Home

procedimiento de instalación

image

Contents

1. 6 5 mm hole at the marked location and install the included wall anchors 1x6 or Plywood Bracing Sheet Metal NOTE Confrmation of wall strength is ara Surface highly recommended before drilling ped M5 Set 2 Install the mounting bracket using the a UA rubber washer brass washer and both vee T brass nuts on back side of the installation Set Sew Bracke Bracket Drywall Set Screw surface Install the included set screw for sheet metal installation or 30 mm machine screw for drywall installations 3 Pass the hose and sensor cord through the mounting bracket slide the spout base over the mounting bracket and tighten the set screw to secure the spout to the mounting bracket INSTALLATION PROCEDURE Connect the Spout to the Controller 1 If the spout connecting hose is too long cut it to the appropriate length making sure the end is square see lll 1 2 Pushthe spout connecting hose onto the outlet barb of the controller and secure it with the hose clamp see Ill 2 Make sure that the hose clamp is placed fully against the controller 3 Connect the backup battery connector to the controller Make sure there are no obstructions between the sensor and the basin then connect the spout sensor connector to the controller see Ill 3 IMPORTANT The faucet will begin an automatic sensing range adjustment immediately after the sensor connector is plugged into the controller Do n
2. O go y 0 e El separ wl L MUT 4 LS NLas mangueras gt El soporte de suministro Y NEE La tuerca 9 llave de paso Instale el Surtidor Para Instalar Modelos Montados en el Mostrador III 4 TET Asegure el surtidor a la parte superior del mostrador con el soporte incluido y la tuerca hexagonal Asegurese de que el surtidor sea montadocon la punta apuntando hacia el centro del lavabo SPOUT Para Instalar Modelos Montados en la Pared de H lice HI 5 y 6 NO TA La adici n de un marco de 2 x6 detr s de la ubicaci n de la instalaci n del surtidor es altamente recomendable 1 Coloque la plantilla de montaje sobre lapared en la ubicaci n deseada y marque todos los orificios 8 Empaque bis Retenedor del surtidor bi Cable del sensor M a lat Perfore un orificio con un di metro de 5 8 in no Ed 16 mm en la ubicaci n del montaje del tubo de ena EUM salida centro para que pasen el tubo de suministro del surtidor y el cable del sensor 13 4 Para Instalar los Modelos Montados en Pared Cuello de Ganso lll 7 8 amp 9 PROCEDIMIENTO DE INSTALACI N Para ajustar a una superficie de madera perfore tres 3 orificios piloto con un di metro de 7 64 in 2 7 mm en las ubicaciones marcadas Para ajustar a una pared laminada o azulejo perfore tres 3 orificios con un di metro de 3 16 in b mm e inserte los anclajes hasta que est n
3. 1 TOTO 9 garantit que ses robinets de chasse lectroniques robinets et distributeurs de savon produit sont exempts de d fauts de mat riaux et de fabrication pendant l utilisation normale lorsqu il sont correctement install s et entretenus pour une dur e de trois 3 ans partir de la date d achat Cette garantie limit e est seulement offerte l ACHETEUR ORIGINAL du produit et n est pas transf rable un tiers y compris mais non de fa on limitative tout acheteur ou propri taire ult rieur du produit Cette garantie s applique uniquement aux produits de TOTO achet s et install s en Am rique du Nord Centrale et du Sud 2 Les obligations de TOTO en vertu de cette garantie sont limit es la r paration au remplacement ou l ajustement appropri la discr tion de TOTO du produit ou des pi ces d fectueuses pendant l utilisation normale condition qu un tel produit soit correctement install utilis et entretenu selon les instructions TOTO se r serve le droit d effectuer toute inspection jug e n cessaire dans le but de d terminer la cause du d faut TOTO ne facturera pas la main d oeuvre ou les pieces relatives a des r parations ou remplacements sous garantie TOTO n est pas responsable du co t du retrait du retour et ou de la r installation du produit 3 Cette garantie ne s applique pas aux l ments suivants a Dommage ou perte r sultant d une catastrophe naturelle comme un incendie un tremble
4. Contreplaqu Marquez l emplacement du trou de la non requis pour installation de la t le vis de r glage sur le mur et enlevez le ASEO Vis de R glage support de montage o H Machine Cloisons Pour la t le Percez un trou 3 16 b mm s ch s Murs Creus l endroit marqu NOTE Les forets non fourni pour les il 9 Installation de Cloisons S ches Installation de la T le mat riaux durs peuvent tre n cessaires 1x6 ou Contreplaqu s m Po ur une cloison seche la surface du mur de CA Ei creux Percez un trou de 1 4 6 5 mm la T le l endroit marqu et installez les chevilles inclus NOTE Il est fortement recommand de confirmer la solidit du mur avant de percer 2 Installez le support de montage en utilisant la rondelle en caoutchouc la rondelle en laiton et les deux crous en laiton sur le c t arriere de la surface d installation Installez l ensemble de vis inclues pour la t le ou la vis de machine pour l installation des cloisons s ches 3 Passezle tuyau et le cordon du capteur travers le support de montage faites glisser la base du bec au dessus du support de montage et serrez la vis de r glage pour fixer le bec au support de montage PIS Rondelle Vis de R glage PROC DURE D INSTALLATION Connectez le Bec au Contr leur 1 Sile tuyau de connexion du bec est troplong coupez le la longueur appropri e et assurez vous que la pointe est carr
5. Testando o produto ap s a instala o E Abra o alimentador de gua nas v lvulas de bloqueio e inspecione em toda as conex es se h IIl 1 vazamento veja III 1 E Posicione a m o em frente ao sensor para ativar o fluxo de gua s Fechar M Para o modelo de 10 segundos o fluxo de gua ir 7 N v lvula de parar automaticamente com sua m o debaixo P Ve bloqueio do sensor O fluxo tamb m deve parar quando voc remover a mao do alcance do sensor Para o modelo de 20 segundos o fluxo de gua deve parar ap s 20 segundos Cuidados e limpeza B Bica e Sensor IMPORTANTE Nao risque o sensor durante a limpeza da bica veja Ill 2 Evite o uso de quaisquer materiais de limpeza que possam riscar ou danificar a superf cie da torneira Nunca use po de polimento detergentes que possuem 27 Sensor part culas s lidas solventes derivados de benzeno subst ncias cidas ou alcalinas buchas de nylon e quaisquer outros materiais que possam danificar a superf cie da bica e do sensor difusor Para limpar a superf cie utilize um pano macio umedecido com agua e detergente neutro diluido Seque a superficie com um pano macio seco Caso isso nao limpe a superf cie de maneira adequada utilize umpano macio molhado com detergente neutro Manutengao peri dica Verifique sua torneira pelo menos uma vez por m s para os seguintes problemas potenciais e proceda com a seguinte manuten
6. suave para retirar toda la suciedad Pd Cerrar de la pantalla Llave 3 Reinstale la boquilla en el surtidor ESPECIFICACIONES Suministro de Energ a Generaci n de Hidroenerg a 5 1 8 7 7 8 130 200mm El sensor tiene ajuste autom tico un J P un Ill 2 Cepillo Boquilla del Surtidor Rango de Detecci n del Sensor Presi n del agua m nima requerida 15 psi 100 kPa fluyendo Presi n del Suministro de Agua Presi n del agua m xima 80 psi 551 kPa Conexi n del Suministro de Agua G1 2 Rango de temperatura de entrada 39 110 F 4 43 3 C Temperatura Ambiente 32 104 F 0 40 C Humedad Max 90 RH 0 09 gpc 0 36 Lpc Velocidad del Flujo 0 18 gpc 0 67 Lpc 0 19 3p610 2 Loc Tiempo de Duraci n de la 10 seguncos Descarga de Agua 20 segundos Consulte el hoja de especificaciones o con un representante de TOTO para conocer los n meros de modelo y velocidad de flujo y la duraci n de descarga de agua de cada modelo RESOLUCION DE PROBLEMAS Problema Causa Soluci n La superficie del sensor est sucia Limpie la superficie del sensor Hay una obstrucci n enfrente del Retire la obstrucci n sensor La v lvula de suspensi n est Abra la v lvula apagada El agua no empieza a El conector de la bater a de respaldo Conecte el conector de la bater a de corre
7. e voir 111 1 2 Poussez le tuyau de connexion du bec sur la bordure de la sortie du contr leur et le fixer avec le collier de serrage voir 111 2 Assurezvous que le collier de serrage du tuyau est plac compl tement contre le contr leur 3 Connectez le connecteur de la batterie de secours au contr leur Assurez vous qu il n y a pas d obstacle entre le capteur et le bassin puis connectez le connecteur du capteur du bec au contr leur voir 111 3 IMPORTANT Le robinet commencera un ajustement automatique de la plage de d tection imm diatement apr s avoir branch le connecteur du capteur au contr leur Ne mettez pas les mains ni aucun objet devant le capteur Ce processus peut prendre jusqu 20 secondes e Si la lumi re du capteur continue clignoter pendant plus de 20 secondes la direction du bec devra tre ajust e pour une op ration correcte Si l ajustement est n cessaire vous devez le faire das les 10 minutes ou le processus d ajustement se termine Pour recommencer le processus d branchez le connecteur du capteur pendant 10 secondes et rebranchez le 4 V rifiez toutes les connexions puis r installez la couverture du contr leur en la fixant avec des vis AVERTISSEMENT Tirez le cordon du capteur partir du bas du contr leur au moment de l installation de la couverture du contr l eur afin de s assurer que le cordon n est pas compress Il 1 II 2 Tuyau de raccord m Collier de Rinca
8. e em seguida instale o conector do sensor da bica no controlador veja III 3 IMPORTANTE O sensor da torneira ir comecar a ajustar o alcance do sensor automaticamente ap s ela ser ligada no controlador N o posicione as m os ou quaisquer outros objetos na frente do sensor Este processo demora aproximadamente 20 segundos at finalizado e Se a luz do sensor continuar a piscar por mais de 20 segundos o direcionamento da bica deve ser reajustado para que funcione corretamente Se for necess rio um ajuste voc deve faz lo dentro de no m ximo 10 minutos antes que acabe o processo de ajuste Para reiniciar o processo desconecte o conector do sensor por 10 segundos e ent o reconecte o 4 Verifique novamente todas as conex es e em seguida reinstale a tampa do controlador prendendo o com os parafusos AVISO Puxe levemente o cabo do sensor pela parte inferior para certificar se que o cabo n o est sendo esmagado pela bica Il 1 Ill 2 Tubo de liga o Abracadeira da bica a da mangueira 1 3 4 Abracadeira da mangueira comprimento gt 190 Tubo de liga o da bica Ill 4 Sensor e Sensor de luz i A ze Conector a E Ii ZA pa ba do sensor AIR Al AT 33 Procedimento de instala o
9. riodique Caract ristiques D pannage Garantie Robinetterie Brute MERCI D AVOIR CHOISI TOTO La mission de TOTO est d offrir au mond eentier un style de vie sain hygi nique et plus confortable comme principe de base nous concevons chaque produit avec un quilibre entre la forme et la fonction f licitations pour votre choix PIECES INCLUSES V rifiez que toutes les pi ces sont inclues dans votre paquet l apparence de certains l ments pourrait varier en fonction du modele 4 4 TEESTO TEESTI TELS14 TELST5 AJ rm c A I Gooseneck Gooseneck Wall Helix Wall Po P dd N N eS ON E IS CN N KIT ND NE Ej NX Ke o i n e a Y DEbEST TELSISA g Wg N SU by GRAVIS Wi E x B E g i PRUDENCE Veuillez lire et respecter les consignes suivantes Le non respect de ces recommandations pourrait entrainer des blessures et ou des dommages mat riels M Personne d autre qu un ing nieur de service ne devrait d monter r parer ou modifier ce robinet moins que ce ne soit d crit sp cifiquement dans ce manuel Le non respect de ces recommandations pourrait causer le dysfon ctionnement du produit R glez votre robinet seulement aux temp ratures autoris es dans vos codes locaux N utilisez pas ce robinet dans des endroits humides o l eau courante ou de la condensation pourrait s accumuler la surface particuli rement dans un saun
10. un autre chiffon doux Si cela ne nettoie pas convenablement la surface essuyez la surface avec un d tergent neutre et un chiffon humide MAINTENANCE PERIODIQUE Inspectez votre robinet au moins une fois par mois pour d tecter les probl mes potentiels suivants et pour conduire les proc dures de maintenance suivantes Inspectez pour D tecter Toute Fuite e V rifiez toutes les connexions d eau pour d tecter tout signe de fuite Serrez le Bec e Au cas ou le bec est desserr serrez l crou hexagonal sous le bec pour les modeles mont s sur pont Serrez les spirales murales du bec 1 D vissez l cusson serrez les trois vis qui maintiennent le support de montage au mur et les trois vis qui maintiennent le bec au support de montage Bec Verseur E U c Lu ac LL 2 R installez l cusson Pour serrer le bec mural col de cygne 1 Fermez la source d eau au dessus des valves et d branchez le tuyau de connexion du bec du contr leur 2 Enlevez le bec du support de montage en levant la vis de r glage au bas de la base du bec 3 Serrer la vis de r glage l arri re du bec puis r installez le bec sur le support de montage 4 Comme requis assurez vous que la vis de fixation sur le support de montage et les crous de montage derri re l vier mur Voir la section Installer le bec sont bien serr s Nettoyez le Tamis d Entr e et le Bec Verseur e Lorsque le tamis de l entr e est bouch le d bit
11. AUTRES D PENSES OU DOMMAGES ACCIDENTELS PARTICULIERS OU CONS CUTIFS OCCASIONN S PAR L ACHETEUR ORIGINAL OU DE LA MAIN D OEUVRE OU DES AUTRES FRAIS DUS L INSTALLATION OU AU RETRAIT OU DES FRAIS DE R PARATION PAR DES TIERS OU DE TOUTE AUTRE D PENSE QUI N EST PAS EXPRESS MENT MENTIONN E CI DESSUS EN AUCUNE CIRCONSTANCE LA RESPONSABILIT DE TOTO NE SERA SUP RIEURE AU PRIX D ACHAT DU PRODUIT SAUF DANS LA MESURE OU CELA EST INTERDIT PAR LA LOI EN VIGUEUR TOUTE GARANTIE IMPLICITE Y COMPRIS CELLE DE VALEUR MARCHANDE OU D ADAPTATION UN USAGE OU UN EMPLOI PARTICULIER EST EXPRESS MENT EXCLUE CERTAINS TATS N AUTORISENT PAS DE LIMITATIONS SUR LA DUR E DE LA GARANTIE IMPLICITE OU L EXCLUSION OU LA LIMITATION DES DOMMAGES INDIRECTS OU CONS CUTIFS IL EST DONC POSSIBLE QUE LA LIMITATION ET L EXCLUSION SUSMENTIONN ES NE S APPLIQUENT PAS VOUS 28 NDICE Cpricaco por esco nera TOTOO m 29 Pecas inclu das Avisos Antes da instalac o Procedimento de instalac o Cuidados e limpeza Manutenc o peri dica Especificac es Resoluc o de problemas Garantia Dimens es aproximadas OBRIGADO POR ESCOLHER TOTO A miss o da TOTO proporcionar ao mundo um estilo de vida saud vel higi nico e mais confort vel Como princ pio norteador projetamos cada produto com equil brio entre forma e fun o Parab ns pela sua escolha PECAS INCLU DAS Confira para certificar se que todas estas pecas constam da em
12. a ras D golpes suaves con un martillo si es necesario Alimente el tubo de suministro y el cable del sensor a trav s del orificio de 5 8 in 16 mm en el centro Coloque el tubo de salida contra la pared y aj stelo firmem ente con los tornillos proporcionados Ajuste manualmente el escudete al soporte NOTA La adici n de un contrachapado de recubrimiento de 1 x 6 detr s de la ubicaci n de montaje es altamente recomendable para las instalaciones en pared laminada pared hueca El grosor de pared m ximo total es de 2 50mm Perfore un orificio de 1 1 8 29 mm en la ubicaci n deseada para el soporte de montaje Ponga el soporte de montaje a trav s de un orificio en la pared con el orificio del tornillo de fijaci n ubicado a las 12 en punto Marque la ubicaci n del orificio del tornillo de fijaci n en la pared y retire el soporte de montaje Para una superficie de hoja de metal Perfore un orificio de 3 16 b mm en la ubicaci n marcada NOTA Se pueden necesitar brocas de taladro no proporcionadas para materiales duros Para una superficie de pared laminada pared hueca Perfore un orificio de 1 4 6 5 m m en la ubicaci n marcada e instale los taquetes incluidos NOTA Es altamente recomendable la confirmaci n de la resistencia de la pared antes de perforar ill Me 2x4 Marco de Pared Terminada Orificio de 3 4 de Di metro para Taquetes L M Orificio d
13. bracket and mounting nuts behind the sink wall refer to Install the Spout section are tight Cleaning the Inlet Strainer and Nozzle e When the inlet strainer is clogged the flow rate will decrease Decreased flow rate can lead to insufficient power generation which will deplete the backup battery prematurely e To clean the strainer see Ill 1 E 1 Turn the water off at the stop valves 9 2 Remove controller cover and then remove Z x quick fastener 3 Remove contorller 4 Remove strainer and clean it with a brush 5 Re install the clean strainer IMPORTANT Be sure to install fow regulator in the correct ic MM egulator gt orientation as shown Otherwise product does LE not function properly N 6 Re install the controller into the adaper until M pl fully seated and secure it with the quick 2 fastener N Ouick 7 Re install cover securing it with the screws es Fastener 8 Open angle stop and check all connections Ill 2 Brush e To clean the nozzle see Ill 2 1 Remove the nozzle from the spout Spout a Nozzle with the suppplied tool ope 2 Clean the nozzle with a soft brush gt Spout to remove any dirt from the screen close Nozzle 3 Re install the nozzle in the spout Key SPECIFICATIONS Power suppl Hydropower Generation self powering power supply y 5 1 8 7 7 8 130 200mm Sensor Detect
14. de Sab o 1 ATOTO garante suas v lvulas de descarga eletr nicas torneiras e dispensadores de sab o Produto contra defeitos de material e de fabrica o durante o uso normal quando instalados e submetidos manuten o adequada por um per odo de tr s 3 anos partir da data da compra Esta garantia limitada estendida apenas ao COMPRADOR ORIGINAL do Produto e n o transfer vel a terceiros incluindo mas n o limitado a qualquer comprador ou propriet rio subsequente do Produto Esta garantia se aplica somente a Produtos da TOTO comprados e instalados no Brasil 2 As obriga es da TOTO sob esta garantia est o limitadas a reparos substitui es ou outros ajustes apropriados a crit rio da TOTO do Produto ou de pecas que apresentem defeitos durante o uso normal contanto que tal Produto tenha sido instalado usado e submetido manuten o adequada de acordo com as instru es A TOTO se reserva o direito de realizar tais inspe es conforme necess rio para determinar a causa do defeito A TOTO n o cobrar pela m o de obra ou por pe as relacionadas a reparos ou substitui es em garantia A TOTO n o respons vel pelo custo de remo o devolu o e ou reinstala o do Produto 3 Esta garantia n o se aplica aos seguintes itens a Danos ou perdas sofridos em desastres naturais como inc ndios terremotos enchentes trovoadas tempestades el tricas etc b Danos ou perdas resultantes de quaisquer aciden
15. de bloqueio Instalando a bica Para instalar o modelo Deck Mounted III 4 Prenda a bica na bancada junto com o suporte e a porca sextavada Certifique se que a bica seja montada com a ponta direcionada para o centro da pia ill 4 SPOUT Para instalar as torneiras de parede modelo Helix lll 5 amp 6 NOTA no caso da instala o deste produto em parede Empaque de dry wall a utilizac o de uma travessa 2 x4 como suporte por atr s da parede no local onde a bica ser instalada altamente recomendada Mila 1 Posicione o gabarito de instalac o na parede no local desejado para instalac o do produto e faca a marcac o d Y Cable del sensor da posi o dos furos Fa a a fura o nos locais marcados com uma broca com di metro de 5 8 16 mm no local Pal previsto para instalac o da abica para passagem do o es tubo de ligac o e do fio do sensor 31 Procedimento de instala o 2 Para a instala o em paredes de madeira ox fa a tr s 3 furos com uma broca de ix 7 64 2 7mm nas marca es Parede acabada Furo para buchas de fixac o di metro de 3 4 furos para buchas e parafusos de fixa o Para instala o em dry wall ou azulejos fa a tr s furos com uma broca 3 16 _ E bmm e insira as buchas at que elas gt 7 2x4 fiquem rentes a parede Caso ness rio TUN lt P utilize um martelo 3 Passe o tubo de ligac o
16. e o fio do sensor pelo furo at que ele alcance a fura o da bica Posicione a bica na parede e apert os parafusos fornecidos at que a bica e esteja fixa 4 Aperte a canopa de acabamento com a mao at que esteja fixa Para instalar os modelos com bica alta de parede Ill 7 8 amp 9 NOTA Caso este produto for instalado em paredes ocas ou de drywall a utilizac o de um suporte de madeira de 1 x 6 por tr s da parede na localizac o da bica altamente recomendada A espessura m xima para o ill 7 furo para o parafuso de fixa o 3 16 Superf cies finas de metal 1 4 Dry wall ou paredes ocas 15 16 cojunto parede e suporte de 50 mm 1 1 8 1 Fa a um furo de 1 1 8 29 mm no local bd desejado para instala o do conjunto de fixa o Encaixe o conjunto de fixa o no ill 8 Arruela de bronze Arruela de furo com o parafuso de fixa o posicionado acima do furo 12 horas A m Travessa de madeira Marque a localizac o dos parafusos de fixac o na parede e remova o conjunto de fixac o Parafuso de fixac o Tuerca 2 Lu un LL OU E cc O a No caso da instalac o em uma superf cie de metal Faca um furo co uma broca de 3 16 5mm na posic o marcada ill 9 Instala o em Dry wall Instalac o em superf cies met licas finas NOTA Brocas para furac o de superf cies Z Travessa de madeira extra
17. maximum 80 psi 551 kPa G1 2 39 110 F 4 43 3 C Temp rature Ambiante 32 104 F 0 40 C Humidit Max 90 RH 0 09 gpc 0 36 Lpc D bit 0 18 gpc 0 67 Lpo 0 19 ope 0 77 Lpo 10 seconde Connexion de la Source d Eau Pression de la Source d Eau La plage de temp rature d alimentation Dur e du D versement d Eau 20 seconde Reportez vous au fiche technique ou consultez un Repr sentant de TOTO pour les num ros de mod le et d bit et la dur e du rejet d eau de chaque mod le Probl me Ll eau ne commence pas couler L eau ne coule pas co ntinuellement ac U c Lu ol LL D bit faible La temp ra ture de l eau est trop lev e La temp rat ure de l eau est trop basse La temp ra ture de l eau n est pas contr l e correctement Fourchette de d tection courte D PANNAGE Cause Solution La surface du capteur est sale Nettoyez la surface du capteur Il y a un obstacle devant le capteur Enlevez l obstacle La valve d arr t est ferm e Allumez la valve La batterie de secours est Branchez les connecteurs de la d branch e batterie de secours Le g n rateur d nergie et le con Fixez solidement le s connecteurs necteur du capteur sont d branch s La source d eau est suspendue Attendez jusqu ce que la source d eau soit restaur e Le tamis ou l cran de r glage est Nettoyez le tamis et l cran r gulateur bouch La
18. temperatura cair ao n vel de congelamento isole os tubos Certifique se que o cabo de fornecimento n o entre em contato com a tubula o do alimentador de gua quente Evite colocar quaisquer objetos dentro da faixa de detec o do sensor infravermelho Respeite todos as regulamenta es locais e normas t cnicas press o est tica de funcionamento recomendada para este produto de 140 kPa a 551 kPa Caso a press o no s ponto s de alimenta o forem superior a 551 kPa reduza a press o para o intervalo recomendado LLI un LL OU E cc a E Verifique a temperatura do abastecimento de gua A faixa de temperatura de abastecimento dos pontos de gua fria e quente recomendada entre 39 F 104 F 4 C 40 C Nunca utilize vapor para abastecimento de agua quente Esvazie todas os ramais e subramais de agua antes da instala o Outras precauc es antes de comecar ome cuidado para que a superf cie do sensor n o sofra danos ou riscos durante o processo de instala o Certifique se de que todos tubos conex es v lvulas de bloqueio ramais e sub ramais foram instalados de acordo com as normas vigentes e regulamentacoes locais N o coloque outros dispositivos que utilizem um inversor ou sensor de infravermelhos perto da torneira visto que isso pode provocar um funcionamento inadequado da torneira Verifique a regulamentac o local e as normas t cnicas para sis
19. u otro ajuste apropiado a discreci n de TOTO del Producto o las piezas que resulten defectuosas en su uso normal siempre que dicho Producto fuera instalado utilizado y mantenido adecuadamente en consonancia a las instrucciones TOTO se reserva el derecho de realizar tantas inspecciones como sean necesarias para determinar la causa del defecto TOTO no cobrar por la mano de obra o piezas con respecto a las reparaciones o reemplazos de la garant a TOTO no es responsable del costo de la retirada devoluci n o reinstalaci n del Producto 3 Esta garant a no se aplica a los siguientes puntos a Dafios o p rdidas resultantes de una calamidad natural como incendio terremoto inundaci n truenos tormenta el ctrica etc b Da os o p rdidas resultantes de cualquier accidente uso irrazonable uso indebido abuso negligencia o cuidado inadecuado limpieza o mantenimiento del Producto c Dafios o p rdidas resultantes de los sedimentos o cuerpos extranos en un sistema de jab n l quido un v P un L d Da os o p rdidas resultantes de una instalaci n incorrecta o de la instalaci n del Producto en un ambiente spero o peligroso o retirada reparaci n o modificaci n inadecuada del Producto e Danos o p rdidas resultantes de sobrecargas el ctricas o rayos u otros actos que no sean responsabilidad de TOTO o que el Producto no es especificado para tolerar Da os o p rdidas resultantes del desgaste norma
20. va diminuer Une r duction du d bit peut conduire une production d lectricit insuffisante qui va appauvrir la batterie de secours rapidement e Pour nettoyer le tamis voir III 1 isl _ 1 Fermez l eau et arr tez les valves di 2 Retirez le couvercle puis d branchez attache rapide 3 D posez le contr leur 4 D posez la cr pine et nettoyez la avec une brosse 5 R installez la cr pine nettoy e IMPORTANT R gulateur Veillez installer le r gulateur de d bit dans le de flux bon sens comme indiqu Sinon le produit ne fonctionnera pas correctement 89 E saat 6 R installer le contr leur dans l adaptateur ACL P jusqu celui ci est bien en place et le fixer avec l attache rapide 7 Remettre le couvercle et le fixer avec les vis 8 Ouvrez la vanne d arr t et v rifier IIl 2 Brosse toutes les connexions e Pour nettoyer la buse voir III 2 ei 1 Enlevez la buse du bec avec les Verseur gfe outils fournis Ouvrir d TL 2 Nettoyez la buse avec un brosse Verseur douce pour enlever toute salet Pi Fermer de l cran Cl 3 R installez la buse dans le bec CARACT RISTIQUES Source d nergie La Production Hydro lectrique Champ de D tection du Capteur 5 1 8 7 7 8 130 200mm AJ rm Z A I Le capteur est auto r glable Pression minimum d eau requise 15 psi 100 kPa coulant Pression d eau
21. CLEANING IMPORTANT Do not scratch the sensor when cleaning the spout see lll 2 Never use polishing powder detergent that includes coarse particles thinners benzene acids alkaline detergents or nylon scrub brushes as they can damage the surface of the spout Sensor o safely clean the surface wipe it using a dampened soft cloth with diluted dishwashing detergent and dry it with another soft cloth If this does not Outlet adequately clean the surface wipe the area with a neutral detergent and wet cloth PERIODIC MAINTENANCE Check your faucet at least once a month for the following potential problems and to do the following maintenance procedures Inspect for Leakage Check all water connections for signs of leakage Tighten the Spout f the spout is loose tighten the hexagonal nut underneath the spout for deck mounted models To tighten the Helix Wall Mounted Spout 1 Unscrew the escutcheon tighten the three screws securing the mounting bracket to the wall 2 Reinstall escutcheon To tighten the Gooseneck Wall Mounted Spout 1 Turn off the water supply at the stop valves and disconnect the spout connecting hose from the controller 2 Remove the spout from the mounting bracket by removing the set screw on the bottom of the spout base 3 Tighten the set screw on the back of the spout then reinstall the spout on the mounting bracket 4 As required ensure the set screw on the mounting
22. ELSTO TELS TI TELS 12 TELS 14 TELS15 Gooseneck Wall Helix Wall TELST6 TELSAS NNARNINGS Please read and adhere to the following notes Failure to do so could result in personal injury and or property damage EH No person other than a service engineer should disassemble repair or modify this faucet unless it is specifically described in this manual Failure to do so may result in electric shock or product malfunction Only set your faucet to the temperatures allowed in your local codes Do not use this faucet in a humid location where running water or condensation may collect on the surface especially in a sauna or steam room I OU c TT Do not strike or kick the faucet or controller box as this may damage the unit or cause a leak Do not touch the stop valve of the controller as the surface may be very hot Disconnect the backup battery connector when the faucet is not in use for a long period of time Always close the stop valve s before cleaning the strainer Periodically check the piping for leaks If the room temperature drops to freezing wrap the pipes with insulation Make sure the power cord does not come in contact with the hot water supply pipe Avoid placing any objects within the detection range of the infrared sensor BEFORE INSTALLATION Observe all local and plumbing codes Check the cold and or hot water supply pressure The recommended working pressure rang
23. Installation and Owners Manual Manual de Instrucciones y del Propietario Manuel d Installation et d Utilisation Manual de Instalac o e do Proprietario EcoPower Automatic Faucets Grifos Autom ticos EcoPower Robinets Automatiques EcoPower Torneiras e Misturadores Eletronicos Self Power Warranty Registration and Inquiry For product warranty registration TOTO U S A Inc recommends online warranty registration Please visit our web site http www totousa com If you have questions regarding warranty policy or coverage please contact TOTO U S A Inc Customer Service Department 1155 Southern Road Morrow GA 30260 888 295 8134 or 678 466 1300 when calling from outside of U S A TABLE OF CONTENTS Thanks Tor Choosing eU Included Parts Warnings Before Installation Installation Procedures Care amp Cleaning Periodic Maintenance Specifcations Troubleshooting Warranty Z G UN 3E Rough In Dimensions THANK YOU FOR CHOOSING TOTO The mission of TOTO is to provide the world with healthy hygienic and more comfortable lifestyles We design every product with the balance of form and function as a guiding principle Congratulations on your choice INCLUDED PARTS Check to make sure you have all these parts from the package Appearance of some components may vary depending on the model SPOUT STD Helix Helix M Axiom Gooseneck T
24. TIAS IMPL CITAS INCLUINDO A DE COMERCIABILIDADE OU ADEQUACAO PARA USO OU PARA UMA FINALIDADE ESPEC FICA SAO EXPRESSAMENTE ISENTAS ALGUNS PA SES REGI ES ESTADOS ETC N O PERMITEM LIMITA ES SOBRE A DURA O DE UMA GARANTIA IMPL CITA OU A EXCLUS O OU LIMITA O DE DANOS INCIDENTAIS OU CONSEQUENTES PORTANTO A LIMITA O E A EXCLUS O ACIMA PODEM N O SE APLICAR A VOC p ROUGH IN DIMENSIONS BOSQUEJO ROBINETTERIE BRUTE DIMENS ES APROXIMADAS STD Helix am TELS105 TELS115 TELS101 E TELS111 ES A JIE e eo y E o 5 5 non
25. a ou un hammam Ne pas frapper ou botter le robinet ou la boite du contr leur car ceci pourrait endommager l unit ou provoquer une fuite Ne pas toucher la vanne d arr t de l automate que la surface peut tre tr s chaude D branchez le connecteur de la batterie de secours lorsque le robinet n est pas utilis pendant une longue p riode de temps Assurez vous de toujours fermer la valve d arr t avant de nettoyer l purateur V rifiez r guli rement les tuyaux pour d tecter les fuites Si la temp rature de la pi ce dminue au point de cong lation enveloppez les tuyaux avec un isolant Assurez vous que le cordon d alimentation n entre pas en contact avec le tuyau d alimentation d eau chaude Evitez de placer tout objet dans la zone de d tection du capteur infrarouge AVANT DE COMMENCER NW Respecter tous les codes locaux de plomberie et de construction M V rifiez la pression de la source d eau froide et ou chaude La plage de pression recommand e est de 20 psi 80 psi 138 kPa 551 kPa Si la pression d eau d approvisionnement d passe 80 psi 551 kPa veuillez r duire la pression la plage recommand e au moyen d une valve de r duction de pression vendue s par ment B V rifiez la temp rature de l alimentation en eau La plage de temp rature d alimentation recommand e est de 39 F 104 F 4 C 40 C N utilisez jamais la vapeur comme source d eau chaude B Rincez toutes les conduites
26. an pulo do controle da Regule o man pulo do controle A temperat temperatura est fixado em H da temperatura no ponto m dio ura da gua d alis A v lvula de bloqueio conectada ao Abra completamente a v lvula da BM alimentador de gua fria n o est gua fria totalmente aberta LL un LL gt OU gt E cc O a O man pulo do controle da temperatura est fixado em C Regule o man pulo do controle da temperatura no ponto m dio A v lvula de bloqueio conectada ao Abra completamente a v lvula de A temperatur alimentador de gua quente n o bloqueio de gua quente a da agua est est totalmente aberta muito baixa A temperatura do alimentador de Ajuste a temperatura do alimentador gua quente inferior a 120 F 49 C de gua quente para 120 F 49 C A temperatura da gua n o foi controlada apropriada mente Um lado da v lvula de bloqueio n o Abra completamente a v lvula est totalmente aberta O filtro ou a tela de regulagem est entupida Limpe o filtro e tela de regulagem O sensor de auto ajuste pode n o Limpe a superficie do sensor Faixa de funcionar corretamente quando detecc o curta estiver esticado ou bloqueado por got culas de gua TOTO DO BRASIL DISTRIBUICAO E COM RCIO LTDA GARANTIA LIMITADA DE TR S ANOS A garantia se aplica somente s V lvulas de Descarga Eletr nicas Torneiras e Distribuidores
27. balagem Aspecto de alguns componentes podem variar dependendo do modelo SPOUT STD i Helix M i Gooseneck TEESTOS TEESE TELS14 TESIS AISANDSNLAOd Gooseneck Wall Helix Wall To i TELS16 TELL Avisos Leia e respeite as seguintes recomendacoes A n o observancia destas recomenda es pode causar ferimentos pessoais e ou danos no equipamento Antes da instala o BI Verifique a press o nos pontos de alimenta o de gua fria e ou quente Nenhuma outra pessoa al m de um engenheiro de manuten o deve desmontar reparar ou modificar esta torneira a menos que esteja descrito especificamente neste manual Se esse procedimento n o for observado pode resultarem choque el trico ou avaria do produto Somente instale sua torneira temperaturas permitidas em seus c digos locais N o use essa torneira em um local Umido em que possa acumular gua corrente ou de condensa o na superf cie especialmente em uma sauna ou no banho de vapor N o bata ou chute a torneira ou a caixa do controlador pois isso pode danificar o aparelho ou causar um vazamento N o toque na superf cie do controlador da v lvula de bloqueio pois pode estar muito quente Desconecte o conector da bateria de reserva quando a torneira n o estiver em uso por um longo per odo de tempo Feche sempre a v lvula s antes de limpar o filtro Verifique periodicamente a tubula o quanto a vazamentos Se a
28. ce Department 1155 Southern Road Morrow GA 30260 888 295 8134 or 678 466 1300 when calling from outside of U S A
29. com um distribuidor ou prestador de servi os de produtos da TOTO ou 3 se devido ao tamanho do Produto ou natureza do defeito o Produto n o puder ser devolvido a um centro de assist ncia autorizado da TOTO a TOTO pode optar por reparar o Produto no local do comprador ou pagar pelo transporte do Produto para uma prestadora de servi os OQ e AJ C Q C rr un rr ATENCAO A TOTO n o respons vel por qualquer defeito de ou dano a esse Produto causado por cloraminas no tratamento do fornecimento p blico de agua ou limpadores contendo cloro hipoclorito de calcio ATENCAO O uso de alta concentrac o de cloro ou produtos base de cloro pode danificar seriamente os acess rios Esse dano pode causar vazamentos e outros problemas graves ESTA GARANTIA POR ESCRITO A NICA GARANTIA FEITA PELA TOTO REPAROS SUBSTITUI ES OU OUTROS AJUSTES APROPRIADOS CONFORME FORNECIDOS SOB ESTA GARANTIA SER O O NICO RECURSO DISPON VEL AO COMPRADOR ORIGINAL A TOTO NAO SER RESPONS VEL PELA PERDA DO PRODUTO OU POR OUTROS DANOS OU GASTOS INCIDENTAIS ESPECIAIS OU CONSEQUENTES INCORRIDOS PELO COMPRADOR ORIGINAL OU POR CUSTOS DE MAO DE OBRA OU OUTROS DEVIDO INSTALA O OU REMO O OU CUSTOS DE REPAROS FEITOS POR TERCEIROS OU POR QUALQUER OUTRO GASTO NAO DECLARADO ESPECIFICAMENTE ACIMA EM NENHUM CASO A RESPONSABILIDADE DA TOTO EXCEDER O PRECO DE COMPRA DO PRODUTO EXCETO QUANTO A EXTENSAO PROIBIDA POR LEI APLIC VEL QUAISQUER GARAN
30. contr leur dans le bon sens comme indiqu Sinon le produit ne fonctionnera pas correctement 5 Connectez la conduite d alimentation en eau l adaptateur d entr e voir l ill 3 REMARQUE Si vous utilisez une vanne thermostatique vendue s par ment veuillez consulter son manuel d installation pour plus de d tails ill 1 ill 2 77 Le support gt LS Zz NEES Le crou Installez le Bec Verseur Pour installer les modeles mont s sur pont III 4 Serrer le bec sur le comptoir avec le support inclus et l crou hexagonal Assurez vous que le bec est mont avec la pointe dirig e vers le centre du bassin Pour installer les mod les muraux spirale lll 5 amp 6 L ajout d une charpente 2 x 6 f derri re l emplacement du bec est fortement recommand Placez le gabarit de montage sur le mur l endroit d sir et marquez l emplacement de tous les trous Percez un trou de 5 8 po 16 mm de diam tre emplacement de montage du bec centre pour faire passer le tube d alimentation et le cordon du capteur travers 22 ill 3 AJ m Z A I Les tuyaux d alimentation querre de but e ill 4 SPOUT Joint Pd hie du capteur Bis Rondelle Le crou 7 Tuyau de raccord du bec PROC DURE D INSTALLATION 2 Pour une installation sur du bois percez ii 5 t
31. d eau avant l installation FRENCH B Autres pr cautions prendre avant de commencer Portez une attention particuli re afin que la surface du capteur ne soit pas d fectueuse ou ray e pendant le processus d installation Assurez vous que toute la tuyauterie les valves d arr t et les lignes de connexion sont install es en accordance avec les codes locaux Ne placez pas d autres appareils qui utilisent un onduleur ou un capteur infrarouge pres du robinet car ceci pourraitcauser le dysfonctionnement du robinet ll n est pas recommand d avoir une pression d eau sup rieure 80 psi pour la plupart des appareils de plomberie V rifiezvotre code de plomberie local pour plus de d tails PROC DURE D INSTALLATION Installez le Contr leur REMARQUE Avant d installer le produit soyez s r de rincer soigneusement les tuyaux d alimentation pour liminer toute salet et tous d bris Fermez la source d eau aux valves d arr t apr s le rincage 1 Voir le sommaire de la page des dimensions pour d terminer l emplacement appropri pour le contr leur 2 Enlevez les vis l avant de la couverture du contr leur et tirez pour enlever 3 Montez le support sur le mur Si n cessaire utilisez des chevilles voir l ill 1 4 Parle dessus placez le contr leur dans l orifice du support Serrez le grand crou situ sous le support pour fixer le contr leur voir Fill 2 IMPORTANT Assurez vous d installer le
32. duras podem ser necess rias 25x150 n o a companham o produto M5x30 No caso da insalac o em paredes de drywall Prensa e us Faca um furo com uma broca de 1 4 m m e 6 5mm na posic o marcada e instale as fixa o buchas de fixa o Parafuso Anilha P 7 e fixac o Paraf NOTA Recomenda se a verifica o da Drywall ferum resist ncia da parede 2 Instale o conjunto de fixac o utilizando as arruelas de borracha e de lat o e as porcas de latao na parte de tras da superf cie Instale o conjunto de parafusos de fixac o para instala o em suportes met licos ou os parafusos de 30 mm instala es em drywall 3 Passe o tubo de ligac o e o fio do sensor pelo conjunto de fixac o e deslize a base de suporte da bica Aperte os parafusos de fixac o da base da bica para fixar a bica no conjunto de fixac o 32 J e AJ ar C Q C rr un rr Procedimento de instala o Conecte a bica no controlador 1 Sea bica da mangueira de liga o estiver muito longo corte o em um comprimento apropriado e assegure se que a ponta esteja ajustada veja III 1 2 Poussez le tuyau de connexion du becsur la bordure de la sortie du contr leur et le fixer avec le collier de serrage voir 111 2 Assurezvous que le collier de serrage du tuyau est plac compl tement contre le contr leur 3 Ligue o conector da bateria de reserva no controlador Verifique se existe obstru es entre o sensor e a pia
33. e 3 16 de e Di metro para Taquetes QU X Pd SRL Se E bm 2x4 J D Montantes de md ill 6 Escudete ill 7 Orificio para el torn tornillo de m quina y anclaije de pared Orificio para el surtidor al 7 soporte de montaje illo de fijaci n 3 16 Superficie de la hoja met lica 1 4 superficie de pared laminada pared hueca 15 16 1 1 8 ill 8 Contrachapado A no se requiere para la instalaci n en hoja met lica Tornillo de Fijaci n Hoja Met lica or Tornillo de M quina pared laminada pared hueca ill 9 Instalaci n en Pared Laminada Instalaci n en Hoja Met lica Arandela de Lat n Arandela de La tuerca 2 M5x30 Tornillo de M quina y Taquetes 1x6 o Contrachapado de Recubrimiento ared Delgada Superficie de la Hoja Met lica Retenedor del surtidor Retenedor del surtidor Tornillo de Fijaci n Instale el soporte de montaje utilizando una arandela de hule arandela de lat n y ambas tuercas de lat n en la parte posterior de la superficie de instalaci n Instale el tornillo de fijaci n incluido para la instalaci n en hoja met lica tornillo de m quina de 30 mm para instalaciones en pared laminada Pase la manguera y el cable del sensor a trav s del soporte de montaje deslice la base del surtidor sobre el soporte de montaje y apriete el tor
34. e is 20psi 80 psi 138kPa 551kPa If the supply pressure is higher than 80 psi 551kPa reduce to within recommended range by using a pressure reducing vavle sold separatery Check the temperature of the water supply The recommended supply temperature range is 39 F 104 F 4 C 40 C Never use steam as a hot water supply Flush all water lines prior to installation Other precautions before you begin Pay special attention so that the sensor surface is not flawed or scratched during the installation process Make sure that all pipework stop valves and connection lines are installed according to local codes Do not place other devices that use an inverter or infrared sensor near the faucet as this may cause the faucet to malfunction Water pressures over 80 psi are not recommended for most plumbing fixtures Check your local plumbing code for details INSTALLATION PROCEDURE Install the Controller NOTE Before installing the product be sure to thoroughly flush the supply pipes of dirt and debris Shut off the water supply at the stop valves after flushing See the rough in dimension page to determine the proper location for the controller Remove the screws on the front of the controller cover and pull to remove Mount the bracket on the wall If necessary use wall anchors see ill 1 From the top place controller into the hole in the bracket From below the bracket fasten the large nut to secu
35. ge du du bec cag serrage collier de serrage Longueur de gt pu contr leur Coupe 190 Tuyau de raccord du bec Ill 3 o A Ill 4 Capteur Sf GA il QU E Connecteur Lumi re du Capteur UH du Capteur 7 A i VNS D o i gt 24 Tl rr Z e I PROC DURE D INSTALLATION Essai de l installation BI Ouvrez la source d eau aux valves d arr t et inspectez toutes les connexions pour d tecter toute fuite voir III 1 E Placez la main sous le capteur pour activer Fermer E Pour le mod le de 10s l eau s arr te de pe les dunt couler apr s 10 secondes alors que votre main est sous le capteur L eau s arr te SOM de couler d s que vous retirez votre main Pour le mod le de 20s l eau s arr te de couler apr s 20 secondes ENTRETIEN ET NETTOYAGE B Bec et Capteur IMPORTANT Ne pas rayer le capteur lors du nettoyage du bec voir 111 2 vitez d utiliser tout mat riel de nettoyage qui pourraient rayer la surface du bec Ne jamais utiliser de poudre de polissage d tergent qui comprend de grosses particules de diluants benz ne acides alcalins ou de brosse r curer en nylon comme ceux ci pourrait endommager la surface du bec Pour nettoyer la surface en toute s curit essuyez la avec une chiffon doux et humide imbib de savon vaisselle dilu et s chez avec
36. idor en el soporte de montaje 4 Seg n se requiera asegure el tornillo de fijaci n en el soporte de montaje y las tuercas de fijaci n detr s del lavabo pared consulte la secci n Instale el surtidor est n apretadas Limpiando el Filtro de Entrada y la Boquilla e Cuando el filtro de entrada est tapado la velocidad de flujo disminuir Una disminuci n en la velocidad del flujo puede llevar a una generaci n de energia insuficiente que agotar la bater a de respaldo r pidament E Ill 1 aa filtro ver IIl 1 1 Cierre el agua en las v lvulas de suspensi n 2 Retire la tapa y luego retire el sujetador r pido 3 Retire el controlador 4 Retire el filtro y limpielo con un cepillo 5 Vuelva a instalar el filtro limpio IMPORTANTE Aseg rese de instalar el regulador de flujo en la Regulador orientaci n correcta como se muestra De lo del flujo contrario el producto no funcionar correctamente pee Gu E e P TT 6 Vuelva a instalar el controlador en el Filtro S ae adaptador hasta que est completamente Ke asentado y aseg relo con el fijador r pido bs FIADOR rapida Vuelva a instalar la cubierta asegur ndola con los tornillos 8 Abra la tapa angular y verifique todas las conexiones Boquilla e Para limpiar la boquilla ver III 2 sce de 1 Retire la boquilla del surtidor con la Sa herramienta proporcionada Abrir N 2 Limpie la boquilla con un cepillo
37. ima press o de gua 80 psi 551 kPa 12 39 110 F 4 43 3 C 32 104 F 0 40 C Max 90 RH 0 09 gpc 0 36 Lpc 0 18 gpc 0 67 Lpc 0 19 gpc 0 72 Lpc 10 segundos 20 segundos Consulte as fichas de especifica o ou entre em contato com a TOTO ou um de seus representantes para c digos vaz o e volme de uso de cada modelo Resolu o de problemas Probl me Causa Soluc o A superf cie do sensor est suja Limpe a superf cie do sensor H uma obstruc o na frente do Remova a obstru o sensor A v lvula est desligada Ligue a v lvula A gua n o come ou a Conector para bateria de reserva Conecte a bateria de reserva Correr est desconectado no conector O gerador de energia e conector do Fixe firmemente o s conector s sensor est o desconectados O alimentador de gua est Aguarde at que a alimentac o suspenso da agua seja restabelecida O filtro ou a tela de regulagem est Limpe o filtro e tela de regulagem entupida A superf cie do sensor est suja Limpe a superf cie do sensor H uma obstruc o na frente do sensor A agua nao Remova a obstru o p ra de correr Se a gua continua a correr depois de tentar as solu es acima desligue a v lvula A v lvula de bloqueio n o est Abra completamente a v lvula Vee ose totalmente aberta O filtro ou a tela de regulagem esta entupida Limpe o filtro e tela de regulagem O m
38. ion Range Sensor is self adjusting Water Supply Pressure Maximum water pressure 80 psi 551 kPa 0 09 gpc 0 36 Lpc Flow Rate 0 18 gpc 0 67 Lpc 0 19 gpc 0 72 Lpc Duration Time of Water Refer to specificatin sheet or consult with a TOTO Rep for model numbers flow rate and water discharge duration of each model 8 Minimum required water pressure 15 psi 100 kPa Flowing Z G un L TROUBLESHOOTING Problem Cause Solution The surface of the sensor is dirty Clean the surface of the sensor There is an obstruction in front of Remove the obstruction the sensor The stop valve is turned off Turn on the valve Wistar wont Backup battery connector is discon Connect the backup battery connector I nected Y begin run ning The power generator and sersor Securely attach the connector s connector is disconnected E Water supply is suspended Wait until the water supply is restored The strainer or the regulating screen Clean the strainer and the regulating is clogged screen The surface of the sensor is dirty Clean the surface of the sensor Water won t There is an obstruction in front of Remove the obstruction stop the sensor running If the water continues to run after attempting the above solutions turn off the stop valve The stop valve is not fully opened Open the stop valve fully Low fow rate The strainer or the regula
39. l y habitual como p rdida de brillo rayado o desvanecimiento con el tiempo debido al uso pr cticas de limpieza condiciones atmosf ricas o agua incluyendo pero no taxativamente el uso de lej a alcalinos limpiadores cidos limpiadores secos polvo o limpiadores abrasivos o el uso de depuradores de metal o nylon 4 Para que esta garant a limitada sea v lida se requiere el comprobante de compra Se requiere que TOTO exija el registro de garant a en la compra para crear un registro de propiedad del Producto en http www se TOTO exige el registro de la garant a y si no se registra no se reducir n sus derechos de garant a limitada 5 ESTA GARANT A LE OTORGA DERECHOS LEGALES ESPEC FICOS PUEDE TENER OTROS DERECHOS QUE VAR AN ENTRE ESTADOS PROVINCIAS O PA SES 6 A fin de obtener el servicio de reparaci n de la garant a en virtud de esta garant a deber llevar el producto o entregarlo prepago a un servicio t cnico de TOTO junto con el comprobante de compra recibo de venta original y una carta que indique el problema o p ngase en contacto con un distribuidor o contratista de servicio de productos de TOTO o bien escriba directamente a TOTO U S A INC 1155 Southern Road Morrow GA 30260 888 295 8134 o 678 466 1300 si no se encuentra en los Estados Unidos Si debido al tama o del Producto o a la naturaleza del defecto el Producto no se puede devolver a TOTO el recibo de TOTO del aviso por escrito del defecto junt
40. ltro e limpe o com uma bucha ou escova Reinsale o filtro limpo IMPORTANTE Certifique se que o restritor de vaz o constante est instalado na posic o correta contorme demonstrado Caso isso n o seja feito o produto pode n o funcionar adequadamente 6 Reinstale o controlador no adaptador at que ele esteja completamente encaixado e fixo o com o grampo de fixa o 7 Reinstale a capa protetora e fixe a com os parafusos de fixa o 8 Abra a v lvula de bloqueio e verifique todas as conex es em busca de vazamentos e Para limpar o difusor veja Ill 2 1 Remova o difusor da bica com a ferramenta fornecida 2 Limpe o difusor com uma escova macia para remover qualquer sujeira do filtro 3 Reinstale o difusor na bica Restritor de vaz o constante L 4 Filtro 4 0 p man D aberto difusor Fechar a 7 AS ff A ay S ssa P c uu es sl HT M LL DEF SEL vn Z JK ZA PE L AN X x gt K 3 xA o 07 Ji E T FAN CC D w aee i d Laat Grampo Escova Fonte de alimentac o Faixa de detenc o do sensor Pressao do alimentador de agua Conex o do alimentador de agua Faixa de temperatura de entrada Temperatura ambiente Umidade Vazao Tempo maximo de abertura Gerador de energia hidrica 5 1 8 7 7 8 130 200mm O sensor auto ajust vel M nima press o de gua exigida 15 psi 100 kPa corrente M x
41. masiado aja suministro de agua caliente no est agua caliente completamente completamente abierta Fije la temperatura del suministro de agua caliente en 120F La temperatura del suministro de agua caliente es menor a 120F Abra la v lvula de suspensi n completamente La tempera Un lado de la v lvula de suspensi n atura del agua no est completamente abierto no esta contr olada adecua damente El filtro o la pantalla reguladora Limpie el filtro y la pantalla est tapado reguladora El sensor de ajuste autom tico puede Limpie la superficie del sensor Rango de det no funcionar adecuadamente cuando eccion corto est tapado o bloqueado por gotitas de agua 18 1 TOTO garantiza que sus v lvulas de descarga electr nica grifos y dispensadores de jab n Producto est n libres de defectos en los materiales y mano de obra durante el uso normal cuando se instala y se mantiene de manera adecuada por un per odo de tres 3 a os a partir de la fecha de adquisici n Esta garant a limitada se extiende solamente al COMPRADOR ORIGINAL del Producto y no es transferible a terceros incluyendo pero no taxativamente cualquier comprador o propietario subsecuente del Producto Esta garant a se aplica solamente al producto TOTO adquirido e instalado en Am rica del Norte Central y Sur 2 Las obligaciones de TOTO conforme a esta garant a se limitan a la reparaci n reemplazo
42. ment de terre une inondation la foudre un orage lectrique etc b Dommage ou perte r sultant de tout accident de toute utilisation non raisonnable incorrecte abusive ou n gligente ou de soins de nettoyage ou d entretien inappropri s du produit c Dommage ou perte r sultant des s diments ou des corps trangers pr sents dans un syst me de savon liquide d Dommage ou perte r sultant de l installation inappropri e ou de l installation du produit dans un environnement rude et ou dangereux ou le retrait la r paration ou la modification inappropri e du produit e Dommage ou perte r sultant de surtensions lectriques de la foudre ou d autres actes qui ne constituent pas la faute de TOTO ou que le produit n est pas concu pour tol rer f Dommage ou perte r sultant de l usure normale et habituelle comme la r duction de la brillance les rayures ou la d coloration au fil du temps dues l usure les pratiques de nettoyage ou l eau ou les conditions atmosph riques y compris mais non de facon limitative l utilisation de javellisant d alcalis de nettoyants acides de nettoyants secs en poudre ou de tout autre nettoyant abrasif ou l utilisation de brosses en nylon ou en m tal AJ rm Z A an 4 Pour que cette garantie limit e soit valide une preuve d achat est requise TOTO vous encourage enregistrer la garantie l achat pour cr er une d claration de propri t du produit sur http www se TOTO vou
43. nillo de fijaci n para asegurar el surtidor al soporte de montaje 14 PROCEDIMIENTO DE INSTALACI N Conecte el Surtidor al Controlador 1 Sila manguera que conecta el surtidor es demasiado larga c rtela a la longitud adecuada asegur ndose que el extremoest cuadrado ver III 1 2 Empujela manguera que conecta el surtidor en la leng eta de salida del controla dor y asegurela con la abrazadera de la manguera ver Ill 2 Aseg rese que la abrazadera de la manguera est perfectamente colocada contra el controlador 3 Conecte el conector de la bater a de respaldo al controlador Aseg rese que no haya obstrucciones entre el sensor y el lavabo despu s conecte el conector del sensor del surtidor al controlador ver III 3 IMPORTANTE El grifo comenzar un ajuste de rango de detecci n autom tico inmediatamente despu s de que el conector del sensor est enchufado al controlador No coloque las manos ni otros objetos frente al sensor Completar este proceso puede llevar hasta 20 segundos e Si la luz del sensor sigue parpadeando por m s de 20 segundos se deber reajustar la direcci n del surtidor para una operaci n adecuada Si el ajuste es necesario debe hacerlo dentro de los siguientes 10 minutos o el proceso de ajuste terminar Para reiniciar el proceso desconecte el conector del sensor 10 segundos y vu lvalo a conectar 4 Vuelva a revisar todas las conexiones despu s reinstale la cubierta del controlador a
44. o Verifique se h vazamento e Verifique em todas as conex es de agua se ha sinais de vazamento LL un LA OU gt cc O a Aperte a bica e Se a bica estiver solto aperte a porca hexagonal debaixo da bica para o modelo deck mounted Para fixar a bica de parede Helix 1 Desrosqueie a porca de acabamento e aperte os parafusos de fixac o do conjunto de fixac o preso na parede 2 Reinstale a porca de acabamento Para fixar a bica alta de parede 1 Feche a s v lvula s de bloqueio para bloquear o fluxo de agua e desconecte o tubo de ligac o do controlador 2 Remova a bica do conjunto de fixac o desrosqueando os parafusos na parte inferior da base da bica 3 Aperte os parafusos na base da bica novamente e reinstale a bica no conjunto de fixac o 4 Certifique se que o conjunto de parafusos e porcas que fixam a base de fixac o na parede atr s do lavat rio est o devidamente fixos veja a se o Instalando a Bica OQ O A C Q C rr un rr Limpeza do filtro de entrada e difusor e Quando o filtro de entrada estiver entupido a vaz o diminuir Diminuic o da vaz o pode causar a gerac o de energia insuficiente que ir esgotar rapidamente a bateria de reserva e Para limpar o filtro veja III 1 1 2 3 4 5 Remova a capa de protec o e desatarrache a Feche o registro da gua nas v lvulas de bloqueio trava de fixac o Remova o controlador Remova o fi
45. o E ed ca tz Pa DA DO des 80mm aeaa L I 3 15 16 100mm 4 15 16 2 Y L D E D E D 3 x E i A N Faucet hole 21 3 8 535mm Faucet hole 1 3 8 35mm Helix M Helix Wall 7 11 16 TELS125 TELS135 194mm TELS121 TELS131 o EX lt E II 29 e 7 5 16 Ws 186mm S S E E 4 15 16 e 2 3 16 125mm m 250mm 4 CD O ax s E Finished wall Faucet hole 1 3 8 535mm Axiom 1 1 16 27mm 57 16 Gooseneck TELS145 163mm TELS155 TELS141 TELS151 i o E E p o Co 10 Ln S gu LN meo oO o E 50mm E e 18 Oo Y Y PEZ e e MY Es gt 53 6 amp ES 5 as 147mm fD D x SI gt o De N Faucet hole 1 3 8 235mm g Faucet hole 1 3 8 35mm Controllers Gooseneck Wall TELC105 3 5 8 94mm TELS165 TELC101 4 5 8 117mm 3 5 16 83mm TEST 1 1 8 529mm l E P o E JE SIS O xo Ja 2 1T 50mm o J 2 Fe LA CN NS 2 50mm 1 11 16 42mm Max Wall thickness TOTO TOTO U S A Inc 1155 Southern Road Morrow Georgia 30260 Tel 888 295 8134 Fax 800 699 4889 www totousa com 0GU3056 Rev B Warranty Registration and Inquiry For product warranty registration TOTO U S A Inc recommends online warranty registration Please visit our web site http www totousa com If you have questions regarding warranty policy or coverage please con tact TOTO U S A Inc Customer Servi
46. o con el comprobante de compra recibo de venta original constituir la entrega En tal caso TOTO puede optar por reparar el Producto en el lugar del comprador o pagar para transportar el Producto a un servicio t cnico ESTA GARANT A POR ESCRITO ES LA NICA GARANT A REALIZADA POR TOTO LA REPARACI N REEMPLAZO U OTRO AJUSTE ADECUADO TAL COMO APARECE EN ESTA GARANT A SER EL NICO RECURSO DISPONIBLE PARA EL COMPRADOR ORIGINAL TOTO NO SER RESPONSABLE DE LA P RDIDA DEL PRODUCTO O DE OTROS DA OS INCIDENTALES ESPECIALES O CONSECUENCIALES O GASTOS INCURRIDOS POR EL COMPRADOR ORIGINAL O DE LA MANO DE OBRA U OTROS COSTOS RELACIONADOS CON LA INSTALACI N O RETIRADA O COSTOS DE REPARACIONES REALIZADOS POR OTROS O DE NING N OTRO GASTO QUE NO SE HUBIERA ESPECIFICADO ANTERIORMENTE EN NING N CASO LA RESPONSABILIDAD DE TOTO EXCEDER EL PRECIO DE COMPRA DEL PRODUCTO SALVO DISPOSICI N LEGAL CONTRARIA TODA GARANT A IMPL CITA QUE INCLUYE LA DE COMERCIABILIDAD O IDONEIDAD PARA USO O PARA UN PROP SITO PARTICULAR EST EXPRESAMENTE PROHIBIDA ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE LA DURACI N DE UNA GARANT A IMPL CITA O LA EXCLUSI N O LIMITACI N DE DA OS INCIDENTALES O CONSECUENTES POR ESO LA LIMITACI N Y EXCLUSI N ANTERIORES PUEDEN NO APLICARSE EN ESTE CASO 13 TABLE DES MATIERES Merci d Avoir Choisi TOTO Pieces Incluses Prudence Avant de Commencer Proc dure d Installation Entretien et Nettoyage Maintenance P
47. os detergentes alcalinos ni estropajos de nylon ya que pueden da ar la superficie del surtidor Para limpiar la superficie con seguridad l mpiela con un trapo remojado en detergente para trastes diluido y s quelo con otro trapo Si esto no limpia adecuadamente la superficie l mpiela conun detergente neutro y un trapo mojado MANTENIMIENTO PERI DICO Revise su grifo al menos una vez al mes para los siguientes problemas potenciales y para realizar los siguientes procedimientos de mantenimiento Inspeccione Para ver si Hay Fugas e Revise todas las conexiones de agua para ver si hay signos de fugas Apriete el Surtidor e Si el surtidor est flojo apriete la tuerca hexagonal debajo del surtidor para los modelos montados en el mostrador Para apretar el Surtidor Montado en la Pared de Helix 1 Desatornille el escudete apriete los trest ornillos que aseguran el soporte de montaje a la pared y los tres tornillos que aseguran el surtidor al soporte de montaje 2 Reinstale el escudete Para apretar el Surtidor Montado en la Pared Cuello de Ganso 1 Cierre el suministro de agua en las v lvulas de suspensi n y desconecte la manguera que conecta el surtidor del controlador Sensor Boquilla del surtidor 2 Retire el surtidor del soporte de montaje qu itando el tornillo de fijaci n en la parte inferior de la base del surtidor 3 Apriete el tornillo de fijaci n en la parte posterior del surtidor despu s reinstale el surt
48. ot place your hands or other objects in front of the sensor This process may take up to 20 seconds to complete e f the sensor light continues to fash for more than 20 seconds the spout direc tion will need to be readjusted for proper operation If adjustment is necessary you must do it within 10 minutes or the adjustment p rocess will end To restart the process unplug the sensor connector for 10 seconds then reconnect it 4 Double check all connections then re install the controller cover securing it with the screws WARNING Draw the sensor cord from the bottom of the controller while installing the controller cover to ensure that the cord is not pinched Ill 1 IL 2 Spout Connecting lu fF Hose a Hose Clamp fush Clamp with Cutting Length 90 Spout Connecting Hose 3 a Ill 4 Sensor 7 OR ZEKE Sensor ax we ES connector CL m A SLT Z G UN aE INSTALLATION PROCEDURE Testing after installation M Turn on the water supply at the stop valves and inspect all the connections for any leaks see lll 1 E Place hand under the sensor to activate Bw B For 10 sec model water will stop after 10 ge Close seconds while your hand is under the sensor Gm Valve Water will stop when you remove your hand Open For 20 sec model water will stop after 20 seconds L 4 o c TT CARE amp
49. r est desconectada respaldo El generador de energ a y el conector Fije perfectamente el los del sensor est n desconectados conector es El suministro de agua est Espere a que el suministro de agua suspendido se restablezca El filtro o la pantalla reguladora est Limpie el filtro y la pantalla reguladora tapado La superficie del sensor est sucia Limpie la superficie del sensor El agua Hay una obstrucci n enfrente del Retire la obstrucci n NO sigue sensor corriendo Si el agua continua corriendo despu s de intentar las soluciones anteriores cierre la v lvula de suspensi n La v lvula de suspensi n no est Abra la v lvula de suspensi n Velocidad del completamente abierta completamente flujo baja El filtro o la pantalla reguladora est Limpie el filtro y la pantalla tapado reguladora La manija del control de temperatura Fije la manija del control de La tempera est fija en H temperatura en el punto medio tura del agua 4 v v lvul nsi n con es demasia do La v lvula de suspensi n conectada Abra la v lvula de suspensi n de agua alta al suministro de agua fr a no est fr a completamente completamente abierta Fije la manija del control de temperatura en el punto medio La manija del control de temperatura est fija en C La tempera La v lvula de suspensi n conectadaa Abra la v lvula de suspensi n de atura del agua es de
50. r or owner of the Product This warranty applies only to TOTO Product purchased and installed in North Central and South America 2 TOTO s obligations under this warranty are limited to repair replacement or other appropriate adjustment at TOTO s option of the Product or parts found to be defective innormal use provided that such Product was properly installed used and serviced in accordance with instructions TOTO reserves the right to make such inspections as may be necessary in order to determine the cause of the defect TOTO will not charge for labor or parts in connection with warranty repairs or replacements TOTO is notresponsible for the cost of removal return and or reinstallation of the Product 3 This warranty does not apply to the following items a Damage or loss sustained in a natural calamity such as fire earthquake flood thunder electrical storm etc b Damage or loss resulting from any accident unreasonable use misuse abuse negligence or improper care cleaning or maintenance of the Product O Damage or loss resulting from sediments or foreign matter contained in a liquid soap system d Damage or loss resulting from improper installation or frominstallation of the Product in a harsh and or hazardous environment or improper removal repair or modification of the Product e Damage or loss resulting from electrical surges or lightningstrikes or other acts which are not the fault of TOTO or which the Product i
51. re the controller see ill 2 i ud dica IMPORTANT Be sure to install controller in the correct orientation as shown Otherwise product will not function properly Z G Un L 5 Connect the water supply line to the inlet adapter see ill 3 NOTE If using a thermostatic valve sold separately please refer to its installation manual for details 111 1 E ill 2 ill 3 0 Q J 0 e Mount Bracket Nut 4 Supply Hose 77 Mount Bracket O Angle Stop Install the Spout na To Install Deck Mounted Models ill 4 Secure the spout to the countertop with the included bracket and hexagonal nut Make sure that the spout is mounted with the tip directed towards the center of the basin To Install Helix Wall Mounted Models Ill 5 amp 6 NOTE The addition of a 2 x 4 framing behind the spout installation location is highly recommended SPOUT Mounting Bracket lm cord 1 Place mounting template on wall at desired location and mark all holes Drill a 5 8 16mm diameter hole at the spout mounting location center for the supply tube Spout connecting and sensor cord to pass through ese Nut Nast INSTALLATION PROCEDURE ill 5 2 For fastening to wood drill three 3 ae pilot holes 7 64 2 7mm in diameter at marked locations Finished Wall 5 8 Hole for spout oA Holes dd screws anchor
52. rois 3 trous de guidage de 7 64 po Encadrement SES HM 2 7 mm de diam tre aux emplacements ol iametre de 3 4 marqu s 4 Ancresa Trous de e i Diam tre de 3 16 Pour une installation dans une cloison LAN x ae E seche ou dans des carreaux percez trois Jam 3 trous de 3 16 po 5 mm de diam tre m wy D et ins rez les chevilles ras Enfoncez les FORD il a l gerement a l aide d un marteau au besoin 3 Faites passer le tube d alimentation et le cordon du capteur travers le trou central de 5 8 po 16 mm Placez le bec contre le mur et fixez le solidement avec les vis fournies 4 Fixez la rosace sur le support en la serrant la main Pour installer les mod les muraux col de cygne Ill 7 8 9 NOTE L ajout d un 1 x 6 ou de contreplaqu contreventement derri re l emplacement de montage est fortement recommand 1 7 Trou pourvis de r glage vis LL INE ture deal i d hi t E y pour les cloisons s ches installations dans B remus 1 4 cloisons s ches mur creux Z les murs creux L paisseur totale 5 LL II o maximale du mur est 2 50mm E LL 11 bs I e 1 Percez un trou de 1 1 8 29 mm Trou ppubsupnorFdoanoniage emplacement d sir pour monter le ill 8 support Mettez le support de montage Rondelle Rongelle Laiton travers le trou avec le trou de vis de r glage situ e la position 12 heures Jl
53. s For fastening to drywall or tile drill three 3 holes 3 16 bmm in diameter and insert anchors until fush Tap lightly with a hammer if needed 3 Feed the supply tube and sensor card through the 5 8 16mm hole in center Place spout against wall and fasten securely with the provided screws Escutcheon I o c TT 4 Fasten the escutcheon to the bracket until hand tight To Install Gooseneck Wall Mounted Models Ill 7 8 amp 9 NOTE The addition of a 1 x 6 or plywood bracing behind the mounting location is IL7 Hole forsetserew machine Gy geroak highly recommended for drywall hollow a 91 47 drywall hollow wall wall installations The overall maximum wall thickness is 2 50mm E 1 1 8 1 Drill a 1 1 8 29 mm hole at the desired Eisleiferimolunting beda location for the mounting bracket Put the mounting bracket through a hole in ill 8 MTM the wall with the set screw hole located Rubber Washer at 12 o clock Mark the location of the set screw hole on the wall and remove Plywood A not required for sheet the mounting bracket metal installation For sheet metal surface Drill a 3 16 bmm Dus hole at the marked location E edo Machine Screw NOTE Drill bits not supplied for hard materials Fu di may be required For a drywall hollow wall surface Drill a 1 4 ill 9 Drywall Installation Sheetmetal Installation
54. s encourage enregistrer la garantie l achat mais le fait de ne pas l enregistrer ne diminuera en rien vos droits de garantie limit e 5 CETTE GARANTIE VOUS DONNE DES DROITS L GAUX SP CIFIQUES VOUS POURRIEZ AVOIR D AUTRES DROITS VARIANT D UN TAT L AUTRE D UNE PROVINCE L AUTRE OU D UN PAYS L AUTRE 6 Pour obtenir une r paration sous garantie vous devez emmener le produit ou le faire livrer en port pay un centre de service TOTO avec une preuve d achat recu d achat original et une lettre expliquant le probl me ou contacter un distributeur de TOTO ou un prestataire de service pour les produits ou crire directement TOTO U S A INC 1155 Southern Road Morrow GA 30260 888 295 8134 ou 678 466 1300 si vous vous trouvez hors des tats Unis S il est impossible de retourner le produit TOTO en raison de sa taille ou de la nature du d faut la r ception par TOTO d un avis crit du d faut accompagn de la preuve d achat recu d achat original constitue la livraison En pareil cas TOTO pourrait choisir de r parer le produit sur le lieu ou se trouve l acheteur ou de payer le transport du produit vers un centre de service CETTE GARANTIE CRITE CONSTITUE LA SEULE GARANTIE OFFERTE PAR TOTO TOUTE R PARATION TOUT REMPLACEMENT OU TOUT AUTRE AJUSTEMENT N CESSAIRE COUVERT PAR CETTE GARANTIE SERA LA SOLUTION EXCLUSIVE LA DISPOSITION DE L ACHETEUR ORIGINAL TOTO N EST PAS RESPONSABLE DE LA PERTE DU PRODUIT OU D
55. s not specified to tolerate Damage or loss resulting from normal and customary wear and tear such as gloss reduction scratching or fading over time due to use cleaning practices or water or atmospheric conditions including but not limited to the use of bleach alkali acid cleaners dry powder cleaners or any other abrasive cleaners or the use of metal or nylon scrubbers gt 4 In order for this limited warranty to be valid proof of purchase is required TOTO encourages warranty registration upon purchase to create a record of Product ownership at http www se is required TOTO encourages warranty registration upon and failure to register will not diminish your limited warranty rights 5 THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE PROVINCE TO PROVINCE OR COUNTRY TO COUNTRY 6 To obtain warranty repair service under this warranty you must take the Product or deliver it prepaid to a TOTO service facility together with proof of purchase original sales receipt and a letter stating the problem or contact a TOTO distributor or products service contractor or write directly to TOTO U S A INC 1155 Southern Road Morrow GA 30260 888 295 8134 or 678 466 1300 if outside the U S A If because of the size of the Product or nature of the defect the Product cannot be returned to TOTO receipt by TOTO of written notice of the defect together with proof of purchase original
56. sales receipt shallconstitute delivery In such case TOTO may choose to repair the Product at the purchaser s location or pay to transport the Product to a service facility THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY TOTO REPAIR REPLACEMENT OR OTHER APPROPRIATE ADJUSTMENT AS PROVIDED UNDER THIS WARRANTY SHALL BE THE EXCLUSIVE REMEDY AVAILABLE TO THE ORIGINAL PURCHASER TOTO SHALL NOT BE RESPONSIBLE FOR LOSS OF THE PRODUCT OR FOR OTHER INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OR EXPENSES INCURRED BY THE ORIGINAL PURCHASER OR FOR LABOR OR OTHER COSTS DUE TO INSTALLATION OR REMOVAL OR COSTS OF REPAIRS BY OTHERS OR FOR ANY OTHER EXPENSE NOT SPECIFICALLY STATED ABOVE IN NO EVENT WILL TOTO S RESPONSIBILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR USE OR FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION AND EXCLUSION MAY NOT APPLY TO YOU 10 Z G un L un OQ P UN L INDICE Precauci n Antes de la Instalaci n Procedimiento de Instalaci n Cuidado y Limpieza Mantenimiento Peri dico Especificaciones Resoluci n de Problemas Garant a Bosquejo GRACIAS POR ELEGIR TOTO La misi n de TOTO es dar al m
57. segur ndola con los tornillos un OQ P un ae ADVERTENCIA Lleve el cable del sensor a la parte inferior del controlador mientras instala la cubierta del controlador para asegurarse que el cable no quede atrapado HI 1 Ill 2 Manguera flexible Abrazadera del surtidor de la manguera Largo de Corte 90 m with Clamp fush controller I Manguera flexible del surtidor Ill 3 Sensor Conector QO Luz del s del Sensor Sensor 15 PROCEDIMIENTO DE INSTALACI N Prueba despu s de la instalaci n M Encienda el suministro de agua en las v lvulas de suspensi n e inspeccione todas las conexiones para verificar que no haya fugas ver III 1 BN E Coloque la mano debajo del sensor para e activar L7 v lvulas de suspensi n M Para el modelo de 10 seg el agua se Fa Abrir detendr despu s de 10 segundos mientras la mano esta debajo del sensor El agua sedetendra cuando retire la mano Para el modelo de 20 seg el agua se detendra despu s de 20 segundos CUIDADO Y LIMPIEZA B Surtidor y Sensor IMPORTANTE No raye el sensor al limpiar el surtidor ver IIl 2 Evite utilizar cualquier material de limpieza que pueda rayar la superficie del surtidor Nunca utilice polvo para pulir detergente que incluya part culas corrosivas thinners benceno cid
58. surface du capteur est sale Nettoyez la surface du capteur Il y a un obstacle devant le capteur Enlevez l obstacle Si l eau continue couler apr s avoir tent toutes les solutions au dessus fermez les valves d arr t La valve d arr t n est pas Ouvrez la valve d arr t compl tement compl tement ouverte Le tamis ou l cran de r glage est bouch Nettoyez le tamis et l cran r gulateur Fixez la poign e de contr le de la temp rature au point du milieu La poign e de contr le de la temp rature est fix e H La valve d arr t connect e la source d eau froide n est pas compl tement ouverte Ouvrez la valve d arr t d eau froide compl tement Fixez la poign e de contr le de la temp rature au point du milieu La poign e de contr le de la temp rature est fix e C La valve d arr t connect e la Ouvrez la valve d arr t d eau source d eau chaude n est pas chaude compl tement compl tement ouverte La temp rature de la sourced eau Fixez la temp rature de la source chaude est plus basse que 120 F d eau chaude 120 F Un c t de la valve d arr t n est pas Ouvrez la valve d arr t compl tement compl tement ouvert Le tamis ou l cran de r glage est Nettoyez le tamis et l cran r gulateur bouch Le capteur d autor glage peut ne Nettoyez la surface du capteur pas fonctionner correctement lorsque tendu ou bloqu pardes gouttelettes d eau 2
59. temas prediais de agua fria e quente para obter mais detalhes Procedimento de instala o Instalando o controlador NOTA Antes de instalar a torneira n o se esque a de remover minuciosamente as sujeiras e os detritos dos canos de abastecimento Desligue o alimentador de gua nas v lvulas de bloqueio ap s a lavagem 1 Veja na p gina a dimens o de desbaste para determinar o local adequado para o controlador Remova os parafusos na parte frontal da tampa do controlador e puxe para remova o Instale o conjunto de fixa o na parede Caso seja necess rio utilize as buchas de fixa o veja ill 1 4 Encaixe o controlador na parte superior do conjunto de fixa o Aperte a porca do tubo de liga o pela parte inferior do conjunto de fixa o de forma que o produto fique fixo e sem vazamentos veja ill 2 IMPORTANTE Certifique se que o controlador est instalado na pos o correta Caso ele o fluxo de gua n o esteja no sentido correto o produto pode n o funcionar de maneira adequada 5 Conecte o ponto de abastecimento no conector do produto veja ill 3 NOTA Se uma v lvula termost tica n o inclusa no produto estiver sendo utilizada verifique o manual de instala o da mesma para maiores detalhes ill 1 ill 2 ill 3 AS 7 4 o e Fixac o na parede a Tuerca em G NAs mangueiras de C gt Fixac o na parede fornecimento U A Era N z V lvula
60. tes uso excessivo uso indevido abuso neglig ncia ou de cuidados limpeza ou manuten o inadequada do Produto c Danos ou perdas resultantes de sedimentos ou corpos estranhos contidos em um sistema hidr ulico d Danos ou perdas resultantes de instala o inadequada ou instala o do Produto em um ambiente severo e ou de risco ou de remo o reparos ou modifica es inadequados do Produto o que inclui o uso de componentes n o originais da TOTO e Danos ou perdas resultantes de oscila es de energia ou quedas de raios ou outros atos que n o sejam de responsabilidade da TOTO ou os quais o Produto n o seja especificado para suportar f Danos ou perdas resultantes do desgaste normal e habitual como redu o do brilho arranh es ou desbotamento ao longo do tempo devido ao uso pr ticas de limpeza ou gua ou condi es atmosf ricas incluindo mas n o limitados a o uso de alvejantes alcali limpadores cidos limpadores a seco p ou quaisquer outros limpadores abrasivos ou o uso de esponjas de metal ou nylon Para obter o servi o de reparos da garantia sob esta garantia por favor envie um e mail para suporte br toto com para obter instru es sobre como proceder com sua reivindica o Voc pode ser instru do a 1 levar o Produto ou fazer a entrega pr paga a um prestador de servi os da TOTO juntamente com o comprovante de compra recibo de compra original e uma carta declarando o problema 2 entrar em contato
61. ting screen Clean the strainer and the regu is clogged lating screen The temperature control handle is Set the temperature control Wie tes estar Dr handle to the middle point cine id The stop valve connected to the Open the cold water stop valve fully too nigh cold water supply is not fully opened The temperature control handle is Set the temperature control set at C handle to the middle point Missed The stop valve connected to the hot Open the hot water stop valve fully p m water supply is not fully opened The hot water supply temperature is Set the hot water supply temperature lower than 120 F to 120 F Water One side of the stop valve is not Open the stop valve fully tempera fully opened ture is not controlled The strainer or the regulating screen Clean the strainer and the regulating properly is clogged screen Short detec The self adjusting sensor may not Clean the sensor surface tion range work properly when strained or blocked by water droplets WARRANTY 1 TOTO warrants its electronic flush valves faucets and soap dispensers Product to be free from defects in materials and workmanship during normal use when properly installed and serviced for a period of three 3 years from date of purchase This limited warranty is extended only to the ORIGINAL PURCHASER of the Product and is not transferable to any third party including but not limited to any subsequent purchase
62. undo estilos de vida m s saludables higi nicos y c modos Disenamos cada producto gui ndonos por el principio del equilibrio entre forma y funci n Felicitaciones por su elecci n INCLUDED PARTS Asegurese que todas estas partes est n incluidas en su empacado La apariencia de algunos componentespuede variar dependiendo del modelo 4 4 TELS10 TEES TELS14 TELS1S Gooseneck Gooseneck Wall Helix Wall Ne y x NY Q i TELS OF PRECAUCI N Lea las siguientes notas y s galas siempre De lo contrario podr a resultar herido y o causar danos materiales E Ninguna persona que no sea un ingeniero de servicios debe desensamblar reparar o modificar este grifo a menos que se describa espec ficamenteen este manual No hacer lo anterior puede resultar en un malfuncionamiento del producto Fije las temperaturas del grifo Unicamente a las permitidas ensus c digos locales No utilice este grifo en una ubicaci n humeda donde se pueda acumular agua corriente o condensaci n en la superficie especialmente en unsauna o vapor No golpee o patee el grifo o la caja del controlador ya que puede danar la unidad o causar fugas No toque la v lvula de cierre del responsable del tratamiento ya que la superficie puede estar muy caliente Desconecte el conector de la bater a de respaldo cuando el grifo no est en uso por un largo periodo de tiempo Siempre cierre la s v l
63. utilicen un inversor o sensor infrarrojo cerca del grifo ya que puede causar un malfuncionamiento del grifo No se recomiendan presiones de agua superiores a 80 psi para la mayor a de los accesorios de fontaner a Consulte su c digo de fontaner a local para obtener detalles PROCEDIMIENTO DE INSTALACI N Instale el Controlador NOTA Antes de instalar el producto aseg rese de descargar perfectamente las tuber as de suministro de suciedad y desechos Cierre el suministro de agua en las v lvulas de suspensi n despu s de descargarlas 1 Vea la p gina de dimensiones en borrador para determinar la ubicaci n adecuada para el controlador 2 Retire los tornillos en la parte de enfrente de la cubierta del controlador y jale para retirarla 3 Monte el soporte sobre la pared De ser necesario use anclajes de pared vea la ilust 1 4 Desde la parte superior coloque el controlador en el orificio en el soporte Desde la parte inferior del soporte ajuste la tuerca grande para fijar el controlador vea lailust 2 IMPORTANTE Aseg rese de instalar el controlador en la orientaci n correcta como se muestra De lo contrario el producto no funcionar correctamente 5 Conecte la l nea de suministro de agua al adaptadorde entrada vea la ilust 3 NOTA Si usa una v lvula termost tica se vende por separado consulte su manual de instalaci n para obtener detalles il ill 2 ill 3
64. vula s de suspensi n al limpiar el filtro L 2 Z lt A n Revise peri dicamente la tuber a para verificar que no haya fugas Si la temperatura ambiente cae dr sticamente envuelva la tuber a con aislante Asegurese de que el cable de energ a no entre en contacto con la tuber a de suministro de agua caliente Evite colocar cualquier objeto dentro del rango de detecci n del sensor infrarrojo ANTES DE LA INSTALACI N M Siga todos los c digos locales de plomer a y construcci n NW Verifique la presi n de suministro de agua fr a y o caliente El rango de presi n de trabajo recomendado es de 20 psi a 80 psi de 138 kPa a 551 kPa Si la presi n de suministro es superior a 80 psi 551 kPa red zcala hasta alcanzar el rango recomendado usando una v lvula de reducci n de la presi n se vende por separado E Verifique la temperatura del suministro de agua El rango de temperatura de suministro recomendado es de 39 F a 104 F de 4 C a 40 C Nunca utilice vapor como un suministro de agua caliente mM Descargue todas las l neas de agua antes de su instalaci n M Otras precauciones antes de comenzar Ponga especial atenci n para que la superficie del sensor no se dafie o raye durante el proceso de instalaci n Aseg rese que toda la tuber a v lvulas de suspensi n y l neas de conexi n est n instaladas de acuerdo con los c digos locales No coloque otros dispositivos que

Download Pdf Manuals

image

Related Search

Related Contents

Diamond Multimedia Radeon X1050AGP256 User's Manual  User Manual  Nokia 6300 User Guide  DBF 4XLT - Fantech  

Copyright © All rights reserved.