Home
MANUEL D`INSTALLATION
Contents
1. 15 D ADDING CHANGING OR DELETING A USER CODE Group 1 From address 00 to address 99 relay output 1 1 Enter the master code twice 123 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 To add a user code enter the user location from 00 to 99 If the user location is free 1 beep is emitted enter the 4 or 5 digit User code 3 To change a user code enter the user location 4 beeps are emitted to indicate that user location is already programmed Enter a new 4 or 5 digit code A beep is emitted to confirm the new user code 4 To delete a User code enter the user location 4 beeps are emitted Press O O O O O in 5 digit length code or O O O O in 4 digit length code A beep is emitted to confirm the new user code NOTE If the Pin code is already programmed or is identical to the master code then 4 beeps are emitted Press B to exit from the programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode E TIME OUTPUTS This section allows to program the illumination time and the Relay activation time 1 Enter the master code twice 12 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press AO to program the key in keypad time and the keys lit time 1 beep is emitted Enter the time in 10th of second 10 for 10 seconds up to 99 for 99 seconds the backlighting dims 10 seconds after
2. 4 termes Ex Si votre code ma tre et code utilisateur est 12 36 9 il deviendra apr s manipulation 2 3 6 9 Si vous souhaitez passer d un code ma tre et donc d un code utilisateur de 4 termes 5 termes suivez la m me proc dure Lors du passage de 4 5 termes le chiffre O sera int grer par d faut devant le code maitre et donc devant les codes utilisateurs Ex Le passage du code maitre 2 3 6 9 4 termes en 5 termes devient O 2 3 6 9 Il est conseill de programmer les codes en 5 termes puis de modifier le nombre de termes C Programmation du code maitre 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code ma tre usine est 12 3 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez A5 Un bip est mis Tapez les 4 ou 5 termes du nouveau code maitre Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement D Programmation des codes Suivant le nombre de relais de votre KCIN 1 2 ou 3 relais les groupes de codes appell s aussi rangs pour le classements des codes par individus sont diff rents KCIN 1 Relais Groupe 1 Du rang 00 au rang 99 KCIN 2 Relais Groupe 1 Du rang 00 au rang 59 Groupe 2 Du rang 60 au rang 99 KCIN 3 Relais Groupe 1 Du rang 00 au rang 59 Groupe 2 Du rang 60 au ra
3. LIME NS St GARAN AU ABL Voir conditions de garantie vie limit e Refer to Limited Lifetime Warranty KCIN por e Mem n J CERT lluminated Weatherprooi rics Clavier cod r tro clair avec lectronique rar 2 ou 3 relais Range Digicode Gamme Digicode MANUEL D INSTALLATION CDVI Group Products Merci pour l achat de ce produit et pour la confiance que vous accordez notre entreprise 1 PRESENTATION DU PRODUIT m Inox m R tro clair m Faible encombrement 100 codes utilisateurs CE m De 2 3 relais HAUTE RESIS a 9 m Pose en applique m Free voltage ce O 8 m Montage avec vis Diax m Protection de la carte lectronique Hy er d port e par tropicalisation ES rest vibrations e Test brouillard salin m Signalisation lumineuse et sonore m Dimensions Lx Ix P 110 x 85 x 14 mm i 1P64 a Alimentations 12 V a 24 V AC C Certification CE 12V 48 V DC m Consommations de 30 100 mA 9 25 C a 70 C 17 B z B DEEE 20 c 8 70 C fournie avec le D certification R amp TTE amp Certification FCC CFR 47 clavier cod KCIN un part 15 compiange ce CE certification CE d ees 124 55 2 RAPPELS ET RECOMMANDATIONS Rappel de c blage Alimentations pr conis es La distance de c blage entre le KCIN et Il existe deux alimentations adapt es pour l lectronique d port e doit tre au maxim
4. R unissez le mat riel appropri Per euse tournevis m tre et suivez les recommandations de montage du KCIN et de son lectronique d port e V rifiez la distance entre le KCIN et son lectronique d port e Voir page 14 Rappels et recommendations A laide de la plaque de fixation de l lectronique d port e et du KCIN prenez les marques et percez les 2 trous de fixation for t 5 mm et profondeur minimum 35 mm ainsi que l ouverture pour le passage du c ble lectrique destin au clavier Positionnez les 2 chevilles m tal liques dans les trous que vous venez de r aliser sur la surface Passez le c ble lectrique du KCIN dans son ouverture et fixez le son support par l interm diaire des vis Diax et de l outil sp cifi que Diax cl m le coud e Positionnez les 2 chevilles plastique dans les trous Puis fixez la plaque de fixation de l lectronique d port e sur la surface de votre choix l aide des vis cruciformes t tes frais es Venez ensuite placer l lectronique d port e sur son support Passez vos fi Is glissez les passefils de l lectronique d port e et faites vos branchements Lors de cette op ration n oubliez pas de placer la varistance Voir page 14 Rappels et recommendations cdvi com cdvigroup com 3 Le cavalier sur P3 permet de changer le code d entr e L par l utilisateur Le cavalier doit tre pla
5. 1 Cut the power Put the jumper on P2 2 Put the power back Wait approximately 3 seconds Two beeps are emitted to confirm reset of the keypad Remove P2 jumper The master code is restored to its default value 1 2 3 4 5 and all the User codes are deleted from the keypad B SETTING CODE LENGTH 1 Enter the master code twice 12 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode Press A4 to program the code length One beep is emitted Press 4 or 5 for the digit code One beep is emitted to confirm programming of the code length Press A5 to modify the master code One beep is emitted Enter the new 4 or 5 digit master code One beep is emitted to confirm programming of the new master code Press B to exit from programming mode 2 beeps are emitted to confirm that the key pad is in stand by operating mode 4 beeps indicate a data computing error C CHANGING THE MASTER CODE The master code is used only to enter in programming mode Enter the master code twice 12 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode Press A5 to modify the master code One beep is emitted Enter the new 4 or 5 digit master code One beep is emitted to confirm that the master code is programmed Press B to exit from the programming mode 2 beeps are emitted to confirm that the key pad is in stand by operating mode cdvi com cdvigroup com
6. SYT1 8 10 CE sis N S ALISM X WEEE CD Ai CD i Environmental tests vibrations e Environmental test Salt spray s rei C CE Certification 9 5603 70 C were Q9 20 C to 70 C HE Certified FCC CFR 47 R amp TTE certification C Part 15 compliant CE CE Certification d 152 Security advice For security reasons change the factory default master code When selecting a master code and user code avoid simple codes example 3456 7 Recommended power supplies suitable for the KCIN ARD12 230V input and BS60 230V input cdvi com cdvigroup com 11 Mounting recommendations Mount the keypad on a flat surface to avoid any vandalism and to insure the best mounting 3 PACKAGE CONTENTS Back EMF protection To secure the system from back electromagnetic fields do not forget to mount the varistor in parallel on the lock terminal electronic mounting plate Remote electronic KCIN sealed cap Diax screws M5x35 ME 4 MOUNTING INSTRUCTIONS Make sure that you have all the appropriate tools drill Plastic anchor Screw Brass M4x30 anchor screw drivers and a meter tape and follow the mounting instructions of for the KCIN keypad and for the remote electronic Verify the distance between the KCIN keypad and its remote electronic refer to page 3 N
7. audible Il est possible d autoriser les bips sonores touches 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 123 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez AA Un bip est mis Tapez 0 pour supprimer les bips touches pendant la composition du code d ouverture Tapez 1 pour autoriser les bips touches pendant la composition du code d ouverture Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sonores sont mis pour confirmer le retour au mode normal de fonctionnement MANUEL D INSTALLATION m KCIN Clavier cod r tro clair avec lectronique d port e Ci joint un tableau r capitulatif qui vous servira indiquer le code attribu chaque utilisateur KCIN 1 Relais KCIN 2 Relais KCIN 3 Relais RAPPEL Groupe 1 Du rang 00 au rang 99 Groupe 1 Du rang 00 au rang 59 Groupe 1 Du rang 00 au rang 59 Groupe 2 Du rang 60 au rang 99 Groupe 2 Du rang 60 au rang 79 Groupe 3 Du rang 80 au rang 99 cdvi com cdvigroup com 9 Les soci t s CDVI garantissent que ce produit est d pourvu de tout vice cach tant dans les mat riaux que dans sa fabrication la condition qu il soit install conform ment aux pr conisations du fabricant et qu il n y ait pas eu d interventions ou de modifications sur le produit La responsabilit de C
8. the last keypress or switches off after entering a valid code Press 00 for permanent cdvi com 16 cdvigroup com illumination keys One beep is emitted to validate the time Press A1 to program relay 1 output time door release time 1 beep is emitted For a latched output enter the time in seconds 01 for 1 second up to 99 for 99 seconds Press 00 for a toggled output One beep is emitted to validate the time Press B to exit from programming mode 2 beeps are emitted to confirm that the key pad is in stand by operating mode 4 beeps indicate a data computing error F RESET MASTER CODE On stand by operating mode put a jumper on P2 Wait 1 second and then remove the jumper One beep is emitted The master code is restored to its default value 1 23 4 5 in 5 digit code and 1 23 4 in 4 digit code G CHANGING THE CODE BY A USER To authorize a user to modify its own User code put a jumper on P3 to disable the feature remove the jumper 1 Enter the old user code The relay is activated and a beep is emitted Enter the 2 digit sub master code default sub master code A and B A beep is emitted to authorise the modification Enter the new user code 2 beeps are emitted to confirm the new code Check the new user code to be sure of the modification H SETTING A SUB MASTER CODE The Sub Master code allows the user to change its own code without entering in programming mode For securit
9. 1 bip court Mise sous tension 1 bip long Validation d une saisie en programmation ou ouverture autoris e 2 bips courts Entr e ou sortie de programmation 4 bips courts Erreur de saisie Termes utilis s et codes d ouverture Toutes les touches du clavier sont autoris es pour composer les codes Le code maitre et les codes d ouverture de porte doivent tre compos s de 4 ou 5 termes Le code maitre ne peut pas tre utilis comme code d ouverture Lescodes00000e6t 0000 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte Cavalier P2 Code maitre usine 12345 et RAZ des codes Cavalier P3 Modification des codes par l utilisateurs Le code maitre est de nouveau 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12 3 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Puis tapez A6 Un bip sonore est mis 3 Tapez A et B La remise z ro est valid e Attendez que deux bips soient mis Le code maitre est de nouveau 1234 5 et tous les codes sont effac s Le clavier est sorti de programmation et les valeurs par d faut sont r tablies Vous avez aussi une seconde possibilit pour remettre z ro la m moire 1 Coupez l alimentation et positionnez un cavalier en P2 Pour avoir plus de pr cision sur l emplacement du cavalier P2 reportez vous aux pages 1
10. 6 17 18 2 R tablir l alimentation Attendre environ 3 secondes 2 bips sonores sont mis pour confirmer la remise z ro Enlevez le cavalier P2 cdvi com cdvigroup com 1 23 45 et tous les codes sont effac s Les valeurs par d faut sont r tablies B Programmation du code maitre et du nombre de termes 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez A4 pour la saisie du nombre de termes des codes Un bip est mis Tapez 4 ou 5 pour le nombre de termes Un bip sonore est mis pour confirmer la programmation 3 Tapez A5 pour changer le code maitre Un bip est mis Tapez les 4 ou 5 termes du nouveau code maitre Un bip sonore est mis pour confirmer la programmation 4 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement 4 bips indiquent une erreur de saisie MANUEL D INSTALLATION KCIN Clavier cod r tro clair avec lectronique d port e Cas de figure Vous avez un code ma tre et des codes utilisateurs 5 termes Vous souhaitez utili ser des codes 4 termes Vous faites donc la d marche indiqu e ci dessus en modifiant le code maitre Lorque le nombre de terme du code maitre est bien pass de 5 4 termes les codes utilisateurs deviennent simultan ment des codes
11. DVI se limite la r paration ou l change du produit CDVI n assume aucune responsabilit concernant les dommages sur les biens ou les personnes Un produit reconnu d fectueux par CDVI doit tre retourn au service apr s vente de CDVI apr s l obtention du num ro d autorisation de Retour de Produit s D fectueux RMA La responsabilit de CDVI se limite la r paration ou au remplacement d un produit ou pi ces d fectueuses en ses ateliers L une ou l autre de ces interventions sont d finis par le service apr s vente de CDVI Le pr judice imputable CDVI ne saurait en aucun cas d passer la valeur du produit La responsabilit de CDVI ne peut tre engag e aupr s de l acheteur installateur client final ou qui que ce soit lors dedommages cons cutifs des imperfections ou mauvais fonctionnement du produit Cette garantie prend effet la date d enregistrement du produit aupr s de CDVI partir de l instant ou la date d enregistrement est d ment compl t e dans la limite d un mois apr s la date de livraison au client final Pour obtenir les d tails complets de cette garantie et enregistrer votre vos produit s pour b n ficier de cette Garantie Vie limit e Veuillez compl ter la carte d enregistrement pr sente dans la boite du produit et nous la retourner par email ou par courrier l adresse de l entit CDVI la plus proche ou vous enregistrer en ligne l adresse www cdvigroup com Les contacts des
12. IN CMYK A5 EN FR 02 Manufacturing Access Control since 1985 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI Group FRANCE Headquarter Si ge social Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBERICA SPAIN PORTUGAL Phone 34 0 935 39 09 66 Fax 34 0 935 39 09 70 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 CDVI MAROC Phone 212 0 5 22 48 09 40 Fax 212 0 5 22 48 34 69 e information contained within this document photos drawing features specifications and dimensions could be perceptibly different and can be changed without prior notice All EK CDVI SWEDEN SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 Fax 46 0 31 748 09 30 CDVI UK UNITED KINGDOM IRELAND Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86 Toutes les informations mentionn es titre indicatif sur le pr sent document photos dessins caract ristiques techni
13. IN Keypad mode Outputs Description Fail secure lock H Closed Ov Input voltage 12V to 24VAC or 12V to 48VDC v Varistor P oe lip eve Input voltage 12V to 24VAC or 12V to 48VDC R O N C contact relay 1 Ca common relay 1 Request to Exit inputs N O contact relay 1 P1 request to exit input activates relay 1 R O N C contact relay 2 de RUM input activates relay 2 r i Se en Eer atch or toggled output N O contact relay 2 OOOO 00 WOO H input can be used with RSR ea aca oR Rene by pressing on any digit key Ge When the contact is open then the request to enter is disabled When the contact is closed then press ee any key on the keypad to enter Green or Blue wire illumination cdvi com cdvigroup com 13 a P3 jumper allows to the user to modify L its own Pin code To enable this feature put the jumper on see Programming section in the instruction manual E P2 jumper resets the key pad to factory default L values Remove the power from the keypad then put the jumper see Programming section in the instruction manual Power supply 12 to 24VAC or 12 to 48VDC Power supply According to lock specifications Outputs Description as Input voltage 12V to 24VAC or 12V to 48VDC Input voltage 12V to 24VAC or 12V to 48VDC N C contact relay 1 R ec Common relay 1 N O contact relay 1 Re N C contact relay 2 r
14. arron Clavier vert ou bleu clairage D 693 Electronique d port e V2 des esr qe Tal Ml le Mia H Ouvert clavier cod Bl G che mission H ferm v Varistance bouton poussoir Commande par bouton poussoir Le raccordement du bouton poussoir Pi est pr vu pour commander le relais 1 Le raccordement du bouton poussoir P2 est pr vu pour commander le relais 2 Le mode et la temporisation sont programmables Le contact horloge H permet l utilisation de toutes les touches comme bouton ext rieur Si le contact horloge est ouvert les touches sont utilis es comme des termes habituels Si le contact horloge est ferm toutes les touches sont utilis es pour l ouverture libre KCIN en fonction KCIN en fonction COU OU LE TEE D UU 000000 SS D 9 0 9 cdvi com cdvigroup com A Remise z ro de la m moire 6 Les valeurs du KCIN sont par d faut mg Sans codes a Temporisation clairage 10 s am lemporisation d ouverture pour tous les relais 1 secondes a Nombre de termes 5 a Code maitre usine 12 3 4 5 a Temporisation s curit programmation 120 secondes a Termes de modification par utilisateur Version 1 relais Groupe 1 A et B Version 2 relais Groupe 2 let3 Version 3 relais Groupe 3 4 et 6 Lors de la programmation certaines manipulations ont comme cons quences des signaux sonores
15. ation Number provided by CDVI CDVI at its option shall repair or replace the defective product at CDVI premises or at any CDVI approved service center This warranty does not cover any damage due to accident misuse abuse or negligence This warranty is valid only if the product is registered within 1 month from delivery to the final costumer To obtain full details of this warranty and to register the product to commence the Limited Lifetime Warranty complete the enclosed registration card and return it either by e mail or post to the relevant CDVI address or completion of the on line registration at www cdvigroup com Repair or replacement of the defective product is the exclusive remedy CDVI shall not be liable for any incidental or consequential damages arising from any defect in or malfunction of its product In no event the entire liability can not exceed the purchase price of the product The CDVI local country contact details can be found on line by visiting www cdvigroup com or on the back cover of the installation manual DISCLAIMER OF WARRANTY EXCEPT AS STATED ABOVE CDVI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF ITS PRODUCTS THE TRANSPORTATION THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE 9 NOTES Refer to complete limited lifetime warranty on cdvigroup website cdvi com cdvigroup com 19 Reference G0301FR0263V03 Extranet EXE CDVI IM KC
16. c pour les modifications et enlev pour verrouiller cette option voir chapitre Programmation E Le cavalier sur P2 permet mi de r aliser une remise z ro de la m moire Le cavalier doit tre plac hors tension pour que la manipulation fonctionne voir chapitre Programmation Alimentation 12 24VAC ou 12 48VDC Alimentation 6t commande de puissance Bornier Correspondance V Alimentation 12 V 24 V AC ou 12 V 48V DC v Varistance KCIN en fonction Alimentation 12 V 24 V AC ou 12 V 48V DC ORI O Contact repos du relais 1 7 S mm Commande par bouton poussoir PEEL Le raccordement du bouton poussoir P1 Contact travail du relais 1 est pr vu pour commander le relais 1 Contact repos du relais 2 Le raccordement du bouton poussoir P2 est pr vu pour commander le relais Commun du relais 2 SENE 2 Le mode et la temporisation Contact travail du relais 2 sont programmables utilisation de toutes les touches D 693 Electronique d port e HEEL UU UO LEE D UU V R1 C1 T1 R2 C2 T2 P1 M P2 PX Q DJ UL p V ww H Ouvert KCIN en fonction clavier cod E lll G che mission H ferm bouton poussoir OOOO 00 WOO Bouton int rieur de sortie relais 2 Sa bouton exterieur l le contact horloge est ouvert les Contact horloge touch
17. elays Group 3 4 and 6 Audible signal The buzzer indicates different audible signals It can be turned off by cutting the ST1 wire on the remote controller 1 short beep Keypad powered 1 long beep Data computing in programming or access granted 2 short beeps Enter or Exit from programming 4 short beeps Data computing error Code length The master code and the User codes can be of 4 or 5 digit in length All the keypad keys can be used to program a code The master code and the Pin code can be of 4 or 5 digit code The master code CAN NOT be used as a PIN code User Pin code The master code CAN NOT be used as a PIN code User Pin code To delete a specific User pin Code replace it by 0000 if code length is 4 digit format or replace it by 00000 if the code is in 5 digit format P2 jumper Reset master code and user codes P3 jumper modification of individual code by the user A RESET MASTER CODE AND USER CODES 1 Enter the master code twice 1 23 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press A6 to reset the Master Code and the User codes One beep is emitted Press on A and B to confirm reset of all memory of the keypad Wait for two beeps The master code is restored to its default value 12345 and all the User codes are deleted from the keypad Once the reset is completed then the keypad returns to a stand by operating mode OR
18. entit s CDVI sont accessibles en ligne l adresse www cdvigroup com ou au dos de la notice d installation EXCLUSIONS DE LA GARANTIE Al EXCEPTION DES POINTS EVOQUES PRECEDEMMENT CDVI N APPLIQUE AUCUNE GARANTIE NI DELIBEREE NI TACITE A TOUS LES PROBLEMES INCLUANT LE CONDITIONNEMENT LE TRANSPORT LEUR COMMERCIALISATION OU LES CONDITIONS D UTILISATIONS PARTICULIERES 9 NOTES Voir conditions de garantie vie limit e INSTALLATION MANUAL KCIN Illuminated weatherproof Keypad with Remote Electronics 1 2 or 3 relays Thank you for buying our products and for the confidence you placed in our company 1 PRODUCT PRESENTATION m Stainless steel m Backlit keys gm Compact m From 2 to 3 relays HIGH H m Surface mount m Free voltage Mounting with Diax screws m PCB of remote electronics protected with a varnish coating m 100 user codes customisable by each user m Audible and visual feedback m Dimensions L x W x D 110 x 85 x 14mm m Power supplies 12 V to 24V ac 12 V to 48V dc m Consumptions 30 to 100mA x UU Remote 147 electronics included Leen with the KCIN 124 SC 2 NOTES AND RECOMMENDATIONS Cable The distance between the KCIN and the remote electronic can not exceed more than 10 meters Make sure that the cable is not near by a high voltage cable ex 230 V AC Recommended cable between The KCIN and the remote electronic 2 pair cables 4 wires
19. es E Common relay 2 N O contact relay 2 R N C contact relay 3 ees ae Common relay 3 N O contact relay 3 Pi Request to exit input relay 1 M Common of inputs P2 Request to exit input relay 2 H Timer Contact White wire from keypad Ee Brown wire from keypad ET ERES Green or Blue wire illumination cdvi com 14 cdvigroup com T1 R2 C2 T2 R3 C3 T3 P1 M P2 ME H Open Fd Fail safe lock KCIN Keypad mode a Fail secure lock H Closed KCIN Request to v Varistor Enter mode Request to Exit inputs P1 request to exit input activates relay 1 P2 request to exit input activates relay 2 Latch or toggled output H input can be used with a timer to enable free access by pressing on any digit key on the keypad When the contact is open then the request to enter is disabled When the contact is closed then press any key on the keypad to enter TOU OU LE TET D UU 6066000 LS D 0 9 INSTALLATION MANUAL KCIN Illuminated weatherproof Keypad with Remote Electronics 1 2 or 3 relays Default values Without codes Illumination time 10 seconds Relay release time 1 second Code length 5 digit Master Code 1234 5 Programming security time 120 secondes Code length for sub master code m Version 1 relay Group 1 A and B m Version 2 relays Group 2 1and 3 m Version 3 r
20. es sont utilis es comme des termes Clavier fil blanc habituels Si le contact horloge est ferm clavier DEEN toutes les touches sont utilis es pour l ouverture libre Clavier vert ou bleu clairage P Bouton int rieur de sortie relais 1 Le contact horloge H permet cdvi com 4 cdvigroup com MANUEL D INSTALLATION KCIN Clavier cod r tro clair avec lectronique d port e 7 SCH MA DE RACCORDEMENTS KCIN 3 RELAIS Le cavalier sur P3 permet de changer le code d entr e L par l utilisateur Le cavalier doit tre plac pour les modifications et enlev pour verrouiller cette option voir chapitre Programmation Le cavalier sur P2 permet de r aliser une remise z ro de la m moire Le cavalier doit tre plac hors tension pour que la manipulation fonctionne voir chapitre Programmation a Alimentation 12 24VAC ou 12 48VDC Alimentation c t commande de puissance Bornier Correspondance Alimentation 12 V 24 V AC ou 12 V 48 V DC V V Alimentation 12 V 24 V AC ou 12 V 48 V DC R O Contact repos du relais 1 Commun du relais 1 n Ra contact repos du relais 2 c2 commun dures Rs contact repos au els 3 es commun dureas3 oo a Bouton int rieur de soie es pa Bouton int rieur de sorte res EH contact ho oge ooo Teaver a Clavier fil m
21. nd N C contacts 8A 250V Group 1 From user location 00 to user location 59 to activate relay 1 Group 2 from user location 60 to user location 99 to activate relay 2 Release Time of relay2 enter A2 sub master code enter A8 default values 1 and 3 KCIN 3 3 relay outputs N O and N C contacts 8A 250V Group 1 from user location 00 to user location 59 to activate relay 1 Group 2 from user location 60 to user location 79 to activate relay 2 Group 3 from user location 80 to user location 99 to activate relay 3 Release time for relay 3 enter A3 sub master code enter A9 default values 4 and 6 cdvi com cdvigroup com 17 User location KCIN 1 Relays 1 output 3 KCIN 2 Relays 2 output 3 KCIN 3 Relays 3 outputs Relay 1 From user location Relay 1 From 00 to 59 Relay 1 From 00 to 59 REMINDER 00 to 99 Relay 2 From 60 to 99 Relay 2 From 60 to 79 Relay 3 From 80 to 99 cdvi com 18 cdvigroup com INSTALLATION MANUAL m KCIN Illuminated weatherproof Keypad with Remote Electronics 1 2 or 3 relays 8 LIMITED LIFETIME WARRANTY EXTRACT CDVI warrants this product to be free from defects in material and workmanship when it has been installed in accordance with the manufacturer s instructions and has not been modified or tampered with Only product recognized by CDVI to be defective should be returned under these warranty terms if accompanied by an RMA Return Material Authoriz
22. ng 79 Groupe 3 Du rang 80 au rang 99 Tapez 2 fois le code ma tre Pour la premi re utilisation le code maitre usine est 1 2 3 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation Tapez le n du rang programmer en fonction du nombre de relais de votre KCIN Si le rang est libre tapez les 4 ou 5 termes du code Si le rang est occup 4 bips sont mis Tapez les 4 ou 5 termes du code outapez0O00000u0000 pour annuler le code enregistr Un bip sonore est mis pour confirmer la programmation Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement Si le code compos correspond un code existant ou s il est identique au code ma tre 4 bips sonores indiquent une erreur Les codes 00000 et 0000 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte E Programmation des temporisations 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code ma tre usine est 123 4 5 Deux bips sonores sont mis pour confirmer l entr e en programmation Tapez AO pour la temporisation du clavier Un bip sonore est mis Tapez la dur e de commande en secondes Ex De 10 pour 10 secondes 99 pour 99 secondes ou tapez 00 pour obtenir un clairage permanent Un bip sonore de validation est mis Relais 1 Groupe 1 Tape
23. otes and Recommendations Place the back plate of the KCIN on the wall and the bracket of the remote electronic then mark with a pen the hole location then drill the 2 mounting holes drill bit 5 mm and 35 MM hole depth and the hole wiring access cdvi com 12 cdvigroup com Insert the 2 plastic anchors in the holes Place the back plate of the KCIN and screw on the wall using the supplied M4x30 mounting screws Mount the KCIN keypad on the wall with the M5x35 DIAX screws Insert the cable in the remote elec tronic and wire the cable to the ter minals Don t forget to install the varistor on the lock refer to page 3 Notes and Recommendations INSTALLATION MANUAL KCIN Illuminated weatherproof Keypad with Remote Electronics 1 2 or 3 relays 6 WIRING DIAGRAM KCIN 2 RELAY OUTPUTS D 693 Remote electronics a P3 jumper allows to the user to modify L its own Pin code To enable this feature put the jumper on see Programming section in the instruction manual TOU UO UO LEE D UU B P2 jumper resets the key T1 R2 C2 T2 pad to factory default L values Remove the power from the keypad then put the jumper see Programming section MI in the instruction manual Power supply 12 to 24VAC or 12 to 48VDC S SZ za Pi P2 H Green or blue Power supply BO According to lock e e dt specifications H Open KC
24. ques et dimensions peuvent varier et sont susceptibles de modifications sans notification pr alable
25. sation 4 et 6 Un bip sonore est mis pour autoriser le changement 3 Composez le nouveau code d ouverture Deux bips sonores confirment la validation du nouveau code et le retour un fonctionnement normal 4 V rifiez la m morisation du nouveau code en le composant Programmation des termes de modifications 1 Tapez 2 fois le code maitre Pour la premi re utilisation cdvi com cdvigroup com le code maitre usine est 123 4 5 Deux bips sont mis pour confirmer l entr e en programmation 2 Relais 1 Groupe 1 Tapez A7 Relais 2 Groupe 2 Tapez A8 Relais 3 Groupe 3 Tapez A9 Suivant le nombre de relais cette saisie vous permettra de composer les nouveaux termes de modifications des codes utilisateurs pour chaque groupe Un bip est mis Tapez les deux termes de modification Un second bip sonore est mis pour confirmer la programmation Ex KCIN 3 Relais Tapez A7 puis composez les deux termes de modifications Puis r p tez l op ration en tapant A8 et une nouvelle fois en composant A9 3 Tapez B pour sortir de la programmation Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement Programmation du signal sonore Le signal sonore est toujours audible en programmation Il en est de m me lors de la commande d ouverture suite la reconnaissance d un code Par d faut lors de la composition du code d ouverture aucun bip sonore touche n est
26. um le clavier cod KCIN ARD12 et BS60 de 10 m Attention de ne pas passer vos fils proximit Composition des codes de c bles Courant fort ex 230 V AC Par soucis de s curit veillez modifier le code maitre usine par celui de votre choix C bles pr conis s entre le KCIN Lors du changement du code maitre usine et l lectronique d port e et de la cr ation des codes utilisateurs vitez C bles 2 paires 4 fils SYT1 8 10 me les codes trop simples ex les suites 3 4 5 6 7 Tension libre cdvi com 2 cdvigroup com MANUEL D INSTALLATION KCIN Clavier cod r tro clair avec lectronique d port e Recommandations d installation Pour s curiser l installation n oubliez ext rieures pas de placer la varistance sur le syst me de verrouillage en parall le au niveau de l alimentation L lectronique d port e du KCIN doit tre imp rativement install e dans un environnement 3 ELEMENTS INCLUS Montage clos et prot g e des conditions climatiques Afin d optimiser la fixation du KCIN et de pr venir planes les tentatives d arrachage privil giez les surfaces Electronique d port e 4 MONTAGE O4 Plaque de Vis Diax Cl m le fixation de Varletance a t te coud e l lectronique frais e pour vis d port e M5x35 Diax LS fe p d ELI Vis cruciforme Cheville t te frais e m tallique M4x30 Cheville plastique
27. y reasons the code need to be changed periodically This feature makes it easier INSTALLATION MANUAL KCIN Illuminated weatherproof Keypad with Remote Electronics 1 2 or 3 relays and faster to change its code 1 Enter the master code twice 12 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press A7 to program a sub master code for the user individual Pin code modification One beep is emitted Enter the new 2 digit sub master code One beep is emitted to confirm programming of the sub master code 3 Press B to exit from the programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode I Audible Feedback The audible signal is enabled in programming mode and when the relay is energised after a valid code To enable the audible feedback on a key press 1 Enter the master code twice 1 23 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press AA One beep is emitted Press O to disable the audible signal during a keypress Press 1 to enable the audible signal during a keypress One beep confirms the new setting 3 Press B to exit from programming 2 beeps are emitted to confirm exit from programming mode J OPTIONAL KCIN 2 AND KCIN 3 PROGRAMMING INSTRUCTION Programming instructions are the same as for the KCIN keypad with 1 relay output KCIN 2 2 relay outputs N O a
28. z A1 Relais 2 Groupe 2 Tapez A2 Relais 3 Groupe 3 Tapez A3 Cette manipulation vous permet de g rer la temporisation des relais cdvi com cdvigroup com 7 8 Vous devez r aliser la d marche pour chacun des relais de votre KCIN Un bip sonore est mis Tapez la dur e de commande en secondes Ex De 01 pour 1 seconde 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais Un bip sonore de validation est mis 4 Pour sortir de la programmation tapez B Deux bips sonores sont mis pour confirmer le retour au mode normal de fonctionnement 4 bips indiquent une erreur de saisie Remise z ro du code maitre En fonctionnement normal positionnez un cavalier en P2 Attendre 1 seconde et enlevez le cavalier Un bip est mis Le code maitre est de nouveau 1234 5 en 5 termes ou 12 3 4 en 4 termes I Changement du code d entr e par l utilisateur L autorisation de changement de code par l utilisateur est d termin e par le positionne ment du cavalier P3 Otez le cavalier pour interdire le changement de code et placez le cavalier pour autoriser le changement 1 Composez le code utilis actuellement Le relais d ouverture est command Un bip sonore est mis 2 Tapez imm diatement les 2 termes du code de modification Relais 1 la premi re utilisation A et B Relais 2 la premi re utilisation 1 et 3 Relais 3 la premi re utili