Home

未命名 -1 - aebath.com

image

Contents

1. plies with standards in your area Inspect unit carefully to ensure there are no damages or defects If you find a defect contact your distributor If damage has occured during transport contact your carrier Make sure you have received all the parts required to install the unit tools are not included Make sure the structure is level and square Before proceeding with the installation make sure the structures dimensions complie with the adjustment range of the product Mild dishwashing liquid will keep the surfaces bright and clean Rinse well and dry with a clean cloth Caution Powder detergent and liquid abrasive cleaners may damage surfaces Do not allow the surface to come into contact with cor rosive products such as acetone nail polish remover dry cleaning solution lacquer thinner gasoline etc Any cleaning product should be tested on a unconspi cuous surface before a complete cleaning Read the cleaning product data sheet to ensure it will not damage the surfaces to be clean INFORMATIONS INFORMATIONS Avant de commencer les travaux assurez vous de lire attentivement les instructions de montage Consultez le code du b timent de votre r gion afin de vous assurer que votre installation respecte les normes en vigueur Lors de la r ception inspecter le produit afin de v rifier que l ensemble des pi ces est en bonne condition Si un probl me survient signalez le imm diatement votre distri
2. installation termin e appliquer un filet de silicone la jonction ext rieure de la porte de douche et du seuil de la base ainsi qu la jonction des montants muraux et des murs Attendre au moins 24 heures avant d utiliser la douche afin de laisser le silicone s cher N appliquez pas de silicone sur la face INTERIEURE de la porte de douche L application l int rieur de la porte pourait causer des FUITES D EAUX 10 A amp E 9181 Boivin LaSalle Qu bec Canada H8R 2E8 Bath amp Shower Bain et Douche Tel 514 367 1741 ext 373 1 800 667 9506 ext 373 Toll Free Sans frais Fax 514 363 4753 service aebath com Web www aebath com A amp E Shower and Baths inc hereafter A amp E offers the following express limited warranty on each of its pro ducts This warranty extends only to the original owner end user for personal household use A amp E warrants his products to be free from defects in workmanship and ma terials under normal use and service for a period of one 1 year from the original date of purchase by the owner end user Any product reported to the authorized dealer or to A amp E as being defective within the warranty period will be repaired or replaced with a product of equal value at the option of A amp E This warranty is not transferable to a subsequent owner Neither the distributor authorize A amp E dealer nor or any other person has been authorized to make any af
3. De plus tracer le contour de la base sur le plancher Percer les trous de vissage sur le rebord de la base vis vis des montants de bois Veuillez utiliser un foret du m me diam tre que les vis pour cette tape Par la suite l aide d un foret du m me dia m tre que la t te de vis fraiser les trous de vissage BASE INSTALLATION INSTALLATION DE LA BASE Remove the base and install the drain onto the shower base following the sequence shown lt Strainer Cr pine Shower Base Base de douche A bed of mortar must be applied underneath the S tray of the shower base Apply a sufficient amount Rubber Washer 7 Rondelie de caoutchouc to support the base when it will be leveled and fixed We recommend that you place a plastic film lt Slip ring Rondelle de glissement over top and under the mortar This will ease the removal of the base if required in the future lt Nut crou Retirer la base et installer le drain en placant les pi ces dans l ordre montr Un lit de mortier doit soutenir la cuve de votre base de douche D poser suffisamment de mortier afin que votre base de douche soit bien supporter une fois la mise niveau et la fixation de la douche effec tu e Nous recommandons d envelopper le mortier avec une pellicule de plastique Ceci facilitera l enl vement de la base ult rieurement si requis 5 a E Q o 5 zi 5 gt 5 c S Mort
4. O Qty Description NO Qty Description 1 2 Capuchon du montant mural chrome 17 1 Porte clair Chanel cap extrusion Clear Door 2 Cheville murale 18 1 Panneau de retour joint magn tique Wall anchor Return panel magnetic gasket Jambage mural chrome Poign chrome Ch Il jamb 19 1 rome wal Jam Chrome handle 4 Vis 1 5 8 tete plate 20 2 Kit de joint pour porte et panneau fixe 1 5 8 flat head screw Gasket kit for door and fix panel 5 Joint de serrage 21 4 Jointde bas de porte Squeeze gasket Bottom door gasket 6 Panneau fixe clair 22A 1 Ancrage chrome d anti eclaboussure de panneau fixe droit Clear fixed panel Chrome Fix pannel bracket for backsplash right P Ecrou de barre pour paneau fixe Ancrage chrome d anti eclaboussure de panneau fixe droit 7 8 Bar nut for fixed panel 22B 1 Chrome Fix pannel bracket for backsplash left 9 Capuchon de barre de roulement 23 4 Seuil anti claboussure chrome Cap for chrome rolling bar Chrome back spash threshold 108 Amortisseur de roulette G 2 Ancrage chrome 90 pour anti claboussure Roller bumper L 90 Chrome bracket for back splash right Amortisseur de roulette D Ancrage chrome 90 pour anti claboussure 108 Roller bumper R 24B 1 90 Chrome bracket for back splash left Cache vis pour barre Panneau clair de retour 11 12 Screw cap for bar 25 1 Clear Return pannel Bar de roulement chrome Outil pour joint de serrage 13 Chrome rolling bar 26 1 Squeeze gasket tool Kit de roulette chrome Support d installation p
5. PS 2 QD Utility Knife Couteau lame r tractable Level Niveau 020 3 5 Lead Pencil Crayon mine de plomb Screwdriver Tournevis Measuring Tape Ruban a mesurer Set square Equerre Silicone Silicone mildew resistant r sistant la moisissure NA Trowel Truelle Caulking Gun Pistolet de calfeutrage Page 3 PARTS DIAGRAM SCH MA DES PIECES 18 457mm Dimensions are for reference only Validate dimensions with the pro B duct prior to installation 36 914mm Les dimensions sont a titre de reference seule ment Valider les di mensions avec le produit avant de proc der 24 i i l installation goomm CE 2 3mm 48 4 6 1219mm 3 5 116mm 90mm 1 DESCRIPTION Shower Base Base de douche Page4 PREPARATION PR PARATION If a protective film is present on the base re move it In order to protect your shower base during the installation cut a piece of the cardboard box to fit into the base Si votre base est recouverte d une pellicule de plas tique veuillez la retirer Afin de prot ger votre base lors de l installation d couper une pi ce de carton afin de couvrir le fond de la base Plastic film Pellicule de plastique Cardboard Carton Shower base Base de douche Before installing the shower base make sure that the w
6. TESKA RECTANGULAR RECTANGULAIRE TREC4832 48 x 32 MANUEL D INSTALLATION INSTALLATION MANUAL IMPORTANT Read all instructions carefully before starting the installation Thoroughly inspect your product before proceeding with the installation The warranty will be void if the product is installed with an apparent defect CAUTION To prevent leaks silicone must be applied on the outside of the shower and not on the inside Save this manual for future reference IMPORTANT Veuillez lire attentivement ce manuel d instruction avant de commencer l installation Inspectez le produit avant de proc der l installation La garantie sera nulle si le produit est install avec des d fauts apparents ATTENTION la fin de l installation le calfeutrage au silicone doit se faire l ext rieur de la douche seulement Le calfeutrage l int rieur peut causer des fuites d eau Conserver ce manuel pour r f rence ult rieure 94051019 102914 A amp Bath amp Shower Bain et Douche Owner Manual and Installation Guide Manuel du propri taire et guide d installation Universal corner shower base Base de douche universelle en coin INST 120800 12FE2015 TOOLS AND MATERIAL REQUIRED OUTILS ET MAT RIAUX REQUIS 23 NT 8x1 Flat head screw Max25 Vis t te frais e No8x1 4 25 Mortar Mortier Drillbits Forets
7. all and floor structures are squared and leveled In order to secure the base in place the wall struc tures must provide a stud every 16 inches Make sure that the waste pipe and the drain hole on the base are positionned identically Avant de proc der l installation de votre base de douche assurez vous que la structure d accueil est d querre et de niveau Afin de fixer ad quatement la base la structure d accueil doit comporter des montants espac s de 16 pouces De plus assurez vous que le tuyau d vacuation et le drain de la base sont positionn s identiquement Page 5 BASE INSTALLATION INSTALLATION DE LA BASE Page 6 Place the shower base in it s location Make sure that the base is perfectly leveled With a lead pencil trace the position of the flange on the studs Also trace the outline of the base on the floor While the base is still in place drill screw holes on the flange aligned with each stud using the same diameter as the flat head screws Next countersink the screw holes with a drillbit the same diameter as the head of the screw Placer la base de douche dans son emplacement Assurez vous qu elle soit parfaitement niveau l aide d un crayon tracer la position du rebord de la base sur les montants de bois
8. ar Mortier Mortar Mortier Plastic film Pellicule de plastique Page 7 BASE INSTALLATION INSTALLATION DE LA BASE Page 8 Fold back the plastic film onto the the mortar and cut an opening for the drain and waste pipe using a utility knife Reposition the shower base into it s location Replier la pellicule de plastique sur le mortier et couper une ouverture l endroit du drain et du tuyau d vacuation l aide d un couteau lame r tractable D poser la base de douche dans son emplace ment BASE INSTALLATION INSTALLATION DE LA BASE Make sure that the base is properly leveled on all sides If some studs don t rest against the base flange place wood shims in between the flange and the studs in order to close the gap Ensure that the base is evenly supported by the mortar underneath Finally fix the base with 8x1 flat head screws using a screwdriver Do not overthighten or use electric tools Assurez vous que la base soit de niveau sur tous les c t s Si certains montants ne s appuient pas sur le rebord de la base placer des cales de bois afin de combler l espace Assurez vous que la cuve de la base soit soutenu uniform ment par le mortier Finalement fixez la base en place l aide vis No8x1 t te fraise en utilisant un tourn
9. bar is too long cut it according to the required dimension l I ROLLER BUMPER INSTALLATION INSTALLATION DE AMORTISSEUR DE ROULEMENT n HANDLE INSTALLATION INSTALLATION DE LA POIGN E THRESHOLD INSTALLATION INTALLATION DU SEUIL 4 x Place the parts the threshold of the base cut the splash back if needed Use silicone to fix it to the threshold Use left or right fixed panel bracket and secure it to the base Placer les pi ces sur le seuil de la base couper l anti claboussure si requis Utiliser du silicone pour le fixer au seuil Utiliser l ancrage de panneau fixe gauche ou droit et fixer la base CAULKING CALFEUTRAGE When the installation is complete apply a continous bead of silicone on the outside of the shower door at the junction of the shower door and the base thres hold and also along the wall jambs and the walls Wait for at least 24 hours before using the shower to let the silicone cure properly Do not apply silicone onto the INTE RIOR face of the shower door Applying silicone inside the shower door may cause WATER LEAK 24h Une fois l
10. buteur Si le dommage est caus par le transporteur contactez le imm diatement Assurez vous que toutes les pi ces sont incluses Assurez vous que la structure d acceuil est de niveau et d querre Avant de proc der l installation assurez vous que les dimensions de la structure sont conforment la plage d ajustement du produit CARE AND MAINTENANCE SOIN ET ENTRETIEN Les d tergents liquides pour vaisselles doux sont suffi sants pour garder la surface propre et brillante Rincez fond et s chez avec un chiffon propre Attention Les d tergents en poudre ou liquides abrasifs peuvent endommager les surfaces Ne jamais mettre en contact la surface avec des produits corrosifs contenant de l ac tone nettoyant de vernis ongles des solvants des d capants de l essence etc Tout produit de nettoyage doit tre test sur une petite surface non apparente avant de proc der un nettoyage complet Veuillez lire la fiche signal tique du produit de nettoyage et vous assurez qu il convient aux surfaces a nettoyer SAFETY REQUIREMENT PRESCRIPTION DE SECURITE 0 Q Work gloves Handle with care Gants de travail Manipuler avec soins Safety glasses 2 people Lunettes de s curit 2 personnes CONTENU PARTS LIST Num ro Qt Description Num ro Qt Description N
11. evis Ne pas trop serrer les vis ou utiliser des outils lec triques Wood shim Cale de bois 4 1ue1uo Al pnis Page 9 BASE INSTALLATION INSTALLATION DE LA BASE Once the base is properly secured in place wait 24 hours before proceeding with the installa tion of your wall materials Make sure to protect the shower base with a card board piece until your wall covering is finish You must leave a gap of 5mm between the gypsium board and the base flange and between the base and ceramic tiles Finally apply a bead of silicone at the junction of the walls and the base Allow 24 hours for the silicone to cure completely Une fois que la base est bien fix e veuillez at tendre 24 heures avant de proc der la finition de vos murs Assurez vous de prot ger la base l aide d une pi ce de carton pendant la finition de vos murs Un d gagement de 5mm est requis entre les panneaux de gypse et le rebord de la base ainsi qu entre la base et les tuiles de c ramiques Finalement appliquer un cordon de silicone la jonction de la base et des murs Une p riode de 24 heures est requise afin de permettre la silicone de durcir compl tement Silicone Silicone 0 25 Page 10 Before you begin carefully read all instructions Consult local building codes to ensure installation com
12. firmation representation or warranty any affirmation representation or warranty other than those contained is this warranty shall not be enforceable against A amp E or any other person A amp E reserves the right to modify this warranty at any time it being understood that such modification will not alter the warranty condi tions applicable at the time of the sale of the products in question This warranty shall not apply following incorrect operating procedures breakage or damages cause by fault carelessness abuse misuse misapplica tion improper maintenance alteration or modification of the unit as well as chemical or natural corrosion acci dent fire flood act of God or any other casualty This warranty shall not apply to stain or malfunction caused by ferrous water hard water or salty water A amp E is not responsable for transportation costs of the defective product from the installation site to A amp E or for the return of any part or for the cost of labour or services incurred in the removal or reinstallation of any part A amp E expressly disclaims and excludes any liability for the consequential or incidental damage caused or resulting from fortuitous event loss of time lost of use inconvenience unnecessa ry expenses labour material of other costs with respect to the application of this warranty or with respect to the removal or replacement of a defective product Under no circumstances shall A amp E or any of its
13. our vitre 14 chrome roller kit 27 1 Glass Wedge spacer Joint magn tique de porte Kit de cl Allan 15 Door magnetic gaskets 28 1 Allan key kit Kit d ancrage chrome 90 pour bar 2 Cl d ajustement de roulette d Chrome kit 90 for bar 29 Roller wrench tool 30 2 Bloc d installation Spacer PREPARATION PR PARATION TOOLS AND MATERIALS REQUIRED OUTILS ET MAT RIAUX REQUIS LEVEL UTILITY KNIFE DRILL SCREWDRIVER NIVEAU COUTEAU LAME R TRACTABLE SILICONE PERCEUSE TOURNEVIS 8 n DRILL BITS 1 8 3 16 ET 1 4 MEASURING TAPE SET SQUARE PENCIL MASONRY DRILL BIT RUBAN MESURER QUERRE CRAYON MAILLET DE CAOUTCHOUC 277 1 pE 25 22 y E 4 Mec Sete x lt gt gt 2 NS 2 gt t gt 9 lt N 2 9 lt X d lt 3 FIXED PANEL INSTALLATION INSTALLATION DES PANNEAUX FIXES Ins rer partiellement le joint de serrage Ajuster et serrer seulement la fin de l installation de la porte Partially insert gasket Adjust amp tighten atthe end of door installation p FRAME INSTALLATION INSTALLATION DU CADRE Si la barre de roulement est trop longue couper la dimension requise Ifthe rolling
14. representatives be held liable for injury to any person or damage to any property however arising WARRANTY GARANTIE 11 A amp E Shower amp Bath inc A amp E offre la garantie limi t e suivante sur ses produits Cette garantie s applique uniquement au propri taire original pour une utilisation domestique A amp E garantit ses produits contre tout d faut de mat riau ou de fabrication pour des conditions nor males d utilisation et d entretien pour une p riode d une ann e compter de la date d achat originale du produit par le propri taire A amp E proc dera la r paration ou au remplacement avec un produit de m me valeur sa discr tion de tout produit dont le d faut sera rapport au d taillant autoris ou A amp E durant la p riode de garantie Ni le distributeur ni le concessionnaire auto ris A amp E Shower amp Bath inc ni personne d autre n est autoris e faire d affirmations de repr sentations ou de garantie autres que celles stipul es aux pr sentes les affirmations repr sentations et garanties contrevenant cette interdiction ne sauraient s appliquer A amp E ni a personne d autre A amp E se r serve le droit de modifier cette garantie en tout temps il est entendu que de telles modifications ne changeront pas les conditions de la ga rantie applicable au moment de la vente des produits en cause La pr sente garantie ne s applique pas dans le cas d utilisations ou d op ra
15. tions non conformes ou bris ou dommages caus s par la faute la n gligence le mauvais emploi usage entretien ou alt rations ou la modification du produit de m me que par la corrosion chimique ou naturelle le feu l inondation les catastrophes naturelles ou tout autre cas fortuit La pr sente garantie ne s ap plique pas aux taches ou aux r sultats provoqu s par une eau ferreuse une eau dure ou une eau sal e Les frais de transport des produits d fectueux entre le lieu d instal lation et A amp E les frais pour le retour de toutes pi ces et les co ts encourus afin d enlever ou r installer une pi ce ou produit seront la charge du client A amp E ne sera pas responsable ni redevable pour les dommages indirects ni pour les dommages caus s ou r sultants de cas fortuits perte de temps perte d usage inconv nients d penses fortuites frais de main d oeuvre de mat riaux ou tout les autres co ts relatifs l application de cette garantie et l enl vement ou au remplacement de produits d fec tueux A amp E et ses employ s ou repr sentants ne pour ront en aucune circonstance tre tenus responsables des dommages caus s une personne ou a des biens quel que soit la source de ces dommages

Download Pdf Manuals

image

Related Search

Related Contents

Auto-leveling Rotating Laser (RL430G)  NVV 型    取扱説明書等 - アイ・オー・データ機器  Créer une Facture sécurisée  Traduction, les mots au kilo  K165  資料一覧はこちら(PDF)  User Guide MLC 52 Series  PROOF_DGPS4-6405-LED CHARGE CABLE-UG  

Copyright © All rights reserved.
Failed to retrieve file