Warranty Liberty Pumps Inc warrant
9. arriba 7 Conecte extensiones de tuber a adicionales seg n sea necesario para dirigir la descarga al punto deseado La descarga debe ser lo m s corto posible con un n mero de giros m nimo Verifique todas las conexiones 8 Para mayor protecci n considere agregar una bomba de respaldo como la SJ10 SumpJet de Liberty adem s de un sistema de alarma como el ALM 2 de Liberty en aplicaciones donde la p rdida de funcionamiento de la bomba pueda resultar en da os a la propiedad Si se utiliza una alarma se deber conectar a un circuito el ctrico separado Copyright 2012 Liberty Pumps Inc Todos los derechos reservados 4 10 4 Fig 1 Piggyback plug installation Los modelos 243 233 y 453 vienen equipados con un interruptor de flotador montado en la bomba misma Este modelo cuenta con dos cables uno al interruptor de flotador y el otro al motor El cable del interruptor cuenta con un interruptor en serie o cascada en el que se puede conectar el cable del motor vea la figura a la derecha Esto permite la operaci n manual de la bomba durante un tiempo limitado NO NORMAL TEMPORAL Para modelos manuales sumergibles Los modelos manuales sin interruptor se pueden operar conect ndolos directamente a un tomacorriente el ctrico aprobado Para evitar el desgaste excesivo de los sellos debido al sobrecalentamiento no se deber hacer funcionar las bombas en seco por periodos prolongados Se recomienda un nive
10. conveniente instalar una cubierta para el sumidero por motivos de seguridad y para evitar la entrada de objetos for neos Instalaci n de la bomba para todos los modelos 1 4 Retiro de la bomba antigua PIN EU GIN Desconecte la bomba del suministro el ctrico antes de manejarla Separe el tubo de descarga a nivel de la v lvula de retenci n o de la uni n Si ni la v lvula de retenci n ni la uni n son parte del tubo de descarga existente corte el tubo con una sierra para metales y quite la bomba Se necesitar instalar una uni n o una v lvula de retenci n a nivel de este corte NOTA El modelo 101 de la bomba del pedestal requiere armar el flotador la barra y la gu a Encaje a presi n la gu a pl stica en su posici n con el pasador que tiene en el orificio central en la columna de la bomba Inserte el extremo roscado de la barra del flotador hacia abajo por el orificio de la gu a y fije la bola del flotador en el extremo roscado Retire el tope superior de hule e inserte la barra por el orificio del brazo del interruptor Vuelva a colocar el tope superior de hule por lo menos a 12 mm 2 plg del extremo de la barra Coloque la nueva bomba en su lugar asegur ndose de que el interruptor de flotador tenga suficiente espacio para moverse sin que toque la pared del sumidero El flotador deber poder moverse libremente a lo largo de todo su recorrido y no hacer contacto con el cuerpo de la bomba tubos u otros objetos
11. est obstruida o si el rotor est atascado Extraiga la malla de la bomba y limpie la entrada y el rotor seg n se necesite El impulsor de la bomba puede estar atascado Verifique que no haya materiales extra os como escombros piedras etc que puedan evitar que el impulsor gire Recordatorio Antes de revisar el rea de la entrada y el rotor compruebe que la bomba est desconectada de la fuente de alimentaci n A BOMBA FUNCIONA Y EXTRAE AGUA PERO NO SE APAGA El flotador est atorado en la posici n ON Verifique para asegurarse de que el flotador pueda subir y bajar libremente sin obstrucciones El interruptor puede estar defectuoso Consulte al fabricante Copyright 2012 Liberty Pumps Inc Todos los derechos reservados 5 LA BOMBA FUNCIONA PERO EXTRAE MUY POCA AGUA 1 N Re La elevaci n vertical se aproxima a la m xima capacidad de elevaci n de la bomba Consulte la tabla de elevaciones m ximas de arriba La entrada de la bomba se encuentra parcialmente bloqueada Verifique para asegurarse de que la entrada est libre de residuos La l nea de descarga est parcialmente bloqueada Verifique que no haya bloqueos en la l nea La v lvula de retenci n no se abre completamente Verifique que la v lvula de retenci n no est defectuosa invertida ni bloqueada EL DISYUNTOR SE DISPARA O EL FUSIBLE SE FUNDE CUANDO LA BOMBA SE ENCIENDE 1 2 3 4 El tama o del fusible o del disyuntor es demasiado
12. si le produit n a pas t correctement install s il a t d mont modifi soumis a un usage abusif ou endommag si le cordon lectrique a t coup endommag ou ligatur si la taille du tuyau d vacuation de la pompe a t r duite si la pompe a t utilis e pour pomper de l eau d une temp rature sup rieure aux recommandations ci dessus ou de l eau contenant du sable de la chaux du ciment du gravier ou autres mati res abrasives si le produit a t utilis pour pomper des produits chimiques ou des hydrocarbures si un moteur non submersible a t expos a de l humidit excessive ou si l tiquette portant le num ro de s rie de mod le et de code a t retir e Liberty Pumps Inc ne pourra tre tenue responsable des pertes dommages frais attribuables a l installation ou l utilisation de ses produits ni pour les dommages accessoires ou cons cutifs y compris les co ts de retrait de r installation ou de transport Il n y a aucune autre garantie expresse Toute garantie implicite y compris celles de qualit marchande et d aptitude a une fin particuli re est limit e a trois ans a partir de la date d achat Cette garantie contient le recours exclusif de l acheteur et exclut lorsque permis par la loi toute responsabilit pour dommages cons cutifs ou accessoires en vertu de toutes autres garanties Copyright 2012 Liberty Pumps Inc Tous droits r serv s 7 Libefty Pumps 7000 a
13. If an alarm is used it must be connected to a separate electrical circuit Copyright 2012 Liberty Pumps Inc All rights reserved Fig 1 Piggyback plug installation 9 Models 243 233 and 453 come factory equipped with a float switch mounted to the pump This model has two cords one to the float switch and the other to the pump motor The switch cord has a series piggyback plug enabling the pump motor cord to be plugged into the back of it see Fig at right The purpose of this design is to allow temporary manual operation of the pump if desired NORMAL OPERATION 10 For manual submersible models Manual switchless models may be operated by directly plugging into an approved electrical outlet To prevent excessive seal wear and overheating pumps should not be run dry for extended periods of time A minimum 4 1 2 water level is recommended If manual models are to be used with an optional control device follow the instructions provided with that control and make power connections per those instructions Set the turn off level at 4 1 2 or greater Do not remove float rods from VMF models for manual use as switch damage will result 4 Trouble Shooting A WARNING Always disconnect the pump from power source before handling This guide is designed to help identify reasons for potential operating problems It is not a service guide Dismantling of pump voids warranty Servicing of pump other than simple
14. Installation Manual 7108000H For Pedestal and Submersible Sump Pumps Do not throw away or lose this manual Keep it with the installation and refer to it often Pedestal Model 1 3 hp 101 Cast Iron Submersible Models 1 4 hp 240 Series Cast Iron 240 Manual 241 Wide Angle Float 243 Wide Angle Float w Series Plug 247 Vertical Float Submersible Models 1 3 hp 230 Series Poly Aluminum 230 Manual 231 Wide Angle Float 233 Wide Angle Float w series plug 237 Vertical Float Submersible Models 1 2 hp 450 Series Poly Aluminum 450 Manual 451 Wide Angle Float 453 Wide Angle Float w series plug 457 Vertical Float IMPORTANT Prior to installation record Model Serial Number and Code Number from pump nameplate for future reference MODEL SERIAL CODE INSTALLATION DATE Copyright 2012 Liberty Pumps Inc All rights reserved General Information All Models Before Installation read the following instructions carefully Each Liberty pump is individually factory tested to assure proper performance By closely following these instructions potential operating problems should be eliminated providing years of trouble free service A WARNING Risk of electric shock Always disconnect the pump from the power source before handling or making adjustments The electrical connections and wiring for a pump installation should only be made by qualified personnel This pump is supplied wit
15. a pompe il sera n cessaire d installer un clapet antiretour ou un raccord union l endroit de cette coupure REMARQUE Le model 101 de pompe de pi destal exige le montage du flotteur de la tige et du guide Enclencher le guide de plastique en place avec la goupille situ e dans l orifice central de la colonne de la pompe Ins rer l extr mit filet e de la tige du flotteur dans l orifice du guide et fixer le ballon du flotteur l extr mit filet e Retirer le butoir de caoutchouc sup rieur et ins rer la tige dans l orifice du levier de l interrupteur Replacer le butoir de caoutchouc au moins 13 mm de l extr mit de la tide 2 Mettre la nouvelle pompe en place en s assurant que l interrupteur ait suffisamment de d gagement et ne risque pas de s accrocher la paroi lat rale du puisard Le flotteur doit pouvoir se d placer librement sur tout son parcours sans contact avec le corps de la pompe la tuyauterie ou tout autre objet 3 Selon le mod le un raccord d vacuation filet de 1 po ou 1 po est fourni sur la pompe pour raccorder le tuyau d vacuation Voir la figure A pour conna tre la dimension de la sortie de chaque mod le particulier Ne pas installer de tuyau d vacuation d un diam tre inf rieur 1 po car cela risque de nuire au d bit et au rendement de la pompe Il est recommand d utiliser du tuyau de PVC de nomenclature 40 cependant on peut utiliser un ensemble de tuyau d vacuation souple p
16. a pompe est raccord e a une rallonge ou le c blage est inad quat Demander a un lectricien de v rifier le c blage Le moteur ou l interrupteur peut tre d fectueux Consulter le fabricant DE L EAU EST VAPORISEE A PARTIR DU COTE DU BOITIER DE LA POMPE 1 C est normal car un orifice d vacuation de l air y a t perc en usine Il n y a pas lieu de s inqui ter Mod les submersibles ces mod les de pompes sont munis de roulements lubrification permanente qui ne n cessitent aucun graissage suppl mentaire Il est important de v rifier la pompe r guli rement car la pr sence de d bris ou de d p ts peut nuire au fonctionnement de la pompe ou de l interrupteur a flotteur Le flotteur doit tre en mesure de se d placer librement sur tout son parcours sans restriction Verser suffisamment d eau dans le puisard pour activer la pompe de temps en temps au moins tous les 3 mois afin d en v rifier le fonctionnement lorsqu elle ne fonctionne pas r guli rement Mod les sur colonne le moteur des pompes d ass chement sur colonne est ouvert et expos Prendre les pr cautions n cessaires pour s assurer que le moteur n est pas expos de l eau qui d go te de tuyaux etc Verser 29 ml 1 oz d huile de calibre 20 ou 30 dans l orifice pr s du sommet de la colonne tous les 6 mois Une tiquette c t de l orifice indique o ajouter l huile Voir figure C Verser suffisamment d eau dans le puisard pour activer
17. a que indica d nde agregar el aceite Vea la Figura C Vierta suficiente agua en el sumidero para activar la bomba peri dicamente por lo menos una vez cada tres meses cuando no se utilice la bomba de manera frecuente Revise el sumidero peri dicamente para cerciorarse de que no haya escombros rocas u otros objetos acumulados que podr an llegar a atascar la bomba Orificio para aceite Figura C OCopyright 2012 Liberty Pumps Inc Todos los derechos reservados 6 Garant a limitada de 3 a os Liberty Pumps Inc garantiza que las bombas que fabrica est n libres de defectos de materiales y mano de obra por un per odo de 3 a os a partir de la fecha de compra La fecha de compra se determinar con el recibo de compra fechado que incluya el modelo y el n mero de serie de la bomba Este recibo deber acompa ar a la bomba si la fecha de devoluci n ocurre m s de 3 a os despu s de la fecha de fabricaci n c digo CODE indicada en la placa de la unidad Las obligaciones del fabricante bajo esta garant a se limitar n a la reparaci n o el reemplazo de las piezas que el fabricante determine que son defectuosas siempre que la pieza o el ensamblaje se devuelva con el porte pagado al fabricante o a uno de sus centros de servicio autorizados y que no se evidencie ninguna de las siguientes caracter sticas lo que supondr a la anulaci n de la garant a
18. cleaning of pump inlet or impeller should be referred to the factory or its authorized service centers NOTE The manufacturer assumes no responsibility for damage or injury due to disassembly in the field PUMP DOES NOT RUN OR HUM Line circuit breaker may be off tripped or loose Have certified electrician check fuse or breaker Water level in pit may be too low to activate switch Add more water to pit Plug on power cord may not be making contact in receptacle Check security and connection If the pump is using the series piggyback cord plug the plugs may not be connected tightly together Float may be obstructed Make sure float is free and not interfering with the pit wall or other obstruction If all symptoms check OK the motor winding may be open Consult factory OARONA PUMP RUNS OR HUMS BUT DOES NOT DELIVER WATER 1 Check valve may be installed backwards or is defective Check to make sure it is installed properly and flapper in valve is free to move 2 Discharge line may be blocked or frozen Check to see if line passes through cold areas or is blocked 3 Pump may be air locked Make sure that an anti airlock hole was drilled in discharge pipe Submersible models are factory equipped with a bleed hole already in base of pump Ensure that this hole is not plugged 4 Vertical lift may be beyond pumps capability See chart below for your pump s maximum lift capability NOTE At the pump s maximum lift there will be no fl
19. e de corps trangers comme des d bris de construction des pierres etc susceptibles d emp cher le rotor de tourner Rappel toujours d brancher la pompe de sa source d alimentation lectrique avant d en v rifier l entr e ou le rotor LA POMPE TOURNE ET POMPE L EAU MAIS ELLE NE S TEINT PAS 1 Le flotteur est bloqu en position de marche S assurer que le flotteur bouge librement de bas en haut Copyright 2012 Liberty Pumps Inc Tous droits r serv s 5 J 2 L interrupteur peut tre d fectueux Consulter le fabricant LA POMPE TOURNE MAIS NE POMPE QUE TRES PEU D EAU 1 ON aad La charge ascensionnelle est pr s de la limite maximum de la pompe Consulter le tableau ci dessus pour connaitre la charge ascensionnelle maximum de la pompe ci dessus L entr e de la pompe est partiellement obstru e V rifier pour s assurer que l entr e ne contient pas de d bris La canalisation d vacuation est partiellement obstru e V rifier la canalisation d vacuation pour s assurer qu il n y a pas de blocage Le clapet antiretour ne s ouvre pas compl tement S assurer que le clapet antiretour n est pas d fectueux l envers ou obstru LE DISJONCTEUR SE D CLENCHE OU LE FUSIBLE SAUTE LORSQUE LA POMPE SE MET EN MARCHE 1 2 3 4 La puissance du disjoncteur ou du fusible n est pas suffisante D autres appareils nergivores sont raccord s au m me circuit La pompe devrait avoir son circuit d di L
20. enaje y de alcantarillado a menudo manejan materiales capaces de provocar enfermedades Use ropa protectora adecuada cuando trabaje en una bomba o una tuber a usada Nunca ingrese a una cubeta de bomba despu s que haya sido usada Los sistemas de efluentes y de alcantarillado pueden emitir diferentes tipos de gases t xicos Mant ngase alejado de la entrada de succi n y de la salida de descargas Para evitar lesiones nunca inserte los dedos en la bomba mientras se encuentre conectada NO use este producto para l quidos inflamables o corrosivos NO use este producto en aplicaciones en las que el contacto humano con el fluido bombeado sea com n por ejemplo piscinas fuentes etc NUNCA deseche por el drenaje materiales tales como solvente para pintura u otros qu micos ya que pueden llegar a atacar y da ar los componentes de la bomba y potencialmente causar que el equipo no funcione bien o deje de funcionar Ah PRECAUCI N NO utilice las bombas en agua con temperatura superior a los 140 F 60 C NO utilice las bombas con lodo arena cemento aceite o qu micos NO modifique la bomba de ninguna manera NO levante ni transporte la bomba por medio del cable el ctrico NO retire ninguna etiqueta de la bomba o cables Si la bomba se instala durante una construcci n antes de que haya energ a el ctrica disponible se deber proteger de la intemperie para evitar que el agua ingrese a trav s del enchufe etc Herramientas necesa
21. h a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle Always wear rubber boots when water is on the floor and you must unplug the pump DO NOT bypass grounding wires or remove ground prong from attachment plugs DO NOT use an extension cord This pump requires a separate properly fused and grounded branch circuit Make sure the power source is properly sized for the voltage and amperage requirements of the pump as noted on the nameplate The electrical outlet shall be within the length limitations of the pump power cord and at least 4 feet above floor level to minimize possible hazards from flood conditions The installation must be in accordance with the National Electric Code Uniform Plumbing Code International Plumbing Code as well as all applicable local codes and ordinances Sump and sewage pumps often handle materials which could cause illness or disease Wear adequate protective clothing when working on a used pump or piping Never enter a pump basin after it has been used Sewage and effluent can emit several gases which are poisonous Keep clear of suction and discharge openings To prevent injury never insert fingers into pump while it is plugged in DO NOT use this product for flammable or corrosive liquid DO NOT use this product in applications where human contact with the pumped fluid is common s
22. l m nimo de 11 4 cm 4 1 2 plg de agua Si los modelos manuales se utilizan con un dispositivo de control opcional siga las instrucciones incluidas con dicho control y haga las conexiones el ctricas de acuerdo con dichas instrucciones Configure el nivel de apagado a 11 4 cm 4 1 2 plg o m s No quite las varillas flotar a partir de modelos VMF para uso manual como da os interruptor resultado Diagn stico de problemas PIXMEUANN Desconecte la bomba siempre que vaya a moverla o a realizar alg n ajuste Esta gu a est di ise ada para ayudar a identificar las razones de posibles problemas de operaci n Esto no es una gu a de servicio Desmantelar la bomba anular la garant a Cualquier otro tipo de servicio a la bomba aparte de la simple limpieza d e la entrada o del impulsor deber referirse al fabricante o a sus centros de servicio autorizados NOTA El fabricante no asume ninguna responsabilidad por da os o lesiones resultantes por desarmar la bomba en el campo LA BOMBA NO FUNCIONA NI ZUMBA 1 on amp D D L 1 2 3 L 1 2 El disyuntor de l nea puede estar desactivado haberse activado o est suelto Pida a un electricista certificado que revise el fusible o el disyuntor El nivel del agua en el sumidero puede estar demasiado bajo para activar el interruptor Agregue m s agua al sumidero El enchufe del cable el ctrico puede no estar haciendo contacto en el tomacorriente Verifiq
23. la esclusa de aire de 3 mm 1 8 plg a El rociado de agua es normal fam OOOO Bomba sumergible Figura B Bomba de pedestal Mi bomba tiene una esclusa de aire Qu es un orificio para la esclusa de aire Esclusa de aire es un t rmino que se usa para describir el caso en que se retiene aire en el rea de la voluta o el rotor de una bomba y no puede eliminarse debido a que la columna de agua est por encima de la v lvula de retenci n de la l nea de descarga Cuando se llena de agua el sumidero y se quiere arrancar la bomba el rotor gira dentro de esa bolsa de aire y no puede cebarse Cuando eso sucede el s ntoma consiste en que la bomba funciona pero no bombea nada Un orificio para esclusa de aire permite eliminar ese aire retenido para que la bomba pueda cebarse y comenzar a bombear Liberty incluye un orificio para esclusa integral en la caja de la voluta de las bombas sumergibles Cuando la bomba funciona es normal que dicho orificio roc e agua La purga del aire podr a tardar de algunos segundos hasta m s de un minuto una vez que arranca la bomba Para agilizar o facilitar la purga de aire en caso de haber esclusa de aire se recomienda agregar un orificio de 3 mm 1 8 plg en la tuber a de descarga El di metro de dicho orificio no debe superar los 3 mm 1 8 plg y tiene que perforarse a baja altura en la tuber a justo encima de la conexi n roscada a la descarga de la bomba Vea la Figura B m s
24. la pompe de temps en temps au moins tous les 3 mois lorsqu elle ne fonctionne pas r guli rement V rifier r guli rement pour s assurer que le puisard ne renferme pas d accumulation de d bris cailloux ou autres objets qui risquent de bloquer la pompe Orifice pour l huile Ct In ODO E DDD Figure C Copyright 2012 Liberty Pumps Inc Tous droits r serv s 6 Garantie limit e de 3 ans Liberty Pumps Inc garantit que les pompes sortant de son usine sont exemptes de tout d faut de mat riau et de fabrication pour une p riode de 3 ans a partir de la date d achat La date d achat sera tablie par une facture d achat dat e indiquant les num ros de mod le et de s rie de la pompe La pompe retourn e doit tre accompagn e de la facture d achat dat e si la date de retour se situe a plus de 3 ans du num ro de CODE date de fabrication indiqu sur la plaque signal tique de la pompe L obligation de garantie du fabricant se limite a la r paration ou au remplacement de toute pi ce jug e d fectueuse par le fabricant condition que la pi ce ou l appareil soient retourn franco de port au fabricant ou a son centre d entretien autoris et a condition qu il n y ait aucune preuve que les crit res suivants annulant la garantie sont en cause Le fabricant ne peut en aucun cas tre tenu responsable selon les dispositions de cette garantie
25. mand car il permet de plus longs cycles de fonctionnement de la pompe et r duit le fonctionnement de l interrupteur Le puisard devrait avoir une profondeur d au moins 30 5 cm 12 po au dessus de la surface o repose la pompe 2 Si le puits n est pas d j ferm au bas fournir une base solide et au niveau en brique ou en b ton NE PAS placer la pompe directement sur de la terre du gravier ou des d bris susceptibles de causer une usure pr matur e du rotor et m me de le bloquer The Brick vendu par Liberty Pumps pi ce n 4445000 est une plateforme pr moul e stable congue pour l installation de votre pompe submersible Elle soul ve la pompe de 6 35 cm 2 5 po du fonds du puisard r duisant ainsi les risques d obstruction caus e par les cailloux et les d bris Communiquer avec le distributeur local pour commander Retirer tous les d bris du fond du puisard avant l installation de la pompe On sugg re l installation d un couvercle de puisard pour plus de s curit et emp cher que des corps trangers tombent dans le puits Installation de la pompe tous les mod les 1 Retrait de l ancienne pompe D brancher la pompe de sa source d alimentation lectrique avant d en effectuer la manipulation S parer le tuyau d vacuation vis vis du clapet antiretour ou du raccord union Si le tuyau d vacuation en place ne comprend ni clapet antiretour ni raccord union couper le tuyau avec une scie m taux et retirer l
26. mande et faire les raccordements selon ce qui est recommand R gler le niveau d arr t 11 4 cm 4 po d eau ou plus Ne pas retirer des tiges flottent partir de mod les VMF pour une utilisation manuelle car les dommages commutateur r sultat 4 D pannage Toujours d brancher la pompe de sa source d alimentation lectrique avant de la manipuler Ce guide sert aider identifier les causes de probl mes de fonctionnement ventuels Ce n est pas un guide d entretien Le d montage de la pompe annulera la garantie L entretien de la pompe pour effectuer des travaux autres que d en nettoyer l entr e ou le rotor doit tre confi au fabricant ou ses centres d entretien autoris s REMARQUE Liberty Pumps Inc n est pas responsable des dommages ou blessures r sultant d un d montage sur le terrain LA POMPE NE FONCTIONNE PAS ET NE GRONDE PAS Le disjoncteur est ferm saut ou desserr Demander un lectricien agr de v rifier le fusible ou le disjoncteur Le niveau de l eau du puisard est trop bas pour activer l interrupteur Ajouter de l eau dans le puisard Le contact ne se fait peut tre pas entre le cordon d alimentation et la prise V rifier la s curit et les raccords Si la pompe fonctionne avec connecteur en s rie siamois les fiches ne sont peut tre pas bien branch es Le flotteur est peut tre bloqu S assurer que le flotteur bouge librement et ne touche pas la paroi du puisard ni t
27. ock hole Air lock is a term used to describe when air gets trapped in the volute impeller area of a pump and cannot escape due to the water column above the check valve on the discharge line When the pit fills with water and the pump is called to activate the impeller spins in this pocket of air and cannot prime My pump runs but does not pump anything is the symptom when this happens An anti airlock hole allows this trapped air to escape allowing the pump to prime and start pumping Liberty provides an integral anti airlock hole in the volute housing of submersible pumps Water spray from this hole is normal while the pump is in operation Bleeding off the air could take from several seconds to more than a minute once the pump starts To speed or assist with air bleed in the event of airlock the addition of a 1 8 hole in the discharge pipe is recommended This hole should be no more than 1 8 diameter and drilled low on the pipe just above the threaded connection to the pump discharge See Figure B above 7 Connect additional pipe as necessary to direct the discharge to the desired location Discharge should be kept as short as possible with a minimum number of turns Check all connections for security 8 For added protection consider the addition of a back up pump such as Liberty s SJ10 SumpJet as well as an alarm such as Liberty s ALM 2 in applications where loss of pump function could result in property damage
28. olute du rotor d une pompe et ne peut s chapper en raison du volume d eau pr sent au dessus du clapet antiretour de la canalisation d vacuation Lorsque le puisard est rempli d eau et que la pompe est activ e le rotor tourne dans cette poche d air et ne peut s amorcer La pompe fonctionne mais ne pompe rien du tout est le sympt me de ce ph nom ne Un orifice d vacuation permet cet air emprisonn de s chapper permettant l amor age de la pompe qui se mettra pomper Liberty fournit un orifice d vacuation int gr dans le bo tier de la volute des pompes submersibles Une l g re vaporisation d eau de cet orifice est normale lorsque la pompe fonctionne La purge de l air peut prendre de plusieurs secondes une minute une fois que la pompe se met en marche Pour acc l rer ou favoriser l expulsion de l air en cas de poche d air l ajout d un orifice d vacuation de 3 mm 1 8 po dans la conduite d vacuation est recommand Le diam tre de cet orifice ne doit pas d passer 3 mm 1 8 po et il doit tre perc au bas du tuyau juste au dessus du raccordement filet de la sortie de la pompe Voir la figure 1 B ci dessus 7 Raccorder au besoin un tuyau suppl mentaire pour diriger l vacuation l endroit d sir La conduite d vacuation devrait tre la plus courte possible et comporter un nombre minimum de virages V rifier l tanch it de tous les joints des raccordements 8 Pour plus de protection
29. our les installations temporaires MOD LE DIMENSION DE LA SORTIE 101 1 po S rie 230 1 po S rie 240 1 po S rie 450 172 po Figure A 4 Raccorder le tuyau d vacuation temporaire ou permanent la sortie filet e de la pompe RESSERRER A LA MAIN SEULEMENT Trop serrer peut endommager le bo tier de la pompe Copyright 2012 Liberty Pumps Inc Tous droits r serv s 3 5 Installer un raccord union ou autre dispositif permettant de s parer la canalisation d vacuation juste au dessus du plancher pour faciliter le retrait de la pompe si n cessaire On recommande l installation d un clapet antiretour apr s le raccord union ou sa place afin de pr venir le refoulement du liquide apr s chaque cycle de la pompe 6 Lorsqu on utilise un clapet antiretour il est recommand de percer un orifice d vacuation de 3 mm 1 8 po dans le tuyau d vacuation juste au dessus de la sortie de la pompe afin de pr venir la formation de poches d air Clapet antiretour ea o raccord union Rs gt vire Percer un orifice d vacuation de C LT h 3 mm Unel gere e vaporisation d eau est normale 5 Ma zs A AAIE OI OKOKO KO i gt Pompe submersible Figure B Pompe sur colonne La pompe est elle bloqu e par une poche d air Qu est ce qu un orifice d vacuation Une poche d air est un terme servant d crire ce qui se produit lorsque de l air est coinc dans la zone de la v
30. out autre obstacle Si toutes les v rifications de sympt mes sont conformes le bobinage du moteur peut tre ouvert Consulter le fabricant LA POMPE TOURNE OU GRONDE MAIS NE POMPE PAS D EAU 1 Le clapet antiretour est peut tre install l envers ou d fectueux V rifier pour s assurer qu elle est bien install e et que le clapet de la soupape bouge librement 2 La canalisation d vacuation peut tre bloqu e ou gel e V rifier si la canalisation d vacuation traverse des zones froides ou si elle est bloqu e 3 La pompe est peut tre bloqu e par une poche d air S assurer qu un orifice d vacuation a t perc dans la conduite d vacuation Les pompes submersibles sont munies en usine d un orifice d vacuation de lair situ la base de la pompe S assurer que cet orifice n est pas bouch 4 La charge ascensionnelle d passe peut tre la capacit de la pompe Consulter le tableau ci dessous pour conna tre la charge ascensionnelle maximum de la pompe REMARQUE lorsque la charge ascensionnelle maximum est atteinte il n y a plus de d bit MOD LE HAUTEUR MAXIMUM 101 5 2 m 17 pi PAN D S rie 230 6 4 m 21 pi S rie 240 6 1 m 20 pi S rie 450 10 4 m 34 pi 5 V rifier si le filtre d aspiration de la pompe est bouch ou le rotor est bloqu Retirer le filtre d aspiration de la pompe et nettoyer l entr e et le rotor au besoin 6 Le rotor de la pompe peut tre bloqu V rifier la pr senc
31. ow MODEL MAX LIFT 101 17 230 Series 21 240 Series 20 450 Series 34 5 Check to see if inlet screen of pump is plugged or the impeller is jammed Remove the pump screen and clean inlet and impeller as needed 6 Pump Impeller may be jammed Check for foreign material such as construction debris stones etc that might be preventing the impeller from rotating Reminder Make sure pump is disconnected from power source before checking inlet and impeller area PUMP RUNS AND REMOVES WATER BUT DOES NOT SHUT OFF 1 Float is stuck in the on position Check to make sure the float is free to move up and down without obstruction 2 Switch may be defective Consult factory Copyright 2012 Liberty Pumps Inc All rights reserved 5 PUMP RUNS BUT DELIVERS VERY LITTLE WATER 1 Vertical lift is approaching the pump s maximum lift capability Refer to the above maximum lift chart above 2 Pump s inlet is partially blocked Check to make sure the inlet is clear of debris 3 Discharge line is partially blocked Check line for blockage 4 Check valve is not opening all the way Check for defective reversed or blocked check valve CIRCUIT BREAKER TRIPS OR FUSE BLOWS WHEN PUMP STARTS 1 Fuse or breaker size is too small 2 Other major appliances are on the same circuit Pump should be on its own circuit 3 Pump is connected to an extension cord or wiring is inadequate Have an electrician check for proper wiring 4
32. peque o Hay otros electrodom sticos conectados al mismo circuito La bomba deber estar conectada a un circuito exclusivo La bomba est conectada a una extensi n el ctrica o el cableado es inadecuado Haga que un electricista verifique el cableado correcto El motor o el interruptor podr a estar defectuoso Consulte al fabricante LA BOMBA ROC A AGUA POR EL LADO DE LA CARCASA 1 Eso es normal debido al orificio de purga instalado de f brica y no debe ser motivo de preocupaci n Mantenimiento Modelos sumergibles Los modelos de bombas poseen cojinetes permanentemente lubricados y no necesitan lubricaci n adicional La bomba deber ser revisada a menudo para detectar escombros y o acumulaciones que puedan interferir con la operaci n de la bomba o del interruptor de flotador El flotador debe ser capaz de moverse libremente a lo largo de todo su recorrido sin restricci n alguna Para asegurar el funcionamiento adecuado vierta suficiente agua en el sumidero para activar la bomba peri dicamente por lo menos una vez cada tres meses cuando no se utilice la bomba de manera frecuente Modelos de pedestal Las bombas de sumidero de pedestal tienen motores abiertos y expuestos Tome precauciones para que el motor no se moje a causa de tuber as que gotean etc Vierta 30 cc 1 oz fl de aceite tipo 20W o 30W dentro del orificio cerca de la parte superior de la columna del pedestal cada 6 meses Junto al orificio hay una etiquet
33. rias Llave para tubos Desarmador normal Sierra para metales para reemplazar o quitar los tubos r gidos existentes Copyright 2012 Liberty Pumps Inc Todos los derechos reservados 2 2 Y Sumidero de agua Todos los modelos No es recomendable que el sumidero de agua tenga un di metro menor de 14 pulg 35 5 cm En el caso de bombas sumergibles equipadas con flotador vertical modelos 237 y 247 un di metro m nimo de 25 40 cm 10 plg es aceptable Es preferible que el di metro sea m s grande ya que de esta manera los ciclos de bombeo podr n ser m s largos y se reducir el n mero de veces que el interruptor tiene que entrar en funcionamiento La profundidad del sumidero debe tener por lo menos 30 5 cm 12 plg por encima de la superficie sobre la que se apoya la bomba Si el sumidero no tiene un fondo cerrado instale uno r gido y nivelado con hormig n armado o ladrillos NO instale la bomba directamente sobre tierra grava o escombros ya que el rotor se puede desgastar en exceso y atascarse The Brick vendida por Liberty Pumps como pieza No 4445000 es una plataforma estable premoldeada dise ada para encajar en su bomba sumergible La plataforma eleva la bomba 6 cm 2 5 plg sobre el fondo del sumidero lo cual reduce la posibilidad de atascamiento por rocas o escombros Para pedir el producto contacte a su distribuidor local Antes de instalar la bomba quite todo escombro del fondo del sumidero Es
34. s resulting from installation or use of its products or for consequential damages including costs of removal reinstallation or transportation There is no other express warranty All implied warranties including those of merchantability and fitness for a particular purpose are limited to three years from the date of purchase This Warranty contains the exclusive remedy of the purchaser and where permitted liability for consequential or incidental damages under any and all warranties are excluded Copyright 2012 Liberty Pumps Inc All rights reserved AN 2 libefty Pumps a 7000 Apple Tree Avenue Bergen NY 14416 Phone 800 543 2550 Fax 585 494 1839 www libertypumps com Copyright 2012 Liberty Pumps Inc All rights reserved 7108000H Ne pas jeter ni perdre ce manuel Conserver a proximit de l installation et consulter souvent Modele sur colonne 1 3 hp 101 Fonte Modeles submersibles 1 4 hp s S rie 240 Fonte 240 Manuelle 241 Flotteur grand angle 243 Flotteur grand angle et connecteur en s rie 247 Flotteur vertical Mod les submersibles 1 3 hp S rie 230 Poly aluminium 230 Manuelle 231 Flotteur grand angle 233 Flotteur grand angle et connecteur en s rie 237 Flotteur vertical Mod les submersibles 1 2 hp S rie 450 Poly aluminium 450 Manuelle 451 Flotteur grand angle 453 Flotteur grand angle et connecteur en s rie 457 Flotteur vertical
35. s that pumps of its manufacture are free from all factory defects in material and workmanship for a period of 3 years from the date of purchase The date of purchase shall be determined by a dated sales receipt noting the model and serial number of the pump The dated sales receipt must accompany the returned pump if the date of return is more than 3 years from the CODE date of manufacture number noted on the pump nameplate The manufacturer s obligation under this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer to be defective provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service center and provided that none of the following warranty voiding characteristics are evident The manufacturer shall not be liable under this Warranty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduced in size if the pump has been used in water temperatures above the advertised rating or water containing sand lime cement gravel or other abrasives if the product has been used to pump chemicals or hydrocarbons if a non submersible motor has been subjected to excessive moisture or if the label bearing the serial model and code number has been removed Liberty Pumps Inc shall not be liable for any loss damage or expense
36. s travel and not contacting the pump body piping or other objects Depending on the model either a 1 1 4 or 1 1 2 threaded discharge is provided on the pump for connection to the discharge pipe See Figure A for the discharge size of your specific model Do not reduce the discharge size to less than 1 1 4 as this will affect pump flow and performance Schedule 40 PVC pipe is recommended however flexible discharge hose kits may be used for temporary installations MODEL DISCHARGE SIZE 101 1 1 4 230 Series 1 1 2 240 Series 1 1 2 450 Series 1 1 2 Figure A Connect the pipe or the discharge hose to the discharge of the pump HAND TIGHTEN ONLY Overtightening may cause the pump housing to crack Copyright 2012 Liberty Pumps Inc All rights reserved 5 Install a union or other means of separating the discharge pipe just above the floor to facilitate removal of the pump if necessary A check valve is recommended just above or in place of the union to prevent the backflow of water after each pump cycle 6 If a check valve is used a 1 8 anti airlock hole should be drilled in the discharge pipe just above the pump s discharge outlet to prevent pump airlock pl Check Valve or Union MUS FT Drill 1 8 anti airlock hole pe y4 Water spray is normal Be Mira ma TOOWOOU gt Submersible Pump Figure B Pedestal Pump Is my pump air locked What is an anti airl
37. siguen estas instrucciones al pie de la letra se eliminar la posibilidad de problemas potenciales de funcionamiento proporcionando muchos a os de servicio satisfactorio ADVERTENCIA Riesgo de descarga el ctrica Desconecte la bomba siempre que vaya a moverla o a realizar alg n ajuste S lo personal calificado podr encargarse de instalar las conexiones y cables el ctricos necesarios para montar la bomba Esta unidad viene con un conector a tierra y un enchufe con conexi n a tierra Para evitar descargas el ctricas conecte la bomba a un tomacorriente a tierra debidamente Cuando haya agua en el piso y deba desenchufar la bomba siempre use botas de hule NO derive los cables de puesta a tierra ni retire las espigas a tierra de los enchufes NO use cables de extensi n Con esta bomba hay que utilizar un circuito derivado independiente debidamente conectado a tierra y con fusibles La fuente de alimentaci n tendr que tener suficiente capacidad para cumplir los requisitos de voltaje y amperaje indicados en la placa de la bomba El tomacorriente deber encontrarse al alcance del cable de alimentaci n de la bomba y a 1 2 metros como m nimo por encima del piso para evitar problemas en caso de inundaci n Se deber instalar la unidad seg n las disposiciones del C digo el ctrico nacional NEC y los C digos de plomer a de Estados Unidos adem s de todos los c digos y regulaciones locales que correspondan Las bombas de dr
38. uch as swimming pools fountains etc NEVER dispose of materials such as paint thinner or other chemicals down drains as they can chemically attack and damage pump components potentially causing product malfunction or failure CAUTION DO NOT use pumps in water over 140 F 60 C DO NOT use pumps in mud sand cement oil or chemicals DO NOT modify the pump in any way DO NOT lift or carry pump by power cord DO NOT remove any tags from pump or cords If pump is installed during construction before power is available it must be protected from the environment to prevent water from entering through the cord plug end etc Tools Required Pipe wrench Regular screw driver Hacksaw For replacement or removal of existing rigid piping Copyright 2012 Liberty Pumps Inc All rights reserved 2 2 Sump Pit All Models 1 4 A sump pit not less than 14 in diameter is recommended On submersible pumps equipped with the vertical float models 237 and 247 a minimum 10 diameter pit is acceptable A larger diameter pit is preferred as it allows for longer pump cycling and reduced switch cycling The depth of the pit should be at least 12 above the surface that the pump is resting on If the pit is not already enclosed on the bottom provide a hard level bottom of bricks or concrete DO NOT place the pump directly on earth gravel or debris since this can cause excessive wear of the impeller and possible
39. ue la seguridad y la conexi n Si la bomba usa un enchufe de cable en cascada los enchufes no se deber n conectar apretadamente El flotador puede estar obstruido Aseg rese de que el flotador pueda moverse libremente y que no est interfiriendo con la pared del sumidero u otro obst culo Si todos los s ntomas est n bien el devanado del motor puede estar abierto Consulte con el fabricante A BOMBA FUNCIONA O ZUMBA PERO NO EXTRAE AGUA La v lvula de retenci n puede estar instalada al rev s o est defectuosa Verifique la v lvula para asegurarse de que est instalada de manera adecuada y que los tapones puedan moverse libremente La l nea de descarga puede estar bloqueada o congelada Compruebe si la l nea pasa a trav s de zonas fr as o si est bloqueada La bomba puede tener una esclusa de aire Compruebe que se haya perforado un orificio para esclusa de aire en la tuber a de descarga Los modelos sumergibles vienen equipados de f brica con una purga de aire en la base de la bomba Verifique que dicho orificio no est obstruido La elevaci n vertical puede estar m s all de la capacidad de la bomba Vea la tabla de abajo para identificar la m xima capacidad de elevaci n de su bomba NOTA No habr flujo al nivel m ximo de elevaci n de la bomba MODELO M X ELEVACI N 101 5 18 m 17 pies Serie 230 6 40 m 21 pies Serie 240 6 10 m 20 pies Serie 450 10 36 m 34 pies Verifique si la entrada de la bomba
40. umps Inc Todos los derechos reservados
41. venue Apple Tree Bergen NY 14416 T l phone 800 543 2550 T l copieur 585 494 1839 www libertypumps com Copyright 2012 Liberty Pumps Inc Tous droits r serv s Manual de instalaci n 7108000H Para bombas de drenaje de pedestal y sumergibles No tire ni pierda este manual Mant ngalo junto a la instalaci n y cons ltelo a menudo Modelo de pedestal 1 3 HP 101 Hierro fundido Modelos sumergibles 1 4 HP Serie 240 Hierro fundido 240 Manual 241 Flotador de ngulo ancho 243 Flotador de ngulo ancho con tap n en serie 247 Flotador vertical Modelos sumergibles 1 3 HP Serie 230 Polialuminio 230 Manual 231 Flotador de ngulo ancho 233 Flotador de ngulo ancho con tap n en serie 237 Flotador vertical Modelos sumergibles 1 2 HP Serie 450 Polialuminio 450 Manual 451 Flotador de ngulo ancho 453 Flotador de ngulo ancho con tap n en serie 457 Flotador vertical IMPORTANTE Apunte el modelo el n mero de serie y el c digo que aparecen en la placa de la bomba antes de instalarla para que le sirvan de referencia en el futuro MODELO SERIE C DIGO FECHA DE INSTALACI N OCopyright 2012 Liberty Pumps Inc Todos los derechos reservados Informaci n general para todos los modelos Lea con atenci n estas instrucciones antes de instalar la bomba Todas las bombas de Liberty se someten a pruebas en f brica para garantizar un funcionamiento adecuado Si se

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SMART CAMERA ST1000 Benutzerhandbuch  Kenroy Home 32603ORB Instructions / Assembly  www.pac-audio.com  Pioneer Car Fascia Double DIN kit for Fiat Panda  SC-min/SC-1/SC-4 Indicator Manual Programming  電動式リフトカタログ  

Copyright © All rights reserved.
Failed to retrieve file